bss integration
Post on 02-Nov-2014
170 Views
Preview:
TRANSCRIPT
GSM/EDGE BSS, Rel. RG20(BSS), Operating Documentation, Issue 05
Integrate and configure
BSS Integration
DN9812243
Issue 21-1Approval Date 2010-11-25
Confidential
2 DN9812243Issue 21-1
BSS Integration
Id:0900d805808a0773Confidential
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2011. All rights reserved
f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.
The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set.
The same text in German:
f Wichtiger Hinweis zur Produktsicherheit Von diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal, Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-satzes.
DN9812243 3
BSS Integration
Id:0900d805808a0773Confidential
Table of contentsThis document has 114 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1 Overview of BSS integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 A interface protocol layers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 A interface configuration with TCSM2 and TCSM3i. . . . . . . . . . . . . . . . 11
4 ET indexes in BSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5 Creating the A interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 595.1 Connecting the A interface ET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 595.2 Connecting the optical A interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615.3 Connecting the PWE interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635.4 Creating the transcoder devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635.4.1 Creating the TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645.4.2 Creating TCSM3i for combined BSC/TCSM installation . . . . . . . . . . . . 685.4.3 Creating the TCSM2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715.5 Creating Ater Connection to Multimedia Gateway. . . . . . . . . . . . . . . . . 795.6 Creating the MTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 825.7 Creating the SCCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 855.8 Creating the speech channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
6 Synchronising the A interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
7 Adding DN2, SSS, DMR and BBM to the service channel . . . . . . . . . . 93
8 Creating the Abis interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
9 Initialising base stations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 979.1 Creating LAPD links and a base station, and initialising the base station pa-
rameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 979.2 Attaching the BCF software build to the BCF . . . . . . . . . . . . . . . . . . . 1009.3 Attaching the BTS hardware database to the BTS . . . . . . . . . . . . . . . 1029.4 Taking the base station into use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
10 Testing BSS integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10510.1 Testing local blocking of a TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10510.2 Testing the supervision of the TCSM2 (ETSI/ANSI) . . . . . . . . . . . . . . 10610.3 Testing the supervision of the TCSM3i (ETSI/ANSI) . . . . . . . . . . . . . . 10610.4 Testing IMSI Attach . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10710.5 Testing location updating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10710.6 Testing MS to MS call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10710.7 Testing MS to MS call, B busy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10810.8 Testing MS to MS call, A subscriber IMSI detach . . . . . . . . . . . . . . . . 10910.9 Testing successful handover: free TCHs . . . . . . . . . . . . . . . . . . . . . . . 10910.10 Testing unsuccessful handover: no free TCHs . . . . . . . . . . . . . . . . . . 11010.11 Testing radio resource queuing in handover . . . . . . . . . . . . . . . . . . . . 110
11 Test logs for BSS integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
4 DN9812243
BSS Integration
Id:0900d805808a0773Confidential
List of figuresFigure 1 Three layers of CCS7/SS7 signalling between MSC and BSC. . . . . . . . 10Figure 2 A interface configuration example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Figure 3 Time slot allocation for full-rate traffic on Ater 2 Mbit/s interface with the
TCSM2 (ETSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Figure 4 A interface time slot allocation (ANSI) . . . . . . . . . . . . . . . . . . . . . . . . . . 17Figure 5 ET cartridges in the BSCC cabinet of BSC3i 1000 . . . . . . . . . . . . . . . . . 36Figure 6 ET cartridges in the BSCD extension cabinet of BSC3i 2000. . . . . . . . . 37Figure 7 ET cartridges in the new delivery Flexi BSC. . . . . . . . . . . . . . . . . . . . . . 38Figure 8 ET cartridges in the upgraded Flexi BSC . . . . . . . . . . . . . . . . . . . . . . . . 39Figure 9 GTIC cartridges in TCSM3i for combined BSC/TCSM installation . . . . . 41Figure 10 ET4C-B cartridges with GSWB and ET2A/ET2A-T(B)/ET2E-S/SC/ET2E-
T(B)/ET2E-TC(B) indexes in BSC3i 660. . . . . . . . . . . . . . . . . . . . . . . . . 54Figure 11 ET4C-B cartridges with GSW1KB and ET4A/ET4E/ET4E-C indexes in
BSC3i 660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Figure 12 ET4C-B cartridges with GSW1KB and ET2A/ET2A-T(B)/ET2E-
S/SC/ET2E-T(B)/ET2E-TC(B) indexes in BSC3i 660 . . . . . . . . . . . . . . . 56Figure 13 ET5C cartridges and ET2E/ET2A indexes in BSC2i. . . . . . . . . . . . . . . . 57Figure 14 TCSM3i ET (ET16 or ETIP) units and transcoder units . . . . . . . . . . . . . 65Figure 15 Configuration of the TCSM3i for combined BSC/TCSM installation . . . . 68Figure 16 TCSM2 rack and cartridges (ETSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Figure 17 TCSM2 rack and cartridges (ANSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Figure 18 Ater interface with MGW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Figure 19 Multiplexed and non-multiplexed A interface with 8 kbit GSWB . . . . . . . 87Figure 20 Transmission equipment at Q1 service channel . . . . . . . . . . . . . . . . . . . 93Figure 21 Abis interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Figure 22 BTS software directories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101Figure 23 The test arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
DN9812243 5
BSS Integration
Id:0900d805808a0773Confidential
List of tablesTable 1 Circuit types supported by the TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . 12Table 2 Allocation of different channels on the Ater-interface in the case of 16 kbit/s
TRAU frame submultiplexing (circuit type G) . . . . . . . . . . . . . . . . . . . . 12Table 3 Channel allocation for circuit type H on the Ater-interface . . . . . . . . . . 13Table 4 Channel allocation for circuit type I on the Ater-interface . . . . . . . . . . . 14Table 5 ET indexes in BSC3i 1000/2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 6 ET indexes in BSC3i 1000/2000 (ETSI ETS2, two active and two standby
STM-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Table 7 ET indexes in BSC3i 1000/2000 (ETSI ETS2, one active and one standby
STM-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Table 8 ET indexes in BSC3i 1000/2000 (ANSI ETS2, two active and two standby
OC-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Table 9 ET indexes in BSC3i 1000/2000 (ANSI ETS2, one active and one standby
OC-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Table 10 ETIP and ET indexes in BSC3i 1000/2000 when transmission redundancy
is in use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Table 11 ETIP and ET indexes in BSC3i 1000/2000 when HW redundancy is in use
26Table 12 ETIP and ET indexes in new delivery Flexi BSC when transmission redun-
dancy is in use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Table 13 ETIP and ET indexes in upgraded Flexi BSC when transmission redundan-
cy is in use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Table 14 ETIP and ET indexes in new delivery Flexi BSC when HW redundancy is
in use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Table 15 ETIP and ET indexes in upgraded Flexi BSC when HW redundancy is in
use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Table 16 ET indexes in new delivery Flexi BSC when transmission redundancy is in
use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Table 17 ET indexes in upgraded Flexi BSC when transmission redundancy is in
use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Table 18 ET indexes in new delivery Flexi BSC cartridges when HW redundancy is
in use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Table 19 ET indexes in upgraded Flexi BSC cartridges when HW redundancy is in
use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Table 20 ET indexes in TCSM3i for combined BSC/TCSM installation . . . . . . . . 40Table 21 ET indexes (ETS2) in TCSM3i for combined BSC/TCSM installation with
upgraded and new delivery Flexi BSC when transmission redundancy is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 22 ET indexes (ETS2) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when HW redundancy is used . 45
Table 23 ET indexes (ETIP) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when transmission redundancy is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table 24 ET indexes (ETIP) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when HW redundancy is used . 50
Table 25 ET indexes with GSWB in BSCi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Table 26 Default synchronisation ETs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Table 27 TR3E/TR3A/TR3T roles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
6 DN9812243
BSS Integration
Id:0900d805808a0773Confidential
Table 28 Possible combinations of circuit pools (TCSM3i) . . . . . . . . . . . . . . . . . . 67Table 29 Possible combinations of circuit pools . . . . . . . . . . . . . . . . . . . . . . . . . . 76Table 30 TCSM3i capacity with four TR3E unequipped . . . . . . . . . . . . . . . . . . . . 79Table 31 Circuit pools and supported codecs (with SubChannel bit information)
when using MGW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Table 32 BSS specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Table 33 Creating the A interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Table 34 Creating the Abis interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113Table 35 Initialising the base stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113Table 36 Testing BSS integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
DN9812243 7
BSS Integration Summary of changes
Id:0900d8058086ac41Confidential
Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.
Changes made between issues 21-2 and 21-1The document is updated with the information on mcBSC.
Chapter Overview of BSS integration has been modified.
Changes made between issues 21-1 and 21-0In chapter ET indexes in BSC, some sections have been modified and editorial changes have been done.
Changes made between issues 21-0 and 20-0The document is updated with the information on Flexi BSC, TCSM3i, Flexi Multiradio BTS, and BTSplus BTS.
Chapters Overview of BSS integration, Creating the A interface, Synchronising the A interface and Initialising base stations have been modified.
Changes made between issues 20-0 and 19-1In chapter Overview of BSS integration, information on Multimedia Gateway and Flexi BSC has been added.
In chapter A interface configuration with TCSM2 and TCSM3i, information on the ETIP1-A plug-in unit, the Multipoint A interface and the Ater interface has been added.
In chapter ET indexes in BSC, information on ETIP1-A plug-in unit, and ETIP and ET indexes in BSC3i 1000/2000 and Flexi BSC has been added.
In chapter Creating the A interface, instructions for using ETIP plug-in unit has been added.
Chapter Synchronising the A interface has been slightly modified.
Changes made between issues 19-2 and 19-1In chapter Creating the A interface, section Creating the SCCP, more information on using segmentation was added.
Changes made between issues 19-1 and 19-0Chapter Initialising base stations: added information on Flexi EDGE Base Station auto-matic unlock.
8 DN9812243
BSS Integration
Id:0900d8058086ac4fConfidential
Overview of BSS integration
1 Overview of BSS integrationBSS integration instructions are intended to be used during the integration of the TCSM-BSC-BTS system in the final location.
The BSS integration testing can be started when the commissioning of the different network elements has been done.
The purpose of the BSS integration tests is to ensure that the BSC, TCSM, and BTS operate correctly together in the GSM/GPRS/EDGE network. When the BSS integration tests have been performed, the base station subsystem can be taken into use.
There are different product variants of the Base Station Controller: BSCi, BSC2i, BSC3i660, BSC3i 1000, BSC3i 2000, Flexi BSC and mcBSC. Flexi BSC has two vari-ants: upgraded Flexi BSC and new delivery Flexi BSC.
In the Flexi BSC, new HW elements CP1D-A ( New processor unit with multicore capa-bility), ETP(Exchange Terminal for Packet Transmission for Packet Abis over TDM and Packet Abis over Ethernet) and ETP-A (Packet gateway for AoIP) are introduced to support 4200 TRX, Packet Abis over ETH or TDM and Packet gateway for AoIP.
There are ETIP1-A plug in unit and ESB24-D plug-in unit. The ETIP1-A plug in unit provides one active and one protecting Gigabit Ethernet interface. The ETIP1-A is rep-resented by two functional units: Exchange terminal for IP transmission unit ETIP and Ethernet Exchange Terminal unit (EET). The EET represents a functional unit of a physical GigE Ethernet interface.
The ESB24-D plug-in unit is used with Ethernet based Message Bus (EMB) as a collec-tor of EMB LANs from the CPU units in both new delivery and upgraded Flexi BSC. ESB24-D can also be used as a generic LAN switch in the new delivery Flexi BSC.
The mcBSC (Multicontroller BSC) can be used in two ways. It can be used as a totally new BSC option for new installations with standalone multicontroller BSC modules.
Thesecond one is - capacity can be flexibly extended for the existing installed Flexi BSC base using the new HW module implementation of the Multicontroller. In this case, mcBSC enables the evolution of installed Flexi BSCs towards multicontroller capability.
Transcoding functionality is usually performed in a separate standalone network element (TCSM2/TCSM3i/mcTC), and the interface between the Base Station Control ler (BSC) and the transcoder (TC) is called Ater. As an alternative to standalone 2G transcoders MGW offers the Ater interface (2G transcoder) functionality. Thus transcod ing can be performed also by the transcoder located in the Multimedia Gateway (MGW).In creation of the Ater connection to the Multimedia Gateway, no configuration or controlling the TCSM is needed. The TCSM and the transcoder in the MGW are con figured differently in the BSC. For information, see Multimedia Gateway Product Docu mentation. The mcTC is used as a transcoding solution for standalone and combined mcBSC cases. TCSM2 and TCSM3i can be used in parallel with mcTC in combined mcBSC. Combined BSC/TCSM installation is also supported here.
As a part of capacity upgrade for TCSM3i, IC209-A cabinet is used to allow the equip-ping of five full shelf wide transcoder cartridge. Cabling Cabinet is not equipped with E1 balanced interfaces if new Rear Cabling Modules are used. TC1C-A is the new cartridge for TCSM3i and ETP-A is the new Exchange Terminal for Packet Transport. The capacity in one S15 standalone TCSM3i cabinet is 14400 channels.The capacity of one S15 combined TCSM3i cabinet in full configuration is 16800 channels, but 16320 channels is the maximum capacity reached, due to the channel sales configuration step.
DN9812243 9
BSS Integration Overview of BSS integration
Id:0900d8058086ac4fConfidential
Creating a connection to the network management system for BSC2i and BSC3i is described in the following documents:
• Integrating 2GBSS to NetAct in NetAct documentation
Creating a connection to the SGSN is described in SGSN Integration in SGSN docu-mentation. Creating the connection in BSC is described in Enabling GPRS in BSC in BSC documentation.
Creating a connection to the Cell Broadcast Centre is described in BSC-CBC Integration in BSC documentation.
Creating TCP/IP connections through LAN switches for BSC3i is described in BSC Site IP Connectivity Guidelines in BSC documentation.
For more information on the effects due to mcBSC, please check BSS21341: A over IP and BSS21454: Packet Abis over Ethernet in BSC documentation.
Any detected fault should be reported with a Nokia problem report and the report should be sent to the Customer Service Centre.
BSS integration procedureThe main phases of the testing are executed in the order presented here. BSS integra-tion consists of the following phases:
1. Creating the A interface2. Synchronising the A interface3. Adding DN2, SSS, DMR and BBM to the service channel4. Creating the Abis interface5. Creating X.25 or LAN connections. See Integrating 2GBSS to NetAct in NetAct doc-
umentation (for BSC2i and BSC3i).6. Initialising base stations7. Testing BSS integration
Test logs can be filled in during the testing.
For more information on BSS integration, see also:
• A interface protocol layers • A interface configuration with TCSM2 and TCSM3i • ET indexes in BSC3i, BSC2i and BSCi
10 DN9812243
BSS Integration
Id:0900d805805ceddcConfidential
A interface protocol layers
2 A interface protocol layersIn the ETSI environment, the A interface is defined in accordance with CCITT#7 Signal-ling System. In the ANSI environment, the A interface is defined in accordance with ANSI SS7 Signalling System. Three protocol layers are used: the Message Transfer Part (MTP), the Signalling Connection Control Part (SCCP), and the BSS Application Part (BSSAP; with ETSI) or the Radio System Application Part (RSAP; with ANSI), as shown in the figure below.
Figure 1 Three layers of CCS7/SS7 signalling between MSC and BSC
The MTP's task is to provide a reliable means of data transmission. It consists of a sig-nalling link, a signalling link set, and a signalling route set.
The SCCP complements the services of the MTP by providing connectionless and con-nection-oriented network services. It consists of SCCP subsystems.
The BSSAP/RSAP uses the services of the MTP and the SCCP. It takes care of actual GSM/DCS-related interaction between the MSC and the BSS. Typical tasks of the BSSAP/RSAP are for example call control, location updates, handover management, and paging. It has no counterparts in terms of BSC MMI but is created along with the SCCP.
For an overview, see Overview of BSS integration.
MSC BSCTCSM
BSSAP / RSAP
MTP
SCCP
MTP
SCCP
BSSAP / RSAP
Signalling linksthrough connected
DN9812243 11
BSS Integration A interface configuration with TCSM2 and TCSM3i
Id:0900d805805ceddfConfidential
3 A interface configuration with TCSM2 and TCSM3iThe A interface configuration can be made in many different ways depending on the equipment, or capacity and redundancy requirements. For example, the transcoder can be either TCSM2 or TCSM3i. Likewise, it is possible to implement only one PCM, E1 (used in ETSI environment), or T1 (used in ANSI environment) line between the MSC and the BSC or to use several separate PCM lines for redundancy or capacity purposes. The following figure illustrates an A interface configuration example.
With both TCSM2 and TCSM3i, the A interface is always multiplexed.
Figure 2 A interface configuration example
Signalling can also be performed using IETF signalling transmission (SIGTRAN). For more information, see SIGTRAN Configuration for the A Interface.
Multipoint A Interface enables one BSC to be connected to several core network elements (MSCs or MSC Servers). Even though one core network element fails, the network can stay operational with reduced capacity. For more information, see Multi-point A Interface in BSC.
TCSM3i for combined BSC/TCSM installationIn combined BSC/TCSM installation, no E1 or T1 interfaces are used as Ater interfaces between the BSC and TCSM3i. Instead, internal serial broadband interfaces (SBI) or Hotlinks are used. STM-1/OC-3 or IP/Ethernet (GigE) interfaces are used as external A interfaces.
MSC
TCSM3iEQUIPMENT
TCSMunit
Aterinterface
Ainterface
TCSMunit
DN0626652
0
0
1
2
3
4
1
2
3
4
BSC
E1/T1or
STM-1/OC-3or
IP/EthernetMSC
MSCMSC
E1/T1or
IP/Ethernetor
Int. PCM
E1/T1or
STM-1/OC-3or
IP/Ethernet
E1/T1or
IP/Ethernetor
Int. PCM
12 DN9812243
BSS Integration
Id:0900d805805ceddfConfidential
A interface configuration with TCSM2 and TCSM3i
In TCSM3i for combined BSC/TCSM installation with a Flexi BSC, a mixed ETS2 and ETIP1-A configuration (STMU and SET, and ETIP and EET units) is possible in A-inter-faces.
TCSM3i
The TCSM3i uses an allocation with 16 kbit/s traffic channels for the use of HR speech, FR speech, EFR speech, AMR (FR and HR) speech traffic, and FR data traffic. An example is shown in the table below.
Circuit type
Supported channels and speech coding algo-rithms
Capacity unit on Ater interface
G HR speech, FR speech, EFR speech, AMR-FR speech, AMR-HR speech, or AMR-WB speech
FR data traffic
16 kbit/s
H HR speech, FR speech, EFR speech, AMR-FR speech, AMR-HR speech, or AMR-WB speech
FR data traffic
HSCSD max 2* FR data traffic
32 kbit/s
I HR speech, FR speech, EFR speech, AMR-FR speech, AMR-HR speech, or AMR-WB speech
FR data traffic
HSCSD max 4* FR data traffic
64 kbit/s
Table 1 Circuit types supported by the TCSM3i
Bits
TS 1 2 3 4 5 6 7 8
01 LAPD 2 3 4
02 5 6 7 8 Channels of:
03 9 10 11 12 PCM1
04 13 14 15 16
05 17 18 19 20
06 21 22 23 24
07 1 2 3 4
08 5 6 7 8 Channels of:
09 9 10 11 12 PCM2
10 13 14 15 16
11 17 18 19 20
12 21 22 23 24
13 1 2 3 4
Table 2 Allocation of different channels on the Ater-interface in the case of 16 kbit/s TRAU frame submulti-plexing (circuit type G)
DN9812243 13
BSS Integration A interface configuration with TCSM2 and TCSM3i
Id:0900d805805ceddfConfidential
The basic requirement for high-speed circuit-switched data (HSCSD) data transmission capability is that the associated BSC is equipped with an 8 kbit/s switching network or Bit Group Switch. Channel allocations for TCSM3i configured to transmit the data exclu-sively at the maximum rate of 32 kbit/s (type H) and 64 kbit/s (type I) are shown in the following tables. The same allocations accept also speech channels (FR/EFR, HR) instead of data, allowing an optimised use of transmission capacity for mixed speech/data use. The capacity unit reserved for an HSCSD connection on the A-inter-face is:
• 8–32 kbit/s (4 bits of a timeslot) for a 2 × 16 kbit/s channel • 8–64 kbit/s (an entire timeslot) for a 4 × 16 kbit/s channel
14 5 6 7 8 Channels of:
15 9 10 11 12 PCM3
16 13 14 15 16
17 17 18 19 20
18 21 22 23 24
19 1 2 3 4
20 5 6 7 8 Channels of:
21 9 10 11 12 PCM4
22 13 14 15 16
23 17 18 19 20
24 21 22 23 24
F
Table 2 Allocation of different channels on the Ater-interface in the case of 16 kbit/s TRAU frame submulti-plexing (circuit type G) (Cont.)
Bits
TS 1 2 3 4 5 6 7 8
00 TS 0
01 LAPD - 2
02 3 4
03 5 6
04 7 8
05 9 10 Channels of:
06 11 12 PCM1
07 13 14
08 15 16
09 17 18
10 19 20
11 21 22
Table 3 Channel allocation for circuit type H on the Ater-interface
14 DN9812243
BSS Integration
Id:0900d805805ceddfConfidential
A interface configuration with TCSM2 and TCSM3i
12 23 24
13 1 2
14 3 4
15 5 6
16 7 8
17 9 10 Channels of:
18 11 12 PCM2
19 13 14
20 15 16
21 17 18
22 19 20
23 21 22
24 23 24
F
Bits
TS 1 2 3 4 5 6 7 8
00 TS 0
01 LAPD -
02 2
03 3
04 4
05 5
06 6
07 7
08 8
09 9
10 10
11 11 Channels of:
12 12 PCM1
13 13
14 14
15 15
16 16
17 17
18 18
Table 4 Channel allocation for circuit type I on the Ater-interface
Table 3 Channel allocation for circuit type H on the Ater-interface (Cont.)
DN9812243 15
BSS Integration A interface configuration with TCSM2 and TCSM3i
Id:0900d805805ceddfConfidential
TCSM2, ETSIProvided that the BSC is equipped with an 8 Kbit group switch (GSWB), four separate A interface lines can be put into one highway PCM, making it possible to have up to 120 full-rate speech channels in one highway PCM cable. In half-rate configuration the maximum number of speech channels is 210. The combination of half-rate and full-rate can also be used.
The maximum efficiency is achieved if the recommendation for time slot allocation is followed (shown in the figure Time slot allocation for full-rate traffic on Ater 2 Mbit/s inter-face with the TCSM2 (ETSI)).
Signalling channels, and possibly network management system connections, are always allocated beginning from the end of the frame. This optimises the number of the traffic channels available for the fourth tributary. This is due to the fact that only the time slots preceding the first signalling time slot can be used as speech channels in the fourth tributary.
For example, if signalling links are allocated to time slots 31 and 27, only the time slots 25 and 26 are available for the fourth tributary - even if time slots 30, 29, and 28 are not used at all.
19 19
20 20
21 21
22 22
23 23
24 24
F
Table 4 Channel allocation for circuit type I on the Ater-interface (Cont.)
