awex - katalog - 2011 - 07 - 22
Post on 11-Jan-2017
236 Views
Preview:
TRANSCRIPT
-
infinity ainfinity b lovato nlovato pled eyetwins escape & escape-ledplexi ledtiger & tiger ledtiger p & tiger p ledtiger ds & tiger ds ledhelios & helios led (ip42)helios & helios led (ip65)helios p/helios p ledhelios ds & helios ds led (ip42)helios ds & helios ds led (ip65)helios power ledemxpanoramaskw & skw ledskw ds & skw ds ledviper-r & viper-sclassic & classic-silverclassic fwdublosquaretwister
13579
p. 11p. 13p. 14p. 15p. 17p. 18p. 19p. 20p. 21
p. 23
p. 24p. 25p. 26p. 27p. 28p. 29p. 30p. 31p. 33p. 34p. 35p. 36p. 37
quadroufohermeticaliderlider pluslider nimhlider atlider ntlinlinex uni ledcombo 5trubic monitoring systemcentral battery system - type cbscentral battery system - type cbmcentral battery system - type cbg 1500central battery system - type cblcentral battery system - type cbccentral battery system - type cbnemergency mode central lock systemaccessoriesmounting accessoriespictogramslist of termsmodules selection table to light sourceinformation to readernotes
p. 38p. 39p. 40p. 41p. 42p. 43p. 44p. 45p. 46p. 47p. 48p. 49p. 50p. 53p. 54p. 55p. 56p. 57p. 58p. 59p. 61p. 61p. 62p. 62p. 63p. 63p. 64
p.p.p.p.p.
-
infinity ainfinity b lovato nlovato pled eyetwins escape & escape-ledplexi ledtiger & tiger ledtiger p & tiger p ledtiger ds & tiger ds ledhelios & helios led (ip42)helios & helios led (ip65)helios p/helios p ledhelios ds & helios ds led (ip42)helios ds & helios ds led (ip65)helios power ledemxpanoramaskw & skw ledskw ds & skw ds ledviper-r & viper-sclassic & classic-silverclassic fwdublosquaretwister
13579
p. 11p. 13p. 14p. 15p. 17p. 18p. 19p. 20p. 21
p. 23
p. 24p. 25p. 26p. 27p. 28p. 29p. 30p. 31p. 33p. 34p. 35p. 36p. 37
quadroufohermeticaliderlider pluslider nimhlider atlider ntlinlinex uni ledcombo 5trubic monitoring systemcentral battery system - type cbscentral battery system - type cbmcentral battery system - type cbg 1500central battery system - type cblcentral battery system - type cbccentral battery system - type cbnemergency mode central lock systemaccessoriesmounting accessoriespictogramslist of termsmodules selection table to light sourceinformation to readernotes
p. 38p. 39p. 40p. 41p. 42p. 43p. 44p. 45p. 46p. 47p. 48p. 49p. 50p. 53p. 54p. 55p. 56p. 57p. 58p. 59p. 61p. 61p. 62p. 62p. 63p. 63p. 64
p.p.p.p.p.
-
infinity aredesigned version
15
0
300
300
15
0
15
0
300
18
0
max
1m
IFA-RIFA-S
IFA-C
1
1
1
3
3
3
2
2
2
1
1
1
3
3
3
2
2
2
type
LED
LIGHT SOURCECharacteristic
power [W]
type
CENTRAL BATTERYConfiguration of fitting
central bat.
CB
CB
CB
IFAC
IFAS
IFAR
type
STANDARDConfiguration of fitting
time [h] work
SE
SE
SE
SA
SA
SA
option
PT
PT
PT
RS
RS
RS
IFAC
IFAS
IFAR
type
AUTOTESTConfiguration of fitting
time [h]
SE
SE
SE
SA
SA
SA
work autotest
AT
AT
AT
IFAC
IFAS
IFAR 2,5
Dimensions of montage:- hole (a x b) - 60 x 335,- distance beatween ceiling and suspended ceiling - 150
a
b
h
universal emergencylighting fitting
Materials:silver polycarbonate body, other colours in option
Mounting:ceiling, rope slings
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesLED 2,5W diodesInsulation class IIProtection level IP 44Ambient temperature: 0C to +40CRecognition distance 30 mElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specificationsPN-EN 60598, PN-EN 1838Optional PT or RS
-
infinity aredesigned version
15
0
300
300
15
0
15
0
300
18
0
max
1m
IFA-RIFA-S
IFA-C
1
1
1
3
3
3
2
2
2
1
1
1
3
3
3
2
2
2
type
LED
LIGHT SOURCECharacteristic
power [W]
type
CENTRAL BATTERYConfiguration of fitting
central bat.
CB
CB
CB
IFAC
IFAS
IFAR
type
STANDARDConfiguration of fitting
time [h] work
SE
SE
SE
SA
SA
SA
option
PT
PT
PT
RS
RS
RS
IFAC
IFAS
IFAR
type
AUTOTESTConfiguration of fitting
time [h]
SE
SE
SE
SA
SA
SA
work autotest
AT
AT
AT
IFAC
IFAS
IFAR 2,5
Dimensions of montage:- hole (a x b) - 60 x 335,- distance beatween ceiling and suspended ceiling - 150
a
b
h
universal emergencylighting fitting
Materials:silver polycarbonate body, other colours in option
Mounting:ceiling, rope slings
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesLED 2,5W diodesInsulation class IIProtection level IP 44Ambient temperature: 0C to +40CRecognition distance 30 mElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specificationsPN-EN 60598, PN-EN 1838Optional PT or RS
-
IFB
infinity bredesigned version
type
LED
power [W]
2,5
universal emergencylighting fitting
Materials:silver polycarbonate body, other colours in option
Mounting:wall or dry-wall under plastering
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesLED 2,5 W diodesInsulation class IIProtection level IP 44Ambient temperature: 0C to +40CRecognition distance 30 mElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specificationsPN-EN 60598, PN-EN 1838Optional PT or RS
-
IFB
infinity bredesigned version
type
LED
power [W]
2,5
universal emergencylighting fitting
Materials:silver polycarbonate body, other colours in option
Mounting:wall or dry-wall under plastering
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesLED 2,5 W diodesInsulation class IIProtection level IP 44Ambient temperature: 0C to +40CRecognition distance 30 mElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specificationsPN-EN 60598, PN-EN 1838Optional PT or RS
-
lovato n redesigned version
500
1000
500
60
75
90
105
120135180150120
105
90
75
60
1500
20000 15 30
4545
30 15
I(0)=170cd/klm [cd/klm]
C0-C180 C90-C270
200
400
600
200
400
0 15 30
45
60
75
90
105
120
135150180150135
120
105
