Measuring andMonitoring
Relays
interface
607
608 Subject to change without further notice
interfaceinterfaceMeasuring and monitoring relaysContents
Selection by function 610
General information 612
Voltage and current measuring relays Voltage measuring relays NMU 1001 616SUM 1001 620
Current measuring relays NMI 1001 624SIM 1001 628
Current/voltage measuring relays SXT 12 632SXT 32 632
Voltage monitor (single phase) SUW 1001 635
Network monitoring relays Phase sequence – phase failure relay SAM 1001 638
Phase sequence – phase failure relays SPW 1004 641SPW 1005 641
Phase sequence relays SAP 1002 644SAP 1003 644
Voltage monitors (three-phase) SUW 3001 647DNU 650
Safety monitor DSU 652
Rotation direction indicator DRA 654
Measuring and monitoring relays Load monitors motor – cos phi SBW 1004 656SBW 1005 656SBW 1007 659
Motor temperature monitors SMS 1002 662SMS 1002-101 662SMS 1005 662SMS 1006 665
Contents – Measuring and monitoring relaysPage
interfaceinterfaceMeasuring and monitoring relaysContents
609
Temperature monitors Thermal resistance Pt 100 STW 1101 668STW 1102 668
Thermocouples NiCr-Ni STW 1001 671STW 1002 671
Control relays Lamp testers / diode gates NLT 1001 674NLT 1003 676
Contact protection relays SST 12 678KST 12 678
Accessories Z 29 681
Discontinued models 682
Contents – Measuring and monitoring relaysPage
Subject to change without further notice
610 Subject to change without further notice
CATALOG PAGE
APPLICATION
Voltage measuring relay Surpassing the lower or upper limit valueSurpassing the lower and upper limit value
Current measuring relay Surpassing the lower or upper limit valueThree-phase monitoring Phase sequence (clockwise rotation)
Phase failureVoltage imbalanceVoltage feedback detectionUndervoltage
Motor protection relay Underload detection cos ϕOverload detection cos ϕTemperature monitor PTC
Temperature monitor Thermal resistance Pt 100Thermocouple NiCr-Ni
Lamp tester Common anodesCathodes and anodes separated
Contact protection relay Electrical isolationCONTACTS Change-over contacts
Normally open contactNormally closed contactDiodes
OPERATION PRINCIPLE Open-circuit principleClosed-circuit principle
RATED VOLTAGE
Direct current DC 24 VSingle-phase current AC 24 V
AC/DC 24 VAC 110 VAC 110 – 127 VAC 115 VAC 115 – 120 VAC 220 – 240 VAC 230 VAC 230 – 240 V
Three-phase current 3 AC 220 V3 AC 400 V3 AC 380 – 415 V3 AC 440 – 480 V
SPECIAL FEATURES Without auxiliary supply voltageFault/error memoryRestart lockoutAdjustable hysteresisAdjustable response timeAdjustable response/release timeFixed response/release timeDigital (D) or analog (A) settings
HOUSING Modular housing 22.5 mm 45 mm48 mm
interfaceinterfaceMeasuring and monitoring relays Selection by function
611Subject to change without further notice
interfaceN
MU
1001
SU
M 1
001
NM
I 1001
SIM
1001
SX
T 1
2
SX
T 3
2
SU
W 1
001
SA
M 1
001
SP
W 1
004
SP
W 1
005
SA
P 1
002
SA
P 1
003
SU
W 3
001
SB
W 1
004
SB
W 1
005
SB
W 1
007
SM
S 1
002
SM
S 1
002-1
01
SM
S 1
005
SM
S 1
006
ST
W 1
101
ST
W 1
102
ST
W 1
001
ST
W 1
002
NLT
1001
NLT
1003
SS
T 1
2
KS
T 1
2
DN
U
DS
U
DR
A
Measuring and monitoring relays Selection by function
616 620 624 628 632 632 635 638 641 641 644 644 647 656 656 659 662 662 662 665 668 668 671 671 674 676 678 678 650 652 654
• • • ••
• • • •• • • • • •• • • • •• • • •• • •
• • • •• •
•• • • •
• •• •
••
• •1 1 2 2 2 2 2 1 1 2 2 1 1 1 1 1 2 2 1 1 2 2 2 2 1 2
1 1 1
1 1 1
11 6
• • • • • • • •• • • • • • • • • • • • • • • • • • • • • • •
• • • •• • • • •
••
• • • •• •
• •• • • • • • • • • • •
• • •• •
•• • • •
• • • • • • • •• • • •
• • • • • • • • • • • •• • • • •
•• • • • • •• • • •
• •• • • • • • • • •
A A A A A A A A A A A A D D D D A A A
• • • • •• • • • • • • • • • • • • • • • • • • • • • •
• • •
612 Subject to change without further notice
interfaceinterfaceMeasuring and monitoring relays General information
The following statements apply to all devices, unless
contradirected by the information contained in the device’s
specific technical data sheet.
Standards
The devices meet the current standards and regulations:“Measuring relays and protective facilities” EN 60255-6:1994
“Thermal protection for rotating electrical machines” EN 60947-8:2003
“Low-voltage switching devices” EN 60947-5-1:2004
“Insulation monitoring devices for monitoring of AC networksthrough a superimposed DC voltage” VDE 0413-2:1973 DIN EN 61557-2:1998
“Equipping of power systems with electronic devices” EN 50178:1997
Rated voltage UN
The voltage type is represented by the indication AC, DC orAC/DC of the relevant rated voltage.
V AC
These devices are designed for operation under AC voltage. The corresponding rated frequency is indicated.
V DC
These devices are designed for operation under DC voltage. We have indicated either the permissible amplitude and themaximum value of the voltage characteristic of thesuperimposed AC voltage according to DIN 41755-1 or the ratedfrequency. Devices for which a rated frequency has beenindicated, can also be operated at an unfiltered voltage from abridge rectification (no half-wave rectification). In this case theoperating voltage is the root-mean-square value of the voltage.
Ud = arithmetic mean valueuuess = amplitude (peak-to-peak displacement)û = absolute maximum value of the voltage characteristic = umax
AC/DC
These devices are designed for operation under AC and DC voltage.They can be operated with an unfiltered voltage from a bridgerectification (no half-wave rectification). The operating voltage is theroot-mean-square value of the voltage.
Operating voltage range
If the rated voltage is indicated as a range, for example 110 to 127 Vand a permissible operating range between 0.8 and 1.1 x UN, theoperating range will extend from 0.8 x 110 V to 1.1 x 127 V.
Rated frequency
The devices can be operated within the indicated range, forexample 50 to 60 Hz, without any restrictions. When 50 to 60 Hzis indicated, the devices have a frequency selector. When 50 or60 Hz is indicated, the devices are designed for the relevantfrequency.
Operating range
0.95 to 1.05 x rated frequency. When a rated frequency range isindicated, for example 50 to 60 Hz, the permissible operatingrange is 0.95 x 50 Hz to 1.05 x 60 Hz.
Rated consumption
Devices that are designed for operation with AC voltage arespecified in VA and W corresponding to the rated frequency. Ifseveral rated frequencies are indicated, or a range, the indicationwill always refer to 50 Hz. For devices designed for operationwith DC voltage, the values are indicated for a DC voltagewithout superimposition. For devices designed for operationunder AC and DC voltage, the same values are indicated as forAC devices. When the consumption changes during thefunctional sequence, the highest value is always indicated. If thedevice‘s consumption can be higher for a short period of time, forexample at power ON (DC system, economy connection), itsvalue will be indicated additionally. Due to capacitors in thepower supply, an increased switch-on peak occurs in electronicdevices.
Release value
When the devices are operated through inductive proximityswitches in 2-wire designs or through long lines in case of ACvoltage, a residual voltage is still applied to the devices, althoughthe excitation voltage has been switched off. For properfunctioning of the devices this voltage must be lower than therelease value. LEDs for function indications may burn weakly incase of a residual voltage.
613Subject to change without further notice
interfaceMeasuring and monitoring relays General information
Half-wave rectification
Various devices are equipped with an internal half-waverectification. As the devices must be adjusted for operation with2-wire inductive proximity switches, their half-wave rectificationvalue is indicated in the key data.
Inductive proximity switches in 2-wire design
Inductive proximity switches are subject to specified values forthe residual current that is allowed to flow over the load whenthe switch is disabled. These maximum values contradict therequirement for power consumption of the triggered contactorsand relays to be as low as possible. The market offers inductiveproximity switches with far lower residual currents. In order toadjust them to the required data of the switches, a field devicecan be added parallel to the load (mandatory for field deviceswith integrated half-wave rectification). Not all relays can beoperated parallel to the control input, pulse input or zero inputwith an additional load. A corresponding indication is made foreach device under “Technical data”.
Ambient temperature
Measured at a distance of 10 mm above the center of the upperhousing surface.
Storage and transport temperature
– 25 °C to + 70 °C.
Operating mode
Continuous operation
Climate resistance
Tested according to DIN 50016 (humid alternating atmospherewith 24-hour cycle, 83 % relative humidity at 23 °C and 92 %relative humidity at 40 °C).
Vibration resistance
Tested according to EN 60068-2-6:1995; frequency range 10 to55 Hz; amplitude 0.35 mm; acceleration 5 g, 20 frequency cyclesper axis (1 h 45 min).
Installation position
any
Degree of protection
In accordance with EN 60529:2000. The protection degree forhousing and connections can be found in the housing data in thissection.
Recovery time
For proper functioning of the device, the value must not fallbelow the specified value. See the function diagram for additionalinformation. This value does not imply that an interruption ispermissible.
Mean value of the fault
Deviation of the arithmetic mean value of all the measured valuesfrom the pre-selected value.
Analog setting
The indications relate to end value of the range.
Fixed values
The indications relate to the rated value.
Dispersion
Dispersion means the difference between the smallestmeasured value and the largest measured value at a certainsetting and constant setting variable values. The indications forthe devices relate to the pre-selected time value.
Influence of the supply voltage
If an additional error is caused by changing the supply voltage,this influence is indicated in % for each % of change to thesupply voltage. The rated value is the reference point. Thisindication refers to the entire operating range.
Influence of the ambient temperature
If an additional error is caused by changing the ambienttemperature, this influence is indicated in % for each K oftemperature change. The reference point is + 20 °C. Thisindication refers to the entire operating range.
Fault influence
If an influence occurs that exceeds the standard value, it must beindicated accordingly.
Digital
Never set all the selector switches to zero. The position of theselector switches should not be changed during the functionalsequence, as otherwise this may cause functional faults.
Creepage distances and clearances
DIN VDE 0110-1:1997 (EN 60664-1:2003)
614 Subject to change without further notice
interfaceinterfaceMeasuring and monitoring relays General information
Rated impulse voltage
See the “Technical data” of the device for the correspondingvalues.
Overvoltage category
See the “Technical data” of the device for the correspondingvalues.
Pollution degree
Outside; in the device: See the “Technical data” of the device forthe corresponding values.
Rated voltage
See the “Technical data” of the device for the correspondingvalues.
Contacts
Output circuit according to EN 60947-5-1:2004.
Contact material
The contact material is indicated in “Technical data”. So far,there is no known contact material that would be perfect for thevariety of application options. The major characteristics of themost important contact materials are listed in the following.
Hard silver
Ag Cu has good conductivity, a high resistance to corrosion and alow welding tendency. It is suitable for medium to high switchingcapacities. An especially sulfurous atmosphere facilitates theoxidation that may cause contact interruptions. Ag Cu is notsuitable for switching voltages < 6 V.
Silver-cadmium oxide
(Variations indicated with letter W) Ag Cd O contacts have alower welding tendency, a higher resistance to corrosion and abetter arc extinction than Ag Cu contacts. Therefore they areespecially well suited for switching inductive and capacitiveloads. Its oxidation resistance is higher than that of Ag Cu. Ag Cd O is not suitable for switching voltages < 12 V.
Silver nickel
Ag Ni, an important material for inductive loads (6 – 380 V). Suitable for switch-on current between 10 mA and 100 A. Thecontacts have good resistance to corrosion, a low weldingtendency and higher contact resistances than Ag contacts.
Silver alloy, gold-plated
Silver alloys with a high resistance to corrosion (Ag Ni, Ag Sn O2)are used underneath the gold plating, so that the same life spanas with Ag Ni, Ag Cd O or Ag Sn O2 can be expected after thegold plating is permeated through higher or inductive loads. Lowvoltages and currents are safely switched with gold plating.Please ensure that the gold layer, if required, is not destroyed byimproper use prior to the contact’s intended use.
Switching voltage
Rated value Un: see the upper limit value under “Technical data”:1.1 x Un
Current
Max. continuous current In: 5 A
Short-circuit protection
Fuse insert according to EN 60269-1:1998 and EN 60269-2:1995;utilization category gG, max. 6 A. – gG identifies overall fuseinserts for general applications.
Breaking capacity
Standard contact material
AC load in W, VAVoltage V AC 24 42 115 230cos ϕ 0.7 to 1 150 250 500 500inductive cos ϕ ≈ 0.3 50 80 150 200
DC load in WVoltage V DC 24 60 115 230R load 100 100 80 80L load ≈ 200 ms 30 35 40 40
Contact life span and making capacity
Standard contact material Load: AC 230 V, cos ϕ ≈ 0.3Operating Operating Power ON Power OFFcycles frequencySch Sch/h104 20 10 A 1 A105 50 5 A 0.5 A106 500 3 A 0.3 A107 3000 1 A 0.1 A
615Subject to change without further notice
interfaceMeasuring and monitoring relays General information
Application category
In EN 60497-5-1:2004, application categories are indicated forauxiliary circuit switches. They clearly define the intendedpurpose of the switching devices in combination with the ratedoperating voltage Ue, the rated operating current Ie, the numberof operating cycles and the test cycle.
Voltage type Application category Typicalapplication
AC voltage AC15 Controlling of electromagn. load (>72 VA)
DC voltage DC13 Controlling of electromagn.
Rated operating voltage Ue and current IeAC15 DC13
Ue Ie Ie24 V 3 A 2 A
115 V 3 A 0.2 A230 V 3 A 0.1 A400 V 2 A 0.05 A
The permissible switching voltage Un (see “Technical data”)must be adhered to.
Terminal markings and position of the terminals
All devices designed for operation under DC voltage areprotected against destruction in case of incorrect wiring. If thisprotection is designed as bridge rectification, the device will workproperly even in the case of incorrect poling. In this case, thecircuit diagram of the corresponding device‘s will not show anypolarity. If the poling protection is designed as half-waverectification, the device will not work in the case of incorrectpoling. For an optimal interference suppression of device‘sdesigned for AC voltage, terminal A1 should be assigned to L1and terminal A2 to N. When a control-power transformer is used,terminal A2 should always be assigned to the line common for allload bearing devices. In the circuit diagrams in the catalog, theposition of the terminals corresponds to the assignment on thedevice.
EC directives and declaration of conformity
This general technical information applies for all the devices thatmay be covered by one or more of the following EC directives:
EC Machine Directive 98/37/EGEC EMC Directive 89/336/EWGEC Low-Voltage Directive 73/23/EWG
The conformity of the devices that meet the requirements of thecorresponding EC directive is indicated by the CE mark ofconformity on the type plate. Information about which directivesand standards are met by the devices is provided by the ECDeclaration of Conformity. If the devices identified as such do notmeet all the directives during the directive’s transition period, thiswill be mentioned in the documents that accompany the device.The devices without the EC mark of conformity meet therespective standards indicated. This indication functions asdeclaration of conformity in the sense of article 10 of the ECLow-Voltage Directive 73/23. The devices that were put on themarket after 1995-12-31 must meet the requirements of theEMC Directive. In case of replacement devices that cannot beoperated on their own and do not carry the CE mark, the userhimself is responsible for the proper installation according to § 5 sec. 5 EMVG and for the fulfillment of the protectionrequirements according to § 4 sec. 1 EMVG. Wieland ElectricGmbH will provide users with the EC declarations of conformityon request.
Safety instructions
Installation, start-up, modification and retrofit of all devices mustbe performed by a qualified electrician only! Disconnect thedevice/system from the load prior to starting any work! Followthe safety instructions of electrical engineering and the tradeassociation! Negligence of the safety instructions may causedeath, grievous bodily harm or severe material damage!
Changes
We reserve the right to make technical changes that result intechnological advance.
616 Subject to change without further notice
Voltage measuring relay
• For monitoring the upper and lower limit values of single phase voltages• 3 measuring ranges from AC/DC 0.5 to 500 V• Sinusoidal, square, delta waveforms• 16 ON-delay times selectable: no delay, 0.1 s to 3 h• Frequency range of the measuring variable between 45 and 400 Hz• Multi-functional: Open-circuit or closed-circuit principle; hysteresis 3 % or
10 % from the setpoint
Applications
• Monitoring of voltage levels• Monitoring of interference voltage in networks with external power supply• Monitoring of field excitation of motors• Monitoring of frequency drives• Monitoring of analog correcting variables
Functions
The NMU 1001 is a monitoring relay with three measuring ranges for single-phasevoltages between AC/DC 0.5 V and AC/DC 500 V. The frequency range covers 45 Hzto 400 Hz at AC. The measured value is recorded with an integrated full wave rectifier.Therefore it is possible to monitor non-sinusoidal currents or voltages (e.g. voltageswith harmonic component). With AC, the devices evaluate the rectifier value calibratedon the root-mean-square of a sine voltage. With DC measuring values, a rectification isperformed and the mean value is monitored. The effective value itself is notmonitored. As output contact, 1 change-over contact is available. There is an electricalisolation between the auxiliary supply, the measuring circuit and the output circuit(relay contact).
The three measuring ranges are adjusted through the different connections of theinput terminals B1, B2, B3 and B4. The response value is adjusted with thepotentiometer Vx. The device functions and the ON-delay time are adjusted by usingthe rotary switches (see “Settings”).
Function of the open-circuit principle
After applying the supply voltage and transgression of the lower limit (<) or upper limit(>) values of the pre-selected response value, the output relay switches into the ONposition. This occurs according to the pre-selected ON-delay time. When themonitoring variable returns to the response value, the output relay switches into theOFF position depending on the adjustment of the hysteresis ( 3 % or 10 %).
