grundfos data booklet - building 3d content · 3 general description ch, chn introduction the...
Post on 29-Apr-2018
238 Views
Preview:
TRANSCRIPT
GRUNDFOS DATA BOOKLET
CH, CHN
Horizontal multistage end-suction pumps50/60 Hz
2
Contents
General descriptionIntroduction 3Applications 3Pumped liquids 3Operating conditions 3Performance range 4
IdentificationType key 5
ConstructionPump 6Motor 6CH, CHN 2-50 7CH, CHN 4-60 8CH 8-50 9CH 12-50 10Material specification 11
Curve chartsCurve conditions 12How to read the curve charts 13
Performance curves/technical dataCH, CHN 50 Hz 14CH, CHN 2 14CH, CHN 4 16CH 8 18CH 12 20CH, CHN 60 Hz 22CH, CHN 2 22CH, CHN 4 26CH 8 30CH 12 32
Pumped liquidsPumped liquids 34List of pumped liquids 34
VariantsLists of variants 36Motors 36Shaft seals 36Connections and other variants 36Certificates and nameplates 36Pumps 36
Further product documentationWebCAPS 37WinCAPS 38
CH, CHNGeneral description
IntroductionThe Grundfos CH and CHN pumps are non-self-priming, horizontal, multistage centrifugal pumps.
Pump and motor are integrated in a compact and user-friendly design fittet to a base plate making the pumps suitable for installation in compact systems.
CH and CHN pumps have many incorporated advan-tages such as those mentioned below.
Worldwide usage • Different certificates and approvals like UL/CSA for
America and Canada.• Different voltage and frequency combinations.• State-of-the-art shaft seal materials (silicon carbide
SiC-G) offering these benefits:- high wear resistance and long operating times- reduced risk of sticking if the liquid contains glycol- improved dry-running properties due to the graphite content of the SiC.
Electro-coated cast iron parts• High corrosion resistance.• Better efficiency because of smooth surfaces.
Customized solutionsSee “List of Variants” on page 36.
• Motor adaptation. • Pump body modifications.
MaterialsCH: Chambers and all moving parts in contact with the pumped liquid are made of stainless steel. Discharge chamber, suction chamber and base plate are painted non-gloss black.
CHN: Discharge chamber, suction chamber, base plate and all parts in contact with the pumped liquid are made of stainless steel.
The pump is CE-marked.
ApplicationsThe CH and CHN pumps are designed for small domestic and industrial systems.
Applications• Liquid transfer and circulation of liquids within light
industry and farming• Pressure boosting in single-pump and multi-pump
booster systems• Domestic water supply• Cooling systems• Air-conditioning systems.
Pumped liquidsCHThin, clean, non-aggressive and non-explosive liquids without solid particles or fibres.
CHNThin, clean, slightly aggressive and non-explosive liquids without solid particles or fibres.
Operating conditions
*Lower temperatures are possible. See Lists of variants on page 36.
The maximum operating pressure depends on the temperature of the pumped liquid. See the table.
TM03
593
9 44
02
Liquid temperature range: *0 °C to +90 °C. Max. ambient temperature: +55 °C.
Max. operating pressure 1 MPa (10 bar) 0.6 MPa (6 bar)CH 2, CHN 2CH 4, CHN 4 0 °C to +40 °C +41 °C to +90 °C
CH 8CH 12 0 °C to +55 °C +56 °C to +90 °C
Min. inlet pressure: According to the NPSH curve plus a safety margin of 0.5 m.
Max. inlet pressure: Limited by the max. operating pressure.
3
4
General description CH, CHN
Performance rangeCH, CHN, 50 Hz
CH, CHN, 60 Hz
TM02
123
9 39
02
1 2 3 4 5 6 7 8 9 10 11 12 13 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
H[m]
0
100
200
300
400
500
p[kPa]
CH, CHN50 Hz
ISO 9906 Annex A
CH 12CH 8CH 4CH 2CHN 2 CHN 4
TM02
124
0 39
02
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
H[m]
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [l/s]
0
100
200
300
400
500
600
700
800
p[kPa]
CH, CHN60 Hz
ISO 9906 Annex A
CH 2 CH 4 CH 8 CH 12
CHN 2 CHN 4
5
Type keyIdentification
Type key
Codes for physical dimensions
Codes for materials
Example CH(N) 4 -30 A W -A -CVBE
Type range
Rated flow rate [m³/h]
Max. discharge pressure [m]
Code for pump version
Code for physical dimensions
Code for materials, excluding plastic and rubber parts
Code for shaft seal
B: NPT pipe connectionN: Different connection diametersW: Whitworth thread, Rp ISO 7/1O: Outside thread.
A: Basic versionI: Stainless materialsX: Special version.
6
CH, CHNConstruction
PumpThe CH, CHN pumps are non-self-priming, horizontal, multistage centrifugal pumps with mechanical shaft seal and through-going pump-motor shaft. The pumps have axial suction port and radial discharge port and are mounted on a base plate. All movable parts in contact with the pumped liquid are made of stainless steel.
EPDM or FKM O-rings are available as standard. See pipe connections in the table.
MotorThe pump is fitted with a TEFC (totally enclosed, fan-cooled), squirrel-cage Grundfos motor.
The single-phase motors are supplied with a built-in thermal relay to IEC 34-11, TP 211 (slow overload as well as locked rotor). The motors require no further motor protection.
The three-phase motors do not incorporate thermal protection and therefore require external motor protection in accordance with local regulations.
The sound pressure level of the pump is lower than the limiting values stated in the EC Council Directive 98/37/EC relating to machinery.
Frequency converter operationMost three-phase motors can be operated with a frequency converter. See Lists of variants on page 36.
