for Datacom NetworksFIBER OPTIC CABLES
Optical Cable Specifications The Fiber specification meetsthe requirements of ISO 11801,and TIA/EIA B. The optical fiberspecifications are guaranteedinstalled minimum performance(subject to correct installationand environment). If a higherperformance fiber is required,please contact our local salesteams.
Maximum Attentuation (dB/km)
Loose Tube Tight Buffered
Multimode 850 nm 1300 nm 850 nm 1300 nm
50/125 3.5 1.0 3.5 1.5
62.5/125 3.5 1.0 3.5 1.5
Singlemode 1310 nm 1550 nm 1310 nm 1550 nm
9/125 0.45 0.35 0.5 0.4
Quality StandardsAll Tyco Electronics cables are designed and manufactured in our dedicated modern facilities and all activities are controlled within ISO 9001 systems.All our products have undergone extensive type approval testing to IEC 60793 and IEC 60794, using our up to date testing facilities. Copies of test reports are available on request.
Specifications
It is Tyco Electronics policy to offer a wide range of options tosuit the individual needs of each application. The table belowshows the main options, but as new fibers are continuallydeveloped, please ask if you require a fiber not shown.
Fibers shown in the cable specification tables below are the standard fibers which appear throughout this catalogue.
Optical Fiber Specifications
Multimode Fibers
Multimode Overfill Bandwidth Max. Link Length** Max. Link Length** Fiber Attenuation Fiber GeometricalFibers for 1 GBit/s for 10 GBit/s properties
(MHz x km) (m) (m) (dB/km) (µm)
EN 50173/ISO 11801 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm 850 nm 1300 nm Core Cladding Coating(1000Base-SX) (1000Base-LX) (10GBase-SR) (10GBase-LX4)
(10GBase-SW)
50/125 µm
OM2 ≥ 500 ≥ 500 550 550* 82 300* ≤ 2.4 ≤ 0.6 50 ± 3 125 ± 2 245 ±10
OM2 750 laser optimised ≥ 600 ≥ 1200 750 2000 100 1000 ≤ 2.4 ≤ 0.6 50 ± 3 125 ± 2 245 ±10
OM3 ≥ 1500 ≥ 500 1000 600 300 300 ≤ 2.7 ≤ 0.7 50 ± 3 125 ± 2 245 ±10
OM4 laser optimised ≥ 3500*** ≥ 500 1040 600 550 300 ≤ 2.7 ≤ 0.7 50 ± 3 125 ± 2 245 ± 10
* Mode Conditioning Patchcords required** Longer link lengths may be achievable, depending upon system parameters. Please discuss your needs with us.
*** EMB OM4: 4700
62.5/125 µm
OM1 ≥ 200 ≥ 600 275 550* 33 360* ≤ 2.9 ≤ 0.7 62.5 ± 3 125 ± 2 245 ±10
OM1 500 laser optimised ≥ 250 ≥ 600 400 1000 65 450 ≤ 2.9 ≤ 0.7 62.5 ± 3 125 ± 2 245 ±10
* Mode Conditioning Patchcords required** Longer link lengths may be achievable, depending upon system parameters. Please discuss your needs with us.
Singlemode Fibers
Singlemode Chromatic Cut-off Wave- Point Fiber Attenuation Fiber GeometricalFibers Dispersion length (cabled) Discontinuity properties
IEC 60793/(nm) (dB) (dB/km) (µm)
EN 50173/ISO 11801 1310 nm 1550 nm 1310 nm 1380–1386 nm 1550 nm Mode-field Ø Cladding Coating
9/125 µm
OS2 (ITU-T G.652D) ≤ 3.5 ≤ 18.0 ≥ 1260 ≤ 0.1 ≤ 0.34 ≤ 0.31 ≤ 0.22 9.2 ± 0.4 125 ± 1 245 ±5
Interconnect: Simplex and Zip Twin
Features:
l Range of fibers availablel Direct Terminationl Compact Rugged Constructionl LSZH sheathl Tight or Semi-tight (Easistrip) bufferl Mini Zip Twin: nylon tight bufferl Sheaths and buffers in a wide range
of colorsl Fibers color coded according to
TIA/EIA-598, for easy identificationl Temperature range:
– transport/storage: –10°C to +60°C– installation: – 5°C to +50°C– operation: –10°C to +60°C
l Crush resistance: 1000 Nl Diameter over buffered fiber:
900 +/– 50 µm
Applications:
Ideal for patch leads, pigtails, test leads, etc.
Simplex tight jacketed cables are designed to be used in patch leads and pigtails orfor connections within buildings. Zip Twin cables, often referred to as Duplex cables,are constructed with two Simplex units joined together by a central web. These tightjacketed cables utilise 900 micron buffered fiber and are constructed into 2.8 mmcables. In addition, Mini Zip Twin cable is also available, using 600 micron buffers.