Function of the closed-circuit principle
After applying the supply voltage and after the standby time tB, the output relayswitches into the ON position. The transgression of the lower limit (<) or upper limit(>) of the pre-selected response value, according to the selected function, causes theoutput relay to switch back into the OFF position depending on the pre-selected ON-delay time. When the monitoring variable returns to the response value, theoutput relay switches into the ON position depending on the adjustment of thehysteresis (3 % or 10 %).
Notes
• Operation of the function switch or the time switch during the timing period willimmediately terminate the timing operation.
• With the delay “–” (no delay) and with simultaneous active function (of the responsevalue), the NMU 1001 will respond to the instantaneous value of the monitoringvariable at a certain threshold and cause the output relay to switch into “quick time”(see “Response time” under “Technical data”).
• Disconnect the connection cables of the voltage measuring relay prior to performingan insulation or voltage test.
Circuit diagram
interfaceinterfaceMeasuring and monitoring relays Voltage measuring relay NMU 1001
617Subject to change without further notice
interfaceMeasuring and monitoring relaysVoltage measuring relay NMU 1001
Setting example:
Setpoint (response value) AC/DC 4 V ON-delay time withoutFunction underflow, closed-circuit principle, 10 % hysteresis
Settings:• Measuring range AC/DC 0.55 to 5 V (terminals B1 and B2)• Potentiometer Vx set to 0.8 (0.8 x measuring range end value 5 V) = 4 V
(response value)• Rotary switch ON-DELAY set to “–”• Function rotary switch set to > 10
If the measured value falls below the response value of 4 V, the output relay will switchinto the OFF position without an ON-delay time, and the LED TRIPPED will light. If the actual monitoring value exceeds the response value plus the hysteresis of 10 %,the output relay will switch into the ON position. The LED TRIPPED will extinguish (seeFunction diagram).
Application examples
Setting example:
Setpoint (response value) AC/DC 25 V ON-delay time 100 sFunction overrange, open-circuit principle, 3 % hysteresis
Settings: • Measuring range AC/DC 5 to 50 V (terminals B1 and B3)• Poti Vx set to 0.5 (0.5 x measuring range end value 50 V) = 25 V (response value)• Rotary switch ON-DELAY set to 100 s• Function rotary switch set to > 3
If the monitoring value exceeds the response value of 25 V, the LED TRIPPED will beginto flash. After the pre-selected ON-delay time of 100 s, the output relay switches intothe ON position and the LED TRIPPED burns continuously. If the actual monitoringvalue falls below the response value minus the hysteresis of 3 %, the output relay willswitch back into its OFF position. If it falls below the response value before the pre-selected ON-delay time is reached, the LED TRIPPED will extinguish (see the Functiondiagram).
U meas
U meas
618 Subject to change without further notice
interfaceinterfaceMeasuring and monitoring relays Voltage measuring relay NMU 1001
Settings
Measuring ranges
Response value Connection Internal Frequency Permissiblerange resistance overvoltage
(continuous)0.5 – 5 V AC/DC B1 – B2 11.3 kΩ 45 – 400 Hz 25 V5 – 50 V AC/DC B1 – B3 102.2 kΩ 45 – 400 Hz 250 V50 – 500 V AC/DC B1 – B4 1.022 MΩ 45 – 400 Hz 625 V ** Observe the rated voltage and overvoltage category
Response values
Analog setting of the response value via potentiometer Vx with factor 0.1 to 1. Theresponse value results from multiplying the upper value of the measuring rangewith the adjusted factor.
ON-delay time
Rotary switch ON-DELAY 0.1 s 30 s0.3 s 100 s0.5 s 3 min1 s 10 min
1.5 s 30 min3 s 1 h5 s 3 h
10 s – (no delay)
Functions
Rotary switch VOLTAGE HYSTERESIS MODE(principle)
>10 Overrange approx.10 % Open-circuit principle>10 Overrange approx.10 % Closed-circuit principle> 3 Overrange approx.3 % Open-circuit principle> 3 Overrange approx.3 % Closed-circuit principle<10 Underflow approx.10 % Open-circuit principle<10 Underflow approx.10 % Closed-circuit principle< 3 Underflow approx.3 % Open-circuit principle< 3 Underflow approx.3 % Closed-circuit principle– – – – – –
Function diagram
NMU 1001
Dimension diagram
Power supplyLED SUPPLYMonitoring value Response value(overrange mode Hysteresisof the response value >)Monitoring value (underflow mode Hysteresisof the response value <) Response valueLED TRIPPEDOutput contact 15/18Open-circuit principle 15/16Output contact 15/18Closed-circuit principle 15/16
tB = stand-by timetA = response time
Operation of the timeswitch or the functionswitch during thetiming period willimmediately terminatethe timing operation.
Overview of the devices/Part numbers
Type Measuring range Rated voltage Part number Std. Pack
NMU 1001 AC/DC 0.5 – 500 V DC 24 V R3.185.0430.0 1AC 24 V 50 – 60 Hz R3.185.0420.0 1AC 115 – 120 V 50 – 60 Hz R3.185.0440.0 1AC 230 – 240 V 50 – 60 Hz R3.185.0450.0 1
619Subject to change without further notice
interfaceMeasuring and monitoring relays Voltage measuring relay NMU 1001
Technical data
Type of function according to DIN EN 60255-6:11.94Function controlPower supply circuit
Rated voltage UN ACDC
Rated consumption set to 50 Hz and UN
Rated consumption set to 50 Hz and UN
Maximum inrush current set to UN (< 1 ms)Rated frequencyOperating voltage rangeParallel loads permissibleMeasuring circuit (DC or sinusoidal measuring voltage)Electrical isolation from power supply circuitSetting/number of measuring rangesSetting range hysteresisDispersionInfluence of the supply voltageInfluence of the ambient temperatureRated frequency range of the measured valueMinimum pulse length of the measured valueMinimum pulse length of the response value at ON-delay “–”Time circuit
Mean value of the faultDispersionInfluence of the supply voltageInfluence of the ambient temperatureOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current InMinimal contact loadApplication category according to EN 60947-5-1:1991Permissible switching frequencyMechanical lifeElectrical life 20/2 A, AC 250 V, cos ϕ = 0.3Response time set to “–” and > V (AC 50 Hz)
Response time set to “–” and > V (DC)
Release time set to “–” and > V
Release time set to 0.1 s – 3 h
Minimum pulse time of output relayAvailability time of measurement tB after power supply switch-onOverride time of measurement after power ONGeneral data
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageRated impulse voltageTest voltage of the circuitsTest voltage contact / contact
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92InsulationAmbient temperature, operating rangeDimension diagramRated cross sections fine-stranded/solid
or fine-stranded with ferrulesMaximum tightening torqueWeightAccessoriesApprovals
NMU 1001
Voltage measuring relay with open-circuit and closed-circuit principle1 green LED, 1 red LED
24 V 115 – 120 V 230 – 240 V24 V
2.5 VA 2.5 VA 2.5 VA1 W 2.3 W 2.3 W 2.3 W1 A 1.2 A 0.25 A 0.13 A50 – 60 Hz0.8 – 1.1xUN
yes
yes analog/3approx. 3 % and approx. 10 % of the response value, adjustable≤ ± 0.5 %≤ ± 0.05 %/% ∆UN
≤ ± 0.05 %/K∆T45 – 400 Hz 25 ms with overrange/underflow of the DC response value1 ms with 1.5 times overrange of the DC response value
< 5 % of the end value≤ ± 0.2 % + ≤ 50 ms≤ ± 0.02 %/% ∆UN
≤ ± 0.005 %/K∆T
1 change-over contactAg alloy, gold-platedAC/DC 240 V 5 AAC/DC 5 V / AC/DC 10 mAAC-15: Ue 230 V AC, Ie 3 A / DC-13: Ue 24 V DC, Ie 2 A≤ 3600 switching cycles/h30x106 switching cycles0.12x106 switching cycles AC-15≤ 80 ms at 1.05 times the response value of the measured value≈ 25 ms at 1.3 times the response value of the measured value (quick time)≤ 50 ms at 1.1 times the response value of the measured value≈ 15 ms at 1.6 times the response value of the measured value (quick time)≈ 30 ms after 1.1 times the response value of the measured value≤ 150 ms after 1.6 times the response value of the measured value≈ 30 ms after 1.1 times the response value of the measured value≈ 35 ms after 1.6 times the response value of the measured value> 100 ms≤ 100 ms≤ 60 ms
according to DIN VDE 0110-1:04.975 kVIII3 outside, 2 inside500 V5 kV (1.2 /50 µs); 4 kV (1.2 /50 µs) for DC 24 V device2.7 kVeff (50 Hz)2.5 kVeff (50 Hz)IP 40/ IP 20according to VDE 0110 sec. 1.2:01.89–20 – +60 °CK 3-32x0.2 – 2.5 mm2/2x0.2 – 2.5 mm2
1 or 2x0.2 – 1.5 mm2
1 Nm0.2 kg––
620 Subject to change without further notice
Voltage measuring relay
• For monitoring the upper and lower limit values of single phase voltages• 3 measuring ranges from AC/DC 0.5 to 500 V• Sinusoidal, square, delta waveforms• 10 time ranges: no delay, 0.1 s to 3 h for the ON-delay time• Frequency range of the measured value between 45 and 400 Hz• Multi-functional: open-circuit or closed-circuit principle; hysteresis 3 % or
10 % from the setpoint
Applications
• Monitoring of voltage levels• Monitoring of interference voltage in networks with external power supply• Monitoring of field excitation of motors• Monitoring of frequency drives• Monitoring of correcting variables
Functions
The voltage measuring relay SUM 1001 is a monitoring relay for single-phase voltages.The measured value is fed in through different terminals (see table I) according to thedesired measuring range. With the setpoint potentiometer, the response value can beadjusted analogically within the pre-selected measuring range. The on-time delay can beadjusted with the time range switch and the time setpoint potentiometer (see table II).
Function of the open-circuit principle
After applying the supply voltage and transgression of the lower or upper limit values(depending on the selected function – see table III) of the pre-selected response value,the output relay switches into the ON position. This occurs either according to the pre-selected ON-delay time or immediately. The transgression of the limit values(underflow or overrange) of the response value, according to the selected function, byat least 3 % or 10 % (hysteresis) causes the output relay to switch back into the OFFposition.
Function of the closed-circuit principle
After applying the supply voltage, the relay switches into the ON position after tB. Thetransgression of the lower or upper pre-selected limit values, according to the selectedfunction, causes the output relay to switch back into the OFF position depending onthe pre-selected ON-delay time. Depending on the pre-selected hysteresis (3 % or 10 %), the output relay switches back into the ON position after the correspondingtransgression of the lower or upper response value.
Notes
• The power supply is electrically isolated from the measuring circuit and isdisplayed by LED SUPPLY.
• The measured value is recorded with an integrated full wave rectifier. Thereforeit is possible to monitor non-sinusoidal voltages (e.g. voltages with harmonic,square or delta voltages ranging between 45 and 400 Hz).
• With AC, the devices evaluate the rectifier value calibrated on the root-mean-square of a sine voltage.
• With DC measuring values, a rectification is performed and the mean value ismonitored.
• With NO DELAY and simultaneous active function overrange (> V), themonitoring relays will respond to the instantaneous value of the monitoringvariable at a certain threshold and cause the output relay to switch into “quicktime” (see Technical Data).
• Disconnect the connection cables of the voltage measuring relay prior toperforming an insulation or voltage test.
Circuit diagram
interfaceinterfaceMeasuring and monitoring relays Voltage measuring relay SUM 1001
Lw
621Subject to change without further notice
interfaceMeasuring and monitoring relays Voltage measuring relay SUM 1001
Setting example:
Setpoint (response value) AC/DC 4 V ON-delay time withoutFunction underflow, closed-circuit principle, 10 % hysteresis
Table I:• Measuring range 1 (terminals B1 and B2)• Potentiomenter setpoint set to 0.8 (0.8 x measuring range end value 5 V) = 4 V
(setpoint)
Table II:• Time range end value NO DELAY• Potentiometer setpoint set to any value = without ON-delay time
Table III:• Function < V 10 %• Function selector in position 8
If the measured value falls below the setpoint of 4 V, the output relay will switch intothe OFF position without an ON-delay time, and the LED TRIPPED will light. If theactual measured value exceeds the setpoint plus the hysteresis of 10 %, the outputrelay will switch into the ON position. The LED TRIPPED will extinguish (see Functiondiagram 4).
Application examples
Setting example:
Setpoint (response value) AC/DC 25 V ON-delay time 210 sFunction overrange, open-circuit principle, 3 % hysteresis
Table I:• Measuring range 2 (terminals B1 and B3)• Potentiomenter setpoint set to 0.5 (0.5 x measuring range end value 50 V) = 25 V
(setpoint)
Table II:• Time range end value 300 s• Time potentiometer setpoint set to 0.7 (0.7 x time range end value 300 s) = 210 s
(ON-delay time)
Table III:• Function > V 3 %• Function selector in position 4
If the measured value exceeds the setpoint of 25 V, the LED TRIPPED will begin to flash.After the pre-selected ON-delay time of 210 s, the output relay switches into the ONposition and the LED TRIPPED burns continuously. If the actual measured value fallsbelow the setpoint minus the hysteresis of 3 %, the output relay will switch back into itsOFF position. If it falls below the measured value before the pre-selected ON-delay timeis reached, the LED TRIPPED will extinguish (see Function diagram 1).
U meas
U meas
622 Subject to change without further notice
interfaceinterfaceMeasuring and monitoring relays Voltage measuring relay SUM 1001
Function diagrams
SUM 1001 FD 0242-5-1 W1
Measured value overrange > V, open-circuit principle
FD 0242-5-2 W1
Measured value overrange > V, closed-circuit principle
FD 0242-5-3 W1
Measured value underflow < V, open-circuit principle
FD 0242-5-4 W1
Measured value underflow < V, closed-circuit principle
Overview of the devices/Part numbers
Type Measuring range Rated voltage Part number Std. Pack
SUM 1001 AC/DC 0.5 – 500 V AC 115 V 50 – 60 Hz R3.185.0290.0 1AC 230 V 50 – 60 Hz R3.185.0220.0 1
Dimension diagram
Settings
Table I:
Measuring range Connection Internal Frequency PermissibleNum • AC/DC resistance overvoltage
(continuous)1 • 0.5 bis 5 V B1 – B2 11.3 kΩ 45 – 400 Hz 25 V2 • 5 bis 50 V B1 – B3 102.2 kΩ 45 – 400 Hz 250 V3 • 50 bis 500 V B1 – B4 1.022 MΩ 45 – 400 Hz 625 V ** Observe the rated voltage and overvoltage category
Table II:
Time range Value1 s 0.1 s to 1 s3 s 0.3 s to 3 s
10 s 1 s to 10 s30 s 3 s to 30 s
100 s 10 s to 100 s300 s 30 s to 300 s
1000 s 100 s to 1000 s1 h 0.1 h to 1 h3 h 0.3 h to 3 h
NO DELAY no delay
Table III:
Switch Monitoring Principle HysteresisFunction of output relay> V 3 % Overrange Open-circuit principle 3 %> V 3 % Overrange Closed-circuit principle 3 %< V 3 % Underflow Open-circuit principle 3 %< V 3 % Underflow Closed-circuit principle 3 %> V 10 % Overrange Open-circuit principle 10 %> V 10 % Overrange Closed-circuit principle 10 %< V 10 % Underflow Open-circuit principle 10 %< V 10 % Underflow Closed-circuit principle 10 %
Supply voltageLED SUPPLY green Max. value Setpoint Hysteresis Min. value LED TRIPPED red17/1825/26
> measured value
Supply voltageLED SUPPLY green Max. value Setpoint Hysteresis Min. value LED TRIPPED red17/1825/26
> measured value
Supply voltageLED SUPPLY greenMax. value Setpoint Hysteresis Min. value LED TRIPPED red17/1825/26
> measured value
Supply voltageLED SUPPLY green Max. value Setpoint Hysteresis Min. value LED TRIPPED red17/1825/26
> measured value
for DIN rail according to EN 50022
tA = adjustable ON-delay timetB = availability time of measurement after power supply switch-on
tA = adjustable ON-delay timetB = availability time of measurement after power supply switch-on
tA = adjustable ON-delay timetB = availability time of measurement after power supply switch-on
tA = adjustable ON-delay timetB = availability time of measurement after power supply switch-on
Operation of the timeswitch or the functionswitch during the timingperiod will immediatelyterminate the timingoperation.