Connections CH 2, CHN 2
CH 4, CHN 4 CH 8 CH 12
Axial suction port Rp 1 Rp 1Rp 1 1/4 Rp 1 1/2 Rp 1 1/2
Radial discharge port Rp 1 Rp 1 Rp 1 1/4 Rp 1 1/2Drain hole, priming hole Rp 3/8 Rp 3/8 Rp 1/2 Rp 1/2
Rated speed: 50 Hz, 2900 min-1
60 Hz, 3400 min-1
Enclosure class: IP 54Insulation class: FStandard voltages: 1 x 220-240 V, 50 Hz
3 x 220-240/380-415 V, 50 Hz1 x 115/230 V, 60 Hz3 x 208-230/440-480 V, 60 Hz3 x 575 V, 60 Hz
Voltage tolerance: +6 %/–10 %Sound-pressure level: ≤ 70 dB (A)
Construction CH, CHN
CH, CHN 2-50Sectional drawing
Fig. 1 CH, CHN 2-50 with MG 71 motor
Components
TM03
203
9 35
0465 45
4
28g5628
6237
1551532
172
154
158
151
159
156
105 64 49
164
164a
79
66 67
25
65
45
25
6
150a
Pos. Component Pos. Component Pos. Component2 Discharge chamber 56 Base plate 151 Fan cover4 Chamber 62 Stop ring 153,154 Ball bearing6 Suction chamber 64 Spacing pipe 155 Bearing cover plate
25 Plug 65 Retainer for neck ring 156 Fan28 Screw 66 Clamp 158 Corrugated spring
28g Hexagon head screw 67 Lock nut 159 O-ring37 Gasket 79 Diverting disc 164 Terminal box cover45 Neck ring 105 Shaft seal 164a Terminal box49 Impeller 150a Stator housing 172 Shaft
7
8
Construction CH, CHN
CH, CHN 4-60Sectional drawing
Fig. 2 CH, CHN 4-60 with MG 80 motor
Components
TM00
660
9 49
00
4
28g5628
3762 66 67
1551532
172
154
158
151
159
156
105 64 49
25
164
164a
47a4a
64a79
25
6
150a
Pos. Component Pos. Component Pos. Component2 Discharge chamber 56 Base plate 153,154 Ball bearing4 Chamber 62 Stop ring 155 Bearing cover plate
4a Chamber with bearing 64 Spacing pipe 156 Fan6 Suction chamber 64a Spacing pipe 158 Corrugated spring
25 Plug 66 Clamp 159 O-ring28 Screw 67 Lock nut 164 Terminal box cover
28g Hexagon head screw 79 Diverting disc 164a Terminal box37 Gasket 105 Shaft seal 172 Shaft
47a Bearing 150a Stator housing49 Impeller 151 Fan cover
Construction CH, CHN
CH 8-50Sectional drawing
Fig. 3 CH 8-50 with MG 80 motor
Components
TM03
203
6 35
05
37a172a154
151
156
150a157158 164 164a
79
105 49 49a 37
153 155 192 26 64 6645193 65
4
19141a 67
25
65
45
25
6
1a41
2
Pos. Component Pos. Component Pos. Component1a Pump housing 45 Neck ring 151 Fan cover4 Chamber 49 Impeller 153,154 Ball bearing6 Suction chamber 49a Impeller 155 Bearing cover plate
25 Plug 56 Base plate 156 Fan26 Staybolt 64 Spacing pipe 158 Corrugated spring28 Screw 65 Retainer for neck ring 159 O-ring
28g Hexagon head screw 66 Clamp 164 Terminal box cover28h Serrated lock washer 67 Lock nut 164a Terminal box37 Gasket 79 Diverting disc 172 Shaft
37a Gasket 105 Shaft seal41 Bearing plate 150a Stator housing
9
10
Construction CH, CHN
CH 12-50Sectional drawing
Fig. 4 CH 12-50 with MG 90 motor
Components
TM03
203
7 35
05
37a172a157
151
154159a156 164 153 105 49 49a 37
155 192 45193 65
4
156a158
79 191181 150a 41a 26 64 66 67
25
65
45
25
6
1a41
2
Pos. Component Pos. Component Pos. Component1a Pump housing 45 Neck ring 151 Fan cover4 Chamber 49 Impeller 153,154 Ball bearing6 Suction chamber 49a Impeller 155 Bearing cover plate
25 Plug 56 Base plate 156 Fan26 Staybolt 64 Spacing pipe 156a Non-drive end shield28 Screw 65 Retainer for neck ring 157a Lip seal
28g Hexagon head screw 66 Clamp 158 Corrugated spring28h Serrated lock washer 67 Lock nut 159 O-ring37 Gasket 79 Diverting disc 164 Terminal box cover
37a Gasket 105 Shaft seal 172 Shaft41 Bearing plate 150a Stator housing 181 Staybolt
Construction CH, CHN
Material specification
Pos. Description MaterialCH CHN
DIN W.-Nr. ISO/AISI/ASTM DIN W.-Nr. ISO/AISI/ASTM105 Shaft seal
Motor parts62 Stop ring Stainless steel 1.4401 AISI 316 1.4401 AISI 316
150 Stator housing complete with terminal box
Silumin/composite (MG 71 and MG 80)Silumin (MG 90)
150a Stator housing Silumin/composite (MG 71 and MG 80)Silumin (MG 90)
151 Fan cover Steel (MG 71 and MG 80)Composite PBT/PC (MG 90) 1.0330.3 1.0330.3
153, 154 Ball bearing
155 Bearing cover plate Stainless steel 1.4301 AISI 304 1.4301 AISI 304156 Fan Composite PA 66 30 % GF
156a Non-drive end shield (MG 90) Silumin157a Lip seal (MG 90)158 Corrugated spring159 O-ring NBR rubber
159a Gasket164 Terminal box cover
164a Terminal box
172 Pump shaft:Motor shaft:
Stainless steelSteel
1.40571.0531 AISI 431 1.4057
1.0531 AISI 431
172a Shaft, complete Stainless steel/steel 1.4057/1.0531 AISI 431 1.4057
1.0531 AISI 431
181 Staybolt (only MG 90) SteelPump parts
1a Pump housing2 Discharge chamber Cast iron/stainless steel 0.6020 ASTM 30 B 1.43084 Chamber Stainless steel 1.4301 AISI 304 1.4301 AISI 304
4a Chamber with bearing (CH 4)Stainless steel + aluminium oxide Al2O3 (ceramic) 1.4301 AISI 304 1.4301 AISI 304
6 Suction chamber, complete Cast iron/stainless steel 0.6020 ASTM 30 B 1.430825 Plug Free-cutting steel/stainless steel 1.0718 1.4301 AISI 30426 Staybolt Galvanized steel28 Screw
28g Hexagon head screw28h Serrated lock washer37, 37a Gasket Synthetic-fibre-reinforced rubber (NBR)
41 Bearing plate45 Neck ring PTFE
47a Bearing (shaft) (CH 4-60) Chromium-nickel-molybdenum-cemented tungsten carbide
49
Impeller CH 8 and 12: ∅130 mmCH, CHN 4: ∅95 mmCH, CHN 2: ∅90 mm
Stainless steel 1.4301 AISI 304 1.4301 AISI 304
49a Impeller CH 8 and 12: ∅98 mm Stainless steel 1.4301 AISI 304 1.4301 AISI 30456 Base plate Iron/stainless steel 1.0330.3 1.4301 AISI 30464, 64a Spacing pipe Stainless steel 1.4401 AISI 316 1.4401 AISI 316
65 Retainer for neck ring Stainless steel 1.4301 AISI 304 1.4301 AISI 30466 Clamp Stainless steel 1.4401 AISI 316 1.4401 AISI 31667 Lock nut Stainless steel 1.4301 AISI 304 1.4301 AISI 30479 Diverting disc NR rubber
11
12
CH, CHNCurve charts
Curve conditionsThe guidelines below apply to the curves on the following pages.
• Tolerances according to ISO 9906, Annex A.• The bold curves state the recommended
performance range.• The thin curves are only intended as a guide.• The curves must not be used as guarantee curves.• All curves are based on measurements at:• 1 x 230 V, 50 Hz• 3 x 400 V, 50 Hz• 1 x 220 V, 60 Hz• 3 x 380 V, 60 Hz.• When the motor is running at the lowest or highest
rated voltage, the pump performance will usually vary by ± 0.5 - 1.0 m at a given duty point.
• Specific minimum performance requirements necessitate individual measurements.
• The measurements have been made with airless water at a temperature of 20 °C (~70 °F).
• The conversion between head H (m) and pressure p (kPa) applies to a water density of ρ = 1000 kg/m3.
• The curves apply to a kinematic viscosity of υ = 1 mm2/s(1 cSt)
Curve charts CH, CHN
How to read the curve chartsCurves
QH: Pump performance at actual speed.P2: Pump input power.Eta 1: Total efficiency, i.e. pump with motor, is shown
in the curve charts as Eta 1.NPSH: Average values for all variants shown in
chart 1. When sizing, make a safety allowance of at least 0.5 m.