Optional designs (on request):
– 1.6, 2.0, 2.4, 2.5, 3.0 mm diameters– Sheaths and buffers in a wide range
of colors– Buffer types available:
Tight (nominal strip length 25 mm)Semi-tight (nominal strip length 300 mm)Loose (nominal strip length 1000 mm)
– UL approved range of interconnect cables– Riser UL1666 and LSZH dual rated cables
available
Standards:
Cable properties IEC 60794Flammability IEC 60332 parts 1 & 3Smoke Emission IEC 61034 parts 1 & 2Acid Gas Emission IEC 60754 parts 1 & 2Toxicity NES 713
Mechanical Characteristics
Cable Nominal Nominal Installation Min. Installation Static Combustion Part NumbersType Cable OD Weight Tension Bend Radius Bend Radius Energy
(mm) (kg/km) (N) (mm) (mm) (MJ/m) 50/125 µm 62.5/125 µm 9/125 µm
Simplex (tight) 2.8 7 150 140 90 0.15 Y-1592016-1 Y-1592017-3 0-1594766-6
Simplex (semi-tight) 2.8 7 150 140 90 0.15 Y-1592006-1 Y-1592007-3 0-1592008-6
Zip Twin (tight) 2.8 x 5.8 14 300 140 90 0.30 Y-1592043-1 Y-1592044-3 0-1594681-6
Zip Twin (semi-tight) 2.8 x 5.8 14 300 140 90 0.30 Y-1592035-1 Y-1592036-3 0-1592037-6
Mini Zip Twin (tight) 1.8 x 3.8 6 200 90 60 0.20 Y-1592062-1 Y-1592063-3 0-1592064-6
All specifications subject to change. Consult Tyco Electronics for latest specifications. 1
I-V(ZN)H
I-V(ZN)H
Y- Bandw. Cat.
2- 500/500 OM2
7- 600/1200 OM2 750
8- 1500/500 OM3
9- 3500/500 OM4(OFL)
Y- Bandw. Cat.
0- 200/600 OM1
7- 350/600 OM1 500
Standard sheath colors indicate fiber type: orange = 50/125: Part Number suffix -1grey = 62.5/125: Part Number suffix -3yellow = 9/125: Part Number suffix -6
LSZH sheath
Aramid strengthmembers
Buffered optical fiber
LSZH sheath
Aramid strengthmembers
Buffered optical fiber
Fiber and buffer colors (TIA/EIA 568)
1–2 blue, orange
Optional designs (on request):
– UL approved PVC cables– Aramid yarns – Sheath and buffers in a wide range
of colors– Buffer types available:
Tight (nominal strip length 25 mm)Semi-tight (nominal strip length 300 mm)Loose (nominal strip length 1000 mm)
– Available with 36, 48 or 72 fibres – 3.4 mm diameter for fiber-to-the-desk
installations of 2 or 4 fiber cables– Full breakout cables also available
Standards:
Cable properties IEC 60794Flammability IEC 60332 parts 1 & 3Smoke Emission IEC 61034 parts 1 & 2Acid Gas Emission IEC 60754 parts 1 & 2Toxicity NES 713
Features:
l Direct Terminationl Resistance against rodentsl Compact Rugged Constructionl ULSZH sheath flame retardant and
resistant to UV and water ingressl Tight or semi-tight (Easistrip) bufferl Fibers color coded according to
TIA/EIA-598, for easy identificationl Temperature range:
– transport/storage: –20 °C to +60 °C– installation: –5 °C to +50 °C– operation: –20 °C to +60 °C(except 24f which is –10 °C to +60 °C)
l Crush Resistance: 2000 N
Applications:
Ideal for offices and for both internal andexternal areas where flexibility and com-pact diameter are required. Also for hori-zontal and backbone cabling and structur–ed wiring systems. Suitable for direct ter-mination to MT-RJ, SC and ST connectors.
Tyco Electronics’ range of Office Distribution Cables (ODC’s) is designed to offerflexibility, strength and compact construction for internal and interbuilding use.Available up to 24 fibers in unstranded form, or from 24 to 48 fibers in stranded form,providing higher strength. The cables are of non-metallic construction reinforced byE-glass yarns, which provide rodent resistance and higher tensile strength, andoversheathed with a ULSZH jacket meeting IEC fire performance requirements.