90
75
60
45
30 15
I(0)=77cd/klm [cd/klm]
C0-C180 C90-C270
L1 L2
h
2,5
3
3,5
4
4,5
5
6
7
8
8
10
10
11
11
12
12
10
8
19
22
24
25
27
28
29
30
29
5,5
5
4
3
2,5
2,5
2
2
2
12,5
13,5
14,5
15,5
16
15
14,5
13
2,5
2,5
2,5
2,5
2
2
2
2
2
11,5
11
10,5
10
10,5
10
8,5
7
4,5
7,5
8
8
8,5
8,5
8
7
7
7
16,5
18
19
20,5
21
20
20
15
10
2,5
3
3,5
4
4,5
5
6
7
8
2,5
3
3,5
4
4,5
5
6
7
8
2,5
3
3,5
4
4,5
5
6
7
8 12
type
LED
power [W]
3
universal emergencylighting fitting
Materials:white or silver polycarbonate body
Mounting:ceiling
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesPower Led 3W diodesInsulation class IIProtection level IP 41Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RSSA version only with extra box - see page with accesories
-
lovato n redesigned version
500
1000
500
60
75
90
105
120135180150120
105
90
75
60
1500
20000 15 30
4545
30 15
I(0)=170cd/klm [cd/klm]
C0-C180 C90-C270
200
400
600
200
400
0 15 30
45
60
75
90
105
120
135150180150135
120
105
90
75
60
45
30 15
I(0)=77cd/klm [cd/klm]
C0-C180 C90-C270
L1 L2
h
2,5
3
3,5
4
4,5
5
6
7
8
8
10
10
11
11
12
12
10
8
19
22
24
25
27
28
29
30
29
5,5
5
4
3
2,5
2,5
2
2
2
12,5
13,5
14,5
15,5
16
15
14,5
13
2,5
2,5
2,5
2,5
2
2
2
2
2
11,5
11
10,5
10
10,5
10
8,5
7
4,5
7,5
8
8
8,5
8,5
8
7
7
7
16,5
18
19
20,5
21
20
20
15
10
2,5
3
3,5
4
4,5
5
6
7
8
2,5
3
3,5
4
4,5
5
6
7
8
2,5
3
3,5
4
4,5
5
6
7
8 12
type
LED
power [W]
3
universal emergencylighting fitting
Materials:white or silver polycarbonate body
Mounting:ceiling
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesPower Led 3W diodesInsulation class IIProtection level IP 41Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RSSA version only with extra box - see page with accesories
-
400
800
1200
400
0 15 30
45
60
75
90
105
120135180150120
105
90
75
60
45
30 15
I(0)=184cd/klm [cd/klm]
C0-C180 C90-C270
200
400
600
200
400
0 15 30
45
60
75
90
105
120
135150180150135
120
105
90
75
60
45
30 15
I(0)=84cd/klm [cd/klm]
C0-C180 C90-C270
lovato p redesigned version
universal emergencylighting fitting
Materials:white polycarbonate body
Mounting:dry-wall or under plastering
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesPower LED 3W diodesInsulation class IIProtection level IP 20Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RS
L1 L2
h
Legend:SE - non maintained (dark)SA - maintained (light)RS - rubic monitoring systemAT - autotestCB - for central battery evg AC/DCLVPO - fitting Lovato p with optics for areaLVPC - fitting Lovato p with optics for escape routeL1 - mounting distance from wallL2 - distance between fittings
2,5
3
3,5
4
4,5
5
6
7
8
8
9
10
11
12
12
12
12
11
18
21
23
25
27
28
29
30
30
7,5
8
8
8,5
8,5
8,5
7,5
7,5
7,5
16,5
18
20
21,5
22
22
22
18
13
5,5
5
4,5
4
3,5
2,5
2
2
2
12,5
13,5
14,5
15,5
16,5
16
15
14
13
3
2,5
2,5
2,5
2
2
2
2
2
11,5
11
11
11
11
10
9
8
6
2,5
3
3,5
4
4,5
5
6
7
8
2,5
3
3,5
4
4,5
5
6
7
8
2,5
3
3,5
4
4,5
5
6
7
8
type
LED
power [W]
3
Dimension of montage- hole 82mm- distance between celling and suspended celling 150 mm
-
400
800
1200
400
0 15 30
45
60
75
90
105
120135180150120
105
90
75
60
45
30 15
I(0)=184cd/klm [cd/klm]
C0-C180 C90-C270
200
400
600
200
400
0 15 30
45
60
75
90
105
120
135150180150135
120
105
90
75
60
45
30 15
I(0)=84cd/klm [cd/klm]
C0-C180 C90-C270
lovato p redesigned version
universal emergencylighting fitting
Materials:white polycarbonate body
Mounting:dry-wall or under plastering
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesPower LED 3W diodesInsulation class IIProtection level IP 20Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RS
L1 L2
h
Legend:SE - non maintained (dark)SA - maintained (light)RS - rubic monitoring systemAT - autotestCB - for central battery evg AC/DCLVPO - fitting Lovato p with optics for areaLVPC - fitting Lovato p with optics for escape routeL1 - mounting distance from wallL2 - distance between fittings
2,5
3
3,5
4
4,5
5
6
7
8
8
9
10
11
12
12
12
12
11
18
21
23
25
27
28
29
30
30
7,5
8
8
8,5
8,5
8,5
7,5
7,5
7,5
16,5
18
20
21,5
22
22
22
18
13
5,5
5
4,5
4
3,5
2,5
2
2
2
12,5
13,5
14,5
15,5
16,5
16
15
14
13
3
2,5
2,5
2,5
2
2
2
2
2
11,5
11
11
11
11
10
9
8
6
2,5
3
3,5
4
4,5
5
6
7
8
2,5
3
3,5
4
4,5
5
6
7
8
2,5
3
3,5
4
4,5
5
6
7
8
type
LED
power [W]
3
Dimension of montage- hole 82mm- distance between celling and suspended celling 150 mm
-
led eyeredesigned version
Dimensions of montage- hole (a x b) - 33 x 66 mm- distance between celling and suspended celling 150 mm
a
b
h
L1 L2
h
universal, recessed ceiling-mountedemergency lighting fitting
Materials:stainless steel base, other colors in option
Mounting:dry-wall or under plastering
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesPower LED 3 x 1 W diodesInsulation class IProtection level IP20Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RS
3
-
led eyeredesigned version
Dimensions of montage- hole (a x b) - 33 x 66 mm- distance between celling and suspended celling 150 mm
a
b
h
L1 L2
h
universal, recessed ceiling-mountedemergency lighting fitting
Materials:stainless steel base, other colors in option
Mounting:dry-wall or under plastering
Specification:220-240V 50-60Hz power supplyElectronic impulse chargerMaximum charging time 12hNetwork power supply and battery charge LED indicatorHigh-temperature nickel-metal hydride batteriesPower LED 3 x 1 W diodesInsulation class IProtection level IP20Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RS
3
-
Mounting type
charging
-
Mounting type
charging
-
Dimensions of montage- hole (a x b) - 65 x 330 mm- distance between celling and suspended celling - 110 mm
