excavations: excavations to comply with sans ......farm 117/216 uitzicht farm 117/216 uitzicht site...
Post on 24-Aug-2021
1 Views
Preview:
TRANSCRIPT
DN
Boundary Line 236 150
Boundary Line 82 940
Boun
dary
Lin
e 2
16 5
50
A.C Strydom Street Boundary Line 309 190
Boundary Line 298 180
Erf 216/116
Dolley Raats Street
Erf 216/118
Erf 216/117
Existing Dwelling
Existing Retaining Wall
Existing Dwelling
Proposed New Workshop/ Garage & Guest Accommodation
Existing JOJO TANKS
Boundary Line 67 580
30000
BUILDIN
G LIN
E 30m
Existing retaining walls to be demolished
New retaining walls to engineer spec
Existing Soakaway
Existing Septic Tank
Proposed New Roof Over Existing Staircase
New location of existing platform
Elevated Wooden Deck to be relocated
re
Proposed New Septic Tank
Proposed New Soakaway
re
Proposed New Septic Tank
Proposed New Soakaway
Existing Pool paved
platformExisting Patio to be covered with cement roof/slab and timber sunshade to abut slab
Existing Septic Tank
Existing Soakaway
Fullbore70133
4398
5
BUILDING LINE 30m
BUILDING LINE 30m
BUILDING LINE 30m
BUIL
DIN
G L
INE
30m
Garage 2
Existing Soakaway
Existing Septic Tank
Existing Pool
paving
paving
paved platform
pump
Paved Driveway
"BM"167.90
Lamp
Existing Retaining Walls
168m
169m
170m
171m
172m
173m
174m
175m
176m
176m
175m
174m
173m17
2m
171m
170m
169m
168 m
167m
166m
165m
164m
163m
162m
161m
161m
162m
163m
164m165m
166m 167m
Shed
Existing Retaining Wall
JOJO TANKS
Elevated Wooden Deck to be relocated
Boundary Line 298 180
Erf 216/118
30000
Existing Dwelling
Proposed New Workshop/ Garage
New location of existing platform
Proposed New Roof Over Existing Staircase
re
New sewer lin
e 110mmØ sewer lin
e
re
Proposed New Septic Tank
Proposed New Soakaway
New Parking
12
34
Scale
Date
Drawn
Checked
CLIENT DETAILS:
PROJECT DETAILS:
PURPOSE OF ISSUE:
Project Number Drawing Number
Revision
BJG
Client's Signature
Knysna Office:
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen&
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen
PL A N S U SA R C H I T E C T U R A L E R V I C E SS
COPYRIGHTThis drawing is protected by the Copyright Act No 98 of 1978 andmay not be used or reproduced in any form whatsoever withoutthe written consent of Plans R Us. The designs herein remain theproperty of Plans R Us unless otherwise explicitly stipulated in thecontract.
This is a CAD generated drawing. Figured dimensions havepreference over scaled dimensions and large scaled drawings supercede small scaled drawings.
CONTRACTORS NOTE:These drawings are issued on the understanding that competentand experienced builders will use them. Contractor is to verify andcheck all levels and boundary pegs on site, and check the sameagainst drawings before putting work in hand. Any errors,discrepancies and omissions to be reported to theArchitect/draughtsman immediately. All work and levels to bestrictly in accordance with SABS 0400 requirements and Councilregulations. No work to encroach site boundaries. Site is to bekept neat and all unnecessary rubble to be moved off sitetimeously. Levels of adjacent site are to be re-instated wheredisturbed after completion of work.
OCCUPANCY CLASS: H4 - DWELLING HOUSE
20 Eastford Ridge, Welbedacht, 6570Telephone: 044 386 0127 Cellular: 082 457-7616
Email: sheldon@plansrus.co.za
As shown
SHEET NAME:
FS/SvO
ZONING: AGRICULTURAL
Note:
Submission
Peter Pickering
House Pickering
14/01/2021
Kny 124 P1 of 6
Farm 117/216 Uitzicht
Farm 117/216 Uitzicht
Site Plan
1 : 1000Site Plan
1 : 500Dwelling Topo
SITE : OPERATIONS TO COMPLY WITH SANS 10400 - F:• ONCE SITE HAS BEEN CLEARED, BUILDER TO ARRANGE A CERTIFIED LAND SURVEYOR TO VERIFY BOUNDARY PEGS AND
TO SITE THE DWELLING.• SITE TO BE TREATED IN ACCORDANCE WITH S.A.B.S. CODE OF PRACTICE NO. 0124-1977 WITH "SHELLDRITE" TERMITE
PROOF SOIL POISON OR SIMILAR.• TOPSOIL TO BE PUT TO ONE SIDE FOR LATER USE.