Office Distribution
Mechanical Characteristics – Universal Office Distribution
Cable Nominal Nominal Installation Min. Installation Static Combustion Part NumbersType Cable OD Weight Tension Bend Radius Bend Radius Energy
(mm) (kg/km) (N) (mm) (mm) (MJ/m) 50/125 µm 62.5/125 µm 9/125 µm
2f (tight) 5.2 32 1000 130 80 0.40 Y-1592137-1 Y-1592138-3 0-1594769-6
2f (semi-tight) 5.2 32 1000 130 80 0.40 Y-1592110-1 Y-1592111-3 0-1592067-6
4f (tight) 5.5 33 1000 130 80 0.40 Y-1592139-1 Y-1592140-3 0-1594678-6
4f (semi-tight) 5.5 33 1000 130 80 0.40 Y-1592113-1 Y-1592114-3 0-1592115-6
6f (tight) 6.4 46 1500 150 90 0.55 Y-1592141-1 Y-1592142-3 0-1594770-6
6f (semi-tight) 6.4 46 1500 150 90 0.55 Y-1592116-1 Y-1592117-3 0-1592118-6
8f (tight) 6.4 49 1500 150 90 0.55 Y-1592143-1 Y-1592144-3 0-1594679-6
8f (semi-tight) 6.4 49 1500 150 90 0.55 Y-1592119-1 Y-1592120-3 0-1592121-6
12f (tight) 8.0 69 1500 200 120 0.80 Y-1592145-1 Y-1592146-3 0-1594680-6
12f (semi-tight) 8.0 69 1500 200 120 0.80 Y-1592122-1 Y-1592123-3 0-1592124-6
16f (tight) 9.0 90 2000 230 140 1.10 Y-1592147-1 Y-1592148-3 0-1594771-6
16f (semi-tight) 9.0 90 2000 230 140 1.10 Y-1592125-1 Y-1592126-3 0-1592127-6
24f (tight) 9.5 92 2000 240 150 1.30 Y-1594455-1 Y-1594456-3 0-1594559-6
24f (semi-tight) 9.5 92 2000 240 150 1.30 Y-1594767-1 Y-1594768-3 0-1594454-6
2 All specifications subject to change. Consult Tyco Electronics for latest specifications.
I/A-V(ZN)H
Standard sheath colors indicate fiber type: orange = 50/125: Part Number suffix -1grey = 62.5/125: Part Number suffix -3yellow = 9/125: Part Number suffix -6
ULSZH sheath
E-glass strength members
0.9 mm buffered optical fiber
Y- Bandw. Cat.
2- 500/500 OM2
7- 600/1200 OM2 750
8- 1500/500 OM3
9- 3500/500 OM4(OFL)
Y- Bandw. Cat.
0- 200/600 OM1
7- 350/600 OM1 500
Fiber and buffer colors (TIA/EIA 568)
1–4 blue, orange, green, brown5–8 grey, white, red, black9–12 yellow, violet, pink, turquoise
13–24 as 1-12, then same colors banded (black bands, except black buffer which has white band)
Universal Loose Tube
All specifications subject to change. Consult Tyco Electronics for latest specifications. 3
Optional designs (on request):
– Aramid yarns– Increased diameter with higher
installation tension– A composite or hybrid cable is
available on request which is a construction of singlemode and multimode fibers in the same design
– Sheaths in a wide range of colors– Dry waterblocked tubes
Standards:
Cable properties IEC 60794Flammability IEC 60332 parts 1 & 3Smoke Emission IEC 61034 parts 1 & 2Acid Gas Emission IEC 60754 parts 1 & 2Toxicity NES 713
Features:
l Compact construction for optimumspace utilisation
l ULSZH sheath flame retardant andresistant to UV and water ingress
l Suitable for direct burial in ductsl Rodent resistantl Totally non-metallic – light and easy
to carry and installl Longitudinal and lateral waterblockingl Fibers color coded according to
TIA/EIA-568, for easy identificationl Temperature Range:
– transport/storage: –20 °C to +60 °C– installation: –5 °C to +50 °C– operation: –20 °C to +60 °C
l Crush Resistance: 2000 N
Applications:
Ideal for use either inside or outside buildings. Intrabuilding links in a campusenvironment are possible. Also suitable for outdoor areas with intermittent flooding or moisture exposure.
Universal Loose Tube non-metallic cables contain up to 24 individually identifiablefibers within a single gel-filled polymeric loose tube, which is then strengthened withE-Glass strength members for rodent resistance and oversheathed with UniversalLSZH jacket for internal/external applications.
Mechanical Characteristics – Universal Loose Tube
Cable Nominal Nominal Installation Min. Installation Static Combustion Part NumbersType Cable OD Weight Tension Bend Radius Bend Radius Energy
(mm) (kg/km) (N) (mm) (mm) (MJ/m) 50/125 µm 62.5/125 µm 9/125 µm
2f 6.4 48 1250 140 130 0.80 Y-1593090-1 Y-1593091-3 0-1593092-6
4f 6.4 48 1250 140 130 0.80 Y-1593093-1 Y-1593094-3 0-1593095-6
6f 6.4 48 1250 140 130 0.80 Y-1593096-1 Y-1593097-3 0-1593098-6
8f 6.4 48 1250 140 130 0.80 Y-1593099-1 Y-1593100-3 0-1593101-6
12f 6.4 48 1250 140 130 0.80 Y-1593105-1 Y-1593106-3 0-1593107-6
16f 6.4 48 1250 140 130 0.80 Y-1593108-1 Y-1593109-3 0-1593110-6
24f 8.0 62 1250 150 140 1.20 Y-1593042-1 Y-1593043-3 0-1593044-6
I/A-DQ(ZN)BH
Standard sheath colors indicate fiber type: orange = 50/125: Part Number suffix -1grey = 62.5/125: Part Number suffix -3yellow = 9/125: Part Number suffix -6
ULSZH sheath
E-glass strengthmembers
Fibers
Loose tube
Y- Bandw. Cat.