a
b
h
-
Dimensions of montage- hole (a x b) - 65 x 330 mm- distance between celling and suspended celling - 110 mm
a
b
h
-
In option under plastering clips - see page with accessories
LED indicator
-
In option under plastering clips - see page with accessories
LED indicator
-
universal, two-sided emergency lighting fitting
Materials:white polycarbonate bodytransparent polycarbonate cover, plexi glass
Mounting:ceiling, dry-wall or under plastering
Specification:230V 50Hz power supplyMaximum charging time 24 hoursNetwork power supply and battery charge LED indicatorHigh-temperature nickiel-cadmium batteriesInsulation class IIProtection level IP 22Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RSIn option under plastering clips - see page with accessories
universal, two-sided emergency lighting fitting
Materials:white polycarbonate bodyopal polycarbonate cover
Mounting:ceiling, dry-wall or under plastering
Specification:230V 50Hz power supplyMaximum charging time 24 hoursNetwork power supply and battery charge LED indicatorHigh-temperature nickiel-cadmium batteriesInsulation class IIProtection level IP 22Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 20 mConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RSIn option under plastering clips - see page with accessories
-
universal, two-sided emergency lighting fitting
Materials:white polycarbonate bodytransparent polycarbonate cover, plexi glass
Mounting:ceiling, dry-wall or under plastering
Specification:230V 50Hz power supplyMaximum charging time 24 hoursNetwork power supply and battery charge LED indicatorHigh-temperature nickiel-cadmium batteriesInsulation class IIProtection level IP 22Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RSIn option under plastering clips - see page with accessories
universal, two-sided emergency lighting fitting
Materials:white polycarbonate bodyopal polycarbonate cover
Mounting:ceiling, dry-wall or under plastering
Specification:230V 50Hz power supplyMaximum charging time 24 hoursNetwork power supply and battery charge LED indicatorHigh-temperature nickiel-cadmium batteriesInsulation class IIProtection level IP 22Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 20 mConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RSIn option under plastering clips - see page with accessories
-
LED indicatorLED indicator
-
LED indicatorLED indicator
-
p. 23 p. 24
Fluorescent lamp T5 8W, compact lamp 11W or led 1,2W diodes
LED indicator
-
p. 23 p. 24
Fluorescent lamp T5 8W, compact lamp 11W or led 1,2W diodes
LED indicator
-
universal, one-sided emergency lighting fitting for high altitiudes
Materials:white polycarbonate bodytransparent polycarbonate cover
Mounting: ceiling
Specification:220-240 V 50-60Hz power supplyElectronic impulse charger
Network power supply and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesPower LED 3 x 1 W diodesInsulation class IIProtection level IP 65 or 42 (depends on the model) Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional PT or RS
C0-C180 C90-C270
I(0)=1943cd/klm [cd/klm]
90
75
60
45
30
15 0 15
90
75
60
45
30
400400
800800
12001200
16001600
20002000
BZ1 =100%
L1 L2
h
height
meters
8
8,5
9
9,5
10
10,5
11
11,5
12
4,5
4,5
4,5
4,5
4,5
4,5
4,5
4,5
4,5
8,5
8,5
9
9
9,5
9,5
9,5
9,5
9,5
42
type
HW
HWE
CENTRAL BATTERYConfiguration of fitting
central bat.
CB
CB
type
HW
HWE
STANDARDConfiguration of fitting
time [h]
1
1
2
2
3
3
work
SE
SE
SA
SA
option
PT
PT
RS
RS
type
HW
HWE
AUTOTESTConfiguration of fitting
time [h]
1
1
2
2
3
3
autotest
SE
SE
SA
SA
work
AT
AT
type
LIGHT SOURCECharacteristic
power [W]
LED
Legend:SE - non maintained (dark)SA - maintained (light)PT - manual test buttonRS - rubic monitoring systemAT - autotestCB - for central battery evg AC/DCHW - fitting helios power led IP 65HWE - fitting helios power led IP 42L1 - mounting distance from wall
L2 - distance between fittings
p. 26
Charging time 12h
helios power led
3
-
universal, one-sided emergency lighting fitting for high altitiudes
Materials:white polycarbonate bodytransparent polycarbonate cover
Mounting: ceiling
Specification:220-240 V 50-60Hz power supplyElectronic impulse charger
Network power supply and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesPower LED 3 x 1 W diodesInsulation class IIProtection level IP 65 or 42 (depends on the model) Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional PT or RS
C0-C180 C90-C270
I(0)=1943cd/klm [cd/klm]
90
75
60
45
30
15 0 15
90
75
60
45
30
400400
800800
12001200
16001600
20002000
BZ1 =100%
L1 L2
h
height
meters
8
8,5
9
9,5
10
10,5
11
11,5
12
4,5
4,5
4,5
4,5
4,5
4,5
4,5
4,5
4,5
8,5
8,5
9
9
9,5
9,5
9,5
9,5
9,5
42
type
HW
HWE
CENTRAL BATTERYConfiguration of fitting
central bat.
CB
CB
type
HW
HWE
STANDARDConfiguration of fitting
time [h]
1
1
2
2
3
3
work
SE
SE
SA
SA
option
PT
PT
RS
RS
type
HW
HWE
AUTOTESTConfiguration of fitting
time [h]
1
1
2
2
3
3
autotest
SE
SE
SA
SA
work
AT
AT
type
LIGHT SOURCECharacteristic
power [W]
LED
Legend:SE - non maintained (dark)SA - maintained (light)PT - manual test buttonRS - rubic monitoring systemAT - autotestCB - for central battery evg AC/DCHW - fitting helios power led IP 65HWE - fitting helios power led IP 42L1 - mounting distance from wall
L2 - distance between fittings
p. 26
Charging time 12h
helios power led
3
-
p. 27 p. 28
LED indicatorLED indicator
Fluorescent lamp T5 8W or compact lamp 11W
-
p. 27 p. 28
LED indicatorLED indicator
Fluorescent lamp T5 8W or compact lamp 11W
-
p. 29 p. 30
