1

BASICS OF RP-HPLC AND HILIC

GEETHAANJALI VIJAYAKUMAR 13/07/2015

2

CHROMATOGRAPHY

• What is it? Physical separation method based on differential

migration of analytes in mobile phase as they move along a stationary phase.

• How does it work? Mixture – flushed through column – differential

migration over adsorptive material – separation by desorption.

Types of chromatography : column and planar.

3

RP - HPLC

• Mode of separation of components – primarily based on differences in hydrophobicity.

• Separation depends on the hydrophobic interaction of solute molecule from mobile phase to immobilized hydrophobic ligands (stationary phase) attached to a support.

4

• Solute – initially applied to sorbent (hydrophobic stationary phase) – eluted by increasing organic solvent concentration in mobile phase.

• Eluted in the order of increasing molecular hydrophobicity.

5

IMPORTANT REVERSE PHASE PARAMETERS

• Solvent (mobile phase ) Strength• Choice of Solvent• Mobile Phase pH• Silanol Activity• Mobile phase additives – generally TFA

6

Binding of peptide(A) and protein (B) to an RP-HPLC sorbent.

Ref: Aguilar, M. I. and Hearn, M. T. W. (1996) High resolution reversed phase high performance liquid chromatography of peptides and proteins.

7

RP-HPLC

ADVANTAGES• Widely used due its

flexibility and high resolution.

• Separation of proteins and peptides – both analytical and preparative.

DISADVANTAGES• High affinity towards the

protein, so that elution requires extreme conditions – denaturation of proteins.

• Very polar compounds – low retention – elute with aqueous eluent – unfavourable for MS.

8

HILIC

• Hydrophilic interaction chromatography – technique used to separate polar and/or basic components.

• RP HPLC – used for wide variety of components – but difficult for the analysis of small polar molecules. Here’s when HILIC is used.

9

• HILIC combines the characteristics of the 3 major methods in liquid

chromatography – reversed phase (RPC), normal phase (NPC) and ion chromatography (IC).

• Stationary phases (adsorbents) are mostly polar modifications of silica or polymers (SiOH, Amino, Diol etc) – like in NPC.

• Mobile phases (eluents) are mixtures of aqueous buffer systems and organic modifiers like acetonitrile or methanol – like in RPC.

• Fields of application include quite polar compounds as well as organic and inorganic ions – like in IC.

10

HILIC is NP chromatography of polar and ionic compounds under RP conditions.Ref : Hydrophilic interaction liquid chromatography (HILIC)—a powerful separation technique Bogusław Buszewski and Sylwia Noga

11

• Polar phase – when used with a mobile phase high in organic concentration, the more polar water preferentially adsorbs on the surface creating a semi-stagnant, water-rich stationary phase and a water depleted mobile phase.

• Polar analytes can then partition in to aqueous-enriched phase.

12

MECHANISM

• More polar nature of the eluent – No issues with the solubility of polar analytes.

• HILIC retention mechanism works on the basis that water adsorbs onto the stationary phase surface - becomes immobilised - analyte partitioning takes place between this and the bulk mobile phase. (liquid/liquid extraction system).

13

14

• Stationary phase for HILIC – silica• Side groups attached – silanol – acidic and

hydrophilic.• Interact with basic analytes through hydrogen

bonding/electrostatic interactions.

15

HYDROPHILIC PARTITIONING :AN AQUEOUS LAYER ALLOWS PARTITION BETWEEN HYDROPHILIC STATIONARY PHASE AND HYDROPHOBIC ELUTION BUFFER

16

SECONDARY INTERACTION :ELECTROSTATIC INTERACTION WITH CHARGED STATIONARY PHASE

17

18

ADVANTAGES OF HILIC

ADVANTAGES• Retention of hydrophilic

compounds that are difficult to retain by Reversed Phase Liquid Chromatography (RPLC).

DISADVANTAGES• Reliance on ACN – acetone

can be used as an alternative but UV detection – not possible at low wavelenghths.

19

ADVANTAGES• Low viscosity of eluents –

desirable for analysis – possible with HILIC where RP requires elevated temperatures.

• Compatibility of buffers used in LC- ESI- MS (presence of water as an eluting solvent favors ionization).

DISADVANTAGES• Solubility issues with some

analytes.

20

REFERENCES

• Aguilar, M. I. and Hearn, M. T. W. (1996) High resolution reversed phase high performance liquid chromatography of peptides and proteins.

• Advantages and Disadvantages of HILIC; a Brief Overview by James Heaton and Norman W. Smith.

• HILIC Chromatography: Theory and Method Development Practices David S. Bell.

21

QUESTIONS!!!!!!