623Subject to change without further notice
interfaceMeasuring and monitoring relaysVoltage measuring relay SUM 1001
Technical data
Type of function according to DIN EN 60255-6:11.94Function controlFunction diagramPower supply circuit
Rated voltage UN ACRated consumption set to 50 Hz and UN (AC)Rated consumption set to 50 Hz and UN (AC)Maximum inrush current set to UN (< 1 ms)Rated frequencyOperating voltage rangeParallel loads permissibleMeasuring circuit (DC or sinusoidal measuring voltage)Electrical isolation from power supply circuitSetting / Number of measuring rangesSetting ranges Measuring circuit – Response valuesSetting ranges Measuring circuit – Hysteresis valuesON-delay timeDispersionInfluence of the supply voltageInfluence of the ambient temperatureRated frequency range of the measured valueMinimum pulse length of the measured valueMinimum pulse length of the measured value at NO DELAYTime circuit
Mean value of the faultDispersionInfluence of the supply voltageInfluence of the ambient temperatureOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current In per contactApplication category according to EN 60947-5-1:1991Short circuit protection; max. fuse insert class gGPermissible switching frequencyMechanical lifeResponse time set to NO-DELAY and > V (AC 50 Hz)
Response time set to NO-DELAY and > V (DC)
Release time set to NO-DELAY and > V
Release time set to 0.1 s to 3 h
Minimum pulse time of output relayAvailability time of measurement after power ONOverride time of measurement after power ONGeneral information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Noise immunity according to IEC 61000-4Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
SUM 1001
Voltage measuring relay with open-circuit and closed-circuit principle1 green LED, 1 red LEDFD 0242-5-1 W1 – FD 0242-5-4 W1
115 V 230 V
2.5 VA 2.5 VA2.3 W 2.3 W0.25 A 0.13 A50 – 60 Hz0.8 – 1.1 x UN
yes
yesanalog / 3see Table Iapprox. 3 % and approx. 10 % of the response value, adjustablesee Table II≤ ± 0.5 %≤ ± 0.05 % / % ∆UN
≤ ± 0.05 % / K∆T45 – 400 Hz AC, DC25 ms with overrange/underflow of the DC response value1 ms with 1.5 times overrange of the DC response value
< 5 % of the end value≤ ± 0.2 % + ≤ 50 ms≤ ± 0.02 % / % ∆UN≤ ± 0.005 % / K∆T
1 normally closed, 1 normally openAg alloy, gold-platedAC/DC 230/230 V 5 AAC-15: Ue 230 V AC, Ie 3 A / DC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles≤ 80 ms at 1.05 times the response value of the measured value≈ 25 ms at 1.3 times the response value of the measured value (quick time)≤ 50 ms at 1.1 times the response value of the measured value≈ 15 ms at 1.6 times the response value of the measured value (quick time)≈ 30 ms after 1.1 times the response value of the measured value≤ 150 ms after 1.6 times the response value of the measured value≈ 30 ms after 1.1 times the response value of the measured value≈ 35 ms after 1.6 times the response value of the measured value> 100 ms, during elapse of the minimum pulse time, this is reset when the relay is energized again
≤ 100 ms≤ 60 ms
according to DIN VDE 0110-1:04.975 kVIII3 outside, 2 inside500 V AC2.7 kVIP 40 / IP 20Test severity 3–20 – +60 °CS 7-1KS 0338/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.3 kg–
Lw
624 Subject to change without further notice
Current measuring relay
• For monitoring the upper and lower limit values of single phase voltages• 2 designs, each with measuring ranges between AC/DC 2 and 500 mA
or 0.1 and 15 A• Sinusoidal, square, delta waveforms• 16 ON-delay times selectable: no delay, 0.1 s to 3 h• Frequency range of the measuring variable between 45 and 400 Hz• Multi-functional: Open-circuit or closed-circuit principle; hysteresis 3 %
or 10 % from the setpoint
Applications
• Monitoring of current levels• Monitoring of power requirements• Monitoring of frequency drives• Monitoring of correcting variables• Monitoring of heating elements
Functions
The NMI 1001 is a monitoring relay for single-phase currents. There are two typeswith different measuring ranges. The frequency range covers 45 Hz to 400 Hz at AC.The measured value is recorded with an integrated full wave rectifier. Therefore it ispossible to monitor non-sinusoidal currents (e.g. currents with harmonic component).With AC, the devices evaluate the rectifier value calibrated on the root-mean-square ofa sine voltage. With DC measuring values, a rectification is performed and the mean value ismonitored. The effective value itself is not monitored. As output contact, 1 change-over contact is available. There is an electrical isolation between the auxiliary supply,the measuring circuit and the output circuit (relay contact).
The three measuring ranges are adjusted through the different connections of theinput terminals B1, B2, B3 and B4. The response value is adjusted with thepotentiometer Ix. The device functions and the ON-delay time are adjusted by usingthe rotary switches (see “Settings”).
Function of the open-circuit principle
After applying the supply voltage and transgression of the lower limit (<) or upper limit(>) values of the pre-selected response value, the output relay switches into the ONposition. This occurs according to the pre-selected ON-delay time. When themonitoring variable returns to the response value, the output relay switches into theOFF position depending on the adjustment of the hysteresis ( 3 % or 10 %).
Function of the closed-circuit principle
After applying the supply voltage and after the standby time tB, the output relayswitches into the ON position. The transgression of the lower limit (<) or upper limit(>) of the pre-selected response value, according to the selected function, causes theoutput relay to switch back into the OFF position depending on the pre-selected ON-delay time. When the monitoring variable returns to the response value, the outputrelay switches into the ON position depending on adjustment of the hysteresis (3 % or 10 %).
Notes
• Operation of the function switch or the time switch during the timing period willimmediately terminate the timing operation.
• With the delay “–” (no delay) and simultaneous active function overflow (of theresponse value), the NMI 1001 will respond to the instantaneous value of themonitoring variable at a certain threshold and cause the output relay to switch into“quick time” (see the ‘Response time’ under Technical Data).
• Disconnect the connection cables of the current measuring relay prior to performingan insulation or voltage test.
Circuit diagram
interfaceinterfaceMeasuring and monitoring relays Current measuring relay NMI 1001
625Subject to change without further notice
interfaceMeasuring and monitoring relays Current measuring relay NMI 1001
Setting example NMI 1001 0.1 – 15 A:
Setpoint (response value) AC/DC 12 A ON-delay time withoutFunction underflow, closed-circuit principle, 10 % hysteresis
Settings:• Measuring range AC/DC 1.5 to 15 A (terminals B1 and B4)• Potentiometer Ix set to 0.8 (0.8 x measuring range end value 15 A) = 12 A (setpoint)• Rotary switch ON-DELAY set to “–”• Function rotary switch set to > 10
If the monitoring value falls below the setpoint of 12 A, the output relay will switch intothe OFF position without an ON-delay time, and the LED TRIPPED will light. If the actual monitoring value exceeds the response value plus the hysteresis of 10 %,the output relay will switch into the ON position. The LED TRIPPED will extinguish (see Function diagram).
Application examples
Setting example NMI 1001 2 – 500 mA:
Setpoint (response value) AC/DC 50 mA ON-delay time 100 sFunction overrange, open-circuit principle, 3 % hysteresis
Settings:• Measuring range AC/DC 10 to 100 mA (terminals B1 and B3)• Potentiometer Ix set to 0.5 (0.5 x measuring range end value 100 mA) = 50 mA (setpoint)• Rotary switch ON-DELAY set to 100 s• Function rotary switch set to > 3
If the monitoring value exceeds the setpoint of 50 mA, the LED TRIPPED will begin toflash. After the pre-selected ON-delay time of 100s, the output relay switches into theON position and the LED TRIPPED burns continuously. If the actual monitoring valuefalls below the response value minus the hysteresis of 3 %, the output relay will switchback into the OFF position. If it falls below the response value before the pre-selectedON-delay time is reached, the LED TRIPPED will extinguish (see the Function diagram).
meas
meas
626 Subject to change without further notice
interfaceinterfaceMeasuring and monitoring relays Current measuring relay NMI 1001
Function diagram
NMI 1001
Dimension diagram
Supply voltageLED SUPPLYMonitoring value Response value(Overrange mode Hysteresisof the response value >)Monitoring value(underflow mode Hysteresisof the response value <) Response valueLED TRIPPEDOutput contact 15/18Open-circuit principle 15/16Output contact 15/18Closed-circuit principle 15/16
tB = stand-by timetA = response time
Settings
Measuring range I NMI 1001 2 – 500 mA
Response value range Connection Internal resistance Frequency1 2 – 20 mA AC/DC B1 – B2 2.5 Ω 45 – 400 Hz2 10 – 100 mA AC/DC B1 – B3 500 mΩ 45 – 400 Hz3 50 – 500 mA AC/DC B1 – B4 100 mΩ 45 – 400 Hz
Permissible overcurrent Maximumfusing (slow)
continuous max. 3 s max. 10 sbreak 100 s break 100 s
1 0.05 A 0.2A 0.5 A 0.1 A2 0.25 A 1 A 2.5 A 0.4 A3 1.25 A 5 A 12 A 2.5 A
Measuring ranges II NMI 1001 0.1 – 15 A
Response value range Connection Internal resistance Frequency1 0.1 – 1 A AC/DC B1 – B2 50 mΩ 45 – 400 Hz2 0.5 – 5 A AC/DC B1 – B3 10 mΩ 45 – 400 Hz3 1.5 – 15 A AC/DC B1 – B4 3.33 mΩ 45 – 400 Hz
Permissible overcurrent Maximumfusing (slow)
continuous max. 3 s max. 10 sbreak 100 s break 100 s
1 2.5 A 10 A 25 A 5 A2 12.5 A 50 A 125 A 16 A3 21 A 50 A 125 A 25 A
Response values
Analog setting of the response value via potentiometer Ix with factor 0.1 to 1. Theresponse value results from multiplying the upper value of the measuring rangewith the adjustment factor.
ON-delay time
Rotary switch ON-DELAY 0.1 s 30 s0.3 s 100 s0.5 s 3 min1 s 10 min
1.5 s 30 min3 s 1 h5 s 3 h
10 s (no delay)
Functions
Rotary switch CURRENT HYSTERESIS MODE(principle)
> 10 Overrange approx. 10 % Open-circuit principle> 10 Overrange approx. 10 % Closed-circuit principle> 3 Overrange approx. 3 % Open-circuit principle> 3 Overrange approx. 3 % Closed-circuit principle< 10 Underflow approx. 10 % Open-circuit principle< 10 Underflow approx. 10 % Closed-circuit principle< 3 Underflow approx. 3 % Open-circuit principle< 3 Underflow approx. 3 % Closed-circuit principle– – – –
Operation of the timeswitch or the functionswitch during thetiming period willimmediately terminatethe timing operation.
Overview of the devices/Part numbers
Type Measuring range Rated voltage Part number Std. Pack
NMI 1001 AC/DC 2 – 500 mA DC 24 V R3.185.0350.0 1AC 24 V 50 – 60 Hz R3.185.0340.0 1AC 115 – 120 V 50 – 60 Hz R3.185.0370.0 1AC 230 – 240 V 50 – 60 Hz R3.185.0360.0 1
AC/DC 0.1 – 15 A DC 24 V R3.185.0390.0 1AC 24 V 50 – 60 Hz R3.185.0380.0 1AC 115 – 120 V 50 – 60 Hz R3.185.0410.0 1AC 230 – 240 V 50 – 60 Hz R3.185.0400.0 1
627Subject to change without further notice
interfaceMeasuring and monitoring relays Current measuring relay NMI 1001
Technical data
Function according to DIN EN 60255-6:11.94Function controlPower supply circuit
Rated voltage UN ACDC
Rated consumption set to 50 Hz and UN
Rated consumption set to 50 Hz and UN
Maximum inrush current set to UN (< 1 ms)Rated frequencyOperating voltage rangeParallel loads permissibleMeasuring circuit (DC or sinusoidal measuring voltage)Electrical isolation from power supply circuitSetting / Number of measuring rangesSetting range hysteresisDispersionInfluence of the supply voltageInfluence of the ambient temperatureRated frequency range of the measured valueMinimum pulse length of the measured valueMinimum pulse length of the response value at ON-delay “–”Time circuit
Mean value of the faultDispersionInfluence of the supply voltageInfluence of the ambient temperatureOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current InMinimal contact loadApplication category according to EN 60947-5-1:1991Permissible switching frequencyMechanical lifeElectrical life 20/2 A, AC 250 V, cos ϕ = 0.3Response time set to “–” and > V (AC 50 Hz)
Response time set to “–” and > V (DC)
Release time set to “–” and > V
Release time set to 0.1 s to 3 h
Minimum pulse time of output relayAvailability time of measurement tB after power supply switch-onOverride time of measurement after power ONGeneral information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageRated impulse voltageTest voltage of the circuitsTest voltage contact / contact
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92InsulationAmbient temperature, operating rangeDimension diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesMax. tightening torqueWeightAccessoriesApprovals
NMI 1001
Current measuring relay with open-circuit and closed-circuit principle1 green LED, 1 red LED
24 V 115 – 120 V 230 – 240 V
24 V
2.5 VA 2.5 VA 2.5 VA1 W 2.3 W 2.3 W 2.3 W1 A 1.2 A 0.25 A 0.13 A50 – 60 Hz0.8 – 1.1 x UN
yes
yesanalog / 3approx. 3 % and approx. 10 % of the response value, adjustable≤ ± 0.5 %≤ ± 0.05 % / % ∆UN
≤ ± 0.05 % / K∆T45 – 400 Hz 25 ms with overrange/underflow of the DC response value1 ms with 1.5 times overrange of the DC response value
< 5 % of the end value≤ ± 0.2 % + ≤ 50 ms≤ ± 0.02 % / % ∆UN
≤ ± 0.005 % / K∆T
1 change-over contactAg alloy, gold-platedAC/DC 240 V 5 AAC/DC 5 V / AC/DC 10 mAAC-15: Ue 230 V AC, Ie 3 A / DC-13: Ue 24 V DC, Ie 2 A≤ 3600 switching cycles/h30 x 106 switching cycles0.12 x 106 switching cycles AC-15≤ 80 ms at 1.05 times the response value of the measured value≈ 25 ms at 1.3 times the response value of the measured value (quick time)≤ 50 ms at 1.1 times the response value of the measured value≈ 15 ms at 1.6 times the response value of the measured value (quick time)≈ 30 ms after 1.1 times the response value of the measured value≤ 150 ms after 1.6 times the response value of the measured value≈ 30 ms after 1.1 times the response value of the measured value≈ 35 ms after 1.6 times the response value of the measured value> 100 ms≤ 100 ms≤ 60 ms
according to DIN VDE 0110-1:04.975 kVIII3 outside, 2 inside500 V5 kV (1.2 / 50 µs); 4 kV (1.2 / 50 µs) for DC 24 V device2.7 kVeff (50 Hz)2.5 kVeff (50 Hz)IP 40 / IP 20according to VDE 0110 sec. 1.2:01.89-20 – +60 °CK 3-32 x 0.2 – 2.5 mm2 / 2 x 0.2 – 2.5 mm2
1 or 2 x 0.2 – 1.5 mm2
1 Nm0.2 kg––
628 Subject to change without further notice
Current measuring relay
• For monitoring the upper and lower limit values of single phase voltages• 2 designs, each with measuring ranges between AC/DC 2 and 500 mA
or 0.1 and 15 A• Sinusoidal, square, delta waveforms• 10 time ranges: no delay, 0.1 s to 3 h for the ON-delay time• Frequency range of the measuring variable between 45 and 400 Hz• Multi-functional: Open-circuit or closed-circuit principle; hysteresis 3 % or
10 % from the setpoint
Applications
• Monitoring of current levels• Monitoring of power requirements• Monitoring of frequency drives• Monitoring of analog correcting variables• Monitoring of heating elements
Functions
The current measuring relay SUM 1001 is a monitoring relay for single-phase voltages.The measured value is fed in through different terminals (see table I) according to thedesired measuring range. With the setpoint potentiometer, the response value can beadjusted analogically within the pre-selected measuring range. The on-time delay can beadjusted with the time range switch and the time setpoint potentiometer (see table II).
Function of the open-circuit principle
After applying the supply voltage and transgression of the lower or upper limit values(depending on the selected function – see table III) of the pre-selected response value,the output relay switches into the ON position. This occurs either according to the pre-selected ON-delay time or immediately. The transgression of the limit values(underflow or overrange) of the response value, according to the selected function, byat least 3 % or 10 % (hysteresis) causes the output relay to switch back into the OFFposition.
Function of the closed-circuit principle
After applying the supply voltage, the relay switches into the ON position after tB. Thetransgression of the lower or upper pre-selected limit values, according to the selectedfunction, causes the output relay to switch back into the OFF position depending onthe pre-selected ON-delay time. Depending on the pre-selected hysteresis (3 % or 10 %), the output relay switches back into the ON position after the correspondingtransgression of the lower or upper response value.
Circuit diagram
Notes
• The power supply is electrically isolated from the measuring circuit and is displayedby LED SUPPLY.
• The measured value is recorded with an integrated full wave rectifier. Therefore it ispossible, in certain ranges, to monitor non-sinusoidal currents (e.g. currents withharmonic, square or delta voltages ranging between 45 and 400 Hz).
• With AC, the devices evaluate the rectifier value calibrated on the root-mean-squareof a sine voltage.
• With DC measuring values, a rectification is performed and the mean value ismonitored.
• With NO DELAY and simultaneous active function overrange (> V), the monitoringrelays will respond to the instantaneous value of the monitoring variable at a certainthreshold and cause the output relay to switch into “quick time” (see TechnicalData).
• Disconnect the connection cables of the voltage measuring relay prior to performingan insulation or voltage test.
interfaceinterfaceMeasuring and monitoring relaysCurrent measuring relay SIM 1001
Lw
629Subject to change without further notice
interfaceMeasuring and monitoring relays Current measuring relay SIM 1001
Setting example SIM 1001 0.1 – 15 A:
Setpoint (response value) AC/DC 12 AON-delay time withoutFunction underflow, closed-circuit principle, 10 % hysteresis
Table I:• Measuring range 3 (terminals B1 and B4)• Potentiometer setpoint set to 0.8 (0.8 x measuring range end value 15 A) = 12 A
(setpoint)
Table II:• Time range end value NO DELAY• Potentiometer setpoint set to any value = without ON-delay time
Table III:• Function < A 10 %• Function selector in position 8
If the measured value falls below the setpoint of 12 A, the output relay will switch intothe OFF position without an ON-delay time, and the LED TRIPPED will light. If the actualmeasured value exceeds the setpoint plus the hysteresis of 10 %, the output relay willswitch into the ON position. The LED TRIPPED will extinguish (see Function diagram 4).