EXCAVATIONS: EXCAVATIONS TO COMPLY WITH SANS 10400 - G• ALL LEVELS AS PER DRAWINGS. • EXCAVATION WORK INCLUDING CUT AND FILL TO BE CARRIED OUT AS PER DRAWING.• TRENCHING FOR FOUNDATIONS TO BE EXCAVATED TO FIRM NATURAL GROUND EXCEPT WHERE FILL IS REQUIRED
WHICH MUST BE TO ENGINEER DETAIL.• TRENCHING FOR PIPES, CABLE ETC TO BE A MINIMUM OF 450mm BELOW GROUND LEVEL AND TO BE KEPT TO A
MINIMUM.
ROOF: ROOF TO COMPLY WITH SANS 10400 - L:• ROOFS TO MATCH EXISTING.• STAIRCASE ROOF: CONCRETE ROOF TILES TO MATCH EXISTING ON 38X38mm BATTENS ON 12 MM SHUTTERPLY ON
150X50mm TIMBER STRUCTURE SUPPORTED BY POSTS AS PER ENGINEER'S SPECIFICATIONS• FIRST FLOOR ROOF: CEMENT ROOF TILES (TO MATCH EXISTING) ON 38X38mm S.A. PINE PURLINS AT 380mm CENTRES
ON GANGNAILED ROOF TRUSSES TO MANUFACTURERS SPEC ON 114X38MM WALLPLATES FIXED WITH GALVANISED HOOP IRONS BUILT MIN 600mm INTO BRICKWORK AND HAVE CELLULOSE FIBRE (AEROLITE TYPE OR SIMILAR) OF MIN 150mm WITH AN R-VALUE OF 3.36 AS PER SANS XA INSTALLED BY SPECIALIST
• "NUTEC" OR SIMILAR FASCIA AND BARGE BOARDS TO MATCH EXISTING.• SUNSHADE: TIMBER SUNSHADE BY SPECIALIST TO ENGINEER SPEC. • SLAB/ROOF: CONCRETE SLAB TO HAVE FULLBORE DRAINS TO ENGINEER SPEC BY SPECIALIST.• DWELLING ROOF: CEMENT ROOF TILES (TO MATCH EXISTING) ON 38x38mm S.A. PINE PURLINS AT 380mm CENTRES
ON GANGNAILED ROOF TRUSSES TO MANUFACTURERS SPEC ON 114x38mm WALLPLATES FIXED WITH GALVANISED HOOP IRONS BUILT MIN 600mm INTO BRICKWORK AND HAVE CELLULOSE FIBRE (AEROLITE TYPE OR SIMILAR) OF MIN150mm WITH AN R-VALUE OF 3.36 AS PER SANS XA INSTALLED BY SPECIALIST
• ROOF STRUCTURE TO BE DESIGNED AND SIGNED OFF BY COMPETENT PERSON.
RAINWATER GOODS: STORM-WATER TO COMPLY WITH SANS 10400 - R:• GUTTERS AND DOWN-PIPES TO MATCH EXHIBITING.• ALL STORM WATER TO BE CHANNELED INTO GARDEN BY SPECIALIST.
WALLS: WALLS TO COMPLY WITH SANS 10400 - K:• 280mm CAVITY WALLS CONSISTING OF A 110mm INSIDE AND OUTSIDE SKIN WITH 60mm CAVITY TIED TOGETHER WITH
BUTTERFLY WIRE-TIES, 3 (THREE) PER m² AND BRICKFORCE EVERY 5TH COURSE. • CAVITIES TO BE KEPT CLEAN OF ALL MORTAR AND FLUSHED OUT AT THE END OF EACH DAY.• EXTERNAL WALLS TO MATCH EXISTING.• ALL INTERNAL WALLS TO BE SMOOTH PLASTER AND PAINTED TO OWNER SPEC.• THERE MUST BE A CONTINUOUS DPC AT SLAB LEVEL AND DPM AROUND ALL EXTERNAL DOORS AND WINDOWS.• "STRESSO" OR SIMILAR PRE-STRESSED LINTELS OVER ALL WINDOW AND DOOR OPENINGS WITH A MINIMUM OF 4
BRICK COURSE AND BRICKFORCE ABOVE.
FOUNDATIONS: FOUNDATIONS TO COMPLY WITH SANS 10400 - H:• CONCRETE FOOTINGS OF A STRENGTH NOT LESS THAN 10mpa @ 28 DAYS (1:4:5) UNLESS STIPULATED BY ENGINEER.• STRIP FOUNDATIONS TO BE A MINIMUM OF 700X250mm UNLESS OTHERWISE STIPULATED BY ENGINEER. • THE TOP OF ANY FOUNDATION TO BE A MINIMUM OF 500mm BELOW NATURAL GROUND LEVEL.
FLOORS: FLOORS TO COMPLY WITH SANS 10400 - J:• FLOORS TO BE 25mm SCREED ON A 100mm CONCRETE BED ON 250 MICRON DPC ON 50mm SAND BED ON WELL
COMPACTED HARDCORE.• FIRST FLOOR SLAB TO ENGINEER SPEC.• FLOOR FINISH AS PER PLAN TO OWNER SPECIFICATION.• HARDCORE FILLING UNDER SURFACE BED TO CONSIST OF EARTH, SAND OR OTHER ACCEPTABLE MATERIAL BUT MUST
BE FREE OF CLAY AND ORGANIC MATTER AND TO BE WELL COMPACTED IN LAYERS NOT EXCEEDING 150mm.• ALL PAVING TO MATCH EXHIBITING.• CEILING: TO COMPLY WITH SANS 10400 PART T4.13:• "NUTEC CEILING OR SIMILAR ON 38X38mm S.A.PINE BATTENS ON MAX 400mm CENTRES.
