av00 - rhode island
Post on 21-Oct-2021
3 Views
Preview:
TRANSCRIPT
PROGRAM SPEAKERS:
SCREENS:
LCD DISPLAYS:
LCD MOUNT:
LCD BLOCKING AND BACK BOX:
PROGRAM SPEAKERS ENCLOSURES:
PROGRAM SPEAKERS CUT OUTS:
PROGRAM SPEAKERS GRILLE FABRIC:
VIDEO WALL OPENING/STRUCTURE
VIDEO WALL BLOCKING
IN-WALL CAMERA MOUNT:
MICROPHONES:
FLOOR BOX TERMINATED (LOW VOLTAGE):
AV DEVICE CUT OUTS:
AV LOW VOLTAGE CABLES:
POWER:
AV ELECTRICAL OUTLETS & CONNECTORS:
MOTOR LVC CABLE:
MOTOR LVC CABLE TERMINATED:
MOTOR LVC PROGRAMMED:
ISDN DISTRIBUTION FOR VIDEO TELECONFERNCING:
POTS 600 OHM ANALOG TELEPHONE DISTRIBUTION:
STORAGE CUPBOARD:
TELECOMMUNICATION CABLES:
ISDN PROTOCOL:
TELECOMMUNICATION CONNECTORS TERMINATED:
PBX TELEPHONE/VOICE SYSTEMS:
PBX TELEPHONE DISTRIBUTION:
NETWORK SERVICES:
TELECOMMUNICATION PLATES:
HIGH SPEED DATALINKS:
PLATES:
COAX RF PLATES:
COAX RF CABLE:
CABLES:
CONNECTORS:
COAX RF DISTRIBUTION AMPLIFIERS:
COAX RF ISOLATION TAPS AND TERMINATORS:
REPEATERS & HUBS FOR DISTRIBUTION:
LECTERN:
CUSTOM TEACHER / STUDENT STATIONS
INTERFACE:
FLOOR BOX:
AV ELECTRICAL CONDUITS & PULL STRINGS:
MICROPHONES TERMINATED:
FLOOR BOXES OR POKE THROUGH DEVICES:
FLOOR BOX DIVIDERS:
FLOOR BOX AC OUTLETS AND TELE/DATA PLATES:
AV CONNECTORS:
DIMMING EQUIPMENT:
MOTOR LVC:
AV INTERCONNECT WALL PLATES:
DIMMING LVC FOR AV INTERFACE:
DIMMING LVC PROGRAMMED:
FLOOR CONCRETE POUR BOX OR FLOOR CORES:
PROJECTION SCREENS:
PROJECTION SCREENS LVC & SWITCH:
CAMERA MOUNT:
CAMERA HARDPOINTS:
MICROPHONE TERMINATED:
MICROPHONES:
LIGHT RIGGING:
PLASMA/LCD MONITORS:
SPEAKER RIGGING:
VIDEO PROJECTOR MOUNTS:
PLASMA/LCD MONITOR ENCLOSURE:
PLASMA/LCD MONITOR CEILING MOUNTS:
SPEAKER HARDWARE & BACKBOX:
VIDEO PROJECTOR HARD POINTS:
LIGHTING SCENES AND ZONE LEVELS CONFIGURED:
MICROPHONE TABLE HOLE CUTOUTS:
ALL TEL/DATA CABLING AND RELATED TELECOMMUNICATIONS WORK BY EC / IT PROVIDER
DATE:
AV DRAWING INDEX AND RESPONSIBILITY SCHEDULE
BACK BOX, CONDUIT, AND PULL STRINGS:
BACK BOX, CONDUIT, AND PULL STRINGS:
BACK BOX, CONDUIT, AND PULL STRINGS:
AV DETAILS
AV-A
AUDIO VISUAL AND RELATED WORK BY OTHERS - RESPONSIBILITY SCHEDULE
G.C. E.C. A.V.C. CLIENT OTHER G.C. E.C. A.V.C. CLIENT NA
SUPPLIED BY INSTALLED BY
CEILING MOUNTED EQUIPMENT
WALL MOUNTED EQUIPMENT
TABLE / LECTERN MOUNTED DEVICES
ELECTRICAL (FOR AV REQUIREMENTS)
LIGHTING DIMMING SYSTEMS
MOTORIZED DRAPES / SHADES
PERMANENT FURNISHINGS
VOICE NETWORK
DATA NETWORK
BROADBAND VIDEO
CUTOUTS, GROMMETS, PEDESTAL ACCESS PANELS, CABLE MANAGEMENT SYSTEM AND
OTHER TABLE ACCESSORIES TO BE PROVIDED AND INSTALLED BY FURNITURE MANUF.
TABLE MICROPHONE HOLES BY TABLE MANUFACTURER
ALL LIGHTING / DIMMER SYSTEMS TO BE SPECIFIED BY LIGHTING CONSULTANT.
AV EQUIPMENT CREDENZA'S WITH PROPER VENTILATION CUT OUTS AND CABLE ACCESS
CUT OUTS TO BE PROVIDED AND INSTALLED BY FURNITURE MANUF.
NOTES
GENERAL:
1. AV DRAWINGS ARE TO BE CLEARLY COORDINATED
WITH ARCHITECTURAL, ELECTRICAL, AND LIGHING
PLANS.
2. GENERAL CONTRACTOR AND ELECTRICAL
CONTRACTOR SHOULD REVIEW THE AV
RESPONSIBILITY SCHEDULE THOROUGHLY.
OTHER
G.C. E.C. A.V.C. CLIENT OTHER G.C. E.C. A.V.C. CLIENT NAOTHER
NOTES
AVC TO PROVIDE MICROPHONE SAMPLE TO TABLE MANUFACTURER FOR HOLE SIZING
AV FLOOR PLANS, REFLECTED CEILING PLANS AND CONDUIT RISERS
AV SYSTEM FLOWS
ARCHITECTURAL DETAILS
AV DRAWING INDEX
L.V.C
L.V.C.
NA
NA L.V.C.
L.V.C
AV00
AV01
AV02
AV03
AV04
AV05
AV06
AV07
AV08
AV09
AV10
AV GENERAL NOTES AND LEGEND
SEMINAR/LECTURE ROOM 100A - FLOOR PLAN & RCP
ACTIVE LEARNING CLASSROOM 100C - FLOOR PLAN & RCP
EDITING SUITE ROOM 101 - FLOOR PLAN & CONDUIT RISER
RECORDING/TUTORING ROOM 104 - PLAN & CONDUIT RISER
SPEAKING/WRITING LAB ROOM 106 - FLOOR PLAN & CONDUIT RISER
SCREENING/LECTURE ROOM 103 - FLOOR PLAN & RCP
SCREENING/LECTURE ROOM 103 - ELEVATIONS & CONDUIT RISER
COLLABORATE / EDIT SUITES 108 & 110 - FLOOR PLAN & CONDUIT RISER
READING ROOM 112 - FLOOR PLAN RCP ELEVATION CONDUIT RISER
AV11 ENTRANCE VIDEO WALL PLAN AND ELEVATION
AV00.1
1ST FLOOR OVERALL PLAN
AV DETAILS
AV-B
READING ROOM + ENTRANCE VIDEO WALL CONDUIT RISER
AV03.1
AV12
AV-CAV DETAILS
SEMINAR 100A AND ACTIVE LEARNING 100C CONDUIT RISER
AV
B
ID
S
ET
SEMINAR ROOM 100A AV SIGNAL FLOWAV100
ACTIVE LEARNING CLASSROOM 100C AV SIGNAL FLOWAV101
ROOM 100A/100C CONTROL FLOWAV101.1
EDITING SUITE 101 AV SIGNAL FLOWAV102
SCREENING ROOM 103 AV SIGNAL FLOW #1 (TEACHING STATION)AV103
SCREENING ROOM 103 AV SIGNAL FLOW #2 (AV RACK)AV103.1
SCREENING ROOM 103 CONTROL FLOWAV103.2
RECORDING/TUTORING ROOM 104 AV SIGNAL FLOWAV104
SPEAKING/WRITING LAB 106 AV SIGNAL FLOWAV105
COLLABORATE/EDIT 1 ROOM 108 AV SIGNAL FLOWAV106
COLLABORATE/EDIT 2 ROOM 110 AV SIGNAL FLOWAV107
LIVING ROOM 112 SIGNAL FLOWAV108
ENTRANCE DIGITAL SIGNAGEAV109
AV-DAV DETAILS
THIS INCLUDES CHIEF PAC501 MOUNTS SPECIFIED FOR ROOM 100C AND 112
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
AV RESPONSIBILITIESSCHEDULE AND
GENERAL NOTES
AV00
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
CATV
IPTV
POTS
1
S
M
CABLE TYPES
CODE: CABLE FUNCTION: TYPE: MANF. & CAT. #: O.D.: AREA:
3G-SDI 3G-SDI CABLE (PLENUM) RG-11/U BELDEN 7731A 0.400 0.1257
A/M AUDIO/MICROPHONE (PLENUM) 2COND/20AWG/SH/PL WESTPENN 25292B 0.138 0.0150
AXLINK AXLINK (PLENUM) 2C 22AWG SH/2C 18AWG/PL BELDEN 1502P 0.205 0.0330
CAT CAT-5e (PLENUM) 4TW. PR. /24AWG/SH/PL BELDEN 1533P 0.190 0.0284
CAT-6 CAT-6a (PLENUM) 4TW. PR. /23AWG/PL BELDEN 3613 0.237 0.0441
CATV CABLE TO (PLENUM) DROP RG-6U CATV PLENUM BELDEN 9116P 0.235 0.0434
CRESNET CRESNET (PLENUM) 2C 22AWG SH/2C 18AWG/PL BELDEN 1502P 0.205 0.0330
C REMOTE CONTROL DATA BUS (PLENUM) 2TW.PR./18GA/SH/PL WESTPENN 25440B 0.253 0.0503
DISPLAYPORT PLENUM HDMI WITH DISPLAYPORT ADAPTER 15C/24AWG/SH/PL ATLONA ATP-14029 0.354 0.0984
DM-8G DIGITALMEDIA 8G CABLE (PLENUM) 4TW.PR.24GA/SH/PL CRESTRON DM-CBL-8G-P 0.244 0.0468
DM-CAT DIGITALMEDIA CABLE (PLENUM) 4TW.PR/1TW.PR./4TW.PR/SH/PL CRESTRON DM-CBL-P 0.580 0.2642
DTP DIGITAL AND SKEW-FREE CABLE (PLENUM) 8COND/26AWG/SH/PL EXTRON 22-215-03 0.235 0.0434
DVI DVI VIDEO CABLE (PLENUM) 15C/24AWG/SH/PL ATLONA ATP-14009 0.354 0.0984
FIBER DUPLEX MULTIMODE FIBER CABLE (PLENUM) (2) 62.5 MICRON CORNING 002K88-31130-A3 0.480 0.1810
FIBER-50UM DUPLEX MULTIMODE FIBER CABLE (PLENUM) (2) 50 MICRON CORNING 002T88-31191-A3 0.480 0.1810
FO-SM DUPLEX SINGLEMODE FIBER CABLE (PLENUM) (2) 8.2 MICRON CORNING 002E88-31131-A3 0.510 0.2043
HD-SDI HD-SDI CABLE (PLENUM) RG-11/U BELDEN 7731A 0.400 0.1257
HDMI HDMI A/V CABLE (PLENUM) 15C/24AWG/SH/PL ATLONA ATP-14029 0.354 0.0984
MIC MICROPHONE CABLE (PLENUM) 2COND/20AWG/SH/PL WESTPENN 25292B 0.138 0.0150
MUTE MICROPHONE MUTE CONTROL (PLENUM) 4COND/22AWG/SH/PL BELDEN 6502FC 0.133 0.0139
P CABLE FOR POWER (PLENUM) 2 COND/18GA/PL WESTPENN 25224B 0.150 0.0177
RG-8 PLENUM COAX RG-8/U CATV PLENUM BELDEN 7733A 0.355 0.0990
RG-11 CATV BACKBONE PLENUM RG-11 CATV PLENUM BELDEN 1523AP 0.260 0.0531
R RED/GREEN/BLUE/H-SYNC/V-SYNC (PLENUM) 5-RG-59U/PL EXTRON 22-103-02 0.304 0.0726
SC 70V CEILING SPEAKERS (PLENUM) 2 COND/18GA/PL WESTPENN 25224B 0.150 0.0177
SDI SDI CABLE (PLENUM) RG-11/U BELDEN 7731A 0.400 0.1257
SF SKEW FREE UTP (PLENUM) 4TW. PR. 23 AWG EXTRON 22-142-03 0.240 0.0452
S PROGRAM 8 OHM SPEAKERS (PLENUM) 2 COND/14GA/PL WESTPENN 25226B 0.260 0.0531
UHF WIRELESS MIC ANTENNA (PLENUM) 50Ω RG-58U/PL BELDEN 88240 0.160 0.0201
V DIGITAL VIDEO CABLE (PLENUM) 75Ω PREC. VID/PL BELDEN 1506A 0.200 0.0314
YC S-VIDEO (PLENUM) (2) 75Ω COAX 26 GA/PL EXTRON 22-129-03 0.250 0.0491
1
1
WP
GENERAL:
1. AV DRAWINGS, COMMUNICATIONS DRAWINGS, POWER PLAN DRAWINGS AND ARCHITECTURAL DRAWINGS SHOULD BE CAREFULLY REVIEWED
SIMULTANEOUSLY TO AVOID UNDER-COUNTING OR OVER-COUNTING DEVICES.
