® Ultrasonic Flowmeter System

EuropeStrain Measurement DevicesBury Road, Chedburgh, Bury St Edmunds IP29 4UQsales@smdsensors.co.uk | +44 (0)1284 852 000

USAStrain Measurement Devices

55 Barnes Park North, Wallingford, CT 06492sales@smdsensors.com | (203) 294-5800

www.smdsensors.com

Applications:

· Medical Devices· Laboratory Tests· Bioprocessing· Industrial Flow Measurements

This electronic module is used with either In-Line or Clamp-On �ow sensors, measuring �ow in tubes, pipes, and blood vessels. The system calculates the proportional �ow rates via the transit time di�erence between upstream and downstream ultrasonic signals. Temperature and pressure measurements are optional, and the system can provide information on �ow rate, accumulated �ow volume, sound speed in liquid/gas, and signal strength. The FlowDAQ® module is equipped with a 4.3” touch screen for display, controlling information on �ow and system settings, and allowing zero calibration. The system can be connected to a computer through the UART serial port using a USB-Serial converted cable, and be con�gured using the system software. Instantaneous �ow rate, �ow history, and ultrasonic wave form can all be displayed on the computer screen

graphically. Flow information can also be exported and saved as data �les for further analysis.

ISO9001Registered

ISO13485Registered

Product Speci�cationsMaterials:

Display & Control:

Input Voltage & Current:

Flowmeter Analog & UART Output:

Connector Speci�cations:

PC /ABS (CHIMEI PC-345)

Touch Screen

Voltage: 6 - 30 VDCCurrent: 230 mA at 18 VDC

UARTBaud Rate: 115200Data Bits: 8Stop Bits: 1Parity: None

AnalogOutput 1: +/-5V Flow Rate

Output 2: 0 - 2V Ultrasonic signal strength (must be between 0.4-2V to guarantee accurate measurements)

Connector 1: TransducerConnecter 2: BNC, +/-5V Analog Output, Flow RateConnecter 3: BNC, 0 - 2V Analog Output, Signal StrengthConnecter 4: UART Digital OutputConnecter 5: 6 to 30 VDC, Power Unit

ISO9001Registered

ISO13485Registered

www.smdsensors.com

2.78”[70.73 mm]

4.38”[111.25 mm]

8.85” [224.86 mm]

8.07” [204.97 mm]

4X Ø 0.18” [4.57 mm]

Connector 1: Transducer

1.90”[48.28 mm]

0.25”[6.35 mm] Connector 2: Flow Rate

Connector 3: Signal StrengthConnector 4: Digital Output

Connector 5: Power Input