-
p. 29 p. 30
-
p. 32p. 31
universal, one-sided emergency lighting fitting
Materials:steel sheet base painted silver or white,
other colours in options
Mounting:wall, ceiling, optional dry-wall or under plastering
Specification:230V 50Hz power supplyCharging time 24 hoursNetwork power supply and battery charge LED indicatorHigh-temperature nickiel-cadmium batteries
Power LED 3 x 1 W diodesInsulation class IProtection level IP 20Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 25mConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RS
3
LED indicator
-
p. 32p. 31
universal, one-sided emergency lighting fitting
Materials:steel sheet base painted silver or white,
other colours in options
Mounting:wall, ceiling, optional dry-wall or under plastering
Specification:230V 50Hz power supplyCharging time 24 hoursNetwork power supply and battery charge LED indicatorHigh-temperature nickiel-cadmium batteries
Power LED 3 x 1 W diodesInsulation class IProtection level IP 20Ambient temperature: 0C to +40CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 25mConnecting clips 3 x 2,5 mmCompatibility with standard specifications PN-EN 60598, PN-EN 1838Optional RS
3
LED indicator
-
p. 33 p. 34
LED indicator LED indicator
-
p. 33 p. 34
LED indicator LED indicator
-
p. 35 p. 36
LED indicator LED indicator
-
p. 35 p. 36
LED indicator LED indicator
-
p. 37 p. 38
LED indicator
LED indicator
-
p. 37 p. 38
LED indicator
LED indicator
-
p. 39 p. 40
90 140
113
A
B
36W
18W
T8
58W
700
350
A
900
1x36 / 2x36
1x18 / 2x18
hermetica
1x58 / 2x58
1280
670
B
1580
LED indicator
-
p. 39 p. 40
90 140
113
A
B
36W
18W
T8
58W
700
350
A
900
1x36 / 2x36
1x18 / 2x18
hermetica
1x58 / 2x58
1280
670
B
1580
LED indicator
-
Conversion kit
Technical data:Power suply 220-240 VAC/50-60 HzPower of fluorecent lamp: 6 80 WAmbient temperature (t ) 0 +55CaOperation temperature (t ) 0 +70CcBatteries used: high temeperature maintained free NiCd HTBattery package voltage 3,6 V, 4,8 V, 6,0 V and capaticy 1,5 4,0 Ah (depense on the model)Electronic impulse chargerMaximum current of battery discharge
-
Conversion kit
Technical data:Power suply 220-240 VAC/50-60 HzPower of fluorecent lamp: 6 80 WAmbient temperature (t ) 0 +55CaOperation temperature (t ) 0 +70CcBatteries used: high temeperature maintained free NiCd HTBattery package voltage 3,6 V, 4,8 V, 6,0 V and capaticy 1,5 4,0 Ah (depense on the model)Electronic impulse chargerMaximum current of battery discharge
-
p. 43 p. 44
Ni-Cd 3,6V 2,5Ah
Ni-Cd 3,6V 4Ah
Ni-Cd 4,8V 2,5Ah
Ni-Cd 4,8V 4Ah
Ni-Cd 3,6V 2,5Ah
Ni-Cd 3,6V 4Ah
Ni-Cd 4,8V 2,5Ah
Ni-Cd 4,8V 4Ah
Ni-Cd 3,6 V 2,5 Ah
-
p. 43 p. 44
Ni-Cd 3,6V 2,5Ah
Ni-Cd 3,6V 4Ah
Ni-Cd 4,8V 2,5Ah
Ni-Cd 4,8V 4Ah
Ni-Cd 3,6V 2,5Ah
Ni-Cd 3,6V 4Ah
Ni-Cd 4,8V 2,5Ah
Ni-Cd 4,8V 4Ah
Ni-Cd 3,6 V 2,5 Ah
-
p. 45 p. 46
NiMh 6V 1,5 Ah
NiMh 6V 2,5 Ah
NiMh 6V 4,0 Ah
Electronic impulse chargerMax. charging time 12h
NiMh 6V 1,5 Ah
NiMh 6V 2,5 Ah
NiMh 6V 4,0 Ah
Electronic impulse chargerMax. charging time 12h
NiMh
Ni-Cd battery in option Ni-Cd battery in option
-
p. 45 p. 46
NiMh 6V 1,5 Ah
NiMh 6V 2,5 Ah
NiMh 6V 4,0 Ah
Electronic impulse chargerMax. charging time 12h
NiMh 6V 1,5 Ah
NiMh 6V 2,5 Ah
NiMh 6V 4,0 Ah
Electronic impulse chargerMax. charging time 12h
NiMh
Ni-Cd battery in option Ni-Cd battery in option
-
uni led
Universal conversion kit for LED diodes
Technical data:220-240V 50/60Hz power supply170 - 260VDC power supply12 VDC output voltageMaximum charge time 12 hBattery used: high temperature, maintained - free NiMh HTPower Led diodes 1x3WPower Led diodes 2x1WPower Led diodes 3x1WLed diodes 1,2WLed diodes 12VDC to 3,5WAmbient temperarure (ta): 0 ... + 50COperation temperature (tc): 0... + 70CProtection level IP 20Insulation class IIThe section of attached wires 0,5 - 1,5mmOptional AT or RSNi-Cd battery in option
Side
Bottom
General supplier of voltage-current type, assigned for power supply of led sources of flight.
The supplier is to be used in the systems of central battery as well as a simple supplier.
The maximal wattage of the led source of light connected to the supplier is 3,5 W with the voltage 12 VDC. The supplier has fuses both at the side of power supply and exit circuit. Uniwersal maintained/ non maintained version.
Universal maintained (SA) / non-maintained version (SE)
code power work battery
Ni-Mh/Ni-Cd 3,6 V 1,5 Ah
Ni-Mh/Ni-Cd 3,6 V 2,5 Ah
Ni-Mh/Ni-Cd 3,6 V 4,0 Ah
UL/1
UL/2
UL/3
1W - 3W
1W - 3W
1W - 3W
p. 47 p. 48
NiMh 6V 1,5 Ah
NiMh 6V 2,5 Ah
NiMh 6V 4,0 Ah
Electronic impulse chargerMax. charging time 12h
NiMh
Ni-cd battery in option
-
uni led
Universal conversion kit for LED diodes
Technical data:220-240V 50/60Hz power supply170 - 260VDC power supply12 VDC output voltageMaximum charge time 12 hBattery used: high temperature, maintained - free NiMh HTPower Led diodes 1x3WPower Led diodes 2x1WPower Led diodes 3x1WLed diodes 1,2WLed diodes 12VDC to 3,5WAmbient temperarure (ta): 0 ... + 50COperation temperature (tc): 0... + 70CProtection level IP 20Insulation class IIThe section of attached wires 0,5 - 1,5mmOptional AT or RSNi-Cd battery in option
Side
Bottom
General supplier of voltage-current type, assigned for power supply of led sources of flight.
The supplier is to be used in the systems of central battery as well as a simple supplier.
The maximal wattage of the led source of light connected to the supplier is 3,5 W with the voltage 12 VDC. The supplier has fuses both at the side of power supply and exit circuit. Uniwersal maintained/ non maintained version.