2. QUANTITIES GIVEN ON AV DETAIL PAGES AND AV ROOM DRAWINGS MUST BE CONFIRMED BY EACH DISCIPLINE WHEN REVIEWING THE AV DRAWINGS. THE
QUANTITIES GIVEN ARE PRELIMINARY AND MAY NOT REFLECT ALL LAST MINUTE CHANGES. ANY DISCREPANCIES SHOULD BE REVIEWED WITH THE OWNER
.
3. ALL SPARE/FUTURE CONDUITS ARE TO HAVE PULL STRINGS. ENSURE PULL STRINGS ARE TIED OFF AT BOTH ENDS OF THE CONDUIT RUN.
4. FINAL LOCATION AND COORDINATION OF ALL FLOOR BOXES TO BE VERIFIED IN FIELD WITH ARCHITECT PRIOR TO INSTALLATION.
5. ALL TELE/DATA, NETWORK, AND 120V AC SERVICES INDICATED ON AV DRAWINGS ARE FOR AV USE ONLY. FOR ALL OTHER REQUIREMENTS REFER TO
COMMUNICATIONS AND POWER PLANS.
6. CEILING MOUNTED PROJECTORS NEED TO BE ISOLATED FROM BUILDING STRUCTURES OR MECHANICAL DEVICES THAT MAY INDUCE VIBRATION TO VIDEO
PROJECTORS.
ACOUSTICAL:
1. AN OVERALL DESIGN GOAL FOR AN NC-25 TO NC-30 NOISE CRITERIA RATING IS DESIRABLE.
2. AMBIENT NOISE FROM ALL IN-ROOM AND EXTERNAL NOISE SOURCES NOT TO EXCEED 40dB A-WEIGHTED.
3. TO PREVENT SOUND LEAKAGE INTO THESE ROOMS FROM ADJOINING SPACES, ALL WALLS SHOULD EXTEND TO THE DECKING ABOVE. ALL PENETRATIONS
LEAVING THE SPACE SHOULD BE SEALED AS REQUIRED. THE SPACE ABOVE THE CEILING TILES MAY ALSO NEED CONSIDERATION AND TREATING WITH
FIBERGLASS BATTING.
4. MINIMUM SOUND TRANSMISSION CLASS FOR WALL CONSTRUCTION TO BE OF AN STC-45 RATING. DOORS INTO THE SPACE TO HAVE A MINIMUM RATING OF
STC-40 TO STC-55. WALL PARTITIONS (WHERE APPLICABLE) TO HAVE A MINIMUM RATING OF STC-55 TO STC-65.
5. ACOUSTICAL REFLECTIONS OFF ALL GLASS SURFACES SHOULD BE ADDRESSED WITH APPROPRIATE WINDOW TREATMENTS.
6. MAXIMUM REVERBERATION TIME SHOULD NOT EXCEED .6 SECONDS.
7. MECHANICAL DEVICES SUCH AS HEAT EXCHANGERS AND VENTILATION UNITS SHOULD NOT BE LOCATED IN THE CEILING ABOVE THE IMMEDIATE SPACE OR
THE SURROUNDING AREAS.
8. AIR VELOCITY AT SUPPLY REGISTER NOT TO EXCEED 425 FEET PER MINUTE. AIR VELOCITY AT RETURN GRILLE NOT TO EXCEED 510 FEET PER MINUTE.
FURNISHINGS:
1. ALL TABLES AND CREDENZAS TO BE PROVIDED WITH INTEGRATED POWER AND CABLE MANAGEMENT.
2. CHOOSE FURNITURE WITHOUT GLOSSY TOPS OR STRONG COLORS. THE BEST TABLE TOP SURFACE IS A FLAT SATIN FINISH.
3. COORDINATE ALL FLOOR BOX OR FLOOR CORING LOCATION WITH TABLE MANUFACTURER AND ARCHITECT.
4. EQUIPMENT RACKS IN A CREDENZA NEED A MINIMUM DEPTH OF 26"
5. EQUIPMENT RACKS IN A CREDENZA NEED A MINIMUM OF 40" OF ROOM FOR TWO SIDE BY SIDE RACKS IN ONE COMPARTMENT WITH A CUT OUT TO THE
NEXT COMPARTMENT FOR CABLE MANAGEMENT TO A THIRD RACK, IF NECESSARY.
6. CREDENZA EQUIPMENT RACKS WILL REQUIRE VENTILATION FROM THE FRONT TOE KICK TO THE REAR TOP BACK.
LIGHTING:
1. LIGHTING FIXTURES TO BE SELECTED WITH ELECTRONIC DIMMING BALLASTS AND TO BE CIRCUITED IN ZONES THAT ALLOW FOR ANY DISPLAYS TO BE
PROTECTED FROM AMBIENT LIGHT WHEN DESIRABLE.
2. LIGHTING FIXTURES SHOULD BE SELECTED FOR CONTROL AND DIRECTIONALITY, ALLOWING THE TABLE TO BE PROPERLY AND EVENLY LIT, WITHOUT
AFFECTING THE DISPLAY'S CONTRAST LEVELS. 85% DIFFUSED, 15% DIRECTIONAL.
3. RS-232 LIGHTING INTERFACE TO BE PROVIDED BY OTHERS TO ALLOW THE AV CONTROL SYSTEM TO SELECT LIGHTING PRESET SCENES.
4. ON/OFF ENTRY MODULES SHOULD BE PROVIDED AT DOORWAY ENTRANCES.
5. PENDANT LIGHTING SHOULD BE AVOIDED AS IT MAY CONFLICT WITH THE IMAGE CONE OF THE CEILING MOUNTED PROJECTOR (WHERE APPLICABLE).
6. DRAPES/SHADES TO BE PROVIDED WITH RS-232 INTERFACE FOR CONTROL FROM AV SYSTEM. LIMITS FOR DRAPES/SHADES TO BE SET BY OTHERS.
ELECTRICAL:
1. ALL AUDIO AND VIDEO AC OUTLETS SHOULD HAVE ITS OWN DEDICATED PHASE, NEUTRAL AND ISOLATED GROUND CONDUCTORS HOME RUN TO THE
PANEL FROM WHICH IT IS FED.
2. 120V AC SERVICES FOR EQUIPMENT RACKS AND VIDEO PROJECTORS TO SHARE THE SAME PHASE.
3. COORDINATE FINAL LOCATIONS OF SWITCHES, AV-PLATES AND J-BOXES WITH WALL TREATMENT AND SURFACES.
GENERAL:
1. THESE NOTES APPLY TO ALL SPACES WITH VIDEO-CONFERENCING CAPABILITIES DAY ONE AND THOSE WITH FUTURE VIDEO-CONFERENCING CAPABILITIES.
FURNISHINGS:
1. TABLES IN MEDIUM TO LARGE VIDEO-CONFERENCING SPACES SHOULD ACCOMMODATE AN OPEN VIEW OF ALL PARTICIPANTS WITHOUT NEEDING TO LEAN
OVER THE TABLE. TRIANGLE OR TRAPEZOIDAL SHAPES ARE IDEAL.
2. WHITE OR VERY LIGHT FURNITURE WILL REFLECT TOO MUCH LIGHT UPWARD INTO PEOPLES FACES. HIGHLY REFLECTIVE FURNITURE WILL REFLECT
GLARE FROM THE CEILING FIXTURES INTO PEOPLES FACES. FOR BEST RESULT USE FURNITURE WITH MEDIUM TONES, GRAY TAN OR WOOD TABLES WORK
WELL WITH A MATTE FINISH.
3. CHAIRS SHOULD NOT ROCK OR ROLL, TO AVOID DISTRACTIONS DURING A VIDEO-CONFERENCE.
4. WALL COLOR WITHIN THE FIELD OF VIEW OF THE CAMERA HAS A SIGNIFICANT IMPACT ON FAR-END PERCEPTION OF VIDEO QUALITY. LIGHT GRAY TO BLUE
COLORS WORK BEST. AVOID LARGE EXPANSES OF WHITE. THIS ALSO APPLIES TO ANY DRAPES/SHADES IN THE CAMERAS VIEW
4.1. RECOMMENDED COLORS: LILAC, GRAY, BLUE/GRAY, LIGHT BLUE, LIGHT BLUE/LILAC
LIGHTING:
1. LIGHTING SHOULD MEASURE 35-40 FOOT CANDLES AT A 4 FOOT VERTICAL PLANE AT THE TABLE WITH A COLOR TEMPERATURE OF 3500 KELVIN.
2. MAIN LIGHTS OR "KEY" LIGHTING SHOULD BE CAST AT ABOUT A 45° ANGLE TO THE PARTICIPANTS, RESULTING IN SHADOWS THAT DEFINE FACIAL
FEATURES.
3. LIGHTING IN THESE SPACES SHOULD HAVE A HIGHER LEVEL OF CONTROL TO MAXIMIZE THE LIGHTING SCENES FOR VIDEO- CONFERENCING.
4. BACKGROUND LIGHTING SHOULD BE UNIFORM AND AVOID DARK SPOTS AND BRIGHT AREAS TO AVOID LIGHT DISTORTION ON PEOPLES FACES. WALL
WASHER LUMINARIES ARE RECOMMENDED FOR BACK AND SIDE WALLS.
5. STANDARD FLUORESCENT FIXTURES, WALL SCONCES AND OTHER BRIGHT LIGHT SOURCES THROW A GREAT DEAL OF GLARE AT THE CAMERA, CAUSING
THE CEILING TO REGISTER AS A BIG WHITE SPOT.