16 DN9812243
BSS Integration
Id:0900d805805ceddfConfidential
A interface configuration with TCSM2 and TCSM3i
Figure 3 Time slot allocation for full-rate traffic on Ater 2 Mbit/s interface with the TCSM2 (ETSI)
TCSM2, ANSIBecause of multiplexing, four A interface T1s can be put to one highway T1, making it possible to have up to 96 traffic channels between the transcoder and the BSC as shown in figure A interface time slot allocation (ANSI). However, one channel is required for the LAPD channel and normally one 64 kbit time slot is used for SS7 signalling. This leaves 91 channels for traffic.
BIT->
TS-> LINK MANAGEMENT0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
LAPD
TCH.4
TCH.8
TCH.12
TCH.16
TCH.20
TCH.24
TCH.28
x
TCH.4
TCH.8
TCH.12
TCH.16
TCH.20
TCH.24
TCH.28
x
TCH.4
TCH.8
TCH.12
TCH.16
TCH.20
TCH.24
TCH.28
TCH.1
TCH.5
TCH.9
TCH.13
TCH.17
TCH.21
TCH.25
TCH.29
TCH.1
TCH.5
TCH.9
TCH.13
TCH.17
TCH.21
TCH.25
TCH.29
TCH.1
TCH.5
TCH.9
TCH.13
TCH.17
TCH.21
TCH.25
TCH.29
TCH.2
TCH.6
TCH.10
TCH.14
TCH.18
TCH.22
TCH.26
TCH.30
TCH.2
TCH.6
TCH.10
TCH.14
TCH.18
TCH.22
TCH.26
TCH.30
TCH.2
TCH.6
TCH.10
TCH.14
TCH.18
TCH.22
TCH.26
TCH.30
TCH.3
TCH.7
TCH.11
TCH.15
TCH.19
TCH.23
TCH.27
TCH.31
TCH.3
TCH.7
TCH.11
TCH.15
TCH.19
TCH.23
TCH.27
TCH.31
TCH.3
TCH.7
TCH.11
TCH.15
TCH.19
TCH.23
TCH.27
TCH.31
A-PCM 1
A-PCM 2
A-PCM 3
(A-PCM 4)AUX1: selectable (TCH.1-3)
AUX2: selectable (TCH.4-7)
AUX3: selectable (TCH.8-11)
AUX4: selectable (TCH.12-15)
#7 signalling (TCH.16-19)
#7 signalling (TCH.20-23)
#7 signalling (TCH.24-27)
1 2 3 6 84 5 7
DN9812243 17
BSS Integration A interface configuration with TCSM2 and TCSM3i
Id:0900d805805ceddfConfidential
Figure 4 A interface time slot allocation (ANSI)
For an overview, see Overview of BSS integration.
Trunk 3 1 2 3 4 5 6 7 8
TS 1 TCH 1TS 2 TCH 2TS 3 TCH 3TS 4 TCH 4TS 5 TCH 5TS 6 TCH 6TS 7 TCH 7TS 8 TCH 8TS 9 TCH 9TS 10 TCH 10TS 11 TCH 11TS 12 TCH 12TS 13 TCH 13TS 14 TCH 14TS 15 TCH 15TS 16 TCH 16TS 17 TCH 17TS 18 TCH 18TS 19 TCH 19TS 20 TCH 20TS 21 TCH 21TS 22 TCH 22TS 23 TCH 23TS 24 TCH 24
Trunk 2 1 2 3 4 5 6 7 8
TS 1 TCH 1TS 2 TCH 2TS 3 TCH 3TS 4 TCH 4TS 5 TCH 5TS 6 TCH 6TS 7 TCH 7TS 8 TCH 8TS 9 TCH 9TS 10 TCH 10TS 11 TCH 11TS 12 TCH 12TS 13 TCH 13TS 14 TCH 14TS 15 TCH 15TS 16 TCH 16TS 17 TCH 17TS 18 TCH 18TS 19 TCH 19TS 20 TCH 20TS 21 TCH 21TS 22 TCH 22TS 23 TCH 23TS 24 TCH 24
Trunk 4 1 2 3 4 5 6 7 8TS 1 TCH 1TS 2 TCH 2TS 3 TCH 3TS 4 TCH 4TS 5 TCH 5TS 6 TCH 6TS 7 TCH 7TS 8 TCH 8TS 9 TCH 9TS 10 TCH 10TS 11 TCH 11TS 12 TCH 12TS 13 TCH 13TS 14 TCH 14TS 15 TCH 15TS 16 TCH 16TS 17 TCH 17TS 18 TCH 18TS 19 TCH 19TS 20 TCH 20TS 21TS 22TS 23TS 24 SS7
23 TCHs
24 TCHs
24 TCHs
20 TCHs
1 2 3 4 5 6 7 8
TS 1 LAPD TCH 2 TCH 3 TCH 4 Trunk 1
TS 2 TCH 5 TCH 6 TCH 7 TCH 8
TS 3 TCH 9 TCH 10 TCH 11 TCH 12
TS 4 TCH 13 TCH 14 TCH 15 TCH 16
TS 5 TCH 17 TCH 18 TCH 19 TCH 20
TS 6 TCH 21 TCH 22 TCH 23 TCH 24
TS 7 TCH 1 TCH 2 TCH 3 TCH 4 Trunk 2
TS 8 TCH 5 TCH 6 TCH 7 TCH 8
TS 9 TCH 9 TCH 10 TCH 11 TCH 12
TS 10 TCH 13 TCH 14 TCH 15 TCH 16
TS 11 TCH 17 TCH 18 TCH 19 TCH 20
TS 12 TCH 21 TCH 22 TCH 23 TCH 24
TS 13 TCH 1 TCH 2 TCH 3 TCH 4 Trunk 3
TS 14 TCH 5 TCH 6 TCH 7 TCH 8
TS 15 TCH 9 TCH 10 TCH 11 TCH 12
TS 16 TCH 13 TCH 14 TCH 15 TCH 16
TS 17 TCH 17 TCH 18 TCH 19 TCH 20
TS 18 TCH 21 TCH 22 TCH 23 TCH 24
TS 19 TCH 1 TCH 2 TCH 3 TCH 4 Trunk 4
TS 20 TCH 5 TCH 6 TCH 7 TCH 8
TS 21 TCH 9 TCH 10 TCH 11 TCH 12
TS 22 TCH 13 TCH 14 TCH 15 TCH 16
TS 23 TCH 17 TCH 18 TCH 19 TCH 20
TS 24 SS7
Trunk 1 1 2 3 4 5 6 7 8
TS 1TS 2 TCH 2TS 3 TCH 3TS 4 TCH 4TS 5 TCH 5TS 6 TCH 6TS 7 TCH 7TS 8 TCH 8TS 9 TCH 9TS 10 TCH 10TS 11 TCH 11TS 12 TCH 12TS 13 TCH 13TS 14 TCH 14TS 15 TCH 15TS 16 TCH 16TS 17 TCH 17TS 18 TCH 18TS 19 TCH 19TS 20 TCH 20TS 21 TCH 21TS 22 TCH 22TS 23 TCH 23TS 24 TCH 24
Highway T1(to BSC)
A Interface(to MSC)
TCSM2
18 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
4 ET indexes in BSCIn new delivery Flexi BSC both STM-1/OC-3 interfaces (optical) and IP/Ethernet (GigE) interfaces (optical or electrical) are supported in the whole cabinet wide cartridge mechanics together with E1/T1 interfaces. Cartridge mechanics is divided to sub car-tridges, which are used same way as smaller cartridges in earlier delivered BSCs. In upgraded Flexi BSC one-cabinet configuration is supported with full range (16+16) of STM-1/OC-3 interfaces and IP/Ethernet (8 + 8 GigE) interfaces. In the upgraded Flexi BSC it is possible to extend the configuration with a second cabinet also to full support for 800 E1/T1 interfaces to earlier delivered BSCs.
The Exchange Terminals (ETs) of the BSC3i 1000/2000 and the upgraded Flexi BSC are housed in GT6C-A and/or GT4C-A cartridges. One GT4C-A cartridge can contain up to eight ET plug-in units and a GT6C-A cartridge can contain up to four ET plug-in units. ET16 plug-in units can be installed to six ET cartridges with indexes ETC 0 to ETC 5 in BSC3i 2000. Additionally, ET16 units can also be equipped to GTIC cartridges to achieve a maximum of 800 E1/T1 interfaces amount in the two-cabinet configuration and 384 E1/T1 interface amount in the one-cabinet configuration.
The ET16 and ETIP1-A units are installed to GTIC cartridge starting from the right in mixed ET16 or ETIP1-A and ETS2 equipping. In the incoming direction, the ET decodes the 2048 Mbit/s in European Telecommunications Standards Institute (ETSI) signal or 1544 Mbit/s American National Standards Institute (ANSI) signal of a circuit into data signals.
In the outgoing direction, the ET receives a binary PCM signal from the switching network and generates the PCM frame structure. The resulting signal is converted into a line code (HDB3 in the ETSI environment, B8ZS or AMI in the ANSI environment) and transmitted further onto the 2048 Mbit/s (ETSI) or 1544 Mbit/s (ANSI) circuit.
The ETS2 plug-in unit contains up to two active and two redundant optical STM-1/OC-3 interfaces. All optical components have 2N redundancy for transmission protection. A maximum of 16 active optical interface can be achieved with 8 plug-in units, if two active interface per unit is used or with 16 plug-in units if one active interface is used per unit.
The ETS2 units are equipped to GTIC cartridges in the first equipment cabinet. The GTIC cartridges can also be used for E1/T1 connectivity with ET16 units. The ETS2 unit is responsible for framing, mapping, and multiplexing of PCMs into channelised way in optical interfaces (VC12). One STM-1 interface consists of 63 E1s (ETSI) and one OC-3 interface consists of 84 T1s (ANSI). PCMs are handled in the same way as ETs in the ET16 plug-in unit.
Equipment protection for ETS2 (MSP 1 + 1 protective units) is provided if two STMU units (functional units for ETS2) are configured with consecutive indexes. For example, STMU-0 and STMU-1 comprise a pair of STMUs.
Integrated E1/T1 over IP application software offers an integrated solution for BSC3i and TCSM3i based transcoders to send/receive TDM frame timeslots via a packet-switched network. Integrated E1/T1 over IP is based on the circuit emulation service over packet-switched networks (CESoPSN) technology and it is implemented in the ETIP1-A plug-in unit. The ETIP1-A can be equipped to the ETS2 and ET16 cartridges to replace the E1/T1 or STM-1/OC-3 unit. This improves the BSC connectivity. The operator has more alternatives to select transmission technology in different interfaces of the BSC environment. The ETIP-A plug-in unit can be used in the Abis and Ater inter-faces in the BSC3i and in the A and Ater interfaces in TCSM3i based transcoders. The
DN9812243 19
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
capacity of one ETIP1-A plug-in unit in the BSC3i environment is 126 E1 PCMs or 168 T1 PCMs.
ETC cartridge Slot ETs
ETC 0 01 512-527
02 528-543
03 544-559
04 560-575
ETC 1 01 576-591
02 592-607
03 608-623
04 624-639
ETC 2 01 1344-1359
02 1360-1375
03 1376-1391
04 1392-1407
05 1600-1615
06 1616-1631
07 1632-1647
08 1648-1663
ETC 3 01 1664-1679
02 1680-1695
03 1696-1711
04 1712-1727
05 1728-1743
06 1744-1759
07 1760-1775
08 1776-1791
ETC 4 01 1920-1935
02 1936-1951
03 1952-1967
04 1968-1983
05 1984-1999
06 2000-2015
07 2016-2031
08 2032-2047
ETC 5 01 1280-1295
02 1296-1311
Table 5 ET indexes in BSC3i 1000/2000
20 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
Slot STM-1 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ETSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 64-126 640 (0-15)
0 1 0 64-126 640 (0-15)
1 0 0 192-254 640 (0-15)
1 1 0 192-254 640 (0-15)
02 0 0 2 320-382 640 (16-31)
0 1 2 320-382 640 (16-31)
1 0 2 448-510 640 (16-31)
1 1 2 448-510 640 (16-31)
03 0 0 4 1088-1150 641 (0-15)
0 1 4 1088-1150 641 (0-15)
1 0 4 1216-1278 641 (0-15)
1 1 4 1216-1278 641 (0-15)
04 0 0 6 1408-1470 641 (16-31)
0 1 6 1408-1470 641 (16-31)
1 0 6 1472-1534 641 (16-31)
1 1 6 1472-1534 641 (16-31)
GTIC1
01 0 0 16 1344-1406 896 (0-15)
0 1 16 1344-1406 896 (0-15)
1 0 16 1600-1662 896 (0-15)
1 1 16 1600-1662 896 (0-15)
02 0 0 18 1664-1726 896 (16-31)
0 1 18 1664-1726 896 (16-31)
1 0 18 1728-1790 896 (16-31)
1 1 18 1728-1790 896 (16-31)
03 0 0 20 1792-1854 897 (0-15)
0 1 20 1792-1854 897 (0-15)
1 0 20 1856-1918 897 (0-15)
1 1 20 1856-1918 897 (0-15)
Table 6 ET indexes in BSC3i 1000/2000 (ETSI ETS2, two active and two standby STM-1)
DN9812243 21
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
04 0 0 22 1920-1982 897 (16-31)
0 1 22 1920-1982 897 (16-31)
1 0 22 1984-2046 897 (16-31)
1 1 22 1984-2046 897 (16-31)
Slot STM-1 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ETSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 64-126 640 (0-15)
0 1 0 64-126 640 (0-15)
02 0 0 2 192-254 640 (16-31)
0 1 2 192-254 640 (16-31)
03 0 0 4 320-382 641 (0-15)
0 1 4 320-382 641 (0-15)
04 0 0 6 448-510 641 (16-31)
0 1 6 448-510 641 (16-31)
05 0 0 8 1088-1150 642 (0-15)
0 1 8 1088-1150 642 (0-15)
06 0 0 10 1216-1278 642 (16-31)
0 1 10 1216-1278 642 (16-31)
07 0 0 12 1408-1470 643 (0-15)
0 1 12 1408-1470 643 (0-15)
08 0 0 14 1472-1534 643 (16-31)
0 1 14 1472-1534 643 (16-31)
GTIC1
01 0 0 16 1344-1406 896 (0-15)
0 1 16 1344-1406 896 (0-15)
02 0 0 18 1600-1662 896 (16-31)
0 1 18 1600-1662 896 (16-31)
Table 7 ET indexes in BSC3i 1000/2000 (ETSI ETS2, one active and one standby STM-1)
Slot STM-1 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ETSI)
Control PCM (TSLs)
Table 6 ET indexes in BSC3i 1000/2000 (ETSI ETS2, two active and two standby STM-1) (Cont.)
22 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
03 0 0 20 1664-1726 897 (0-15)
0 1 20 1664-1726 897 (0-15)
04 0 0 22 1728-1790 897 (16-31)
0 1 22 1728-1790 897 (16-31)
05 0 0 24 1792-1854 898 (0-15)
0 1 24 1792-1854 898 (0-15)
06 0 0 26 1856-1918 898 (16-31)
0 1 26 1856-1918 898 (16-31)
07 0 0 28 1920-1982 899 (0-15)
0 1 28 1920-1982 899 (0-15)
08 0 0 30 1984-2046 899 (16-31)
0 1 30 1984-2046 899 (16-31)
Slot OC-3 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 2048-2131 640 (0-15)
0 1 0 2048-2131 640 (0-15)
1 0 0 2132-2215 640 (0-15)
1 1 0 2132-2215 640 (0-15)
02 0 0 2 2216-2299 640 (16-31)
0 1 2 2216-2299 640 (16-31)
1 0 2 2300-2383 640 (16-31)
1 1 2 2300-2383 640 (16-31)
03 0 0 4 2384-2467 641 (0-15)
0 1 4 2384-2467 641 (0-15)
1 0 4 2468-2551 641 (0-15)
1 1 4 2468-2551 641 (0-15)
Table 8 ET indexes in BSC3i 1000/2000 (ANSI ETS2, two active and two standby OC-3)
Slot STM-1 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ETSI)
Control PCM (TSLs)
Table 7 ET indexes in BSC3i 1000/2000 (ETSI ETS2, one active and one standby STM-1) (Cont.)
DN9812243 23
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
04 0 0 6 2552-2635 641 (16-31)
0 1 6 2552-2635 641 (16-31)
1 0 6 2636-2719 641 (16-31)
1 1 6 2636-2719 641 (16-31)
GTIC1
01 0 0 16 2720-2803 896 (0-15)
0 1 16 2720-2803 896 (0-15)
1 0 16 2804-2887 896 (0-15)
1 1 16 2804-2887 896 (0-15)
02 0 0 18 2888-2971 896 (16-31)
0 1 18 2888-2971 896 (16-31)
1 0 18 2972-3055 896 (16-31)
1 1 18 2972-3055 896 (16-31)
03 0 0 20 3056-3139 897 (0-15)
0 1 20 3056-3139 897 (0-15)
1 0 20 3140-3223 897 (0-15)
1 1 20 3140-3223 897 (0-15)
04 0 0 22 3224-3307 897 (16-31)
0 1 22 3224-3307 897 (16-31)
1 0 22 3308-3391 897 (16-31)
1 1 22 3308-3391 897 (16-31)
Slot OC-3 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 2048-2131 640 (0-15)
0 1 0 2048-2131 640 (0-15)
02 0 0 2 2132-2215 640 (16-31)
0 1 2 2132-2215 640 (16-31)
Table 9 ET indexes in BSC3i 1000/2000 (ANSI ETS2, one active and one standby OC-3)
Slot OC-3 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ANSI)
Control PCM (TSLs)
Table 8 ET indexes in BSC3i 1000/2000 (ANSI ETS2, two active and two standby OC-3) (Cont.)
24 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
03 0 0 4 2216-2299 641 (0-15)
0 1 4 2216-2299 641 (0-15)
04 0 0 6 2300-2383 641 (16-31)
0 1 6 2300-2383 641 (16-31)
05 0 0 8 2384-2467 642 (0-15)
0 1 8 2384-2467 642 (0-15)
06 0 0 10 2468-2551 642 (16-31)
0 1 10 2468-2551 642 (16-31)
07 0 0 12 2552-2635 643 (0-15)
0 1 12 2552-2635 643 (0-15)
08 0 0 14 2636-2719 643 (16-31)
0 1 14 2636-2719 643 (16-31)
GTIC1
01 0 0 16 2720-2803 896 (0-15)
0 1 16 2720-2803 896 (0-15)
02 0 0 18 2804-2887 896 (16-31)
0 1 18 2804-2887 896 (16-31)
03 0 0 20 2888-2971 897 (0-15)
0 1 20 2888-2971 897 (0-15)
04 0 0 22 2972-3055 897 (16-31)
0 1 22 2972-3055 897 (16-31)
05 0 0 24 3056-3139 898 (0-15)
0 1 24 3056-3139 898 (0-15)
06 0 0 26 3140-3223 898 (16-31)
0 1 26 3140-3223 898 (16-31)
07 0 0 28 3224-3307 899 (0-15)
0 1 28 3224-3307 899 (0-15)
08 0 0 30 3308-3391 899 (16-31)
0 1 30 3308-3391 899 (16-31)
Slot OC-3 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ANSI)
Control PCM (TSLs)
Table 9 ET indexes in BSC3i 1000/2000 (ANSI ETS2, one active and one standby OC-3) (Cont.)