TM03
845
6 16
070.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
H[m]
0.0 0.2 0.4 0.6 0.8 1.0 Q [l/s]
0
100
200
300
400
500
p[kPa] CH 2, CHN 2
50 HzISO 9906 Annex A
CH(N) 2-20
CH(N) 2-30
CH(N) 2-40
CH(N) 2-50
CH(N) 2-60
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
0.0
0.1
0.2
0.3
0.4
0.5
P2[kW]
-20-30-40-50
-60
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
0
1
2
3
4
5
NPSH[m]
0
10
20
30
40
p[kPa]
0
10
20
30
40
50[%]Eta
Eta 1
NPSH
Pump type
Total pump head H = Htotal
The power curve shows the pump input power [P2]
The NPSH curve is an average curve for all variants shown. When sizing the pumps, add a safety margin of at least 0.5 m.
QH curve for the individual pump. The bold curve shows the recommended performance range.
13
14
Performance curves/technical data
CH, CHN 50 Hz
CH, CHN 2
TM03
845
6 16
07
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
H[m]
0.0 0.2 0.4 0.6 0.8 1.0 Q [l/s]
0
100
200
300
400
500
p[kPa] CH 2, CHN 2
50 HzISO 9906 Annex A
CH(N) 2-20
CH(N) 2-30
CH(N) 2-40
CH(N) 2-50
CH(N) 2-60
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
0.0
0.1
0.2
0.3
0.4
0.5
P2[kW]
-20-30-40-50
-60
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
0
1
2
3
4
5
NPSH[m]
0
10
20
30
40
p[kPa]
0
10
20
30
40
50[%]Eta
Eta 1
NPSH
CH 2, CHN 250 Hz
CH 2, CHN 250 HzTechnical data
Dimensions
Weights
Electrical dataTM
00 1
491
4900
Fig. 5 Dimensional sketches, CH, CHN 2 and 4 with MG 71/80 motor
Rp 1
CH 4 Rp 1 + Rp 1 1/4CH 2 Rp 1 Rp 3/8
Rp 3/8
L4
H
L1
160L3
138L2
ø8.5 90
155
130
108
B2
B1
CH, CHN 2 Rp 1CH, CHN 4 Rp 1 + Rp 1¼
Voltage[V]
Frequency[Hz] Pump type Motor type L1
[mm]L2
[mm]L3
[mm]L4
[mm]B1
[mm]B2
[mm]H
[mm]
1 x 220-240 50
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 71MG 71MG 71
304322340358376
7492110128146
638199117135
99117135154172
146146146146146
115115115115115
205205205205205
3 x 220-240/380-415 50
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 71MG 71MG 71
304322340358376
7492110128146
638199117135
99117135154172
146146146146146
110110110110110
200200200200200
3 x 200-220/346-3803 x 200-230/346-400
5060
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 80MG 80MG 80
304322380398416
7492110128146
638199117135
99117135154172
141.5141.5141.5141.5141.5
110110110110110
200200200200200
Pump typeSingle-phase Three-phase
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
9.69.6
10.911.311.6
11.411.411.512.012.3
0.01870.01870.01870.02350.0235
11.110.711.011.511.8
11.811.611.712.212.5
0.01870.01870.01870.02350.0235
Voltage[V]
Frequency[Hz] Pump type Motor type I1/1
[A]Ist[A]
P1[W]
P2[W]
C[µF/V]
1 x 220-240 50
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 71MG 71MG 71
2.22.32.62.93.7
10.510.510.510.513
420480570680800
205280370450560
10/40010/40010/40010/40016/400
3 x 220-240/380-415 50
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 71MG 71MG 71
1.6/0.91.7/1
1.9/1.12.35/1.252.55/1.35
11.4/6.611.4/6.611.4/6.611.4/6.611.4/6.6
380460570800820
230300400560580
3 x 200-220/346-380** 50
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 80MG 80MG 80
2.5/1.62.5/1.63.3/2.13.4/2.14.0/2.3
16.2/14.316.2/14.321.6/18.821.6/18.830.8/30.8
370450590690790
230300400490600
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.
15
16
CH 4, CHN 450 HzPerformance curves
CH, CHN 4
TM03
845
7 16
07
0 1 2 3 4 5 6 7 8 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
H[m]
0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]
0
100
200
300
400
500
p[kPa]
CH 4, CHN 450 Hz
ISO 9906 Annex A
CH(N) 4-20
CH(N) 4-30
CH(N) 4-40
CH(N) 4-50
CH(N) 4-60
0 1 2 3 4 5 6 7 8 Q [m³/h]
0.0
0.4
0.8
1.2
P2[kW]
-60-50
-40-30-20
0 1 2 3 4 5 6 7 8 Q [m³/h]
0
1
2
3
NPSH[m]
0
10
20
30
p[kPa]
0
10
20
30
[%]Eta
Eta 1
NPSH
CH 4, CHN 450 HzTechnical data
Dimensions
Weights
Electrical data
TM00
149
1 49
00
Fig. 6 Dimensional sketches, CH, CHN 2 and 4 with MG 71/80 motor
Rp 1
CH 4 Rp 1 + Rp 1 1/4CH 2 Rp 1 Rp 3/8
Rp 3/8
L4
H
L1
160L3
138L2
ø8.5 90
155
130
108
B2
B1
CH, CHN 2 Rp 1CH, CHN 4 Rp 1 + Rp 1¼
Voltage[V]
Frequency[Hz] Pump type Motor
typeL1
[mm]L2
[mm]L3
[mm]L4
[mm]B1
[mm]B2
[mm]H
[mm]
1 x 220-240 50
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50CH, CHN 4-60
MG 71MG 71MG 71MG 80MG 80
314342370438466
83110137164191
7299
126153180
108135163190217
146146146
141.5141.5
115115115135135
205205205225225
3 x 220-240/380-415 50
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50CH, CHN 4-60
MG 71MG 71MG 71MG 80MG 80
314342370438466
83110137164191
7299
126153180
108135163190217
146146146
141.5141.5
115110110110110
200200200200200
3 x 200-220/346-3803 x 200-230/346-400
5060
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40
MG 71MG 80MG 80
314382410
83110137
7299
126
108135163
141.5141.5141.5
110110110
200200200
Pump typeSingle-phase Three-phase
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50CH, CHN 4-60
9.510.912.316
15.2
10.111.613.017.716.6
0.01870.01870.02350.02350.0235
9.611.012.514.214.9
10.311.713.214.916.3
0.01870.01870.02350.04220.0422
Voltage[V]
Frequency[Hz] Pump type Motor type I1/1
[A]Ist[A]
P1[W]
P2[W]
C[µF/V]
1 x 220-240 50
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50CH, CHN 4-60
MG 71MG 71MG 71MG 80MG 80
2.33.93.95.86.7
1121212929
540840116013001460
345480690920
1050
16/40025/40025/40030/40050/400
3 x 220-240/380-415 50
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50CH, CHN 4-60
MG 71MG 71MG 71MG 80MG 80
1.9/1.02.3/1.32.8/1.64.0/2.3 4.4/2.5
11.4/6.611.4/6.611.4/6.6
26.0/15.026.0/15.0
560820965
13201510
390540660
10001170
3 x 200-220/346-380** 50CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40
MG 71MG 80MG 80
2.6/1.53.5/2.04.2/2.4
16.2/14.321.6/18.830.8/30.8
544808966
390565771
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.
