General features: what does DOCWin 2.1 calculate

Working with DOCWin 2.1: the ideal working sequence

Installation: system requirements and installation procedure

Learning: instruments to learn DOCWin 2.1

Assistance: how to contact ABB SACE

© A

BB S

ACE

-3

General features

What does DOCWin 2.1 calculate

© A

BB S

ACE

-4

Network without limitationsGeneral features

Unlimited number of nodes

MV/LV networks

Radial and meshed networks

Several distribution systems

© A

BB S

ACE

-5

Load-flowGeneral features

It’s possible to size all objects according to the the power of the transformer or (without flag) according to the load

© A

BB S

ACE

-6

ConfigurationsGeneral features

You can create different configuration in one single projectsBreakers can be set ON and OFF in each configuration….

Calculations can be done in actual configuration or in all...

© A

BB S

ACE

-7

Configuration creationGeneral features

Unlimited number of possible configurationsManual switch between configurations

© A

BB S

ACE

-8

Load-flowGeneral features

It’s also possible to consider loads at constant current: a way much closer to designer habits

© A

BB S

ACE

-9

Load-flow

In case of single phase-loads, DOC can select phase in order to optimize phase balancing

Automatic phase balancing

General features

© A

BB S

ACE

-10

Power factor correctionGeneral features

When sizing Utilities and busbars it’s possible to calculate thecapacitor power

© A

BB S

ACE

-11

Network calculationsGeneral features

Load-flow: voltage and load current in every point of the networkShort circuit: maximum and minimum Ik in every point of the network

© A

BB S

ACE

-12

Automatic dimensioningGeneral features

Protection relation

Co-ordination relations

Transformers

CablesBusway trunking systems

Switchgear and protection devicesCircuit breakersFusesSwitch disconnectorsResidual current circuit breakers

© A

BB S

ACE

-13

User friendlyGeneral features

Checking and warning of the faulty situations(to avoid to search for the problems already known by the program)

Electrical machines database(to have all the parameters of generators, motors and trafos)

Prototypes and blocks saving(to avoid to redo the same job)

Dimensioning / choice of one object only(like the old DOC )

© A

BB S

ACE

-14

Complete documentationGeneral features

All the data are printable in DOCWin 2.1 native formatSingle-line diagram with customized labels - customizablesReport of each single object - customizablesCurves diagrams and settings

All the data are exportable in the most common data exchange formats

Export of single-line diagram in DWG/DXF formatExport of reports in RTF and PDFformatExport of curves in WMF format

© A

BB S

ACE

-15

Working with DOCWin 2.1

The ideal working sequence

© A

BB S

ACE

-16

ABB solution for electrical plantsWorking withDOCWin 2.1

CAD Program

Network calculations

( SC, Load-Flow )

Network drawing

Sizing of cables, busways,

transformers

Protective devicesselection

Database ABB

Non competitorsDatabase (Zucchini)

User database

Codes list

Project

© A

BB S

ACE

-17

Single-line diagrams drawing

It is enough to select the object within the toolbar and position it in the diagram

Single-line diagram drawing

Working withDOCWin 2.1

© A

BB S

ACE

-18

Working withDOCWin 2.1 Power supply

Single-line diagram drawingSupplyGeneratorTwo windings transformerThree windings transformer

© A

BB S

ACE

-19

Working withDOCWin 2.1 Objetcs

Single-line diagram drawingImpedanceCableBusway

Busbar

© A

BB S

ACE

-20

Working withDOCWin 2.1 LV cable

Special window...Cable selectionMethod of installation

© A

BB S

ACE

-21

Working withDOCWin 2.1 LV cable (advanced settings)

It’s possible to modify R and X when you know they’re different form the default onesIt’s possible to enalble only some selected cross sections

© A

BB S

ACE

-22

Working withDOCWin 2.1 Protection devices

Single-line diagram drawingCircuit-breakerResidual current circuit - breakerFuse

© A

BB S

ACE

-23

Working withDOCWin 2.1 Circuit breakers

Filtered or free selectionCo-ordinationProtectionPre-definition of:

TypeExecutionReleaseIdn

© A

BB S

ACE

-24

Working withDOCWin 2.1 Single-line diagrams drawing

Single-line diagram drawingSwitch disconnectorContactor

© A

BB S

ACE

-25

Working withDOCWin 2.1 Single-line diagrams drawing

Single-line diagram drawingGeneric loadMotorLight loadMultibranch cableDistribution buswayPower factor correction group

-L1

© A

BB S

ACE

-26

Working withDOCWin 2.1 Generic load

All necessary informations are in the same windowAll possibilities:-by apparent power and pf-by active/reactive power-by current and pf-by active power and pf

© A

BB S

ACE

-27

Working withDOCWin 2.1 Motors

Single-line diagram drawing

Motor

© A

BB S

ACE

-28

Working withDOCWin 2.1 Motors

MotorABB motors database

(from 0.18 to 710 kW )

Single-line diagram drawing

© A

BB S

ACE

-29

Working withDOCWin 2.1 Motors

MotorStarter co-ordination and protection

Single-line diagram drawing

© A

BB S

ACE

-30

Working withDOCWin 2.1 Motors

Different symbols for relevant type of protection

© A

BB S

ACE

-31

Working withDOCWin 2.1 Light load

You can define:Lamp type/technologyPowerNumber of lampsDistances

Doc sizes the cable

© A

BB S

ACE

-32

Working withDOCWin 2.1 Multimeter

All network calculations available in every point of the installation

© A

BB S

ACE

-33

Working withDOCWin 2.1 Single-line diagrams drawing

Single-line diagram drawingConnectionLine departureLine arrival

© A

BB S

ACE

-34

Working withDOCWin 2.1 Data input

DOCWin 2.1 helps the user during the data input ...

Single-line diagram drawing

Data input

... showing the default values stored in the prototype

... with the databases of the electrical machines

... with a customized dialog window for each object

... by asking for the missing data during the automatic dimensioning

© A

BB S

ACE

-35

Working withDOCWin 2.1 Network congruity

DOCWin 2.1 verifies the congruity of the network and signals every anomalous situation

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

© A

BB S

ACE

-36

Working withDOCWin 2.1 Load - Flow

DOCWin 2.1 calculates the load current for each object and the voltage level at each node using the Newton-Raphson method

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

© A

BB S

ACE

-37

Working withDOCWin 2.1 Cable sizing

DOCWin 2.1 sizes and checks the cables in compliance with the following Standards:

IEC 60364-5-23VDE 298-4NFC 15-100CEI 64-8

IEC 60890 (PTTA switchboards)

IEC 60092 (for ship)

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

Cables, busways,trafos sizing

© A

BB S

ACE

-38

Working withDOCWin 2.1 Short-circuit

DOCWin 2.1 calculates the maximum and minimum short-circuit currents for LLL, LL, LN, L-PE in compliance with:

IEC 60909-1

IEC 61363-1 (for ship)

Symmetrical component method

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

Cables, busways,trafos sizing

Short-circuit

© A

BB S

ACE

-39

Working withDOCWin 2.1 Devices selection

DOCWin selects circuit-breakers and fuses taking in account the protection of cables, busways, switch disconnectors and residual current circuit breakers

Note:

Restrictions do not alwaysallow a solution !

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

Cables, busways,trafos sizing

Short-circuit

Devices selection

- Long discrimination or back-up chains- Protection against indirect contacts with wrong function- Ib too close to Iz of the protected cable- wrong Standard selection- ...