DN9812243 25
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 64-126
192-254
2048-2131
2132-2215
640 (0-3)
1 0 1 64-126
192-254
2048-2131
2132-2215
640 (0-3)
02 0 2 4 320-382
448-510
2216-2299
2300-2383
640 (16-19)
1 2 5 320-382
448-510
2216-2299
2300-2383
640 (16-19)
03 0 4 8 1088-1150
1216-1278
2384-2467
2468-2551
641 (0-3)
1 4 9 1088-1150
1216-1278
2384-2467
2468-2551
641 (0-3)
04 0 6 12 1408-1470
1472-1534
2552-2635
2636-2719
641 (16-19)
1 6 13 1408-1470
1472-1534
2552-2635
2636-2719
641 (16-19)
GTIC1
01 0 16 32 1344-1406
1600-1662
2720-2803
2804-2887
896 (0-3)
1 16 33 1344-1406
1600-1662
2720-2803
2804-2887
896 (0-3)
02 0 18 36 1664-1726
1728-1790
2888-2971
2972-3055
896 (16-19)
1 18 37 1664-1726
1728-1790
2888-2971
2972-3055
896 (16-19)
03 0 20 40 1792-1854
1856-1918
3056-3139
3140-3223
897 (0-3)
1 20 41 1792-1854
1856-1918
3056-3139
3140-3223
897 (0-3)
04 0 22 44 1920-1982
1984-2046
3224-3307
3308-3391
897 (16-19)
1 22 45 1920-1982
1984-2046
3224-3307
3308-3391
897 (16-19)
Table 10 ETIP and ET indexes in BSC3i 1000/2000 when transmission redundancy is in use
26 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 64-126
192-254
2048-2131
2132-2215
640 (0-3)
02 0 2 4 320-382
448-510
2216-2299
2300-2383
640 (16-19)
03 0 4 8 1088-1150
1216-1278
2384-2467
2468-2551
641 (0-3)
04 0 6 12 1408-1470
1472-1534
2552-2635
2636-2719
641 (16-19)
05 0 9 18 1344-1406
1600-1662
2720-2803
2804-2887
642 (0-3)
06 0 11 22 1664-1726
1728-1790
2888-2971
2972-3055
642 (16-19)
07 0 13 26 1792-1854
1856-1918
3056-3139
3140-3223
643 (0-3)
08 0 15 30 1920-1982
1984-2046
3224-3307
3308-3391
643 (16-19)
GTIC1
01 0 1 2 64-126
192-254
2048-2131
2132-2215
896 (0-3)
02 0 3 6 320-382
448-510
2216-2299
2300-2383
896 (16-19)
03 0 5 10 1088-1150
1216-1278
2384-2467
2468-2551
897 (0-3)
04 0 7 14 1408-1470
1472-1534
2552-2635
2636-2719
897 (16-19)
05 0 8 16 1344-1406
1600-1662
2720-2803
2804-2887
898 (0-3)
06 0 10 20 1664-1726
1728-1790
2888-2971
2972-3055
898 (16-19)
07 0 12 24 1792-1854
1856-1918
3056-3139
3140-3223
899 (0-3)
08 0 14 28 1920-1982
1984-2046
3224-3307
3308-3391
899 (16-19)
Table 11 ETIP and ET indexes in BSC3i 1000/2000 when HW redundancy is in use
DN9812243 27
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
10 0 0 0 64-126
192-254
2048-2131
2132-2215
392 (0-3)
1 0 1 64-126
192-254
2048-2131
2132-2215
392 (0-3)
11 0 2 4 1536-1598
1600-1662
2216-2299
2300-2383
392 (16-19)
1 2 5 1536-1598
1600-1662
2216-2299
2300-2383
392 (16-19)
12 0 4 8 1792-1854
1856-1918
2384-2467
2468-2551
393 (0-3)
1 4 9 1792-1854
1856-1918
2384-2467
2468-2551
393 (0-3)
13 0 6 12 1280-1342
1344-1406
2552-2635
2636-2719
393 (16-19)
1 6 13 1280-1342
1344-1406
2552-2635
2636-2719
393 (16-19)
GTIC1
10 0 16 32 1920-1982
1984-2046
2720-2803
2804-2887
384 (0-3)
1 16 33 1920-1982
1984-2046
2720-2803
2804-2887
384 (0-3)
11 0 18 36 768-830
832-894
2888-2971
2972-3055
384 (16-19)
1 18 37 768-830
832-894
2888-2971
2972-3055
384 (16-19)
12 0 20 40 1024-1086
1088-1150
3056-3139
3140-3223
385 (0-3)
1 20 41 1024-1086
1088-1150
3056-3139
3140-3223
385 (0-3)
13 0 22 44 512-574
576-638
3224-3307
3308-3391
385 (16-19)
1 22 45 512-574
576-638
3224-3307
3308-3391
385 (16-19)
Table 12 ETIP and ET indexes in new delivery Flexi BSC when transmission redun-dancy is in use
28 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 64-126
192-254
2048-2131
2132-2215
640 (0-3)
1 0 1 64-126
192-254
2048-2131
2132-2215
640 (0-3)
02 0 2 4 320-382
448-510
2216-2299
2300-2383
640 (16-19)
1 2 5 320-382
448-510
2216-2299
2300-2383
640 (16-19)
03 0 4 8 1088-1150
1216-1278
2384-2467
2468-2551
641 (0-3)
1 4 9 1088-1150
1216-1278
2384-2467
2468-2551
641 (0-3)
04 0 6 12 1408-1470
1472-1534
2552-2635
2636-2719
641 (16-19)
1 6 13 1408-1470
1472-1534
2552-2635
2636-2719
641 (16-19)
GTIC1
01 0 16 32 1344-1406
1600-1662
2720-2803
2804-2887
896 (0-3)
1 16 33 1344-1406
1600-1662
2720-2803
2804-2887
896 (0-3)
02 0 18 36 1664-1726
1728-1790
2888-2971
2972-3055
896 (16-19)
1 18 37 1664-1726
1728-1790
2888-2971
2972-3055
896 (16-19)
03 0 20 40 1792-1854
1856-1918
3056-3139
3140-3223
897 (0-3)
1 20 41 1792-1854
1856-1918
3056-3139
3140-3223
897 (0-3)
04 0 22 44 1920-1982
1984-2046
3224-3307
3308-3391
897 (16-19)
1 22 45 1920-1982
1984-2046
3224-3307
3308-3391
897 (16-19)
Table 13 ETIP and ET indexes in upgraded Flexi BSC when transmission redun-dancy is in use
DN9812243 29
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
10 0 0 0 64-126
192-254
2048-2131
2132-2215
392 (0-3)
11 0 2 4 1536-1598
1600-1662
2216-2299
2300-2383
392 (16-19)
12 0 4 8 1792-1854
1856-1918
2384-2467
2468-2551
393 (0-3)
13 0 6 12 1280-1342
1344-1406
2552-2635
2636-2719
393 (16-19)
14 0 9 18 1920-1982
1984-2046
2720-2803
2804-2887
394 (0-3)
15 0 11 22 768-830
832-894
2888-2971
2972-3055
394 (16-19)
16 0 13 26 1024-1086
1088-1150
3056-3139
3140-3223
395 (0-3)
17 0 15 30 512-574
576-638
3224-3307
3308-3391
395 (16-19)
GTIC1
10 0 1 2 64-126
192-254
2048-2131
2132-2215
384 (0-3)
11 0 3 6 1536-1598
1600-1662
2216-2299
2300-2383
384 (16-19)
12 0 5 10 1792-1854
1856-1918
2384-2467
2468-2551
385 (0-3)
13 0 7 14 1280-1342
1344-1406
2552-2635
2636-2719
385 (16-19)
14 0 8 16 1920-1982
1984-2046
2720-2803
2804-2887
386 (0-3)
15 0 10 20 768-830
832-894
2888-2971
2972-3055
386 (16-19)
16 0 12 24 1024-1086
1088-1150
3056-3139
3140-3223
387 (0-3)
17 0 14 28 512-574
576-638
3224-3307
3308-3391
387 (16-19)
Table 14 ETIP and ET indexes in new delivery Flexi BSC when HW redundancy is in use
30 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 64-126
192-254
2048-2131
2132-2215
640 (0-3)
02 0 2 4 320-382
448-510
2216-2299
2300-2383
640 (16-19)
03 0 4 8 1088-1150
1216-1278
2384-2467
2468-2551
641 (0-3)
04 0 6 12 1408-1470
1472-1534
2552-2635
2636-2719
641 (16-19)
05 0 9 18 1344-1406
1600-1662
2720-2803
2804-2887
642 (0-3)
06 0 11 22 1664-1726
1728-1790
2888-2971
2972-3055
642 (16-19)
07 0 13 26 1792-1854
1856-1918
3056-3139
3140-3223
643 (0-3)
08 0 15 30 1920-1982
1984-2046
3224-3307
3308-3391
643 (16-19)
GTIC1
01 0 1 2 64-126
192-254
2048-2131
2132-2215
896 (0-3)
02 0 3 6 320-382
448-510
2216-2299
2300-2383
896 (16-19)
03 0 5 10 1088-1150
1216-1278
2384-2467
2468-2551
897 (0-3)
04 0 7 14 1408-1470
1472-1534
2552-2635
2636-2719
897 (16-19)
05 0 8 16 1344-1406
1600-1662
2720-2803
2804-2887
898 (0-3)
06 0 10 20 1664-1726
1728-1790
2888-2971
2972-3055
898 (16-19)
07 0 12 24 1792-1854
1856-1918
3056-3139
3140-3223
899 (0-3)
08 0 14 28 1920-1982
1984-2046
3224-3307
3308-3391
899 (16-19)
Table 15 ETIP and ET indexes in upgraded Flexi BSC when HW redundancy is in use
DN9812243 31
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
10 0 0 0 0 64-126 2048-2131 392 (0-15)
0 1 0 1 64-126 2048-2131 392 (0-15)
1 0 0 2 192-254 2132-2215 392 (0-15)
1 1 0 3 192-254 2132-2215 392 (0-15)
11 0 0 2 8 1536-1598 2216-2299 392 (16-31)
0 1 2 9 1536-1598 2216-2299 392 (16-31)
1 0 2 10 1600-1662 2300-2383 392 (16-31)
1 1 2 11 1600-1662 2300-2383 392 (16-31)
12 0 0 4 16 1792-1854 2384-2467 393 (0-15)
0 1 4 17 1792-1854 2384-2467 393 (0-15)
1 0 4 18 1856-1918 2468-2551 393 (0-15)
1 1 4 19 1856-1918 2468-2551 393 (0-15)
13 0 0 6 24 1280-1342 2552-2635 393 (16-31)
0 1 6 25 1280-1342 2552-2635 393 (16-31)
1 0 6 26 1344-1406 2636-2719 393 (16-31)
1 1 6 27 1344-1406 2636-2719 393 (16-31)
GTIC1
10 0 0 16 64 1920-1982 2720-2803 384 (0-15)
0 1 16 65 1920-1982 2720-2803 384 (0-15)
1 0 16 66 1984-2046 2804-2887 384 (0-15)
1 1 16 67 1984-2046 2804-2887 384 (0-15)
11 0 0 18 72 768-830 2888-2971 384 (16-31)
0 1 18 73 768-830 2888-2971 384 (16-31)
1 0 18 74 832-894 2972-3055 384 (16-31)
1 1 18 75 832-894 2972-3055 384 (16-31)
12 0 0 20 80 1024-1086 3056-3139 385 (0-15)
0 1 20 81 1024-1086 3056-3139 385 (0-15)
1 0 20 82 1088-1150 3140-3223 385 (0-15)
1 1 20 83 1088-1150 3140-3223 385 (0-15)
Table 16 ET indexes in new delivery Flexi BSC when transmission redundancy is in use
32 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
13 0 0 22 88 512-574 3224-3307 385 (16-31)
0 1 22 89 512-574 3224-3307 385 (16-31)
1 0 22 90 576-638 3308-3391 385 (16-31)
1 1 22 91 576-638 3308-3391 385 (16-31)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
Table 16 ET indexes in new delivery Flexi BSC when transmission redundancy is in use (Cont.)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 0 64-126 2048-2131 640 (0-3)
0 1 0 1 64-126 2048-2131 640 (0-3)
1 0 0 2 192-254 2132-2215 640 (0-3)
1 1 0 3 192-254 2132-2215 640 (0-3)
02 0 0 2 8 320-382 2216-2299 640 (16-19)
0 1 2 9 320-382 2216-2299 640 (16-19)
1 0 2 10 448-510 2300-2383 640 (16-19)
1 1 2 11 448-510 2300-2383 640 (16-19)
03 0 0 4 16 1088-1150 2384-2467 641 (0-3)
0 1 4 17 1088-1150 2384-2467 641 (0-3)
1 0 4 18 1216-1278 2468-2551 641 (0-3)
1 1 4 19 1216-1278 2468-2551 641 (0-3)
04 0 0 6 24 1408-1470 2552-2635 641 (16-19)
0 1 6 25 1408-1470 2552-2635 641 (16-19)
1 0 6 26 1472-1534 2636-2719 641 (16-19)
1 1 6 27 1472-1534 2636-2719 641 (16-19)
GTIC1
01 0 0 16 64 1344-1406 2720-2803 896 (0-3)
0 1 16 65 1344-1406 2720-2803 896 (0-3)
1 0 16 66 1600-1662 2804-2887 896 (0-3)
1 1 16 67 1600-1662 2804-2887 896 (0-3)
Table 17 ET indexes in upgraded Flexi BSC when transmission redundancy is in use
DN9812243 33
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
02 0 0 18 72 1664-1726 2888-2971 896 (16-19)
0 1 18 73 1664-1726 2888-2971 896 (16-19)
1 0 18 74 1728-1790 2972-3055 896 (16-19)
1 1 18 75 1728-1790 2972-3055 896 (16-19)
03 0 0 20 80 1792-1854 3056-3139 897 (0-3)
0 1 20 81 1792-1854 3056-3139 897 (0-3)
1 0 20 82 1856-1918 3140-3223 897 (0-3)
1 1 20 83 1856-1918 3140-3223 897 (0-3)
04 0 0 22 88 1920-1982 3224-3307 897 (16-19)
0 1 22 89 1920-1982 3224-3307 897 (16-19)
1 0 22 90 1984-2046 3308-3391 897 (16-19)
1 1 22 91 1984-2046 3308-3391 897 (16-19)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
Table 17 ET indexes in upgraded Flexi BSC when transmission redundancy is in use (Cont.)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
10 0 0 0 0 64-126 2048-2131 392 (0-15)
1 0 0 2 192-254 2132-2215 392 (0-15)
11 0 0 2 8 1536-1598 2216-2299 392 (16-31)
1 0 2 10 1600-1662 2300-2383 392 (16-31)
12 0 0 4 16 1792-1854 2384-2467 393 (0-15)
1 0 4 18 1856-1918 2468-2551 393 (0-15)
13 0 0 6 24 1280-1342 2552-2635 393 (16-31)
1 0 6 26 1344-1406 2636-2719 393 (16-31)
14 0 0 9 36 1920-1982 2720-2803 394 (0-15)
1 0 9 38 1984-2046 2804-2887 394 (0-15)
15 0 0 11 44 768-830 2888-2971 394 (16-31)
1 0 11 46 832-894 2972-3055 394 (16-31)
16 0 0 13 52 1024-1086 3056-3139 395 (0-15)
1 0 13 54 1088-1150 3140-3223 395 (0-15)
Table 18 ET indexes in new delivery Flexi BSC cartridges when HW redundancy is in use
34 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
17 0 0 15 60 512-574 3224-3307 395 (16-31)
1 0 15 62 576-638 3308-3391 395 (16-31)
GTIC1
10 0 0 1 4 64-126 2048-2131 384 (0-15)
1 0 1 6 192-254 2132-2215 384 (0-15)
11 0 0 3 12 1536-1598 2216-2299 384 (16-31)
10 0 3 14 1600-1662 2300-2383 384 (16-31)
12 0 0 5 20 1792-1854 2384-2467 385 (0-15)
1 0 5 22 1856-1918 2468-2551 385 (0-15)
13 0 0 7 28 1280-1342 2552-2635 385 (16-31)
1 0 7 30 1344-1406 2636-2719 385 (16-31)
14 0 0 8 32 1920-1982 2720-2803 386 (0-15)
1 0 8 34 1984-2046 2804-2887 386 (0-15)
15 0 0 10 40 768-830 2888-2971 386 (16-31)
1 0 10 42 832-894 2972-3055 386 (16-31)
16 0 0 12 48 1024-1086 3056-3139 387 (0-15)
1 0 12 50 1088-1150 3140-3223 387 (0-15)
17 0 0 14 56 512-574 3224-3307 387 (16-31)
1 0 14 58 576-638 3308-3391 387 (16-31)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
Table 18 ET indexes in new delivery Flexi BSC cartridges when HW redundancy is in use (Cont.)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 0
01 0 0 0 0 64-126 2048-2131 640 (0-3)
1 0 0 2 192-254 2132-2215 640 (0-3)
02 0 0 2 8 320-382 2216-2299 640 (16-19)
1 0 2 10 448-510 2300-2383 640 (16-19)
03 0 0 4 16 1088-1150 2384-2467 641 (0-3)
1 0 4 18 1216-1278 2468-2551 641 (0-3)
Table 19 ET indexes in upgraded Flexi BSC cartridges when HW redundancy is in use
DN9812243 35
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
04 0 0 6 24 1408-1470 2552-2635 641 (16-19)
1 0 6 26 1472-1534 2636-2719 641 (16-19)
05 0 0 9 36 1344-1406 2720-2803 642 (0-3)
1 0 9 38 1600-1662 2804-2887 642 (0-3)
06 0 0 11 44 1664-1726 2888-2971 642 (16-19)
1 0 11 46 1728-1790 2972-3055 642 (16-19)
07 0 0 13 52 1792-1854 3056-3139 643 (0-3)
1 0 13 54 1856-1918 3140-3223 643 (0-3)
08 0 0 15 60 1920-1982 3224-3307 643 (16-19)
1 0 15 62 1984-2046 3308-3391 643 (16-19)
GTIC1
01 0 0 1 4 64-126 2048-2131 896 (0-3)
1 0 1 6 192-254 2132-2215 896 (0-3)
02 0 0 3 12 320-382 2216-2299 896 (16-19)
10 0 3 14 448-510 2300-2383 896 (16-19)
03 0 0 5 20 1088-1150 2384-2467 897 (0-3)
1 0 5 22 1216-1278 2468-2551 897 (0-3)
04 0 0 7 28 1408-1470 2552-2635 897 (16-19)
1 0 7 30 1472-1534 2636-2719 897 (16-19)
05 0 0 8 32 1344-1406 2720-2803 898 (0-3)
1 0 8 34 1600-1662 2804-2887 898 (0-3)
06 0 0 10 40 1664-1726 2888-2971 898 (16-19)
1 0 10 42 1728-1790 2972-3055 898 (16-19)
07 0 0 12 48 1792-1854 3056-3139 899 (0-3)
1 0 12 50 1856-1918 3140-3223 899 (0-3)
08 0 0 14 56 1920-1982 3224-3307 899 (16-19)
1 0 14 58 1984-2046 3308-3391 899 (16-19)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
Table 19 ET indexes in upgraded Flexi BSC cartridges when HW redundancy is in use (Cont.)
36 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
Figure 5 ET cartridges in the BSCC cabinet of BSC3i 1000
PDFU PDFU
DN0671322
CPGO
BSCC
CPETx CPRJ45-A
FTRB 1FTRB 0
FTRB 3FTRB 2
5
4
3
2
1
00 6
FRONT VIEW
30
GS
W2
KB
0
GS
W2
KB
186
CLO
C
30
MCMU0
MCMU1
OMU
6
4 80
BCSU0
BCSU1
BCSU2
4 80
BCSU3
BCSU4
BCSU5
0 2
ET
C0
ET
C1
10
LA
NU
0
LA
NU
1
CL
AC
0
GTIC0
GTIC1
4 96
4
3
2
1
0
CPETx
CPETx
CPETx
CPETx
CPETx
DN9812243 37
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Figure 6 ET cartridges in the BSCD extension cabinet of BSC3i 2000
PDFU PDFU
DN0671319
CPETx
BSCD
CPETx
FTRB 1FTRB 0
FTRB 3FTRB 2
5
4
3
2
1
0
0 6
FRONT VIEW
3
10
4 80
BCSU6
BCSU7
4 80
BCSU8
BCSU9
BCSU10
0
CLA
C1
ETC2
ETC3
ETC4
ETC5
LA
NU
3
LA
NU
2
30 6 9
6
38 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
Figure 7 ET cartridges in the new delivery Flexi BSC
PDFU 0PDFU-B
DN70590321
FTRB 1FTRB 0
FTRB 3FTRB 2
5
4
3
2
1
00 6
FRONT VIEW
30
GSW2KB-A0
96
4 80
BCSU0
OMU
BCSU3
BCSU5
0 4 96
4
0
CPETx
GTIC0
ETC0
ETC1 C
LS
0
GSW2KB-A1
GTIC1
ETC2
ETC3 C
LS
1
30 96
PDFU 1PDFU-B
6
MC
MU
0
MC
MU
1
CPETx
CPETx
1
2
3
CPETx
CPETx
0 4 96
BCSU1
LA
NU
0
BCSU4
BCSU6
BCSU2
LA
NU
1
BSCC
CPRJ45-ACPGO/CPETx
CPETx CPETx
DN9812243 39
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Figure 8 ET cartridges in the upgraded Flexi BSC
TCSM3i for combined BSC/TCSM installationThe TCSM3i for combined BSC/TCSM installation refers to a way to configure TCSM3i by equipping TCSM3i with a BSC3i or Flexi BSC. The combined BSC/TCSM consists of one BSC3i 1000/2000/upgraded or new delivery Flexi BSC cabinet (also called master BSC) and one TCSM3i cabinet.
Note that when two or more TCSM3i cabinets are used the master BSC needs to be BSC3i 1000 or Flexi BSC.
PDFUPDFU
CPGOT0.8
BSCC
CPETxT0.0
CPRJ45-AT0.4
FTRB 1 FTRB 0
FTRB 3 FTRB 2
5
4
3
2
1
006
Rear view
3 0
GSW2KB0
GSW2KB1
8 6
CL
OC
3 0
MCMU0
MCMU1
OMU
6
48 0
BCSU0
BCSU1
BCSU2
48 0
BCSU3
BCSU4
BCSU5
0
LA
NU
0
LA
NU
1
10
CL
AC
0
GTIC0
GTIC1
49 6
4
3
2
1
0
CPETx
CPETx
CPETx
CPETx
CPETx
BCSU6
DN70623936
40 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
The A interface is implemented by using the STM-1/OC-3 (SDH/SONET) or IP/Ethernet (GigE) interfaces instead of the ET16 (E1/T1) interface. Furthermore, the ET16 units in BSC's and TCSM3i's Ater interface are not used in this configuration.
Two duplicated hotlink cables are used between the BSC and the TCSM3i cabinet. In this application each hotlink cable carries 48 2Mbit/s PCM lines. The capacity of one STM-1 interface is 63 E1 PCMs and one OC-3 interface 84 T1 PCMs. BSC software treats STM-1/OC-3 interfaces as normal E1/T1 PCM lines.
The TCSM3i for combined BSC/TCSM installation with upgraded Flexi BSC brings some modifications to the structure of the BSC3i and TCSM3i: In BSC3i, the TCSA 0 cabinet replaces BCSU 6, the TCSA 1 cabinet replaces BCSU 5, and the TCSA 2 cabinet replaces BCSU 4 in the Group Switch GSW2KB. In TCSM3i, control PCM cables for STMUs/ETIPs both in the TCSA 0 and in the TCSA 1 cabinet are moved to other locations in the GSW2KB. Control PCM cables and control PCM allocations for STMUs/ETIPs in the TCSA 2 cabinet remain the same.
In the TCSM3i for combined BSC/TCSM installation, the ETIP1-A plug-in unit is con-nected to the BSC GSW by a hotlink and it is controlled by a separate LAPD link.
The capacity of one ETIP1-A plug-in unit in the TCSM3i for combined BSC/TCSM instal-lation environment is 126 E1 PCMs or 168 T1 PCMs.
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
GTIC 2
05 0 0 32 3392-3454
3392-3475
882 (0-15)
0 1 32 3392-3454
3392-3475
882 (0-15)
1 0 32 3456-3518
3476-3559
882 (0-15)
1 1 32 3456-3518
3476-3559
882 (0-15)
06 0 0 34 3520-3582
3560-3643
882 (16-31)
0 1 34 3520-3582
3560-3643
882 (16-31)
GTIC3
05 0 0 36 3584-3646
3644-3727
890 (0-15)
0 1 36 3584-3646
3644-3727
890 (0-15)
1 0 36 3648-3710
3728-3811
890 (0-15)
1 1 36 3648-3710
3728-3811
890 (0-15)
Table 20 ET indexes in TCSM3i for combined BSC/TCSM installation
DN9812243 41
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Figure 9 GTIC cartridges in TCSM3i for combined BSC/TCSM installation
06 0 0 38 3712-3774
3812-3895
890 (16-31)
0 1 38 3712-3774
3812-3895
890 (16-31)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
ET numbers (ETSI)
ET numbers (ANSI)
Control PCM (TSLs)
Table 20 ET indexes in TCSM3i for combined BSC/TCSM installation (Cont.)
CPGO
TCSA 2
FTRB 3FTRB 2
5
4
3
2
1
00 6
30 6
CL
AC
3
0
TC2C 13
6
60
0
9
6
FTRB 1FTRB 0
GTIC8
GTIC9
GTIC10
TC2C 12
TC2C 15TC2C 14
TC2C 17TC2C 16
CPGO
TCSA 1
FTRB 3FTRB 2
5
4
3
2
1
00 6
30 6
CLA
C2
0
TC2C 7
6
60
0
9
6
FTRB 1FTRB 0
GTIC5
GTIC6
GTIC7
TC2C 6
TC2C 9TC2C 8
TC2C 11TC2C 10
CPGO
TCSA 0
FTRB 3FTRB 2
5
4
3
2
1
00 6
30 6
CLA
C1
0
TC2C 1
6
60
0
9
6
FTRB 1FTRB 0
GTIC2
GTIC3
GTIC4
TC2C 0
TC2C 3TC2C 2
TC2C 5TC2C 4
PDFU 0 PDFU 1 PDFU 0 PDFU 1 PDFU 0 PDFU 1
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
TCSA 0 cabinet
GTIC 2
Table 21 ET indexes (ETS2) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when transmission redundancy is used
42 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
05 0 0 32 128 3392-3454 3392-3475
1280-1327 / 1664-1711
1586 (0-15) / 1714 (0-15)
0 1 32 129 3392-3454 3392-3475
1280-1327 / 1664-1711
1586 (0-15) / 1714 (0-15)
1 0 32 130 3456-3518 3476-3559
1280-1327 / 1664-1711
1586 (0-15) / 1714 (0-15)
1 1 32 131 3456-3518 3476-3559
1280-1327 / 1664-1711
1586 (0-15) / 1714 (0-15)
06 0 0 34 136 3520-3582 3560-3643
1280-1327 / 1664-1711
1586 (16-31) / 1714 (16-31)
0 1 34 137 3520-3582 3560-3643
1280-1327 / 1664-1711
1586 (16-31) / 1714 (16-31)
GTIC 3
05 0 0 36 144 3584-3646 3644-3727
1536-1583 / 1728-17775
1594 (0-15) / 1722 (0-15)
0 1 36 145 3584-3646 3644-3727
1536-1583 / 1728-17775
1594 (0-15) / 1722 (0-15)
1 0 36 146 3648-3710 3728-3811
1536-1583 / 1728-17775
1594 (0-15) / 1722 (0-15)
1 1 36 147 3648-3710 3728-3811
1536-1583 / 1728-17775
1594 (0-15) / 1722 (0-15)
06 0 0 38 152 3712-3774 3812-3895
1536-1583 / 1728-17775
1594 (16-31) / 1722 (16-31)
0 1 38 153 3712-3774 3812-3895
1536-1583 / 1728-17775
1594 (16-31) / 1722 (16-31)
TCSA 1 cabinet
GTIC 5
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 21 ET indexes (ETS2) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when transmission redundancy is used (Cont.)