Universal maintained (SA) / non-maintained version (SE)
code power work battery
Ni-Mh/Ni-Cd 3,6 V 1,5 Ah
Ni-Mh/Ni-Cd 3,6 V 2,5 Ah
Ni-Mh/Ni-Cd 3,6 V 4,0 Ah
UL/1
UL/2
UL/3
1W - 3W
1W - 3W
1W - 3W
p. 47 p. 48
NiMh 6V 1,5 Ah
NiMh 6V 2,5 Ah
NiMh 6V 4,0 Ah
Electronic impulse chargerMax. charging time 12h
NiMh
Ni-cd battery in option
-
Ni-Cd 6 V 1,5 Ah
Ni-Cd 6 V 2,5 Ah
Ni-Cd 6 V 4 Ah
p. 49 p. 50
Expansion within the standard unit up to 1000 luminaresExpansion of the system with one control unit up to 10,000
Fluorescent T8 and compact 4 pins lamps
-
Ni-Cd 6 V 1,5 Ah
Ni-Cd 6 V 2,5 Ah
Ni-Cd 6 V 4 Ah
p. 49 p. 50
Expansion within the standard unit up to 1000 luminaresExpansion of the system with one control unit up to 10,000
Fluorescent T8 and compact 4 pins lamps
-
p. 52p. 51
Specyfication to Rubic TP central unit:Standard monitoring of 500 luminares luminaresControl of the system with other C-RUBIC control unitRecord of all made tests on SD cardLCD display with touch screen 5.7"230C 50 Hz power supplyCharging time - 12hCommunication via the cable screen 2 x 0,8 mmPower via the calbe 3 x 1,5 mmDistanse from the central unit to the furthest luminare - 1200 mPossibility to extend the distance communication cable for antoher 1200 meters with a signal amplifiler RPT (quantity of amplifiers on 1 network is unlimited)USB connector for communication with the control unitNight operationOwn power supply (battery)Possibility of group programmingCooperation with LED luminares
rubic system tp
Rubic TD central unit has its own wireless adapter with the battery LiFePO4 that enables its normal operation during a power failure. Being adapted for use with emergency lighting made in LED technology, the whole system is energy efficient and eco. Its widely known that modern highly efficient LEDs are more and more often used in emergency lighting, and the AWEX central unit of new generation is perfectly suited to this.
Standard central unit can monitor 500 fittings. Distance from the central to the furthest luminaire can be up to 1220 m but its possible to extend the distance communication cable for another 1200 meters with a signal amplifier RPT (quantity of amplifiers in 1 network is unlimited).Graphic visualization of the system: the previous application allowed only that type of system visualization which didnt give the straight information about the localization of the luminaire but only her logical localization in the system. Now its very easy to obtain the information about the physical localization of the luminaire. The application allows to upload the building plans into the system and mark emergency lighting luminaires on them. A state of each luminaire is indicated with a specified color of representing it pictogram.
The undeniable advantage is the possibility to switch intuitively between the visualization known from the previous version of application and visualization on the building plan.
USB/Ethernet the application can communicate with the central unit through USB or UDP. In this first option the computer must be placed near the central unit because of the
limit of USB standard. The more interesting option is connection to the LAN. It enables access to the central unit from any computer in the network.
ATTENTION: only one connection is possible. Offline operation: application allows to create a whole system configuration at an users desk without necessity of connecting to Rubic system. Such configuration may be uploaded to the system installed in the building, simultaneously all errors reported by the system during configuration process are recorded.
-
p. 52p. 51
Specyfication to Rubic TP central unit:Standard monitoring of 500 luminares luminaresControl of the system with other C-RUBIC control unitRecord of all made tests on SD cardLCD display with touch screen 5.7"230C 50 Hz power supplyCharging time - 12hCommunication via the cable screen 2 x 0,8 mmPower via the calbe 3 x 1,5 mmDistanse from the central unit to the furthest luminare - 1200 mPossibility to extend the distance communication cable for antoher 1200 meters with a signal amplifiler RPT (quantity of amplifiers on 1 network is unlimited)USB connector for communication with the control unitNight operationOwn power supply (battery)Possibility of group programmingCooperation with LED luminares
rubic system tp
Rubic TD central unit has its own wireless adapter with the battery LiFePO4 that enables its normal operation during a power failure. Being adapted for use with emergency lighting made in LED technology, the whole system is energy efficient and eco. Its widely known that modern highly efficient LEDs are more and more often used in emergency lighting, and the AWEX central unit of new generation is perfectly suited to this.
Standard central unit can monitor 500 fittings. Distance from the central to the furthest luminaire can be up to 1220 m but its possible to extend the distance communication cable for another 1200 meters with a signal amplifier RPT (quantity of amplifiers in 1 network is unlimited).Graphic visualization of the system: the previous application allowed only that type of system visualization which didnt give the straight information about the localization of the luminaire but only her logical localization in the system. Now its very easy to obtain the information about the physical localization of the luminaire. The application allows to upload the building plans into the system and mark emergency lighting luminaires on them. A state of each luminaire is indicated with a specified color of representing it pictogram.
The undeniable advantage is the possibility to switch intuitively between the visualization known from the previous version of application and visualization on the building plan.
USB/Ethernet the application can communicate with the central unit through USB or UDP. In this first option the computer must be placed near the central unit because of the
limit of USB standard. The more interesting option is connection to the LAN. It enables access to the central unit from any computer in the network.
ATTENTION: only one connection is possible. Offline operation: application allows to create a whole system configuration at an users desk without necessity of connecting to Rubic system. Such configuration may be uploaded to the system installed in the building, simultaneously all errors reported by the system during configuration process are recorded.
-
p. 53 p. 54
central battery systemtype: CBS
The Central battery system type CBS is constructed in accordance with the requirements of the standards VDE 0108 and PN-EN 50171. CBS System belongs to a group of systems of a limited load (LPS), preserving all CBN properties. Offers various possibilities of the inclusion of safety lighting concept to building lighting and direct plug in of normal lighting. There are two options of the systems depending on the load output, respectively 4 kW and 8kW.
The system features:5 work modes, different modes on a single circuit,monitoring of individual fittings,zoning possibility,visualization possibility, monitoring via Ethernet,programming of a single fitting possibility,expandability of the system of substations.
Technical specification
Voltage
Charger
Output voltage
Output circuumber
Ambient temperature
The integrity of enclosure
Safety class
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
Typ D - three-phase power 400V 50Hz
230 AC / 216V DC
4 kW version: 1 - 20
4 kW version: 21 - 40
0C - 40C
IP 21
I
RAL 7035
* Standard cabinets shown above. Special projects on demand at extra charge.
central battery systemtype: CBM
Central battery system type CBM is constructed in accordance with the requirements of the standards VDE 0108 and PN-EN 50171. The system allows to monitor groups of circuits DS, BS, and by applying relevant modules also circuits and fittings. The system is controlled and programmed by the SLC microprocessor controls module.
SLC microprocessor control module with LCD panelloading and supercharging device of IU characteristics with temperature compensationgroup moduleoutput circuits terminalsZLT modulephases loss sensor
Additional optional items:circuits monitoring modulefittings monitoring moduleMP 500 and MP 4A switching modulesreports and tests protocols printerPZS panel remotesubstationssubstations with E30 function
Technical specification
Voltage
Charger
Output voltage
Ambient temperature
The integrity of enclosure
Safety class
Type of cabinet
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
Typ D - tree-phase power 400V 50 Hz
230 AC / 216V DC
0C - 40C
IP 21
I
STK, NL
RAL 7035
* Standard cabinets shown above. Special projects on demand at extra charge.