17
18
CH 850 HzPerformance curves
CH 8
TM03
845
8 16
07
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
60
H[m]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [l/s]
0
100
200
300
400
500
600
p[kPa]
CH 850 Hz
ISO 9906 Annex A
CH 8-20
CH 8-30
CH 8-40
CH 8-50
CH 8-60
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0.0
0.4
0.8
1.2
1.6
P2[kW]
-60-50
-40-30
-20
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0
1
2
3
4
NPSH[m]
0
10
20
30
40
p[kPa]
0
10
20
30
40[%]Eta
Eta 1
NPSH
CH 850 HzTechnical data
Dimensions
Weights
Electrical dataTM
00 1
189
3505
/TM
00 1
490
3505
Fig. 7 Dimensional sketches, CH 8
Rp 1/2
Rp 1/2Rp 1 1/2
CH 12 Rp 1 1/2CH 8 Rp 1 1/4
L4
240
ø8.5
L1
L3
L2
160
138
110
188
130
108
B2
B1CH 8 Rp 1 1/4
Rp 1 1/2
Rp 1/2
Rp 1/2
CH 12 Rp 1 1/2L4
240
ø8.5
L1
L3
L2
160
138
110
188
130
108
B1
MG 80 motor MG 90 motor
Voltage[V]
Frequency[Hz] Pump type Motor type L1
[mm]L2
[mm]L3
[mm]L4
[mm]B1
[mm]B2
[mm]
1 x 220-240 50
CH 8-20CH 8-30CH 8-40CH 8-50CH 8-60
MG 71MG 80MG 80MG 90MG 90
311381381459459
699999
129129
588888118118
77107107137137
177177177182182
109109109
3 x 220-240/380-415 50
CH 8-20CH 8-30CH 8-40CH 8-50CH 8-60
MG 71MG 80MG 80MG 80MG 90
311381381411459
699999
129129
588888118118
77107107137137
177177177177182
109109109109
3 x 200/3463 x 200-220/346-400
5060
CH 8-20CH 8-25CH 8-30CH 8-40
MG 71MG 80MG 80MG 80
311381381381
69999999
58888888
77107107107
177177177177
109109109109
3 x 200/346 50 CH 8-50CH 8-60
MG 80MG 80
411411
129129
118118
137137
177177
109109
Pump typeSingle-phase Three-phase
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
CH 8-20CH 8-25CH 8-30CH 8-40CH 8-50CH 8-60
15-
1719
28.828.8
17-
1921
31.631.6
0.0422-
0.04220.04220.04220.0422
15-
17192025
17-
19212227
0.0422-
0.04220.04220.04220.0422
Voltage[V]
Frequency[Hz] Pump type Motor type I1/1
[A]Ist[A]
P1[W]
P2[W]
C[µF/V]
1 x 220-240 50
CH 8-20CH 8-30CH 8-40CH 8-50CH 8-60
MG 71MG 80MG 80MG 90MG 90
3.24.35.67.88.5
1113
26.52929
730970
133017401930
480740940
13101460
16/40020/40025/40030/40030/400
3 x 220-240/380-415 50
CH 8-20CH 8-30CH 8-40CH 8-50CH 8-60
MG 71MG 80MG 80MG 80MG 90
2.1/1.23.4/2.04.7/2.75.2/3.05.9/3.4
11.4/6.618.2/10.527.5/1627.5/1645/26
6501030129016501930
480790
102512901560
3 x 200/346** 50
CH 8-20CH 8-25CH 8-30CH 8-40
MG 71MG 80MG 80MG 80
3.4/2.04.1/2.44.0/2.34.5/2.5
16.2/9.421.6/12.430.0/17.430.0/17.4
714891
10001720
517696830
1290
3 x 200/346 50 CH 8-50CH 8-60
MG 80MG 80
5.7/3.36.0/3.5
30.0/17.430.0/17.4
17201850
12901370
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.
19
20
CH 1250 HzPerformance curves
CH 12
TM03
845
9 16
07
0 2 4 6 8 10 12 14 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
60
H[m]
0 1 2 3 4 Q [l/s]
0
100
200
300
400
500
600
p[kPa]
CH 1250 Hz
ISO 9906 Annex A
CH 12-20
CH 12-30
CH 12-40
CH 12-50
CH 12-60
0 2 4 6 8 10 12 14 Q [m³/h]
0.0
0.5
1.0
1.5
2.0
2.5
P2[kW]
-20
-30-40-50
-60
0 2 4 6 8 10 12 14 Q [m³/h]
0
1
2
3
4
5
NPSH[m]
0
10
20
30
40
p[kPa]
0
10
20
30
40
50[%]Eta
Eta 1
NPSH
CH 1250 HzTechnical data
Dimensions
Weights
Electrical dataTM
00 1
189
3505
/TM
00 1
490
3505
Fig. 8 Dimensional sketches, CH 12
Rp 1/2
Rp 1/2Rp 1 1/2
CH 12 Rp 1 1/2CH 8 Rp 1 1/4
L4
240
ø8.5
L1
L3
L2
160
138
110
188
130
108
B2
B1CH 8 Rp 1 1/4
Rp 1 1/2
Rp 1/2
Rp 1/2
CH 12 Rp 1 1/2L4
240
ø8.5
L1
L3
L2
160
138
110
188
130
108
B1
MG 80 motor MG 90 motor
Voltage[V]
Frequency[Hz] Pump type Motor type L1
[mm]L2
[mm]L3
[mm]L4
[mm]B1
[mm]B2
[mm]
1 x 220-240 50
CH 12-20CH 12-30CH 12-40CH 12-50
MG 80MG 80MG 90MG 90
351381429459
699999
129
588888118
77107107137
177177182182
109109
3 x 220-240/380-415 50
CH 12-20CH 12-30CH 12-40CH 12-50CH 12-60
MG 80MG 80MG 90MG 90MG 90
351381429459459
699999
129129
588888118118
77107107137137
177177182182182
109109
3 x 200/3463 x 200-220/346-380
5060
CH 12-10CH 12-20CH 12-30CH 12-40
MG 71MG 80MG 90MG 90
311351429429
69699999
58588888
7777
107107
177177182182
109109
3 x 200/346 50 CH 12-50CH 12-60
MG 90MG 90
459459
129129
118118
137137
182182
110110
Pump typeSingle-phase Three-phase
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
CH 12-10CH 12-20CH 12-30CH 12-40CH 12-50CH 12-60
-17192627-
-19212829-
-0.04220.04220.04220.0422
-
-1719242727
-1921262929
-0.04220.04220.04220.04220.0422
Voltage[V]
Frequency[Hz] Pump type Motor type I1/1
[A]Ist[A]
P1[W]
P2[W]
C[µF/V]
1 x 220-240 50
CH 12-20CH 12-30CH 12-40CH 12-50
MG 80MG 80MG 90MG 90
4.86.89.611.3
1326.74242
1060152021802560
710108016421630
20/40025/40050/40050/400
3 x 220-240/380-415 50
CH 12-20CH 12-30CH 12-40CH 12-50CH 12-60
MG 80MG 80MG 90MG 90MG 90
3.2/1.84.3/2.56.6/3.88.1/4.89.4/5.5
18.2/10.526.0/15.045.0/26.057.0/33.057.0/33.0
10301530220026903180
7901190177021502560
3 x 200/346** 50
CH 12-10CH 12-20CH 12-30CH 12-40
MG 71MG 80MG 90MG 90
3.3/1.93.1/1.87.0/4.09.9/5.7
3.3/1.93.1/1.87.0/4.09.9/5.7
550880
16001720
375670
12801290
3 x 200/346 50 CH 12-50CH 12-60
MG 90MG 90
8.5/4.911.4/6.5
8.5/4.911.4/6.5
26003500
22002700
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.