DN9812243 43
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
05 0 0 40 160 3776-3838 3896-3979
768-815 / 1408-1455
882 (0-15) / 1458 (0-15)
0 1 40 161 3776-3838 3896-3979
768-815 / 1408-1455
882 (0-15) / 1458 (0-15)
1 0 40 162 3840-3902 3980-4063
768-815 / 1408-1455
882 (0-15) / 1458 (0-15)
1 1 40 163 3840-3902 3980-4063
768-815 / 1408-1455
882 (0-15) / 1458 (0-15)
06 0 0 42 168 3904-3966 4064-4147
768-815 / 1408-1455
882 (16-31) / 1458 (16-31)
0 1 42 169 3904-3966 4064-4147
768-815 / 1408-1455
882 (16-31) / 1458 (16-31)
GTIC 6
05 0 0 44 176 3968-4030 4148-4231
832-879 / 1472-1519
890 (0-15) / 1466 (0-15)
0 1 44 177 3968-4030 4148-4231
832-879 / 1472-1519
890 (0-15) / 1466 (0-15)
1 0 44 178 4032-4094 4232-4315
832-879 / 1472-1519
890 (0-15) / 1466 (0-15)
1 1 44 179 4032-4094 4232-4315
832-879 / 1472-1519
890 (0-15) / 1466 (0-15)
06 0 0 46 184 4096-4158 4316-4399
832-879 / 1472-1519
890 (16-31) / 1466 (16-
31)
0 1 46 185 4096-4158 4316-4399
832-879 / 1472-1519
890 (16-31) / 1466 (16-
31)
TCSA 2 cabinet
GTIC 8
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 21 ET indexes (ETS2) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when transmission redundancy is used (Cont.)
44 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
*) The 1st Ater PCM area and Control PCM numbers are for GSW2KB in upgraded Flexi BSC. The 2nd Ater PCM areas and Control PCMs are for GSW2KB-A in new delivery Flexi BSC.
05 0 0 48 192 4160-4222 4400-4483
1024-1071 / 1152-1199
1202 (0-15) / 1202 (0-15)
0 1 48 193 4160-4222 4400-4483
1024-1071 / 1152-1199
1202 (0-15) / 1202 (0-15)
1 0 48 194 4224-4286 4484-4567
1024-1071 / 1152-1199
1202 (0-15) / 1202 (0-15)
1 1 48 195 4224-4286 4484-4567
1024-1071 / 1152-1199
1202 (0-15) / 1202 (0-15)
06 0 0 50 200 4288-4350 4568-4651
1024-1071 / 1152-1199
1202 (16-31) / 1202 (16-31)
0 1 50 201 4288-4350 4568-4651
1024-1071 / 1152-1199
1202 (16-31) / 1202 (16-31)
GTIC 9
05 0 0 52 208 4352-4414 4652-4735
1152-1199 / 1216-1263
1210 (0-15) / 1210 (0-15)
0 1 52 209 4352-4414 4652-4735
1152-1199 / 1216-1263
1210 (0-15) / 1210 (0-15)
1 0 52 210 4416-4478 4736-4819
1152-1199 / 1216-1263
1210 (0-15) / 1210 (0-15)
1 1 52 211 4416-4478 4736-4819
1152-1199 / 1216-1263
1210 (0-15) / 1210 (0-15)
06 0 0 54 216 4480-4542 4820-4903
1152-1199 / 1216-1263
1210 (16-31) / 1210 (16-31)
0 1 54 217 4480-4542 4820-4903
1152-1199 / 1216-1263
1210 (16-31) / 1210 (16-31)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 21 ET indexes (ETS2) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when transmission redundancy is used (Cont.)
DN9812243 45
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
TCSA 0 cabinet
GTIC 2
05 0 0 32 128 3392-3454 3392-3475
1280-1327 / 1664-1711
1586 (0-15) / 1714 (0-15)
1 0 32 130 3456-3518 3476-3559
1280-1327 / 1664-1711
1586 (0-15) / 1714 (0-15)
06 0 0 34 136 3520-3582 3560-3643
1280-1327 / 1664-1711
1586 (16-31) / 1714 (16-31)
07 0 0 37 148 3584-3646 3644-3727
1536-1583 / 1728-17775
1587 (0-15) / 1715 (0-15)
1 0 37 150 3648-3710 3728-3811
1536-1583 / 1728-17775
1587 (0-15) / 1715 (0-15)
08 0 0 39 156 3712-3774 3812-3895
1536-1583 / 1728-17775
1587 (16-31) / 1715 (16-31)
GTIC 3
05 0 0 36 144 3584-3646 3644-3727
1536-1583 / 1728-17775
1594 (0-15) / 1722 (0-15)
1 0 36 146 3648-3710 3728-3811
1536-1583 / 1728-17775
1594 (0-15) / 1722 (0-15)
06 0 0 38 152 3712-3774 3812-3895
1536-1583 / 1728-17775
1594 (16-31) / 1722 (16-31)
07 0 0 33 132 3392-3454 3392-3475
1280-1327 /1664-1711
1595 (0-15) / 1723 (0-15)
1 0 33 134 3456-3518 3476-3559
1280-1327 /1664-1711
1595 (0-15) / 1723 (0-15)
08 0 0 35 140 3520-3582 3560-3643
1280…1327 /1664…1711
1595 (16-31) / 1723 (16-31)
Table 22 ET indexes (ETS2) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when HW redundancy is used
46 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
TCSA 1 cabinet
GTIC 5
05 0 0 40 160 3776-3838 3896-3979
768-815 / 1408-1455
882 (0-15) / 1458 (0-15)
1 0 40 162 3840-3902 3980-4063
768-815 / 1408-1455
882 (0-15) / 1458 (0-15)
06 0 0 42 168 3904-3966 4064-4147
768-815 / 1408-1455
882 (16-31) / 1458 (16-31)
07 0 0 45 180 3968-4030 4148-4231
832-879 / 1472-1519
883 (0-15) / 1459 (0-15)
1 0 45 182 4032-4094 4232-4315
832-879 / 1472-1519
883 (0-15) / 1459 (0-15)
08 0 0 47 188 4096-4158 4316-4399
832-879 / 1472-1519
883 (16-31) / 1459 (16-31)
GTIC 6
05 0 0 44 176 3968-4030 4148-4231
832-879 / 1472-1519
890 (0-15) / 1466 (0-15)
1 0 44 178 4032-4094 4232-4315
832-879 / 1472-1519
890 (0-15) / 1466 (0-15)
06 0 0 46 184 4096-4158 4316-4399
832-879 / 1472-1519
890 (16-31) / 1466 (16-
31)
07 0 0 41 164 3776-3838 3896-3979
768-815 / 1408-1455
891 (0-15) / 1467 (0-15)
1 0 41 166 3840-3902 3980-4063
768-815 / 1408-1455
891 (0-15) / 1467 (0-15)
08 0 0 43 172 3904-3966 4064-4147
768-815 / 1408-1455
891 (16-31) / 1467 (16-
31)
TCSA 2 cabinet
GTIC 8
05 0 0 48 192 4160-4222 4400-4483
1024-1071 / 1152-1199
1202 (0-15) / 1202 (0-15)
1 0 48 194 4224-4286 4484-4567
1024-1071 / 1152-1199
1202 (0-15) / 1202 (0-15)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 22 ET indexes (ETS2) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when HW redundancy is used (Cont.)
DN9812243 47
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
*) The 1st Ater PCM area and Control PCM numbers are for GSW2KB in upgraded Flexi BSC. The 2nd Ater PCM areas and Control PCMs are for GSW2KB-A in new delivery Flexi BSC.
06 0 0 50 200 4288-4350 4568-4651
1024-1071 / 1152-1199
1202 (16-31) / 1202 (16-31)
07 0 0 53 212 4352-4414 4652-4735
1152…1199 / 1216-1263
1203 (0-15) / 1203 (0-15)
1 0 53 214 4416-4478 4736-4819
1152-1199 / 1216-1263
1203 (0-15) / 1203 (0-15)
08 0 0 55 220 4480-4542 4820-4903
1152-1199 / 1216-1263
1203 (16-31) / 1203 (16-31)
GTIC 9
05 0 0 52 208 4352-4414 4652-4735
1152-1199 / 1216-1263
1210 (0-15) / 1210 (0-15)
1 0 52 210 4416-4478 4736-4819
1152-1199 / 1216-1263
1210 (0-15) / 1210 (0-15)
06 0 0 54 216 4480-4542 4820-4903
1152-1199 / 1216-1263
1210 (16-31) / 1210 (16-31)
07 0 0 49 196 4160-4222 4400-4483
1024-1071 / 1152-1199
1211 (0-15) / 1211 (0-15)
1 0 49 198 4224-4286 4484-4567
1024-1071 / 1152-1199
1211 (0-15) / 1211 (0-15)
08 0 0 51 204 4288-4350 4568-4651
1024-1071 / 1152-1199
1211 (16-31) / 1211 (16-31)
Slot STM-1/OC-3 inter-face of ETS2
Optical inter-face
STMU index
SET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 22 ET indexes (ETS2) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when HW redundancy is used (Cont.)
48 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
TCSA 0 cabinet
GTIC 2
05 0 32 64 3392-3454
3456-3518
3392-3475
3476-3559
1280-1327 / 1664-1711
1586 (0-3) / 1714 (0-3)
1 32 65 3392-3454
3456-3518
3392-3475
3476-3559
1280-1327 / 1664-1711
1586 (0-3) / 1714 (0-3)
06 0 34 68 3520-3582 3560-3643
1280-1327 / 1664-1711
1586 (16-19) / 1714 (16-19)
1 34 69 3520-3582 3560-3643
1280-1327 / 1664-1711
1586 (16-19) / 1714 (16-19)
GTIC 3
05 0 36 72 3584-3646
3648-3710
3644-3727
3728-3811
1536-1583 / 1728-17775
1594 (0-3) / 1722 (0-3)
1 36 73 3584-3646
3648-3710
3644-3727
3728-3811
1536-1583 / 1728-17775
1594 (0-3) / 1722 (0-3)
06 0 38 76 3712-3774 3812-3895
1536-1583 / 1728-17775
1594 (16-19) / 1722 (16-19)
1 38 77 3712-3774 3812-3895
1536-1583 / 1728-17775
1594 (16-19) / 1722 (16-19)
TCSA 1 cabinet
GTIC 5
Table 23 ET indexes (ETIP) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when transmission redundancy is used
DN9812243 49
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
05 0 40 80 3776-3838
3840-3902
3896-3979
3980-4063
768-815 / 1408-1455
882 (0-3) / 1458 (0-3)
1 40 81 3776-3838
3840-3902
3896-3979
3980-4063
768-815 / 1408-1455
882 (0-3) / 1458 (0-3)
06 0 42 84 3904-3966 4064-4147
768-815 / 1408-1455
882 (16-19) / 1458 (16-19)
1 42 85 3904-3966 4064-4147
768-815 / 1408-1455
882 (16-19) / 1458 (16-19)
GTIC 6
05 0 44 88 3968-4030
4032-4094
4148-4231
4232-4315
832-879 / 1472-1519
890 (0-3) / 1466 (0-3)
1 44 89 3968-4030
4032-4094
4148-4231
4232-4315
832-879 / 1472-1519
890 (0-3) / 1466 (0-3)
06 0 46 92 4096-4158 4316-4399
832-879 / 1472-1519
890 (16-19) / 1466 (16-19)
1 46 93 4096-4158 4316-4399
832-879 / 1472-1519
890 (16-19) / 1466 (16-19)
TCSA 2 cabinet
GTIC 8
05 0 48 96 4160-4222
4224-4286
4400-4483
4484-4567
1024-1071 / 1152-1199
1202 (0-3) / 1202 (0-3)
1 48 97 4160-4222
4224-4286
4400-4483
4484-4567
1024-1071 / 1152-1199
1202 (0-3) / 1202 (0-3)
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 23 ET indexes (ETIP) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when transmission redundancy is used (Cont.)
50 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
06 0 50 100 4288-4350 4568-4651
1024-1071 / 1152-1199
1202 (16-19) / 1202 (16-19)
1 50 101 4288-4350 4568-4651
1024-1071 / 1152-1199
1202 (16-19) / 1202 (16-19)
GTIC 9
05 0 52 104 4352-4414
4416-4478
4652-4735
4736-4819
1152-1199 / 1216-1263
1210 (0-3) / 1210 (0-3)
1 52 105 4352-4414
4416-4478
4652-4735
4736-4819
1152-1199 / 1216-1263
1210 (0-3) / 1210 (0-3)
06 0 54 108 4480-4542 4820-4903
1152-1199 / 1216-1263
1210 (16-19) / 1210 (16-19)
1 54 109 4480-4542 4820-4903
1152-1199 / 1216-1263
1210 (16-19) / 1210 (16-19)
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
TCSA 0 cabinet
GTIC 2
05 0 32 64 3392-3454
3456-3518
3392-3475
3476-3559
1280-1327 / 1664-1711
1586 (0-3) / 1714 (0-3)
Table 24 ET indexes (ETIP) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when HW redundancy is used
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 23 ET indexes (ETIP) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when transmission redundancy is used (Cont.)
DN9812243 51
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
06 0 34 68 3520-3582
3584-3646
3560-3643
3644-3727
1280-1327 / 1664-1711
1536-1583 / 1728-17775
1586 (16-19) / 1714 (16-19)
07 0 36 72 3648-3710
3712-3774
3728-3811
3812-3895
1536-1583 / 1728-17775
1587 (0-3) / 1715 (0-3)
GTIC 3
05 0 33 66 3392-3454
3456-3518
3392-3475
3476-3559
1280-1327 /1664-1711
1594 (0-3) / 1722 (0-3)
06 0 35 70 3520-3582
3584-3646
3560-3643
3644-3727
1280-1327 /1664-1711
1536-1583 / 1728-17775
1594 (16-19) / 1722 (16-19)
07 0 37 74 3648-3710
3712-3774
3728-3811
3812-3895
1536-1583 / 1728-17775
1595 (0-3) / 1723 (0-3)
TCSA 1 cabinet
GTIC 5
05 0 38 76 3776-3838
3840-3902
3896-3979
3980-4063
768-815 / 1408-1455
882 (0-3) / 1458 (0-3)
06 0 40 80 3904-3966
3968-4030
4064-4147
4148-4231
768-815 / 1408-1455
832-879 / 1472-1519
882 (16-19) / 1458 (16-19)
07 0 42 84 4032-4094
4096-4158
4232-4315
4316-4399
832-879 / 1472-1519
883 (0-3) / 1459 (0-3)
GTIC 6
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 24 ET indexes (ETIP) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when HW redundancy is used
52 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
05 0 39 78 3776-3838
3840-3902
3896-3979
3980-4063
768-815 / 1408-1455
890 (0-3) / 1466 (0-3)
06 0 41 82 3904-3966
3968-4030
4064-4147
4148-4231
768-815 / 1408-1455
832-879 / 1472-1519
890 (16-19) / 1466 (16-19)
07 0 43 86 4032-4094
4096-4158
4232-4315
4316-4399
832-879 / 1472-1519
891 (0-3) / 1467 (0-3)
TCSA 2 cabinet
GTIC 8
05 0 44 88 4160-4222
4224-4286
4400-4483
4484-4567
1024-1071 / 1152-1199
1202 (0-3) / 1202 (0-3)
06 0 46 92 4288-4350
4352-4414
4568-4651
4652-4735
1024-1071 / 1152-1199
1152…1199 / 1216-1263
1202 (16-19) / 1202 (16-19)
07 0 48 96 4416-4478
4480-4542
4736-4819
4820-4903
1152…1199 / 1216-1263
1203 (0-3) / 1203 (0-3)
GTIC 9
05 0 45 90 4160-4222
4224-4286
4400-4483
4484-4567
1024-1071 / 1152-1199
1210 (0-3) / 1210 (0-3)
06 0 47 94 4288-4350
4352-4414
4568-4651
4652-4735
1024-1071 / 1152-1199
1152…1199 / 1216-1263
1210 (16-19) / 1210 (16-19)
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 24 ET indexes (ETIP) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when HW redundancy is used
DN9812243 53
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
BSC3i 660BSC3i 660 can have up to two ET4C-B cartridges in basic configuration.
With the 256 PCM Bit Group Switch (GSWB), the two ET4C-B cartridges have space for 62 * (2*2) Mbit ET PCM's plug-in units in ETSI or 62 * (2*1.5) Mbit ET PCM's plug-in units in ANSI (32 pcs in ET4C 0, 30 pcs in ET4C 1). This makes it possible to have a maximum of 124 ET PCMs in one BSC3i 660. See figure ET4C-B cartridges with GSWB and ET2A/ET2A-T(B)/ET2E-S/SC/ET2E-T(B)/ET2E-TC(B) indexes in BSC3i 660.
With the 1024 PCM Bit Group Switch (GSW1KB), the two ET4C-B cartridges have space for 64 * (4*2) Mbit ET PCM's plug-in units in ETSI or 64 * (4*1.5) Mbit ET PCM's plug-in units in ANSI (32 pcs in ET4C 0 and 32 pcs in ET4C 1). This makes it possible to have a maximum of 256 ET PCMs in one BSC3i 660. See figure ET4C-B cartridges with GSW1KB and ET4A/ET4E/ET4E-C indexes in BSC3i 660.
With the GSW1KB Bit Group Switch it is also possible to mix ET2 and ET4 plug-in units in the BSC3i 660, so that each BSC3i 660 equipped with GSW1KB can have both ET2 and ET4 plug-in units with the restriction that one ET4C-B shelf must be equipped with either ET2 plug-in units or ET4 plug-in units. See figure ET4C-B cartridges with GSW1KB and ET2A/ET2A-T(B)/ET2E-S/SC/ET2E-T(B)/ET2E-TC(B) indexes in BSC3i 660.
07 0 49 98 4416-4478
4480-4542
4736-4819
4820-4903
1152…1199 / 1216-1263
1211 (0-3) / 1211 (0-3)
Slot GbE interface
ETIP index
EET number
ET numbers (ETSI)
ET numbers (ANSI)
Ater PCMs in GSW2KB / GSW2KB-A*)
Control PCM (TSLs ) in GSW2KB / GSW2KB-A *)
Table 24 ET indexes (ETIP) in TCSM3i for combined BSC/TCSM installation with upgraded and new delivery Flexi BSC when HW redundancy is used
54 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
Figure 10 ET4C-B cartridges with GSWB and ET2A/ET2A-T(B)/ET2E-S/SC/ET2E-T(B)/ET2E-TC(B) indexes in BSC3i 660
FTRB 0 FTRB 1
PDFU-A0
PDFU-A1
PDFU-A2
PDFU-A3
BSCC
GSWB1
GSWB0
CPRJ45 CPGOCPGO
BCSU 6
MCMU1
MCMU0
OMU
BCSU 0 BCSU 1 BCSU 2
FRONT VIEW
CL
S0
,1
BCSU 3 BCSU 4 BCSU 5
0
1
2
3
4FTRB 2 FTRB 3
TO
5
3233
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
ET4C 0
3435
3637
3839
4041
4243
4445
4647
4849
5051
5253
5455
5657
5859
6061
6263
9697
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
9899
100101
102103
104105
106107
108109
110111
112113
114115
116117
118119
120121
122123
124125
126127
ET4C 1
160161
162163
164165
166167
168169
170171
172173
174175
176177
178179
180181
182183
184185
186187
188189
190191
224225
226227
228229
230231
232233
234235
236237
238239
240241
242243
244245
246247
248249
250251
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
ET4C 1ET4C 0
GSWB:
GSWB:
GSWB:
GSWB:
DN9812243 55
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Figure 11 ET4C-B cartridges with GSW1KB and ET4A/ET4E/ET4E-C indexes in BSC3i 660
FTRB 0 FTRB 1
PDFU-A0
PDFU-A1
PDFU-A2
PDFU-A3
BSCC
GSW1KB1
GSW1KB0
CPRJ45 CPGOCPGO
BCSU 6
MCMU 1MCMU 0 OMU
BCSU 0 BCSU 1 BCSU 2
FRONT VIEW
CLS
0,1
BCSU 3 BCSU 4 BCSU 5
0
1
2
3
4
0 3 6 8
0 3 6 9
0 4 8
0 3 6
0 6
FTRB 2 FTRB 30 6
0 4 8
0 7
0 4 8
T0
5
256257258259
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
ET4C 0
ET4C 1
260261262263
264265266267
268269270271
272273274275
276277278279
280281282283
284285286287
288289290291
292293294295
296297298299
300301302303
304305306307
308309310311
312313314315
316317318319
384385386387
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
388389390391
392393394395
396397398399
400401402403
404405406407
408409410411
412413414415
416417418419
420421422423
424425426427
428429430431
432433434435
436437438439
440441442443
444445446447
320321322323
324325326327
328329330331
332333334335
336337338339
340341342343
344345346347
348349350351
352353354355
356357358359
360361362363
364365366367
368369370371
372373374375
376377378379
380381382383
448449450451
452453454455
456457458459
460461462463
464465466467
468469470471
472473474475
476477478479
480481482483
484485486487
488489490491
492493494495
496497498499
500501502503
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
ET4C 1(32oET4)
ET4C 0(32oET4)
GS
W1K
B
504505506507
508509510511
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
ET
4x
GS
W1K
BG
SW
1K
BG
SW
1K
B
56 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
Figure 12 ET4C-B cartridges with GSW1KB and ET2A/ET2A-T(B)/ET2E-S/SC/ET2E-T(B)/ET2E-TC(B) indexes in BSC3i 660
BSC2iThe BSC2i can have up to seven ET5C cartridges, each having space for 16 2Mbit ET PCM's plug-in units. This makes it possible to have a maximum of 112 2Mbit ET PCMs in one BSC2i; see the following figure.