Casing type Cabinet type Battery part dimensionsL x W x D (mm)
Cabinet dimensionsL x W x D (mm)
Max modules number output circuits protections number
STK 8.20 Combi 600x550x3801800x800x450 15 11
STK 8.21 Combi 600x750x5501800x800x600 35 26
STK 9.20 Combi 800x550x5502000x900x600 30 22
STK 9.21 Combi 800x850x5502000x900x600 41 30
STK 12.21S Combi 800x750x5502000x800x600 50 33
NL 3
NL 8.20
NL 9.21
Standard
Standard
Standard
1200x600x430
1800x600x450
1800x900x600
30
45
90
22
33
69
NL 5.21
NL 8.21
Standard
Standard
1400x800x600
1800x800x600
57
79
43
60
DO1 / DO2 Automat
-
p. 53 p. 54
central battery systemtype: CBS
The Central battery system type CBS is constructed in accordance with the requirements of the standards VDE 0108 and PN-EN 50171. CBS System belongs to a group of systems of a limited load (LPS), preserving all CBN properties. Offers various possibilities of the inclusion of safety lighting concept to building lighting and direct plug in of normal lighting. There are two options of the systems depending on the load output, respectively 4 kW and 8kW.
The system features:5 work modes, different modes on a single circuit,monitoring of individual fittings,zoning possibility,visualization possibility, monitoring via Ethernet,programming of a single fitting possibility,expandability of the system of substations.
Technical specification
Voltage
Charger
Output voltage
Output circuumber
Ambient temperature
The integrity of enclosure
Safety class
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
Typ D - three-phase power 400V 50Hz
230 AC / 216V DC
4 kW version: 1 - 20
4 kW version: 21 - 40
0C - 40C
IP 21
I
RAL 7035
* Standard cabinets shown above. Special projects on demand at extra charge.
central battery systemtype: CBM
Central battery system type CBM is constructed in accordance with the requirements of the standards VDE 0108 and PN-EN 50171. The system allows to monitor groups of circuits DS, BS, and by applying relevant modules also circuits and fittings. The system is controlled and programmed by the SLC microprocessor controls module.
SLC microprocessor control module with LCD panelloading and supercharging device of IU characteristics with temperature compensationgroup moduleoutput circuits terminalsZLT modulephases loss sensor
Additional optional items:circuits monitoring modulefittings monitoring moduleMP 500 and MP 4A switching modulesreports and tests protocols printerPZS panel remotesubstationssubstations with E30 function
Technical specification
Voltage
Charger
Output voltage
Ambient temperature
The integrity of enclosure
Safety class
Type of cabinet
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
Typ D - tree-phase power 400V 50 Hz
230 AC / 216V DC
0C - 40C
IP 21
I
STK, NL
RAL 7035
* Standard cabinets shown above. Special projects on demand at extra charge.
Casing type Cabinet type Battery part dimensionsL x W x D (mm)
Cabinet dimensionsL x W x D (mm)
Max modules number output circuits protections number
STK 8.20 Combi 600x550x3801800x800x450 15 11
STK 8.21 Combi 600x750x5501800x800x600 35 26
STK 9.20 Combi 800x550x5502000x900x600 30 22
STK 9.21 Combi 800x850x5502000x900x600 41 30
STK 12.21S Combi 800x750x5502000x800x600 50 33
NL 3
NL 8.20
NL 9.21
Standard
Standard
Standard
1200x600x430
1800x600x450
1800x900x600
30
45
90
22
33
69
NL 5.21
NL 8.21
Standard
Standard
1400x800x600
1800x800x600
57
79
43
60
DO1 / DO2 Automat
-
p. 55 p. 56
central battery systemtype: CBG1500
The System of battery group type CBG 1500 is equipped with all necessary for the proper functioning of the installation devices for loading, switching and monitoring. The system charger, consisting of the loading and supercharging systems, provides batteries loading in accordance with the PN 50 171. In the upper part of the casing there are readily available on DIN rail three-row connectors to connect linear circuits. The system is intended to power supply 4, 8, 12, 16 or 20 final circuits with a total capacity of not more than 1500W for time sustain of 1 hour or 500W for time maintaining 3 h. Using TWIN technologies, it is possible to install fittings in three modes of operation on a single circuit. The system is of particular use to power the LED luminaires and low wattage luminaires.
Standard equipment of the cabinet consists of the following elements:loading and supercharging devices of IU characteristics,linear modules NLE 4/220,SLC controller and monitoring devices,ZLT module,enter potential modules or no potential modules - optionally.
Technical specification
Voltage
Charger
Output voltage
Power
Output circuumber
Ambient temperature
The integrity of enclosure
Safety class
Cabinet dimensionsL x W x D (mm)
Battery part dimensionsL x W x D (mm)
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
230 AC / 216V DC
Up to 1500 W - emergency time maintaining 1h
Up to 500 W - emergency time maintaining 5h
4 - 20
0C - 40C
IP 21
I
1200x600x430
190x570x360 (the cabinet consist of two shelves)
RAL 7035
* Standard cabinets shown above. Special projects on demand at extra charge.
central battery systemtype: CBL
Central emergency lighting system CBL has all necessary for the proper functioning of the installation devices forloading, switching and monitoring. Charger system, consisting of the loading and supercharging devices, providesbatteries loading in accordance with the PN 50 171. There are produced three types of cabinets adapted to install upto 20, 32 and 44 final circuits. In the upper part of the casing there are readily available on DIN rail three-rowconnectors to connect linear circuits.
Standard equipment consists of the following elements:control panel cover,loading and supercharging devices of IU characteristics,linear modules NLE 4/220,SLC controller and monitoring devices,enter potential modules or no potential modules,compact cabinet measurements 1800x800x600mm,ZLT module,the printer optionally.
Typ
CBL 20
CBL 32
CBL 20
Equioment
Charger max. output current: 5A5 modules for linear type NLE4/220 (max 20 circuits)Enter potential modules or no potential modules LSM typeCasing consisting of two parts with 3 shelves on batteriesDimensions: 1800x800x600 mm
Charger max. output current: 8A8 linear type modules NLE4/220 (max 32 circuits)Enter potential modules or no potential modules LSM typeCasing consisting of two parts with 3 shelves on batteriesDimensions: 1800x800x600 mm
Charger max. output current: 8A11 modules for linear type NLE4/220 (max 44 circuits)Enter potential modules or no potential modules LSM typeCasing consisting of two parts with
Notice:CBL systems are also available with TWIN technology* Standard cabinets shown above. Special projects on demand at extra charge.
-
p. 55 p. 56
central battery systemtype: CBG1500
The System of battery group type CBG 1500 is equipped with all necessary for the proper functioning of the installation devices for loading, switching and monitoring. The system charger, consisting of the loading and supercharging systems, provides batteries loading in accordance with the PN 50 171. In the upper part of the casing there are readily available on DIN rail three-row connectors to connect linear circuits. The system is intended to power supply 4, 8, 12, 16 or 20 final circuits with a total capacity of not more than 1500W for time sustain of 1 hour or 500W for time maintaining 3 h. Using TWIN technologies, it is possible to install fittings in three modes of operation on a single circuit. The system is of particular use to power the LED luminaires and low wattage luminaires.