21
22
Performance curves
CH, CHN 60 Hz
CH, CHN 2
TM03
846
0 16
07
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
H[m]
0.0 0.2 0.4 0.6 0.8 1.0 Q [l/s]
0
100
200
300
400
500
600
700
p[kPa]
CH 2, CHN 260 Hz
ISO 9906 Annex A
CH(N) 2-20
CH(N) 2-30
CH(N) 2-40
CH(N) 2-50
CH(N) 2-60
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 Q [m³/h]
0.0
0.2
0.4
0.6
0.8
1.0
P2[kW]
-20-30
-40-50
-60
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 Q [m³/h]
0
2
4
6
8
NPSH[m]
0
20
40
60
80
p[kPa]
0
10
20
30
40[%]Eta
Eta 1
NPSH
CH 2, CHN 260 Hz
CH 2, CHN 260 HzTechnical data
Dimensions
Weights
TM00
149
1 49
00
Fig. 9 Dimensional sketches, CH, CHN 2 and 4 with MG 71/80 motor
Rp 1
CH 4 Rp 1 + Rp 1 1/4CH 2 Rp 1 Rp 3/8
Rp 3/8
L4
H
L1
160L3
138L2
ø8.5 90
155
130
108
B2
B1
CH, CHN 2 Rp 1CH, CHN 4 Rp 1 + Rp 1¼
Voltage[V]
Frequency[Hz] Pump type Motor type L1
[mm]L2
[mm]L3
[mm]L4
[mm]B1
[mm]B2
[mm]H
[mm]
1 x 1101 x 1271 x 110/220*1 x 220
60
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 80MG 80MG 80
304322380398416
7492110128146
638199117135
99117135154172
141.5141.5141.5141.5141.5
135135135135135
225225225225225
3 x 208-230/440-480 (USA)With cUL approval3 x 575 (Canada)With cUL approval
60
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
ML 71ML 71ML 71ML 71ML 80
304322382400417
7492110128146
638199117135
99117135154172
146146146146
141.5
110110110110115
200200200200200
1 x 115/230 (USA)With cUL approval 60
CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
ML 71ML 80ML 80ML 90
322381399416
92110128146
8199117135
117135154172
146141.5141.5141.5
145145145145
226226226226
3 x 200-220/346-380 (Japan)3 x 200-230/346-400 (Japan)
5060
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 80MG 80MG 80
304322380398416
7492110128146
638199117135
99117135154172
141.5141.5141.5141.5141.5
110110110110110
200200200200200
* No motor protection
Pump typeSingle-phase Three-phase
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
12.812.813
13.314.6
13.513.513.714
16.2
0.01870.01870.02350.02350.0235
11.111.111.311.512.0
11.811.811.912.513.0
0.01870.01870.01870.02350.0235
23
24
CH 2, CHN 260 HzTechnical data
Electrical data
Voltage[V]
Frequency[Hz] Pump type Motor type SF I1/1
[A]Ist[A]
P1[W]
P2[W]
Motor P2[HP]
C[µF/V]
1 x 110 60 CH, CHN 2-20CH, CHN 2-30CH, CHN 2-50
MG 71MG 71MG 80
6.68.711.2
2929
13.2
690880
1210
350450820
20/40020/40025/400
1 x 110/220* 60CH, CHN 2-20CH, CHN 2-30CH, CHN 2-50
MG 71MG 71MG 80
6/2.97/2.9
11.2/5.6
2929
13.2
680800
1210
360460820
20/40020/40025/400
1 x 127 60 CH, CHN 2-30CH, CHN 2-50
MG 71MG 80
5.98.9
2535
7301100
480800
20/40025/400
1 x 220 60
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 80MG 80MG 80
3.13.64.75.57.8
1515181821
530880
100012001300
320520670930950
20/40020/40025/40025/40025/400
3 x 208-230/440-480 (USA)With cUL approval 60
CH 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
ML 71ML 71ML 71ML 71ML 80
1.701.701.701.701.60
1.701.701.701.701.60
2.90/1.452.90/1.454.20/2.104.20/2.105.20/2.60
13.915.720.720.732.0
0.50.5
0.750.75
1
0.50.5
0.750.75
1
1 x 115/230 (USA)With cUL approval 60
CH 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
ML 71ML 71ML 80ML 80ML 80
1.601.601.501.501.50
1.601.601.501.501.50
9.00/4.509.00/4.5011.5/5.7011.5/5.7015.0/7.50
24.924.934.034.048.0
0.50.5
0.750.75
1
0.50.5
0.750.75
1
40/40040/40040/40040/40050/400
3 x 575 (Canada)With cUL approval 60
CH 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
ML 71ML 71ML 71ML 71ML 80
1.701.701.701.701.60
1.701.701.701.701.60
1.161.161.681.682.08
5.115.78.08.011.2
0.50.5
0.750.75
1
0.50.5
0.750.75
1
3 x 200-230/346-400** (Japan) 60
CH, CHN 2-20CH, CHN 2-30CH, CHN 2-40CH, CHN 2-50CH, CHN 2-60
MG 71MG 71MG 80MG 80MG 80
2/1.12.2/1.32.8/1.63.3/1.93.9/2.2
15.7/9.115.7/9.1
20.7/12.020.7/12.032/18.4
520670860
10001200
380510680820980
* No motor protection.** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.
