control of ion energy distributions on plasma...

Post on 24-Jul-2020

1 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

P. Diomede, D. J. Economou and V. M. DonnellyPlasma Processing Laboratory, University of Houston

Control of Ion Energy Distributions on Plasma Electrodes

1

DOE Plasma Science Center Teleseminar, February 8, 2013

Outline

• Introduction/Motivation

• 3 Methods to control IEDs on plasma electrodes

• PIC‐MCC simulations and comparisons with experiments

• Model for rapid calculation of IED and comparisons with experiments

• Conclusions

2

Introduction / Motivation

• Control of the energy of ions bombarding a substrate is important for both plasma etching and PECVD. 

• The ion energy must be high enough to drive anisotropic etching, but not too high to induce substrate damage and/or loss of selectivity.

• As device dimensions keep shrinking, requirements on selectivity and substrate damage become ever more stringent. 

• In addition, the ion bombardment energy is critical for controlling film microstructure and properties in PECVD.

• Such requirements impose strict limits not only on the mean ion energy but also on the ion energy distribution (IED). 

3

1 232 2

/i

rf s

s M( )eV

τ ωτ π

=

τi/τrf <<1  wide (bimodal) IED

τi/τrf >>1  narrow (single peaked) IED

IED on an electrode biased with sinusoidal RF voltage

τi = ion transit time through sheathτrf = period of the rf sheath E‐field =2π/ω

4

IED for Sinusoidal Sheath Voltage

IEDs on the grounded electrode of a 13.56 MHz Ar CCP at 75 mTorr. Peak separation is reduced for heavier ions. Single peak is centered at the DC sheath voltage. Impurity ions are used to avoid charge transfer collisions.1

IEDs on the grounded electrode of an Ar CCP at 50 mTorr. A singlepeak is obtained at high enough frequencies.2

1. J. Coburn and E. Kay, J. Appl. Phys., 43, 4965 (1972).2. K. Kohler et al., J. Appl. Phys., 58, 3350 (1985).

5

1. Plasma is generated by independent source power. Apply judicious bias voltage waveform on the substrate electrode immersed in the plasma. 

M. A. Wank, R. A. C. M. M. van Swaaij, P. Kudlacek, M. C. M. van de Sanden, and M. Zeman, J. Appl. Phys. 108, 103304 (2010)

Three principal ways to control IEDs

The voltage appearing on the face of the substrate is at a constant negative value (Vfront), except for small excursions to positive values to neutralize the charge.

6

The substrate bias has minor effects on the plasma chemistry.

The energy of ions is determined by the substrate voltage.

A. Agarwal and M. J. Kushner, J. Vac. Sci. Technol. A 23, 1440 (2005)

This voltage waveform on the substrate is positive during α=10% of the cycle.

Effect of non‐sinusoidal bias waveforms on IEDs

Computational investigation by Agarwal and Kushner using an ICP reactor scale model.

15 mTorr Ar/c‐C4F8=75/25 gas mixture.500 MHz TVW frequency

7

Three principal ways to control IEDs

• The Electrical Asymmetry Effect (EAE) provides a new method to control the  ion energy distribution (IED) on plasma electrodes. Importantly, the ion flux can also be controlled, independently of the ion energy.

• A voltage of the form                                           

is  applied  to  an  electrode  of  a  capacitively‐coupled  plasma  (CCP)  reactor, with f2=2f1.   The DC bias  (thus  the  ion energy) can be varied simply by changing  the phase θ1.

• Adding  higher  harmonics  enhances  the  EAE,  but  implementation  becomes cumbersome.

• A  DC  bias  can  be  imposed  even  on  a  geometrically  symmetric  system  (equal electrode areas).

)2cos()2cos()( 22111 tfUtfUtV πθπ ++=

2.  Produce the plasma with customized voltage waveforms.

The Electrical Asymmetry Effect

8

Measured  ion  energy  distribution  functions  in  a  geometrically  and  electrically  asymmetric discharge at the powered (left) and grounded (right) electrode (Argon, 1 Pa, d = 4 cm, U1 = U2 = 100 V, f1 = 13.56 MHz, f2 = 27.12 MHz).