2- 500/500 OM2
7- 600/1200 OM2 750
8- 1500/500 OM3
9- 3500/500 OM4(OFL)
Y- Bandw. Cat.
0- 200/600 OM1
7- 350/600 OM1 500
Fiber and buffer colors (TIA/EIA 568)
1–4 blue, orange, green, brown5–8 grey, white, red, black9–12 yellow, violet, pink, turquoise
13–16 (16 fiber cables) magenta, olive, dark green, natural13–24 (24 fiber cables) as 1-12, then same colors banded,
except black replaced by natural banded
Optional designs (on request):
– Alternative diameters and installationtensions
– A composite or hybrid cable is avail-able on request which is a construc-tion of singlemode and multimodefibers in the same design
– Chemical resistant nylon over-sheathavailable
– Sheaths in a wide range of colors– Dry waterblocked tubes– HDPE sheath– ULSZH sheath
Standards:
Cable properties IEC 60794
Features:
l Suitable for most direct burial installations
l Rodent resistantl Improved abrasion resistancel Totally non-metallic – light and easy
to installl Standard black LLDPE sheath for
protection against UV radiationl Longitudinal and lateral waterblockingl Fibers color coded according to
TIA/EIA-568, for easy identificationl Temperature range:
– transport/storage: –20°C to +70°C– installation: –5°C to +50°C– operation: –20°C to +70°C
l Crush Resistance: 2000 N
Applications:
Ideal for installation in ducts and for otherexternal requirements, e.g. structuredwiring systems in networks for telecoms,cable TV and broadcasting.
This range of Loose Tube cables is designed for external applications where improvedmechanical properties are required. The cable is a gel-filled loose tube constructioncontaining 2 to 24 individually identifiable multimode or singlemode optical fibers. Water swellable non-metallic E-glass peripheral strength members for rodent resis-tance are stranded around the loose tube and oversheathed with an LLDPE outerjacket as standard.
External Loose Tube
Mechanical Characteristics – External Loose Tube
Cable Nominal Nominal Installation Min. Installation Static Combustion Part NumbersType Cable OD Weight Tension Bend Radius Bend Radius Energy
(mm) (kg/km) (N) (mm) (mm) (MJ/m) 50/125 µm 62.5/125 µm 9/125 µm
2f 8.4 64 2200 170 150 1.90 Y-1593132-5 Y-1593133-5 0-1593134-5
4f 8.4 64 2200 170 150 1.90 Y-1593135-5 Y-1593136-5 0-1593137-5
6f 8.4 64 2200 170 150 1.90 Y-1593138-5 Y-1593139-5 0-1593140-5
8f 8.4 64 2200 170 150 1.90 Y-1593141-5 Y-1593142-5 0-1593143-5
12f 8.4 64 2200 170 150 1.90 Y-1593147-5 Y-1593148-5 0-1593149-5
16f 8.4 64 2200 170 150 1.90 Y-1593150-5 Y-1593151-5 0-1593152-5
24f 9.2 74 2200 185 160 2.50 Y-1593195-5 Y-1593196-5 0-1593197-5
4 All specifications subject to change. Consult Tyco Electronics for latest specifications.
A-DQ(ZN)B2Y
Standard sheath color black: Part Number suffix -5
LLDPE sheath
E-glass strength members
Optical fiber
Loose tube
Y- Bandw. Cat.
2- 500/500 OM2
7- 600/1200 OM2 750
8- 1500/500 OM3
9- 3500/500 OM4(OFL)
Y- Bandw. Cat.
0- 200/600 OM1
7- 350/600 OM1 500Fiber and buffer colors (TIA/EIA 568)
1–4 blue, orange, green, brown5–8 grey, white, red, black9–12 yellow, violet, pink, turquoise
13–16 (16 fiber cables) magenta, olive, dark green, natural13–24 (24 fiber cables) as 1–12, then same colors banded,
except black replaced by natural banded
Multitube
All specifications subject to change. Consult Tyco Electronics for latest specifications. 5
Optional designs (on request):
– Up to 288 fibers available– Composite cables containing two or
more fiber types in different tubes– Chemical resistant nylon over-sheath
available on cables up to 48 fibers.– Interstitial water blocking gel– Dry waterblocked tubes– Aramid strengthening in place of
E-Glass– LSZH or ULSZH sheaths for indoor or
universal applications.– HDPE sheath– Sheaths and tubes in a wide range
of colors– Smaller diameter compact cables
also available
Standards:
Cable properties IEC 60794
Features:
l Suitable for most direct burial installations
l Rodent resistantl Improved abrasion resistancel Totally non-metallic – light and easy
to installl Standard black LLDPE sheath for
protection against UV radiationl Longitudinal and lateral water-blockingl Interstitial dry waterblocking as
standardl Fibers color coded according to
TIA/EIA-568, for easy identificationl Temperature Range
– transport/storage: –30°C to +70°C– installation: –5°C to +50°C– operation: –30°C to +70°C
l Crush Resistance: 2000 N
Applications:
Ideal for installation in ducts and forother external requirements, e.g. struc-tured wiring systems in networks for telecoms, cable TV and broadcasting.