25
26
CH 4, CHN 460 HzPerformance curves
CH, CHN 4
TM03
846
1 16
07
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
H[m]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [l/s]
0
100
200
300
400
500
p[kPa] CH 4, CHN 4
60 HzISO 9906 Annex A
CH(N) 4-20
CH(N) 4-30
CH(N) 4-40
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0.0
0.4
0.8
1.2
P2[kW]
-40-30-20
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0
1
2
3
4
NPSH[m]
0
10
20
30
40
p[kPa]
0
10
20
30
40[%]Eta
Eta 1
NPSH
CH 4, CHN 460 HzTechnical data
Dimensions
Weights
TM00
149
1 49
00
Fig. 10 Dimensional sketches, CH, CHN 2 and 4 with MG 71/80 motor
Rp 1
CH 4 Rp 1 + Rp 1 1/4CH 2 Rp 1 Rp 3/8
Rp 3/8
L4
H
L1
160L3
138L2
ø8.5 90
155
130
108
B2
B1
CH, CHN 2 Rp 1CH, CHN 4 Rp 1 + Rp 1¼
Voltage[V]
Frequency[Hz] Pump type Motor type L1
[mm]L2
[mm]L3
[mm]L4
[mm]B1
[mm]B2
[mm]H
[mm]1 x 110 1 x 110/220*1 x 1271 x 220
60CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40
MG 71MG 80MG 80
314382410
83110137
7299
126
108135163
141.5141.5141.5
135135135
225225225
3 x 208-230/440-480 (USA)With cUL approval 60
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50
ML 71ML 71ML 80ML 80
314382411439
83110137164
7299
126153
108135163190
146146
141.5141.5
110110115115
200200200200
1 x 115/230 (USA)With cUL approval 60
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50CH, CHN 4-60
ML 71ML 71ML 80ML 80ML 90
314342411439504
8383110137164
727299
126153
108108135163190
146146
141.5141.5191
110145145145132
226226226226205
3 x 575 (Canada)With cUL approval 60
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50CH, CHN 4-60
ML 71ML 71ML 71ML 80ML 80
314342370439467
8383110137164
727299
126153
108108135163190
146146146
141.5141.5
110110110115115
200200200200200
3 x 200-220/346-380 (Japan)3 x 200-230/346-400 (Japan)
5060
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40
MG 71MG 80MG 80
314382410
83110137
7299
126
108135163
141.5141.5141.5
110110110
200200200
* No motor protection
Pump typeSingle-phase Three-phase
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50CH, CHN 4-60
1213.414.2
--
12.714.115.2
--
0.01870.02350.0235
--
10.912.313.8
--
11.613.014.5
--
0.01870.02350.0235
--
27
28
CH 4, CHN 460 HzTechnical data
Electrical data
Voltage[V]
Frequency[Hz] Pump type Motor type SF I1/1
[A]Ist[A]
P1[W]
P2[W]
Motor P2[HP]
C[µF/V]
1 x 110 60CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40
MG 71MG 80MG 80
8.413.815.6
293662
95015001860
550970
1200
20/40025/40030/400
1 x 110/220* 60CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40
MG 71MG 80MG 80
8.8/5.913.8/7
16.0/8.1
29.0/15.036.0/18.062.0/32.0
98015201720
590920
1220
20/40025/40030/400
1 x 127 60CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40
MG 71MG 80MG 80
7.210.814
253550
92013601720
620890
1220
20/40025/40030/400
1 x 220 60CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40
MG 71MG 80MG 80
4.27.07.8
151832
95015001860
550970
1200
20/40025/40030/400
3 x 208-230/440-480 (USA)With cUL approval 60
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50
ML 71ML 71ML 80ML 80
1.701.701.601.47
1.701.701.601.47
2.90/1.454.20/2.105.20/2.606.90/3.50
15.720.733.942.0
0.50.751.01.5
0.50.751.01.5
1 x 115/230 (USA)With cUL approval 60
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50
ML 71ML 71ML 80ML 90
1.601.501.501.40
1.601.501.501.40
9.00/4.5011.5/5.7015.0/7.5021.5/10.7
24.934.033.933.9
0.50.751.01.5
0.50.751.01.5
40/40040/40050/40060/400
3 x 575 (Canada)With cUL approval 60
CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40CH, CHN 4-50
ML 71ML 71ML 80ML 80
1.701.701.601.47
1.701.701.601.47
1.161.682.082.80
5.18.011.215.3
0.50.751.01.5
0.50.751.01.5
3 x 200-230/346-400** (Japan) 60CH, CHN 4-20CH, CHN 4-30CH, CHN 4-40
MG 71MG 80MG 80
2.7/1.54.0/2.34.9/2.8
15.7/9.120.7/12.033.9/19.6
81112611526
616893
1202* No motor protection.**Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.
29
30
CH 860 HzPerformance curves
CH 8
TM03
846
2 16
07
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
H[m]
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [l/s]
0
100
200
300
400
500
p[kPa]
CH 860 Hz
ISO 9906 Annex A
CH 8-20
CH 8-25
CH 8-30
CH 8-40
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0.0
0.4
0.8
1.2
1.6
P2[kW]
-20-25
-30-40
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
0
1
2
3
NPSH[m]
0
10
20
30
p[kPa]
0
20
40
60
[%]Eta
Eta 1
NPSH
CH 860 HzTechnical data
Dimensions
Weights
Electrical dataTM
00 1
189
3505
/TM
00 1
490
3505
Fig. 11 Dimensional sketches, CH 8
Rp 1/2
Rp 1/2Rp 1 1/2
CH 12 Rp 1 1/2CH 8 Rp 1 1/4
L4
240
ø8.5
L1
L3
L2
160
138
110
188
130
108
B2
B1CH 8 Rp 1 1/4
Rp 1 1/2
Rp 1/2
Rp 1/2
CH 12 Rp 1 1/2L4
240
ø8.5
L1
L3
L2
160
138
110
188
130
108
B1
MG 80 motor MG 90 motor
Voltage[V]
Frequency[Hz] Pump type Motor type L1
[mm]L2
[mm]L3
[mm]L4
[mm]B1
[mm]B2
[mm]
1 x 220 60CH 8-20CH 8-30CH 8-40
MG 80MG 90MG 90
351429429
699999
588888
77107107
177182182
109
3 x 208-230/440-480 (USA) With cUL approval
60
CH 8-20CH 8-25CH 8-30CH 8-40
MG/ML 71MG/ML 80MG/ML 80MG/ML 80
311381381381
69999999
58888888
77107107107
177177177177
109109109109
3 x 575 (Canada)With cUL approval3 x 200/346 (Japan)3 x 200-220/346-400 (Japan)
1 x 115/230 (USA) With cUL approval 60
CH 8-20CH 8-25CH 8-30CH 8-40
ML 80ML 80ML 90ML 90
351381429429
69999999
58888888
77107107107
177177191191
124124132132
* No motor protectionNote: ML motors with cUL approval for USA and Canada.
Pump typeSingle-phase Three-phase
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
CH 8-20CH 8-25CH 8-30CH 8-40
18192626
20212828
0.04220.04220.04220.0422
15.717.018.719.0
18.519.821.521.8
0.04220.04220.04220.0422
Voltage[V]
Frequency[Hz] Pump type Motor type SF I1/1
[A]Ist[A]
P1[W]
P2[W]
Motor P2[HP]
C[µF/V]
