cemicl pmps - arrowengine.biz
Post on 30-May-2022
7 Views
Preview:
TRANSCRIPT
CHEMICAL PUMPS10, 12, 430, 500, 510 & 1200A SOLAR SERIES
CPOVERVIEW-ML-S-FEb15
ENGINE COMPANY
VOLUMETRIC CONVERSION
Nitrate hardened stainless plungers. All fluid ends stain-less trimmed.
One gland wrench per pump and one line check per fluid end furnished with each pump.
Outside stroke length adjust-ment for each fluid end.
Steel or stainless fluid ends. Fluid ends are available with metal-to-metal seats and TFE packing at no extra charge when ordered on new pumps.
Resilient seat heads and line checks are fitted with Buna-N O-Rings. Viton furnished upon request at no extra charge.
PLUNGERSIZE
MAXIMUM DISCHARGE PRESSURE MODEL NO.
MAXIMUM* QUARTS/DAY
SIN
GLE
HEA
D 3/16” 3000 PSI 10-B 12
1/4” 3000 PSI 10-B 22
3/8” 3000 PSI 10-B 55
1/2” 1500 PSI 10-B 92
DO
UBL
E H
EAD 3/16” 3000 PSI 10-2B 24
1/4” 3000 PSI 10-2B 44
3/8” 3000 PSI 10-2B 110
1/2” 1500 PSI 10-2B 184
CAPACITY DATA
* Minimum Quarts/Day 10% of maximum.
In 1955 Arrow Engine Company opened for business, beginning the tradition of providing premium service and exceptional products to the oil & gas industry, as well as the industrial engine market, throughout the world.
Arrow is a part of the Engineered Components segment formed by TriMas Corporation. Headquartered in Bloom� eld Hills, Michigan, TriMas Corporation (NASDAQ-TRS) provides engineered and applied products for growing markets worldwide.
With a consistent focus on our customers’ needs, striving to help them grow their business, and producing the most reliable equipment and parts in the industry, Arrow has forged a tradition of excellence since 1955.
ENGINE COMPANY10 SERIES
0
5
10
15
203/16" 1/4" 3/8" 1/2"
4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92
MAXIMUM QUARTS PER DAY
STR
OKES
PER
MIN
UTE
www.Arrowengine.com • 1-800-331-3662ENGINE COMPANY
All 300 Series stainless steel construction.
Packing gland Grease Jack for positive lubrication.
Either horizontal or vertical suc-tion entry to the pump.
Up to 1" stroke available, out-side adjustable.
1/4" and 1/2" plunger available.
Up to 50 strokes per minute available, outside adjustable.
2 ¼” Piston.
Furnished with stainless steel line check valve.
Optional supply gas filter and regulator available for higher supply gas pressures.
0
STROKESvs QUARTS
24 48 96 144 192 240 288
QUARTS PER DAY
STR
OKES
PER
MIN
UTE
1”
STR
OKE
10
20
30
40
50
601/4" Plunger
1/2" Plunger
CAPACITY DATA
PLUNGERSUPPLY
PRESSUREDISCHARGE PRESSURE
PRESSURE RATIOS
1/4" (6.3MM)15/75 PSI
1-5.1 ATMS5500 Max.374 ATMS 73.3
1/2" (12.7MM)15/75 PSI
1-5.1 ATMS1500 Max.102 ATMS 17.6
12 SERIES
CHEMICALSUPPLY
CHEMICALDISCHARGE
AIR / GASSUPPLY
EXHAUST
www.Arrowengine.com • 1-800-331-3662ENGINE COMPANY
Arrow’s proven & reliable 3/8" head in ductile or stainless
Compact Design
Easy Installation
Securable Battery Enclosure
Optional mounting base with anchoring stakes
The Arrow SCP-1200 Solar Powered Chemical Injection Pump is powered by a 12VDC motor, but requires no external power source. Through use of solar energy, an AGM high-rate sealed lead acid battery is con-tinuously recharged, allowing the battery to provide around-the-clock energy to the chemi-cal injector pump.
Electric motor driven, positive displacement pump.
Worm gear drive available in 3 different standard ratios and four plunger sizes to provide a wide selection of volumes and pressures from 1 QPD up to 80 GPD per head against pressures up to 2400 PSIG.
Standard packed plunger injec-tor head features trouble-free built in priming valves.
Standard pumps are available with high strength ductile iron or 316 stainless steel fluid ends to handle a wide variety of chemicals used in oil and gas production facilities, pipelines, process plants and other ap-plications where a rugged, easy-to-maintain propor-tioning pump is required.
MAX VOLUME (U.S. GALLONS PER DAY)
PLUNGER SIZE
MAXIMUM DISCHARGE PRESSURE
100:1 RATIO 50:1 RATIO 25:1 RATIO
MODEL NO.
MAX GPD**
MODEL NO.
MAX GPD**
MODEL NO.