6. WINDOWS SHOULD ALWAYS BE SHADED DURING VIDEO-CONFERENCE, PREFERABLY WITH BLACKOUT SHADES TO AVOID PROBLEMS WITH ROOM LIGHTING
RATIOS.
AV FLOOR PLAN SYMBOLS
SYMBOLS DESCTIPTION
WALL MOUNTED AC
DUPLEX OUTLET
WALL MOUNTED AC
QUAD DUPLEX OUTLET
WALL MOUNTED CATV DROP
WALL MOUNTED IPTV DROP
WALL MOUNTED POTS DROP
WALL MOUNTED LAN DROP
TABLE MICROPHONE
GENERIC TABLE BOX
WALL MOUNTED JUNCTION
BOX
WALL MOUNTED EQUIPMENT RACK
JUNCTION BOX OR AV PLATE
FLUSH MOUNTED FLOOR BOX
FLUSH MOUNTED FLOORCORE
SYMBOLS DESCTIPTION
CEILING MOUNTED
SPEAKER
GENERIC PROJECTOR
SYMBOL
GENERIC PROJECTION
SCREEN SYMBOL
CEILING MOUNTED
JUNCTION BOX
CEILING MOUNTED POWER
CEILING MOUNTED LAN
DROP
CEILING MOUNTED
MICROPHONE
CEILING MOUNTED JUNCTION
BOX WITH POWER/LAN
AV LEGEND
CABLE LEGEND
STANDARD ABBREVIATIONSGENERAL NOTES
VIDEO CONFERENCING NOTES
AV REFLECTED CEILING PLAN
SYMBOLS
AV CONDUIT RISER SYMBOLS
AV
ABF
AFC
AFF
ASC
ACFL
AP
ACT
ADD
ALT
AC
ANSI
APX
AUTO
BEL
BS
BOT
BTU
CB
CLG
CM
COL
CATV
C
CONF
CONST
CONT
CONTR
D
dB
DP
DTL
DIAG
DIAM
AV INTERFACE
ABOVE
ABOVE FINISH CEILING
ABOVE FINISH FLOOR
ABOVE SUSPENDED CEILING
ACCESS FLOOR
ACCESS PANEL
ACOUSTICAL TILE
ADDENDUM
ALTERNATE
ALTERNATING CURRENT
AMERICAN NATIONAL
STANDARD INSTITUTE
APPROXIMATE
AUTOMATIC
BELOW
BOTH SIDES
BOTTOM
BRITISH THERMAL UNITS
CEILING JUNCTION BOX
CEILING
CENTIMETER
COLUMN
COMMUNITY ANTENNA TV
CONDUIT
CONFERENCE
CONSTRUCTION
CONTINUOUS
CONTRACTOR
DATA
DECIBEL
DEPTH
DETAIL
DIAGONAL
DIAMETER
LAN
LC
LVC
M
MANUF
MAX
MECH
MWK
MIN
MISC
MD
MULL
NTSC
NR
NIC
NTS
OFE
OPG
OH
PED
POTS
PROJ
RF
REF
REM
REV
R
RM
RO
SCH
SEC
SIM
LOCAL AREA NETWORK
LIGHT CONTROL
LOW VOLTAGE CONTROL
METER (S)
MANUFACTURER
MAXIMUM
MECHANICAL
MILLWORK
MINIMUM
MISCELLANEOUS
MOUNTING DISTANCE
MULLION
NATIONAL TV SYSTEM
COMMITTEE
NOISE REDUCTION
NOT IN CONTRACT
NOT TO SCALE
OWNER FURNISHED
EQUIPMENT
OPENING
OVERHEAD
PEDESTAL
PLAIN OLD TELEPHONE
SERVICE
PROJECTOR
RADIO FREQUENCY
REFERENCE
REMOVE
REVISION
RIGHT
ROOM
ROUGH OPENING
SCHEDULE
SECTION
SIMILAR
DIM
DC
DR
DWG
ELEC
EC
EL
ENC
EQ
EQUIP
EXG
FO
FLR
FB
FC
FP
FUT
GA
GC
HVAC
HD
H
HDTV
HOR
INCL
IPTV
IR
ISDN
INT
JST
J
KO
LBL
L
DIMENSION
DIRECT CURRENT
DOOR
DRAWING
ELECTRICAL
ELECTRICAL CONTRACTOR
ELEVATION
ENCLOSURE
EQUAL
EQUIPMENT
EXISTING
FINISH OPENING
FLOOR
FLOOR BOX
FLOOR CORE
FRONT PROJECTION
FUTURE
GAGE, GAUGE
GENERAL CONTRACTOR
HEATING/COOLING
HEAVY-DUTY
HEIGHT
HIGH-DEFINITION TELEVISION
HORIZONTAL
INCLUDED
INTERNET PROTOCOL TELEVISION
INFRARED
INTEGRATED SERVICES
DIGITAL NETWORK
INTERIOR
JOIST
JUNCTION BOX
KNOCKOUT
LABEL
LEFT
SP
SPK
SPEC
STD
S-VHS
SVGA
SUS
SW
SYS
TEL/COM
TEL
TV
TD
TYP
UON
VERT
VGA
VTC
V ac
V dc
WH
W
W/O
SOUNDPROOF
SPEAKER
SPECIFICATION
STANDARD
SUPER VHS (VIDEO FORMAT)
SUPER VIDEO GRAPHIC ADAPTER
SUSPENDED
SWITCH
SYSTEM
TELECOMMUNICATIONS
TELEPHONE
TELEVISION
THROW DISTANCE
TYPICAL
UNLESS OTHERWISE NOTED
VERTICAL
VIDEO GRAPHIC ADAPTER
VIDEO TELECONFERENCING
VOLTS ALTERNATING CURRENT
VOLTS DIRECT CURRENT
WALL HUNG
WIDTH
WITHOUT
CEILING MOUNTED POWER
OUTLET - 120V AC
AC CLOCK
RECEPTACLE - 120V AC
AC DUPLEX OUTLET - 12V AC
LAN WITH QUANTITY
ANALOG LINE WITH
QUANITY
WALL PHONE
CATV
J-BOX
SYMBOLS DESCTIPTION
STUBBED CONDUIT
RIGID CONDUIT
PLENUM CABLE
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
AV GENERAL NOTESAND LEGEND
AV00.1
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
1
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
1ST FLOOR OVERALLPLAN
AV01
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 3/16" = 1'-0"
FIRST FLOOR OVERALL PLAN
1
60" x 96"
SC
RE
EN
48" LCD
4
8
"
L
C
D
48" LCD
48" L
CD
60" x 96"
SC
RE
EN
48" L
CD
48" LCD
48" LCD
90" LCD
76.25" x 122"
SC
RE
EN
48" LCD
4
8
"
L
C
D
4
8
"
L
C
D
48" L
CD
48" L
CD
48" L
CD
QUAD 46" LCD VIDEO WALL
J-5
2 GANG AV INPUT PLATE
WITH POWER AND LAN
LOCATED AT 15" AFF
AV10AV09AV06AV05
AV02
AV11
AV04 AV07
AV03
CA
TV
1
SS
S S
S
S
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SEMINAR LECTUREROOM 100A - FLOOR
PLAN & RCP
AV02
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 3/8" = 1'-0"
SEMINAR/LECTURE ROOM 100A FLOOR PLAN
1
Scale: 3/8" = 1'-0"
SEMINAR/LECTURE ROOM 100A RCP
2
AV-1A
AV INPUT PLATE WITH POWER AND LAN
OFE LECTERN
FB-1A
FLOORBOX WITH
POWER, LAN, AND AV
CONNECTIVITY
(FUTURE)
AV-2A
AV INPUT PLATE WITH
POWER AND LAN
(FUTURE)
FB-2A
FLOORBOX WITH
POWER, LAN, AND AV
CONNECTIVITY
J-1
MAIN PULL BOX WITH (2)
QUAD POWER, (4) LAN,
AND (2) CATV
D-1
AV-A
MIDDLE ATLANTIC MRK-24-26
AV EQUIPMENT RACK
D-4
AV-A
TANNOY CVS6 CEILING
SPEAKERS
TYP. 6
CB-1A
WITH POWER
AND LAN
D-2
AV-A
EPSON G6470WU 4500
LUMEN PROJECTOR
D-3
AV-A
DALITE TENSIONED
ADVANTAGE ELECTROL
60"H x 96"W CEILING
RECESSED ELECTRIC
PROJECTION SCREEN
J-2A
SCREEN SWITCH
TO J-1
13' THROW DISTANCE
FURNITURE NOTES:
1. RECONFIGURABLE FURNITURE SYSTEM WILL UTILIZE FLOOR BOXES SUPPLIED WITH
POWER/LAN BY OTHERS.
2. MOVABLE LECTERN WILL UTILIZE FLOOR BOXES SUPPLIED WITH POWER BY EC AND LAN BY
TEL/DATA.
GENERAL NOTES:
1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE
AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN
DEDICATED CIRCUITS.
2. MECHANICAL DEVICES LOCATED WITHIN CEILING SHOULD NOT BE LOCATED NEAR CEILING
PROJECTORS. THESE DEVICES COULD INDUCE VIBRATION AT THE PROJECTORS. TAKE
PRECAUTION TO LIMIT ANY VIBRATION WITHIN THE CEILING THAT COULD BE TRANSFERRED TO
THE PROJECTORS.
LIGHTING / DRAPE NOTES:
1. PENDANT LIGHT FIXTURES TO BE CAREFULLY COORDINATED SO THAT THEY DO NOT IMPEDE
DATA PROJECTORS CONE.
2. LIGHTING ZONES TO BE CIRCUITED AND DIMMABLE. FRONT ZONE OF LIGHTING CLOSEST TO
PROJECTION SCREENS SHOULD BE ON A SEPARATE ZONE SO THAT IT CAN BE DIMMED OR
SHUT OFF IF NECESSARY.
3. WINDOW TREATMENTS SHOULD BE PROVIDED WHERE AMBIENT LIGHT FROM OUTDOORS OR
OTHER LIGHT SOURCES THAT HAVE THE POTENTIAL TO AFFECT THE PROJECTED IMAGES ON
THE PROJECTION SCREENS.