1 x 220 60CH 8-20CH 8-30CH 8-40
MG 80MG 90MG 90
5.48.9
10.4
214040
117019202210
83013501570
25/40030/40030/400
3 x 208-230/440-480 (USA)With cUL approval 60
CH 8-20CH 8-25CH 8-30CH 8-40
ML 71ML 80ML 80ML 80
1.701.601.471.47
1.701.601.471.47
4.20/2.105.20/2.606.90/3.506.90/3.50
15.620.432.032.0
0.751
1.51.5
0.751
1.51.5
1 x 115/230 (USA)With cUL approval 60
CH 8-20CH 8-25CH 8-30CH 8-40
ML 80ML 80ML 90ML 90
1.501.501.401.40
1.501.501.401.40
11.5/5.7015.0/7.5021.5/10.721.4/10.6
34.048.083.032.0
0.751
1.51.5
0.751
1.51.5
40/40050/40060/40060/400
3 x 575 (Canada)With cUL approval 60
CH 8-20CH 8-25CH 8-30CH 8-40
ML 71ML 80ML 80ML 80
1.701.601.471.47
1.701.601.471.47
1.682.082.802.80
8.011.215.315.3
0.51
1.51.5
0.51
1.51.5
3 x 200-230/346-400** (Japan) 60
CH 8-20CH 8-25CH 8-30CH 8-40
MG 71MG 80MG 80MG 80
3.5/2.04.5/2.65.9/3.47.6/4.4
15.6/9.020.4/11.832.0/18.432.0/18.8
1084141818302260
859115214001620
** Dual frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.
31
32
CH 1260 HzPerformance curves
CH 12
TM03
846
3 16
07
0 2 4 6 8 10 12 14 16 Q [m³/h]
0
5
10
15
20
25
30
35
40
45
50
55
60
H[m]
0 1 2 3 4 Q [l/s]
0
100
200
300
400
500
600
p[kPa]
CH 1260 Hz
ISO 9906 Annex A
CH 12-40
CH 12-30
CH 12-20
CH 12-10
0 2 4 6 8 10 12 14 16 Q [m³/h]
0
1
2
3
P2[kW]
-10
-20
-30
-40
0 2 4 6 8 10 12 14 16 Q [m³/h]
0
2
4
6
NPSH[m]
0
20
40
60
p[kPa]
0
20
40
60
[%]Eta
Eta 1
NPSH
CH 1260 HzTechnical data
Dimensions
Weights
Electrical dataTM
00 1
189
3505
/TM
00 1
490
3505
Fig. 12 Dimensional sketches, CH 12
Rp 1/2
Rp 1/2Rp 1 1/2
CH 12 Rp 1 1/2CH 8 Rp 1 1/4
L4
240
ø8.5
L1
L3
L2
160
138
110
188
130
108
B2
B1CH 8 Rp 1 1/4
Rp 1 1/2
Rp 1/2
Rp 1/2
CH 12 Rp 1 1/2L4
240
ø8.5
L1
L3
L2
160
138
110
188
130
108
B1
MG 80 motor MG 90 motor
Voltage[V]
Frequency[Hz] Pump type Motor type L1
[mm]L2
[mm]L3
[mm]L4
[mm]B1
[mm]B2
[mm]1 x 220 60 CH 12-20 MG 90 399 69 58 77 182
3 x 208-230/440-480 (USA)With cUL approval 60
CH 12-10CH 12-20CH 12-30
ML 71ML 80ML 90
311351429
696999
585888
7777
107
177177186
109109124
1 x 115/230 (USA)With cUL approval 60 CH 12-10
CH 12-20ML 71ML 90
311399
6969
5858
7777
177191 132
3 x 575 (Canada)With cUL approval 60
CH 12-10CH 12-20CH 12-30
ML 71ML 80ML 90
311351429
696999
585888
7777
107
177177186
109109124
3 x 200/346 (Japan)3 x 200-220/346-380 (Japan)
5060
CH 12-10CH 12-20CH 12-30CH 12-40
MG 71MG 80MG 90MG 90
311351429429
69699999
58588888
7777
107107
177177182182
109109
* No motor protection
Pump typeSingle-phase Three-phase
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
Net weight[kg]
Gross weight[kg]
Shipping volume[m³]
CH 12-10CH 12-20CH 12-30CH 12-40CH 12-50CH 12-60
1527----
1729----
0.04220.0422
----
15.718.826.128.9
--
18.521.628.931.7
--
0.04220.04220.04220.0422
--
Voltage[V]
Frequency[Hz] Pump type Motor type SF I1/1
[A]Ist[A]
P1[W]
P2[W]
Motor P2[HP]
C[µF/V]
1 x 220 60 CH 12-20 MG 90 9.2 40 1980 1430 30/400
3 x 208-230/440-480 (USA)With cUL approval 60
CH 12-10CH 12-20CH 12-30
ML 71ML 80ML 90
1.701.471.50
1.701.471.50
2.90/1.456.90/3.509.10/4.75
15.732.046.0
0.51.52
0.51.52
1 x 115/230 (USA)With cUL approval 60 CH 12-10
CH 12-20ML 71ML 90
1.601.40
1.601.40
9.00/4.5021.5/10.7
24.983.0
0.51.5
0.51.5
40/40060/400
3 x 575 (Canada)With cUL approval 60
CH 12-10CH 12-20CH 12-30
ML 71ML 80ML 90
1.701.471.50
1.701.471.50
1.162.803.80
5.115.328.0
0.51.52
0.51.52
3 x 200-230/346-400** (Japan) 60
CH 12-10CH 12-20CH 12-30CH 12-40
MG 71MG 80MG 90MG 90
2.75/1.65.7/3.38.6/5.011.6/6.7
2.75/1.65.7/3.38.6/5.011.6/6.7
820177026803500
650136021302740
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.
33
34
CH, CHNPumped liquids
Pumped liquidsThin, non-explosive liquids, not containing solid particles or fibres. The liquid must not chemically attack the pump materials.
When pumping liquids with a density and/or viscosity higher than those of water, oversized motors must be used, if required.
Whether a pump is suitable for a particular liquid depends on a number of factors of which the most important are the chloride content, pH value, temperature and content of chemicals and oils.
Please note that aggressive liquids (for instance seawater and some acids) may attack or dissolve the protective oxide film of the stainless steel and thus cause corrosion.
List of pumped liquidsA number of typical liquids are listed below.
Other pump versions may be applicable, but those stated in the list are considered to be the best choices.
The table is intended as a general guide only and cannot replace actual testing of the pumped liquids and pump materials under specific working conditions.
The list should, however, be applied with some caution as factors such as concentration of the pumped liquid, liquid temperature or pressure may affect the chemical resistance of a specific pump version.
Safety precautions must be made when pumping dangerous liquids.
Notes
a May contain additives or impurities which can cause shaft seal problems.
b The density and viscosity may differ from those of water. Consider this when calculating motor and pump performance.
c In order to avoid corrosion, the liquid must be free of oxygen.
d
Flammable or combustible liquid.Safety precautions must be considered to ensure safe handling of flammable liquids. Handling the liquid above the flashpoint and/or boiling point will require the greatest restrictions. A seal-less pump may be required. Contact Grundfos.
e Risk of crystallization/precipitation on the shaft seal.f If oil residues are present, EPDM cannot be used.