FTRB 0 FTRB 1
PDFU-A0
PDFU-A1
PDFU-A2
PDFU-A3
BSCC
GSW1KB1
GSW1KB0
CPRJ45 CPGOCPGO
BCSU 6
MCMU 1MCMU 0 OMU
BCSU 0 BCSU 1 BCSU 2
FRONT VIEW
CL
S0
,1
BCSU 3 BCSU 4 BCSU 5
0
1
2
3
4
0 3 6 8
0 3 6 9
0 4 8
0 3 6
0 6
FTRB 2 FTRB 30 6
0 4 8
0 7
0 4 8
T0
5
256257
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
ET4C 0
ET4C 1
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
ET4C 1(32oET2)
ET4C 0(32oET2)
GS
W1
KB
:G
SW
1K
B:
GS
W1
KB
:
ET
2x
258259
260261
262263
264265
266267
268269
270271
272273
274275
276277
278279
280281
282283
284285
286287
384385
386387
388389
390391
392393
394395
396397
398399
400401
402403
404405
406407
408409
410411
412413
414415
320321
322323
324325
326327
328329
330331
332333
334335
336337
338339
340341
342343
344345
346347
348349
350351
448449
450451
452453
454455
456457
458459
460461
462463
464465
466467
468469
470471
472473
474475
476477
478479
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
ET
2x
GS
W1
KB
:
DN9812243 57
BSS Integration ET indexes in BSC
Id:0900d80580820876Confidential
Figure 13 ET5C cartridges and ET2E/ET2A indexes in BSC2i
BSCiIn BSCi (used only in the ETSI environment), there can be seven ET1C cartridges and two ET5C cartridges. Each ET1C cartridge can contain eight ET1E plug-in units and each ET5C cartridge can contain eight ET2E plug-in units, making it possible to have up to 88 2Mbit ET PCMs in one BSCi.
MCMU0 MCMU1
OMU
BCSU0
WDDC0
WDDC1
BCSU1
BCSU7
BCSU6BCSU5
BCSU4BCSU3
BCSU2
BCSU8
GSWB1GSWB0 CLOC0
CLAC0
PSA20_0PSFP0
PSA20_1PSFP1
PSA20_2PSFP2
PSA20_3PSFP3
ET5C0
BCBE BCEE
ET5C1
3233
3435
3637
3839
4849
5051
5253
5455
GSWB:
GSWB:
4041
4243
4445
4647
5657
5859
6061
6263
GSWB:
GSWB:
ET5C5
GSWB:
GSWB:
120121
122123
124125
126127
128129
130131
132133
134135
ET5C6
GSWB:
GSWB:
136137
138139
140141
142143
144145
146147
148149
150151
ET5C4
GSWB:
GSWB:
104105
106107
108109
110111
112113
114115
116117
118119
ET5C3
GSWB:
GSWB: 8081
8283
8485
8687
9697
9899
100101
102103
ET5C2
7273
7475
7677
7879
8889
9091
9293
9495
GSWB:
GSWB:
ET5C7
GSWB:
GSWB:
224225
226227
228229
230231
232233
234235
236237
238239
ET5C8
GSWB:
GSWB:
240241
242243
244245
246247
248249
250251
252253
254255
58 DN9812243
BSS Integration
Id:0900d80580820876Confidential
ET indexes in BSC
For an overview, see Overview of BSS integration.
Car-tridge
ET1
C0
ET1
C1
ET1
C2
ET1
C3
ET1
C4
ET1
C5
ET1
C6
ET1
C0
ET1
C1
PCM Index
32 40 48 56 72 80 88 96/97 112/113
33 41 49 57 73 81 89 98/99 114/115
34 42 50 58 74 82 90 100/101 116/117
35 43 51 59 75 83 91 102/103 118/119
36 44 52 60 76 84 92 104/105 120/121
37 45 53 61 77 85 93 106/107 122/123
38 46 54 62 78 86 94 108/109 124/125
39 47 55 63 79 87 95 110/111 126/127
Table 25 ET indexes with GSWB in BSCi
DN9812243 59
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
5 Creating the A interfaceIn this phase the MSC, the transcoder, and the BSC are configured to enable the MSC and the BSC to communicate properly with each other.
For more information on connecting a BSC to other core network elements, see Multi-point A Interface in BSC.
For an overview, see Overview of BSS integration.
5.1 Connecting the A interface ETEach A interface needs its own ET. The ETs used for the A interface must be the ones that supply synchronisation to the BSC's CLS units. There are three such ETs per BSC, and their default unit numbers are shown in the table below. It is possible to use any other ET for the synchronisation by changing the position of the corresponding synchro-nisation cable in the ET cartridge.
*RoHS compliant ET2A-TB, ET2E-TB and ET2E-TCB units are created to the equip-ment database as ET2A-T , ET2E-T and ET2E-TC.
Steps
1 Check that the ET is connected (WUP).ZWUP:<PCM numbers>;
If the ET is already connected, it has a controlling BCSU (Base Station Controller Sig-nalling Unit) and process info. The controlling process can be SC7PRB A interface, ABIPRB Abis interface, SI1PRB ISDN Abis interface, or ERATES Gb interface.
BSC type ET type GSW type Default synchronisation ETs
BSCi ET1E, ET1E-C, ET2E, ET2E-C, ET2E-S/SC, ET2E-T(B), ET2E-TC(B)*
GSWB 32,33,34
BSC2i ET2E/A, ET2E-C, ET2E-S/SC, ET2E-T(B), ET2A-T(B), ET2E-TC(B)*
GSWB 32,40,48
(only even ETs possible)
BSC3i ET2A, ET2E-S/SC, ET2E-T(B), ET2A-T(B), ET2E-TC(B)*
GSWB 32, 96, 160, 224
(only even ETs possible)
ET4A, ET4E, ET4E-C
GSW1KB
BSC3i 1000, BSC3i 2000
ET16 GSW2KB 512, 576, 528, 592
Flexi BSC ET16 GSW2KB-A 368, 640, 256, 624
Table 26 Default synchronisation ETs
60 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
Example: ZWUP:32&33&36;
EXECUTION STARTED
BSC VAPPU 2004-10-18 08:39:25
PCM COMP PROC INFO_1 INFO_2 INFO_3 ADD_INFO PAGE 1 32 BCSU SC7PRB ETPCM - - VIRTUAL_PCMS 32H 01B1H 0000H 0000H 0000H 1280 - 1281 33 BCSU ABIPRB ETPCM - - VIRTUAL_PCMS 32H 01BFH 0000H 0000H 0000H 1288 - 1295 36 BCSU ERATES ETPCM - - 32H 010AH 0000H 0000H 0000H
TOTAL OF 3 PCM CIRCUITS
COMMAND EXECUTED
2 To implement this step, choose one of the following alternatives:
a If ET is already connected
Then
Check that the ET is in WO state and restart the ET (USU).The state of the ET can be changed with command USC.
The ET must be restarted to ensure that the correct ET software is loaded into the unit.
ZUSU:ET,<pcm_index>,C=TOT;
Note that all ET's in the same plug-in unit will be restarted concurrently.
b If ET is not connected
Then
Connect the ET (WUC).ZWUC:ET,<unit index>:<plug-in unit type>,0:IF=A:BCSU,<bcsu index>;
*RoHS compliant ET2A-TB, ET2E-TB and ET2E-TCB units are created to the equip-ment database as ET2A-T , ET2E-T and ET2E-TC.
Parameter Explanation
plug-in unit type Type of the ET:
ETSI: ET1E, ET1E-C, ET2E, ET2E-C, ET2E-S, ET2E-SC, ET2E-T*, ET2E-TC*, ET4E, ET4E-C, or ET16
ANSI: ET2A, ET2A-T*, ET4A, or ET16
DN9812243 61
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
Note that you have to select the line interface (T1 or E1) in ET16 with a micro switch. For more information see ET16 C109519 in Jumper Settings of the Plug-in Units in BSC3i and in TCSM3i.
If the controlling BCSU is not already in WO-EX state, the state of the BCSU must be changed to WO-EX. Once the BCSU's state is WO-EX, the state of the ET can be changed to WO-EX, too.
t When using ET2E/A, ET2E-C, ET2E-S/SC, ET2E-T(B), ET2A-T(B), or ET2E-TC(B) plug-in units, connect the even-numbered ET before the odd-numbered.
When using ET4A, ET4E, ET4E-C, or ET16 plug-in units, first connect the first logical ET of the cartridge.
3 Check and change the functional modes for the ET if needed.The status of the frame alignment mode must be the same at both ends of the PCM line.
For ET1E cards the frame alignment mode is set by strapping.
For ET2E/A, ET2E-C, ET2E-S/SC, ET2E-T(B), ET2A-T(B), ET2E-TC(B), ET4A, ET4E, ET4E-C, or ET16 the frame alignment mode is set by MML. The frame alignment mode strapping in them is used only during the unit restart when the software cannot be loaded for some reason.
Steps
a Output the functional modes of the ET2E/A, ET2E-C, ET2E-S/SC, ET2E-T(B), ET2A-T(B), ET2E-TC(B), ET4A, ET4E, ET4E-C, or ET16 (ETSI: YEI, ANSI: YEH).
• ETSI:ZYEI:ET,<unit index>;
• ANSI:This means the values of the strappings to be programmed:ZYEH:<unit type>,<unit index>;
b Change the functional mode if needed (ETSI: YEC, ANSI: YEG).
• ETSI:ZYEC:ET,<unit index>:NORM,<frame alignment mode>;
• ANSI:Note that the T1 functional modes have to be the same at both ends of the T1 line.ZYEG:<unit type>,<unit index>:<superframe mode>,<line code type>,<outgoing signal level>;
Further informationNext, create the transcoder devices.
5.2 Connecting the optical A interfacePurposeThis section describes how to configure the A interface when STM-1/OC-3 optical trans-mission is used. STM-1/OC-3 interface is an optical interface to SDH network that
62 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
increases the connectivity of the network element. One STM-1 (ETSI) interface can carry 63 E1 PCMs and one OC-3 (ANSI) interface 84 T1 PCMs.
STM-1/OC-3 interfaces are implemented with ETS2 plug-in units, each of which can handle two interfaces.
For more information, see Configuring the STM-1/OC-3 interface in STM-1/OC-3 (SDH/SONET) Interface.
Steps
1 Create the cartridge, functional unit, ET groups and plug-in units for the ET groups.For detailed instructions and commands, see Creating and managing ETS2s in Creating and Managing BSC Hardware.
2 Connect the ET (WUC).ZWUC:<unit type>,<unit index>:<piu type>,<piu index>:IF=<interface>:<controlling unit type>,<controlling unit index>:;
Example: ETSI:
ZWUC:ET,64&&126:ETS2,0:IF=A:BCSU,1:;
ZWUC:ET,192&&254:ETS2,0:IF=A:BCSU,1:;
ANSI:
ZWUC:ET,2048&&2131:ETS2,0:IF=A:BCSU,1:;
ZWUC:ET,2132&&2215:ETS2,0:IF=A:BCSU,1:;
3 Check the ET configuration (YAI).ZYAI:<exchange terminal type>,<exchange terminal index>:;
Example: ZYAI:SET,0:;
4 Check the functional mode of exchange terminal (YEI or YEH).The mode should be the same at both ends of the connection. Check the current PDH frame alignment mode at the remote end of the connection and compare it to the current mode at the local end. In an ETSI environment, the default value of E1 frame alignment mode is CRC4. In an ANSI environment, the default value of T1 frame alignment mode is ESF .
ETSI:
ZYEI:<unit type>;
ANSI:
ZYEH:<unit type>;
DN9812243 63
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
5 Change the functional mode, if needed (YEC or YEG).ETSI:
ZYEC:<unit type>,<unit index>:<functional mode>,<frame alignment mode>:;
ANSI:
ZYEG:<unit type>,<unit index>:<superframe mode>;
5.3 Connecting the PWE interfacePurposeThis section describes how to connect the A interface when IP/Ethernet (GigE) trans-mission is used. The IP/Ethernet interfaces are implemented with ETIP plug-in units.
For more information, see Creating the unit connections in ETIP/PWT User Guide.
When there is no existing IP/Ethernet based Ater interface connection between BSC and TCSM3i, the user needs to configure BSC and TCSM3i locally. When you do this for the first time use one of the Ater interface master TR3E/TR3A/TR3T plug-in units, otherwise remote connections are not possible later.
Steps
1 Create the cartridge, functional unit, ET groups and plug-in units for the ET groups.For detailed instructions and commands, see Creating and managing ETIPs in Creating and Managing BSC Hardware.
2 Connect the ET (WUC).ZWUC:<unit type>,<unit index>:<piu type>,<piu index>:IF=<interface>:<controlling unit type>,<controlling unit index>:;
Example: ETSI:
ZWUC:ET,64&&126:ETIP1_A,0:IF=A:BCSU,1:;
ZWUC:ET,192&&254:ETIP1_A,0:IF=A:BCSU,1:;
ANSI:
ZWUC:ET,2048&&2131:ETIP1_A,0:IF=A:BCSU,1:;
ZWUC:ET,2132&&2215:ETIP1_A,0:IF=A:BCSU,1:;
5.4 Creating the transcoder devicesIn this phase the transcoder is configured. The transcoder is needed between the MSC and the BSC for speech compression. It compresses 64 kbit speech time slots coming from the MSC to 16 or 8 kbit speech time slots going to the BSC. Decompression is carried out in the opposite direction.
64 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
Choose one of the following procedures, depending on the type of TCSM and the type of configuration used.
5.4.1 Creating the TCSM3i
PurposeWhen the standalone TCSM3i is created into the BSC hardware database, its functional unit is TCSM and both transcoder types are controlled by the BSC via the LAPD link. The TCSM3i software is also kept in the BSC hard disks from where it can be down-loaded to the TCSM3i whenever necessary.
One transcoder based on TCSM3i hardware consists of one TR3E (ETSI), TR3A (ANSI), or TR3T (ETSI or ANSI) plug-in unit and either one ET16 or one ETIP plug-in unit (as Ater interface). ETP-A unit for the Packet Transport is included in the stand alone TCSM3i, also mixed with ET16 and ETIP plug-in units (as A interface).
In TCSM3i, both ET16 and ETIP plug-in units are equipped only with supervised TR3E/TR3A/TR3T units.
When IP/Ethernet (GigE) connections are used as Ater interfaces, Ater PCM cablings are delivered in a general optional set for ETIP used as Ater interface. The ETIP1-A plug-in unit on the Ater interface is always HW protected, so an optional set for HW pro-tection is always used in Ater interfaces for standalone TCSM3i with IP/Ethernet (GigE) interfaces
One TCSM3i can handle a maximum of four TC-PCMs on the A interface when 16 Kbit/s submultiplexing is used on Ater interface. 8 Kbit/s Ater submultiplexing is not supported by the TCSM3i.
One TCSM3i cabinet can contain up to 96 transcoder units in 6 cartridges as shown in the figure below. The same principles apply in both ET16 and ETIP configurations.
DN9812243 65
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
Figure 14 TCSM3i ET (ET16 or ETIP) units and transcoder units
For more information on TCSM3i cabinet configurations, please refer TCSM3i cabinet configuration and capacity.
As shown in the following table, a certain number of TR3E/TR3A/TR3T units act as masters who supervise the ET16 plug-in units. When the master TR3E/TR3A/TR3T plug-in units are taken into use, the ET16 plug-in units are also equipped.
TC2C 0
slots:
slots:
slots:
TR3E
1
TR3E
2
TR3E
3
TR3E
4
TR3E
5
TR3E
6
TR3E
7
TR3E
8
TR3E
9
TR3E
10
TR3E
11
TR3E
12
TR3E
13
TR3E
14
TR3E
15
TR3E
16
ET16
17 18 19
1 2 3 4
TC2C 1
TR3E
1
TR3E
2
TR3E
3
TR3E
4
TR3E
5
TR3E
6
TR3E
7
TR3E
8
TR3E
9
TR3E
10
TR3E
11
TR3E
12
TR3E
13
TR3E
14
TR3E
15
TR3E
16
ET16
17 18 19
5 6 7 8
ET16
TC2C 3
TR3E
1
TR3E
2
TR3E
3
TR3E
4
TR3E
5
TR3E
6
TR3E
7
TR3E
8
TR3E
9
TR3E
10
TR3E
11
TR3E
12
TR3E
13
TR3E
14
TR3E
15
TR3E
16
ET16
17 18 19
13 14 15 16
ET16
TC2C 2
TR3E
1
TR3E
2
TR3E
3
TR3E
4
TR3E
5
TR3E
6
TR3E
7
TR3E
8
TR3E
9
TR3E
10
TR3E
11
TR3E
12
TR3E
13
TR3E
14
TR3E
15
TR3E
16
ET16
17 18 19
9 10 11 12
TC2C 5
TR3E
1
TR3E
2
TR3E
3
TR3E
4
TR3E
5
TR3E
6
TR3E
7
TR3E
8
TR3E
9
TR3E
10
TR3E
11
TR3E
12
TR3E
13
TR3E
14
TR3E
15
TR3E
16
ET16
17 18 19
21 22 23 24
ET16
TC2C 4
TR3E
1
TR3E
2
TR3E
3
TR3E
4
TR3E
5
TR3E
6
TR3E
7
TR3E
8
TR3E
9
TR3E
10
TR3E
11
TR3E
12
TR3E
13
TR3E
14
TR3E
15
TR3E
16
ET16
17 18 19
17 18 19 20
ETC 0
1 2 3 4 5 6 7 8
ET16
ET16
ET16
ET16
ET16
ET16
ET16
ET16
1 5 9 13 17 19 21 23
slots:
ETC 1
1 2 3 4 5 6 7 8
ET16
ET16
ET16
ET16
ET16
ET16
ET16
ET16
2 4 6 8 10 12 14 16
ETC 2
1 2 3 4 5 6 7 8
ET16
ET16
ET16
ET16
ET16
ET16
ET16
ET16
3 7 11 15 18 20 22 24
Slot number Role when using ET16 Role when using ETIP
1 Cartridge master Cartridge master
2 Cabinet head master (only in cartridge 2.0)
Cabinet head master (only in cartridge 2.0)
3 - Ater ETIP master
4 - A ETIP master
Table 27 TR3E/TR3A/TR3T roles
66 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
* acts as a cartridge master when two BSCs are connected to one cartridge
To ensure that the TCSM3i capacity is fully exploited, its transcoding functions can be shared between several BSCs. This is achieved by connecting two BSCs to one TCSM3i cartridge. In this kind of configuration one BSC uses the first eight TR3E/TR3A/TR3T plug-in units and the other BSC the last eight TR3E/TR3A/TR3T plug-in units. Additional ET16 plug-in units must be installed to the TCSM3i for the second BSC Ater interface to the TCSM3i cartridge.
For more information on configuring ETIP plug-in unit and creating the IP/Ethernet (GigE) configuration, see ETIP/PWT User Guide.
Steps
1 Create the cabinet clock cartridge (WTC).ZWTC:<cartridge type>, coordinate of cartridge>:P1;
2 Create the TCSM3i cabinet (WTJ).ZWTJ:TCSA,1D:AL=1D1-0-4R1,PDFU=4;
3 Create the TCSM and ET cartridges (WTC).ZWTC:<cartridge type>,<coordinate of cartridge>:P1;
4 Create the TCSM unit (WTU).ZWTU:<unit identification>:<coordinate of cartridge>;
Note that the indexes of the BSC site ET and the TCSM have to be the same.
5 Create the TR3E/TR3A/TR3T plug-in units (WTP).ZWTP:TCSM,<unit index>:<piu type>,<piu index>,<track>::GENERAL,8,<PCM>,<TSL type>,<TSL>;
5 Master Master
7 - Ater ETIP master
8 - A ETIP master
9 Master* Master*
11 - Ater ETIP master
12 - A ETIP master
13 Master Master
15 - Ater ETIP master
16 - A ETIP master
Slot number Role when using ET16 Role when using ETIP
Table 27 TR3E/TR3A/TR3T roles (Cont.)
DN9812243 67
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
6 Create the ET16 or ETIP plug-in units (WTP).ZWTP:TCSM,<unit index>:<piu type>,0,1; (A interface ET)
ZWTP:TCSM,<unit index>:<piu type>,1,17; (Ater interface ET)
7 Set the number of through connected channels (WGS).ZWGS:<highway pcm>:<number of through connected channels>;
8 Create transcoder PCMs (WGC).ZWGC:<highway pcm number>,<tc_pcm number>:POOL=<transcoder pcm pool numbers>:BCSU,<controlling unit index>;
The table below shows which A-interface pools support which codecs and application software.
9 Connect the TR3E/TR3A/TR3T to the BSC (WUC).This command creates the LAPD link between the BSC and the TR3E/TR3A/TR3T. A circuit group DTCSM and the circuit to it are created at the same time.
ZWUC:TCSM,<unit index>:<piu type>,<piu index>;
10 Change the state of the TCSM3i to WO-EX (USC).This command automatically changes the state of the TCSM LAPD link to WO-EX. If the TCSM3i software does not exist or is different from that in the BSC, it is downloaded in this phase.
11 Check the state of the TCSM3i LAPD link (DTF).ZDTF:TCSM,<unit index>:OMU;
The transcoder has less PCM types than the BSC has pools. This results in the fact that when you are checking the PCM circuits from the transcoder end, the PCM types are different than the pools in the BSC.
Supported codecs and software Supported A-interface pools
FR, HR, EFR, AMR, 14.4D, AEC, TFO, NS, TTY
1 (FR), 3 (DR), 5 (EFR&FR), 7 (EFR&DR), 20 (EFR&DR&D144), 23 (AMR), 28 (EFR&DR&AMR&D144)
FR, HR, EFR, AMR, HSCSD, 14.4D, AEC, TFO, NS, TTY
10 (HS2), 21 (HS2&D144)
FR, HR, EFR, AMR, HSCSD, 14.4D, AEC, TFO, NS, TTY
13 (HS4), 22 (HS4&D144), 32 (EFR&DR&AMR&HS4&D144)
AMR-WB 37,38,40
Table 28 Possible combinations of circuit pools (TCSM3i)
68 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
12 Add through connected channels (WGA).ZWGA:<highway pcm circuit>:<tc_pcm circuit>;
13 Output and check the through connected channels (WGO).ZWGO:<highway pcm number>:<output mode>;
Further informationFor more detailed information on the commands, see Configuring the TCSM3i in Creating and Managing the BSC Hardware.
5.4.2 Creating TCSM3i for combined BSC/TCSM installationThe growing capacity of the BSC results in the increased transmission capacity between the BSC and the MSC. For example, the BSC3i 2000 has a capacity of 12000 erlangs. This means the user has to configure 99/124 PCM cables between the BSC and the transcoders, translating to 396/496 A-interface PCM cables. To avoid using such a huge number of PCM cables, synchronous transmission on optical media (cable) is intro-duced.
In the ETSI environment, synchronous transmission is standardised by Synchronous Digital Hierarchy (SDH). Interface to optical media is called STM-N, where N defines the transmission speed.
In ANSI environment synchronous transmission is standardised by SONET and inter-face is called OC-x, where x defines the transmission speed. One STM-1 interface can handle 63 E1 PCM's capacity and one OC-3 interface can handle 84 T1 PCM's capacity.
Figure 15 Configuration of the TCSM3i for combined BSC/TCSM installation
g For the details on TCSM3i combined upgrade procedure, please refer the SW Release documentation: BSC/TCSM HW implementation for combined installation.