)2cos()2cos()( 22111 tfUtfUtV πθπ ++=

9

Control of ion energy distributions using the electrical asymmetry effect

U. Czarnetzki, J. Schulze, E. Schüngel and Z. Donkó, PSST, 20, 024010 (2011)

Mean ion energy and ion flux as a function of θ1 in an argon CCP discharge. 7.5 mTorr, U1=U2=100 V, f1=13.56, f2= 2f1.

)2cos()2cos()( 22111 tfUtfUtV πθπ ++=

Independent Control of Ion Flux and Ion Energy

As the phase shift θ1 is varied, ion energy varies but ion flux remains almost constant.

U. Czarnetzki, J. Schulze, E. Schüngel and Z. Donkó, PSST, 20, 024010 (2011)10

Gaussian voltage pulses (repetition frequency of 13.56 MHz) of the form

V0 = voltage amplitudet0  = time of pulse max, ∆τ = FWHM  

20 0V( t ) V exp[ a( t t ) ]= − −

2 2ln / a∆τ =

T. Lafleur and J. P. Booth, J. Phys. D: Appl. Phys., 45, 395203 (2012)

Gaussian Voltage Pulses

11

IED depends on FWHM (∆τ) of applied voltage

Three principal ways to control IEDs 3. Apply synchronous bias on boundary electrode during 

afterglow of pulsed plasma 

Boundary Voltage

Plasma

Boundary Electrode

Substrate

Plasma Power

Bias ON

ON OFF

For a grounded  conductive substrate, the sheath voltage is equal to the plasma potential.

12

0 10 20 30 40 50 60 70 80 90 1000.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0 OFFON

T e(eV)

time (µs)0 10 20 30 40 50 60 70 80 90 100

0

2

4

6

8

10

12

14

16

V p(V)

time (µs)

Time‐resolved Langmuir probe measurements

13

• Te is hardly affected by the application of the DC bias, while Vp is raised.• The spread in the energy of ions entering the sheath scales with Te.1

13

1.   K.‐U. Riemann, Phys. Fluids 24 2163 (1981)

Te and Vp during a pulse

0 4 8 12 16 20 24 28 320.00

0.01

0.02

0.03

0.04

0.05

Tim

e-A

vera

ged

Ion

Ene

rgy

Dis

tribu

tion

Energy (eV)

Ar press. (mTorr): 7 14 50 28

IEDs in pulsed Ar ICP with synchronous DC bias voltage applied to the boundary electrode

Separation of the peaks can be tuned by DC bias value and pressure.

Narrow IED can be achieved in the afterglow.

Full width at half maximum (FWHM) of the IED ranges from 1.7 to 2.4 eV.

14H. Shin, W. Zhu, L. Xu, D. J. Economou and V. M. Donnelly, PSST, 20 055001 (2011). 

15

IEDs in pulsed Ar ICP with different synchronous DC bias voltages applied to the boundary electrode

M. D. Logue, H. Shin, W. Zhu, L. Xu, V. M. Donnelly, D. J. Economou and M. J. Kushner,  PSST, 21 065009 (2012) 

• DC Bias applied continuously on the BE.• Peak at high energy is shifted by the energy 

of the applied dc bias for positive biases.• Low energy peak not detected by the 

measurements which discriminate low‐energy ions having a broad angular distribution.

PIC‐MCC Simulations

• Simulation of pulsed plasma with synchronous boundary voltage.

• Comparison with experimental data.

16

Simulation of Pulsed CCP Reactor with DC Bias in Afterglow

• Pulsed plasma is sustained in capacitively coupled plasma (CCP) reactor.• 50 V DC bias is applied on the upper (boundary) electrode in the afterglow to modify the IED on the lower (substrate) electrode. 

17

Application of DC Bias in the Afterglow of a Pulsed Plasma

• After plasma power turn off (afterglow), Te and Vp decay rapidly.• Apply synchronously tailored positive bias voltage Vdc during specified time window in the afterglow.• Bias raises plasma potential, modifying the IED on the wafer.