Multitube Loose Tube cables are available in constructions from 4 tubes upwards. Each tube can contain up to 12 fibers. The individually identifiable optical fibers are contained within the gel-filled polymeric tubes stranded around a nonmetallic central strength member. E-Glass peripheral strength members provide extrastrengthening and resistance to rodents. LLDPE outer jacket material as standard.
A-DQ(ZN)B2Y
Standard sheath color black: Part Number suffix -5
Mechanical Characteristics – Multitube
Cable No. of Nominal Nominal Installation Min. Installation Static Combustion Part NumbersType Tubes Cable OD Weight Tension Bend Radius Bend Radius Energy
(mm) (kg/km) (N) (mm) (mm) (MJ/m) 50/125 µm 62.5/125 µm 9/125 µm
24f 4 11.5 100 4000 230 170 3.60 Y-1593462-5 Y-1593463-5 0-1593464-5
32f 4 11.5 100 4000 230 170 3.60 Y-1594776-5 Y-1594777-5 0-1594775-5
36f 4 11.5 100 4000 230 170 3.60 Y-1593468-5 Y-1593469-5 0-1593470-5
48f 4 11.5 100 4000 230 170 3.60 Y-1593474-5 Y-1593475-5 0-1593476-5
60f 6 12.7 114 4000 250 180 4.60 Y-1593591-5 Y-1593592-5 0-1593593-5
72f 6 12.7 114 4000 250 180 4.60 Y-1593594-5 Y-1593595-5 0-1593596-5
96f 8 15.0 221 4000 300 190 6.85 Y-1594772-5 Y-1594430-5 0-1594503-5
144f 12 17.2 274 4000 345 205 9.60 Y-1594773-5 Y-1594478-5 0-1594774-5
Y- Bandw. Cat.
2- 500/500 OM2
7- 600/1200 OM2 750
8- 1500/500 OM3
9- 3500/500 OM4(OFL)
LLDPE sheath
E-glass strength members
Optical fiber
Central strengthmember
Ripcord
Water blocking gel
Loose tube
Fiber and buffer colors (TIA/EIA 568)
1–4 blue, orange, green, brown5–8 grey, white, red, black9–12 yellow, violet, pink, turquoise
Y- Bandw. Cat.
0- 200/600 OM1
7- 350/600 OM1 500
Features:
l The corrugated steel tape provides rodent protection along with excellent crush and impact resistance
l This design is lightweight and flexible for ease of installation
l Outer jacket is bonded to CST armorl Suitable for direct buriall Improved abrasion resistancel Standard black LLDPE sheath for
protection against UV radiationl Longitudinal and lateral waterblockingl Interstitial dry waterblocking as
standard in multitubesl Fibers color coded according to
TIA/EIA-568, for easy identificationl Temperature Range:
Unitube:– transport/storage: –20°C to +70°C– installation: –5°C to +50°C– operation: –20°C to +70°CMultitube:– transport/storage: –30°C to +70°C– installation: –5°C to +50°C– operation: –30°C to +70°C
l Crush Resistance: 3000 N
Applications:
Ideal for direct burial in the ground and other external applications where higher protection is required. It is also applicable for installation in ducts and for other externalrequirements, e.g. structured wiring systems in networks for telecoms, cable TV andbroadcasting. Its non-metallic core permits installation in high voltage environments.Suitable in areas subject to regular or permanent flooding.
CST Armored cables consist of one tube containing up to 24 optical fibers or multiple tubes each containing up to 12 optical fibers. Water blocking E-glassstrength members surround the tube(s) and a plastic coated corrugated steel tape is longitudinally applied. A black LDPE outer jacket is standard.
CST Armored
6 All specifications subject to change. Consult Tyco Electronics for latest specifications.
A-DQ(ZN)(SR)2Y
Standard sheath color black: Part Number suffix -5
Mechanical Characteristics – CST Armored Cable
Cable No. of Nominal Nominal Installation Min. Installation Static Combustion Part NumbersType Tubes Cable OD Weight Tension Bend Radius Bend Radius Energy
(mm) (kg/km) (N) (mm) (mm) (MJ/m) 50/125 µm 62.5/125 µm 9/125 µm
2f 1 10 97 1250 160 160 3.30 Y-1594294-5 Y-1594300-5 0-1594288-5
4f 1 10 97 1250 160 160 3.30 Y-1594295-5 Y-1594198-5 0-1594289-5
6f 1 10 97 1250 160 160 3.30 Y-1594296-5 Y-1594258-5 0-1594290-5
8f 1 10 97 1250 160 160 3.30 Y-1594297-5 Y-1594301-5 0-1594291-5
12f 1 10 97 1250 160 160 3.30 Y-1594298-5 Y-1594302-5 0-1594292-5
16f 1 10 97 1250 160 160 3.30 Y-1594299-5 Y-1594303-5 0-1594293-5
24f 1 10.5 107 1250 160 160 4.0 Y-1594035-5 Y-1594036-5 0-1594037-5
36f 6 15 200 4000 290 190 7.20 Y-1594306-5 Y-1594308-5 0-1594304-5
48f 6 15 200 4000 290 190 7.20 Y-1594307-5 Y-1594309-5 0-1594305-5
60f 6 15 200 4000 290 190 7.20 Y-1594086-5 Y-1594087-5 0-1594088-5
72f 6 15 200 4000 290 190 7.20 Y-1594089-5 Y-1594090-5 0-1594091-5
LLDPE sheath
Corrugated steel tape armoring
Water blocking gel
Optical fibers
E-glass strengthmembers
Loose tube
Y- Bandw. Cat.