ESTIMATED POWER CONSUMPTION & BTU LOAD CHART
EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)
PROJECTOR 311 1 1061 1061
EQUIPMENT RACK 1500 1 5115 5115
TOTAL BTU: 6176 6176
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
D-19
AV-D
MIDDLE ATLANTIC SRSR
RACK INSIDE LECTERN
D-17
AV-C
EXTRON CABLE CUBBY 500
1
1
CA
TV
S S
S S
S S
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012
DURKEE BROWN VIVEIROS WERENFELS ARCHITECTS
UNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of
Communication & Media
University of Rhode IslandKingston, RI
MBH
ACTIVE LEARNING
CLASSROOM 100C -
FLOOR PLAN & RCP
AV03
ACT Associates, LLC
922F Stafford Road
Storrs, CT 06268
tel. 860.429.5938
www.act-associates.com
Scale: 3/8" = 1'-0"
ACTIVE LEARNING CLASSROOM 100C FLOOR PLAN1
FB-2C
FLOORBOX WITH POWER,
LAN AND LOCAL AV
CONNECTIVITY TO MONITOR
D-5
AV-A
48" LED MONITOR ON
CHIEF CHEIF
PNRIW+PAC-501
PULL-OUT MOUNT
TYP. 3 LOCATIONS
Scale: 3/8" = 1'-0"
ACTIVE LEARNING CLASSROOM 100C FLOOR PLAN2
FB-3C
FLOORBOX WITH POWER,
LAN AND LOCAL AV
CONNECTIVITY TO
MONITOR
FB-1C
FLOORBOX WITH
POWER, LAN AND AV
CONNECTIVITY
FB-4C
FLOORBOX WITH POWER,
LAN AND LOCAL AV
CONNECTIVITY TO
MONITOR
FB-5C
FLOORBOX WITH POWER,
LAN AND LOCAL AV
CONNECTIVITY TO
MONITOR
J-5C
WITH POWER AND LAN
J-2C
WITH POWER AND LAN
J-3C
WITH POWER AND LAN
J-4C
WITH POWER AND LAN
D-5
AV-A
48" LED MONITOR ON
CHIEF CHEIF
PNRIW+PAC-501
PULL-OUT MOUNT
TYP. 3 LOCATIONS
D-6
AV-A
48" LED MONITOR ON
CHIEF MTMU MOUNT
TYP. 1 LOCATIONS
D-5
AV-A
48" LED MONITOR
RECESSED ON CHIEF
CHEIF PNRIW+PAC-501
MOUNT
TYP. 3 LOCATIONS
D-4
AV-A
TANNOY CVS6 CEILING
SPEAKERS
TYP. 6
CB-1C
WITH POWER AND LAN
D-2
AV-A
EPSON G6470 4500 LUMEN
PROJECTOR
D-3
AV-A
DALITE TENSIONED
ADVANTAGE ELECTROL
60"H x 96"W CEILING
RECESSED ELECTRIC
PROJECTION SCREEN
NOTE: TABLES WILL HAVE (8)
BUILT IN LAPTOP "GARAGES".
PROVIDE NECESSARY NETWORK
CONNECTIVITY PER URI
STANDARDS (BY OTHERS).
J-6C
SCREEN SWITCH
13' THROW DISTANCE
FURNITURE NOTES:
1. TABLE PEDESTALS SHOULD HAVE REMOVABLE ACCESS PANEL FOR SERVICE.
GENERAL NOTES:
1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE
AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN
DEDICATED CIRCUITS.
2. MECHANICAL DEVICES LOCATED WITHIN CEILING SHOULD NOT BE LOCATED NEAR CEILING
PROJECTORS. THESE DEVICES COULD INDUCE VIBRATION AT THE PROJECTORS. TAKE
PRECAUTION TO LIMIT ANY VIBRATION WITHIN THE CEILING THAT COULD BE TRANSFERRED TO
THE PROJECTORS.
3. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT
IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.
4. EACH FLOORBOX SHOULD BE ON ITS OWN DEDICATED 20A CIRCUIT.
LIGHTING / DRAPE NOTES:
1. PENDANT LIGHT FIXTURES TO BE CAREFULLY COORDINATED SO THAT THEY DO NOT IMPEDE
DATA PROJECTORS CONE.
2. LIGHTING ZONES TO BE CIRCUITED AND DIMMABLE. FRONT ZONE OF LIGHTING CLOSEST TO
PROJECTION SCREENS SHOULD BE ON A SEPARATE ZONE SO THAT IT CAN BE DIMMED OR
SHUT OFF IF NECESSARY.
3. WINDOW TREATMENTS SHOULD BE PROVIDED WHERE AMBIENT LIGHT FROM OUTDOORS OR
OTHER LIGHT SOURCES THAT HAVE THE POTENTIAL TO AFFECT THE PROJECTED IMAGES ON
THE PROJECTION SCREENS.
ESTIMATED POWER CONSUMPTION & BTU LOAD CHART
EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)
LCD MONITOR 188 4 641 2564
PROJECTOR 528 1 1800 1800
EQUIPMENT RACK 1500 1 5115 5115
TOTAL BTU: 7557 9480
J-1
MAIN PULL BOX WITH (2)
QUAD POWER, (4) LAN,
AND (2) CATV
D-1
AV-A
MIDDLE ATLANTIC
WRK-44SA-27 AV
EQUIPMENT RACK
TO J-1
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
D-17
AV-C
EXTRON CABLE CUBBY
500D-18
AV-C
EXTRON CABLE CUBBY
1400 PER TABLE
TYP. 4 TABLES
D-19
AV-D
MIDDLE ATLANTIC SRSR
EQUIPMENT RACK INSIDE
DESK
SLAB
FLOOR
CEILING
ELECTRICAL SCHEDULE
SYM. DESCRIPTION
STUBBED
CONDUIT
CEILING POWER OUTLET - 120V AC
AC CLOCK RECEPTACLE - 120V AC
AC DUPLEX OUTLET - 120V AC
AC QUAD OUTLET - 120V AC
LAN WITH QUANTITY
RIGID
CONDUIT
ANALOG LINE WITH QUANTITY
WALL PHONE
CATV
J-BOX
PLENUM
CABLE
CEILING PULL AREA
SHADE LVC
LIGHTING LVC
SCREEN LVC
LIGHT SWITCH
SCREEN SWITCH
J-
CB-
SH
LVC
LT
LVC
SCR
LVC
LT
SW
SS
SW
JUNCTION BOX SCHEDULE
BOX #: SIZE: FUNCTION: LOCATION:
ADD'L CABLE
BEYOND BOX
AFF
AV CLOSET
J-1 8x8 RACK PULL BOX SEE AV FLOOR PLAN 15'-0" 18"
SEMINAR / LECTURE 100A
J-2A 1 GANG SCREEN SWITCH SEE AV FLOOR PLAN 5'-0" 48"
AV-1A 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 18"
AV-2A 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 18"
FB-1A MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A
FB-2A MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A
CB-1A MANUF. PLENUM CEILING BOX SEE AV RCP 10'-0" AFC
ACTIVE LEARNING CLASSROOM 100C
J-2C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 66"
J-3C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 66"
J-4C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 66"
J-5C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 66"
J-6C 1 GANG SCREEN SWITCH SEE AV FLOOR PLAN 5'-0" 48"
FB-1C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A
FB-2C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A
FB-3C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A
FB-4C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A
FB-5C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A
CB-1C MANUF. PLENUM CEILING BOX SEE AV RCP 10'-0" AFC
NOTES:
1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.
2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS
3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.
4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.
5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.
6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,
FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME
PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS
7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.
8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS
9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL
DEVICES.
J-1
4
2
CB-1A
J-2A
AV-2A AV-1A
1 1
FB-2A FB-1A
2 2
FB-1C
2
FB-2C
2
CB-1C
J-6C
J-2C 1
FB-3C
2
J-3C 1
FB-4C
2
J-4C 1
FB-5C
2
J-5C 1
ACTIVE LEARNING
CLASSROOM 100C
SEMINAR/ LECTURE 100A
CEILING SPEAKERS
TYP. 6
CEILING SPEAKERS
TYP. 6
PROJECTOR PROJECTOR
SCREEN
SWITCH
SCREEN
SWITCH
(4) 1 1/4"
CONDUITS
48" LCD MONITOR 48" LCD MONITOR 48" LCD MONITOR 48" LCD MONITOR
1-1/4"
CONDUIT
1-1/4"
CONDUIT
1-1/4"
CONDUIT
1-1/4"
CONDUIT
1-1/4"
CONDUIT
1-1/4"
CONDUIT
1-1/4"
CONDUIT
1-1/4"
CONDUIT
TEACHERS STATION
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SEMINAR 100A &ACTIVE LEARNING 100C
CONDUIT RISER
AV03.1
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
22
2
2
SLAB
FLOOR
CEILING
SLAB
ELECTRICAL SCHEDULE
SYM. DESCRIPTION
STUBBED
CONDUIT
CEILING POWER OUTLET - 120V AC
AC CLOCK RECEPTACLE - 120V AC
AC DUPLEX OUTLET - 120V AC
AC QUAD OUTLET - 120V AC
LAN WITH QUANTITY
RIGID
CONDUIT
ANALOG LINE WITH QUANTITY
WALL PHONE
CATV
J-BOX
PLENUM
CABLE
CEILING PULL AREA
SHADE LVC
LIGHTING LVC
SCREEN LVC
LIGHT SWITCH
SCREEN SWITCH
J-
CB-
SH
LVC
LT
LVC
SCR
LVC
LT
SW
SS
SW
JUNCTION BOX SCHEDULE
BOX #: SIZE: FUNCTION: LOCATION:
ADD'L CABLE
BEYOND BOX
AFF
EDITING SUITE ROOM 101
J-1 2 GANG PULL AREA SEE AV FLOOR PLAN
10'-0" 15"
J-2 3 GANG MONITOR SEE AV FLOOR PLAN
4'-0" 60"
J-3 5 GANG INTERFACE PLATE SEE AV FLOOR PLAN
3'-0" 36"
J-4 3 GANG CONTROL INTERFACE SEE AV FLOOR PLAN
3'-0"
36"
NOTES:
1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.
2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS
3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.
4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.
5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.
6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,
FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME
PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS
7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.
8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS
9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL
DEVICES.
2
J-1
J-2
COUNTER
J-3
J-4
2
LCD MONITOR
2 2
CAT5
CAT5
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
EDITING SUITE ROOM101 - FLOOR PLAN &
CONDUIT RISER
AV04
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 1/2" = 1'-0"
EDITING SUITE ROOM 101 PLAN
1
2.5" THROUGH COUNTER GROMMETT
(BY OTHERS)
Scale: NTS
EDITING SUITE ROOM 101 CONDUIT RISER
3
ESTIMATED POWER CONSUMPTION & BTU LOAD CHART
EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)
LCD MONITOR 55 1 188 188
EQUIPMENT RACK 600 1 2046 2046
TOTAL BTU: 2234 2234
GENERAL NOTES:
1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE
AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN
DEDICATED CIRCUITS.
2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT
IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.
J-2
3 GANG PULL BOX FOR
MONITOR WITH AC CLOCK
RECEPTACLE
J-1
2 GANG PULL BOX FOR RACK -
POWER AND LAN TO BE
LOCATED AT RACKLOCATION IN
CORNER
J-4
BUTTON CONTROLLER
MOUNTED INTO 3 GANG
BOX
Scale: 3/4" = 1'-0"
EDITING SUITE ROOM 101 ELEVATION
2
J-2
3 GANG PULL BOX FOR
MONITOR WITH AC CLOCK
RECEPTACLE
J-1
2 GANG PULL BOX FOR RACK -
POWER AND LAN TO BE
LOCATED AT RACKLOCATION IN
CORNER
J-4
BUTTON CONTROLLER
MOUNTED INTO 3 GANG
BOX
CABLING TO RUN ALONG
UNDERSIDE OF
COUNTERTOP FROM J-1
TO RACK
15
"
36
"
15
"
D-8
AV-B
AV RACK LOCATED IN
CORNER WITH QUAD
POWER AND LAN
D-6
AV-A
SAMSNUG DM48D 48" LCD
MONITOR
D-8
AV-B
AV RACK LOCATED IN
CORNER WITH QUAD
POWER AND LAN
D-6
AV-A
SAMSUNG DM48D 48" LCD
MONITOR
D-7
AV-B
J-3
CUSTOM 5 GANG AV
INPUT PLATE
D-7
AV-B
J-3
CUSTOM 5 GANG AV
INPUT PLATE
60
"
CONVENIENCE OUTLETS - QUAD
POWER AND LAN LOCATED
BELOW COUNTER TOP
TYP. 2 LOCATIONS
FOSTEX PM0.4d PROGRAM
MONITOR SPEAKERS
*PROVIDE CABLE GROMMET
FOR SPEAKERS
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
*CONNECT POWER FOR MONITOR
SPEAKERS AT AV RACK
FURNITURE NOTES:
1. PROVIDE CUT AND GROMMET IN TOP FOR SPEAKER CABLING.
2. AV CONTRACTOR SHALL PROVIDE WIRE MANAGEMENT CHANNEL FOR CABLING BETWEEN
EQUIPMENT AT TABLE SURFACE AND PATHWAY TO AV RACK.