Standard equipment of the cabinet consists of the following elements:loading and supercharging devices of IU characteristics,linear modules NLE 4/220,SLC controller and monitoring devices,ZLT module,enter potential modules or no potential modules - optionally.
Technical specification
Voltage
Charger
Output voltage
Power
Output circuumber
Ambient temperature
The integrity of enclosure
Safety class
Cabinet dimensionsL x W x D (mm)
Battery part dimensionsL x W x D (mm)
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
230 AC / 216V DC
Up to 1500 W - emergency time maintaining 1h
Up to 500 W - emergency time maintaining 5h
4 - 20
0C - 40C
IP 21
I
1200x600x430
190x570x360 (the cabinet consist of two shelves)
RAL 7035
* Standard cabinets shown above. Special projects on demand at extra charge.
central battery systemtype: CBL
Central emergency lighting system CBL has all necessary for the proper functioning of the installation devices forloading, switching and monitoring. Charger system, consisting of the loading and supercharging devices, providesbatteries loading in accordance with the PN 50 171. There are produced three types of cabinets adapted to install upto 20, 32 and 44 final circuits. In the upper part of the casing there are readily available on DIN rail three-rowconnectors to connect linear circuits.
Standard equipment consists of the following elements:control panel cover,loading and supercharging devices of IU characteristics,linear modules NLE 4/220,SLC controller and monitoring devices,enter potential modules or no potential modules,compact cabinet measurements 1800x800x600mm,ZLT module,the printer optionally.
Typ
CBL 20
CBL 32
CBL 20
Equioment
Charger max. output current: 5A5 modules for linear type NLE4/220 (max 20 circuits)Enter potential modules or no potential modules LSM typeCasing consisting of two parts with 3 shelves on batteriesDimensions: 1800x800x600 mm
Charger max. output current: 8A8 linear type modules NLE4/220 (max 32 circuits)Enter potential modules or no potential modules LSM typeCasing consisting of two parts with 3 shelves on batteriesDimensions: 1800x800x600 mm
Charger max. output current: 8A11 modules for linear type NLE4/220 (max 44 circuits)Enter potential modules or no potential modules LSM typeCasing consisting of two parts with
Notice:CBL systems are also available with TWIN technology* Standard cabinets shown above. Special projects on demand at extra charge.
-
p. 57 p. 58
central battery systemtype: CBN
The Central battery system type CBN is constructed in accordance with the requirements of the standards VDE 0108and PN-EN 50171. The CBN System offers various possibilities of the inclusion of safety lighting concept to buildinglighting and direct plug in of normal lighting, lack of any restrictions in planning a replacement network and plenty ofthe options.
The system features:5 work modes, different modes on a single circuit,monitoring of individual fittings,zoning possibility,visualization possibility, monitoring via Ethernet,programming of a single fitting possibility,expandability of the system of substations.
Technical specification
Voltage
Charger
Output circut number
Output voltage
Ambient temperature
The integrity of enclosure
Safety class
Type of cabinet
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
Typ D - tree-phase power 400V 50 Hz
Up to 40
230 AC / 216V DC
0C - 40C
IP 21
I
STK, NL
RAL 7035
* Standard cabinets shown above. Special projects on demand at extra charge.
Casing type SKM numberCabinet dimensionsL x W x D (mm)
IOM number
STK 8.20 101800x600x450 2 2 (5*)
STK 8.20+ZS1 151800x1200x600 2 8 (2*)
NL8.20+ZS2 151800x1400x600 2 14 (2*)
NL8.21 151800x800x600 2 2 (5*)
NL8.21 91800x800x600 2 6 (5*)
STK8.21-2G (4*)
HVW20-E30 (3*)
9
9
1800x800x600
896x496x170
2
1
2 (5*)
HVW20 91000x600x250 1
Substations number
The Central battery system type CBC is constructed in accordance with the requirements of the standards VDE 0108 and PN-EN 50171. The structure is based on a 19 inch linear terminals in which the linear modules are installed. Linear circuits are connected to a three-row screw connector mounted on a DIN rail. The CBC System allows to monitor the particular circuits and housing through the address modules, also has a possibility of monitoring circuits (freely programmable current error at the periphery).The biggest advantage of this system is the ability to use TWIN technology that allows for installation on a single housing fittings with different strengths and of the various modes of operation. Depending on the type of the object it is possible to connect substations, allowing central battery system diversification and thereby cause a reduction in the cost of installation by shortening circuit units installed. The circuits can be freely programmed on suitable mode: clear (DS), dark (BS) and switched over. Switchable is achieved by applying the respective modules:LSM, MP500, MP4A. Sensors power outages application in the lighting switching stations allows to program the selective lighting to switch on.
central battery systemtype: CBC
Technical specification
Voltage
Charger
Output voltage
Ambient temperature
The integrity of enclosure
Safety class
Type of cabinet
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
Typ D - tree-phase power 400V 50 Hz
230 AC / 216V DC
0C - 40C
IP 21
I
STK, NL
RAL 7035
Casing type Cabinet type Battery part dimensionsL x W x D (mm)
Cabinet dimensionsL x W x D (mm)
Max modules numberNLE 4/220
Max circus number
STK 8.21-1-T5 Combi 1800x800x600/4501800x800x600/450 5 20
SKT 8.21-1 Combi 1800x800x600/4501800x800x600/450 11 44
SKT 9.21-1-T5 Combi 2000x900x600/4502000x900x600/450 5 20
SKT 9.21-1 Combi 2000x900x600/4502000x900x600/450 11 44
NL 8.21-1 Standard 1800x800x600/450 11 44
NL 8.21-2 Standard 1800x800x600/450 22 88
NL 8.21-3 (*) Standard 1800x800x600/450 33 132
* Standard cabinets shown above. Special projects on demand at extra charge.
-
p. 57 p. 58
central battery systemtype: CBN
The Central battery system type CBN is constructed in accordance with the requirements of the standards VDE 0108and PN-EN 50171. The CBN System offers various possibilities of the inclusion of safety lighting concept to buildinglighting and direct plug in of normal lighting, lack of any restrictions in planning a replacement network and plenty ofthe options.
The system features:5 work modes, different modes on a single circuit,monitoring of individual fittings,zoning possibility,visualization possibility, monitoring via Ethernet,programming of a single fitting possibility,expandability of the system of substations.
Technical specification
Voltage
Charger
Output circut number
Output voltage
Ambient temperature
The integrity of enclosure
Safety class
Type of cabinet
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
Typ D - tree-phase power 400V 50 Hz
Up to 40
230 AC / 216V DC
0C - 40C
IP 21
I
STK, NL
RAL 7035
* Standard cabinets shown above. Special projects on demand at extra charge.