WINDOWS, DOORS & GLAZING: GLAZING TO COMPLY WITH SANS 10400 - N:• FINISH AS PER WINDOW SCHEDULE.• GARAGE DOORS TO MATCH EXHIBITING AND TO BE AUTOMATED BY SPECIALIST.• GLAZING TO BE IN ACCORDANCE WITH SANS 0400 PART N. OBSCURE GLASS TO BATHROOMS, ALL OTHER GLASS TO
BE CLEAR.• SAFETY GLAZING TO DOORS AND WINDOWS IN EXCESS OF 1m² OR LESS THAN 500mm ABOVE FLOOR LEVEL IN
ACCORDANCE TO PART N 4.4 OF SANS 10400.
DRAINAGE: DRAINAGE TO COMPLY WITH SANS 10400 - P:• ALL WASTE PIPE TO BE A MINIMUM 110mmØ.• WITH THE EXCEPTION OF INSPECTION EYES AND VENT PIPES, NO WASTE PIPES TO BE VISIBLE ON THE EXTERNAL WALL
SKIN AND MUST BE CONCEALED WITHIN THE WALL.• WHERE RODDING EYES ARE INSTALLED ON DRIVEWAY, OR THE LIKE, THEY ARE TO BE RECESSED AND COVERED WITH A
CAST IRON COVER-PLATE.• RODDING EYES TO BE INSTALLED AT EVERY BEND GREATER THAN 90°, ALONG PIPE LINES AT INTERVALS NOT
EXCEEDING 25m AND AT THE START OF EVERY WASTE PIPE RUN.• WHERE WASTE PIPE PASSES UNDER A BUILDING AND HEAVY TRAFFIC AREAS (MOTOR VEHICLE) IT MUST BE OF HIGH
DENSITY PVC ENCASED IN 150mm CONCRETE ALL ROUND.• ALL SANITARY FITTINGS TO BE INSTALLED WITH A TRAP TO COMPLY WITH LOCAL AUTHORITY REGULATIONS.• PLUMBER TO CHECK DRAWING FOR ANY TRADE DISCREPANCIES BOTH INTERNAL AND SUBTERRANEAN.
WATER HEATING:• 50% BY VOLUME OF AVERAGE HOT WATER HEATING REQUIREMENTS SHALL BE PROVIDED BY AN ALTERNATE HEATING
SYSTEM OTHER THAN ESCOM, SUPPLIED AND INSTALLED BY SPECIALIST IN ACCORDANCE WITH SANS 10254 AND SANS 10400 PART XA. ALL HOT WATER SERVICE PIPES TO BE LAGGED AND INSTALLED WITH INSULATING MATERIAL WITH A MINIMUM "R" VALUE OF 1. HOT WATER CYLINDER TO BE INSULATED WITH A NON COMBUSTIBLE LIGHTWEIGHT -"ISOVAR" OR SIMILAR APPROVED MATERIAL WITH AN "R" VALUE OF 2 TO COMPLY WITH SANS 1387.
LIGHTING: LIGHTING & VENTILATION TO COMPLY WITH SANS 10400 - O: • ALL AREAS TO BE ARTIFICIALLY ILLUMINATED.• ALL HABITABLE ROOMS TO BE FITTED WITH DOOR AND WINDOWS TO ACHIEVE A MINIMUM 5% OR 0.1m² NATURAL
VENTILATION AS PER 4.3.1.1.3 OF PART O• ALL LIGHT FITTINGS TO OWNER SPECIFICATION.