22
SLAB
FLOOR
CEILING
SLAB
ELECTRICAL SCHEDULE
SYM. DESCRIPTION
STUBBED
CONDUIT
CEILING POWER OUTLET - 120V AC
AC CLOCK RECEPTACLE - 120V AC
AC DUPLEX OUTLET - 120V AC
AC QUAD OUTLET - 120V AC
LAN WITH QUANTITY
RIGID
CONDUIT
ANALOG LINE WITH QUANTITY
WALL PHONE
CATV
J-BOX
PLENUM
CABLE
CEILING PULL AREA
SHADE LVC
LIGHTING LVC
SCREEN LVC
LIGHT SWITCH
SCREEN SWITCH
J-
CB-
SH
LVC
LT
LVC
SCR
LVC
LT
SW
SS
SW
JUNCTION BOX SCHEDULE
BOX #: SIZE: FUNCTION: LOCATION:
ADD'L CABLE
BEYOND BOX
AFF
RECORDING TUTORING ROOM 104
J-1 2 GANG PULL AREA SEE AV FLOOR PLAN
10'-0" 36"
J-2 3 GANG MONITOR SEE AV FLOOR PLAN
4'-0" 48"
J-3 5 GANG INTERFACE PLATE SEE AV FLOOR PLAN
3'-0" 32"
J-4 3 GANG CONTROL INTERFACE SEE AV FLOOR PLAN
3'-0" 32"
J-5 2 GANG TABLE FEED SEE AV FLOOR PLAN
6'-0" 15"
NOTES:
1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.
2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS
3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.
4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.
5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.
6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,
FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME
PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS
7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.
8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS
9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL
DEVICES.
2
J-1
J-2
TABLE
J-3
J-4
2
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
RECORDING TUTORINGROOM 104 - PLAN &
CONDUIT RISER
AV05
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 3/4" = 1'-0"
RECORDING/TUTORING 104 PLAN
1
Scale: NTS
RECORDING/TUTORING 104 CONDUIT RISER
3
J-2
3 GANG PULL BOX FOR
MONITOR WITH AC CLOCK
RECEPTACLE
J-1
2 GANG PULL BOX FOR RACK
WITH POWER AND LAN
J-4
BUTTON CONTROLLER
MOUNTED TO 1 GANG
BOX
ESTIMATED POWER CONSUMPTION & BTU LOAD CHART
EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)
LCD MONITOR 55 1 188 188
EQUIPMENT RACK 500 1 1705 1705
TOTAL BTU: 1893 1893
GENERAL NOTES:
1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE
AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN
DEDICATED CIRCUITS.
2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT
IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.
3. WALL MOUNTED EQUIPMENT RACKS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING
THAT IS RATED FOR 5 TIMES THE WEIGHT OF THE EQUIPMENT RACK
Scale: 3/4" = 1'-0"
RECORDING/TUTORING 104 ELEVATION
2
J-2
3 GANG PULL BOX FOR
MONITOR WITH 2 AC CLOCK
RECEPTACLES
J-4
BUTTON CONTROLLER
MOUNTED INTO 3 GANG
BOX
J-1
2 GANG PULL BOX FOR RACK
WITH POWER AND LAN
D-6
AV-A
SAMSUNG M48D 48" LCD
MONITOR
D-10
AV-B
CHIEF NW2 WALL
MOUNTED RACK
D-10
AV-B
CHIEF NW2 WALL
MOUNTED RACK
D-6
AV-A
SAMSUNG DM48D 48" LCD
MONITOR
D-7
AV-B
J-3
CUSTOM 5 GANG AV
INPUT PLATE
D-7
AV-B
J-3
CUSTOM 5 GANG AV
INPUT PLATE
J-5
2 GANG PLATE FOR TABLE BOX
CONNECTION BELOW TABLE
32
"
36
"
48
"
15
"
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
MACKIE HRmk2
REFERENCE MONITOR
(TYP. 2)
14
14
SLAB
FLOOR
CEILING
SLAB
ELECTRICAL SCHEDULE
SYM. DESCTIPTION
STUBBED
CONDUIT
CEILING POWER OUTLET - 120V AC
AC CLOCK RECEPTACLE - 120V AC
AC DUPLEX OUTLET - 120V AC
AC QUAD OUTLET - 120V AC
LAN WITH QUANTITY
RIGID
CONDUIT
ANALOG LINE WITH QUANITY
WALL PHONE
CATV
J-BOX
PLENUM
CABLE
CEILING PULL AREA
SHADE LVC
LIGHTING LVC
SCREEN LVC
LIGHT SWITCH
SCREEN SWITCH
J-
CB-
SH
LVC
LT
LVC
SCR
LVC
LT
SW
SS
SW
JUNCTION BOX SCHEDULE
BOX #: SIZE: FUNCTION: LOCATION:
ADD'L CABLE
BEYOND BOX
AFF
SPEAKING WRITING LAB 106
J-1A 1 GANG PULL AREA SEE AV FLOOR PLAN
10'-0" 15"
J-1B 1 GANG PULL AREA SEE AV FLOOR PLAN
10'-0" 15"
J-2A 1 GANG MONITOR SEE AV FLOOR PLAN
5'-0" 48"
J-2B 1 GANG MONITOR SEE AV FLOOR PLAN
5'-0" 48"
AV-1A MANUF. TABLE BOX SEE AV FLOOR PLAN
5'-0" N.A.
AV-1B MANUF. TABLE BOX SEE AV FLOOR PLAN
5'-0" N.A.
NOTES:
1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.
2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS
3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.
4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.
5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.
6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,
FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME
PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS
7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.
8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS
9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL
DEVICES.
4J-1A
J-2A 1 J-2B 1
4J-1B
AV-1A AV-1B
CAT5
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SPEAKING WRITINGLAB 106 - FLOOR PLAN
& CONDUIT RISER
AV06
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 3/8" = 1'-0"
SPEAKING/WRITING LAB 106 - FLOOR PLAN
1
Scale: NTS
SPEAKING/WRITING LAB 106 - CONDUIT RISER
3
Scale: 3/4" = 1'-0"
SPEAKING/WRITING LAB 106 - ELEVATION (TYP. OF 2)
2
ESTIMATED POWER CONSUMPTION & BTU LOAD CHART
EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)
LCD MONITOR 50 2 171 341
TOTAL BTU: 171 341
GENERAL NOTES:
1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE
AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN
DEDICATED CIRCUITS.
2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT
IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.
J-2B
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
J-1B
1 GANG BOX FOR AV
WITH QUAD POWER AND
(4) LAN
EXTRON CABLE CUBBY 700
TABLE BOX
J-2A
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
J-1A
1 GANG BOX FOR AV
WITH QUAD POWER AND
(4) LAN
EXTRON CABLE CUBBY 700
TABLE BOX
J-2A
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
J-1A
1 GANG BOX FOR AV
WITH QUAD POWER AND
(4) LAN
D-6
AV-A
SAMSUNG DM48D 48" LCD
MONITOR
D-6
AV-A
SAMSUNG DM48D 48" LCD
MONITOR
TYP. 2
D-6
AV-A
SAMSUNG DM48D 48" LCD
MONITOR
15
"
48
"
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
4
CATV
1
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SCREENING LECTUREROOM 103 - FLOOR
PLAN & RCP
AV07
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 3/8" = 1'-0"
SCREENING/LECTURE ROOM 103 - FLOOR PLAN
1
ESTIMATED POWER CONSUMPTION & BTU LOAD CHART
EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)
98" LCD MONITOR 420 1 1432 1432
EQUIPMENT RACK 2000 1 6820 6820
TOTAL BTU: 8252 8252
FURNITURE NOTES:
1. MOVABLE TEACHING STATION WILL UTILIZE FLOOR BOXES SUPPLIED WITH POWER BY EC AND
LAN BY TEL/DATA.
GENERAL NOTES:
1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE
AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN
DEDICATED CIRCUITS.
J-1
WITH QUAD POWER, (4)
LAN, AND CATV
FB-1
WIREMOLD CRFB POKE-THRU
DEVICE MOUNTED TO FACE OF
SEATING RISER WITH POWER, LAN,
AND AV CONNECTIVITY
FB-2
WIREMOLD CRFB POKE-THRU DEVICE
MOUNTED TO FACE OF SEATING RISER
WITH POWER, LAN, AND AV
CONNECTIVITY
D-1
AV-A
MIDDLE ATLANTIC
MRK-24-26
EQUIPMENT RACK
D-15
AV-C
J-3
FRONT RIGHT LEON VAULT
ULTIMA PROGRAM SPEAKER
TYP. 2 LOCATIONS
J-7
REAR RIGHT CHANNEL
TANNOY VX 5.2
PROGRAM SPEAKER
J-8
REAR LEFT CHANNEL
TANNOY VX 5.2
PROGRAM SPEAKER
J-6
SIDE LEFT CHANNEL
TANNOY VX 5.2
PROGRAM SPEAKER
J-5
SIDE RIGHT CHANNEL
TANNOY VX 5.2
PROGRAM SPEAKER
TYP 4 LOCATIONS
D-12
AV-B
J-9
LEON A10UT IN-WALL
SUBWOOFER
J-4
FRONT LEFT
LEON VAULT ULTIMA
PROGRAM SPEAKER
J-2
CHIEF PAC521P BACK
BOX WITH POWER
D-14
AV-C
NEC X981UHD 98" LCD
MONITOR ON CHIEF
MOUNT W/ SOUNDBAR
BELOW
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
D-17
AV-C
EXTRON CABLE CUBBY 500
AV-19
AV-D
MIDDLE ATLANTIC
SRSR RACK INSIDE OF
TEACHERS STATION
SLAB
FLOOR
CEILING
SLAB
ELECTRICAL SCHEDULE
SYM. DESCRIPTION
STUBBED
CONDUIT
CEILING POWER OUTLET - 120V AC
AC CLOCK RECEPTACLE - 120V AC
AC DUPLEX OUTLET - 120V AC
AC QUAD OUTLET - 120V AC
LAN WITH QUANTITY
RIGID
CONDUIT
ANALOG LINE WITH QUANITY
WALL PHONE
CATV
J-BOX
PLENUM
CABLE
CEILING PULL AREA
SHADE LVC
LIGHTING LVC
SCREEN LVC
LIGHT SWITCH
SCREEN SWITCH
J-
CB-
SH
LVC
LT
LVC
SCR
LVC
LT
SW
SS
SW
JUNCTION BOX SCHEDULE
BOX #: SIZE: FUNCTION: LOCATION:
ADD'L CABLE
BEYOND BOX
AFF
LECTURE ROOM SM-01
J-1 8x8 RACK PULL BOX SEE AV FLOOR PLAN 15'-0" 18"
J-2 MANUF. MONITOR BACK BOX SEE AV FLOOR PLAN 5'-0" 89"
J-3 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 103"
J-4 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 103"
J-5 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 105"
J-6 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 105"
J-7 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 87"
J-8 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 87"
J-9 MANUF. IN WALL SUBWOOFER SEE AV FLOOR PLAN 5'-0" N/A
FB-1 MANUF. FLOOR BOX FACE OF SEATING RISER 15'-0"
OF
RISER
FB-2 MANUF. FLOOR BOX FACE OF SEATING RISER 15'-0"
OF
RISER
J-1
(4) 1-1/4"
CONDUITS
4
NOTES:
1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE
SPECIFIED.
