boiler system

Post on 07-Mar-2016

9 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

sytem

TRANSCRIPT

  • Materi Training Boiler SystemBoiler systemBoiler House Diagram

  • Effects of flash steamMateri Training Boiler System Boiler system

  • High pressure steam boilerMateri Training Boiler System Boiler system

  • Materi Training Boiler SystemBoiler systemSteam Boiler AccessoriesBurner Gas Liquid SolidPressure Control Pressure Controller Safety Pressure Switch Safety ValveLevel Control Level Controller Safety Level control Level IndicatorFeeding Water Feed Water Pump Feed Water Control ValveBoiler Blow down Intermittend Blow Down Continuous Blow Down Main Valve + Steam SeparatorBoiler VentingEconomizerSuperheater

    steam boiler system

  • Influence of the boiler capacity on the low level switchpointMain Steam ValveMain steam valveLow level limiterLow level limiterSteam areaSteam areaFire tubeCombustion tubeShell boiler without steam productionShell boiler with steam productionMateri Training Boiler System Boiler system

  • Compact probe NRGT 26-1Materi Training Boiler System Boiler system

    Frequency driven feedwater control

    Feed

    water

    Steam

    4...20 mA

  • Comparison: Intermittent / Continuous

    High level -Alarm

    Pump Off

    Pump On

    Low level -AlarmHigh level-AlarmSet point

    Low level - alarmIntermittent with fixed switch pointsContinuous with variable switch pointsMateri Training Boiler System Boiler system

  • Continuous level controlHLLLLevel probe NRG 26HL-AlarmFeedwater pumpLL-AlarmIndicator URA-2eLevel controler NRR 2-2eFeedwater-Control valveMateri Training Boiler System Boiler systemHL

  • PressureVisibillityConductivity at 25CPH-value at 25CTotal hardnessIron (Fe)Copper (Cu)Silica (SiO2)Oxygen (O2)Oil/Grease (Turbidity)Organic matterUnitFeedwater fr Steam Boiler with TDS contentAuxiliary Water for Hot water boilersValueClear, no suspended solids see Not defined yet. See table 5-2 for Boiler water valuesTable 5.1 Feedwater for Steam Boiler & Hot Water BoilersMateri Training Boiler System Boiler system

  • Table 5.2 Boiler water for Steam Boiler & Hot Water BoilersUnitPressureVisibillityConductivity at 25CPH-value at 25CAcid capacity up to pH 8.2 Silica (SiO2)Phosphate (PO4)Organic matterBoiler water for steam boilerFeed water conductivity> 30S/cmFeed water cond 30S/cmBoiler waterfor HotwaterGeneratorsValueClear, no stable foamSee table 5-1Pressure depending, see picture 5-2Materi Training Boiler System Boiler system

  • Picture 5.2 Max. allowed conductivity, pressure depending Conductivity at 25COperating PressureMateri Training Boiler System Boiler system

  • Continuous BlowdownMateri Training Boiler System Boiler system

  • Intermittend Blowdown ValveNew blowdown valve Type PA 46Moveabel hand lever position adjustable in steps of 90Materi Training Boiler System Boiler system

  • Intermittend Blowdown MPA 46Materi Training Boiler System Boiler system

  • Hardness measures in Fresh waterMateri Training Boiler System Boiler system

  • Pressurized DearatorMateri Training Boiler System Boiler system

  • Blowdown VesselMateri Training Boiler System Boiler system

  • Flash VesselMateri Training Boiler System Boiler system

  • Condensate TankMateri Training Boiler System Boiler system

  • DesuperheaterMateri Training Boiler System Boiler system

  • DesuperheaterMateri Training Boiler System Boiler system

  • THANK YOUEND OF TRAINING SESSIONMateri Training AK3BUDepnaker-Pusat

top related