2- 500/500 OM2
7- 600/1200 OM2 750
8- 1500/500 OM3
9- 3500/500 OM4(OFL)
Optional designs (on request):
– Up to 288 fibers available– Universal low smoke zero halogen
sheath for internal/external use– HDPE sheath– Second sheath in either polyethylene
or ULSZH– Chemical resistant nylon over-sheath– Interstitial waterblocking gel
Other types of armor available are:
– Galvanised steel wire armor to providean alternative high strength and crushresistant armor
– Braiding to provide a flexible, crushresistant armor
Standards:
Cable properties IEC 60794
Fiber and buffer colors (TIA/EIA 568)
1–4 blue, orange, green, brown5–8 grey, white, red, black9–12 yellow, violet, pink, turquoise
13–16 (16 fiber unitube) magenta, olive, dark green, natural13–24 (24 fiber unitube) as 1–12, then same colors banded,
except black replaced by natural banded
Y- Bandw. Cat.
0- 200/600 OM1
7- 350/600 OM1 500
GRP Armored
All specifications subject to change. Consult Tyco Electronics for latest specifications. 7
Mechanical Characteristics – GRP Armored Cable
Cable No. of Nominal Nominal Installation Min. Installation Static Combustion Part NumbersType Tubes Cable OD Weight Tension Bend Radius Bend Radius Energy
(mm) (kg/km) (N) (mm) (mm) (MJ/m) 50/125 µm 62.5/125 µm 9/125 µm
2f 1 9.0 72 2000 230 175 2.30 Y-1593807-5 Y-1593808-5 Y-1593809-X
4f 1 9.0 72 2000 230 175 2.30 Y-1593738-5 Y-1593811-5 Y-1593812-X
6f 1 9.0 72 2000 230 175 2.30 Y-1593813-5 Y-1593814-5 Y-1593815-X
8f 1 9.0 72 2000 230 175 2.30 Y-1593816-5 Y-1593817-5 Y-1593818-X
12f 1 9.0 72 2000 230 175 2.30 Y-1593822-5 Y-1593823-5 Y-1593824-X
16f 1 9.0 72 2000 230 175 2.30 Y-1593825-5 Y-1593826-5 Y-1593827-X
24f 1 11.0 103 3000 280 210 4.00 Y-1594427-5 Y-1594419-5 Y-1594423-X
36f 4 15.0 183 6000 465 350 5.65 Y-1594428-5 Y-1594420-5 Y-1594424-X
48f 4 15.0 183 6000 465 350 5.65 Y-1593951-5 Y-1593955-5 Y-1593956-X
60f 6 16.7 206 6000 520 390 8.00 Y-1594429-5 Y-1594421-5 Y-1594425-X
72f 6 16.7 206 6000 520 390 8.00 Y-1594402-5 Y-1594422-5 Y-1594426-X
Optional designs (on request):
– Higher number of fibers– Universal low smoke zero halogen
sheath for internal/external use– High Density Polyethylene (HDPE)
sheath also available– Chemical resistant nylon over-sheath– Second sheath in either polyethylene
or ULSZH
Standards:
Cable properties IEC 60794
Features:
l The GRP rods provide rodent protec-tion along with excellent crush and impact resistance
l Maximum protection through use of GRP for all rods, without any fillers
l Installation tension up to 6000 Nl Suitable for direct buriall Improved abrasion resistancel Totally non-metallicl Standard black LLDPE sheath for
protection against UV radiationl Longitudinal and lateral waterblocking
within the cable corel Interstitial dry waterblocking as
standard in multitubesl Fibers color coded according to
TIA/EIA-568, for easy identificationl Temperature Range:
Unitube:– transport/storage: –20°C to +70°C– installation: –5°C to +50°C– operation: –20°C to +70°CMultitube:– transport/storage: –30°C to +70°C– installation: –5°C to +50°C– operation: –30°C to +70°C
l Crush Resistance: 2000 N up to 24 fibers, 4000 N for cables with more than 24 fibers
GRP Armored cables consist of one tube containing up to 24 optical fibers or multiple tubes each containing up to 12 optical fibers. GRP crush resistant rods are helically stranded around the loose tube, providing significant extra strength and resistance to rodents. A PE jacket is then applied.