Remote BSC is connected to master BSC by using traditional PCM cable
Remote BSC (A)Master BSCcabinet
TCSM3i cabinet
MSCET unit
ET unitPCM cable
STMU
STMU
STMU
Remote BSC (B) is connected to master BSC by using optical cable
Remote BSC (B)
TR3E PIU
Optical transmission
DN9812243 69
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
TCSM3i for combined BSC/TCSM implements same transcoding functionality and features as standalone version. It is possible to distribute TCSM3i's capacity between several BSCs. The BSC3i which is combined or installed together with the TCSM3i is called the Master BSC. A Remote BSC is located away from the TCSM3i and its Ater PCMs are connected to TCSM3i cabinet via Master BSC's E1/T1 PCM lines, optical STM-1/OC-3, or IP/Ethernet (GigE) connections.
1. Creating TCSM unit to Master BSCThe Master BSC must always be a BSC3i 1000, BSC3i 2000 or Flexi BSC.
2. Sharing TCSM3i for combined BSC/TCSM transcoding capacity to remote BSCA Remote BSC can be BSC3i 1000, BSC3i 2000, Flexi BSC, or even older models. If the remote BSC does not support IP/Ethernet (GigE) or optical interfaces, ET inter-faces can be used.If the BSC in a combined BSC/TCSM installation is BSC3i 1000, it is possible to install up to three TCSM3i cabinets. With Flexi BSC there can only be one TCSM3i cabinet.
The procedure below contains the ETSI command examples for creating the transcoder into the Master BSC. You can find more detailed information in the document BSC3i upgrade for combined BSC/TCSM in the release binder.
Steps
1 Create the CLAB.ZWTC:CLAC_B,1D1-0:;
ZWTU:CLAB,2:1D1-0;
ZWTP:CLAB,2:CLAB_S,0,3;
ZWTU:CLAB,3:1D1-0:;
ZWTP:CLAB,3:CLAB_S,1,4;
2 Create the TCSA cartridge.ZWTJ:TCSA,1D:AL=1D1-0-3R1,PDFU=2;
3 Create the STMU or ETIP.
a) Create the cartridge:ZWTC:GT4C_A,1D1-3:AL=1D1-0-2S3;
b) Create the functional unit:ZWTU:<STMU or ETIP>,32:1D1-3;
c) Create the plug-in unit:ZWTP:STMU,32:ETS2,0,5:LAPD,8,882,TSL,0&&15;orZWTP:ETIP,32:ETIP1_A,0,5:LAPD,8,882,TSL,0&&3;
d) Connect the plug-in unit:ZWUC:STMU,32:ETS2,0::BCSU,0;orZWUC:ETIP,32:ETIP1_A,0::BCSU,0;
e) Change the STMU state to WO-EX with the MML command USC.
70 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
4 Create the SBMUX.ZWTU:GSW,0:1D1-3:MAS=MCMU;
ZWTU:GSW,1:1D1-6:MAS=MCMU;
ZWTP:GSW,0,1D1-3:SBMUX_A,0,1;
ZWTP:GSW,1,1D1-6:SBMUX_A,0,1;
ZWTP:GSW,0,1D1-3:SBMUX_A,1,2;
ZWTP:GSW,1,1D1-6:SBMUX_A,1,2;
5 Create the TCSM unit.
a) Create the cartridge:ZWTC:TC2C_A,1D2-0:AL=1D1-0-2R3;
b) Create the functional unit:ZWTU:TCSM,1280:1D2-0;
c) Create the TR3E plug-in unit:ZWTP:TCSM,1280,1D2-0:TR3E,0,1::GENERAL,8,1280,TSL,1;
d) Create a LAPD link to the TR3E plug-in unit:ZWUC:TCSM,1280:TR3E,0:;After this link is created, this event information is sent to NetAct.
6 Create the A-interface ET units into the STMU or ETIP.
a) Create the functional units:ZWTU:ET,3392&&3454:1D1-3:UNIT=STMU,IND=32:IF=0;orZWTU:ET,3392&&3454:1D1-3:UNIT=ETIP,IND=32;Note that the ET range in ANSI is from 3392 to 3475.
b) Create the plug-in units into the ET unit:ZWTP:ET,3392&&3454:<ETS2 or ETIP1_A>,0,5:ETT00,8,3392&&3454,TSL,0;
c) Connect the ET units:ZWUC:ET,3392&&3454:<ETS2 or ETIP1_A>,0:IF=A:BCSU,0;
d) Change the ET state to WO-EX with the MML command USC.
7 Create transcoder configuration.
a) Set the number of through connections.ZWGS:1280:1;
b) Create the TC-PCM with the MML command WGC:ZWGC:1280,1:POOL=1:BCSU,1;ZWGC:1280,2:POOL=1:BCSU,4;ZWGC:1280,3:POOL=1:BCSU,5;ZWGC:1280,4:POOL=1:BCSU,6;
t The fifth TC-PCM can be used in ANSI environment.
c) Create the through connections.ZWGA:1280-30:1-24;
DN9812243 71
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
d) Change TCSM3i state from SE-NH to TE-EX with the MML command USC.e) The TR3E starts downloading its software from the BSC.
After successfully downloading software, run the diagnostics with the MML command UDU and change the TCSM state to WO-EX with the command USC.
8 Create circuit group.ZRCC:TYPE=CCS,NCGR=ATERTEST,CGR=1:DIR=IN,NET=NA0,SPC=200,LSI=AINA0;
9 Add circuit to CGR.ZRCA:CGR=1:ETPCM=1280,CRCT=1-1&&-31:CCSPCM=1;
ZRCA:CGR=1:ETPCM=1280,CRCT=2-1&&-31:CCSPCM=2;
ZRCA:CGR=1:ETPCM=1280,CRCT=3-1&&-31:CCSPCM=3;
ZRCA:CGR=1:ETPCM=1280,CRCT=4-1&&-27:CCSPCM=4;
10 Change the circuit states.ZCEC: ETPCM=1280,CRCT=1-1&&-31:BL;
ZCEC: ETPCM=1280,CRCT=1-1&&-31:WO;
ZCEC: ETPCM=1280,CRCT=2-1&&-31:BL;
ZCEC: ETPCM=1280,CRCT=2-1&&-31:WO;
ZCEC: ETPCM=1280,CRCT=3-1&&-31:BL;
ZCEC: ETPCM=1280,CRCT=3-1&&-31:WO;
ZCEC: ETPCM=1280,CRCT=4-1&&-27:BL;
ZCEC: ETPCM=1280,CRCT=4-1&&-27:WO;
Further informationFor detailed instructions on how to configure the remote BSC, see Configuring TCMS3i for combined BSC/TCSM installation
5.4.3 Creating the TCSM2The TCSM2 is a functional unit of the BSC. The BSC monitors the TCSM2 by using a LAPD link which is connected from the TCSM2's Transcoder Controller (TRCO) to the BSC's Operation and Maintenance Unit (OMU). The LAPD link is allocated to the 2 Mbit/s PCM frame (ETSI) or 1.5 Mbit/s T1 frame (ANSI) that carries the TCH/CCS7 between the MSC and the BSC. It is a 16 kbit/s link using the first two bits in time slot one (for ETSI, see figure Time slot allocation for full-rate traffic on Ater 2Mbit/s interface with the TCSM2 (ETSI) and for ANSI, figure A interface time slot allocation (ANSI)). In addition to monitoring, the LAPD link is also used for configuring, alarms, remote MMI sessions, and for software downloading to the TCSM2.
The TCSM2 software is kept in the BSC's hard disks and consists of three modules; software for the TRCO units, for the ET2E/A, ET2E-C, ET2E-S/SC, ET2E-T(B), ET2A-T(B), or ET2E-TC(B) units, and for the TR16 (ETSI) or TR12 (ANSI) units. These software modules are downloaded to the TCSM2 when necessary, that is when there is no software in the TCSM2 or it is different from that in the BSC.
72 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
One TCSM2 rack can contain up to eight transcoder units as shown in figures TCSM2 rack and cartridges (ETSI) and TCSM2 rack and cartridges (ANSI). Each transcoder unit consists of the transcoder cartridge and one ET cartridge having up to four ET2E/A, ET2E-C, ET2E-S/SC, ET2E-T(B), ET2A-T(B), or ET2E-TC(B) plug-in units.
Figure 16 TCSM2 rack and cartridges (ETSI)
TCSM2
0 1 2 3
TC1C
tracks: 0
TRCO
1
TR16
2
TR16
3
TR16
4
TR16
5
TR16
6
TR16
7
TR16
8
TR16
9
TR16
10
TR16
11
TR16
12
TR16
13
TR16
14
TR16
15
PSC1
ET1TC
tracks: 3210
tracks: 7654
ET2E
ET2E
ET2E
ET2E
ET2E
ET2E
ET2E
ET2E
(TCSM2 0) (TCSM2 2)
(TCSM2 1) (TCSM2 3)
(TCSM2 4) (TCSM2 6)
(TCSM2 5) (TCSM2 7)
POWER INPUT BLOCK
TC1C 0
TCSM2 0
TC1C 2
TCSM2 2
TC1C 1
TCSM2 1
TC1C 3
TCSM2 3
TC1C 4
TCSM2 4
TC1C 6
TCSM2 6
TC1C 5
TCSM2 5
TC1C 7
TCSM2 7
ET indexes and tracks: (higher part)ETs 0 and 1: track 0ETs 2 and 3: track 1ETs 4 and 5: track 2ETs 6 and 7: track 3
ET indexes and tracks: (lower part)ETs 0 and 1: track 4ETs 2 and 3: track 5ETs 4 and 5: track 6ETs 6 and 7: track 7
Coordinates of the cartridges:ET 0: nnc120-01 nn = rowET 1: nnc120-13 c = rackET 2: nnc120-49ET 3: nnc120-61TC1C 0: nnc088-01TC1C 1: nnc088-37TC1C 2: nnc058-01TC1C 3: nnc058-37TC1C 4: nnc030-01TC1C 5: nnc030-37TC1C 6: nnc002-01TC1C 7: nnc002-37
DN9812243 73
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
Figure 17 TCSM2 rack and cartridges (ANSI)
The TCSM2 rack, transcoder and ET cartridges along with the plug-in units are created to the BSC's equipment database. It is important to create the configuration and espe-cially the transcoder ETs correctly to the BSC since they are used to define the type and the number of the A interface PCMs (in ETSI) or T1s (in ANSI). This information is used by the transcoder when it configures its PCMs/T1s during restart.
The procedure consists of the following phases:
• Configuring the hardware for the TCSM2 (steps 1–8) • Connecting the TCSM2 functional units (steps 9–14) • Configuring the TCSM2 (steps 15–16)
In this procedure, parameter unit index refers to the number of the ET in the BSC.
Steps
1 Create the rack for TCSM2 (WTJ).ZWTJ:TC2E,<rack or cabinet coordinate>:PSFP=2,PSA=2;
Coordinates of the cartridges:
ET 0: nnc120-01 nn = rowET 1: nnc120-13 c = rackET 2: nnc120-49ET 3: nnc120-61TC1C 0: nnc088-01TC1C 1: nnc088-37TC1C 2: nnc058-01TC1C 3: nnc058-37TC1C 4: nnc030-01TC1C 5: nnc030-37TC1C 6: nnc002-01TC1C 7: nnc002-37
ET indexes and tracks: (lower part)
ETs 0 and 1: track 4ETs 2 and 3: track 5ETs 4 and 5: track 6ETs 6 and 7: track 7
ET indexes and tracks: (higher part)
ETs 0 and 1: track 0ETs 2 and 3: track 1ETs 4 and 5: track 2ETs 6 and 7: track 3
TCSM2
TCSM2 0
(TCSM2 0)
(TCSM2 1)
(TCSM2 2)
(TCSM2 3)
(TCSM2 4)
(TCSM2 5)
(TCSM2 6)
(TCSM2 7)
TCSM2 2
TCSM2 4
TCSM2 6 TCSM2 7
TC1C
tracks:
TRCO
TR12
TR12
TR12
TR12
TR12
TR12
TR12
TR12
TR12
TR12
TR12
TR12
TR12
TR12
PSC1
ET1TC
tracks: 3
ET2A
2
ET2A
1
ET2A
0
ET2A
tracks: 7
ET2A
6
ET2A
5
ET2A
4
ET2A
TCSM2 1
TCSM2 3
TCSM2 5
TC1C 0
0 1 2 3
TC1C 2
TC1C 4
TC1C 6 TC1C 7
TC1C 1
TC1C 3
TC1C 5
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
POWER INPUT BLOCK
Parameter Explanation
rack or cabinet coordinate Coordinate of the TCSM2.
74 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
2 Create a cartridge for the TC1C (WTC).ZWTC:TC1C,<cartridge coordinate>:P1=<coordinate>;
3 Create the TCSM unit (WTU).ZWTU:TCSM,<unit index>:<cartridge coordinate>;
4 Create transcoder controller plug-in unit, TRCO (WTP).ZWTP:TCSM,<unit index>:TRCO,0,0::GENERAL,2,<unit index>,TSL,1;
5 Create TR16/TR12 plug-in units (WTP).Two plug-in units are needed for each A interface PCM/T1:
ZWTP:TCSM,<unit index>:<piu type>,<piu index>,<track>;
6 Create the ET1TC cartridge (WTC).ZWTC:ET1TC,<cartridge coordinate>;
7 Create the unit ET1TC cartridge (WTU).ZWTU:TCSM,<unit index>:<coordinate of cartridge>;
Parameter Explanation
cartridge coordinate Coordinate of the transcoder unit. See figure TCSM2 rack and cartridges (ETSI) or TCSM2 rack and car-tridges (ANSI).
Parameter Explanation
cartridge coordinate Coordinate of the transcoder unit. See figure TCSM2 rack and cartridges (ETSI) or TCSM2 rack and car-tridges (ANSI).
Parameter Explanation
piu type ETSI: TR16, ANSI: TR12.
piu index Index of the TR16/TR12.
track Track of the TR16/TR12. For the right values, see figure TCSM2 rack and cartridges (ETSI) or TCSM2 rack and cartridges (ANSI).
Parameter Explanation
cartridge coordinate Coordinate of the ET1TC cartridge. See figure TCSM2 rack and cartridges (ETSI) or TCSM2 rack and car-tridges (ANSI).
DN9812243 75
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
8 Create ET2E/A, ET2E-C, ET2E-S/SC, ET2E-T, ET2A-T, or ET2E-TC plug-in units (WTP).ZWTP:TCSM,<unit index>,<unit coordinates>:<piu type>,<index>,<track>;
*RoHS compliant ET2A-TB, ET2E-TB and ET2E-TCB units are created to the equip-ment database as ET2A-T , ET2E-T and ET2E-TC.
9 Check that the A interface ETs and the connectable plug-in units of the TCSM2 are connected in the right order.They should be connected in the following order:
a) A interface ET. See Connecting the A interface ET.b) At least one ET of the TCSM2.c) TRCO of the TCSM2.
The ETs of the TCSM2 must be connected in ascending order starting from ET number one. The highway PCM is not connected.
g To delete the TCSM2, disconnect the units in reverse order.
10 Set the number of through connected channels (WGS).ZWGS:<highway pcm>:<number of through connected channels>;
11 Create transcoder PCMs (WGC).ZWGC:<highway pcm number>,<tc_pcm number>:POOL=<transcoder pcm pool numbers>:BCSU,<controlling unit index>;
Parameter Explanation
coordinate of cartridge Coordinate of the ET1TC cartridge. See figure TCSM2 rack and cartridges (ETSI) or TCSM2 rack and cartridges (ANSI).
Parameter Explanation
unit coordinates Coordinate of the ET1TC cartridge.
piu type ETSI: ET2E, ET2E-C, ET2E-S/SC, ET2E-T* or ET2E-TC*.
ANSI: ET2A or ET2A-T*.
piu index Index of the ET2E/A.
track Track of the ET2E/A. For the right values, see figure TCSM2 rack and cartridges (ETSI) or TCSM2 rack and cartridges (ANSI).
76 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
The table below shows which A-interface pools support which codecs and application software.
12 Connect the TRCO to the BSC (WUC).This command creates the LAPD link between the BSC and the TCSM2. A circuit group DTCSM and the circuit to it are created at the same time.
ZWUC:TCSM,<unit index>:TRCO,0;
13 Change the state of the TCSM2 to WO-EX (USC).This command automatically changes the state of the TCSM LAPD link to WO-EX. If the TCSM2 software does not exist or is different from that in the BSC, it is downloaded in this phase.
14 Check the state of the TCSM2 LAPD link (DTF).ZDTF:TCSM,<unit index>:OMU;
The transcoder has less PCM types than the BSC has pools. This results in the fact that when you are checking the PCM circuits from the transcoder end, the PCM types are different than the pools in the BSC. The following execution printouts illustrate this:
Example: Printout from the BSC (ETSI)ZWGO:36;EXECUTION STARTED
Parameter Explanation
pool type. ANSI: NU = not used.
Used in the first pool if the TCSM2A-C is in use.
controlling unit index Index of the BCSU controlling the speech circuits.
Supported codecs and software Supported A-interface pools Circuit type
FR, HR, EFR, AMR, 14.4D, HSCSD, AEC, TFO, NS, TTY
1 (FR)
2 (HR)
3 (DR)
5 (EFR & DR)
7 (EFR & DR)
20 (EFR & DR & D144)
23 (AMR)
G
10 (HS2)
21 (HS & D144)
H
13 (HS4)
22 (HS4 & D144)
I
Table 29 Possible combinations of circuit pools
DN9812243 77
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
ET_PCM 36 TC_PCM POOL TYPE ET_PCM_TSLSTCSM-36 TCSM2 1 21 EFR&DR&HS2&D144 1 && 16 2 23 AMR 17 && 24 3 2 HR 25 && 28 4 22 EFR&DR&HS4&D144 29 && 30 THROUGH CONNECTIONS NR64 = 1 36 - 31 <--> 1 - 16
COMMAND EXECUTED
Example: Printout from the transcoder (ETSI)ZDDX:TCSM,36:"ZRD";
TCSM_036:LUC> ZRD
/* TRANSCODER PCM TYPES */
GROUP SWITCH GSWB
PCM TYPE
PCM-1 EFR & FR & HR & HS2 & D144PCM-2 AMRPCM-3 HRPCM-4 EFR & FR & HR & HS4 & D144PCM-5 NUPCM-6 NUPCM-7 NU
/* COMMAND EXECUTED */
Example: Printout from the BSC (ANSI)ZWGO:32&&35;
EXECUTION STARTED
ET_PCM 32 TC_PCM POOL TYPE ET_PCM_TSLSTCSM-32 TCSM2 1 - NU - 2 23 AMR 1 && 6 3 5 EFR&FR 7 && 12 4 21 EFR&FR&HS2&D144 13 && 22 THROUGH CONNECTIONS NR64 = 2 32 - 24 <--> 2 - 24
ET_PCM 33 TC_PCM POOL TYPE ET_PCM_TSLSTCSM-33 TCSM2 1 - NU - 2 13 EFR&FR&HS4 2 && 20 THROUGH CONNECTIONS NR64 = 4 33 - 24 <--> 2 - 16
ET_PCM 34 TC_PCM POOL TYPE ET_PCM_TSLS
78 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
TCSM-34 TCSM2 1 5 EFR&FR 1 && 6 2 10 EFR&FR&HS2 7 && 18 3 13 EFR&FR&HS4 19 && 23 THROUGH CONNECTIONS NR64 = 1 -
ET_PCM 35 THROUGH CONNECTIONSTCSM-35 TCSM2 -
COMMAND EXECUTED
Example: Printout from the transcoder (ANSI-C)ZDDX:TCSM,32:"ZRD";
TCSM_032:LUC> ZRD
/* TRANSCODER PCM TYPES */
GROUP SWITCH GSWB
PCM TYPE
PCM-1 NUPCM-2 AMRPCM-3 FR & EFR & D144PCM-4 EFR & FR & HR & HS2 & D144PCM-5 NUPCM-6 NUPCM-7 NU
/* COMMAND EXECUTED */
15 Add through connected channels (WGA).ZWGA:<highway pcm circuit>:<tc_pcm circuit>;
16 Output and check the through connected channels (WGO).ZWGO:<highway pcm number>:<output mode>;
Further informationNext, create the MTP.
Limitations in Multimedia Gateway (MGW) line card IW1S1 capacityWhen using TDM over STM-1 (IW1S1/IW1S1-A units) for user plane traffic, the capacity may be limited. The total IW1S1 capacity in U3B & U3C is 1602 timeslots.
For more information on this limitation, see the section IW1S1 and IW1S1-A with MX622 capacity limitation for user plane traffic in Routing and Digit Analysis in MGW in the Mul-timedia Gateway Product Documentation.
DN9812243 79
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
Degradation of TCSM3i capacity can be totally avoided if SDH multiplexer is used between TCSM3i and MGW.
The maximum capacity of TCSM3i in combined installation can not be fully used due to the limitation of MGW line card. A maximum of 7896 channels of the TCSM3i capacity can be used in ETSI environment. An alternative to overcome the ill effects of this limi-tation is to leave four TR3E plug-in units in every TC2C cartridge unequipped in the TCSM3i for combined BSC/TCSM. This results in the MGW supporting the TCSM3i with a maximum of 7680 channels in an ETSI installation.
5.5 Creating Ater Connection to Multimedia GatewayMultimedia Gateway (MGW) implements the same base transcoding functionality and features as TCSM. However, MGW does not support the same pool set as the BSC. Fur-thermore, MGW and TCSM3i do not support 8kbit/s submultiplexing on Ater interface, but TCSM2 does.
There is no O&M LAPD link between BSC and MGW so BSC does not control MGW at all. This means that the user is responsible for creating identical transcoder configura-tions to both BSC and MGW. Since there is no LAPD link, there is no need to equip TCSM functional unit into the BSC HW database.
Capacity TR3E TC2C
TR3E 1 120 120
TR3E 2 120 240
TR3E 3 120 360
TR3E 4 80 440
TR3E 5 0 440
TR3E 6 89 529
TR3E 7 120 649
TR3E 8 120 769
TR3E 9 93 862
TR3E 10 0 862
TR3E 11 58 920
TR3E 12 120 1040
TR3E 13 120 1160
TR3E 14 120 1280
TR3E 15 0 1280
TR3E 16 0 1280
TCSM3i Capacity 7680
Table 30 TCSM3i capacity with four TR3E unequipped
80 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
Figure 18 Ater interface with MGW
Steps
1 Set the number of through connected channels (WGS).ZWGS:<highway pcm>:<number of through connected channels>;
2 Create transcoder PCMs (WGC).ZWGC: <highway pcm number>,<tc_pcm number>:POOL=<transcoder pcm pool numbers>:BCSU, <controlling unit index>;
RAN CN
BSC Nokia or otherMSC
MGW
2G TC
BSC NSS
Ater
A
8k/16k/32k/64k
64k/56k
16k/32k/64k
Ater
TCSM
Pool number
Supported codecs SubChannel
1 FR (Full Rate) 16 kbit/s
3 DR* 16 kbit/s
5 EFR (Enhanced Full Rate) & FR 16 kbit/s
7 EFR & DR* 16 kbit/s
10 HS2 (HSCSD max 2 x FR data) & EFR & DR* 32 kbit/s
13 HS4 (HSCSD max 4 x FR data) & EFR & DR* 64 kbit/s
Table 31 Circuit pools and supported codecs (with SubChannel bit information) when using MGW
DN9812243 81
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
g *DR means Dual Rate, that is, both GSM-FR (FR) and GSM-HR (HR, Half Rate) codecs are defined to be supported by the pool. However, in MGW, HR is an optional feature and is supported only if the user has purchased a separate HR licence; whereas FR is always supported.
