excom®

Remote I/O in Zone 1

excom®

excom®

One system for all requirementsin Zone 1

excom®

• Supply unit concept

• System connection

• Module overview

• Binary signal detection

• Analogue signal detection

• Housings

• Integration in Asset Management Systems

• Overall view of technological advantages

Content

excom®

Supply unit concept

Optimezed Power throughthe use of EEx-e input

AC-supplyingto the Backplane

Design of theBackplane in EEx-m

Galvanically isolated power supply of the modules with power restriction

excom®

Supply unit concept

• Power supply either 24 VDC or 115 / 230 VAC

• Fully redundancy• Exchange in Zone 1 during

operation• 1 Supply unit is sufficient to

supply a full equipped module rack

excom®

Supply unit concept

24 VDC

• 1 Supply unit• 1 Supplyline

18-33 VDC

excom®

Supply unit concept

24 VDC

18-33 VDC

• 2 Supply unit• 1 Supplyline

excom®

Supply unit concept

24 VDC

18-33 VDC

• 2 Supply unit• 2 Supplyline

18-33 VDC

excom®

Supply unit concept

115 / 230VAC

• Same possibilities as with 24VDC• Upgrade from an existing

24VDC- module rack possible

excom®

Supply unit concept

mixed supply

115 / 230 VAC and 24 VDC

115 / 230 VAC

18-33 VDC

excom®

System connection

• Intrinsically safe Profibus DP Gateway

• Profibus DP-V1• Fully redundancy• LED indication• Hot swappable• Configuration over Profibus• HART®-over-Profibus

excom®

System connection

with copper cable

DP

SC12EX

RS 485 RS 485 iS

Zone 1

max: 31 devices

Control system

excom®

System connection

with Fibre Optic Cable

DP

RS 485

max: 31 devices

RS 485 iS

OC11Ex/3G

OC11Ex/2G

LWL iS

Zone 1Control system

excom®

System connection

with Fibre Optic Cable

DP

RS 485

Link cable

Zone 1

LWL iS

OC11Ex/3G

2 x OC11Ex/2G

OC11Ex/2G

RS 485 iS

max: 31 devices

max: 31 devices

Control system

excom®

System connection

Redundancy possibilities

DP

SC12EX Zone 1

• 1 Control system

• 1 Profibus Master

Control system

excom®

System connection

Redundancy possibilities

DP

SC12EX

DP

SC12EX

Zone 1

• 1 Control system

• 2 Profibus Master

Control system

excom®

Control system B

System connection

Redundancy possibilities

DP

SC12EX

SC12EX

DP

Zone 1

• 2 Control systems

• each 1 Profibus Master

Control system A

excom®

Module overview

AIH40Ex

AIH41Ex

Other devices

in preparation

DM80Ex

DF20Ex AO40Ex

AOH40Ex

TI40Ex

Modules for:

• NAMUR-sensors and actuators• mechanical contacts• temperature sensors, thermocouplers• analogue input-/outputs signals• HART® -signal transmission

DI40Ex

DO40Ex

AI40Ex

AI41Ex

excom®

Binary signal detection

• 8 channels• For connection either of

NAMUR-sensors and actuators or mechanical contacts

• Input- and Output channels configurable

• Designed for connecting low power valves

• Configurable on/off delay in the range of 2...100 ms possible for each channel

In-/output module – DM80Ex

excom®

Binary signal detection

Input module – DI40Ex

• 4 channels• Galvanic isolation between

the channels• For connection either of

NAMUR sensors or mechanical contacts

• Configurable on/off delay in the range of 2...100 ms possible for each channel

excom®

Binary signal detection

Output module – DO40Ex

• 4 channels• Galvanic isolation between

the channels• automatic adjustment of

power in the range of:10..24 VDC

• Typical connected loads:24 V/6 mA18 V/25 mA15 V/35 mA12 V/45 mA

excom®

Binary signal detection

Frequency module – DF20Ex

• 2 channels• Counter or Frequency input• Up to 4 kHz• 2 main inputs with 3 control

in-/outputs• Control inputsfor:

- direction detection- reset input- release input

excom®

Analogue signal detection

Input module – AIH40Ex

• 4 channels• Integrated HART® Controller• For connection of 2-wire-

transducer• 14 Bit-resolution

0..21 mA is reproduced as a figure between 0 and 21000

• Up to 8 HART® Variables in cyclic communication

excom®

Analogue signal detection

Input module – AIH41Ex

• 4 channels• Integrated HART® Controller• For connection of 4-wire-

transducer• 14 Bit-resolution

0..21 mA is reproduced as a figure between 0 and 21000

• Up to 8 HART® Variables in cyclic communication

excom®

Analogue signal detection

Input module – AI40Ex

• 4 channels• Galvanic isolation between

the channels• For cennection of 2- and 4-

wire-transducers• 14 Bit-resolution

0..21 mA is reproduced as a figure between 0 and 21000

excom®

Analogue signal detection

Input module – AI41Ex

• 4 channels• Galvanic isolation between

the channels• For connection of 4-wire-

transducer• Current input 0..21mA

Voltage input 0..10,5 V• 14 Bit-resolution

0..21 mA is reproduced as a figure between 0 and 21000 0..10,5 V is reproduced as a figure between 0 and 10500

excom®

Analogue signal detection

Output module – AOH40Ex

• 4 channels• Integrated HART® Controller• For connection of

0/4..20 mA actuators• 12 Bit-resolution

0..21 mA is reproduced as a figure between 0 and 21000

• Up to 8 HART® Variables in cyclic communication

excom®

Analogue signal detection

Output module – AO40Ex

• 4 channels• Galvanic isolation between

the channels• For connection of

0/4..20 mA actuators• 13 Bit-resolution

0..21 mA is reproduced as a figure between 0 and 21000

• At connected HART® devices the parameterization will be done direct on the device

excom®

Analogue signal detection

Temperature module – TI40Ex

• 4 channels• Galvanic isolation between

the channels• Resistant- or thermocoupler

measurement• 16 Bit-resolution

0,1 K per Digit from 0 Kelvin upwards

• Channelwise external cold junction compensation or internal for all

excom®

Housings

• Using in Zone 1• Stainless steel cabinet with

window• Mounting rail for module rack• 2 Cu-shield bus• Flange plate with cable

glands• Mounting of 1 x MT18

or 2 x MT9• IP65

excom®

Housingswith system approval

excom®

Housingswith system approval

Temperature calculation with Excel

• Download from www.turck.com• Selection of the used modules• Automatic calculation of the power

consumption• Selection of the max. ambient temperature

excom®

Housingswith system approval

excom®

Housingswith system approval

excom®

Housingscustomerized solutions

excom®

Housingscustomerized solutions

excom®

• Emerson AMS® Suite

• FDT/DTM Technology

Integration inAsset Management Systems

excom®

DTM’s

HART® Communication with FDT/DTM

excom®

HART® Communication with FDT/DTM

As with PACTware®

• Download from PACTware® (www.turck.com)• Download of the DTMs from the sites of the

manufactors• Installation of PACTware® and DTMs• Build up a project:

→ CommDTM→ excom® DTM→ Geräte DTMs

• Start!

excom®

HART® Communication with FDT/DTM

excom®

Integration in Emerson AMS® suite

excom®

Overall view of technological advantages

• Non-restrictive Power redundancy in Zone 1

• Gateway redundancy

• Status Indication via LED

• Hot Swap for all components in Zone 1

• Minor volume dimensions

excom®

Overall view of technological advantages

• One binary output module for quite all intrinsic safe valves

• One temperature module für all current temperature sensors and thermocpouplers

• Continuous HART® Ccmmunication

excom®

Thank you very much for your kind attention.