© A

BB S

ACE

-40

Working withDOCWin 2.1 Devices selection

DOCWin selects circuit-breakers taking in account discrimination and back-up relations between breakers

Note:

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

Cables, busways,trafos sizing

Short-circuit

Devices selection Tables used by DOCWin are valid up to 436VComputation time is function of the number of linked breakers and growths like a factorial funtion

© A

BB S

ACE

-41

Working withDOCWin 2.1 Manual refinement

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

Cables, busways,trafos sizing

Short-circuit

Devices selection

Manual refinement

The user shall check the solution proposed by DOCWin 2.1 to optimize it.In particular, the user can ...

... Select manually the objects

... Oversize the cables and the busways

... Select the tapping of the transformers

... Lock the manually choosen objects

... Set the relays

© A

BB S

ACE

-42

Working withDOCWin 2.1 Drawing curves

Time-current curvesSpecific let-through energy curvesLimitation curves

0.1kA 1kA 10kA

1E-2s

0.1s

1s

10s

100s

1E3s

1E4s

Curva Tempo-Corrente LLL

0.1kA 1kA 10kA 100kA

0.1MA²s

1MA²s

10MA²s

100MA²s

1E3MA²s

1E4MA²s

Curva Energia specifica passante LLL

10kA 100kA

10kA

100kA

1E3kA

Curva Picco

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

Cables, busways,trafos sizing

Short-circuit

Devices selection

Manual refinement

Drawing curves

© A

BB S

ACE

-43

Working withDOCWin 2.1 Documentation printouts

Single-line diagramReportCurvesSettings

0.1kA 1kA 10kA

1E-2s

0.1s

1s

10s

100s

1E3s

1E4s

Curva Tempo-Corrente FFF

Reference voltage=400 VElectronic rele: -QF1 S6X 400 PR212-LSI R400L : Setting: 0.67 Curva: 18S I²t=cost Setting: 9.5 Curva: 0.35I Setting: 12

TM Rele: -QF2 T3N 250 R250LT: Setting: 212.499 [A]

Preload: 202.272 [A]INST: Setting: 2500 [A]

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

Cables, busways,trafos sizing

Short-circuit

Devices selection

Manual refinement

Drawing curves

Documentation printouts

© A

BB S

ACE

-44

Working withDOCWin 2.1 Data export

DOCWin 2.1 can export data of ABB SACE products ...

... to CATs for the selection of the accessories

... to DMB for the switchboard configuration, for the budgedting or for the detailed drawing of the single-line diagram

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

Cables, busways,trafos sizing

Short-circuit

Devices selection

Manual refinement

Drawing curves

Documentation printouts

Data export

© A

BB S

ACE

-45

Working withDOCWin 2.1 Data export

Aut

omat

ic d

imen

sion

ing

Single-line diagram drawing

Data input

Network congruity

Load- Flow

Cables, busways,trafos sizing

Short-circuit

Devices selection

Manual refinement

Drawing curves

Documentation printoutsData export

© A

BB S

ACE

-46

Instruments to learn DOCWin 2.1

Learning

© A

BB S

ACE

-47

User manualLearning

© A

BB S

ACE

-48

Video courseLearning

Italian orenglish only !

© A

BB S

ACE

-49

Installation

System requirements and installation procedure

© A

BB S

ACE

-50

System requirementsInstallation

OS from Win‘95 to Win2000

Unlimited number of installations

Administrator privileges required

At least 60 Mb of hard disk space

Be sure no other application (anti-virus program) are running during the installation !!!!!

© A

BB S

ACE

-51

Installation procedureInstallation

Double-click Start.exe

© A

BB S

ACE

-52

Assistance

How to contact ABB SACE

© A

BB S

ACE

-53

Call centerAssistance

claudio.brazzola@it.abb.comclaudio.bizzo@it.abb.comE-mail is the best way to communicateefficiently with the working group

Precise explanations of the problem and an example file attached to the e-mail help us to solve the problem

© A

BB S

ACE

-54

http:\\bol.it.abb.comAssistance

to ask for a free version of the program

to be informed about the news

http:\\bol.it.abb.comNow avalaible

the english version

© A

BB S

ACE

-55

top related