For more information, see Multimedia Gateway (MGW) Functional Description in Multi-media Gateway Product Documentation.
Example: Printout of transcoder configurationsZWGO:100:;
EXECUTION STARTED
ET_PCM 100 TC_PCM POOL TYPE ET_PCM_TSLS 1 5 EFR&FR 1 && 8 2 5 EFR&FR 9 && 16 THROUGH CONNECTIONS -
COMMAND EXECUTED
Example: Setting the number of through connectionsZWGS:100:2:;
EXECUTION STARTED
/*** TCSM NOT EQUIPPED - THIS CONFIGURATION IS POSSIBLE ONLY WHEN TRANSCODING IS PROVIDED BY SOME OTHER DEVICE ***/
CONFIRM COMMAND EXECUTION: Y/N ?
Example: Creating a TC_PCMZWGC:100,:POOL=5:BCSU,5:;
EXECUTION STARTED
20 EFR & DR & D144 (14.4 kbit/s data speed)* 16 kbit/s
21 HS2 & EFR & DR & D144* 32 kbit/s
22 HS4 & EFR & DR & D144* 64 kbit/s
23 AMR (HR AMR & FR AMR) 16 kbit/s
28 EFR & DR & AMR & D144* 16 kbit/s
32 EFR & DR & AMR & HS4 & D144* 64 kbit/s
37 AMR & FR AMR-WB 16 kbit/s
Pool number
Supported codecs SubChannel
Table 31 Circuit pools and supported codecs (with SubChannel bit information) when using MGW (Cont.)
82 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
/*** TCSM NOT EQUIPPED - THIS CONFIGURATION IS POSSIBLE ONLY WHEN TRANSCODING IS PROVIDED BY SOME OTHER DEVICE ***/
CONFIRM COMMAND EXECUTION: Y/N ? Y
ET_PCM 100 TC_PCM POOL TYPE ET_PCM_TSLS 1 5 EFR&FR 1 && 8
UPDATING FILES TO DISK. WAIT 4 SECONDS.
COMMAND EXECUTED
5.6 Creating the MTPSteps
1 Create signalling links (NCC).It is strongly recommended to have at least two signalling links in the A interface. Fur-thermore, the links should not be controlled by the same Base Station Controller Unit (BCSU).
ZNCC:<signalling link number>:<external PCM-TSL>,<link bit rate>:BCSU,<unit number>:<parameter set number>;
2 Create the local signalling point code (NRP).ZNRP:<signalling network>,<bsc signalling point code>,<bsc signalling point name>,SEP:STAND=<ss7 standard>:<number of spc subfields>;
Parameter Explanation
parameter set number ETSI: value 0 is recommended.
ANSI SS7: value 2 must be used.
Parameter Explanation
ss7 standard ETSI: ITU-T is usually used.
ANSI: ANSI is recommended.
number of spc subfields ETSI: value 1 is usually used.
ANSI: value 3 is usually used.
DN9812243 83
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
3 Create the signalling link set (NSC).To implement this step, choose one of the following alternatives:
a Create the signalling link set for the control plane directly to the MSS.ZNSC:<signalling network>,<msc signalling point code>,<msc signalling link set name>:<signalling link number>,<signalling link code>;
The signalling link code of the signalling link must be the same as the code of the corresponding link in the MSC.
You can add up to four signalling links to the signalling link set. Repeat the last three parameters for each signalling link.
b Create the signalling link set for the Ater interface transparently via the MGW to the MSC Server.ZNSC:<signalling network>,<mgw signalling point code>,<mgw signalling link set name>:<signalling link number>,<signalling link code>;
The parameters signalling network and signalling point code define the network element where the signalling link set leads to.
4 Add links to the signalling link set (NSA).This step is needed only if all the links were not added to the link set in the previous step.
ZNSA:<signalling network>,<msc or mgw signalling point code>,<msc or mgw signalling link set name>:<signalling link number>,<signalling link code>;
5 Create the signalling route set (NRC).To implement this step, choose one of the following alternatives:
a Create the signalling route set for the control plane directly to the MSS.ZNRC:<signalling network>,<msc signalling point code>,<msc signalling point name>,<parameter set number>,<load sharing status>,<restriction status>:,,,0;
b Create the signalling route set for the Ater interface transparently via the MGW to the MSC Server.Direct connections:
ZNRC:<signalling network>,<mgw signalling point code>,<mgw signalling point name>,<parameter set number>,<load sharing status>,<restriction status>:,,,0;
Parameter Explanation
parameter set number Value 1 is recommended.
load sharing status D is recommended.
restriction status R is recommended.
84 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
STP configurations:
ZNRC:<signalling network>,<mss signalling point code>,<mss signalling point name>,<parameter set number>,<load sharing status>,<restriction status>:<mgw signalling transfer point code>,<mgw signalling transfer point name>,0;
6 Allow activation of the signalling links (NLA).ZNLA:<signalling link numbers>;
7 Allow activation of the signalling route (NVA).To implement this step, choose one of the following alternatives:
a Allow activation of the signalling route for the control plane directly to the MSS.ZNVA:<signalling network>,<msc or mss and mgw signalling point code>:;
b Allow activation of the signalling route for the Ater interface transparently via the MGW to the MSC Server.ZNVA:<signalling network>,<msc or mss signalling point code>:<signalling network>,<mgw signalling point code>;
8 Change signalling link states (NLC).ZNLC:<signalling link numbers>,ACT:;
9 Change route set state (NVC).To implement this step, choose one of the following alternatives:
a Change route set state for the control plane directly to the MSS.ZNVC:<signalling network>,<msc or mss and mgw signalling point code>::ACT;
b Change route set state for the Ater interface transparently via the MGW to the MSC Server.ZNVC:<signalling network>,<msc or mss signalling point code>:<signalling network>,<mgw signalling point code>:ACT;
Further informationNext, create the SCCP.
Parameter Explanation
parameter set number Value 0 is recommended in STP configurations, value 1 for direct connections
load sharing status D is recommended.
restriction status N is recommended in STP configurations, R for direct con-nections.
DN9812243 85
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
5.7 Creating the SCCPThe parameter values shown in the table apply in each step in this procedure.
Steps
1 Create service (NPC).ZNPC:<signalling_network>,03,SCCP:Y:Y,208,10F;
2 Define SCCP for the BSC's own signalling point (NFD).ZNFD:<signalling network>,<bsc signalling point code>,<signalling point parameter set number>:<subsystem number>,<subsysten name>,<subsystem parameter set number>,;
3 Define SCCP for the MSC's or MSS's signalling point (NFD).ZNFD:<signalling network>,<msc or mss signalling point code>,<signalling point parameter set number>:<subsystem number>,<subsystem name>,<subsystem parameter set number>;
See the previous step for recommended parameter values.
4 Modify broadcast status of SCCP signalling points (OBM).ZOBM:<signalling network>,<bsc signalling point code>,<subsystem name>::Y;
Parameter Explanation
subsystem number ETSI: FE, ANSI: DE.
subsystem name ETSI: BSSAP, ANSI: RSAP.
Parameter Explanation
signalling point parameter set number ETSI: value 1 is recommended.
ANSI: no recommended value.
subsystem number ETSI: FE, ANSI: DE.
subsystem name ETSI: BSSAP, ANSI: RSAP.
subsystem parameter set number ETSI: value 1 is recommended.
ANSI: no recommended value.
Parameter Explanation
subsystem number ETSI: FE, ANSI: DE.
subsystem name ETSI: BSSAP, ANSI: RSAP.
86 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
5 Modify the local broadcast status of SCCP subsystems (OBC).ZOBC:<signalling network>,<msc or mss signalling point code>,<subsystem name>::Y;
6 Change the SCCP state at BSC side (NGC).ZNGC:<signalling network>,<bsc signalling point code>:ACT;
7 Change the SCCP state at MSC side (NGC).ZNGC:<signalling network>,<msc or mss signalling point code>:ACT;
8 Change subsystem state at BSC side (NHC).ZNHC:<signalling network>,<bsc signalling point code>:<subsystem>:ACT;
The value of the parameter subsystem is BSSAP in ETSI and RSAP in ANSI.
9 Change subsystem state at MSC or MSS side (NHC).ZNHC:<signalling network>,<msc or mss signalling point code>:<subsystem>:ACT;
The value of the parameter subsystem is BSSAP in ETSI and RSAP in ANSI.
Further informationSegmentation has to be used when Inter-System Handover (ISHO) is active.
Parameter 14 XUDT_USED determines whether the connectionless SCCP uses the segmentation. The recommended value is YES.
Parameter 15 UDT_DENIED determines whether unit data (UDT) is sent as a single extended unit data (XUDT) message. The recommended value is NO.
Parameter 26 LUDT_USED determines whether all messages are sent as long unit data (LUDT) messages without segmentation. The recommended value is NO.
Parameter 27 CO_SEGM_USED determines whether the connection oriented SCCP uses the segmentation. The recommended value is YES.
You can modify the values of SCCP signalling point parameter set with command ZOCM.
For more instructions, see section Optimising SCCP configuration in Common Channel Signalling (MTP, SCCP and TC).
Next, Creating the speech channels.
Parameter Explanation
subsystem number ETSI: FE, ANSI: DE.
subsystem name ETSI: BSSAP, ANSI: RSAP.
DN9812243 87
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
5.8 Creating the speech channelsSpeech circuits are used to carry the actual user data through the A interface. One circuit is needed for each ongoing call. With conventional hunting the circuit is chosen by the MSC which means the MSC has to know the circuits of the BSC and their status. That is why the circuits must be identified by both the MSC and the BSC. This is accom-plished by using CICcodes. A CIC code consists of the CCSPCM and the time slot of the circuit. The CIC codes must be the same at both ends.
Reversed Hunting can be activated here. The following instructions apply when activat-ing it in a new BSC. If you want to change the BSC to use Reversed Hunting instead of normal hunting, see Activating and Testing BSS10005: Reversed Hunting.
For more information on Reversed Hunting, see Circuit configuration on the A interface in Half Rate, and A interface circuit allocation in Radio Channel Allocation.
Note that Multipoint A Interface cannot be used if Reversed Hunting is activated.
Figure 19 Multiplexed and non-multiplexed A interface with 8 kbit GSWB
Steps
1 Create a circuit group (RCC).ZRCC:TYPE=CCS,NCGR=<ciruit group name>,CGR=<circuit group number>:DIR=<direction>,NET=<signalling network>,SPC=<msc signalling point code>,LSI=<line signalling>;
Note that the circuit group name must have the same name as the one created for MSC. In addition the circuit group SPC must be the same peer entity (e.g. MSC/MSS) with which the BSC is carrying 3GPP 48.008 BSSAP signalling.
BSCGSWB
MultiplexedA interface
Speech circuits
Non-multiplexedA interface
ET 32
ET 34
ETPCM 32
ETPCM 34
Parameter Explanation
direction To activate Reversed Hunting: OUT.
If you do not want to activate Reversed Hunting: IN.
line signalling DUMMY, AINA0, AINA1, AIIN0, AIIN1, DSS01.
88 DN9812243
BSS Integration
Id:0900d805807d47d0Confidential
Creating the A interface
2 Add circuits to the circuit group (RCA).If more speech circuits are needed they must be added to the previously created circuit group.
• ETSI:In multiplexed cases:ZRCA:NCGR=<circuit group name>:ETPCM=<etpcm>,CRCT=<circuit(s)>,CRCTSTEP=1:CCSPCM=<number of PCM system>:;In non-multiplexed cases:ZRCA:CGR=1:ETPCM=<etpcm>,CRCT=<circuits>:CCSPCM=<number of PCM system>:;Note that one to six (ETSI) or one to seven (ANSI) transcoder PCMs can be used towards the MSC if the BSC is equipped with the GSWB. The amount of PCMs and TSLs depends on channel types: 8 Kbit/s (HR), 16 Kbit/s, 32 Kbit/s (HS2), 64 Kbit/s (HS4, through connected signalling channels). The same transcoder unit can have PCMs of different types, and the channels can be of a multimode type.For more information, see the figures Time slot allocation for full-rate traffic on Ater 2Mbit/s interface with the TCSM2 (ETSI) and A interface time slot allocation (ANSI).
• ANSI:ZRCA:NCGR=<circuit group name>,ETPCM=<etpcm>,CRCT=<circuit(s)>,CIC=<circuit identification code>,CICDIR=<direction of CIC>;
3 Activate Reversed Hunting (optional).If you do not want to activate Reversed Hunting, go to step 4.
Steps
a Create route (RRC).ZRRC:EXT:ROU=<route number>,OUTR=AINTF,STP=1,NCGR=<circuit group name>;
g Route is created only if Reversed Hunting is used.
The route number must be the same as the circuit group number.
b Activate circuit group (CRM).ZCRM:NCGR=<circuit group name>:WO;
c Create circuit group for null PCM and add circuits (RCC, RCA).ZRCC:TYPE=SPE,NCGR=<circuit group name>,CGR=<circuit group number>:FORMAT=0,HUNTED=N;
ZRCA:NCGR=<circuit group name>,CRCT=0–0&-1;
d Activate Reversed Hunting (WOA).ZWOA:2,643,A;
DN9812243 89
BSS Integration Creating the A interface
Id:0900d805807d47d0Confidential
4 Change the state of the speech circuits (CEC).Immediately after creation the circuits are in NU-US state. The state must be changed to WO-EX before the circuits can be used.
ZCEC:ETPCM=<etpcm>,CRCT=<circuit>:<state>;
ZCEC:ETPCM=<circuit>,CRCT=<circuit>:WO;
Parameter Explanation
state If Reversed Hunting is used: BA.
If Reversed Hunting is not used: BL.
90 DN9812243
BSS Integration
Id:0900d805807f6fecConfidential
Synchronising the A interface
6 Synchronising the A interfaceFor an overview, see Overview of BSS integration.
Before you startThe A and Ater interface transport has been connected into operation between the core Network and the BSC. In the BSC the user has to select the ETs that will be used as synchronisation inputs and install the synchronisation cables between the selected ETs and the clock unit.
Normally three ETs are used for synchronisation. The synchronisation input with the highest priority (2M1) should be in the state CONNECTED and in use (USED INPUT). The other inputs (2M2 and 2M3) should be in the state CONNECTED.
Steps
1 Check the state of the synchronisation (DRI).ZDRI;
Expected outcomeNormally, it gives the following output:
CL1TG:
INPUT STATE USED INPUT PRIORITY----- --------------- ---------- ----------2M1 CONNECTED 2M1 72M2 CONNECTED - 62M3 CONNECTED - 5SYNCHRONISATION UNIT WORKING MODE ......... HIERARCHIC SYNCHRONISATIONFUNCTION AUTOMATIC RETURN FROM PLESIOCHRONOUS OPERATION .......... ONSYNCHRONISATION UNIT 0 OSCILLATOR CONTROL WORD VALUE ....... 31896FUNCTION AUTOMATIC USE OF REPAIRED INPUTS ........................ ONSYNCHRONISATION UNIT 1 OSCILLATOR CONTROL WORD VALUE ....... 31635SYNCHRONISATION UNIT 0 OSCILLATOR CONTROL MODE ............. NORMALSYNCHRONISATION UNIT 1 OSCILLATOR CONTROL MODE ............. NORMALTIMER: SYNCHRONISATION SIGNAL MALFUNCTION TOLERANCE TIME ... 5 MINTIMER: REPAIRED SYNCHRONISATION INPUT OBSERVATION TIME ..... 10 MINCOMMAND EXECUTED
2 Create or delete synchronisation inputs if necessary (DRC, DRD).ZDRC:<synchronization input>;
ZDRD:<synchronization input>;
The number of possible synchronisation inputs depends on how many transport lines are connected between the core network and the BSC. The maximum number of A/Ater lines that can be used as synchronisation lines is 3 if CL1TG is used.
Parameter Explanation
synchronization input 2M1, 2M2, 2M3
DN9812243 91
BSS Integration Synchronising the A interface
Id:0900d805807f6fecConfidential
3 Change the supervision timers for the inputs if necessary (DRS).Use the DRS command.
4 Check if there are any faults.The following steps include typical faults and instructions on how to correct them.
Steps
a To implement this step, choose one of the following alternatives:
1 If The synchronisation units are not in synchronous operation mode.
Then
Force the synchronisation units to use a specific input (DRS).ZDRS::U=<2M1 - 2M4>;
2 If The CL1TG will search the entire control range in order to lock the units to a certain input.
Then
Wait for the alarm to be cancelled (which may take a couple of minutes) and remove the forced use of input (DRS).ZDRS::U=OFF;
3 If Operation mode is not hierarchical.
Then
Check that the operation mode has been set to hierarchical (DRM).ZDRM:H;
4 If The settings of the ETs are not correct.
Then
Check the settings of the ETs.The TCL signal should be 8 kHz. In ET1E it is selected by strapping, but in other ET variants it is 8kHz permanently.
5 If The control words of both CL1TGs approach the values 0 to 65534.
Then
Check the connection.It is possible that the incoming circuit is connected to a loop.
5 Change the synchronisation inputs.
Steps
a Disconnect the incoming signal from the first input.
Expected outcomeThis will cause normal circuit alarms. After a time delay of more than the timer: SYN-CHRONISATION SIGNAL MALFUNCTION TOLERANCE TIME allows, both syn-
92 DN9812243
BSS Integration
Id:0900d805807f6fecConfidential
Synchronising the A interface
chronisation units will change to the second input. This can be seen in the LEDs of the CL1TG plug-in units and on the alarm printer:
2641 FAILURE IN SYNCHRONISATION SIGNAL
0630 SYNCHRONISATION SIGNAL CHANGED
b Disconnect the incoming signal from the second output.
Expected outcomeThe results should be similar to the earlier ones.
6 Go to plesiochronous mode of operation.Disconnect the incoming signal from the third input (the last synchronisation input has been disconnected) in CL1TG.
Expected outcomeThe synchronisation units will go to PLESIOCHRONOUS OPERATION mode. All syn-chronisation input indicators in the active CL1TG unit will extinguish, only the current indicator light is on. All 3/4 input indicators in the passive CL1TG unit are lit, but not the current indicator light. The alarm printer will print out the following:
2641 FAILURE IN SYNCHRONISATION SIGNAL
2631 OPERATION MODE CHANGED TO PLESIOCHRONOUS
7 Return to synchronous mode of operation.Return the circuits to their normal state one by one starting from the circuit with the lowest priority.
Expected outcomeThe synchronisation units will synchronise themselves to the input 2M3/2M4 after a time delay of more than the timer REPAIRED SYNCHRONISATION INPUT OBSERVATION TIME. On the alarm printer the following alarms will be cancelled:
2641 FAILURE IN SYNCHRONISATION SIGNAL
2631 OPERATION MODE CHANGED TO PLESIOCHRONOUS
8 Check possible slips in the synchronous mode of operation (YMO).ZYMO:ET,<index>:SLI;
The observation begins daily at 00.00 and should normally show no slips.
9 Check oscillator adjustments.The CL1TG has no adjustments in the synchronous mode of operation.
DN9812243 93
BSS Integration Adding DN2, SSS, DMR and BBM to the service chan-nel
Id:0900d805805cedebConfidential
7 Adding DN2, SSS, DMR and BBM to the service channelThe connection between the BSC and the managed equipment is established either through a BSC-BTS O & M link or a Q1 service channel. The possible equipment types at a Base Transceiver Station (BTS) site include Base Station Interface Equipment (BIE), Transmission Unit (TRU), Digital Microwave Radio Link (DMR), and other trans-mission equipment (TRE).
All equipment with the same alarm unit type must have a unique index in the BSC con-cerned. All equipment in the same channel must have a unique address.
DN2 The Q1 service channel comes in TSL31 bits 7-8 to the 2M port of the DN2 interface unit (IU2). The Q1 service channel is forwarded through an extra loop connection to the Control Unit (CU); either one port of the IU2 is connected to the 2M interface of the CU or two IU2 ports are con-nected together with a local cable. The supported baud rates of the service channel are 1200, 2400 and 4800.
SSS The Supervisory Substation is located in the same rack with other trans-mission equipment, normally with the DN2. The Q1 service channel is forwarded to the SSS with a local cable.
DMR The Digital Microwave Radio link cannot pick the Q1 service channel from a time slot. The Q1 service channel is forwarded to the DMR with a local cable from another source, normally DN2. The supported baud rates of the service channel are 1200, 2400, 4800, and 9600.
BBM The Baseband Modem cannot pick the Q1 service channel from a time slot. The Q1 service channel is forwarded to the BBM through an Inte-grated Line Terminal (ILT) plug-in unit from the DN2.
TRE Other types of transmission equipment, for example optical line equip-ment, are handled in the BSC with the common name Transmission Equipment (TRE).
Figure 20 Transmission equipment at Q1 service channel
For an overview, see Overview of BSS integration.
MMI SYSTEM
MML
DN2
ILT
SSS
DMR
TRE
BBM
TRE Q1ch
Q1ch
NetActLocalQ1bus
X.25/
LAN
94 DN9812243
BSS Integration
Id:0900d805805cedebConfidential
Adding DN2, SSS, DMR and BBM to the service chan-nel
Steps
1 Create the service channel (QWC).ZQWC:<service channel number>, [S | P def]:<baud rate>,<bandwidth>,<used bits>:<external PCM-TSL>,<sub tsl>;
If you want to utilise Q1 bus protection in BSC, you must create secondary channels for all the primary Q1 channels that are to be protected.
2 Add equipment to the service channel (QWA).ZQWA:CH=<service channel number>:DN2=<DN2 index>:<alarm unit address 1>;
ZQWA:CH=<service channel number>:BBM=<BBM index>:<alarm unit address 2>;
ZQWA:CH=<service channel number>:DMR=<DMR index>:<alarm unit address 3>;
ZQWA:CH=<service channel number>:SSS=<SSS index>:<alarm unit address 4>;
ZQWA:CH=<service channel number>:TRE=<TRE index>:<alarm unit address 5>;
Addresses have to be set locally to the equipment with a hand-held service terminal.
3 Change the state of the service channel (QWS).ZQWS:<service channel number>:AL;
DN9812243 95
BSS Integration Creating the Abis interface
Id:0900d805805cedeeConfidential
8 Creating the Abis interfaceFor an overview, see Overview of BSS integration.
In this phase, the ET is connected to the Abis interface to connect the base stations to the BSC (see the figure below).
Figure 21 Abis interface
Steps
1 Check that the ET is connected (WUP).The ET must be connected before it can be used. For how to check if the ET is already connected, see Connecting the A interface ET.
Check that the ET is connected with the WUP command.
2 To implement this step, choose one of the following alternatives:
a If ET is already connected
Then
Check that the ET is in WO state and restart the ET (USU).The state of the ET can be changed with command USC.
The ET must be restarted to ensure that the correct ET software is loaded into the unit.