857071.13%
UP
23026355230
26815
6040
230
230
6040
230
6200
6500
6270
16425
RC Beam over to engineer spec
Wall to be removed
1000
159.18 m²
Garage/ Workshopgrano
A
P5 of 6
A
P5 of 6
B
P5 of 6
B
P5 of 6
New roof over existing staircase
5317 5317 5317 5317 5317
29551040118024401180104011804880300
Entrance Portico to be enclosed
Existing Garage
Existing Entrance Portico
370
900
1460
2440
2253 1040 4277 1040 4277 1040 4277 1040 4277 1040 225315
60
W623
W629
W624 W6
25W626
W627
W628
13
D6
14
D7
15
D7
16
D9
reNew sewer line 110mmØ sewer line
Existing Veranda
Existing Studio
Existing Office
Existing Library
Existing Entrance Foyer
Existing Kitchen
Existing Dining
Existing Lounge
Existing Veranda
Existing Pantry
ExistingScullery Existing
Cold Room
Existing Passage
Existing Laundry
Existing Staff Canteen
Existing Staff Ambulation
Existing Staff Rest Room
Existing Storage
Existing Storage
Existing Pool Ablution /Change Room
Existing Enclosed Courtyard
Existing Pub Room
3257 2600 2928 2928 2928 2928 2928 2600 3257
DP DP DP DP DP DP DP DP
600
600
2420
2420
DP
DP
DP
DP DP DP
DP
DP2W
2W
Electrical plug point on a ceiling racking system to owner specification
Electrical plug point on a ceiling racking system to owner specification
ELECTRICAL LEGENDWALL LIGHT
LED FIXED DOWNLIGHT
1800 DOUBLE FLUORESCENT LIGHT
LIGHT SWITCH
2 WAY LIGHT SWITCH2W
DP DOUBLE SWITCHED SOCKET 220V1300mm above floor
Scale
Date
Drawn
Checked
CLIENT DETAILS:
PROJECT DETAILS:
PURPOSE OF ISSUE:
Project Number Drawing Number
Revision
BJG
Client's Signature
Knysna Office:
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen&
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen
PL A N S U SA R C H I T E C T U R A L E R V I C E SS
COPYRIGHTThis drawing is protected by the Copyright Act No 98 of 1978 andmay not be used or reproduced in any form whatsoever withoutthe written consent of Plans R Us. The designs herein remain theproperty of Plans R Us unless otherwise explicitly stipulated in thecontract.
This is a CAD generated drawing. Figured dimensions havepreference over scaled dimensions and large scaled drawings supercede small scaled drawings.
CONTRACTORS NOTE:These drawings are issued on the understanding that competentand experienced builders will use them. Contractor is to verify andcheck all levels and boundary pegs on site, and check the sameagainst drawings before putting work in hand. Any errors,discrepancies and omissions to be reported to theArchitect/draughtsman immediately. All work and levels to bestrictly in accordance with SABS 0400 requirements and Councilregulations. No work to encroach site boundaries. Site is to bekept neat and all unnecessary rubble to be moved off sitetimeously. Levels of adjacent site are to be re-instated wheredisturbed after completion of work.
OCCUPANCY CLASS: H4 - DWELLING HOUSE
20 Eastford Ridge, Welbedacht, 6570Telephone: 044 386 0127 Cellular: 082 457-7616
Email: sheldon@plansrus.co.za
As shown
SHEET NAME:
FS/SvO
ZONING: AGRICULTURAL
Note:
Submission
Peter Pickering
House Pickering
14/01/2021
Kny 124 P2 of 6
Farm 117/216 Uitzicht
Farm 117/216 Uitzicht
Ground Floor & Electrical Plan
1 : 100Ground FLoor Plan
1 : 100Ground Floor - Electrical
1 : 100Electrical symbols ALL ELECTRICAL
DN
Existing window to be removed, opening to be bricked up and made good
Existing door to be removed, opening to be bricked up and made good
Existing window to be removed, opening to be bricked up and made good
Existing platform to be moved
New location of existing platform
New door
230
230
6040
230
6500
6500
1230
230
1000
230
2900
115
3025
230
230 4158 115
2000
115
1000
230 3773 115 1385 115 2000 230 2958 115
2000
115 2200 230 3740
23085
12.06 m²
Bedr 1to owner spec
4.00 m²
En-Suite 1to owner spec
27.27 m²
Loungeto owner spec
26.56 m²
Loungeto owner spec
12.50 m²
Bedr 2to owner spec
4.40 m²
En-Suite 2to owner spec
24.66 m²
Loungeto owner spec
1000
230738823073882307388229
A
P5 of 6
A
P5 of 6
B
P5 of 6
B
P5 of 6
23.45 m²
Uncovered Deckto owner spec
New roof over existing staircase
Existing Entrance Portico to be enclosed with glass
1
C1
C22
C33
C44
C55
C56
600 419 950 255 950 800 3838 600
5003481500348150034815003481499999
911
1538
2037
2013
1189 894 1040 1353 542 3024 1040 1306 1040 1540 1538 1721 1538 975 600
980
1800
828
2036
C67
C68
C69W1
10
W111
W112
W213
W314
W415
W516
W617
W618
W219
W220
W121
W722
1
D1
2
D1
3
D1
4
D1
5
D2
6
D3
7
D8 8
D4
9
D310
D2 17
D3
11
D212
D5
12.08 m²
Passageto owner spec
14.57 m²
Bedr 3to owner spec
4.00 m²
En-Suite 3to owner spec
Staircase to engineer spec
Existing Lecture/ Audio/ Display
bic
bic
bic
18
D1
Timber Platform
Coffee Station
Cof
fee
Stat
ion
Coffee Station
wc
shrhwb
PrepBowl
wcshr
hwb
PrepBowlshrwc
hwb
Existing Landing
Existing Main Bedroom
Existing En-SuiteExisting Dressing
Existing Double Volume
Existing Family Room Existing Bedroom 1 Existing Bedroom 2
Existing Bathr. 2
Existing Bathr. 3
Existing Bedr 3Existing Passage
Existing Dressing
Existing Balcony
PrepBowl
ELECTRICAL LEGENDEXTERNAL AUTO LIGHT
WALL LIGHT
LED FIXED DOWNLIGHT
1800 DOUBLE FLUORESCENT LIGHT
LIGHT SWITCH
DOUBLE SWITCHED SOCKET
TV SOCKET OUTLET
2 WAY LIGHT SWITCH2W
AL
DP
TV
CEILING MOUNTED FAN & SINGLE LIGHT
1200mm above floor
DOUBLE SWITCHED SOCKET350mm above floor
CEILING LIGHT
H.W.C. SOLAR GEYSER -geyser in roof space
DP
EXTRACTOR FAN
TV/FIBRE/TEL TV/FIBRE/TEL
DP DOUBLE SWITCHED SOCKET 220V1300mm above floor
SP2 PRONG SHAVER PLUG POINT
SCONCE TYPE LIGHTING FIXTURE
2W
2W
2W
2W
2W
2W 2W
SP
SP
SP
H.W.C.
