Design Features
- Easy, fast& accurate digital with 11 points calibration
- Laser sensor offering actual feed values
- Modern, improved, durable external design
- Convenient, quick, overall internal design
- Fully automatic control by the AUTOVALVE responding to external
signals in variety
- Safe& reliable all-vacuum operation
- Capacity ranges up to 10,000 PPD(200kg/hr)
- Linear feed rate by AUTOVALVE of Sonic Flow Design
- New gas filter system in vacuum line
AQUS Series CH4200 Floor Mounted chlorinators are vacuum operated,solution feed devices available either with manual control or with automatic control.
Vacuum Gas ChlorinatorSeries CH42001PPD to 10,000PPD(0.2kg/hr to 200kg/hr)Floor-Mounted Type
Power 115/230 VAC(± 15%), 50/60 Hz, Single Phase
Physical FLOW : 4~20mA DCVALVE POSITION : Potentionmeter input
Display 2-line, 16 characters, Back-lighted LCD
Calibration Factory Set & Field Adjustable0%~100% Valve 10(ten)-set Points4mA~20mA Input Signal4mA~20mA Output(valve Position)
Aiarm Contact 10Amps@120 VAC or 30 VDC5Amps@240 VAC resistive load, unlatching
Dosage Ratio 4:1 Adjustable through Keypad & display
Environment Limits 32 to 122℉(0 to 50℃)
Gas Injection(kg/hr)
PPD 10 25 50 100 200 500 1,000
kg/hr 0.2 0.5 1.0 2.0 5.0 10 20
PPD 1,500 2,000 3,000 4,000 6,000 8,000 10,000
kg/hr 30 40 60 80 120 160 200
Step Motor Bi-polar(4 wire), 5,6 VDC, 1A Phase Resistance5.6 ohms Phase Inducatance 25.6 mH HoldingTorque 72 oz-in Rotor Inertia 0.00166 oz-in-sec²
Valve Plug Travel 1.25” Maximum
Keyboard Inputs Dosage Ratio, Residual Set PointAlam Set Points, Manual Psition SetValve CalibrationOpen posit ions 4~20mA input, 4~20mA output, Calibration input Signal Filter(Adjust sensitivity to minor signal change)
Control Mode Manual and/or Automatic
Shipping Weight 65kg
Laser System(Option) Laser Sensor measuring Actual Float Level & Output 4~20mA
Accessory Vacuum Regulator, Ejector
Specifications
certified
Series CH42001PPD to 10,000PPD(0.2kg/hr to 200kg/hr)Floor-Mounted Type
Design Features
- Fully Automatic Control by Microprocessor-based Controller
- 1 Month Working Data Memory backing by Black box
- Easy Check of Working Condition by newly-improved Controller
- Vaporizer Chamber Fabrication exceeding ASME Code
- Standard Design of No Circulation Pump by a way of Convection
- New Design of Cathodic Protection System
- Simple Set of Control Values
Electrically-Heated EvaporatorSeries EV72006000PPD to 10,000PPD(120kg/hr to 200kg/hr)Floor-Mounted Type
Type Water Bath Type in Electrically Automatic Operation
Power 3Phase, 380 VAC, 50/60Hz
Control 115/230 VAC(±15%), 50/60Hz, Single Phase
Material Water tank : SB41 + GalvanizedPressure vessel : SPPS SCH #80
Standard Accessories Electric immersion heaterFiberglass cabinetPVC form insulationGalvanized water chamberGas pressure gauge(bar and MPa)Gas temperature gauge(℃ and ℉)Super-heated baffleVaporizing chamberWater level sight gaugeWater level control switchWater low level alarm switchElectronic cathodic protection system
Capacity & Service
ModelChlorine Sulfur Dioxide Ammonia Heater
capacitylb/day kg/hr lb/day kg/hr lb/day kg/hr
EV7212 6000 120 4500 85 1250 25 12kW
EV7215 8000 160 6000 115 1680 35 15kW
EV7218 10000 200 7500 140 2100 40 18kW
Standard Accessories Digital electronic temperature controller(Microprocessor based)-Water temperature controller-Water low temperature alarm switch-Water high temperature alarm switch-Water temperature display(1)Solenoid valve(1/2″ NPT)
Pressure Ratings Hydrostatic Test Pressure : 5.7 MPaDesign Pressure : 3.8 MPa at 100℃
Contacts PRV working, Low water temperature alarmHigh water temperature alarm, Low water level alarm
Electronic Digital controller
Microprocessor based, Water temperature controllerWater low temperature alarm switch,Water high temperature alarm switchWater temperature display, PRV control status
Data Memory(Black box function)
(1) Month working memory backing-up (Vaporizer temperature, Water level, Gas pressure, PRV working)
Shipping weight 408kg
Other Accessory PRV, Safety valve
Specifications
certified
Design Features
- Alarms in presence of target gas (Chlorine,
sulfur dioxide or others)
- Up to 4(four) sensors Input
- Field programmable alarms and range-settings
- Long-life sensor : 3 more years expected
- Alphanumeric display of gas concentration
- Simple, fast calibration in engineering units
- Integral audible and visual alarms
- 4-20 mA DC output and contact output
- Battery backup (optional)
Calibration
Field calibration of the GD100 is ultra-simple. A special program feature in the indicator allows the operator to perform field calibration from the operator keypad using only a simple voltmeter and a 4-20mA DC signal generator. Whether calibrating electrically or using a calibration gas, there is no need to open the instrument to accomplish the calibration work.
