hh6/8/10 instructions -ledarchitectural high lumen led downlight flangeless trim installation...

Post on 06-Aug-2020

1 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

HH6/8/10-LED INSTRUCTIONS

SAFETY INSTRUCTIONS1. Do not use outdoors. 2. Equipment should be mounted securely in locations and at heights where it will not be readily subjectedto tampering by unauthorized personnel. 3. Do not mount near gas or electric heaters. 4. Cap unused wires with enclosed wire nutsor other approved method. 5. Do not use this equipment for anything other than its intended use. 6. The use of accessory

equipment not recommended by the manufacturer will void product listing and warranty and may cause an unsafe condition. 7. Use caution when servicing batteries. 8. Any service on this equipment should be performed by qualified personnel only. 9. Make sure wire terminations are secure and leads are properly tucked in appropriate wire channels. CONSULT A QUALIFIED ELECTRICIAN BEFORE INSTALLING

PAGE 1 OF 4

Catalog# HH6-LED-900L/1200L/1500L/2000L/3000L/4000LO.R.-Revision A: 4/27/20

323-888-1973 techsupport@iuseelite.com www.iuseelite.com

Caution: Disconnect AC power before servicing and installation.All electrical connections must be in accordance withNEC/CEC or your local code.

Emergency Driver Mounting

Standard Emergency Mounting Stud Mounting T-Bar Box Hanger

HH6IC-LED

*Insulation Contact is good up to 2000L

Architectural High Lumen LED Downlight

EMG LED Driver

Test Switch J-Box

(J-Box not provided)

Regular

LED Driver

LED Driver Mounting

Insulation

HH6/8/10-LED INSTRUCTIONSPAGE 2 OF 4

Catalog# HH6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000LO.R.-Revision B: 4/27/20

323-888-1973 techsupport@iuseelite.com www.iuseelite.com

Emergency LED Driver Bracket Mounting

House Framing Mounting

Joist Mounting

Luminaire 1

T-Bar Mounting

Luminaire 1

Position housing and then secure frame to structure.Adjust it if needed using the self-adjustable locks.

Position housing and then secure frame to structure.Adjust it if needed using the self-adjustable locks.

Self Self Adjustable Locks

1

Integral Test Switch Remote Mount Test Switch

Architectural High Lumen LED Downlight

Emergency Test Switch

1 1

2

SupportBracket

Screw in the Support BracketsMount the Driver Mounting Bracket/J-Box

into the Support Brackets

Driver Mounting Bracket/J-Box

Self-Adjustable Locks

HH6/8/10-LED INSTRUCTIONSPAGE 3 OF 4

Catalog# HH6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000LO.R.-Revision B: 4/27/20

323-888-1973 techsupport@iuseelite.com www.iuseelite.com

Flange Trim Installation

Luminaire 2

6 7

Insert the flange trim by squeezing v-spring into the bracket slot

END OF FLANGE TRIM

Install the drywall ceiling and using a router make the hole using the

inside of the rough-in frame as guide

Push up the reflector then rotate it counter clockwise to secure the twist screws into reflector slots. Tighten

both twist screws.

Architectural High Lumen LED Downlight

0-10V Dimming Wiring

Connect all electrical connections.

3 4 5

Place the heatsink momentary on the frame while drywall is install.

2

Wiring Diagram

Luminaire 1

To Additional Luminaires

HH6/8/10-LED INSTRUCTIONSPAGE 4 of 4

Catalog# HH6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000LO.R.-Revision B: 4/27/20

323-888-1973 techsupport@iuseelite.com www.iuseelite.com

7

9 10

Insert the flangeless trim by squeezing v-spring into the bracket slot

END OF FLANGELESS TRIM

Apply plaster or spackle over mesh ring. Oncedry sand surface for a finished look.

5

6

Install the drywall ceiling and usinga router make the hole using the

inside of the rough-in frame as guideInsert the mesh ring. Friction blades

will hold it in place.

Apply plaster or spackle over mesh ring. Once dry sand surface for a

finished look.

InsertCover

3 4

8

Place the heatsink momentary on the frame while drywall is install.