TV/F
IBR
E/TE
L
TV/FIBRE/TEL
TV/F
IBR
E/TE
L
DP DP
DP
DP
DP
DP
DP
DP
DP D
PD
P
DP
DP
DP
DP
DP
DP
2W
AL
Scale
Date
Drawn
Checked
CLIENT DETAILS:
PROJECT DETAILS:
PURPOSE OF ISSUE:
Project Number Drawing Number
Revision
BJG
Client's Signature
Knysna Office:
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen&
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen
PL A N S U SA R C H I T E C T U R A L E R V I C E SS
COPYRIGHTThis drawing is protected by the Copyright Act No 98 of 1978 andmay not be used or reproduced in any form whatsoever withoutthe written consent of Plans R Us. The designs herein remain theproperty of Plans R Us unless otherwise explicitly stipulated in thecontract.
This is a CAD generated drawing. Figured dimensions havepreference over scaled dimensions and large scaled drawings supercede small scaled drawings.
CONTRACTORS NOTE:These drawings are issued on the understanding that competentand experienced builders will use them. Contractor is to verify andcheck all levels and boundary pegs on site, and check the sameagainst drawings before putting work in hand. Any errors,discrepancies and omissions to be reported to theArchitect/draughtsman immediately. All work and levels to bestrictly in accordance with SABS 0400 requirements and Councilregulations. No work to encroach site boundaries. Site is to bekept neat and all unnecessary rubble to be moved off sitetimeously. Levels of adjacent site are to be re-instated wheredisturbed after completion of work.
OCCUPANCY CLASS: H4 - DWELLING HOUSE
20 Eastford Ridge, Welbedacht, 6570Telephone: 044 386 0127 Cellular: 082 457-7616
Email: sheldon@plansrus.co.za
As shown
SHEET NAME:
FS/SvO
ZONING: AGRICULTURAL
Note:
Submission
Peter Pickering
House Pickering
14/01/2021
Kny 124 P3 of 6
Farm 117/216 Uitzicht
Farm 117/216 Uitzicht
1st Floor Plans & Electrical Layout
1 : 100First Floor Plan
1 : 100First Floor - Electrical
Ground Floor FFL169130.0
First Floor FFL172130.0
03 Ground Floor CH171930.0
05 First Floor CH174730.0
exist
ing existing
exist
ing
exist
ing existing
exist
ing existing
exist
ingexisting
exist
ing existing
exist
ing
existing existing
exist
ing
existing
exist
ing
existing
exist
ing
existing
ffl
exist
ing
Existing Dwelling
Ground Floor FFL169130.0
First Floor FFL172130.0
03 Ground Floor CH171930.0
05 First Floor CH174730.0
exist
ing
exist
ing existing
exist
ing existing
exist
ing
exist
ing
exist
ing
exist
ing
exist
ing
exist
ing
exist
ing
exist
ing
Plaster and paint to match existing
ffl
Existing Dwelling
existing
W72212
D5
15
D7
16
D9
Existing Ground Level
Ground Floor FFL169130.0
First Floor FFL172130.0
03 Ground Floor CH171930.0
05 First Floor CH174730.0
existing
exist
ing
Plaster and paint to match existing
ffl
Existing Dwelling
7
D8 W415
W516
W617 8
D4 W618
W219
W220
W121
W624
W625
W626
W627
W628
Existing Ground Level
Ground Floor FFL169130.0
First Floor FFL172130.0
03 Ground Floor CH171930.0
05 First Floor CH174730.0
exist
ing
exist
ing
existing
exist
ing
exist
ing existing
existing existing existing
Plaster and paint to match existing
New roof over existing staircase
Existing DwellingC33
4
D1 W213 W3
14
Ground Floor FFL169130.0
First Floor FFL172130.0
03 Ground Floor CH171930.0
05 First Floor CH174730.0
existing
existing existing existing
existing existingexisting
existing
Entrance Portico to be enclosed
New roof over existing staircase
1
C1
C55
C44
Existing Dwelling
Exist
ing
Dw
ellin
g
Ground Floor FFL169130.0
First Floor FFL172130.0
03 Ground Floor CH171930.0
05 First Floor CH174730.0
W629
W623
C67
C68
C69
14
D7
13
D6
Existing Dwelling
1000
1000
Scale
Date
Drawn
Checked
CLIENT DETAILS:
PROJECT DETAILS:
PURPOSE OF ISSUE:
Project Number Drawing Number
Revision
BJG
Client's Signature
Knysna Office:
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen&
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen
PL A N S U SA R C H I T E C T U R A L E R V I C E SS
COPYRIGHTThis drawing is protected by the Copyright Act No 98 of 1978 andmay not be used or reproduced in any form whatsoever withoutthe written consent of Plans R Us. The designs herein remain theproperty of Plans R Us unless otherwise explicitly stipulated in thecontract.