18

0 50 100 150 2000.0

0.2

0.4

0.6

0.8

1.0

1.2

Nor

mal

ized

IED

Ion energy (eV)0 50 100 150 200

0.0

0.2

0.4

0.6

0.8

1.0

1.2

Nor

mal

ized

IED

Ion energy (eV)

PIC simulation of Ar CCP: IED without Bias

IED for continuous wave (cw) plasma w/o bias

IED  for pulsed plasma(10 kHz, 50% duty cycle) w/o bias

Ar plasma, VRF = 300 V, νRF = 13.56 MHz, p = 10 mTorr, d = 6 cm10 kHz pulse frequency  50% duty ratio

• Bimodal IED is retained, originating from the power ON fraction of the cycle• New peak appears at very low energies due to ions bombarding the substrate during the afterglow. 

• Bimodal distribution centered around 1/2 VRF. • Tail to the left of the main peak due to ion‐neutral collisions. • Multiple secondary peaks given by ions created by CE collisions.  19

IEDs with Staircase DC Bias Applied in Afterglow

• Afterglow starts at time t = 50 µs.• Additional peaks appear in the IED.• Peak location can be controlled by the value of the applied bias voltage.

20

IEDs with Staircase DC Bias Applied in Afterglow (2)

Peak strength can be controlled by the duration of the respective DC bias voltage.The relative strength of the other two peaks can be controlled by the duty ratio.

P. Diomede, V. M. Donnelly and D. J. Economou, J. Appl. Phys., 109, 083302 (2011) 21

0 10 20 30 40 50 60 70 80 90 1000

1

2

3

n e (10

15m

-3)

Time (µs)

EEPF and Electron Density Evolution

• In the afterglow of pulsed CCP, apply 50 V DC during t = 70‐85 µs, followed by 300 V DC during t = 85‐100 µs.• EEPF is temporarily heated when the bias is applied but the electron density evolution is hardly affected. 22

30 40 50 60 70 80 90 1000.0

0.5

1.0

1.5

2.0

2.5

3.0

Time (µs)

T e (eV

)

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 320.00

0.01

0.02

0.03

IED

F

∆t = 38 µs

∆t = 28 µs

∆t = 18 µs

∆t = 48 µs

Energy (eV)

50-98µs 60-98µs 70-98µs 80-98µs

Comparison of PIC Simulation with Experimental Data

IEDs predicted by the PIC simulation of the afterglow (right) compared to data# (left). The low energy peak of the data is due to the active glow (not simulated by PIC).   

Electron temperature in the afterglow predicted by PIC (line),compared to data# (points). 

Pulsed Ar plasma, 10 KHz modulation, 20% duty, 14 mTorr, 120 W average power, 24.4 V DC bias applied in afterglow during time windows shown above.

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 320.0

4.0x1010

8.0x1010

1.2x1011

1.6x1011

2.0x1011

2.4x1011

2.8x1011

3.2x1011

3.6x1011

4.0x1011

4.4x1011

Ion

flux

(a.u

.)

Energy (eV)

simulation

# H. Shin, W. Zhu, L. Xu, D. J. Economou and V. M. Donnelly, PSST, 20 055001 (2011).  23

Simulation of Pulsed H2 CCP Reactor with DC Bias in Afterglow

24

The Bari hybrid model for H2 CCPs

Neutral species: fluid model for H atoms and H2(v = 0,…14).Plasma  kinetics:  PIC/MCC  applied  to  electrons  and  four  ionic species (H3

+, H2+, H+, H‐). 

Application of DC Bias in the Afterglow of a Pulsed Plasma

• After plasma power turn off (afterglow), Te and Vp decay rapidly.• Apply synchronously tailored positive bias voltage Vdc during specified time window in the afterglow.• Bias raises plasma potential, modifying the IED on the wafer.