A-DQ(ZN)B2Y
Standard sheath color black: Part Number suffix -5
Applications:
Wherever extra high strength is required. Ideal for direct burial in the ground and otherexternal applications where higher protection is required. Also applicable for installationin ducts and for other external requirements, e.g. structured wiring systems in networksfor telecoms, cable TV and broadcasting. Its non-metallic core permits installation inhigh voltage environments. Suitable for short span aerial applications.
LLDPE sheath
Non-metallic armoringWater blocking Gel
Central strength memberWrapping tapeLoose tube
Optical fibers
Y- Bandw. Cat.
2- 500/500 OM2
7- 600/1200 OM2 750
8- 1500/500 OM3
9- 3500/500 OM4(OFL)
Fiber and buffer colors (TIA/EIA 568)
1–4 blue, orange, green, brown5–8 grey, white, red, black9–12 yellow, violet, pink, turquoise
13–16 (16 fiber unitube) magenta, olive, dark green, natural13–24 (24 fiber unitube) as 1–12, then same colors banded,
except black replaced by natural banded
Y- Bandw. Cat.
0- 200/600 OM1
7- 350/600 OM1 500
Fire Survival Cable
8 All specifications subject to change. Consult Tyco Electronics for latest specifications.
Standards:
IEC 60794IEC 60331-25 (90 mins)IEC 60332 pt 1 and Pt 3CIEC 61034IEC 60754ISO 11801Cable properties IEC 60794
Features:
l Circuit integrity for 90 minutes at750 °C
l Suitable for direct buriall Excellent crush resistance: 3000Nl Compact construction for optimum
space utilisationl Rodent resistantl Longitudinal and lateral water blockingl Fibers color coded according to
TIA/EIA-598, for easy identificationl Temperature Range:
Transport/storage: –20 °C to +70 °CInstallation: –5 °C to +50 °COperation: –20 °C to +70 °C
Applications:
Designed for environments where signal integrity is required during a fire.Installation in tunnels, subways etc.
Fire Survival Cables contain up to 24 individually identifiable fibers within a single gel filled loose tube, which is then strengthened with E-glass strength members andoversheathed with an ULSZH jacket. The cable is further protected by a layer of corrugated steel tape and a second jacket of ULSZH material. This cable has beendeveloped specifically to meet the requirements of IEC 60794 and IEC 60331-25 (circuit integrity).
Mechanical Characteristics – Fire Survival
Cable Nominal Nominal Installation Min. Installation Static Combustion Part NumbersType Cable OD Weight Tension Bend Radius Bend Radius Energy
(mm) (kg/km) (N) (mm) (mm) (MJ/m) 50/125 µm 62.5/125 µm 9/125 µm
4f 12.7 216 1400 255 180 6.20 Y-1594715-5 Y-1594708-5 0-1594711-5
6f 12.7 216 1400 255 180 6.20 Y-1594757-5 Y-1594758-5 0-1594759-5
8f 12.7 216 1400 255 180 6.20 Y-1594716-5 Y-1594760-5 0-1594712-5
12f 12.7 216 1400 255 180 6.20 Y-1594717-5 Y-1594709-5 0-1594713-5
16f 12.7 216 1400 255 180 6.20 Y-1594761-5 Y-1594762-5 0-1594763-5
24f 12.7 216 1400 255 180 6.20 Y-1594718-5 Y-1594710-5 0-1594714-5
Standard sheath color black: Part Number suffix -5
Outer LSZH jacket
Corrugated steel tape armoring
E-glass strengthmembers
Gel filled loose tubecontaining up to 24,250 µm optical fibers
Inner ULSZH jacket
Fiber and buffer colors (TIA/EIA 568)
1–4 blue, orange, green, brown5–8 grey, white, red, black9–12 yellow, violet, pink, turquoise
13–16 (16 fiber cables – loose tube) magenta, olive, dark green, natural13–24 (24 fiber cables – unitube) as 1–12, then same colors banded,
except black replaced by natural banded
Y- Bandw. Cat.
2- 500/500 OM2
7- 600/1200 OM2 750
8- 1500/500 OM3
9- 3500/500 OM4(OFL)
Y- Bandw. Cat.
0- 200/600 OM1
7- 350/600 OM1 500
Field Deployable Cable
Optional designs (on request):
– Flame retardant polyurethane sheath
Standards:
IEC 60794ISO 11801Cable properties IEC 60794
Features:
l Highly flexiblel Excellent crush resistance: 2000Nl Compact construction for optimum
space utilisationl Longitudinal and lateral water blockingl Very durablel Wide temperature range:
Transport/storage: –40 °C to +70 °CInstallation: –5 °C to +50 °COperation: –40 °C to +70 °C
l Chemical resistance
Applications:
This cable is designed for applicationswhere a rugged flexible communicationslink is required, for example temporarycommunication links for broadcasting liveevents such as sports and media events,military and industrial applications, mobileantennas etc. The cable can be deployedand retrieved with ease due to its highlyflexible and durable nature.