Pumped liquids Notes Additional information CH CHNWaterBoiler feed water AQQE/CVBE AQQE/CVBECondensate AQQE/CVBE AQQE/CVBECooling and cutting lubricant a AQQV AQQVGroundwater < 300 ppm chloride AQQE/CVBE AQQE/CVBEDemineralised water AQQE/CVBEDistrict heating water AQQE/CVBE AQQE/CVBEOil-containing water AQQV/CVBV AQQV/CVBVSoftened water AQQE/CVBE AQQE/CVBE
Swimming pool water, chlorinated 40 °C, 150 ppm chloride, < 2 ppm free chlorine AQQE/CVBE AQQE/CVBE
CoolantsEthylene glycol a, b < 50 °C AQQE AQQEGlycerine (glycerol) a, b < 50 °C AQQE AQQEHydrocarbon-based coolant b, d 50 °C AQQV AQQVPotassium acetate (inhibited) a, b, c, e < 20 °C AQQE AQQEPotassium formate (inhibited) a, b, c, e < 20 °C AQQE AQQEPropylene glycol a, b < 50 °C AQQE AQQEFuelsDiesel oil d AQQV/CVBV AQQV/CVBVJet fuel d AQQV/CVBV AQQV/CVBVKerosene d AQQV/CVBV AQQV/CVBVNaphta d AQQV/CVBV AQQV/CVBVPetrol d AQQV/CVBV AQQV/CVBVBiodiesel d AQQV/CVBV AQQV/CVBVMineral oilsCrude oil a, b, d < 20 °C AQQV/CVBV AQQV/CVBVMineral lubricating oil b, d AQQV/CVBV AQQV/CVBVMineral motor oil b, d AQQV/CVBV AQQV/CVBVSynthetic oilsSynthetic lubricating oil b, d AQQV/CVBV AQQV/CVBVSynthetic motor oil b, d AQQV/CVBV AQQV/CVBVSilicone oil b AQQV/CVBV AQQV/CVBV
Pumped liquids CH, CHN
Vegetable oilsCorn oil a, b AQQV/CVBV AQQV/CVBVOlive oil a, b AQQV/CVBV AQQV/CVBVPeanut oil a, b AQQV/CVBV AQQV/CVBVRape-seed oil a, b AQQV/CVBV AQQV/CVBVSoya oil a, b AQQV/CVBV AQQV/CVBVCleaningAlkaline degreasing agent a, f < 80 °C AQQE AQQESoap (salts of fatty acids) a < 80 °C AQQV AQQVOrganic solventsAcetone e 40 °C AQQE/CVBE AQQE/CVBEEthyl alcohol (ethanol) e 40 °C AQQE/CVBE AQQE/CVBEIsopropyl alcohol e 40 °C AQQE/CVBE AQQE/CVBEMethyl alcohol (methanol) e 40 °C AQQE/CVBE AQQE/CVBEOxidantsHydrogen peroxide 20 °C, 5 % AQQE/CVBESalts
Ammonium bicarbonate b20 °C, 15 % AQQE 60 °C, 30 % AQQE
Potassium bicarbonate b20 °C, 20 % AQQE/AQQV60 °C, 30 % AQQE/AQQV
Sodium carbonate b, e20 °C, 20 % AQQE60 °C, 30 % AQQE
Potassium permanganate 20 °C, 1 % AQQE/AQQV
Sodium nitrate b20 °C, 5 % AQQE/AQQV
60 °C, 30 % AQQE/AQQV
Sodium nitrite b20 °C, 20 % AQQE/AQQV60 °C, 30 % AQQE/AQQV
Sodium phosphate (mono) b 60 °C, 5 % AQQE/AQQV
Sodium phosphate (di) b30 °C, 30 % AQQE/AQQV60 °C, 30 % AQQE/AQQV
Sodium phosphate (tri) b, e20 °C, 10 % AQQE/AQQV70 °C, 20 % AQQE/AQQV
Sodium sulphate b, e 60 °C, 30 % AQQE/AQQV
Sodium sulphite b, e20 °C, 1 % AQQE/AQQV
60 °C, 20 % AQQE/AQQVAcidsAcetic acid 20 °C, 5 % AQQECitric acid 20 °C, 1 % AQQENitric acid b 20 °C, 5 % AQQE/AQQVPhosphoric acid a 20 °C, 1 % AQQE/AQQVAlkaliesAmmonium hydroxide 30 °C, 30 % AQQE AQQECalcium hydroxide a 30 °C, 5 % AQQE AQQEPotassium hydroxide b, e 20 °C, 20 % AQQE
60 °C, 20 % AQQESodium hydroxide b, e 20 °C, 20 % AQQE
80 °C, 20 % AQQE
Pumped liquids Notes Additional information CH CHN
35
CH, CHN
36
Variants
Lists of variantsAlthough the Grundfos CH, CHN product range offers a number of pumps for different applications, customers require specific pump solutions to satisfy their needs. Below are the options available for customizing the CH. Contact Grundfos for further information or for requests other than the ones mentioned below.
Motors
Shaft seals
Connections and other variants
Certificates and nameplates
PumpsMotor with thermal protection
Grundfos offers motors with bimetallic thermal switches or temperature-controlled PTC sensors (thermistors) in the motor windings.
Oversize motor
In installations where one of the conditions mentioned below is present, the motor size must be evaluated to make sure there will be no risk of overload. • Ambient temperatures above 55 °C.• Liquid temperatures below 0 °C.• Installation at an altitude of more than
1000 metres above sea level • Use of glycol or other high-viscous liquids.Alternative motors are available on request.
Dual-voltage motors 50/60 hz
In some cases the standard product can run at dual voltage and frequency. If the standard product cannot be used for dual voltage, a bigger motor can very often be used instead.
Use of external frequency converter
For most three-phase CH, CHN pumps a frequency converter can be used. Single-phase motors are not suitable for frequency converter operation. In many cases where an external frequency converter is used it is necessary to protect the motor against voltage peaks higher than 650 V (peak value). In these cases it is often less expensive to ask for phase insulation in the pump than use a filter such as an LC filter. Grundfos offers pumps with phase insulation to protect the pump against voltage peaks up to 1000 V (peak values). This is a customized version, and the supplier of the frequency converter must be consulted.
Harting plug Harting plugs are available for easier replacement of pumps.
Terminal box position Other terminal box positions are possible.
CVBV, CVBE, AQQE, AQQV are standard for CH, CHN pumps.Shaft seals with FFKM or FXM O-ring material are recommended for applications where the pumped liquid may damage the standard O-ring material.
Pipe connections NPT and Rp threads are available.
Certificates
Certificate of compliance with the orderTest certificateInspection certificateStandard test report
Extra nameplate
UR-marked motorIf the UL-listed product according to UL778 is not available, a pump with UR-marked motor according to UL1004 can be offered as an alternative.
Low-temperature pump
Exposed to temperatures below –20 °C, coolant pumps may require neck rings with a different diameter or without a neck ring in order to prevent impeller drag. If neck rings are removed, a reduction of the head must be expected. In some extreme cases, –25 °C cold liquids can be pumped by a CH pump. Contact Grundfos.
CH, CHNFurther product documentation
WebCAPSWebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages.
In WebCAPS, all information is divided into 6 sections:
• Catalogue• Literature• Service• Sizing• Replacement• CAD drawings.
Catalogue
This section is based on fields of application and pump types, and contains • technical data• curves (QH, Eta, P1, P2, etc) which can be adapted to the den-
sity and viscosity of the pumped liquid and show the number of pumps in operation
• product photos• dimensional drawings• wiring diagrams• quotation texts, etc.
Literature
In this section you can access all the latest documents of a given pump, such as• data booklets• installation and operating instructions• service documentation, such as Service kit catalogue and
Service kit instructions• quick guides• product brochures.
Service
This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and dis-continued Grundfos pumps.Furthermore, this section contains service videos showing you how to replace service parts.
37
38
Further product documentation
CH, CHN
WinCAPS
Fig. 13 WinCAPS CD-ROM
WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed informa-tion on more than 185,000 Grundfos products in more than 20 languages.
The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available.
WinCAPS is available on CD-ROM and updated once a year.
Sizing
This section is based on different fields of application and installa-tion examples, and gives easy step-by-step instructions in how to• select the most suitable and efficient pump for your installation• carry out advanced calculations based on energy consumption,
payback periods, load profiles, life cycle costs, etc.• analyse your selected pump via the built-in life cycle cost tool• determine the flow velocity in wastewater applications, etc.
Replacement
In this section you find a guide to selecting and comparing replace-ment data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos.
Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.
CAD drawings
In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps.
These formats are available in WebCAPS:
2-dimensional drawings:• .dxf, wireframe drawings• .dwg, wireframe drawings.
3-dimensional drawings:• .dwg, wireframe drawings (without surfaces)• .stp, solid drawings (with surfaces)• .eprt, E-drawings.
0 1
39
www.grundfos.com
V7173560 0407 GBRepl. V7173560 0107 Subject to alterations.
Being responsible is our foundationThinking ahead makes it possible
Innovation is the essence
GRUNDFOS A/S . DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00
top related