25

0 10 20 30 40 50 60 70 80 90 1000

1

2

3

4

5

6

time (µs)

Ele

ctro

n K

E (e

V)

Number densities and electron KE Evolution

0 10 20 30 40 50 60 70 80 90 1000.0

2.0x1014

4.0x1014

6.0x1014

8.0x1014

1.0x1015

1.2x1015

num

ber d

ensi

ty (m

-3)

time (µs)

H+

H+2

H-

e-

H+3

RF ON RF OFF DC ON

• Plasma ON  (t=0 µs):  increase approaching quasi‐steady‐state values ~ 20 µs. • Plasma OFF  (t=50  µs):  decay    throughout the afterglow .• H2

+ ions  disappear  after  5  µs  into  the afterglow. 

mid‐plane of the discharge (x = 3 cm)

• Plasma ON (t=0 µs): rapidly rise to a peak early, quasi‐steady‐state ~ 10 µs. • Plasma OFF (t=50 µs): plummet during the first few µs and decay at a much slower rate later in the afterglow.• DC bias ON (t=70 µs): temporary heating.

26

Hydrogen plasmaVRF = 300 V, νRF = 13.56 MHz, p = 50 mTorrd = 6 cm, 10 kHz pulse, 50% duty ratio

0 50 100 1500.0

0.2

0.4

0.6

0.8

1.0

Nor

mal

ized

IED

Ion energy (eV)0 50 100 150

0.0

0.2

0.4

0.6

0.8

1.0N

orm

aliz

ed IE

D

Ion energy (eV)

H+3

experiment

Experiments: D. O’Connell et al. Phys. Plasmas 14, 103510 (2007)

IEDs for continuous wave (cw) plasma w/o bias (1)

simulation simulation

H2, VRF = 300 V, νRF = 13.56 MHz, 50 mTorr, 6 cm

H3+

H+

• Bimodal structure and tail towards lower energies due to ion‐neutral collisions. • The H+ IED bimodal structure has a wider energy spread, due to the lower mass of H+.• Predicted bimodal distribution, with a more intense peak at lower energy, is close to the experimental IED for H3

+.

27

IEDs for continuous wave (cw) plasma w/o bias (2)

0 50 100 1500.0

0.2

0.4

0.6

0.8

1.0

Nor

mal

ized

IED

Ion energy (eV)

Experiments: D. O’Connell et al. Phys. Plasmas 14, 103510 (2007)

experiment

simulation

H2, VRF = 300 V, νRF = 13.56 MHz, 50 mTorr, 6 cm

H2+

H2+

• H2+ IED exhibits multiple peaks, 

explained by symmetric charge exchange collisions during the sheath collapse.• Ions thus created experience only a fraction of amplitude of the oscillating sheath voltage. • Computed H2

+ IED is in good agreement with experimental results.• The energy dependence of the acceptance angle of the ion optics contributes to an artificial distortion of the IED in the low energy region.

28

Computed IEDs for pulsed plasma with 50 V DC bias in the afterglow

0 50 100 1500.0

0.2

0.4

0.6

0.8

1.0

Nor

mal

ized

IED

Ion energy (eV)

H+3

0 50 100 1500.0

0.2

0.4

0.6

0.8

1.0

H+2

Nor

mal

ized

IED

Ion energy (eV)

0 50 100 1500.0

0.2

0.4

0.6

0.8

1.0H+

Nor

mal

ized

IED

Ion energy (eV)

• Additional  peaks  appear  in  the H3+

and H+ IEDs.• Peak  location  can  be  controlled  by the value of the applied bias voltage.• H2

+ disappear  in  the  afterglow due to the rapid decay of Te.

H2, VRF = 300 V, νRF = 13.56 MHz, 50 mTorr,  6 cm10 kHz pulse, 50% duty ratio

29

Blocking capacitor, Cb

Applied rf, Vrf

Bulk Plasma (n0, Te)

Electrode (Target)

Sheath

Assumptions: Bulk n0 and Te are not influenced by rf bias. Sheath is collisionless.    Ion flux at sheath edge is time‐independent. 

Model for Rapid Calculation of IEDon Electrode in Contact with Plasma

30

Semi-analytic Model

Schematic of the sheath region 1. Electrode immersed in semi‐infinite plasma of given electron (ion) density and electron temperature.