MAX GPD**
60 HZ MOTOR
1725 RPM
50 HZ* MOTOR
1450 RPM
60 HZ MOTOR
1725 RPM
50 HZ* MOTOR
1450 RPM
60 HZ MOTOR
1725 RPM
50 HZ* MOTOR
1450 RPM
SIN
GLE
HEA
D 3/16" 3000 PSI 431-1.5S 2.5 2.07 430-1.5S 5 4.1 433-1.5S 10 8.3
1/4" 2400 PSI 431-2 5 4.15 430-2 10 8.3 433-2 20 16.6
3/8" 1200 PSI 431-3 12 9.96 430-3 23 19.09 433-3 46 38.18
1/2" 600 PSI 431-4 21 17.43 430-4 40 33.2 433-4 80 66.4
DO
UBL
E H
EAD 3/16" 3000 PSI 431-21.5S 5 4.1 430-21.5S 10 8.3 433-21.5S 20 16.6
1/4" 2400 PSI 431-22 10 8.3 430-22 20 16.6 433-22 40 33.2
3/8" 1200 PSI 431-23 24 19.9 430-23 46 38.18 433-23 92 76.4
1/2" 600 PSI 431-24 42 34.86 430-24 80 66.4 433-24 160 132.8
CAPACITY DATA
PLUNGER
MAXIMUM DISCHARGE PRESSURE
MAXIMUM PUMPING VOLUME
3/8" 1200 PSI 5 GPD 10 GPD
CAPACITY DATA
The system has been designed to reliably operate at maximum volume on as little as 3.6 ‘Sun-hours per day’* with up to 5 days of autonomy.**
The SCP-1200 uses Arrow’s reli-able injector heads, standard with 3/8” diameter stainless steel plunger.
Available in either single or double head configurations with steel (standard) or 316 stainless steel heads for corro-sion protection.
The pumping volume, con-trolled by Arrow’s custom timer, can range from 1 to 5 gallons per day with a single head and up to 10 gallons per day with dual heads. The pump-ing volume is dispersed evenly over a 24 hour period. The 3/8” plunger allows for pumping pressures up to 1200 psi (lbf per square inch). * This is based on full solar panel operation of 4.5 amp charging current, and ‘Sun-hours
per day’ refer to solar insolation measured in kilowatt-hours per square meter per day.
** This is based on a new Werker WKHR12-100C/FR battery
* Allow 10 to 12 weeks delivery time on 50 Hz motors.
** GPD = Gallons per 24-hour day.
1200 SERIES
430
www.Arrowengine.com • 1-800-331-3662ENGINE COMPANY
PLUNGER SIZE
MAXIMUM DISCHARGE PRESSURE
MODEL NO MAXIMUM
GALLONS/DAYHARD
PACKINGSOFT
PACKING
1/4" 12,000 3,000 500-2 16
3/8" 12,000 3,000 500-3 43
1/2" 12,000 3,000 500-4 85
3/4" 5,000 3,000 500-7 160
1" N/A 3,000 500-8 320
1 ¼" N/A 2,000 500-9 600
Plunger Size
Operating Ratio Gas/Fluid
3/16" 1200/1
1/4" 750/1
3/8" 300/1
1/2" 180/1
CAPACITY DATA
Resilient seat heads and line checks are fitted with Buna-N O-Rings. Viton furnished upon request at no extra charge.
Built-in priming valve.
Steel or stainless fluid ends.
Pump heads are available with metal-to-metal seats and Teflon packing at no extra charge when ordered on a new pump.
Steel or stainless fluid ends.
Pump heads are available with metal-to-metal seats and TFE packing at no extra charge when ordered on new pumps.
Resilient seat heads and line checks are fitted with Buna-N O-Rings. Viton furnished upon request at no extra charge.
Available with Pilot valve or Microvalve.
Discharge pressure to 6,000 PSI.
One gland wrench and one line check furnished with each pump.
VOLUMETRIC CONVERSIONPOWER END TO FLUID END RATIO
GAS CONSUMPTION CHARTStandard Cubic Feet of Gas Required to Pump One Gallon
VOLUMETRIC CONVERSION80
70
60
50
40
30
20
20 40 60 80 300 400 500 600 700 800
10
0 200100
GALLONS PER DAY
STR
OKES
PER
MIN
UTE
Minimum Operating SpeedMinimum Operating Speed
1 ¼" long
1 ¼" short
1" short
¾" long
¾" sho
rt
⅜" l
ong
½" long
½"
shor
t
¼"
shor
t¼
" lo
ng
1" lo
ng
Continuous ServiceContinuous Service
Maximum Operating SpeedIntermittent ServiceMaximum Operating SpeedIntermittent Service
QUARTS PER DAY
STR
OKES
PER
MIN
UTE
200
3
6
9
12
15
18
21
24
27
30
40 60 80 100 120 140
87 6
5
43 2 1
1/2" Plunger Full Stroke (1")13/8" PlungerFull Stroke (1")21/2" Plunger1/3 Stroke31/4" Plunger1/3 Stroke43/8" Plunger1/3 Stroke53/16" PlungerFull Stroke61/4" Plunger1/3 Stroke73/16" Plunger1/3 Stroke8
Piston Size 1/2" 3/8" 1/4" 3/16"
Stroke Full 1/3 Full 1/3 Full 1/3 Full 1/3
Inje
ctio
n Pr
essu
re In
PSI
6000 374 1122 497 1491 589 1776
5000 355 1065 405 1215 575 1725
4000 314 942 369 1107 560 1680
3500 95 285 278 834 355 1065 555 1665
3000 84 252 243 729 340 1020 545 1635
2000 76 228 185 555 308 924 530 1590
1500 71 213 177 531 288 864 476 1428
1000 62 186 164 492 270 810 469 1407
500 57 171 148 444 248 744 462 1386
200 54 162 126 378 245 735 458 1374
100 53 159 120 360 244 732 457 1371
500510 SERIES
www.Arrowengine.com • 1-800-331-3662ENGINE COMPANY
ATOMIZER Makes chemical more effective by breaking it up at point of injection.