2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL
CONDUITS
3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE
NUMBERS AND CONDUIT INTERCONNECT ONLY.
4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX
LOCATION OR EXACT CONDUIT ROUTING.
5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND
ELECTRICAL PRINTS.
6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED
PROJECTORS, LCD OR PLASMA MONITORS, FLOOR BOXES WITH AV,
AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT
BE ON THE SAME PHASE AS COMPRESSORS, MOTORS OR LIGHT
DIMMING SYSTEMS.
7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS
INDICATED.
8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL
OUT LOCATIONS
9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH
ARCHITECTS PRIOR TO INSTALLATION OF ALL DEVICES.
FC-1
FLOOR
CORE
POKE-THRU
2
FB-1 FB-2
2
J-2
J-3J-4
J-5J-6J-7J-8
IN-WALL SUBWOOFER
REAR
SPEAKERS
SIDE
SPEAKERS
98" 4K LCD MONITOR
LEFT
SPEAKER
RIGHT
SPEAKER
INSTRUCTORS STATION
1
SOUNDBAR (MOUNTED BELOW TV)
J-9
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SCREENING LECTUREROOM 103 -
ELEVATIONS &CONDUIT RISER
AV08
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 3/8" = 1'-0"
SCREENING/LECTURE ROOM 103 - ELEVATION
2
Scale: 3/8" = 1'-0"
SCREENING/LECTURE ROOM 103 - SECTION
1
Scale: NTS
SCREENING/LECTURE ROOM 103 - CONDUIT RISER
3
7'-3
"
86 3/4"
49
5
/8
"
65
7
/8
"
90
3
/4
"
1 1/8"
1"
11
6 1
/2
"
10
3 1
/2
"
97
1
/8
"
D-11
AV-B
J-3
FRONT RIGHT TANNOY VS
LEON VAULT SPEAKER
PROGRAM SPEAKER
TYP. 2 LOCATIONS
J-4
FRONT LEFT CHANNEL
LEON VAULT SPEAKER
PROGRAM SPEAKER
J-2
CHIEF PAC521P BACK
BOX WITH POWER
D-14
AV-C
NEC X981UHD 98" 4K
LCD MONITOR ON
CHIEF MOUNT
57
1
/2
"
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
7"
SOUND BAR WIDTH IS
EDGE-TO-EDGE WITHIN NICHE.
VERIFY DIMENSION IN FIELD BEFORE
ORDERING
SUBWOOFER
LEON ACS10UT IN-WALL
SUBWOOFER. REMOVE STAND
BEFORE INSTALLATION
D-15
AV-C
CENTER CHANNEL
LEON HZ ULTIMA
SOUNDBAR WALL MOUNTED
UNDER MONITOR.
1
1
4
4
SLAB
FLOOR
CEILING
SLAB
ELECTRICAL SCHEDULE
SYM. DESCRIPTION
STUBBED
CONDUIT
CEILING POWER OUTLET - 120V AC
AC CLOCK RECEPTACLE - 120V AC
AC DUPLEX OUTLET - 120V AC
AC QUAD OUTLET - 120V AC
LAN WITH QUANTITY
RIGID
CONDUIT
ANALOG LINE WITH QUANTITY
WALL PHONE
CATV
J-BOX
PLENUM
CABLE
CEILING PULL AREA
SHADE LVC
LIGHTING LVC
SCREEN LVC
LIGHT SWITCH
SCREEN SWITCH
J-
CB-
SH
LVC
LT
LVC
SCR
LVC
LT
SW
SS
SW
JUNCTION BOX SCHEDULE
BOX #: SIZE: FUNCTION: LOCATION:
ADD'L CABLE
BEYOND BOX
AFF
EDITING SUITE 101
J-1A 1 GANG PULL AREA SEE AV FLOOR PLAN
10'-0" 15"
J-1B 1 GANG PULL AREA SEE AV FLOOR PLAN
10'-0" 15"
J-2A 1 GANG MONITOR SEE AV FLOOR PLAN
5'-0" 48"
J-2B 1 GANG MONITOR SEE AV FLOOR PLAN
5'-0" 48"
J-3A 5 GANG CUSTOM PLATE SEE AV FLOOR PLAN
5'-0" 32"
J-3B 5 GANG CUSTOM PLATE SEE AV FLOOR PLAN
5'-0" 32"
NOTES:
1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.
2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS
3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.
4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.
5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.
6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,
FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME
PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS
7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.
8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS
9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL
DEVICES.
J-3A
J-2A 1
J-3B
J-2B 1
4
J-1A
4
J-1B
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
COLLABORATE EDITSUITES 108 & 110 -
FLOOR PLAN &CONDUIT RISER
AV09
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 1/2" = 1'-0"
COLLABORATE EDIT SUITES 108 & 110 PLAN
1
J-2B
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
J-1B
1 GANG BOX FOR AV
WITH QUAD POWER AND
(4) LAN
EXTRON CABLE CUBBY 1400
TABLE BOX
J-2A
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
J-1A
1 GANG BOX FOR AV
WITH QUAD POWER AND
(4) LAN
EXTRON CABLE CUBBY 1400
TABLE BOX
ESTIMATED POWER CONSUMPTION & BTU LOAD CHART
EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)
LCD MONITOR 55 2 188 375
TOTAL BTU: 188 375
GENERAL NOTES:
1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE
AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN
DEDICATED CIRCUITS.
2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT
IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.
3. CARE SHOULD BE TAKEN TO OFFSET BOXES TO AVOID INTERFERING WITH OPPOSITEWALL.
Scale: NTS
COLLABORATE EDIT SUITES 108 & 110 - CONDUIT RISER
3
Scale: 3/4" = 1'-0"
COLLABORATE EDIT SUITES 108 & 110 - ELEVATION
2
J-2A
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
J-1A
1 GANG BOX FOR AV
WITH QUAD POWER AND
(4) LAN
D-6
AV-A
SAMSUNG DM48D 48" LCD
MONITOR
TYP. 2
D-6
AV-A
SAMSUNG DM48D 48" LCD
MONITOR
D-7
AV-B
5 GANG BOX FOR AV
D-7
AV-B
J-3A
5 GANG BOX FOR AV
D-7
AV-B
J-3A
5 GANG BOX FOR AV
15
"
32
"
48
"
D-6
AV-B
SAMSUNG DM48D 48" LCD
MONITOR
TYP. 2
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
1
4
CATV
1 1
1
S
S
S
S
S
S
S
S
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
LIVING ROOM 112 -FLOOR PLAN RCP
ELEVATION CONDUITRISER
AV10
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 1/4" = 1'-0"
LIVING ROOM 112 - FLOOR PLAN
1
ESTIMATED POWER CONSUMPTION & BTU LOAD CHART
EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)
LCD MONITOR 55 3 188 563
PROJECTOR 480 1 1637 1637
EQUIPMENT RACK 1000 1 3410 3410
TOTAL BTU: 5234 5609
GENERAL NOTES:
1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE
AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN
DEDICATED CIRCUITS.
2. MECHANICAL DEVICES LOCATED WITHIN CEILING SHOULD NOT BE LOCATED NEAR CEILING
PROJECTORS. THESE DEVICES COULD INDUCE VIBRATION AT THE PROJECTORS. TAKE
PRECAUTION TO LIMIT ANY VIBRATION WITHIN THE CEILING THAT COULD BE TRANSFERRED TO
THE PROJECTORS.
3. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT
IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.
LIGHTING / DRAPE NOTES:
1. PENDANT LIGHT FIXTURES TO BE CAREFULLY COORDINATED SO THAT THEY DO NOT IMPEDE
DATA PROJECTORS CONE.
2. LIGHTING ZONES TO BE CIRCUITED AND DIMMABLE. FRONT ZONE OF LIGHTING CLOSEST TO
PROJECTION SCREENS SHOULD BE ON A SEPARATE ZONE SO THAT IT CAN BE DIMMED OR
SHUT OFF IF NECESSARY.
3. WINDOW TREATMENTS SHOULD BE PROVIDED WHERE AMBIENT LIGHT FROM OUTDOORS OR
OTHER LIGHT SOURCES THAT HAVE THE POTENTIAL TO AFFECT THE PROJECTED IMAGES ON
THE PROJECTION SCREENS.
Scale: 1/4" = 1'-0"
LIVING ROOM 112 - RCP
2
J-2C
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
AV-1C
2 GANG BOX FOR AV
INPUT PLATE WITH
POWER AND LAN
J-1C
3 GANG BOX FOR AV
BUTTON PANEL
J-3C
1 GANG BOX FOR AV
J-2B
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
AV-1B
2 GANG BOX FOR AV
INPUT PLATE WITH
POWER AND LAN
J-1B
3 GANG BOX FOR AV
BUTTON PANEL
J-3B
1 GANG BOX FOR AV
J-2A
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
AV-1A
2 GANG BOX FOR AV
INPUT PLATE WITH
POWER AND LAN
J-1A
3 GANG BOX FOR AV
BUTTON PANEL
J-3A
1 GANG BOX FOR AV
J-1
4 GANG PULL BOX FOR
AV WITH QUAD POWER,
(4) LAN, AND CATV
CB-1
PULL AREA FOR
PROJECTOR WITH
POWER AND LAN
Scale: 3/4" = 1'-0"
LIVING ROOM 112 - MONITOR ELEVATION (TYPICAL)
3
J-2C
1 GANG BOX FOR AV
WITH AC CLOCK
RECEPTACLE AND LAN
AV-1C
2 GANG BOX FOR AV
INPUT PLATE WITH
POWER AND LAN
J-1C
3 GANG BOX FOR AV
BUTTON PANEL
J-3C
1 GANG BOX FOR AV
32
"
J-4
1 GANG SCREEN SWITCH
D-4
AV-A
TANNOY CVS6 CEILING
SPEAKERS
TYP. 8
D-9
AV-B
DALITE TENSIONED
COSMOPOLITAN 76.25"H X
122"W CEILING MOUNTED
ELECTRIC PROJECTION
SCREEN
D-2
AV-A
EPSON G6470WU
PROJECTOR WITH
STANDARD LENS
D-1
AV-A
MIDDLE ATLANTIC
WRK-44SA-27
D-5
AV-A
RECESSED SAMSUNG
DM48D 48" LCD MONITOR
18' THROW DISTANCE
48
"
15
"
TO J-1
D-5
AV-A
RECESSED SAMSUNG
DM48D 48" LCD MONITOR
MOUNTED ON CHIEF
PNRIW + PAC501
TYP. 3
UNDER-CARPET
PERIMETER LOOP
SYSTEM
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
TO J-1
AV-2
2 GANG BOX FOR AV
WITH AC RECEPTACLE
AND LAN
J-5
TOUCH PANEL W/ MFR PRE CONSTRUCTION BOX
22
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
ENTRANCE VIDEOWALL
AV11
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale: 1/2" = 1'-0"
ENTRANCE VIDEO WALL FLOOR PLAN
1
ESTIMATED POWER CONSUMPTION & BTU LOAD CHART
EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)
LCD MONITOR 120 4 409 1637
TOTAL BTU: 409 1637
GENERAL NOTES:
1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE
AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN
DEDICATED CIRCUITS.