Field deployable cables contain up to 4 individually identifiable, 900 µm tight buffered fibers. They are strengthened with aramid yarn strength members andoversheathed with polyurethane material. This cable has been developed specifically to meet the requirements of IEC 60794 parts 1 & 2.
Mechanical Characteristics – Field Deployable Cable
Cable Nominal Nominal Installation Min. Installation Static Combustion Part NumbersType Cable OD Weight Tension Bend Radius Bend Radius Energy
(mm) (kg/km) (N) (mm) (mm) (MJ/m) 50/125 µm 62.5/125 µm 9/125 µm
2f 5.8 28 1200 70 35 0.70 Y-1594377-5 Y-1594403-5 0-1594765-5
4f 5.8 28 1200 70 35 0.70 Y-1594643-5 Y-1594417-5 0-1594538-5
Standard sheath color black: Part Number suffix -5
Polyurethane jacket
Aramid strength members
Tight 900 µm buffer
Fiber and buffer colors (TIA/EIA 568)
1–4 blue, orange, green, brown
Y- Bandw. Cat.
2- 500/500 OM2
7- 600/1200 OM2 750
8- 1500/500 OM3
9- 3500/500 OM4(OFL)
All specifications subject to change. Consult Tyco Electronics for latest specifications. 9
Y- Bandw. Cat.
0- 200/600 OM1
7- 350/600 OM1 500
1308777-3–2M–HWO–09/10 © 2010 – Tyco Electronics – All rights reservedTE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of www.tycoelectronics.comcompanies and its licensors.
North AmericaGreensboro, NC, USAPh: +1-800-553-0938Fx: +1-717-986-7406
Latin AmericaBuenos Aires, Argentina Ph: +54-11-4733-2200Fx: +54-11-4733-2285
EuropeKessel-Lo, BelgiumPh: +32-16-35-1321Fx: +32-16-35-2188
Mid East & AfricaCergy-Pontoise, FrancePh: +33-1-3420-2122Fx: +33-1-3420-2268
AsiaHong Kong, ChinaPh: +852-2735-1628Fx: +852-2735-1625
PacificSydney, AustraliaPh: +61-2-9554-2600Fx: +61-2-9554-2519
TE Enterprise Networks Regional Sales Headquarters:
Austria – ViennaPh: +43-1-90560-1204Fx: +43-1-90560-1270
Belarus — MinskPh: +375-17-237-4794Fx: +375-17-237-4794
Belgium —Kessel-LoPh: +32-16-35-2326Fx: +32-16-35-2353
Bulgaria – SofiaPh: +359-2-971-2152Fx: +359-2-971-2153
Czech&Slovak Rep.–KurimPh: +420-541-162-112Fx: +420-541-162-223
Denmark – GlostrupPh: +45-70-15-52-00Fx: +45-43-44-14-14
Egypt – CairoPh: +20-2-2419-2334Fx: +20-2-2417-7647
Finland – HelsinkiPh: +358-95-12-34-20Fx: +358-95-12-34-250
France – Cergy-Pontoise Ph: +33-1-3420-2122Fx: +33-1-3420-2268
Germany – LangenPh: +49-6103-709-1547Fx: +49-6103-709-1219
Greece/Cyprus – AthensPh: +30-210-9370-396Fx: +30-210-9370-655
Hungary – BudapestPh: +36-1-289-1007Fx: +36-1-289-1010
India – BangalorePh: +91-80-4011-5000Fx: +91-80-4011-5030
Italy – Collegno (Torino)Ph: +39-011-4012-111Fx: +39-011-4012-268
Kazakhstan – AlmatyPh: +7-327-244-5875Fx: +7-327-244-5877
Lithuania – VilniusPh: +370-5-213-1402Fx: +370-5-213-1403
Netherlands –Den BoschPh: +31-73-6246-246Fx: +31-73-6246-958
Norway – NesbruPh: +47-66-77-88-99Fx: +47-66-77-88-55
Poland – WarsawPh: +48-22-4576-700Fx: +48-22-4576-720
Portugal – EvoraPh: +351-961-377-331Fx: +351-211-454-506
Romania – BucharestPh: +40-21-311-3479Fx: +40-21-312-0574
Russia – MoscowPh: +7-495-790-7902Fx: +7-495-721-1894
Spain – BarcelonaPh: +34-93-291-0330Fx: +34-93-291-0608
Sweden–UpplandsVäsbyPh: +46-8-5072-5000Fx: +46-8-5072-5001
Switzerland – SteinachPh: +41-71-447-0-447Fx: +41-71-447-0-423
Turkey – IstanbulPh: +90-212-281-8181Fx: +90-212-281-8184
UK – Stanmore, MiddxPh: +44-208-420-8140Fx: +44-208-954-7467
Ukraine – KievPh: +380-44-206-2265Fx: +380-44-206-2264
U.A.E. – DubaiPh: +971-4-321-0201Fx: +971-4-321-6300
TE Enterprise Networks in Europe, Middle East, Africa and India:
top related