Dimension diagram
Application examples
Setting example NMI 1001 2 – 500 mA:
Setpoint (response value) AC/DC 50 mA ON-delay time 210 sFunction overrange, open-circuit principle, 3 % hysteresis
Table I:• Measuring range 2 (terminals B1 and B3)• Potentiometer setpoint set to 0.5 (0.5 x measuring range end value 100 mA) =
50 mA (setpoint)
Table II:• Time range end value 300 s• Time potentiometer setpoint set to 0.7 (0.7 x time range end value 300 s) =
210 s (ON-delay time)
Table III:• Function > A 3 %• Function selector in position 4
If the measuring value exceeds the setpoint of 50 mA, the LED TRIPPED will begin toflash. After the pre-selected ON-delay time of 210 s, the output relay switches intothe ON position and the LED TRIPPED burns continuously. If the actual measuringvalue falls below the setpoint minus the hysteresis of 3 %, the output relay willswitch back into the OFF position. If it falls below the measured value before the pre-selected ON-delay time is reached, the LED TRIPPED will extinguish (see Functiondiagram 1).
meas
meas
for DIN rail according to EN 50022
630 Subject to change without further notice
interfaceinterfaceMeasuring and monitoring relays Current measuring relay SIM 1001
Function diagram
SIM 1001 FD 0242-5-1 W1
Measured value overrange > V, open-circuit principle
FD 0242-5-2 W1
Measured value overrange > V, closed-circuit principle
FD 0242-5-3 W1
Measured value underflow < V, open-circuit principle
FD 0242-5-4 W1
Measured value underflow < V, closed-circuit principle
Settings
Table Ia SIM 1001 2 – 500 mA
Response value range Connection Internal resistance Frequency1 2 – 20 mA AC/DC B1 – B2 2.5 Ω 45 – 400 Hz2 10 – 100 mA AC/DC B1 – B3 500 mΩ 45 – 400 Hz3 50 – 500 mA AC/DC B1 – B4 100 mΩ 45 – 400 Hz
Permissible overcurrent Maximumfusing (slow)
continuous max. 3 s max. 10 sbreak 100 s break 100 s
1 0.05 A 0.2A 0.5 A 0.1 A2 0.25 A 1 A 2.5 A 0.4 A3 1.25 A 5 A 12 A 2.5 A
Table Ib SIM 1001 0.1 – 15 A
Response value range Connection Internal resistance Frequency1 0.1 – 1 A AC/DC B1 – B2 50 mΩ 45 – 400 Hz2 0.5 – 5 A AC/DC B1 – B3 10 mΩ 45 – 400 Hz3 1.5 – 15 A AC/DC B1 – B4 3.33 mΩ 45 – 400 Hz
Permissible overcurrent Maximumfusing (slow)
continuous max. 3 s max. 10 sbreak 100 s break 100 s
1 2.5 A 10 A 25 A 5 A2 12.5 A 50 A 125 A 16 A3 21 A 50 A 125 A 25 A
Table II:
Time range Value1 s 0.1 s to 1 s3 s 0.3 s to 3 s
10 s 1 s to 10 s30 s 3 s to 30 s
100 s 10 s to 100 s300 s 30 s to 300 s
1000 s 100 s to 1000 s1 h 0.1 h to 1 h3 h 0.3 h to 3 h
NO DELAY no delay
Table III
SwitchFunction Monitoring Principle Hysteresis
of output relay> A 3 % Overrange Open-circuit principle 3 %> A 3 % Overrange Closed-circuit principle 3 %< A 3 % Overrange Open-circuit principle 3 %< A 3 % Overrange Closed-circuit principle 3 %> A 10 % Overrange Open-circuit principle 10 %> A 10 % Overrange Closed-circuit principle 10 %< A 10 % Underflow Open-circuit principle 10 %< A 10 % Underflow Closed-circuit principle 10 %
Operation of the timeswitch or the functionswitch during thetiming period willimmediately terminatethe timing operation.
Supply voltageLED SUPPLY green Max. value Setpoint Hysteresis Min. value LED TRIPPED red17/1825/26
> measured value
Supply voltageLED SUPPLY green Max. value Setpoint Hysteresis Min. value LED TRIPPED red17/1825/26
> measured value
Supply voltageLED SUPPLY green Max. value Setpoint Hysteresis Min. value LED TRIPPED red17/1825/26
> measured value
Supply voltageLED SUPPLY green Max. value Setpoint Hysteresis Min. value LED TRIPPED red17/1825/26
> measured value
Overview of the devices/Part numbers
Type Measuring range Rated voltage Part number Std. Pack
SIM 1001 AC/DC 2 – 500 mA AC 24 V 50 – 60 Hz R3.185.0280.0 1AC 115 V 50 – 60 Hz R3.185.0270.0 1AC 230 V 50 – 60 Hz R3.185.0210.0 1
AC/DC 0.1 – 15 A AC 24 V 50 – 60 Hz R3.185.0250.0 1AC 42 V 50 – 60 Hz R3.185.0230.0 1AC 115-120 V 50 – 60 Hz R3.185.0240.0 1AC 230-240 V 50 – 60 Hz R3.185.0200.0 1
tA = adjustable ON-delay timetB = availability time of measurement after power supply switch-on
tA = adjustable ON-delay timetB = availability time of measurement after power supply switch-on
tA = adjustable ON-delay timetB = availability time of measurement after power supply switch-on
tA = adjustable ON-delay timetB = availability time of measurement after power supply switch-on
631Subject to change without further notice
interfaceMeasuring and monitoring relays Current measuring relay SIM 1001
Technical data
Type of function according to DIN EN 60255-6:11.94Function controlFunction diagramPower supply circuit
Rated voltage UN ACRated consumption set to 50 Hz and UN (AC)Rated consumption set to 50 Hz and UN (AC)Maximum inrush current set to UN (< 1 ms)Rated frequencyOperating voltage rangeParallel loads permissibleMeasuring circuit (DC or sinusoidal measuring voltage)Electrical isolation from power supply circuitSetting / Number of measuring rangesSetting ranges Measuring circuit – Response valuesSetting ranges Measuring circuit – Hysteresis valuesON-delay timeDispersionInfluence of the supply voltageInfluence of the ambient temperatureRated frequency range of the measured valueMinimum pulse length of the measured valueMinimum pulse length of the measured value at NO DELAYTime circuit
Mean value of the faultDispersionInfluence of the supply voltageInfluence of the ambient temperatureOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current In per contactApplication category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gGPermissible switching frequencyMechanical lifeResponse time set to NO-DELAY and > V (AC 50 Hz)
Response time set to NO-DELAY and > V (DC)
Release time set to NO-DELAY and > V
Release time set to 0.1 s to 3 h
Minimum pulse time of output relayAvailability time of measurement after power ONGeneral information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Noise immunity according to IEC 61000-4Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
SIM 1001
Current measuring relay with open-circuit and closed-circuit principle1 green LED, 1 red LEDFD 0242-5-1 W1 – FD 0242-5-4 W1
24 V 115 V 230 V
2.5 VA 2.5 VA 2.5 VA2.3 W 2.3 W 2.3 W1.2 A 0.25 A 0.13 A50 – 60 Hz0.8 – 1.1 x UN
yes
yesanalog / 3see Table Iapprox. 3 % and approx. 10 % of the response value, adjustablesee Table II≤ ± 0.5 %≤ ± 0.05 % / % ∆UN
≤ ± 0.05 % / K∆T45 – 400 Hz AC, DC25 ms with overrange/underflow of the DC response value1 ms with 1.5 times overrange of the DC response value
< 5 % of the end value≤ ± 0.2 % + ≤ 50 ms≤ ± 0.02 % / % ∆UN
≤ ± 0.005 % / K∆T
1 normally closed, 1 normally openAg alloy, gold-platedAC/DC 230/230 V 5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles≤ 80 ms at 1.05 times the response value of the measured value≈ 25 ms at 1.3 times the response value of the measured value (quick time)≤ 50 ms at 1.1 times the response value of the measured value≈ 15 ms at 1.6 times the response value of the measured value (quick time)≈ 30 ms after 1.1 times the response value of the measured value≤ 150 ms after 1.6 times the response value of the measured value≈ 30 ms after 1.1 times the response value of the measured value≈ 35 ms after 1.6 times the response value of the measured value> 100 ms, during elapse of the minimum pulse time, this is reset when the relay is energized again≤ 100 ms
according to DIN VDE 0110-1:04.975 kVIII3 outside, 2 inside500 V AC2.7 kVIP 40 / IP 20Test severity 3-20 – +60 °CS 7-1KS 0337/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.3 kg–
Lw
632 Subject to change without further notice
Voltage or current measuring relay
• For monitoring the upper and lower limit values of single phase voltages• Response value selectable in a 1:10 ratio• Release value adjustable from to 50 to 95 % of the response value• With auxiliary voltage• SXT 12: Open-circuit principle
SXT 32: Closed-circuit principle
Applications
• Monitoring of field excitation of motors• Monitoring of interference voltage in networks with external power supply• Monitoring of overvoltage levels• Monitoring of overcurrent levels
Function
The measuring relay is connected to a permanent supply voltage of 50 to 60 Hz. Thecurrent or voltage to be monitored is supplied via terminals B1/B2. The supply voltagecircuit and the measuring circuit are electrically isolated by means of a transformer. A response value and a release value are set on the relay. If the measured valueexceeds the response value, the relay will switch. If the measured value falls belowthe release value, the relay will fall back into its initial position. The release value is adjustable within the range between 0.5 and 0.95 of the response value.
SXT 12 – open-circuit principle
When supply voltage is applied, the SXT 12 is in OFF position. If the response value is exceeded, it will switch into the ON position. If it falls below the release value, the relay will switch back into the OFF position.
SXT 32 – closed-circuit principle
When supply voltage is applied, the SXT 32 switches into the ON position. If theresponse value is exceeded, it will switch back into the OFF position. If it falls below the release value, the relay will switch back into the ON position.
Accessories
Cover Z 29
Notes
• Unfiltered or partially filtered DC voltages and currents can also be monitored in themeasuring circuit. It should be observed that the relay responds to the positive peakvalues, but is adjusted to the corresponding root-mean-square values at 50 Hz.
• Negative currents are not measured but also not influenced (same operating range as for the positive currents).
Circuit diagram
Measuring range U/I
Measuring range * Internal Rated Permiss. overcurrent/overvoltageresistance frequency continuous max. 3 s **
0.01 – 0.1 A AC 2 Ω 50 – 60 Hz 0.25 A AC 1 A AC0.05 – 0.5 A AC 400 mΩ 50 – 60 Hz 1.25 A AC 5 A AC0.1 – 1 A AC 200 mΩ 50 – 60 Hz 2.5 A AC 10 A AC0.5 – 5 A AC 10 mΩ 50 – 60 Hz 12.5 A AC 50 A AC1 – 10 A AC 5 mΩ 50 – 60 Hz 17.5 A AC 50 A AC
2 – 20 mA DC 10 Ω – 0.05 A DC 0.2 A DC0.1 – 1 A DC 200 mΩ – 2.5 A DC 10 A DC0.5 – 5 A DC 10 mΩ – 12.5 A DC 50 A DC1 – 10 A DC 5 mΩ – 17.5 A DC 50 A DC
0.5 – 5 V DC 125 Ω – 12.5 V DC –5 – 50 V DC 12.5 Ω – 125 V DC –
* all measuring ranges with half-wave rectifier** with break of 100 s until the next overload
Setting example:
• Measuring range end value x ratio factor = response value (ON)e.g. 10 A AC x 0.75 = 7.5 A AC
• Response value x ratio factor = release value (OFF)e.g. 7.5 A AC x 0.85 = 6.4 A AC
• Hysteresis: 7.5 A AC — 6.4 A AC = 1.1 A AC
interfaceinterfaceMeasuring and monitoring relays Current/voltage measuring relays SXT 12, SXT 32
Measuring circuit
w
633Subject to change without further notice
interfaceMeasuring and monitoring relays Current/voltage measuring relays SXT 12, SXT 32
Faultindicator
Load
Faultindicator
Tachogenerator
x response value
responseno
(ms) interference pulse width(ms) response time
for DIN rail according to EN 50022
Supply voltageLED SUPPLY green Max. valueResponse valueRelease valueMin. value LED TRIPPED red15/18; 25/2815/16; 25/26
> Meas.value
Supply voltageLED SUPPLY green Max. valueResponse valueRelease valueMin. value LED TRIPPED red15/18; 25/2815/16; 25/26
Meas. circuit
Meas. circuit
> Meas.value
Application examples RPM monitoring
The rpm delivered by the tachogenerator is transformed into a voltage measurement. This voltage (measured value) is monitored by the SXT 32 measuring relay. If thevoltage exceeds the pre-selected response value, the relay will switch into the OFFposition (closed-circuit principle). The fault will be indicated by lamp H1. The flow can be controlled by the PLC.
Response time
The response time is the time intervalbetween the occurrence of a measuredvalue and the change-over of the relay. It isinfluenced by the factor by which themeasured value exceeds the responsevalue. The permissible interference pulsewidth is the duration of an interferencepulse at which the relay does not yetrespond.
Current monitoring for the load
If the current in the load (measured value) exceeds the pre-selected response value,the relay switches into the OFF position (closed-circuit principle). The fault will beindicated by lamp H1. If the current falls below the release value, the relay will switchback into the operating position.
Function diagram
SXT 12 FD 0075 W1
SXT 32 FD 0076 W1
Dimension diagram
interfaceMeasuring and monitoring relays Current/voltage measuring relays SXT 12, SXT 32
634 Subject to change without further notice
interface
Overview of devices/Part numbers
Type Measuring range Rated voltage Part number Std. Pack
SXT 12 DC 0.1 – 1 A AC 220 – 240 V 50 – 60 Hz R3.185.0090.0 1DC 0.5 – 5 A AC 220 – 240 V 50 – 60 Hz R3.185.0050.0 1DC 1 – 10 A AC 220 – 240 V 50 – 60 Hz R3.185.0070.0 1DC 0.5 – 5 V AC 220 – 240 V 50 – 60 Hz R3.185.0140.0 1AC 0.01 – 0.1 A AC 220 – 240 V 50 – 60 Hz R3.185.0100.0 1AC 0.05 – 0.5 A AC 220 – 240 V 50 – 60 Hz R3.185.0170.0 1AC 0.1 – 1 A AC 110 – 127 V 50 – 60 Hz R3.185.0010.0 1
AC 220 – 240 V 50 – 60 Hz R3.185.0030.0 1AC 0.5 – 5 A AC 110 – 127 V 50 – 60 Hz R3.185.0160.0 1
AC 220 – 240 V 50 – 60 Hz R3.185.0040.0 1AC 1 – 10 A AC 220 – 240 V 50 – 60 Hz R3.185.0060.0 1
SXT 32 DC 2 – 20 mA AC 220 – 240 V 50 – 60 Hz R3.185.0180.0 1DC 5 – 50 V AC 220 – 240 V 50 – 60 Hz R3.185.0130.0 1AC 0.05 – 0.5 A AC 110 – 127 V 50 – 60 Hz R3.185.0330.0 1
AC 220 – 240 V 50 – 60 Hz R3.185.0150.0 1AC 0.1 – 1 A AC 110 – 127 V 50 – 60 Hz R3.185.0110.0 1
AC 220 – 240 V 50 – 60 Hz R3.185.0080.0 1
Technical data
Type of function according to DIN EN 60255-6:11.94
Function control Function diagramPower supply circuit ACRated voltage (UN)Rated consumption at 50 Hz and UN (AC) Rated consumption at 50 Hz and UN (AC) Rated frequency Operating voltage range Parallel loads permissibleMeasuring circuit
Electrical isolation from power supply circuit Setting / number of measuring ranges Setting ranges Measuring circuit – Response values Setting ranges Measuring circuit – Release values Dispersion Influence of the supply voltage Influence of the ambient temperatureOutput circuit
Contact assignment / contact material Rated operating voltage UN
Max. continuous current ln per contact Application category according to EN 60947-5-1:1991 Short circuit protection; max. fuse insert class gG Permissible switching frequency Mechanical life Response time tA
Release time tR
General information
Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage categoryPollution degree Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Conductor cross sections fine-stranded / solid or
fine-stranded with ferrules Permissible tightening torque Weight Accessories Approvals
SXT 12 SXT 32
Measuring relay with supply voltage Measuring relay with supply voltageOpen-circuit principle Closed-circuit principle1 green LED, 1 red LED 1 green LED, 1 red LEDFD 0075 W1 FD 0076 W1
110 – 127 V 220 – 240 V
2.5 VA 2.5 VA2.1 W 2.1 W50 – 60 Hz0.8 – 1.1 x UN
yes
yesanalog / 1see table “Measuring ranges U/I”0.5 – 0.95 x response value≤ ± 0.5 %≤ ± 0.5 % / % ∆UN
≤ ± 0.1 % / K∆T
2 change-over contacts / Ag alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 A DC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cyclessee diagram “Response time”30 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30/ IP 20Test severity 3-20 – +60 °CS 3 – 4KS 0233/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.24 kgCover Z 29
w
Setting ranges
Rated voltage UN
min. UN
max. UN
AC/DC 24 V 15 – 25 V 25 – 35 VAC 230 V 140 – 240 V 210 – 310 V
635Subject to change without further notice
interfaceMeasuring and monitoring relays Voltage monitor SUW 1001
Applications
• Monitoring of emergency power systems• Protection of EDP installations• Building protection engineering• Protection of PLC robot systems• RPM monitoring with generator• Monitoring of generator voltages
DC or AC monitor without auxiliary supply
• For single-phase networks• Large adjustment range and large operating range• Adjustable upper and lower limit• Closed-circuit principle
Accessories
CoverZ 29
Circuit diagram
Function
A lower and an upper limit value are set via potentiometers on the voltage monitor.After applying the supply voltage to terminals A1/A2, the voltage monitor switchesinto its operating position (closed-circuit principle). This requires, however, that theapplied voltage lies between the two pre-selected limit values. After transgression ofthe upper or lower limit value, the device switches into its OFF position.• An additional auxiliary supply voltage is not required (two-wire technology)• The limit values are set via potentiometers on the front of the unit • The switching hysteresis is set to an permanent value
Note
• No electrical isolation between the measuring and input circuits
636 Subject to change without further notice
interfaceinterfaceMeasuring and monitoring relays Voltage monitor SUW 1001
Application examples
Protection of robotic systems
The SUW 1001 prevents malfunctioning of the PLC robot system when the voltagefluctuations are too large.If the limit value is exceeded, damage is limited to the PLC(running in a safe mode), and an emergency shut-down is initiated for the robots.
Function diagram
Emergency power monitoring
The SUW 1001 monitors the main voltage.If the main voltage fails or if it differs from its design value, the system will switch overto a backup voltage (battery) (contacts 15-16, 25-26).