Accelerates the mixing of liquids or promotes atomization of liquid into gas.
Use for line check or as a backup for line check.
All stainless steel construction.
LINE CHECKS Available in 1/4" brass (ASA-676) 3000 PSI max working pressure.
Available in 1/4" stainless steel (ASA-675) 6000 PSI max working pressure.
Available in 1/2" stainless steel (ASB-283) 6000 PSI max working pressure.
TANK PATCHES Special heat treated, shear proof, solid hinge pin.
Wetted parts, heavy duty cadmium plated.
Thick 1/8” neoprene gaskets.
Installation is easy with only a screwdriver and wrench.
Patches a 3/4” to 2” hole.
GAUGESPART NO. DESCRIPTION
ASB-871-NS Tank gauge for a 5-gal tank (new style)
ASB-871-B-S Tank gauge for a 5-gallon tank
ASB-871-LV Barrel gauge for a 55-gallon barrel
Team up the AM-0001 Atomizer with an Arrow Chemical Pump for
the best possible combination
PART NO. DESCRIPTION
AS-316 Tank Patch w/Lever Operation
A line check should be installed in the discharge line as close to the point of
injection as possible to prevent backup and contamination of chemical.
Low maintenance Microvalve replaces ASA-4147 lapped disk.
Operates slowly, one stroke every two minutes to twenty strokes per minute.
Kit available to convert existing pumps, part number ASB-446-MV.
Replace the Pilot Valve Assem-bly in your 5100 Series TXT or older 510 Arrow Pump with the new Microvalve assembly.
Original pilot valve with replaceable seat available.
510 SERIES CHEMPUMP
WITH PILOT VALVE
500 SERIES CHEMPUMP
WITH PILOT VALVE
510 SERIES CHEMPUMP WITH
MICROVALVE
500 SERIES CHEMPUMP WITH
MICROVALVE
OPTIONALACCESSORIES
MICROVALVE
Arrow Engine Company2301 East Independence • Tulsa, Oklahoma 74110fax (918) 699-2202local (918) 583-5711
toll free (800) 331-3662 www. ArrowEngine.com
Waukesha®, VHP®, and VGF® are registered trademarks of GE., Caterpillar®, is a registered trademark of Caterpillar, Inc., Fairbanks Morse® is a registered trademark of Coltec Industries, Inc., and Ajax® is a registered trademark of Cameron International Corporation.
Copyright © 2015 Arrow Engine Company
ENGINE COMPANY
REPLACEMENT PARTS
C-SERIES C-46 C-66 C-96 C-101 C-106 C-255
A-SERIES A-32 A-42 A-54 A-62A-62 TurboA-62 Genset
A-90A-90 TurboA-90 Genset
A-160A-160 TurboA-160 Genset
K-SERIES K6
L-SERIES L-795
CATERPILLAR® G379 G398 G399 G3304 G3306
WAUKESHA® F2895F3521F5108
L5790L7042
P9390 145G/F817140G/F554
F18H24WAK/1197
FAIRBANKS® ZC-118 ZC-208 ZC-503 ZC-739 ZC-346
AJAX® 5× 6½ EA-22, 6½ × 8 CMAEA30, 7½ × 10 CMAEA-30, 7¼ × 8 CMAE-42, 8½ × 10 CMA
DP-60, 9½ × 10 CMADP-115/230, 13½ × 16DP-70/80/160, 11 × 14 CMA
GAS PRODUCTS Meter RunsMeter Skids
Volume TanksCoalescersStructural Skids
2 & 3-Phase SeparatorsFuel Gas Cond. Skid
Heater TreaterIndirect HeaterH2S Scavenger Unit
Dehydration UnitLiquid Stabilizer
CHEMICAL PUMPS 10 Series(beam operated)
430 Series(electric)
12, 500, & 510 Series(pneumatic)
Solar Chemical Pumps
OEM & Aftermarket Spare Parts
COMPRESSION PRODUCTS
Compressor FramesVRC-2VRS-2VRS-4 (Coming Soon)
CNG Compressor Frames & PackagesVRC-CNG
Vapor Recovery UnitsVRU-1VRU-2
Gas Lift PackagesElectric HPGas Engine (VR, A-Series, Cat)
Custom Compression Packages
top related