EESIFLO International Pte LtdEESIFLO International Pte Ltd

Product RangeProduct Range

• Ultrasonic Flow meter• Water-in-Oil Monitor• Water-in-Fuel Monitor• BS&W Water Cut Meter• Static Mixer• Oil & Gas Sampling System

EASZ-1 Water-in-Oil MonitorEASZ-1 Water-in-Oil Monitor The online water in oil monitors manufactured by

EESIFLO International were designed to measure water in any form within an oil or hydrocarbon.

The meters can be installed for any type of oil including lubricating fluids, hydraulics, fuel, crude oil and various hydrocarbons and mineral based liquids.

We have paid special attention to the manufacturing of high quality monitors suitable for harsh environments or hazardous areas.

The online water in oil monitors manufactured by

EESIFLO International were designed to measure water in any form within an oil or hydrocarbon.

The meters can be installed for any type of oil including lubricating fluids, hydraulics, fuel, crude oil and various hydrocarbons and mineral based liquids.

We have paid special attention to the manufacturing of high quality monitors suitable for harsh environments or hazardous areas.

How does it works?How does it works?• Oil & Water have dissimilar dielectric properties; the typical

value Dielectric Constant (εr) for oil is between 1.7 and 2.3 depending on the API gravity, and water has a typical value of 80.

i.e. Water is capable of storing much more energy per volume unit then average oil, which can be measured in pF.

Therefore, any change in the dielectric properties to oil due to water, will show up as a change in water content.

EASZ-1 is designed to measure such capacitance change, which is correlated to the change of water content, and output to a remote display, flow computer or data system.

• Oil & Water have dissimilar dielectric properties; the typical value Dielectric Constant (εr) for oil is between 1.7 and 2.3 depending on the API gravity, and water has a typical value of 80.

i.e. Water is capable of storing much more energy per volume unit then average oil, which can be measured in pF.

Therefore, any change in the dielectric properties to oil due to water, will show up as a change in water content.

EASZ-1 is designed to measure such capacitance change, which is correlated to the change of water content, and output to a remote display, flow computer or data system.

FORMS OF WATER CONTAMINATION

• DISSOLVED WATER.

• EMULSIFIED WATER.

• FREE WATER

WATER IN OIL MONITOR EASZ-1

• RANGE 0-25%• RESOLUTION 35 PPM• RESPONSE TIME: 1 SECOND• LOOP POWERED 2 WIRE• EX PROOF OPTIONAL• WORKS ON ALL TYPE OF OIL

Applicable to All OilApplicable to All Oil

Crude OilCrude Oil

Hydraulic OilHydraulic Oil

Lubrication OilLubrication Oil

Fuel OilFuel Oil

Vegetable OilVegetable Oil

ApplicationsApplications

Oil Rig

Tanker

Storage

Refinery

Food ManufacturingFood Manufacturing

Engine Lubrication SystemEngine Lubrication System

Oil Receiving QC

Paper Mill

EASZ-1 Water-in-Oil Monitor(for Palm Oil)

• Palm Oil Refineries – Unloading• Palm Oil Refineries – Process Control • Analyzer vs Monitor• Sample Conditioning• Water Separation & Emulsion• Purpose of Monitoring• EASZ-1 – applications

[space bar]

Unloading Process

IMPERFECT CONDITION

Inconsistent temperatureInconsistent propertiesInconsistent flow rate

IMPERFECT CONDITION

Inconsistent temperatureInconsistent propertiesInconsistent flow rate

THE PRACTICE…

BEFORE UNLOADING: Sample is taken from the top of the tanker.One at the top and another at the bottom.

DURING UNLOADINGSome, from the outlet.

[space bar]

EASZ-1 APPLICATION…

[space bar]

0.1250.1520.197

[space bar]

A L A R M0.1250 V R N

EASZ-1 APPLICATION…

The EASZ-1 is also suitable in some areas of process control e.g where the CPO moisture content needs constant monitoring before transferring to process line/storage; or for negotiation purposes.We can expect greater accuracy under these conditions mainly due to stable temperature and the fact that we are only looking at dissolved water in oil.

WA

TER

%

DATA LOGGER/RECORDER

Quick Start, Calibration & Maintenance

0.127

EASY CALIBRATION and “ZERO” point settingNo complicating external software required

Quick Start, Calibration & Maintenance

0.127

All ProgramAccessoriesCommunicationHyper Terminal

Quick Start, Calibration & Maintenance

TYPICAL INSTALLATION

Using Du series we can monitor Graph and record the Same

Specification & FunctionSpecification & FunctionSize

Water in Oil range

ResolutionTemperature compensationSensor Maximum Temperature rangeMinimum recommended flow velocityShipping WeightConstruction MaterialStandard Pressure RatingPower RequirementsElectronic Housing ProtectionElectronic Housing Temperature RangeHazardous Area ComplianceOutputsDisplay Options

1 inch Threaded -NPT or BSP / Flanged ANSI , DIN or JIS0- 0.1% (0-1000 ppm) , 0-1%, 0-3% , 0-10% ,0-25% (Jumper selectable)+/- 30ppmIntegral0-260 degF /125 degCRecommend 0.15 m/sApproximately 2kg/6lbsAll 316 stainless steel.16 Bar /230 psi (higher pressure consult factory)

Loop Power 12/24 vdcIP 66Range -40 °F -185 °F (-40 °C to 85 °C)(optional ATEX /IECEx Zone 0)4-20 mA DC , RS232 Full DuplexRemote readout/display /low-high alarm

Response time of 1 second

Loop power – 2 wire

Temperature Compensation

Flexible range

Easy Installation

Maintenance Free

Measurement of total water in any form whether dissolved, free or emulsified

FEATURES

ENGINES

• DIESEL OR FUEL INLET• ENGINE LUBRICATION.• INSTALLATION AFTER

CENTRIFUGE

Unloading Water-in-Oil Monitor

Unloading Water-in-Oil Monitor

USING WATER IN OIL Monitor FOR EMULSION Where We can Use Water In

oil Monitor For EMULSION

PUMP– Gear Pump, 5-6 kg pressure, Capacity -10-15 time of Emulsion volume per hour

Suggested Ratio

Making Emulsion

FO(49) : Water(49) : Solvent (2)

Mixing Emulsion

F.O (88-90) : EMULSION (10-12) EMULSIONMAKING

TANK

MAINSTORAGE

TANKFOR

MIXING &

PUMP TO BURNER / BOILER / FURNACE DIRECTLYTHROUGH DAY TANK

RETURN LINEEmulsion solvent

WATER LINE

FOR TANKER UNLOAD

P

V3

V5

V2

V1

V6 V4Duplex Filter

80-200 mesh

APPLICATION LUBE OIL

• FUEL INLET• MAIN ENGINE

LUBRICATION OIL.• HYDRAULIC UITS• STERN TUBE BEARING

LUBRICATION

EASZ1 RETROFITTED TO ALFALAVAL PURIFICATION SYSTEM

POWER PLANT-TURBINES

INSTALLATION IN A TURBINE LUB OIL SYSTEM

WATER IN OIL SYSTEM-Lube Oil at VRM and Raw Mill

EESIFLO International Pte Ltd