Casing type SKM numberCabinet dimensionsL x W x D (mm)
IOM number
STK 8.20 101800x600x450 2 2 (5*)
STK 8.20+ZS1 151800x1200x600 2 8 (2*)
NL8.20+ZS2 151800x1400x600 2 14 (2*)
NL8.21 151800x800x600 2 2 (5*)
NL8.21 91800x800x600 2 6 (5*)
STK8.21-2G (4*)
HVW20-E30 (3*)
9
9
1800x800x600
896x496x170
2
1
2 (5*)
HVW20 91000x600x250 1
Substations number
The Central battery system type CBC is constructed in accordance with the requirements of the standards VDE 0108 and PN-EN 50171. The structure is based on a 19 inch linear terminals in which the linear modules are installed. Linear circuits are connected to a three-row screw connector mounted on a DIN rail. The CBC System allows to monitor the particular circuits and housing through the address modules, also has a possibility of monitoring circuits (freely programmable current error at the periphery).The biggest advantage of this system is the ability to use TWIN technology that allows for installation on a single housing fittings with different strengths and of the various modes of operation. Depending on the type of the object it is possible to connect substations, allowing central battery system diversification and thereby cause a reduction in the cost of installation by shortening circuit units installed. The circuits can be freely programmed on suitable mode: clear (DS), dark (BS) and switched over. Switchable is achieved by applying the respective modules:LSM, MP500, MP4A. Sensors power outages application in the lighting switching stations allows to program the selective lighting to switch on.
central battery systemtype: CBC
Technical specification
Voltage
Charger
Output voltage
Ambient temperature
The integrity of enclosure
Safety class
Type of cabinet
Colour
230V/400V 50Hz
Typ E - single-phase power 230V 50Hz
Typ D - tree-phase power 400V 50 Hz
230 AC / 216V DC
0C - 40C
IP 21
I
STK, NL
RAL 7035
Casing type Cabinet type Battery part dimensionsL x W x D (mm)
Cabinet dimensionsL x W x D (mm)
Max modules numberNLE 4/220
Max circus number
STK 8.21-1-T5 Combi 1800x800x600/4501800x800x600/450 5 20
SKT 8.21-1 Combi 1800x800x600/4501800x800x600/450 11 44
SKT 9.21-1-T5 Combi 2000x900x600/4502000x900x600/450 5 20
SKT 9.21-1 Combi 2000x900x600/4502000x900x600/450 11 44
NL 8.21-1 Standard 1800x800x600/450 11 44
NL 8.21-2 Standard 1800x800x600/450 22 88
NL 8.21-3 (*) Standard 1800x800x600/450 33 132
* Standard cabinets shown above. Special projects on demand at extra charge.
-
L1 L2
first fitting last fitting
switch on/off the
emergency mode lock (normally closed)
General connection diagram
p. 59 p. 60
-
L1 L2
first fitting last fitting
switch on/off the
emergency mode lock (normally closed)
General connection diagram
p. 59 p. 60
-
mountingaccessories
2500mAh
4000mAh
15000mAh
2500mAh
2500mAh
133x159x26x22x18x4
175x201x26x22x18x4
218x243x26x22x18x4
153x179x30x26x20x4
200x227x30x26x20x4
249x279x30x26x20x4
184x208x36x33x25x4
245x270x36x33x25x4
303x327x36x33x25x4
152x179x18x15x14x4
201x226x18x15x14x4
250x275x18x15x14x4
133x159x26x22x18x4
175x201x26x22x18x4
218x243x26x22x18x4
153x179x30x26x20x4
200x227x30x26x20x4
250x275x30x26x20x4
0,150
0,190
0,235
0,230
0,300
0,360
0,375
0,480
0,585
0,100
0,125
0,150
0,180
0,230
0,280
0,270
0,345
0,425
Wall mounting bracketfor HELIOS
Ceiling mounting bracketwith pipe for HELIOS
Polycarbonate distancefor Lovato n
Ceiling mounting bracketwith pipe for HELIOS
Under plastering clips forTIGER, TIGER DS, TIGER P
Polycarbonate bodyfor Lovato p and Led Eye
Wire rope suspension forTWINS, QUADRO, etc.
p. 61 p. 62
-
mountingaccessories
2500mAh
4000mAh
15000mAh
2500mAh
2500mAh
133x159x26x22x18x4
175x201x26x22x18x4
218x243x26x22x18x4
153x179x30x26x20x4
200x227x30x26x20x4
249x279x30x26x20x4
184x208x36x33x25x4
245x270x36x33x25x4
303x327x36x33x25x4
152x179x18x15x14x4
201x226x18x15x14x4
250x275x18x15x14x4
133x159x26x22x18x4
175x201x26x22x18x4
218x243x26x22x18x4
153x179x30x26x20x4
200x227x30x26x20x4
250x275x30x26x20x4
0,150
0,190
0,235
0,230
0,300
0,360
0,375
0,480
0,585
0,100
0,125
0,150
0,180
0,230
0,280
0,270
0,345
0,425
Wall mounting bracketfor HELIOS
Ceiling mounting bracketwith pipe for HELIOS
Polycarbonate distancefor Lovato n
Ceiling mounting bracketwith pipe for HELIOS
Under plastering clips forTIGER, TIGER DS, TIGER P
Polycarbonate bodyfor Lovato p and Led Eye
Wire rope suspension forTWINS, QUADRO, etc.
p. 61 p. 62
-
notesmodules selection table to light source
light source / cap
conversionkit
LiderL/36, LE/36*
LiderL/58, LE/58*
LiderLE/80*
power [W]duration
1/2/3
T8/G13 TC-SEL/2G7 TC-L/2G11 TC-DEL/G24q T5/G5 TC-2D/GR10q
TC-TEL/GX24q
18 30 36 58 5 7 9 11 18 24 36 40 55 10 13 18 26 6 8 13 14 21 24 28 35 39 49 54 80 16 28 38 13 18 26 32 42
information for reader
The pictures and the parameters of the products contained in this catalogue shall be considered only a commercial information and are not an offer within the meaning of the law. Some parameters of the delivered may differ from the parameters of the products in this catalogue. Appearance of some products may differ slightly from pictures and drawings represented in this catalogue. PPHU Awex reserves the right to withdraw products from catalogue or change their parameters.
p. 63 p. 64
-
notesmodules selection table to light source
light source / cap
conversionkit
LiderL/36, LE/36*
LiderL/58, LE/58*
LiderLE/80*
power [W]duration
1/2/3
T8/G13 TC-SEL/2G7 TC-L/2G11 TC-DEL/G24q T5/G5 TC-2D/GR10q
TC-TEL/GX24q
18 30 36 58 5 7 9 11 18 24 36 40 55 10 13 18 26 6 8 13 14 21 24 28 35 39 49 54 80 16 28 38 13 18 26 32 42
information for reader
The pictures and the parameters of the products contained in this catalogue shall be considered only a commercial information and are not an offer within the meaning of the law. Some parameters of the delivered may differ from the parameters of the products in this catalogue. Appearance of some products may differ slightly from pictures and drawings represented in this catalogue. PPHU Awex reserves the right to withdraw products from catalogue or change their parameters.