Gas MonitorSeries EV72006000PPD to 10,000PPD(120kg/hr to 200kg/hr)Floor-Mounted Type
Series GD100Electrochemical Type
Type Electrochemical
Enclosure NEMA 4X
Dimensions 4" wide x 4" high x 2" deep
Range 0.1 to 30.0 PPM Cl2 or SO2, field selectable
Temperature -20 to +50℃
Pressure Ambient +/- 10%
Power 12 VDC from alarm indicator unit
Sensor resolution* 0.1 PPM Cl20.5 PPM SO2
*Sensors availiable for other gases. Consult factory.
Enclosure NEMA 4X (IP65)
Dimensions 6.5" wide x 6.5" high x 5.5" deep
Analog Output Isolated 4-20 mA DC
Digital Output RS232, RS485 optional
Power Requirement 120/240 VAC, 50/60 Hz, single phase
Display 16-characters x 2-lines LCD, backlit
Alarms Three, Programmable
Alarm Contacts Gold, 1.2A@120 Vac
Memory Non-volatile EEPROM
Data & Command Entry Front mounted keypad, 4 tactile feedback pushbuttons
Gas Sensors Alarm Indicator Unit
Neutralization System
SpecificationsCapacity 1000kg/hr
Consist of (2)Scrubbers(1) NaoH pump(1) Turbo blower(1) Piping(300A) (1) NaOH Storage Tank
Tank
Dimension L4800*D2300*H1500
Material Mild steel(6t) + Rubber lining(3t)
Capacity 12m2
Scrubbers
Dimension H2000*Ф1300
Material Mild steel(6t) + Rubber lining(3t)
Consisting of Spray nozzle, PP Polling, Inspection glass etc.
NaOH pump
Type Vertical centrifugal pump
Material SS316, SS304
Power 5.5kW, 3 Phase, 380 VAC, 60 Hz
Head 15mH
Water Flow 0.8m³/min
Turbo blower
Type Turbo fan
Material FRP(Fiber-reinforced plastic)
Power 5.5Kw, 3 Phase, 380 VAC, 60Hz
Head 200mmAq
Water Flow 60m³/min
Series NS4200100kg/hr & 1000kg/hr
Packaged Panel
Weighing Scale
Ejector
Vacuum Regulator
Instrunment Vacuum Gauge, Pressure Transmitter, Pressure Switch
Gas Pressure Line(Pipe & Fitting)Forged Fittings, Ammonia Union, Ball Valve, Motorized-valve, Gas Filter
Comlete Supply Ranges of Chlorination System
Control Package & Accessories
Type Self-standing typeSize Approx. W900xD500xH2100Power 380/440VAC, 3 Phase, 50/60HzMaterial SS304+Painting or SS400+paintingConsisting of Touch Panel & PLC & UPSCommunication RS232C or RS485(Optional)
Type Electronic Load Cell typeMaterial Mild Steel + Epoxy coatedRange 200~400kg, 2,000~10,000kg
Consisting ofPlatform, Load cell, Summing boxDigital Indicator, Roller@Roller trunnion
IndicatorIndivation Type DigitalContacts H/L AlarmOutput 4~20mA(RS 232 Standard, RS 485)
Type Fixed Orifice typeMaterial Hi-impact PVCSize 1"~4"Consisting of Nozzle, throat, check valve, drain valve
Type Wall mounted, Diaphragm typeMaterial Hi-impact PVC, PTFE, Viton etc.
Consisting ofBody, Diaphram, Pressure gauge, Leg heater
Allowed pressure Max. 1.0MpaWorking vacuum Presssure
7"HG~30"HG
Contacts(option) Gas H/L pressure alarm