Push up the reflector then rotate it counter clockwise to secure the twist screws into reflector slots. Tighten

both twist screws.

Architectural High Lumen LED Downlight

Flangeless Trim Installation (Continuation)

Insert

Cover

HH6/8/10-LED INSTRUCTIONS

SAFETY INSTRUCTIONS1. Do not use outdoors. 2. Equipment should be mounted securely in locations and at heights where it will not be readily subjectedto tampering by unauthorized personnel. 3. Do not mount near gas or electric heaters. 4. Cap unused wires with enclosed wire nutsor other approved method. 5. Do not use this equipment for anything other than its intended use. 6. The use of accessory

equipment not recommended by the manufacturer will void product listing and warranty and may cause an unsafe condition. 7. Use caution when servicing batteries. 8. Any service on this equipment should be performed by qualified personnel only. 9. Make sure wire terminations are secure and leads are properly tucked in appropriate wire channels. CONSULT A QUALIFIED ELECTRICIAN BEFORE INSTALLING

PAGE 1 OF 4

323-888-1973 techsupport@iuseelite.com www.iuseelite.com

Caution: Disconnect AC power before servicing and installation.All electrical connections must be in accordance withNEC/CEC or your local code.

Emergency Driver Mounting

Standard Emergency Mounting Stud Mounting T-Bar Box Hanger

HH6-LED-6000L HH6-LED-8000L

LED Driver

LED Driver

6000L/8000L High Lumen LED Downlight

EMG LED Driver

Test Switch J-Box

(J-Box not provided)

Regular

LED Driver

LED Driver Mounting

Catalog# HH6/8/10-LED-6000L/8000LO.R.-Revision A: 4/22/20

HH6/8/10-LED INSTRUCTIONSPAGE 2 OF 4

323-888-1973 techsupport@iuseelite.com www.iuseelite.com

Emergency Or Regular LED Driver Bracket Mounting

House Framing Mounting

Joist Mounting

Luminaire 1

T-Bar Mounting

Luminaire 1

Position housing and then secure frame to structure.Adjust it if needed using the self-adjustable locks.

Position housing and then secure frame to structure.Adjust it if needed using the self-adjustable locks.

1

Integral Test Switch Remote Mount Test Switch

6000L/8000L High Lumen LED Downlight

Emergency Test Switch

1 1

2

SupportBracket

Screw in the Support BracketsMount the Driver Mounting Bracket/J-Box

into the Support Brackets

Driver Mounting Bracket/J-Box

Self-AdjustableLocks

Catalog# HH6/8/10-LED-6000L/8000LO.R.-Revision A: 4/22/20

HH6/8/10-LED INSTRUCTIONSPAGE 3 OF 4

323-888-1973 techsupport@iuseelite.com www.iuseelite.com

Flange Trim Installation

Flangeless Trim Installation

Luminaire 2

6000L/8000L High Lumen LED Downlight

0-10V Dimming Wiring

Connect all electrical connections.

3 4 5

3 4 5

Install the drywall ceiling and using a router make the hole using the

inside of the rough-in frame as guide

Insert the flange trim by squeezing v-spring into the bracket slot

END OF FLANGE TRIM

Install the drywall ceiling and using a router make the hole using the

inside of the rough-in frame as guide

Insert the mesh ring. Friction blades will hold it in place.

Apply plaster or spackle over mesh ring. Once dry sand surface for a

finished look.

2

Wiring Diagram

InsertCover

Luminaire 1

To Additional Luminaires

Catalog# HH6/8/10-LED-6000L/8000LO.R.-Revision A: 4/22/20

HH6/8/10-LED INSTRUCTIONSPAGE 4 OF 4

Catalog# HH6/8/10-LED-6000L/8000LO.R.-Revision A: 4/22/20

323-888-1973 techsupport@iuseelite.com www.iuseelite.com

6 7 8

Insert the flangeless trim by squeezing v-spring into the bracket slot

END OF FLANGELESS TRIMApply plaster or spackle over mesh ring. Once

dry sand surface for a finished look.

6000L/8000L High Lumen LED Downlight

Flangeless Trim Installation (Continuation)

Insert

Cover

top related