Dimension diagram
Response value> URelease value > URelease value < UResponse value< Umin. value
LED SUPPLY green
LED TRIPPED red
15/18; 25/2815/16; 25/26
> Meas.value
t1 Application of the supply voltage until excitation of SUW ≈ 150 mst2 Exceeding the response value > U up to drop out of SUW ≈ 20 mst3 Falling below the release value > U until excitation of SUW ≈ 50 mst4 Falling below the response value < U up to drop out of SUW ≈ 30 mst5 Exceeding the release value < U until excitation of SUW ≈ 50 mst6 Switch-off time, must be > recovery time = 700 ms
Hysteresis = response value — release value
for DIN rail according to EN 50022
Robot
Emerg.stop
Consumer
Battery
637Subject to change without further notice
interfaceMeasuring and monitoring relays Voltage monitor SUW 1001
SUW 1001
Voltage monitor without auxiliary supply voltage;upper and lower limit values adjustable;Closed-circuit principle1 green LED, 1 red LEDFD 0125 W1
24 V230 V
1.2 VA 1.6 VA0.9 W 1.4 W50 – 60 Hz0.5 – 1.1 x UN
yes
noanalog / 1see Table “Setting ranges”permanent, ≈ 3 % of end value max. U≤ ± 0.5 %≤ ± 0.02 % / % ∆UN
≤ ± 0.05 % / K∆T
2 change-over contactsAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles150 ms20 ms30 ms50 ms700 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3 – 4KS 03152 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.26 kgCover Z 29–
Type Rated voltage Part number Std. Pack
SUW 1001 AC 24 V 50 – 60 Hz R3.184.0020.0 1AC 230 V 50 – 60 Hz R3.184.0010.0 1
Technical data
Type of function according to DIN EN 60255-6:11.94
Function controlFunction diagramPower supply circuit
Rated voltage UN AC/DCAC
Rated consumption set to 50 Hz and UN (AC)Rated consumption set to 50 Hz and UN (AC)Rated frequencyOperating voltage rangeParallel loads permissibleMeasuring circuit
Electrical isolation from power supply circuitSetting / Number of measuring rangesSetting rangesSwitching hysteresisDispersionInfluence of the supply voltageInfluence of the ambient temperatureOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current In per contactApplication category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gGPermissible switching frequencyMechanical lifeResponse time t1
Response time t2
Response time t4
Release time t3/t5
Recovery timeGeneral information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Noise immunity according to IEC 61000-4Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
Overview of devices/Part numbers
638 Subject to change without further notice
Three-phase unbalanced – phase sequence – phase failure relays
without auxiliary supply voltage
• Detection of incorrect phase sequence• Detection of the failure of one or more phases• Recognition of voltage feedback in the event of phase failure• Adjustable phase voltage imbalance• Closed-circuit principle• Contact assignment: 2 change-over contacts
Applications
• Monitoring the supply voltage of installations such as:• Crane and elevator systems• Machines with reversal of rotational direction• Pumps, condensers or compressor systems• Air conditioning and ventilation systems• Distribution stations• Escalators
Function
The SAM 1001 monitors the external line voltages L1, L2, L3. It monitors:• whether three-phase voltages are applied• the phase sequence• the balanceIf the parameters are faultless, the SAM 1001 will switch into its ON position. If one ofthe conditions is not fulfilled, the relay will remain in its OFF position. The red LEDlights up. It is reset automatically after the fault has been eliminated.If a phase failure occurs during operation, this will be recognized even when a voltagefeedback occurs through a connected field device. The relay falls back into its OFFposition and the red LED lights up. An imbalance limit value can be set on the relay.A response time and release time of 1000 ms each is permanently set internally. It prevents the relay from responding during short-term imbalance voltage increasesor line breakdown. The relay will not switch in case of balance voltage drops in thenetwork.
Accessories
Cover Z 29
Circuit diagram
Setting ranges
The imbalance limit value can be adjusted analog from 5 to 15 %.
interfaceinterfaceMeasuring and monitoring relays Phase sequence – phase failure relay SAM 1001
w
639Subject to change without further notice
interfaceMeasuring and monitoring relays Phase sequence – phase failure relay SAM 1001
Application example
Monitoring a distribution station
The SAM 1001 monitors the operating voltage in a station. If the SAM 1001 reports afault such as a voltage imbalance, an incorrect phase sequence or a phase failure, therelay K1 will switch into the OFF position. The system is switched and the PLCevaluates the message system-specifically.
Dimension diagram Function diagram
for DIN rail according to EN 50022
System
Supply volt. LED SUPPLY
Incorrect phase sequence
> Pre-selected valueImbalanceHysteresis
Phase failure L1 or L2
Phase failure L3
LED TRIPPED
15/18; 25/2815/16; 25/26
tA = response valuetR = release value
interfaceMeasuring and monitoring relays Phase sequence – phase failure relay SAM 1001
640 Subject to change without further notice
interface
Technical data
Type of function according to DIN EN 60255-6:11.94
Function control Function diagramPower supply circuit
Rated voltage UN 3 ACRated consumption at 50 Hz and UN (AC)Rated consumption set to 50 Hz and UN (AC)Rated frequencyOperating voltage rangeMeasuring circuit
SettingsSetting range of the imbalanceDispersionInfluence of the supply voltageInfluence of the ambient temperatureOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current In per contactApplication category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gGPermissible switching frequencyMechanical lifeResponse time tA
Release time tR
General data
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Noise immunity according to IEC 61000-4Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
SAM 1001
Three-phase imbalance – phase sequence – phase failure relays,Closed-circuit principle1 green LED, 1 red LEDFD 0079 W1
220 V 380 – 415 V 440 – 480 V
3.8 VA 3.8 VA 3.8 VA3.3 W 3.3 W 3.3 W50 – 60 Hz0.8 – 1.15 x UN
analog5 to 15 %≤ ± 5 %≤ ± 0.05 % / % ∆UN
≤ ± 0.1 % / K∆T
2 change-over contactsAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles1000 ms1000 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3 – 9KS 0236/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.28 kgCover Z 29
w
Overview of devices/Part numbers
Type Rated voltage Part number Std. Pack
SAM 1001 3 AC 220 V 50 – 60 Hz R3.183.0010.0 13 AC 380 – 415 V 50 – 60 Hz R3.183.0020.0 13 AC 440 – 480 V 50 – 60 Hz R3.183.0030.0 1
641Subject to change without further notice
interfaceMeasuring and monitoring relays Phase sequence – phase failure relays SPW 1004, SPW 1005
Three-phase – phase sequence – phase failure relays without auxiliary
supply voltage
• Detection of incorrect phase sequence• Detection of phase voltage imbalance• Phase failure detection even at back-voltage with or without phase shift• Rated voltage of three-phase current adjustable to 3 AC 380 V, 400 V, 415 V
with corresponding undervoltage detection of one, two or all three phases• Closed-circuit principle, reaction time 35 ms for each fault detection• Contact assignment: SPW 1004 2 change-over contacts, SPW 1005 1
change-over contact
Applications
• Monitoring of three-phase current network fault on machines or systems, such as:• Processing machines, palletizing systems, packaging machines• Machines with reversal of rotational direction• Escalators and elevator systems• Pumps and compressors• Air conditioning and ventilation systems
Function
The SPW devices monitor their external line voltages (their own three-phase power supply) L1, L2, L3 for:• Phase sequence in clockwise rotation• Phase failure• Phase voltage imbalance• Phase shift• Undervoltage
After applying the external line voltages L1, L2, L3 and with correct three-phasecurrent parameters, the SPW switches into the ON position (closed-circuit principle).The green LED lights up. If one of the above mentioned conditions is not fulfilled, therelay will remain in or switch into its OFF position. The SPW operates without auxiliarysupply voltage and neutral connection. The rated voltage for the three-phase currentnetworks can be pre-selected in 3 ranges – 3 AC 380 V, 400 V, 415 V – analog with apotentiometer on the front of the device. If a fault occurs, the relay will switch into itsOFF position with a reaction time of 35 ms. The green LED will extinguish. After thefault has been removed, the SPW automatically switches into its ON position and theLED lights up.
Fault detection occurs at:• Incorrect phase sequence• Phase failure of 100%, such as wire breakage in the lines leading to the device• Phase failure even at back-voltage up to 85%• Undervoltage detection up to 20% of one, two or all three phases, related to the
adjusted voltage of 3 AC 380 V, 400 V, 415 V• Phase voltage imbalance above 15%• Phase shift of one phase compared to the other phases
The two devices differ in their contact assignments. The SPW 1004 is fitted with twochange-over contacts, while the SPW 1005 is fitted with one change-over contact.
Circuit diagramw
642 Subject to change without further notice
Application example
Monitoring of a system
The SPW monitors the pre-selected rated voltage range of the three-phase current in a system. If the SWP 1004 reports a fault such as an incorrect phase sequence, avoltage imbalance, an undervoltage or a phase failure, the relay K2 will switch into theOFF position. The system is switched and the PLC evaluates the message system-specifically.
Function diagram Dimension diagram
interfaceinterfaceMeasuring and monitoring relays Phase sequence – phase failure relays SPW 1004, SPW 1005
for DIN rail according to EN 50022Phases L1, L2, L3
Incorrect phase sequence
Phase failure L1 or L2 or L3
Imbalance
Undervoltage
LED TRIPPED
15/18;25/28 (25/26/28)15/16;25/26 only SPW 1004
tA = response valuetR = release value
System
643Subject to change without further notice
interfaceMeasuring and monitoring relays Phase sequence – phase failure relays SPW 1004, SPW 1005
Technical data
Type of function according to DIN EN 60255-6:11.94
Function controlFunction diagramPower supply circuit
Rated voltage UN 3 ACRated consumption set to 50 Hz and UN (AC)Rated consumption set to 50 Hz and UN (AC)Rated frequencyOperating voltage rangeMeasuring circuit
Setting range of the rated voltage UN
SettingsUndervoltage detectionPhase voltage imbalancePhase shiftPhase failure with feedbackDispersionInfluence of the supply voltageInfluence of the ambient temperatureHysteresis for undervoltage detectionHysteresis for phase voltage imbalanceOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current In per contactApplication category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gGPermissible switching frequencyMechanical lifeResponse time tA
Release time tR
Hysteresis for undervoltage detectionHysteresis for phase voltage imbalanceGeneral data
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Noise immunity according to IEC 61000-4Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
Overview of devices/Part numbers
SPW 1004 SPW 1005
Three-phase imbalance – phase sequence – phase failure relays,Closed-circuit principle1 LED greenFD 0079 W1
380, 400, 415 V
3.8 VA3.5 W50 – 60 Hz0.7 – 1.15 x UN
3 AC 380 – 400 – 415 Vanalog≈ 80 % UN
≥ ± 10 % bis ≤ ± 15 %≈ ± 6 °
– 85 % Uoperation
≤ ± 0.5 %≤ ± 0.02 % / % ∆UN
≤ ± 0.05 % / K∆T≈ 25 V≈ 15 V
2 change-over contacts 1 change-over contactAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles< 25 ms ± 10 ms depending on the phase position< 100 ms≈ 25 V≈ 15 V
according to DIN VDE 0110-1:04.976 kVIII3 outside, 2 inside500 V AC3.25 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 7 – 5KS 0236/1 KS 0276/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.26 kg–
w
Type Rated voltage Part number Std. Pack
SPW 1004 3 AC 380 – 415 V 50 – 60 Hz R3.183.0040.0 1SPW 1005 3 AC 380 – 415 V 50 – 60 Hz R3.183.0050.0 1
644 Subject to change without further notice
Three-phase – phase sequence relays without auxiliary
supply voltage
• Detection of incorrect phase sequence• Closed-circuit principle• Contact assignment: SAP 1002 1 change-over contact, SAP 1003
2 change-over contacts
Applications
• Monitoring of the phase sequence in systems such as:• Crane and elevator systems• Machines with reversal of rotational direction • Pumps, condensers and compressors• Air conditioning and ventilation systems• Detection of the direction of motion of escalators
Function
The SAP devices monitor their correct phase sequence after phases L1, L2, L3 havebeen applied (clockwise rotation). With a pure ohmic load, a phase failure is alsodetected.
After applying the external line voltages L1, L2 L3 and if the phase sequence iscorrect, the relay will switch into the ON position. If one of the conditions is notfulfilled, the relay will remain in the OFF position. The red LED lights up.
If a phase failure occurs during operation, the relay will switch back into the OFFposition (the red LED lights up), if no voltage feedback occurs through the connectedloads. It is reset automatically after the fault has been eliminated.
The two devices differ in their contact assignments.The SAP 1002 is fitted with one change-over contact, while the SAP 1003 is fitted withtwo change-over contacts.
Circuit diagram
interfaceinterfaceMeasuring and monitoring relays Phase sequence relays SAP 1002, SAP 1003
w
645Subject to change without further notice
interfaceMeasuring and monitoring relays Phase sequence relays SAP 1002, SAP 1003
Application example
Monitoring a system
The SAP 1003 monitors the voltage supply of the system. If a fault occurs due to anincorrect phase sequence or a phase failure, the SAP 1003 will switch into the OFFposition. The contactor K3 switches the system off. The PLC evaluates the messagesystem-specifically.
Function diagram Dimension diagram
System
for DIN rail according to EN 50022Volt. supply LED SUPPLY
Incorrect phase sequence
Phase failure L1* or L2*
Phase failure L3*
LED TRIPPED
15/18 15/18;25/2815/16 15/16;25/26
SAP SAP1002 1003
tA = response valuetR = release value* without feedback
interfaceMeasuring and monitoring relaysPhase-sequence relay SAP 1002, SAP 1003
646 Subject to change without further notice
interface
Technical data
Type of function according to DIN EN 60255-6:11.94
Function control Function diagramPower supply circuit
Rated voltage (UN)Rated consumption at 50 Hz and UN (AC) Rated consumption at 50 Hz and UN (AC) Rated frequency Operating voltage rangeOutput circuit
Contact assignment Contact material Rated operating voltage Un
Max. continuous current In per contact Application category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gG Permissible switching frequency Mechanical life Response time tA
Release time tR
General data
Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Pollution degree Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Conductor cross sections fine-stranded / solid
or fine-stranded with ferrules Permissible tightening torque Weight Accessories Approvals
SAP 100 SAP 1003
Three-phase – phase sequence relays,Closed-circuit principle1 green LED, 1 red LEDFD 0099 W1
380 – 415 V 440 – 480 V
3.9 VA 4.2 VA3.5 W 3.8 W50 – 60 Hz0.8 – 1.15 x UN
1 change-over contact 2 change-over contactsAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles20 ms35 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3 – 2KS 0276/1 KS 0236/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.28 kg–
w
Overview of devices/part numbers
Type Rated voltage Part number Std. Pack
SAP 1002 3 AC 380 – 415 V 50 – 60 Hz R3.183.0080.1 13 AC 440 – 480 V 50 – 60 Hz R3.183.0090.1 1
SAP 1003 3 AC 380 – 415 V 50 – 60 Hz R3.183.0070.1 13 AC 440 – 480 V 50 – 60 Hz R3.183.0100.1 1
647Subject to change without further notice
interfaceMeasuring and monitoring relaysNetwork monitoring relay SUW 3001
Application examples
• Monitoring of three-phase current – undervoltage faults and phase failureof machines or systems, such as:- Machines with reversal of the direction of rotation (cranes, robots, pumps,excavators, conveyor systems, etc.)
- Chemical processes- Test and calibration systems
Three-phase voltage monitor without auxiliary supply voltage
• Undervoltage detection of one, two or all three phases• Adjustable undervoltage detection between 285 and 360 V• Detection of phase failure of one, two or all three phases• Rated three phase voltage 3 AC 400 V without neutral connection and
auxiliary supply voltage• Reaction time 35 ms• Closed-circuit principle• Contact assignment: 2 change-over contacts
Function
The SUW 3001 monitors the external line voltages (its own voltage supply) L1, L2, L3for undervoltage and phase failure. It works without a neutral connection and an auxiliary supply voltage.
After applying the external line voltages L1, L2, L3, the voltages of which exceed thevoltage limit value, the SUW switches into its ON position (closed-circuit principle).The green LED lights up. If the voltage falls below the pre-selected voltage limit value,the relay will switch into its OFF position. The green LED extinguishes.
The rated voltage for three-phase current networks is 3 AC 400 V with a largeoperating voltage range. The setpoint value of the undervoltage can be pre-selected tobetween 285 and 360 V with a potentiometer. If a fault occurs, the relay will switchinto its OFF position with a reaction time of 35 ms. The green LED will extinguishes.After elimination of the fault, the SUW switches automatically into its ON position andthe pre-selected 10 V hysteresis applies. The green LED lights up.
Fault detection occurs at:• Phase failure of one, two or all three phases• Undervoltage detection of one, two or all three phases, related to the adjusted
voltage of 3 AC 285 V to 360 V
Circuit diagram
Setting ranges
The three-phase undervoltage range of 3 AC 285 V to 360 V of all three phases can beadjusted finely with an integrated potentiometer.
L
648 Subject to change without further notice
Application example
Monitoring a system
The SUW 3001 monitors the three-phase current network for a pre-selectedundervoltage or a phase failure in a system. If the SUW 3001 reports a fault, the relayK2 will switch into its OFF position. The system is switched off and the PLC evaluatesthe message system-specifically.