2. Electron, ion and displacement currents flow through the sheath.

3. Non‐linear sheath capacitance Cs is calculated from the electric field at the electrode, E.

1 21 1

0 1

2 2 /e s s

e

n kT e(V V ) VE [exp( ) ]kT Vε

−= − + −

0ss

EC AV

ε ∂= −

A. Metze, D. W. Ernie, H. J. Oskam, J. Appl. Phys., 60, 3081 (1986).P. Miller and M. Riley, J. Appl. Phys., 82, 3689 (1997).T. Panagopoulos and D. Economou, J. Appl. Phys., 85, 3435 (1999).

V=VS V=V1 V=0

Id

Ie

Ii

Electrode Sheath Pre-sheath Plasma (bulk)

xn0, Te

31

Equivalent Circuit Model

0

0

b rf T T P T T

T P T G P T G

d dC (V V ) C (V V ) Idt dtd dC (V V ) C V I Idt dt

− + − + =

− + + + =

Voltage Vrf is applied through blocking capacitor, Cb. Given n0, Te, Vrf and Cb, calculate VT , Vp, and Vd.

Ions respond toa “damped” potential Vd

Subscripts T and G refer to “target” and “ground” electrodes, respectively.

i

pTdd VVVdt

dVτ

)( −−−=

IG

IT

VP

CG

CT

VTCbVrf

A. Metze et al., J. Appl. Phys., 60, 3081 (1986).

32

# of points in 0< 2 such that

( )

1 1( )2

( )( )

( ) " "

d

t d

V t y

d d

f ydV

d tf y IED

V V t damped sheath voltage

ω π

ω

πω

ω

<

=

=

== =

1

# of points in 0< 2 such that ( )

( )1( )2

d

d

tV t y

dV yf ydyω π

ωπ

<=

= ∑1( ) ( )d dy V t t V yω ω −= ⇒ =

P. Diomede, M. Nikolaou, D. J. Economou, Plasma Sources Sci. Technol., 20, 045011 (2011). E. Kawamura, V. Vahedi, M.A. Lieberman, C.K. Birdsall, Plasma Sources Sci. Technol., 8, R45 (1999).

Ion Energy Distribution

Sample damped sheath potential waveform

yy+dy

ωt0Vd(ωt)

2ππ0

dy

Support (y,y+dy)

y = ion energy

33

0 20 40 60 80 1000

5

10

15

20

Vp (V

)

Time (µs)

0 5 10 15 20 25 300.0

0.2

0.4

0.6

0.8

1.0

1.2

Nor

mal

ized

IED

Ion energy (eV)0 5 10 15 20 25 30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

Nor

mal

ized

IED

Ion energy (eV)

Comparison of Semi‐analytic Model with Experimental Data (1):Pulsed Argon Plasma with DC bias in the afterglow

IEDs predicted by the semi‐analytic model (right) compared to data# (left).  

Plasma potential w/o DC bias predicted by the semi‐analytic model (line), compared to data#

(points). 

Pulsed Ar plasma, 10 KHz modulation, 20% duty, 14 mTorr, 120 W average power, 24.4 V DC bias applied in afterglow during ∆tb = 45‐95 µs.

# H. Shin, W. Zhu, L. Xu, D. J. Economou and V. M. Donnelly, PSST, 20 055001 (2011). 

modelexperiment

34

Experimental Target voltage, 500 kHz, ne = 2.6×1016 m‐3, Te = 3eVX. V. Qin, Y.‐H. Ting, and A. E. Wendt, PSST 19 065014 (2010).

-300

-200

-100

0 (b)

-300

-200

-100

0 (c)

0 1 2 3 4 5

-300

-200

-100

0 (d)

Time (µs)

Volta

ge (V

)

-300

-200

-100

0 (a)

Target voltage in the semi‐analytic model

The simulated voltage waveforms are quite representative of the measured waveforms except for the “ringing”.

Comparison of Semi‐analytic Model with Experimental Data (2):Helicon plasma with bias voltage waveform on the substrate

35

Experimental Ar+ IEDs X. V. Qin, Y.‐H. Ting, and A. E. Wendt, PSST 19 065014 (2010).

0 100 200 300 4000.00.20.40.60.81.0

Ion energy (eV)

(d)

0.00.20.40.60.81.0

(a)

0.00.20.40.60.81.0

(b)

0.00.20.40.60.81.0

(c)

Nor

mal

ized

IED

IEDs from the semi‐analytic model

• Predicted peak locations and heights of the IED are in agreement with the measurements. • The FWHM of the experimental peaks is larger, because of the ringing of the applied voltage waveforms.