2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT
IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.
J-6
2 GANG PULL BOX FOR
AV WITH (2) LAN AND
QUAD POWER
Scale: 1" = 1'-0"
ENTRANCE VIDEO WALL ELEVATION
2
J-7
2 GANG PULL BOX FOR
AV WITH (2) LAN AND
QUAD POWER
J-6
2 GANG PULL BOX FOR
AV WITH (2) LAN AND
QUAD POWER
J-7
2 GANG PULL BOX FOR
AV WITH (2) LAN AND
QUAD POWER
74
"
51
1
/4
"
22
3
/4
"
EQ. EQ.
45
5
/8
"
80 5/8"
40 1/4"
Scale: 3/8" = 1'-0"
ENTRANCE VIDEO WALL CEILING PLAN
3
CB-2
PLENUM CEILING BOX FOR
DIRECTIONAL SPEAKER
D-15
AV-C
(4) PRIMEVIEW PRV46
46" LED MONITORS
ARRANGED IN A 2x2 TILE
WALL
39
3
/4
"
D-15
AV-C
(4) PRIMEVIEW PRV49SNG
49" LED MONITORS
ARRANGED IN A 2x2 TILE
WALL
2
AV11
3 3/4"
3 5
/8
"
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
SLAB
FLOOR
CEILING
SLAB
ELECTRICAL SCHEDULE
SYM. DESCRIPTION
STUBBED
CONDUIT
CEILING POWER OUTLET - 120V AC
AC CLOCK RECEPTACLE - 120V AC
AC DUPLEX OUTLET - 120V AC
AC QUAD OUTLET - 120V AC
LAN WITH QUANTITY
RIGID
CONDUIT
ANALOG LINE WITH QUANTITY
WALL PHONE
CATV
J-BOX
PLENUM
CABLE
CEILING PULL AREA
SHADE LVC
LIGHTING LVC
SCREEN LVC
LIGHT SWITCH
SCREEN SWITCH
J-
CB-
SH
LVC
LT
LVC
SCR
LVC
LT
SW
SS
SW
JUNCTION BOX SCHEDULE
BOX #: SIZE: FUNCTION: LOCATION:
ADD'L CABLE
BEYOND BOX
AFF
AV CLOSET
J-1 8X8 RACK PULL BOX SEE AV FLOOR PLAN 15' 18"
LIVING ROOM
J-1A 3 GANG BUTTON PANEL SEE AV FLOOR PLAN 5'-0" 32"
J-1B 3 GANG BUTTON PANEL SEE AV FLOOR PLAN 5'-0" 32"
J-1C 3 GANG BUTTON PANEL SEE AV FLOOR PLAN 5'-0" 32"
J-2A 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 48"
J-2B 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 48"
J-2C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 48"
J-3A 1 GANG HEADPHONE PLATE SEE AV FLOOR PLAN 5'-0" 32"
J-3B 1 GANG HEADPHONE PLATE SEE AV FLOOR PLAN 5'-0" 32"
J-3C 1 GANG HEADPHONE PLATE SEE AV FLOOR PLAN 5'-0" 32"
J-4 1 GANG SCREEN SWITCH SEE AV FLOOR PLAN 5'-0" 48"
J-5 MFR CONTROL PANEL SEE AV FLOOR PLAN 5'-0"
4'-6"
AV-1A 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"
AV-1B 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"
AV-1C 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"
AV-2 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"
CB-1 MANUF PLENUM CEILING BOX SEE AV RCP 10'-0" AFC
ENTRANCE VIDEO WALL
J-6 2 GANG MONITOR PULL SEE AV FP 10'-0" 74"
J-7 2 GANG MONITOR PULL SEE AV FP 10'-0" 74"
CB-2 MANUF CEILING BOX SEE AV RCP 10'-0" AFC
TECH DIRECTOR OFFICE
AV-3 2 GANG INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"
J-1C 3 GANG BUTTON PANEL SEE AV FLOOR PLAN 5'-0" 36"
NOTES:
1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.
2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS
3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.
4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.
5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.
6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,
FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME
PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS
7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.
8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS
9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL
J-1
4
CB-1
J-4
AV-1A 1
J-6 2
J-7 2
CEILING SPEAKERS
TYP. 8
PROJECTOR
SCREEN
SWITCH
(4) 1 1/4"
CONDUITS
1-1/4"
CONDUIT
1-1/4"
CONDUIT
J-2A 1
J-1A J-3A
AV-1B 1
J-2B 1
J-1B J-3B
AV-1C 1
J-2C 1
J-1C J-3C
CB-2
AV-31
READING ROOM 112
ENTRANCE VIDEO WALL
TECH DIRECTOR OFFICE
AV
CLOSET
PERIMETER LOOP
UNDER FINISHED FLOOR
AV-2 1
J-5
J-5
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
LIVING ROOM ANDENTRANCE VIDEO
WALL CONDUIT RISER
AV12
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE
OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING
AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.
FB-2A
CRESTRON DM-TX-4K-100-1G
DM INPUT
OFE LAPTOP
HDMI
VGA+A
HDMI 1
VGA 1
CRESTRON DM-MD-4X1-C
PRESENTATION SWITCHER
(HDMI)HDMI 4
OPPO BDP103
BLU-RAY PLAYER
(HDMI)VGA 3
WOLFISION VZ-8LIGHT4
DOCUMENT CAMERA
(DM)
INSTRUCTOR STATION
DA-LITE LOW
VOLTAGE
PROJECTION
SCREEN WALL
SWITCH
J-2A
2
FROM 8X1 SWITCH
COM OUT
EFROM DM-MD16X16 SLOT 1
DM OUT
COM
DA-LITE 60"X 96" CEILING RECESSED
PROJECTION SCREEN
EPSON GW6470
4500 LUMENS PROJECTOR
CRESTRON
DM-RMC-4K-SCALER -C
C
HDMICB-1A
TANNOY CVS6
CEILING SPEAKERS
TAP @ 15W
TYP. 6
SP
AV RACK
100B
J-1
8G
A
FROM CP3N
RELAY 1 & 2
C
MONITOR1
OFE PC
LAN
2
TO OPPO
BLU-RAY
(C)
LAN
FFROM AMPLIFIER #1
A DM-MD16X16 INPUT 1
B TO NETWORK SWITCH
AV-1A J-1
OFE
KEYBOARD/MOUSE
USB
USB
J-1
D TO DM-MD16X16 INPUT 2
1
FROM PC
MONITOR OUT
OFE COMPUTER
MONITOR
MONITOR2
(C)
HDMI
1
TO PC
MONITOR
DM IN
TOUCH PANEL AV NET
CUSTOM
INPUT PANEL
C TO NETWORK SWITCH
DOCUMENT CAMERA DRAWER
EXTRON CABLE
CUBBY 500 #1
(TOP)
Middle Atlantic ProductsMiddle Atlantic Products
SRSR-2-12*
CONSULTANT RACK ID PANEL
SURGEX POWER STRIP
BLANK
OFE PC
OPPO BLU-RAY PLAYER
CRESTRON DM-MD8X1-4K-C SWITCHER
BLANK
BLANK
BLANK
EQUIPMENT RACK INSIDE TEACHER
STATION
(CAT6)
(CAT6)
EXTRON CABLE
CUBBY 500 #2
(SIDE)
HDMI
VGA+A
HDMI 2
VGA 2
HDMI 3
RACK IN SIDE LECTERN
NOTES
1. RACK MAY NEED TO BE CUT DOWN BY 1 RU, OR
MORE, TO FIT INSIDE OF TEACHER STATIONS. REFER
TO DRAWING A705 FOR DETAIL OF TEACHER
STATION.
2. FLOOR BOX DEVICE PLATES WILL BE PROVIDED BY
E.C. AV CONTRACTOR SHALL COORDINATE
REQUIRED DEVICE PLATES FOR INSTALLATION OF
AV.DEVICES.