Function diagram Dimension diagram
interfaceinterfaceMeasuring and monitoring relays Network monitoring relay SUW 3001
System
for DIN rail according to EN 50022Supply voltagePhases L1, L2, L3Release value< UResponse value < UMin. value
LED TRIPPED green
15/18;25/2815/16;25/26
tA =response valuetR =release valueHysteresis = response value -
release value
649Subject to change without further notice
interfaceMeasuring and monitoring relays Network monitoring relay SUW 3001
Technical data
Type of function according to DIN EN 60255-6:11.94
Function controlFunction diagramPower supply circuit
Rated voltage UN 3 ACRated consumption at 50 Hz and UN (AC)Rated consumption set to 50 Hz and UN (AC)Rated frequencyOperating voltage rangeMeasuring circuit
Electrical isolation from power supply circuitSettingsSetting range of undervoltage detectionDispersionInfluence of the supply voltageInfluence of the ambient temperatureOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current In per contactApplication category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gGPermissible switching frequencyMechanical lifeResponse time tA
Release time tR
Hysteresis for undervoltage detectionGeneral data
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Noise immunity according to IEC 61000-4Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
SUW 3001
Three-phase voltage monitor without auxiliary supply voltageClosed-circuit principle1 LED greenFD 0134 W1
400 V
3.8 VA3.6 W50 – 60 Hz0.65 – 1.15 x UN
noanalog3 AC 285 to 360 V≤ ± 0.5 %≤ ± 0.02 % / % ∆UN
≤ ± 0.05 % / K∆T
2 change-over contactsAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles≤ 25 ms ± 10 ms depending on the phase position< 100 ms≈ 10 V
according to DIN VDE 0110-1:04.976 kVIII3 outside, 2 inside500 V AC3.25 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 7-5KS 0236/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.26 kg–
L
Overview of devices/part numbers
Type Rated voltage Part number Std. Pack
SUW 3001 3 AC 400 V 50 – 60 Hz R3.184.0030.0 1
interfaceinterface
650 Subject to change without further notice
Measuring and monitoring relays Three-phase network monitor DNU
Description Type Part No. Std. Packwith foot for TS 35 (for installation distributors) DNU-H-400V-250V4A 86.030.6353.0 1with foot for TS 35 + TS 32 DNU-U-400V-250V4A 87.030.6353.0 1
Input data
Rated voltage 230/400 V AC +6%/–10%, 50 – 60 HzPower consumption approx. 4 VANetwork monitoring –Response value 0.85 x UN
ON-delay approx. 500 msOFF-delay approx. 500 msSwitching hysteresis approx. 5 %Network failure detection –Back-up fuse approx. 0.5 AStatus display LED
Output data
Max. switching voltage 250 V AC/DCMax. switching current 4 A AC/DCSwitching capacity (ohmic load)
at 24 V DC, max. 100 Wat 230 V AC, max. 1100 VA
Contact assignment 2 change-over contacts
General data
Ambient temperature –10 °C...+50 °CStorage temperature –40 °C...+85 °CConductor cross section
fine-stranded 0.5 – 2.5 mm2
solid 0.5 – 4 mm2
Device protection 0.5 A
Rail mount on TS 35 only TS 35 or TS 32(86.030.6353.0) (87.030.6353.0)
Dimensions (mm): W x H x D48 x 96 x 60
DNUThree-phase network monitor
Three-phase network monitorfor voltage monitoring of single-phase and three-phasenetworks with neutral conductor.Safe signaling at 85% underflow of the mains voltage.
651Subject to change without further notice
interface
DimensionsCircuit diagram
Connection example
Three-phase network monitor
With TS 35 foot, the relay is49.5 mm deep (rail included)
Measuring and monitoring relays Three-phase network monitor DNU
interfaceinterface
652 Subject to change without further notice
Description Type Part No. Std. Packwith foot for TS 35 (for installation distributors) DSU-400V-250V4A 87.030.6453.0 1
Input data
Rated voltage 230 V AC +6%/–10%, 50 – 60HzPower consumption approx. 4 VANetwork monitoring 3 x 400 V ACResponse value –ON-delay approx. 6 sOFF-delay approx. 250 msSwitching hysteresis –Network failure detection > 900 msBack-up fuse –Status display LED
Output data
Max. switching voltage 250 V ACMax. switching current 4 ASwitching capacity (ohmic load)
at 24 V DC, max. 100 Wat 230 V AC, max. 1000 VA
Contact assignment 1 change-over contact
General data
Ambient temperature –10 °C...+50 °CStorage temperature –40 °C...+85 °CConductor cross section
fine-stranded 0.14 – 2.5 mm2
solid 0.14 – 4 mm2
Device protection –
Rail mount TS 35 or TS 32
Dimensions (mm): W x H x D48 x 96 x 60
DSUThree-phase safety monitor
Measuring and monitoring relaysThree-phase safety monitor DSU
Three-phase safety monitordesigned for monitoring the supply lines ofAC motors (380 V/220 V~, 50 – 60 Hz)
653Subject to change without further notice
interfaceThree-phase safety monitor
DimensionsCircuit diagram
Measuring and monitoring relays Three-phase safety monitor DSU
Connection example
L1L2L3N
F
K
HM3~
L1 L2 L3
L1 N 1.1 1.4 1.2
interfaceinterface
654 Subject to change without further notice
Description Type Part No. Std. PackDRA-400V-250V3A 81.010.1000.0 1
Input data
Rated voltage 3 x 400 V AC +6%/–10%, 50 HzPower consumption approx. 2.5 VADropout voltage ≤ 3 x 100 V AC / 50 HzON-delay < 25 msOFF-delay < 30 ms
Relay switching logicclockwise rotation relay picked upcounterclockwise rotation relay released
Output data
Max. switching voltage 250 V ACMax. switching current 3 A AC / DCSwitching capacity (ohmic load)
at 24 V DC, max. 70 Wat 250 V AC, max. 750 VA
Contact assignment 2 change-over contacts
General data
ON-delay < 25 msOFF-delay < 30 msContact material AgNiLife span:
mechanical 2 x 107 cycleselectrical 1 x 105 cycles at full load
Test voltage input/output 2 kVeff
Ambient temperature 0 °C...+40 °CStorage temperature –40 °C...+85 °CConductor cross section
fine-stranded 0.5 – 2.5 mm2
solid 0.5 – 4 mm2
Rail mount TS 35 or TS 32
Dimensions (mm): W x H x D48 x 96 x 63
DRARotation direction indicator
Measuring and monitoring relaysRotation direction indicator DRA
Rotation direction indicator DRAfor monitoring the phase sequence of AC motors
655Subject to change without further notice
interfaceRotation direction indicator
DimensionsCircuit diagram
Measuring and monitoring relaysRotation direction indicator DRA
656 Subject to change without further notice
Underload detection of electric motors without additional sensor
• Three-phase and single-phase network• Adjustable start-up override time• With or without fault memory• Open-circuit or closed-circuit principle• SBW 1004 with open-circuit principle• SBW 1005 with closed-circuit principle
Applications
• Machine tools:Protection of the motors against underload, for example by- detection of tool destruction and tool wear- optimization of cutting forces and tool feed- forward and reverse control of thread cutting machines
• Pressure optimization on rolls and presses• Regulation of conveyance quantities and drive forces on conveyor and transport
equipment• Monitoring the slip and destruction of V belts• Monitoring the motion of rolling doors• Idle monitoring and regulating the conveyance quantity of pumps• Regulating the amount of air conveyed in air conditioning systems• Checking the motion and wear of the wash brushes in
large washing systems for cars, trucks, buses, railroads• Controlling the consistency of agitated material in agitators
Circuit diagram
Note
Functions
SBW 1004 – open-circuit principle
When the motor is switched on, the adjustable start-up override time on the relaybegins. After this time has elapsed, the SBW 1004 monitors the pre-selected phaseshift cos ϕ (in °). When the load falls, the phase shift becomes larger – cos ϕ becomes smaller. If the pre-selected phase shift is exceeded, the relay willswitch into its ON position after expiration of the pre-selected response time. If thephase shift falls below the pre-selected value – back to a normal load – the relay willswitch into OFF position after expiration of the pre-selected release time. The pre-selected response and release times (1000 ms) prevent the relay from respondingduring brief deviations from the setpoint value.
SBW 1005 – closed-circuit principle
When supply voltage is applied, the relay switches into the ON position.When the motor is switched on, the adjustable start-up override time on the relaybegins. After this time has elapsed, the SBW 1005 monitors the pre-selected phaseshift cos ϕ (in °). When the load falls, the phase shift increases – cos ϕ decreases. Ifthe pre-selected phase shift is exceeded, the relay will switch into its OFF positionafter expiration of the pre-selected response time. If the phase shift falls below thepre-selected value – back to a normal load – the relay will switch into the ON positionafter expiration of the pre-selected release time. The pre-selected response andrelease times (1000 ms) prevent the relay from responding during brief deviationsfrom the setpoint value.
SBW 1004/SBW 1005 – with fault memory
The fault memory is put into operation by shunting the terminals Y1, Y2. If the phaseshift falls below the pre-selected value – back to normal load – the relay will remain inthe ON/OFF position. The fault memory is cleared only by being reset; the relayswitches into the OFF/ON position. If the pre-selected phase shift is still exceeded,the relay will switch into the OFF/ON position only during the resetting.
Accessories
Cover Z 29
interfaceinterfaceMeasuring and monitoring relays Load monitor motor – cos phi SBW 1004, SBW 1005
• Short-circuit the transformer before
disconnecting the relay.
• If the rated motor current is higher than
5 A, a current transformer must be used.
The current transformer must be designed
for a load of RI + 2 x RL.
• Terminals k and L1 must always be at the
same phase. Maintain the clockwise
direction of rotation for terminals
L1, L2, L3.
RL = line resistance
RI = internal resistance
w
657Subject to change without further notice
interfaceMeasuring and monitoring relays Load monitor motor – cos phi SBW 1004, SBW 1005
Application examples Monitoring a conveyor belt
The load monitor SBW 1004 controls the conveyance quantity. If too little material issupplied – falling load – the relay will switch into its ON position after expiration of thepre-selected response time.
Monitoring dust filters
The load monitor SBW 1005 monitors the filter for contamination. If the filter iscontaminated, the motor load falls – cos ϕ becomes smaller. If the pre-selected phaseshift is exceeded, the relay will switch into its OFF position after expiration of the pre-selected response time – closed-circuit principle. The fault is stored until the reset keyis operated manually.
Function diagrams
Principle
With an inductive load, the current lags behind the voltage by phase angle ϕ. If the load on the motor falls, the phase angle becomes larger and subsequently cos ϕbecomes smaller. This change of phase angle is a precise measure of the load changeat the motor shaft. The load monitor monitors the phase shift between the voltageand the current under inductive loads in a sinusoidal single-phase and three-phasenetwork. (Not suitable for phase control and frequency-controlled motors).
Dimension diagram
Inductive load
for DIN rail according to EN 50022
Current
Voltage
Phaseanglein degrees
P = effective powerQ = reactive powerS = apparent power Shift = cos ϕ = 0.5
Pab = U · I · cos ϕ · ηη = Efficiency of the motor
Supply voltage
LED SUPPLY green
Load current
> Adjustedphase shift
Fault memory at terminal Y1/Y2
Reset (reset key)
LED TRIPPED red
15/1815/16
Supply voltage
LED SUPPLY green
Load current
> Adjustedphase shift
Fault memory at terminal Y1/Y2
Reset (reset key)
LED TRIPPED red
15/1815/16
tAM = Motor start-up time
tAN = response time
tR = release time
Rated motor current 0.1 to 5 AThree-phase network, e.g. 3 AC 400 VRated device voltage 3 AC 400 V
Rated motor current > 5 ASingle-phase network, e.g. 230 VRated device voltage 3 AC 230 V
Memory
Outlet air
Intake air
Dust filter
interfaceMeasuring and monitoring relays Load monitor motor – cos phi SBW 1004, SBW 1005
658 Subject to change without further notice
interface
Technical data
Type of function according to DIN EN 60255-6:11.94
Function control Function diagramPower supply circuit
Rated voltage (UN) 3 ACRated consumption at 50 Hz and UN (AC) Rated consumption at 50 Hz and UN (AC) Rated frequency Operating voltage rangeMeasuring circuit
Settings Start-up override time Average value of the fault Dispersion Influence of the supply voltage Influence of the ambient temperature Phase shift (cos ϕ) Dispersion Influence of the supply voltage Influence of the ambient temperature Hysteresis Rated motor current
Permissible continuous current Start-up peak current Current threshold Fault memoryOutput circuit
Contact assignment Contact material Rated operating voltage Un
Max. continuous current In per contact Application category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gG Permissible switching frequency Mechanical life Response time tA
Release time tR
General information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Conductor cross sections fine-stranded / solid
or fine-stranded with ferrules Permissible tightening torque Weight Accessories Approvals
SBW 1004 SBW 1005
Load monitor; Load monitor;< cos ϕ responding < cos ϕ respondingwith/without fault memory, with/without fault memory,Open-circuit principle Closed-circuit principle1 green LED, 1 red LED 1 green LED, 1 red LEDFD 0072 W1 FD 0072 W1
380 – 415 V 440 – 480 V
3.4 VA 3.4 VA2.9 W50 – 60 Hz0.8 – 1.1 x UN
analog 1.5 – 30 s< 15 % of the end value≤ ± 0.5 %≤ ± 0.02 % / % ∆UN
≤ ± 0.025 % / K∆T≤ 18° – < 90°≤ ± 0.5 %≤ ± 0.05 % / % ∆UN
≤ ± 0.1 % / K∆T≤ 2°0.1 – 5 A(with > 5 A an additional transformer is required; load ≤ 50 mΩ)≤ 6 A≤ 25 A, max. 3 s0.005 AActivation by shunting terminals Y1/Y2
1 change-over contactAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 4000 switching cycles/h20 x 106 switching cycles1000 ms1000 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3-4KS 0231/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.27 kgCover Z 29
wOverview of devices/Part numbers
Type Rated voltage Part number Std. Pack
SBW 1004 3 AC 380-415 V 50 – 60 Hz R3.185.0120.1 1SBW 1005 3 AC 380-415 V 50 – 60 Hz R3.185.0020.1 1
3 AC 440-480 V 50 – 60 Hz R3.185.0310.1 1
659Subject to change without further notice
interfaceMeasuring and monitoring relays Load monitor motor – cos phi SBW 1007
Overload detection of electric motors without additional sensor
• Three-phase and single-phase network• Adjustable start-up override time • With or without fault memory• Closed-circuit principle
Applications
• Machine tools:Protection of the motors against underload, for example by- detection of tool destruction and tool wear- optimization of cutting forces and tool feed- forward and reverse control of thread cutting machines
• Pressure optimization on rolls and presses• Regulation of conveyance quantities and drive forces on conveyor and transport
equipment• Monitoring the slip and destruction of V belts• Monitoring the motion of rolling doors• Idle monitoring and regulating the conveyance quantity of pumps• Regulating the amount of air conveyed in air conditioning systems• Checking the motion and wear of the wash brushes in large washing systems for
cars, trucks, buses, railroad• Controlling the consistency of agitated material in agitators
Circuit diagram
Functions of the closed-circuit principle
When supply voltage is applied, the relay switches into the ON position.When the motor is switched on, the adjustable start-up override time on the relaybegins. After this time has elapsed, the SBW 1007 monitors the pre-selected phaseshift cos ϕ (in °). When the load falls, the phase shift becomes smaller – cos ϕbecomes larger. If the value falls below the pre-selected phase shift, the relay willswitch into its OFF position after expiration of the pre-selected response time. If thepre-selected phase shift is exceeded – back to a normal load – the relay will switchinto the ON position after expiration of the pre-selected release time. The pre-selectedresponse and release times (1000 ms) prevent the relay from responding during briefdeviations from the setpoint value.
Fault memory
The fault memory is put into operation by shunting the terminals Y1, Y2.If the phase shift falls below the pre-selected phase shift – back to normal load – therelay will remain in the ON/OFF position. The fault memory is cleared only by beingreset; the relay switches into the OFF/ON position.If the pre-selected phase shift is still exceeded, the relay will switch into the OFF/ONposition only during the reset.
Note
• Short-circuit the transformer before
disconnecting the relay.
• If the rated motor current is higher than
5 A, a current transformer must be used.
The current transformer must be
designed for a load of RI + 2 x RL.
• Terminals k and L1 must always be at the
same phase. Maintain the clockwise
direction of rotation for terminals
L1, L2, L3.
RL = line resistance
RI = internal resistance
w
660 Subject to change without further notice
Application examples
Monitoring of rolls
The load monitor SBW 1007 monitors the roll contact pressure. If the roll contactpressure rises, the motor load also rises (cos ϕ becomes larger). If the phase shift fallsbelow the pre-selected value, the relay will switch into its OFF position (closed-circuitprinciple).
Monitoring a crusher
The load monitor monitors the stone crusher for overload. If the phase shift falls belowthe pre-selected value as the motor load rises (e.g. through jamming), the load monitorwill switch. The fault is stored until the reset key is operated.
Dimension drawing
interfaceinterfaceMeasuring and monitoring relays Load monitor motor – cos phi SBW 1007
Principle
With an inductive load, the current lags behind the voltage by phase angle ψ.If the load on the motor falls, the phase angle becomes larger and subsequentlycos ϕ becomes smaller. This change of phase angle is a precise measure of the loadchange at the motor shaft. The load monitor monitors the phase shift between thevoltage and the current under inductive loads in a sinusoidal single-phase and three-phase network. (Not suitable for phase control and frequency-controlled motors).