Comparison of Semi‐analytic Model with Experimental Data (2):Helicon plasma with bias voltage waveform on the substrate

36

M. A. Wank, R. A. C. M. M. van Swaaij, P. Kudlacek, M. C. M. van de Sanden, and M. Zeman, J. Appl. Phys. 108, 103304 (2010)

The voltage appearing on the face of the substrate is at a constant negative value (Vfront), except for small excursions to positive values to neutralize the charge.

37

The substrate bias has minor effects on the plasma chemistry.

The energy of ions is determined by the substrate voltage.

Comparison of Semi‐analytic Model with Experimental Data (3):ETP with bias voltage waveform on a dielectric substrate 

#P. Kudlacek, R. F. Rumphorst and  M.C.M. van de Sanden, J. Appl. Phys.,  106, 073303 (2009).

Comparison of Semi‐analytic Model with Experimental Data (3):ETP with bias voltage waveform on a dielectric substrate 

• Electrode downstream of expanding thermal hydrogen plasma (H3

+). • Biased through blocking capacitor, Cb = 166 pF.• Vp~0.2 V, Te = 0.15 eV, p = 18 Pa, ne = 2 x 1010 cm‐3

Top figs.: Kudlacek et al.#

Bottom figs.: Semi‐analytic model prediction.CB = 1.66 nF, AG/AT =25

• The energy peaks location and the voltage waveform on substrate electrode are predicted.

Voltage applied to blocking cap.

Voltage of substrate electrode.

38

Measured  ion  energy  distribution  functions  in  a  geometrically  and  electrically  asymmetric  dual  frequency  discharge  at  the  powered  (left)  and  grounded  (right) electrode (Argon, 1 Pa, d = 4 cm, U1 = U2 = 100 V, f1 = 13.56 MHz, f2 = 27.12 MHz).

)2cos()2cos()( 22111 tfUtfUtV πθπ ++=

Comparison of Semi‐analytic Model with Experimental Data (4):Control of IEDs using the electrical asymmetry effect

U. Czarnetzki, J. Schulze, E. Schüngel and Z. Donkó, PSST 20, 024010 (2011)39

0 20 40 60 80 100 120 140 160

0.00

0.02

0.04

0.06

0.08

015

3045

6075

90

powered electrode

Ion energy (eV)IE

D (a

.u.)

θ 1 (de

gree

s)

0 10 20 30 40 50

0.00

0.04

0.08

0.12

0.16

0.20

015

3045

6075

90

grounded electrode

Ion energy (eV)

IED

(a.u

.)

θ 1 (de

gree

s)

Cb = 0.7 pF, AG = 2 AT , Te = 3 eV, n0 = 2 x 1015 m‐3, M = 40 amu (Ar+), f1 = 13.56 MHz, f2 = 27.12 MHz, U1 = U2 = 100 V, instrumental broadening 2 eV.

Electrical Asymmetry Effect: Semi‐Analytic Model Prediction

40

Concluding Remarks

Several methodologies can be implemented to tailor the ion energy distribution on plasma electrodes.PIC‐MCC and hybrid simulations of a pulsed plasma with synchronous DC bias applied in the afterglow, showed that it is possible to tailor IEDs to have distinct energy peaks with controlled energies and fraction of ions under each peak.Simulations were in good agreement with measurements.Although PIC simulation provides detailed information (e.g., IADin addition to IED), fast execution of semi‐analytic model is advantageous for initial screening of tailored voltage waveforms. Models/simulations in synergy with experiments are critical to understand and predict the behavior of plasmas and to unravel new strategies for tailoring IEDs.

41

Prof. M. Nikolaou, University of HoustonDr. H. Shin, University of Houston, currently at Lam Research Corp.W. Zhu, University of Houston

Prof. S. Longo, University of Bari and CNR/IMIP, ItalyProf. M. Capitelli, University of Bari and CNR/IMIP, Italy

Financial Support: DoE Plasma Science Center NSF

Acknowledgements

42

top related