ZUSU:ET,<pcm_index>,C=TOT;
b If ET is not connected
Then
Connect the ET (WUC).ZWUC:ET,<ET index>:<plug-in unit type>,0:IF=ABIS:BCSU,<BSCU index>;
BTSBSC
ET TRU
Abis interface
OMU
TRX 1
TRX 2
TRX 3
OMUSIG
TRXSIG1 + 8 TCHs
TRXSIG2 + 8 TCHs
TRXSIG3 + 8 TCHs
96 DN9812243
BSS Integration
Id:0900d805805cedeeConfidential
Creating the Abis interface
*RoHS compliant ET2A-TB, ET2E-TB and ET2E-TCB units are created to the equip-ment database as ET2A-T , ET2E-T and ET2E-TC.
Steps
a Change the state of the BCSU to WO-EX.
b Change the state of the ET to WO-EX.
3 Check and change the frame alignment mode (ETSI)/T1 functional mode (ANSI) for ET if needed.For more information about configuring the frame alignment mode/T1 functional mode, see Connecting the A interface ET.
Parameter Explanation
plug-in unit type Type of the ET:
ETSI: ET1E, ET1E-C, ET2E, ET2E-C, ET2E-S, ET2E-SC, ET2E-T*, ET2E-TC*, ET4E, ET4E-C, ET16, ETS2 or ETIP1_A
ANSI: ET2A, ET2A-T*, ET4A, ET16, ETS2 or ETIP1_A.
DN9812243 97
BSS Integration Initialising base stations
Id:0900d805807d4158Confidential
9 Initialising base stationsEach base station has one LAPD link called OMUSIG (see figure Abis interface). It is connected to the Operation and Maintenance Unit (OMU) of the base station and used for O&M purposes like remote sessions to the BTS, software up- and downloading, transferring of alarms, and transferring of configuration information.
Each TRX has one LAPD link called TRXSIG and up to eight traffic channels. There can be fewer traffic channels if some of the TRXs' radio interface time slots are used for sig-nalling. The bit rate of the LAPD links can be either 16 or 64 kbit/s. Also 32 kbit/s is possible for TRX links.
In this phase, the LAPD links are created and the base stations are created to the BSC's radio network database. In terms of BSC, a base station consists of BCF, BTSs, TRXs, and handover and power control parameters.
The hardware database is attached only to Talk-family base stations. In the other types, the TEI of the TRX links is the same as the TRX number in the BSC. The TEI of the OMU links is always 1.
In the case of Flexi EDGE base stations, the TRXSIG links and traffic channels data created in the BSC can be downloaded and used by the Flexi EDGE base station auto-matically. For more information, see Flexi EDGE BTS Commissioning in the Flexi EDGE Base Station Product Documentation.
The following instructions apply to Talk-family, UltraSite EDGE, MetroSite, Flexi EDGE, Flexi Multiradio and BTSplus base stations.
For an overview, see Overview of BSS integration.
9.1 Creating LAPD links and a base station, and initialising the base station parametersA LAPD link can be created either to a certain physical Base Station Controller Signal-ling Unit (BCSU) or to a logical BCSU address. When the link is created to a logical BCSU address the actual controlling unit may not necessarily be the one given in the command. The concept of logical BCSU address was introduced to eliminate the effect of BCSU switchovers to radio network planning. In terms of MMI commands, only the command name is different with logical BCSU addresses.
It depends on the type of the BTS which links must be created. For more information, see Creating D channels on Abis interface.
Steps
1 Create LAPD links (DSE).Create 16, 32 or 64 kbit LAPD links. Create the links for O&M signalling link (OMUSIG) and TRX signalling links (TRXSIG). If you are creating a 64kbit link, do not give <SUB-TSL>.
ZDSE:<D-channel link set name>:BCSU,<unit index>:<service access point identifier>,<terminal endpoint identifier>:<bitrate>,<PCM-TSL>,<SUB-TSL>;
98 DN9812243
BSS Integration
Id:0900d805807d4158Confidential
Initialising base stations
If logical BCSUs are used, use the DSL command with the same parameters.
2 Create a base control function (EFC).The base control function (BCF) is a logical counterpart of the actual base station. It is connected to the OMUSIG link created earlier.
As a default, the operational state of the new BCF is 'Locked' (L). It is recommended that you first create the entire BCF site (BCF, BTS, and the TRXs) and unlock the TRXs and BTSs of the BCF, before you change the state of the BCF to 'Unlocked'.
In the case of Flexi EDGE Base Station, the administrative state of BCF is also 'Locked' after creation, but it is created as 'Automatic Unlock Allowed' by default. It means that when the BTS site has been commissioned and it indicates the start up for the BSC, the BSC automatically changes the administrative state of the BCF to 'Unlocked'.
• All site types if it is being autoconfigured:ZEFC:<bcf identification>,<site type>:DNAME=<D-channel link set name>;
Further informationThe BCF parameters can be modified later with the EFM and EFT commands if needed.
3 Create a base transceiver station (EQC).A base transceiver station (BTS) is a logical counterpart of a sector in a base station site. It should not be confused with a base station even though they have the same abbrevi-ation.
ZEQC:BCF=<BCF identification>,BTS=<BTS identification>,NAME=<BTS name>,:CI=<cell identity>,BAND=<frequency band in use>:NCC=<network colour code>,BCC=<BTS colour code>:MCC=<mobile country code>,MNC=<mobile network code>,LAC=<location area code>:;
Further informationThe BTS parameters can be modified later with the EQE, EQF, EQG, EQH, EQJ, EQK, and EQM commands.
4 Create a transceiver (ERC).A transceiver (TRX) is a logical counterpart of the transmitter-receiver equipment in the base station. It is connected to the TRXSIG link created earlier.
• All site types if it is being autoconfigured:ZERC:BTS=<BTS identification>,TRX=<transceiver identification>::FREQ=<frequency>,TCS=<training sequence
Parameter Explanation
service access point identifier 62 for OMUSIG, 0 for TRXSIG.
terminal endpoint identifier Must the same as defined in the BTS. Usually the same as the TRX number. For OMU link, the value is 1.
DN9812243 99
BSS Integration Initialising base stations
Id:0900d805807d4158Confidential
code>,PCMTSL=<Abis speech circuit>:DNAME=<D-channel telecom link set name>:CH0=<RTSL type 0>,SIGN=<subslots for signalling>;
Further informationThe TRX parameters can be modified later with the ERM command.
5 Create default power control parameters of the BTS (EUC).Each cell must have a power control parameter set.
ZEUC:BTS=<BTS identification>;
Further informationYou can modify the power control parameters with the EUG, EUA, EUQ, and EUS com-mands.
6 Create default handover control parameters (EHC).Each cell must have a handover parameter set.
ZEHC:BTS=<BTS identification>;
You can modify the handover control parameters with the EHG, EHA, EHS, EHQ, EHI, EHD, EHN, EHX, EHY, EHP commands.
7 Create neighbouring cell information (EAC).Define the list of cells where mobiles can make a handover when using the cell.
Create the adjacent cells.
• Adjacent cell located in the same BSC:ZEAC:BTS=<BTS identification>:ABTS=<adjacent cell identification>;
• Adjacent cell located in a different BSC:ZEAC:BTS=<BTS identification>:LAC=<location area code>,CI=<cell identification>:NCC=<network colour code>,BCC=<BTS colour code>,FREQ=<BCCH frequency>,:
The adjacent cell parameters can be modified with the EAM command.
8 Check and change the synchronisation of TalkFamily, UltraSite, Flexi EDGE, and MetroSite BTSs if necessary (EFM).Check that the synchronisation is suitable. The default is the internal clock of the BTS.
Change the synchronisation of the BCF to external synchronisation if necessary.
If the synchronisation settings are not defined or synchronisation is not enabled for the BCF(s) in the BSC Radio Network database, then the BTS site's own synchronisation settings are valid.
There are three alternative ways to define synchronisation for the BTS (and LMU) via BSC: the internal clock of the BTS, BSS synchronisation, and Site synchronisation.
For further information on changing synchronisation settings of base stations, see BSS Synchronisation.
100 DN9812243
BSS Integration
Id:0900d805807d4158Confidential
Initialising base stations
For instructions on changing the BTS site's synchronisation settings, see the relevant BTS documentation.
Further information
Example: Create a BCF according to the Abis time slot allocation shown in the table.
1. Create LAPD linksZDSE:B0001:BCSU,0:62,1:16,33-1,2;ZDSE:T0101:BCSU,0:0,1:16,33-1,0;ZDSE:T0102:BCSU,0:0,2:16,33-3,0;
2. Create BCFZEFC:1,P:DNAME=B0001;
3. Create BTS • ETSI:
ZEQC:BCF=1,BTS=1,NAME=BTS1:CI=1,BAND=900:NCC=0,BCC=0:MCC=214,MNC=1,LAC=1:;
• ANSI:ZEQC:BCF=1,BTS=1,NAME=CELL1:CI=1,BAND=1900:NCC=0,BCC=0:MCC=214,MNC=1,LAC=1:;
4. Create TRXsZERC:BTS=1,TRX=1::FREQ=100,TSC=0,PCMTSL=33-1:DNAME=T0001:SIGN=2,CH0=MBCCHC,CH1=NOTUSED;ZERC:BTS=1,TRX=2::FREQ=55,TSC=0,PCMTSL=33-3:DNAME=T0002:SIGN=1,CH0=NOTUSED;
The TRX parameters can be modified with the ERM command.
Further informationNext, attach the BCF software build to the BCF.
9.2 Attaching the BCF software build to the BCFBase station software is kept in the BSC's hard disks. There are 40 directories for BTS software builds and one directory for BTS hardware databases (see figure BTS software directories). Usually, only some of the directories are needed since the base stations can use the same builds with each other.
0 LINK MANAGEMENT
1 TRXSIG1 OMUSIG TCH.2 TCH.3 TRX 1
2 TCH.4 TCH.5 TCH.6 TCH.7
3 TRXSIG2 TCH.1 TCH.2 TCH.3 TRX 2
4 TCH.4 TCH.5 TCH.6 TCH.7
DN9812243 101
BSS Integration Initialising base stations
Id:0900d805807d4158Confidential
Figure 22 BTS software directories
Steps
1 Copy the BCF software build to the BSC's disks (IWX, IWY, IBC).Find an unused BCF software directory and copy the BCF software build to it from the floppy disk.
IWX, IWY, IBC
2 Create BTS software build (EWC).ZEWC:<build id>:MF=<master file name>,EXT=<master file extension>,SDIR=<subdirectory name>;
3 Set initial software build; optional (EWS).ZEWS:<site type>:<build id>;
4 Attach build to the BCF (EWA).If the Operation and Maintenance Unit (OMU) link is working, background downloading of the build to the base station is started. Otherwise, the build is only administratively attached to the BCF and the software is downloaded later.
ZEWA:<number of BCF>:BU:<build id>;
5 Activate the build (EWV).If the BCF is in unlocked state it is restarted as the build is activated. Otherwise, only the state of the build is changed to DEF.
ZEWV:<number of BCF>:BU;
6 Confirm the execution of the command.The program asks for a confirmation to execute the command. The command cuts all ongoing calls in the reseted BTS site. Confirm by YES (Y) or NO (N).
Further informationNext, attach the BTS hardware database to the BTS.
BTS SW files
AS8_8_14_0
ROOT
SCMANA BCF_PACK
PACK_0 PACK_39 HWDATA...
BTS SW files BTS HW databases
102 DN9812243
BSS Integration
Id:0900d805807d4158Confidential
Initialising base stations
9.3 Attaching the BTS hardware database to the BTS
t This is done only for Talk-family base stations.
The BTS hardware database contains the base station's hardware configuration. Hardware database files are kept in the BSC's hard disks in BCF_PACK\HWDATA directory as shown in figure BTS software directories.
Before you startBefore proceeding, you must have suitable hardware database files available. For infor-mation on how to prepare a BTS hardware database, see BTS documentation.
Steps
1 To implement this step, choose one of the following alternatives:
a If The BTS does not yet have a valid hardware database
Then
Once the BTS hardware configuration is available, copy it to the BSC.The database files are:
HWDATA_T.<ext> Database file in text format
HWDATAOM.<ext> Database file in binary format
b If The BTS already has a valid hardware database
Then
Upload the hardware database to the BSC (EVU).If the BTS already has a valid hardware database, it can be uploaded to the BSC instead of copying new files with the command EVU.
2 Create BCF hardware database (EVC).Once the hardware database files have either been copied or uploaded to the BSC, the database must be created.
ZEVC:<database id>:NAME=<file name>,EXT=<file extension>;
3 Attach hardware database to the BCF (EVA).ZEVA:<bcf identity>:<database id>;
4 To implement this step, choose one of the following alternatives:
a If The hardware database has already been downloaded to the BTS
Then
Activate the hardware database without downloading (EVV).ZEVV:<bcf identity>:PAS:NODL;
b If The hardware database is not in the flash
Then
DN9812243 103
BSS Integration Initialising base stations
Id:0900d805807d4158Confidential
Activate the hardware database with site reset (EVV).The Operation and Maintenace Unit (OMU) link must be operational before the downloading.
ZEVV:<bcf identity>:PAS:SITE;
c Activate the hardware database without site reset (EVV).After this command the hardware database is in the flash but not in use. Site reset is needed to take it into use:
ZEVV:<bcf identity>:PAS:NORST;
Further informationNext, take the base station into use.
9.4 Taking the base station into useIn this phase, the base station is taken into use by unlocking it.
Steps
1 Change status of BTS D-channels (DTC).Change the state of the Operation and Maintenance (OMU) link and the TRX links to WO-EX:
ZDTC:<D-channel link set name>:,WO;
2 Unlock the TRXs (ERS).If the higher level objects are already unlocked the transition from locked to unlocked causes a TRX reset in the BTS site. Otherwise, the reset is not done.
ZERS:BTS=<BTS identification>,TRX=<transceiver identification>:U;
3 Unlock the BTSs under the BCF (EQS).If the BCF is already unlocked the transition from locked to unlocked causes a BTS reset in the BTS site. Otherwise, the BTSs are not reset.
ZEQS:BTS=<BTS identification>:U;
4 Unlock the BCF (EFS).ZEFS:<BCF identification>:U;
Expected outcomeThe transition from locked to unlocked causes a BCF reset. While the BCF is resetting, all its components and the BCF itself are in BL-RST (blocked-reset) state. During that time, the BCF is not available for traffic nor controllable by MML.
Parameter Explanation
D-channel link set name Name of the LapD link.
104 DN9812243
BSS Integration
Id:0900d805807d4158Confidential
Initialising base stations
The reset is over when all its components and the BCF itself are in WO (working) state.
DN9812243 105
BSS Integration Testing BSS integration
Id:0900d805805cedf4Confidential
10 Testing BSS integrationBefore you startThe test requires one of each network element (BTS, BSC, MSC, and HLR), and in fault conditions a PCM/T1 analyser (PC with GSM Protocol Analyser to trace A/Abis mes-sages). All the network elements and connections must be operative and the network configuration valid.
Figure 23 The test arrangements
The test cases are described in a general level. For more detailed information, refer to BSC SW release material: BSC System Test Cases and BSC Release Test Cases.
For an overview, see Overview of BSS integration.
10.1 Testing local blocking of a TRXThe purpose of the test is to verify the correct working of the BSS in local blocking (OMU MMI) of a TRX
Steps
1 Check the status of the signalling network with a BSC MML.
2 Check current alarms in the system.
3 Check that the TRX and the BTS to be tested are in the working state and opera-tive.
4 Block the TRX locally from the BTS OMU MMI.
5 Unblock the TRX locally from the BTS OMU MMI.
6 Check any new alarms in the system.
Expected outcome
1. An alarm concerning a TRX block is raised.
BTSBSC
Abis
MS
MS
MS
BTS
Protocol Analyzerfor G.703 i/f
A and Abis monitor
A
TO MSC,HLR, VLR
TCSM
106 DN9812243
BSS Integration
Id:0900d805805cedf4Confidential
Testing BSS integration
2. When the TRX is blocked locally an announcement concerning this state is also sent to the BSC, and the BSC MML also shows that the TRX is blocked and not available for traffic.
10.2 Testing the supervision of the TCSM2 (ETSI/ANSI)The purpose of the test is to verify the correct working of the supervision of the TCSM2.
Steps
1 Verify that transmission is working correctly and there are no transmission alarms active in the BSC.
2 Check the settings of the TCSM2 with remote MML ZDDT.Use the command ZDDT.
3 Check that the TCSM2 hardware configuration matches the hardware in the racks.Use the service terminal command ZGT.
4 Cause a channel fault to the transcoder unit.Do this for example by pulling out a TR16 (ETSI) or TR12 (ANSI) plug-in unit.
5 Check any new alarms in the system.
Expected outcomeAlarm 2952 TRANSCODER PLUG-IN UNIT FAILURE is active.
10.3 Testing the supervision of the TCSM3i (ETSI/ANSI)The purpose of the test is to verify the correct working of the supervision of the TCSM3i.
Steps
1 Verify that transmission is working correctly and there are no transmission alarms active in the BSC.
2 Check the settings of the TCSM3i with remote MML ZDDT.Use the MML command ZDDT.
3 Check that the TCSM3i hardware configuration matches the actual hardware.Use the service terminal command ZGT.
4 Block one DSP unit.Use the following command:
DN9812243 107
BSS Integration Testing BSS integration
Id:0900d805805cedf4Confidential
ZUB:DSP,0;
5 Check any new alarms in the system.
Expected outcomeAlarm 3991 TR3 DSP LOCALLY BLOCKED is active.
You can unblock the DSP unit with the command ZUF:DSP,0;
10.4 Testing IMSI AttachThe purpose of the test is to verify the correct working of the BSS in IMSI attach.
Steps
1 Check the status of the signalling network with a BSC MML.
2 Check current alarms in the system.
3 Power up the mobile station.
4 Check any new alarms in the system.
Expected outcome
1. The mobile station finds the BTS.2. IMSI_ATTACH message is seen in the Abis interface.
10.5 Testing location updatingThe purpose of the test is to verify the correct working of the BSS in location updating.
Steps
1 Check the status of the signalling network with a BSC MML.
2 Check current alarms in the system.
3 Supply the PIN to the mobile station.
4 Check any new alarms in the system.
Expected outcomeThe mobile station finds the network and ends on service state.
10.6 Testing MS to MS callThe purpose of the test is to verify the correct working of the BSS in a basic call.
108 DN9812243
BSS Integration
Id:0900d805805cedf4Confidential
Testing BSS integration
Steps
1 Check the status of the signalling network with a BSC MML.
2 Check current alarms in the system.
3 Make a call from subscriber A (the calling subscriber) to subscriber B (the called subscriber).
4 Make subscriber B answer the call.
5 Verify speech quality.
6 Clear the call at subscriber A's mobile station.
7 Check any new alarms in the system.
Expected outcomeThe call is successful and speech quality is good.
10.7 Testing MS to MS call, B busyThe purpose of the test is to verify the correct working of the BSS in a basic call when subscriber B is busy.
Steps
1 Check the status of the signalling network with a BSC MML.
2 Check current alarms in the system.
3 Make a call from subscriber A to subscriber B (subscriber B is busy).
4 After observing the busy tone at subscriber A's MS, clear the call at subscriber A's MS.
5 Check that there are no hanging resources.
6 Check any new alarms in the system.
Expected outcomeSubscriber A receives the busy tone.
DN9812243 109
BSS Integration Testing BSS integration
Id:0900d805805cedf4Confidential
10.8 Testing MS to MS call, A subscriber IMSI detachThe purpose of the test is to verify the correct working of the BSS in a basic call when subscriber A makes IMSI detach during speech.
Steps
1 Check the status of the signalling network with a BSC MML.
2 Check current alarms in the system.
3 Make a call from subscriber A to subscriber B.
4 Answer the call at subscriber B's MS.
5 Make IMSI detach (subscriber A).
6 Check any new alarms in the system.
Expected outcome
1. There are no hanging resources.2. The call is set up as required and subscriber A releases the call.
10.9 Testing successful handover: free TCHsThe purpose of the test is to verify the correct working of the BSS in a successful han-dover, where free TCHs are available.
Steps
1 Check the status of the signalling network with a BSC MML.
2 Check current alarms in the system.
3 Check that there are free TCHs in the BTS where the subscriber A will move.
4 Make a call from subscriber A to subscriber B.
5 Answer the call at subscriber B's MS.
6 Make a handover to subscriber A.
7 Verify speech quality.
110 DN9812243
BSS Integration
Id:0900d805805cedf4Confidential
Testing BSS integration
8 Check any new alarms in the system.
Expected outcomeThe handover is successful and speech quality is good all the time.
10.10 Testing unsuccessful handover: no free TCHsThe purpose of the test is to verify the correct working of the BSS in an unsuccessful handover, where no free TCHs are available.
Steps
1 Check the status of the signalling network with a BSC MML.
2 Check current alarms in the system.
3 Make sure that there are no free TCHs in the BTS where subscriber A will move.
4 Make a call from subscriber A to subscriber B.
5 Answer the call at subscriber B's MS.
6 Make a handover attempt to subscriber A.
7 Check any new alarms in the system.
Expected outcomeThe handover fails and the call is released by the network unless the original channel is still adequate to continue the call.
10.11 Testing radio resource queuing in handoverThe purpose of the test is to verify the correct working of the BSS in a successful han-dover, where a radio resource has to be queued.
Steps
1 Check the status of the signalling network with a BSC MML.
2 Check current alarms in the system.
3 Make a call from subscriber A to subscriber B.
4 Answer the call at subscriber B's MS.
DN9812243 111
BSS Integration Testing BSS integration
Id:0900d805805cedf4Confidential
5 Reserve one TCH with one more MS and block other TCHs.
6 Make a handover attempt to subscriber A.
7 Release the occupied TCH for the handover attempt.
8 Check any new alarms in the system.
Expected outcomeThe handover is successful after queuing and the call continues.
112 DN9812243
BSS Integration
Id:0900d805805cedf7Confidential
Test logs for BSS integration
11 Test logs for BSS integrationWhile integrating the BSS, record confirmation on test execution and possible comments in the test logs.
Part of the logs can be used as a check list while testing.
BSC C number:
BSC name:
BSC Software release (xx.yy-zz):
TCSM2/TCSM3i C number:
TCSM2/TCSM3i Software release (xx.yy-zz):
BTS Software release:
Checked by:
Approved by:
Table 32 BSS specifications
Observations:
Corrective actions:
Checked by:
Date:
Table 33 Creating the A interface
DN9812243 113
BSS Integration Test logs for BSS integration
Id:0900d805805cedf7Confidential
Approved by:
Date:
Table 33 Creating the A interface (Cont.)
Observations:
Corrective actions:
Checked by:
Date:
Approved by:
Date:
Table 34 Creating the Abis interface
Observations:
Corrective actions:
Checked by:
Table 35 Initialising the base stations
114 DN9812243
BSS Integration
Id:0900d805805cedf7Confidential
Test logs for BSS integration
For an overview, see Overview of BSS integration.
Date:
Approved by:
Date:
Table 35 Initialising the base stations (Cont.)
TEST NUMBER:
Observations / used parameter values:
TESTING STATUS (OK/NOK):
Corrective actions/remarks:
Tested by:
Date:
Table 36 Testing BSS integration