Inductive load
Rated motor current 0.1 to 5 AThree-phase network, e.g. 230 VRated device voltage 3 AC 230 V
Rated motor current > 5 ASingle-phase network, e.g. 3 AC 400 VRated device voltage 3 AC 400 V
Memory
Memory
for DIN rail according to EN 50022Current
Voltage
Phaseanglein degrees
P = effective powerQ = reactive powerS = apparent power Shift = cos ϕ = 0.5
Pab = U · I · cos ϕ · ηη = Efficiency of the motor
661Subject to change without further notice
interfaceMeasuring and monitoring relays Load monitor motor – cos phi SBW 1007
Technical data
Type of function according to DIN EN 60255-6:11.94
Function controlFunction diagramPower supply circuit
Rated voltage UN 3 ACRated consumption set to 50 Hz and UN (AC)Rated consumption set to 50 Hz and UN (AC)Rated frequencyOperating voltage rangeMeasuring circuit
SettingsStart-up override time Mean value of the faultDispersionInfluence of the supply voltageInfluence of the ambient temperaturePhase shift (cos ϕ)DispersionInfluence of the supply voltageInfluence of the ambient temperatureHysteresisRated motor current
Permissible continuous currentStart-up peak currentCurrent thresholdFault memoryOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current In per contactApplication category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gGPermissible switching frequencyMechanical lifeResponse time tA
Release time tR
General information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Noise immunity according to IEC 61000-4Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
Overview of the devices/Part numbers
SBW 1007
Load monitor;< cos ϕ respondingwith/without fault memory,Closed-circuit principle1 green LED, 1 red LEDFD 0116 W1
380 – 415 V
3.4 VA2.9 W50 – 60 Hz0.8 – 1.1 x UN
analog1.5 – 30 s< 15 % of the end value≤ ± 0.5 %≤ ± 0.02 % / % ∆UN
≤ ± 0.025 % / K∆T≤ 18° – < 90°≤ ± 0.5 %≤ ± 0.05 % / % ∆UN
≤ ± 0.1 % / K∆T≤ 2°0.1 – 5 A(with > 5 A an additional transformer is required; load ≤ 50 mΩ)≤ 6 A≤ 25 A, max. 3 s0.005 AActivation by shunting terminals Y1/Y2
1 change-over contactAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 4000 switching cycles/h20 x 106 switching cycles1000 ms1000 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3-4KS 0231/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.27 kgCover Z 29
w
Type Rated voltage Part number Std. Pack
SBW 1007 3 AC 380 – 415 V 50 – 60 Hz R3.185.0190.1 1
662 Subject to change without further notice
Motor protection relays/temperature monitors for PTC connection
• 1 monitoring circuit for PTC thermistor according to DIN EN 60947-8• Monitoring for damage or short circuit of the sensor cable• Closed-circuit principle• SMS 1002: without fault memory, contact assignment 1 change-over
contact• SMS 1005: with fault memory, reset key or resetting
through the supply voltage, contact assignment 2 change-over contacts
Applications
• Motor protection through monitoring of the temperature in the motor windingIncreased winding temperatures caused by:Phase imbalance, phase failure, high-torque starting,excessive ambient temperature – insufficient cooling,Overvoltage or undervoltage, high switching frequency
• Temperature monitoring of coolants in power transformers
Note
• The supply voltage is electrically isolated from the measuring circuit(exception: DC 24 V).
Circuit diagram
Functions
SMS 1002
After applying the supply voltage (A1/A2) and connection of the PTC thermistor (T1/T2), the relay switches into the ON position. It operates accordingto the closed-circuit principle and ensures safe switch-back into the OFFposition in case of the following malfunctions:• Due to the increasing temperature, the PTC thermistor exceeds a resistance value in
the range ≥ 2500 Ω to ≤ 3600 Ω (when the temperature decreases and the PTCthermistor’s resistance value ranges between ≤ 1500 Ω and ≥ 1000 Ω, the relay willswitch back into the ON position)
• The sensor circuit falls below a resistance value of < 20 Ω in case of short circuit• Damage to the cables• Power failureThe fault is indicated when the LED TRIPPED lights up. The fault is not stored.SMS 1005
The basic function corresponds to that of the SMS 1002. An additional fault memoryprevents the relay from switching back into the ON position after elimination of thefault. The fault memory can be cleared by operating the reset key only if the fault hasbeen eliminated. The SMS 1005 will be ready for another fault identification only if thefault memory has been cleared or the supply voltage has been switched off for at least250 ms.
Dimension diagram
interfaceinterfaceMeasuring and monitoring relays Motor temperature monitors SMS 1002, SMS 1002-101, SMS 1005
for DIN rail according to EN 50022
w
663Subject to change without further notice
interfaceMeasuring and monitoring relays Motor temperature monitors SMS 1002, SMS 1002-101, SMS 1005
Monitoring of oil temperature
If the oil temperature in the transformer rises above the rated operating temperature(TNF), the relay will switch into the OFF position. The horn H1 signals the overheating.Temperature adjustments can be fed through the PLC. The fault memory of the SMS1005 prevents the relay from switching back into the ON position after the fault hasbeen eliminated. The fault memory can only be cleared after the reset key is pressedor the supply voltage is switched off for at least 250 ms.
Switching range / Resistance curve
Sensor
PTC thermistors (temperature sensors) are resistances with very high positiveresistance temperature coefficients. (PTC = positive temperature coefficient). Theyare installed in the outlet air side of the stator end winding of those motors for whichthe temperature diagram is known prior to manufacturing. Their rated operatingtemperature (TNF) depends on the motor type. When the rated operating temperatureis exceeded, the resistance value of the PTC thermistors will increase abruptly. If thissensor is connected to a motor protection relay/temperature monitor, the abruptincrease in the resistance value will cause the relay to switch.
Application examples
Motor monitoring
If the motor temperature exceeds the rated operating temperature (TNF) of thePTC thermistor temperature sensor, or if cable damage/short circuit occurson the sensor, the motor is switched off via K1.
Function diagram
Remotereset
Supply voltage
LED SUPPLY greenDamage to the cablehigh-resistance
PTC thermistor
low-resistanceshort circuit
LED TRIPPED red
11/1411/12
Supply voltage
LED SUPPLY greenDamage to the cablehigh-resistance
PTC thermistor
low-resistanceshort circuit
Reset
LED TRIPPED red
11/14; 21/2411/12; 21/22
t1 =switch-off time must be >than min. switch-off time
PTC thermistor
Curve (type A)according to DINVDE 0660 part 303
Relay releases
Relay picks up
Relay releases
*Relay stays released
TNF = rated operating temperature
-20 0 TNF-20 ˚CTNF-5 ˚CTNF TNF+5˚CTNF+15 ˚C
interfaceMeasuring and monitoring relays Motor temperature monitors SMS 1002, SMS 1002-101, SMS 1005
664 Subject to change without further notice
interface
Technical data
Function type
Function control Function diagramPower supply circuit
Rated voltage UN AC
DCRated consumption at 50 Hz and UN (AC) Rated consumption UN (DC) Rated frequency Operating voltage rangeMeasuring circuit
Electrical isolation Relay releases Relay picks up Relay releases Sum of sensors’ cold resistance Voltage in case of damage to the sensor cable Current in case of short circuit of the sensor cableOutput circuit
Contact assignment Contact material Rated operating voltage Un
Max. continuous current In per contact Application category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gG Permissible switching frequency Mechanical life Response time tA
Release time tR
General data
Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Pollution degree Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Conductor cross sections fine-stranded / solid
or fine-stranded with ferrules Permissible tightening torque Weight Accessories Approvals
SMS 1002 SMS 1002-101 SMS 1005
Motor protection relay/ Motor protection relay/ Motor protection relay/temperature monitor for temperature monitor for temperature monitor for PTC thermistor connection PTC thermistor connection PTC thermistor connectionaccording to EN 60947-8 according to EN 60947-8 according to DIN EN 60947-8Closed-circuit principle Closed-circuit principle Fault memory,
reset through supplyvoltage,Closed-circuit principle
1 green LED, 1 red LED 1 green LED, 1 red LED 1 green LED, 1 red LEDFD 0088 W1 FD 0088 W1
FD 0089 W124 V 110 – 220 – 220 – 240 V
127 V 240 V
24V
3.0 VA 3.0 VA 3.0 VA 3.0 VA2.0 W
50 – 60 Hz0.8 – 1.1 x UN
yes no yes≥ 2500 Ω – ≤ 3600 Ω with increasing sensor temperature≤ 1500 Ω – ≥ 1000 Ω with decreasing sensor temperaturewith short circuit on the sensor line ≤ 20 Ω≤ 1500 ΩDC 10 V2.5 mA
1 change-over contact 1 change-over contact 2 change-over contactsAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles< 20 ms< 20 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3 – 2KS 0140/2 KS 0140/2 KS 0157/22 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.24 kg–
w
Overview of devices/part numbers
Type Rated voltage Part number Std. Pack
SMS 1002 AC 24 V 50 – 60 Hz R3.186.0110.3 1AC 110 – 127 V 50 – 60 Hz R3.186.0040.3 1AC 220 – 240 V 50 – 60 Hz R3.186.0020.3 1
SMS 1002-101 DC 24 V R3.186.0070.3 1SMS 1005 AC 220 – 240 V 50 – 60 Hz R3.186.0010.2 1
665Subject to change without further notice
interfaceMeasuring and monitoring relay Motor temperature monitor SMS 1006
Motor protection relay/temperature monitor for PTC connection
with restart lockout
• 1 monitoring circuit for PTC thermistor according to DIN EN 60947-8• Fault memory with reset key; no reset through supply voltage• With restart lockout• Monitoring for damage or short circuit of the sensor cable• Closed-circuit principle• Contact assignment 2 change-over contacts
Dimension diagram
Note
• The supply voltage is electrically isolated from the measuring circuit.
Circuit diagram
Applications
• Motor protection through monitoring of the temperature in the motor windingIncreased winding temperatures caused by:Phase imbalance, phase failure, high-torque starting,excessive ambient temperature – insufficient cooling,Overvoltage or undervoltage, high switching frequency
• Temperature monitoring of coolants in power transformers
Function
After applying the supply voltage (A1/A2) and connection of the PTC thermistor(T1/T2), the relay switches into the ON position. It operates according to the closed-circuit principle and ensures safe switch-back into the OFF position in case of thefollowing malfunctions:• Due to increasing temperature, the PTC thermistor exceeds a resistance value in
the range ≥ 2500 W to ≤ 3600 W (when the temperature decreases, the PTCthermistor’s resistance value ranges between ≤ 1500 W and ≥ 1000 W, andpressing the reset key, the relay will switch into the ON position.
• The sensor circuit falls below a resistance value of < 20 Ω in case of short circuit• Damage to the cables• Power failureThe fault is indicated when the LED TRIPPED lights up.
A fault memory with restart lockout (no resetting through the supply voltage)prevents the relay from switching back into the ON position after the fault has beeneliminated. The fault memory can be cleared by operating the reset key only if thefault has been eliminated.The SMS 1006 will be ready for another fault identification only after the fault memoryhas been cleared and the supply voltage has been applied.Contact assignment: 2 change-over contacts
for DIN rail according to EN 50022
w
666 Subject to change without further notice
Monitoring transformer temperature
When the rated voltage temperature (TNF) is exceeded, the relay switches into theOFF position and the transformer is switched off. Also if there is a failure in the supplyvoltage of the relay, the transformer stays switched off. The fault memory with restartlockout prevents the transformer from restarting automatically when the supplyvoltage is switched on again or when the fault has been eliminated. The relayswitches back into the ON position only after resetting.
Switching ranges / resistance curve
interfaceinterfaceMeasuring and monitoring relays Motor temperature monitor SMS 1006
Applications
Monitoring cooling water
When the cooling water overheats, the relay switches into the OFF position and thesystem is put out of order. Also if there is a failure in the supply voltage of the relay,the system switches off (closed-circuit principle). The fault memory with restartlockout prevents the system from restarting automatically when the supply voltage isswitched on again or when the fault has been eliminated. For a restart, the relay mustbe switched back into the ON position (reset).
Function diagram
Sensor
PTC thermistors (temperature sensors) are resistances with very high positiveresistance temperature coefficients. (PTC = positive temperature coefficient). They areinstalled in the outlet air side of the stator end winding of those motors for which thetemperature diagram is known prior to manufacturing. Their rated operatingtemperature (TNF) depends on the motor type. When the rated operating temperatureis exceeded, the resistance value of the PTC thermistors will increase abruptly. If thissensor is connected to a motor protection relay/temperature monitor, the abruptincrease in the resistance value will cause the relay to switch.
Cooling water
H 3Fault
Supply voltage
LED SUPPLY greenDamage to the cablehigh-resistance
PTC thermistor
low-resistanceshort circuitReset
LED TRIPPED red
11/14; 21/2411/12; 21/22
PTC thermistor
Curve (type A)according to DINVDE 0660 part 303
Relay releases
Relay picks up
Relay releases
*Relay stays released
-20 0 TNF-20 ˚CTNF-5 ˚CTNF TNF+5˚CTNF+15 ˚C
TNF = rated operating temperature
PLC
667Subject to change without further notice
interfaceMeasuring and monitoring relays Motor temperature monitor SMS 1006
SMS 1006
Motor protection relay/temperature monitor according to DIN EN 60947-8,fault memory; no resetting through the supply voltage;closed-circuit principle1 green LED, 1 red LEDFD 0087 W1
220 – 240 V
3.0 VA50 – 60 Hz0.8 – 1.1 UN
yes≥ 2500 Ω – ≤ 3600 Ω with increasing sensor temperature≤ 1500 Ω – ≥ 1000 Ω with decreasing sensor temperaturewith short circuit on the sensor line ≤ 20 Ω≤ 1500 ΩDC 10 V2.5 mA
2 change-over contactsAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles< 20 ms< 20 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3 – 2KS 0157/22 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.26 kg–
w
Type Rated voltage Part number Std. Pack
SMS 1006 AC 220 – 240 V 50 – 60 Hz R3.186.0030.0 1
Technical data
Function type
Function controlFunction diagramPower supply circuit
Rated voltage UN ACRated consumption set to 50 Hz and UN (AC)Rated frequencyOperating voltage rangeMeasuring circuit
Electrical isolationRelay releasesRelay picks upRelay releasesSum of cold resistance of the sensorsVoltage in case of damage to the sensor cableCurrent in case of short circuit of the sensor cableOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current In per contactApplication category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gGPermissible switching frequencyMechanical lifeResponse time tA
Release time tR
General information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Noise immunity according to IEC 61000-4Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
Overview of devices/part numbers
668 Subject to change without further notice
Temperature monitor for thermal resistance Pt 100
• Temperature setting range 0 to +799 °C• Adjustable hysteresis• Digital limit value setting• Monitoring for damage or short circuit of the sensor cable• Compensation of sensor linearity errors• STW 1101 with open-circuit principle• STW 1102 with closed-circuit principle
Applications
• Monitoring of etching solutions• Temperature monitoring of baking lines• Monitoring of chemical processes• Monitoring of intake and outlet air temperature in air conditioning systems• Protection against overtemperature• Protection against undertemperature
Function
The digitally pre-selected limit value is compared with the measured temperaturevalue.If the measured temperature value exceeds the limit value, and if there is no damageor short circuit to the sensor cable, the temperature monitor will switch.The >∂ LED lights up. If the measured temperature value falls below the pre-selectedhysteresis, the STW will switch back into its initial position. Supply voltage,overtemperature, and damage or short circuit of the sensor cable are displayedthrough the SUPPLY LED or TRIPPED LED. The rated voltage is electricallyisolated from the measuring circuit.
STW 1101: Open-circuit principleSTW 1102: Closed-circuit principle
Note
• The supply voltage is electrically isolated from the measuring circuit.
Setting range
Temperature: 0 to + 799 °C digitalHysteresis: 0.2 to ≥ 10 % analog
Circuit diagram
Accessories
Cover Z 29
Pt 100 temperature sensor
Pt 100 sensor according to DIN 43 760, DIN IEC 751Additional technical information can be provided by the sensor supplier.
interfaceinterfaceMeasuring and monitoring relays Temperature monitor for thermal resistance Pt 100 STW 1101, STW 1102
669Subject to change without further notice
interfaceMeasuring and monitoring relays Temperature monitor for thermal resistance Pt 100 STW 1101, STW 1102
Three types of connections are normally usedfor Pt 100 temperature sensors. Thetemperature monitors STW 1101 and STW1102 are connected according to the 3-wiretechnology (principle diagram). The constantcurrent IK will then flow through thetemperature sensor. In order to halve themeasurement errors through the lineresistances RL1 and RL2, a third conductor isused as a measuring conductor. Theresistance of the measuring conductor RLMcan be disregarded due to the high internalresistance of the temperature monitor.
NiCr-Ni Pt 100
Measuring range very large average to largeSetting time short longerAccuracy average preciseDimensions miniature to small smallApplication For measurements in very For measurements in
large measuring ranges medium to largewith high need of accuracy measuring ranges with
high accuracySuitability for measurements very good goodin liquidsSuitability for measurements good to very good poorin gases (e.g. air temperature)Costs (at same low-cost sensors prices higher than that formechan. design) thermocouple sensors
Application examples
Monitoring of chemical processes
The Pt 100 temperature sensor monitors the temperature of the liquid.If the temperature rises above the pre-selected limit value, the PLC is triggeredthrough the terminal 15/16 and the valve is closed.
Dimension diagram
3-wire connection
Application examples
Air conditioning system
The intake air temperature of the air conditioning system is monitored with the Pt 100sensor. If the temperature rises above the pre-selected limit value, the STW 1102 willswitch. A fault signal is triggered through the terminal 15/18.