This is a CAD generated drawing. Figured dimensions havepreference over scaled dimensions and large scaled drawings supercede small scaled drawings.
CONTRACTORS NOTE:These drawings are issued on the understanding that competentand experienced builders will use them. Contractor is to verify andcheck all levels and boundary pegs on site, and check the sameagainst drawings before putting work in hand. Any errors,discrepancies and omissions to be reported to theArchitect/draughtsman immediately. All work and levels to bestrictly in accordance with SABS 0400 requirements and Councilregulations. No work to encroach site boundaries. Site is to bekept neat and all unnecessary rubble to be moved off sitetimeously. Levels of adjacent site are to be re-instated wheredisturbed after completion of work.
OCCUPANCY CLASS: H4 - DWELLING HOUSE
20 Eastford Ridge, Welbedacht, 6570Telephone: 044 386 0127 Cellular: 082 457-7616
Email: sheldon@plansrus.co.za
As shown
SHEET NAME:
FS/SvO
ZONING: AGRICULTURAL
Note:
Submission
Peter Pickering
House Pickering
14/01/2021
Kny 124 P4 of 6
Farm 117/216 Uitzicht
Farm 117/216 Uitzicht
Elevations
1 : 100North West Elevation
1 : 100North East Elevation
1 : 100South East Elevation
1 : 100South West Elevation
1 : 100South East Elevation - Staircasae
1 : 100North West Elevation - Extension
Ground Floor FFL169130.0
First Floor FFL172130.0
03 Ground Floor CH171930.0
05 First Floor CH174730.0
ffl
Existing Foundation
Existing concrete staircase
Existing balustrade
New brickwork
New timber posts to engineer spec
Concrete roof tiles to match existing on 38x38mm battens on 12 mm shutterply on 150x50mm timber structure supported by posts as per engineer's specifications
Exist
ing
Dw
ellin
gEx
istin
g D
wel
ling
New aluminium windows to match existing
New concrete roof to engineer spec
2246
2366
Enclosed Passage
Existing Landing
Ground Floor FFL169130.0
First Floor FFL172130.0
03 Ground Floor CH171930.0
05 First Floor CH174730.0
New paving to match existing All retaining wall, dampproofing
and subsoil drain by engineer
All foundations to Engineer specification.
Floor Finish as per plan on 25mm screed on 100mmconcrete bed on min 250 micron DPM on 50mm sand blinding on well compacted hardcore.
Skim coated, 6.4mm Nutec or similar on 38x38mm S.A. pine battens on max 400mm centres
CONCRETE SLAB TO ENGINEER SPEC TIMBER WALKWAY AND DECK TO ENGINEER SPEC
Cement roof tiles (to match existing) on 38x38mm S.A. Pine purlins at 380mm centres on gangnailed roof trusses to manufacturers spec on 114x38mm wallplates fixed with galvanised hoop irons built min 600mm into brickwork and have cellulose fibre (Aerolite type or similar) of min 150mm with an R-Value of 3.36 as per SANS XA installed by specialist
min
1000
New balustrade to match existing
2600
3350
1000
2600
2800
Bedr 1 Lounge/ Dining 1
Garage/ Workshop
Timber Platform
Concrete Leveling Pad to engineer spec
Concrete Leveling Pad to engineer spec
Concrete Leveling Pad to engineer spec
1000
1000
1000
1000
1000
1000
Existing Ground Levelcut
cut
Type:
Quantity:
Material:
Description:
C1
1
Aluminium Frame
To match existing
Location of door:
Entrance PorticoNo.: Room:
1
5600
1980
582 813 585
All dimensions to be verified on site
600
5600
Type:
Quantity:
Material:
Description:
C2
1
Aluminium Frame
To match existing
Location of door:
Entrance PorticoNo.: Room:
2
All dimensions to be verified on site
Type:
Quantity:
Material:
Description:
C3
1
Aluminium Frame
To match existing
Location of door:
Enclosed StaircaseNo.: Room:
3
2370
1366
1004
1795
ffl
fflffl
All dimensions to be verified on site
Type:
Quantity:
Material:
Description:
C4
1
Aluminium Frame
To match existing
Location of door:
Enclosed StaircaseNo.: Room:
4
All dimensions to be verified on site
ffl 1104
1366
1115
2470
Type:
Quantity:
Material:
Description:
C5
2
Aluminium Frame
To match existing
Location of door:
Enclosed StaircaseNo.: Room:
5
All dimensions to be verified on site
986
2260
Enclosed Staircase
6
Type:
Quantity:
Material:
Description:
C6
3
Aluminium Frame
To match existing
Location of door:
PassageNo.: Room:
7
All dimensions to be verified on site
ffl 1000
1431
3481
Passage8Passage9
Type:
Quantity:
Material:
Description:
W1
4
Aluminium Frame
To match existing
Location of door:
En-Suite 1No.: Room:
10
Type:
Quantity:
Material:
Description:
W2
3
Aluminium Frame
To match existing
Location of door:
Bedr 1No.: Room:
13
Type:
Quantity:
Material:
Description:
W3
1
Aluminium Frame
To match existing
Location of door:
Lounge/ Dining 1No.: Room:
14
Type:
Quantity:
Material:
Description:
W4
1
Aluminium Frame
To match existing
Location of door:
Lounge/ Dining 1No.: Room:
15
Type:
Quantity:
Material:
Description:
W5
1
Aluminium Frame
To match existing
Location of door:
Lounge/ Dining 1No.: Room:
16
Type:
Quantity:
Material:
Description:
W6
9
Aluminium Frame
To match existing
Location of door:
Lounge/ Dining 2No.: Room:
17
Type:
Quantity:
Material:
Description:
W7
1
Aluminium Frame
To match existing
Location of door:
Lounge/ Dining 3No.: Room:
22
Type:
Quantity:
Material:
Description:
D1
5
Aluminium Frame
To match existing
Location of door:
Lounge/ Dining 1No.: Room:
1
Type:
Quantity:
Material:
Description:
D2
3
Aluminium Frame
Supawood doors for painting to owners spec
Location of door:
En-Suite 1No.: Room:
5
Type:
Quantity:
Material:
Description:
D3
3
Aluminium Frame
Supawood doors for painting to owners spec
Location of door:
Bedr 1No.: Room:
6
Type:
Quantity:
Material:
Description:
D4
1
Aluminium Frame
To match existing
Location of door:
Lounge/ Dining 2No.: Room:
8
Type:
Quantity:
Material:
Description:
D5
1
Aluminium Frame
To match existing
Location of door:
Lounge/ Dining 3No.: Room:
12
Type:
Quantity:
Material:
Description:
D6
1
Timber Frame
To match existing
Location of door:
Garage/ WorkshopNo.: Room:
13
Type:
Quantity:
Material:
Description:
D7
2
Timber Frame
To match existing
Location of door:
Garage/ WorkshopNo.: Room:
14
Type:
Quantity:
Material:
Description:
D8
1
Aluminium Frame
To match existing
Location of door:
Lounge/ Dining 1No.: Room:
7
ffl
210012
00
600
Lounge/ Dining 211En-Suite 212En-Suite 321
ffl
2100
1538
1461
Bedr 219Bedr 320
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Clear
Glazing:Single - Low E
fflSouth West South East
542 2000
1461
1461
1190
1461
1040
ffl
2100
ffl
2100
542
1195
ffl
2100
1040
1461
Lounge/ Dining 218
ffl
2100
2036
1461
Garage/ Workshop23Garage/ Workshop24Garage/ Workshop25Garage/ Workshop26Garage/ Workshop27Garage/ Workshop28Garage/ Workshop29
ffl
2100
900
Lounge/ Dining 22Lounge/ Dining 33Passage4
ffl
800
2100
En-Suite 210En-Suite 311
ffl
900
2100
Bedr 29Bedr 317
ffl
2100
895
Glazing:Single - Clear
Glazing:Single - Clear
ffl
2090
1306
ffl
2100
1800
Glazing:Single - Low E
ffl
2100
4880
Garage/ Workshop15
Type:
Quantity:
Material:
Description:
D9
1
Aluminium Frame
To match existing
Location of door:
Garage/ WorkshopNo.: Room:
16
ffl
2100
900
2542
ffl
2100
2440
f f
f f
f f f
f
f
f f f
f
ff f
f f f f
f
2260
986
f
f
65
Passage18
Scale
Date
Drawn
Checked
CLIENT DETAILS:
PROJECT DETAILS:
PURPOSE OF ISSUE:
Project Number Drawing Number
Revision
BJG
Client's Signature
Knysna Office:
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen&
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen
PL A N S U SA R C H I T E C T U R A L E R V I C E SS
COPYRIGHTThis drawing is protected by the Copyright Act No 98 of 1978 andmay not be used or reproduced in any form whatsoever withoutthe written consent of Plans R Us. The designs herein remain theproperty of Plans R Us unless otherwise explicitly stipulated in thecontract.
This is a CAD generated drawing. Figured dimensions havepreference over scaled dimensions and large scaled drawings supercede small scaled drawings.