Function diagrams
Properties of the measuring sensors
Measuring sensorPt 100
Measuring sensorPt 100
Faultindicator
Faultindicator
for DIN rail according to EN 50022
Supply voltage
LED SUPPLYDamage to the cableResponse value measured valueRelease valueshort circuit
LED TRIPPED
LED > υ
15/1815/16
Supply voltage
LED SUPPLYDamage to the cableResponse value measured valueRelease valueshort circuit
LED TRIPPED
LED > υ
15/1815/16
Adjustable hysteresis = response value – release value
Adjustable hysteresis = response value – release value
RL1/RL2 = line resistanceRLM = resistance
of the measuringconductor
IK = constant current
PLC
interfaceMeasuring and monitoring relays Temperature monitor for thermal resistance Pt 100 STW 1101, STW 1102
670 Subject to change without further notice
interface
Technical data
Type of function according to DIN EN 60255-6:11.94
Function control Function diagramPower supply circuit
Rated voltage UN ACRated consumption at 50 Hz and UN (AC) Rated consumption at 50 Hz and UN (AC) Rated frequency Operating voltage rangeMeasuring circuit
Electrical isolation Limit value setting Switching hysteresis Hysteresis set with reference to the pre-selected limit value Mean value of the fault Dispersion Influence of the supply voltage Influence of the ambient temperatureOutput circuit
Contact assignment Contact material Rated operating voltage Un
Max. continuous current In per contact Application category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gG Permissible switching frequency Mechanical life Response time tA
Release time tR
General information
Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Pollution degree Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Conductor cross sections fine-stranded / solid
or fine-stranded with ferrules Permissible tightening torque Weight Accessories Approvals
STW 1101 STW 1102
Monitoring of the limit temperature value Monitoring of the limit temperature valuefor Pt 100/.../3 according to DIN IEC 751. for Pt 100/.../3 according to DIN IEC 751.Linearity error is compensated. Linearity error is compensated.Adjustable limit value and hysteresis. Adjustable limit value and hysteresis.Monitoring of the sensor line for Monitoring of the sensor line for damage and short circuit. damage and short circuit.Open-circuit principle, Closed-circuit principle,temperature transgression temperature transgression1 LED green, 2 LEDs red 1 LED green, 2 LEDs redFD 0113 W1 FD 0114 W1
220 – 240 V
3.3 VA2.5 W50 – 60 Hz0.8 – 1.1 x UN
yes0 – +799, digitalapprox. 0.5 K0.2 % to ≥ 10 %, analog± 1.5 % ± 1 Digit± 1 %≤ ± 0.02 % / % ∆UN
≤ ± 0.01 % / K∆T
1 change-over contactAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles50 ms50 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3 – 18KS 0304/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.29 kgCover Z 29–
Overview of devices/part numbers
Type Rated voltage Part number Std. Pack
STW 1101 AC 220-240 V 50-60 Hz R3.187.0030.0 1STW 1102 AC 220-240 V 50-60 Hz R3.187.0040.0 1
671Subject to change without further notice
interfaceMeasuring and monitoring relaysTemperature monitor for thermocouple NiCr-Ni STW 1001, STW 1002
Temperature monitor for thermocouple NiCr-Ni
• Temperature setting range 0 to + 999 °C• Adjustable hysteresis• Digital limit value setting• Reference junction temperature +25 °C• Monitoring for damage or the sensor cable• STW 1001 with open-circuit principle• STW 1002 with closed-circuit principle
Applications
• Monitoring of etching solutions• Temperature monitoring of baking lines• Monitoring of chemical processes• Monitoring of intake and outlet air temperature in air conditioning systems• Protection against overtemperature
Function
The digitally pre-selected limit value is compared with the measured value of the NiCr-Ni temperature sensor. If the measured value exceeds the limit value, and if there isno damage in the sensor cable, the temperature monitor will switch. The >∂ LEDlights up. If the measured temperature value falls below the pre-selected hysteresis,the STW will switch back into its initial position. Supply voltage, overtemperature, anddamage or short circuit of the sensor cable are displayed through the SUPPLY LED orBREAK LED. The rated voltage is electrically isolated from the measuring circuit. STW1001: Open-circuit principle STW 1002: closed-circuit principle.
Setting range
Temperature: 0 to + 999 °C digital hysteresis: 0.2 to ≥ 10 % analog
NiCr-Ni temperature sensor
NiCr-Ni sensor according to DIN 43710 IEC 584 sec. 1 type K
The temperature difference between the measuring point and the reference junctiongenerates a thermal voltage between the two elements. This is evaluated by theSTW. The equalizing conductors are used as an extension of the thermocouples(principle diagram). They are installed from the connection of the thermocouple to thereference junction (equalizing box, measuring point selector).
The equalizing conductors consist of a positive and a negative conductor. They havethe same thermoelectrical properties as the thermocouple up to +200 °C. For thisreason, no thermal voltages occur at the connection points. The highest temperaturefor the equalizing conductors is + 200 °C, regardless of the insulation material used. Ifthe temperature at the connection point is higher, a thermal conductor must be usedinstead of an equalizing conductor in order to achieve greater measurement accuracy.Equalizing conductors are less expensive than thermal conductors. Normally theyhave a larger cross section and a lower electrical resistance. From the economic pointof view they are better suited for long lines.
Circuit diagram
Note
• The supply voltage is electrically isolated from the measuring circuit.(exception: DC 24 V).
Accessories
Cover Z 29
NiCr-Ni Pt 100
Measuring range very large average to largeSetting time short longerAccuracy average preciseDimensions micro to small smallApplication For measurements of For measurements of
large meas. ranges average to largewith average need of meas. ranges withaccuracy great accuracy
Performance for measurement very good goodin liquidsPerformance for measurement good to very good averageof gases (e.g. air temperature)Costs (for similar low-cost sensors Price is higher than mechanical design) for thermocouple sensors
672 Subject to change without further notice
Application examples
Temperature monitoring in galvanic processes
The temperature in the galvanic process is monitored with the NiCr-Ni thermocouple.If the temperature rises to a dangerous value (over the set limit value), the heating isswitched off through the break contact 25/28. At the same time the fault indicatorlamp is switched on (contact 15/16).
Dimension diagram
Principle diagram
interfaceinterfaceMeasuring and monitoring relays Temperature monitor for thermocouple NiCr-Ni STW 1001, STW 1002
Application examples
Temperature monitoring for baking installations
The temperature in the baking installation is monitored with the NiCr-Ni thermocouple.If the set temperature limit value is exceeded (because the temperature regulationfailed due to the PLC), the STW will switch off the oven. At the same time a faultsignal is sent out through the second change-over contact.
Function diagrams
Properties of the measuring sensors
Measuring sensorNiCr-Ni
Measuring sensorNiCr-Ni
Disconnection
Referencejunction
Referencejunction
Heating
Faultindicator
Faultindicator
for DIN rail according to EN 50022
NiCr-Ni temperature sensor
Equalizing conductors
Copper conductorsThermocouple
Meas. point
Ni
Process
Terminal blockυK = + 25 °CReference junction
Supply voltage
LED SUPPLY
Response valuemeasured valueRelease value
Damage to the cable
LED TRIPPED
LED > υ15/18; 25/2815/16; 25/26
Supply voltage
LED SUPPLY
Response valuemeasured valueRelease value
Damage to the cable
LED TRIPPED
LED > υ15/18; 25/2815/16; 25/26
Adjustable hysteresis = response value – release value
Adjustable hysteresis = response value – release value
PLC
673Subject to change without further notice
interfaceMeasuring and monitoring relaysThermocouples NiCr-Ni STW 1001, STW 1002
Technical data
Type of function according to DIN EN 60255-6:11.94
Function controlFunction diagramPower supply circuit
Rated voltage UN ACDC
Rated consumption set to 50 Hz and UN (AC)Rated consumption set to UN (DC)Rated frequencyOperating voltage rangeMeasuring circuit
Electrical isolationReference temperatureLimit value settingSwitching hysteresisHysteresis set with reference to the pre-selected limit valueMean value of the faultDispersionInfluence of the supply voltageInfluence of the ambient temperatureOutput circuit
Contact assignmentContact materialRated operating voltage Un
Max. continuous current In per contact Application category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gGPermissible switching frequencyMechanical lifeResponse time tA
Release time tR
General information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Noise immunity according to IEC 61000-4Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
STW 1001 STW 1002
Monitoring of the limit temperature value Monitoring of the limit temperature valuefor NiCr-Ni sensor according to for NiCr-Ni sensor according toDIN IEC 584 T1 type K. DIN IEC 584 T1 type K.Linearity error is not compensated. Linearity error is not compensated.Adjustable limit value and hysteresis. Adjustable limit value and hysteresis.Monitoring of the sensor line for Monitoring of the sensor line for cable damage. cable damage.Open-circuit principle, Open-circuit principle,temperature transgression temperature transgression1 LED green, 2 LEDs red 1 LED green, 2 LEDs redFD 0110 W1 FD 0112 W1
220 – 240 V 220 – 240 V
24 V
3.3 VA 3.3 VA2.5 W
50 – 60 Hz0.8 – 1.1 x UN
yes (no for 24 V DC rated voltage)+25 °C0 – +999, digitalapprox. 0.5 K0.2 % to ≥ 10 %, analog± 1.5 % ± 1 Digit± 1 %≤ ± 0.02 % / % ∆UN
≤ ± 0.01 % / K∆T
2 change-over contactsAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h30 x 106 switching cycles50 ms50 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3 – 18KS 0283/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.29 kgCover Z 29–
Overview of devices/Part numbers
Type Rated voltage Part number Std. Pack
STW 1001 DC 24 V R3.187.0050.1 1AC 220 – 240 V 50 – 60 Hz R3.187.0010.1 1
STW 1002 AC 220 – 240 V 50 – 60 Hz R3.187.0020.0 1
674 Subject to change without further notice
Lamp tester with common anodes
• 11 diodes• Common anodes• Diode reverse voltage 400 V• Rated diode current 1A• Avalanche power 5 kW/10 µs
Circuit diagram
Applications
• Testing of signal lamps in machine control systems or home automation systems• Common message of control signals, common function test• Signal isolation for function test• Linking of control signals in central fault indicator units• Remote collection of input signals for PLC systems• Interpolation of collected fault indicators• Used as freewheeling diode for coils
Function
The relay consists of a diode circuit with common anode. During operation, the diodecircuit prevents mutual interference of the signal lamp control circuits.
Dimension diagram
Notes
• With alternating voltages, a half-wave rectification occurs, meaning a voltage split!• In AC circuits, capacitive series resistances may cause malfunctions.• When avalanche diodes are used, the devices are especially insensitive to transient
overvoltages.
interfaceinterfaceMeasuring and monitoring relaysLamp tester/diode gate NLT 1001
K3-3NLT 1001 KS 250-11-3
675Subject to change without further notice
interfaceMeasuring and monitoring relaysLamp tester/diode gate NLT 1001
Technical data
Function
Power supply circuit
Diode reverse voltageRated diode currentConducting-state voltage at rated currentAvalance power, 10 µsMax. total currentGeneral information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
NLT 1001
Diode gate, lamp tester, 11 diodes, common anode
400 V1 A≤ 1.2 V5 kW3 A
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30/IP 20–20 – +60 °CK 1-14 W3KS 0223/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.13 kg––
Application examples
Testing of signal lamps
If the test key is operated, all signal lamps connected to the NLT 1001 will light up.Testing of I/O devices in an automation system
The NLT 1001 tests the external I/O devices of the PLC. If the test key is pressed,the functions of all I/O devices can be checked.
Notice! For this test method, the PLC outputs must be protected againstenergetic recovery.
Overview of devices/Part numbers
Type Rated voltage Part number Std. Pack
NLT 1001 11 diodes, total current ≤ 3 A R3.194.0030.0 1
676 Subject to change without further notice
Lamp tester with the cathodes and anodes separated
• 6 diodes• Anode and cathode separated• Diode reverse voltage 400 V• Rated diode current 1A• Avalanche power 5 kW/10 µs
Applications
• Rectification• Testing of signal lamps in machine control systems or home automation systems• Disabling of control signals• Common message of control signals, complete function test• Signal isolation for function test• Linking of control signals in central fault indicator units• Remote collection of input signals for PLC systems• Interpolation of collected fault indicators• Used as freewheeling diode for coils
Circuit diagram
Function
The relay consists of a diode circuit. During operation, the diode circuit preventsmutual interference of the signal lamp control circuits.
Notes
• With alternating voltages, a half-wave rectification occurs, meaning a voltage split!• In AC circuits, capacitive series resistances may cause malfunctions.• When avalanche diodes are used, the devices are especially insensitive to transient
overvoltages.
Dimension diagram
interfaceinterfaceMeasuring and monitoring relaysLamp tester/diode gate NLT 1003
NLT 1003 KS 250-11-4
677Subject to change without further notice
interfaceMeasuring and monitoring relaysLamp tester/diode gate NLT 1003
Technical data
Function
Power supply circuit
Diode reverse voltageRated diode currentConducting-state voltage at rated currentAvalance power, 10 µsMax. total currentGeneral information
Creepage distances and clearances between the circuitsRated impulse voltageOvervoltage categoryPollution degreeRated voltageTest voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminals according to DIN VDE 0470 sec. 1:11.92Ambient temperature, operating rangeDimension diagramCircuit diagramConnector cross sections fine-stranded / solid
or fine-stranded with ferrulesPermissible tightening torqueWeightAccessoriesApprovals
Application example
NLT 1003
Diode gate, lamp tester,6 diodes, anode and cathode separated
400 V1 A≤ 1.2 V5 kW3 A
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30/IP 20–20 – +60 °CK 1-14 W3KS 0225/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.13 kg––
Signal coupling
Overview of devices/part numbers
Type Number of diodes Part number Std. Pack
NLT 1003 6 diodes, total current ≤ 3 A R3.194.0040.0 1
678 Subject to change without further notice
Contact protection relay
• Supply voltage and control circuit electrically isolated• ON-delay and OFF-delay times adjustable between 0.05 and 1 s• Contact assignment:
SST 12: 2 change-over contactsKST 12: 1 normally open, 1 normally closed
Applications
• Protection of sensitive switching contacts such as measuring instruments,manometers pressure monitors
• Avoidance of contact bouncing• As timer relay for short times (ON-delay and OFF-delay times)• As level monitor in connection with float switches
Function
SST 12
The contact protection relay is constantly connected to a supply voltage. The supplyvoltage circuit and the control circuit are electrically isolated by means of atransformer.
If the control circuit is closed (for example by exceeding the limit value in a contactmanometer), the relay will switch into the ON position when the pre-selected ON-delay time has elapsed.When the control contact is opened, it will switch back into the OFF position afterelapse of the OFF-delay time. The ON-delay time and the OFF-delay time are identical.
The open control contact is supplied with a voltage ≤ 11 V DC. A current ≤ 2 mA DCflows over the closed control contact. This way, the control contact is not overloaded.
Contact assignment: 2 change-over contacts
KST 12
It functions just like the SST 12, however the number of contacts are 1 NO, 1 NC.
Notes
• On contact manometers, a control contact indicates the exceeding of the pre-selected limit value. The contact should not impede the movement of the pointer. In order to fulfill this condition, very small control contacts are used. They support amaximum load of 25 mW.With higher loads the contacts would be destroyed.
• A correct function is guaranteed if the total ohmic value of lines and contactresistances does not exceed 500 Ω.
Circuit diagram
Accessories
Cover Z 29 for SST 12
interfaceinterfaceMeasuring and monitoring relaysContact protection relay SST 12, KST 12
SST 12 KST 12
679Subject to change without further notice
interfaceMeasuring and monitoring relaysContact protection relay SST 12, KST 12
Function diagram
Application example
Protection of a manometer contact
The manometer monitors the pressure in the pipeline. If the pressure exceeds thepre-selected limit value, the contact protection relay switches into the ON position. Asignal is transmitted to the PLC. The valve is closed. The lamp H1 indicates that thelimit value has been exceeded.
Dimension diagram
for DIN rail according to EN 50022
for DIN rail according to EN 50022
Manometer
Faultindicator
Supply voltage
LED SUPPLY
Control contact
LED TRIPPED
15/18; 25/28 17/1815/16; 25/26 25/26
SST 12 KST 12
tA = response timetR = release timet1 = switch-on time, must be >
recoverytime 1
t2 = switch-off time, must be >recoverytime 2
PLC
interfaceinterfaceMeasuring and monitoring relaysContact protection relays SST 12, KST 12
680 Subject to change without further notice
Technical data
Function type according to DIN VDE 0435 sec. 2021:09.86 Function control Function diagramPower supply circuit
Rated voltage UN ACRated consumption at 50 Hz and UN (AC) Rated consumption at 50 Hz and UN (AC) Rated frequency Operating voltage rangeTime circuit
Time Setting / number of time ranges Available time range Recovery time 1 / 2 Min. Switch-on time Release value Permissible parallel loads Internal half-wave rectification Mean value of the error Electrical isolation Voltage at open voltage contact Y1 Current through closed control contact Y1 Maximum resistance of the control circuitOutput circuit
Contact assignment Contact material Rated operating voltage Un
Max. continuous current In per contact Application category according to EN 60947-5-1:1991
Short circuit protection; max. fuse insert class gG Permissible switching frequency Mechanical life Response time tA
Release time tR
General information
Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Pollution degree Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1, table A.1
Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Conductor cross sections fine-stranded / solid
or fine-stranded with ferrules Permissible tightening torque Weight Accessories Approvals
SST 12 KST 12
Contact protection relay1 green LED, 1 red LEDFD 0082 W1
24 V 110 – 127 V 220 – 240 V 110 V 220 – 240 V
3.2 VA 2.7 VA 3.2 VA 1.5 VA 1.5 VA2.8 W 2.4 W 2.8 W 1.6 W 1.6 W50 – 60 Hz0.8 – 1.15 x UN
analog / 10.05 – 1 s200 / 200 ms––nono± 20 %yes≤ DC 11 V≤ 2 mA500 Ω
2 change-over contacts 1 normally closed, 1 normally openAg alloy, gold-platedAC/DC 230/230 V5 AAC-15: Ue 230 V AC, Ie 3 ADC-13: Ue 24 V DC, Ie 2 A6 A≤ 6000 switching cycles/h ≤ 3600 switching cycles/h30 x 106 switching cycles 20 x 106 switching cycles10 ms10 ms
according to DIN VDE 0110-1:04.974 kVIII3 outside, 2 inside250 V AC2.21 kVIP 30 / IP 20Test severity 3–20 – +60 °CS 3-2 K 1-12 W3KS 0138/1 KS 0287/12 x 0.75 – 1.5 mm2 / 2 x 0.75 – 2.5 mm2
1 or 2 x 0.5 – 1.5 mm2
0.8 – 1 Nm0.4 kg 0.17 kgCover Z 29 ––
Overview of devices/part numbers
Type ON-delay time / OFF-delay time Rated voltage Part number Std. Pack
SST 12 0.05 – 1 s AC 24 V 50 – 60 Hz R3.191.0020.3 1AC 110 V 50 – 60 Hz R3.191.0050.3 1AC 220 – 240 V 50 – 60 Hz R3.191.0030.3 1
KST 12 0.05 – 1 s AC 110 V 50 – 60 Hz R3.191.0040.0 1AC 220 – 240 V 50 – 60 Hz R3.191.0010.0 1
681Subject to change without further notice
interfaceMeasuring and monitoring relaysAccessories
Cover Z 29
Function sealable transparent cap forhousing S 3-1, S 3-2, S 3-9, S 3-12
Material Polycarbonate (PC)Color transparentFlammability according to UL standard 94 V-1Weight 0.01 kgStandard pack 5 piecesPart number R9.211.0090.0
Accessories for discontinued models
Discontinued model Part number Std. Pack Successor type
DA 1-101 R9.211.0030.0 10 –K 1-5/5 R9.210.0020.0 1 NGG housingsSN 18 R9.216.0010.0 1 –V 4-101 R9.211.0020.0 1 –
Dimensions in mm
ø 1.5 for sealing
interfaceMeasuring and monitoring relaysDiscontinued models
682 Subject to change without further notice