CONTRACTORS NOTE:These drawings are issued on the understanding that competentand experienced builders will use them. Contractor is to verify andcheck all levels and boundary pegs on site, and check the sameagainst drawings before putting work in hand. Any errors,discrepancies and omissions to be reported to theArchitect/draughtsman immediately. All work and levels to bestrictly in accordance with SABS 0400 requirements and Councilregulations. No work to encroach site boundaries. Site is to bekept neat and all unnecessary rubble to be moved off sitetimeously. Levels of adjacent site are to be re-instated wheredisturbed after completion of work.
OCCUPANCY CLASS: H4 - DWELLING HOUSE
20 Eastford Ridge, Welbedacht, 6570Telephone: 044 386 0127 Cellular: 082 457-7616
Email: sheldon@plansrus.co.za
As shown
SHEET NAME:
FS/SvO
ZONING: AGRICULTURAL
Note:
Submission
Peter Pickering
House Pickering
14/01/2021
Kny 124 P5 of 6
Farm 117/216 Uitzicht
Farm 117/216 Uitzicht
Sections & Schedule
1 : 50Section A-A
1 : 50Section B-B
1 : 100Window & Door Schedule
Existing Dwelling
fglCottage FFL169130.0
Cottage WP171713.7
New sunshade over existing patio
fglCottage FFL169130.0
Cottage WP171713.7
Existing Dwelling
Existing shower
Existing Dwelling
fglCottage FFL169130.0
Cottage WP171713.7
New sunshade over existing patio
Existing Dwelling
fgl
Cottage FFL169130.0
Cottage WP171713.7
2000
Existing Shower
New sunshade over existing patio
815
230
1000
1200 230
Existing Garage
Existing En-Suite
Existing Bedroom
Existing Bathroom
Existing KitchenExisting
Family Room
Existing DiningExisting Lounge
Existing BedroomExisting BedroomExisting Bedroom
Existing Fireplace
Existing Shower
Door removed, bricked up and made good
4230
4130
C
P6 of 6
C
P6 of 6
380 3060 380 3100 380
Existing Patio to be covered with slab and sunshade
48.48 m²
Covered Patioto owner spec
380
3145
380
2620
380
380 2560
380
2065
Existing Columns edge of slab above
Exist
ing
sew
er li
neC
onne
cts t
o ex
istin
g se
ptic
tank
bey
ond
Fullbore above by specialist
Fullbore above by specialist
Existing Columns
43.37°
46.63°
Angle of i-beam to be verified on site by specialist
I-beam above
I-bea
m a
bove
I-beam above
I-beam above
I-bea
m a
bove
I-bea
m a
bove
I-beam above
(Garage 2)
Cottage FFL169130.0
Cottage WP171713.7
fglExisting Slab
Existing column
Sunshade by specialist to engineer spec
38x38mm purlins with max 38mm gaps
Concrete flat roof to engineer spec. Fall to fullbore outlet to engineer spec by specialist.
Covered Patio
Exist
ing
Dw
ellin
g
Existing Foundation
I-beams to engineer spec
2400
50X152 timber frame with 38x152mm rafters at min 1050 c/c
Scale
Date
Drawn
Checked
CLIENT DETAILS:
PROJECT DETAILS:
PURPOSE OF ISSUE:
Project Number Drawing Number
Revision
BJG
Client's Signature
Knysna Office:
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen&
Pr.S.Arch.T. - Reg. No. ST0685
Bryan J. GillbeeArch. Drght. - Reg. No. CAD41217798
Sheldon van Onselen
PL A N S U SA R C H I T E C T U R A L E R V I C E SS
COPYRIGHTThis drawing is protected by the Copyright Act No 98 of 1978 andmay not be used or reproduced in any form whatsoever withoutthe written consent of Plans R Us. The designs herein remain theproperty of Plans R Us unless otherwise explicitly stipulated in thecontract.
This is a CAD generated drawing. Figured dimensions havepreference over scaled dimensions and large scaled drawings supercede small scaled drawings.
CONTRACTORS NOTE:These drawings are issued on the understanding that competentand experienced builders will use them. Contractor is to verify andcheck all levels and boundary pegs on site, and check the sameagainst drawings before putting work in hand. Any errors,discrepancies and omissions to be reported to theArchitect/draughtsman immediately. All work and levels to bestrictly in accordance with SABS 0400 requirements and Councilregulations. No work to encroach site boundaries. Site is to bekept neat and all unnecessary rubble to be moved off sitetimeously. Levels of adjacent site are to be re-instated wheredisturbed after completion of work.
OCCUPANCY CLASS: H4 - DWELLING HOUSE
20 Eastford Ridge, Welbedacht, 6570Telephone: 044 386 0127 Cellular: 082 457-7616
Email: sheldon@plansrus.co.za
As shown
SHEET NAME:
FS/SvO
ZONING: AGRICULTURAL
Note:
Submission
Peter Pickering
House Pickering
14/01/2021
Kny 124 P6 of 6
Farm 117/216 Uitzicht
Farm 117/216 Uitzicht
Cottage Elevations, Section & Floor Plan
1 : 100North Elevation
1 : 100East Elevation
1 : 100West Elevation
1 : 100South Elevation
1 : 100Ground Floor - Cottage
1 : 50Section C-C
top related