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SEMINAR 100A AVSIGNAL FLOW
AV100
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
EPSON GW5650
4500 LUMENS PROJECTOR
OFE LAPTOP
YPbPr
Channel:
1080i
52-1
232-ATSC+1
USB
Air
CONTEMPORARY RESEARCH
ATSC-232 4
HDTV TUNER #1
(ROOM 100A)
HDMI DMC-4K-HD 8
CRESTRON
DM-RMC-4K-SCALER -C
AUDIO L
AUDIO R
1
DM
C- 4K
-H
DO
DM OUT 1
DM OUT2
SLOT 1
DM
C-4K
-C
O-H
D
SLOT 2
DMC-4K-C 3
CRESTRON DM-MD16X16
MATRIX SWITCH
8G
C
HDMI
J-1 CB-1A
E
DM-RMC-4K-SCALER-C
IN 100A
8G
DMC-4K-C 5
YPbPr
Channel:
1080i
52-1
232-ATSC+1
USB
Air
CONTEMPORARY RESEARCH
ATSC-232 4
HDTV TUNER #2
(ROOM 100C)
HDMI DMC-4K-HD 9
21 21 2121
CLASS 2 WIRING
10V 50mA
SIGNAL
LIMITER/PROTECT
100-240V 0.5A, 50-60 Hz
XPA 1002 Plus
V GC
ST
AN
DB
Y
G
8
14
10
8
6
12
2
0
8
26
18
14
12
10
8
6
4
2
0
4
XPA 1002 Plus
EXTRON XPA2001
AMPLIFIER
60-850-01 #1
A
A
AUDIO L
AUDIO R
2
21 21 2121
CLASS 2 WIRING
10V 50mA
SIGNAL
LIMITER/PROTECT
100-240V 0.5A, 50-60 Hz
XPA 1002 Plus
V GC
ST
AN
DB
Y
G
8
14
10
8
6
12
2
0
8
26
18
14
12
10
8
6
4
2
0
4
XPA 1002 Plus
TANNOY CVS6
CEILING SPEAKERS W/
TAP @ 15W
TYP. 6
EXTRON XPA2001
AMPLIFIER
60-850-01 #2
SP
A
A
ROOM 100A
ROOM 100C
AUDIO L
AUDIO R
1
DM
C- 4K
-H
DO
SLOT 5
A
A
ASSISTIVE
LISTENING
RACK PLATE
CRESTRON
TSW-1052-B-S
W/ TSW-1050-TTK-B-S
HDMI
VGA+A
HDMI 1
VGA 1
CRESTRON DM-MD8X1-4K-C
PRESENTATION SWITCHER
HDMI
HDMI 2
HDMI 3
OPPO BDP103
BLU-RAY PLAYER
HDMIHDMI 4
DOCUMENT CAMERA
8GDM OUT
MONITOR1
OFE PC
HDMI 2
LAN
CAT6
LAN CAT6
H TO NETWORK SWITCH
OFE
KEYBOARD/MOUSE
USB
USB
1
FROM PC
MONITOR OUT
OFE COMPUTER
MONITOR
MONITOR2 C
HDMI
1
TO PC
MONITOR
I TO NETWORK SWITCH
DOCUMENT CAMERA DRAWER
F
TO CEILING SPEAKERS
IN 100C
DMC-4K-C 6
DMC-4K-C 7
FB-1C
J-1
FROM STUDENT
TABLE #2
FROM STUDENT
TABLE #3
FB-3C
FROM STUDENT
TABLE #4
FB-4C
TO LAN IN
FLOOR BOX
J-1
CB-1C
SAMSUNG DM48
48" LCD MONITOR #1
CRESTRON
DM-RMC-4K-SCALER-C #1
C
HDMI
8G
J-2CJ-1
DM OUT 1
DM OUT2
SLOT 3
DM
C-4K
-C
O-H
D
J-3C
SAMSUNG DM48
48" LCD MONITOR #2
CRESTRON
DM-RMC-4K-SCALER-C #2
C
HDMI
8G
SAMSUNG DM48
48" LCD MONITOR #3
CRESTRON
DM-RMC-4K-SCALER-C #3
C
HDMI
8G
J-4CJ-1
DM OUT 1
DM OUT2
SLOT 4
DM
C-4K
-C
O-H
D
J-5C
SAMSUNG DM48
48" LCD MONITOR #4
CRESTRON
DM-RMC-4K-SCALER-C #4
C
HDMI
8G
A TO HEADPHONE AMP #1
A
A
A TO HEADPHONE AMP #2
A
A
A TO HEADPHONE AMP #3
A
A
A TO HEADPHONE AMP #4
A
A
HDMI 1
CONTACT 1
TALLY OUT 1
HDMI 2
CONTACT 2
TALLY OUT 2
HDMI 3
CONTACT 3
TALLY OUT 3
TALLY OUT 4
CONTACT 4
HDMI 4
EXTRON SW4 HDMI SWITCHER
60-841-04
AUDIOA
A
FROM MONITOR
AUDIO OUT
EXTRON CABLE CUBBY 1400
#1
HDMI / CONTROL
HDMI / CONTROL
HDMI / CONTROL
HDMI / CONTROL
H/PHONE1
H/PHONE2
H/PHONE3
H/PHONE4
2 TO CABLE CUBBY #1
3 TO CABLE CUBBY #2
5 TO CABLE CUBBY #4
A
A
A
A
OFE LAPTOP
HDMI / CONTROL
OFE LAPTOP
HDMI / CONTROL
OFE LAPTOP
OFE LAPTOP
CAT6
CAT6
STUDENT TABLE #1
(TYP OF 4)
ROLLS HA43 PRO
HEADPHONE AMP #1
RACK IN SIDE LECTERN
INSTRUCTOR STATION
UNDERSIDE OF TABLE
CRESTRON
DM-TX-4K-202-C
TRANSMITTER #1
DMC-4K-C 4
J-1FB-1C
HDMI1
RS232 C
HDMI
FB-2C
8G
8G
8G
8G
2
FROM H/P
AMP OUT 1
3
FROM H/P
AMP OUT 2
4
FROM H/P
AMP OUT 3
5
FROM H/P
AMP OUT 4
A
A
A
A
A
A
A
A
H/PHONE1A
H/PHONE2A
H/PHONE3A
4 TO CABLE CUBBY #3
H/PHONE4A
DMC-4K-C 1
DMC-4K-C 2
POE
A
FROM MONITOR
AUDIO OUT
8G
D
FROM MONITOR
AUDIO OUT
GFROM POE SWITCH
8G
8G
AV RACK
SP
DM IN
EXTRON CABLE CUBBY
500
CAT6
EXTRON CABLE CUBBY 1400
#2
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
ACTIVE LEARNING 100CAV FLOW -
PRESENTATIONSYSTEM
AV101
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
4
1
POWER
RESET
AMBER : 10/100Mbps green : 1000Mpbs
3DIAG 1 2
PoE
65 87
2 3 4 5
PoE SWITCH76 8
10
99 10
MANAGED POE
NETWORK SWITCH.
CRESTRON CP3N CONTROLLER
COMA
COMB
RELAY1/2
DA-LITE LOW
VOLTAGE
PROJECTION
SCREEN WALL
SWITCH
J-2A
C
J-1
C
RELAY3/4
DA-LITE LOW
VOLTAGE
PROJECTION
SCREEN WALL
SWITCH
J-6C
J-1
DA-LITE 60"X 96" CEILING RECESSED
PROJECTION SCREEN
DA-LITE 60"X 96" CEILING RECESSED
PROJECTION SCREEN
YPbPr
Channel:
1080i
52-1
232-ATSC+1
USB
Air
CONTEMPORARY RESEARCH
ATSC-232 4
HDTV TUNER #1 (100A)
YPbPr
Channel:
1080i
52-1
232-ATSC+1
USB
Air
CONTEMPORARY RESEARCH
ATSC-232 4
HDTV TUNER #2 (100C)
B
FROM TOUCH PANEL
100A
PORT 1
PORT 2
PORT 3
C
FROM LECTERN
SWITCHER 100A
C
HFROM TOUCH PANEL
IFROM AV SWITCHER
AV-1A
PORT 4
AV RACK
IN 100B
CRESTRON DM-MD16X16
MATRIX SWITCH
C
C
ROOM 100A
ROOM 100C
FB-1C
Middle Atlantic ProductsMiddle Atlantic Products
SRSR-2-12
CONSULTANT RACK ID PANEL
SURGEX POWER STRIP
BLANK
OFE PC
OPPO BLU-RAY PLAYER
CRESTRON DM-MD8X1-4K-C SWITCHER
BLANK
BLANK
BLANK
EQUIPMENT RACK INSIDE TEACHER
STATION
CAT6 G DM-MD16X16 POE IN
CAT6
CAT6
CAT6
CAT6
PORT5
PORT6
J-1
MIDDLE ATLANTIC HHCM-1 CABLE MANAGER
CATV TUNER #2
100C
CATV TUNER #1
100A
CISCO NETWORK SWITCH - CONTROL
CRESTRON CP3N CONTROL PROCESSOR
1 RU BLANK
1 RU BLANK
CRESTRON DM-MD16X16 RPS
DIGITAL MATRIX SWITCHER
EXTRON XPA AMPLIFIERS
1 RU BLANK
ADA OUTPUT PLATE
1 RU BLANK
CONSULTANT ID PANEL
MIDDLE ATLANTIC MRK-24-26
SHARED RACK 100B
SURGEX SX-1120-RT
1 RU BLANK
NOTES
1. RACK MAY NEED TO BE CUT DOWN BY 1 RU, OR
MORE, TO FIT INSIDE OF TEACHER STATIONS. REFER
TO DRAWING A705 FOR DETAIL OF TEACHER
STATION.
2. FLOOR BOX DEVICE PLATES WILL BE PROVIDED BY
E.C. AV CONTRACTOR SHALL COORDINATE
REQUIRED DEVICE PLATES FOR INSTALLATION OF
AV.DEVICES.
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
ACTIVE LEARNING 100CCONTROL FLOW
AV101.1
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
NOTES:
1. COORDINATE AS REQUIRED FOR LECTERN AND TEACHER STATION TO ALLOW
THE INSTALLATION OF THE EXTRON CABLE CUBBY.
2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.
3. LECTERN HAS ONE CABLE CUBBY INSTALLED ON TOP AND ONE INSTALLED ON
SIDE FOR ADA
Scale:6" = 1'-0"
LECTERN / TEACHER STATION CABLE CUBBY (TYP. 3)
1
EXTRON POWER MODULE
EXTRON CABLE CUBBY 500
(BRUSHED ALUMINUM)
CABLE GROMMET
(INCL. W/ CABLE CUBBY)
NOTES:
1. AVC TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM. COORDINATE AS
REQUIRED G TO ALLOW THE INSTALLATION OF THE EXTRON CABLE CUBBY.
2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.
Scale:6" = 1'-0"
STUDENT TABLE CABLE CUBBY DETAIL (TYP. 8)
2
EXTRON POWER MODULE
TYP 2
(INCL. W/ CABLE CUBBY)
EXTRON CABLE CUBBY 1400
CABLE GROMMET
(INCL. W/ CABLE CUBBY)
EXTRON AAP
3.5MM MINI TO CAPTIVE SCREW
TYP 2
EXTRON AAP BLANK
SAMSUNG DM48E
48" LCD MONITOR
RS232
FOSTEX PMO .4D
ROOM
104
ROOM
108
ROOM
110
COMPUTER
AUDIO
HDMI
EDIT SUITE 101
XLR 1
XLR 2
XLR 3
XLR 4
XLR 5
XLR 6
HDMI 1
AUDIO 1
HDMI
DVI-D
AUDIO 1 (L&R)
A
A
A
A
A
A
VGA
AUDIO
CRESTRON MPC-M10
BUTTON CONTROLLER
WALL BELOW MONITOR
J-1
DVI1
COM A
VGA 1
OFE IMAC
J-5
C
PWR
J4
P
HDMI
A
A
J-3
TO SUITE 104
TO SUITE 104
TO SUITE 108
TO SUITE 108
TO SUITE 110
TO SUITE 110
COUNTER TOP
A
HDMI
VGA
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
URI EDIT ROOM 101
AV102
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Middle Atlantic ProductsMiddle Atlantic Products
SRSR-2-12
CONSULTANT ID RACK
SURGEX POWER STRIP
BLANK
OFE PC
OPPO BLU-RAY PLAYER
BLANK
BLANK
EQUIPMENT RACK INSIDE LECTERN
EXTRON DTP CROSSPOINT 82 4K
OFE LAPTOP
HDMI
VGA+A
HDMI 1
VGA 1
(HDMI)HDMI 4
OPPO BDP103
BLU-RAY PLAYER
(HDMI)VGA 3
WOLFISION VZ-8LIGHT4
DOCUMENT CAMERA
RACK IN SIDE LECTERN
INSTRUCTOR LECTERN
MONITOR1
OFE PC
LAN
OFE
KEYBOARD/MOUSE
USB
USB
MONITOR2
(C)
HDMI
1
TO PC
MONITOR
DOCUMENT CAMERA DRAWER
EXTRON CABLE
CUBBY 500
(TOP)
EXTRON CABLE
CUBBY 500
(SIDE)
HDMI
VGA+A
HDMI 2
VGA 2
HDMI 3
a
1
2
3
4 6
5
EXTRON
DTP CROSSPOINT 82 4K
SCALING MATRIX SWITCHER #1
(DM-8G+)DTP1B
HDMI2A HDMI
OFE PC MONITOR
ON CHIEF ARM
CAT6
NOTES
1. RACK MAY NEED TO BE CUT DOWN BY 1 RU, OR
MORE, TO FIT INSIDE OF TEACHER STATIONS. REFER
TO DRAWING A705 FOR DETAIL OF TEACHER
STATION.
2. FLOOR BOX DEVICE PLATES WILL BE PROVIDED BY
E.C. AV CONTRACTOR SHALL COORDINATE
REQUIRED DEVICE PLATES FOR INSTALLATION OF
AV.DEVICES.
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SCREENING ROOM 103AV SIGNAL FLOW #1
AV103
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
Scale:6" = 1'-0"
LECTERN CABLE CUBBY DETAIL (TYP. 2)
1
EXTRON POWER MODULE
EXTRON CABLE CUBBY 500
(BRUSHED ALUMINUM FINISH)
CABLE GROMMET
(INCL. W/ CABLE CUBBY)
NOTES:
1. COORDINATE AS REQUIRED FOR CUTTING TO ALLOW THE INSTALLATION OF
THE EXTRON CABLE CUBBY.
2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.
3. LECTERN HAS ONE CABLE CUBBY INSTALLED ON TOP AND ONE INSTALLED ON
SIDE FOR ADA
YPbPr
Channel:
1080i
52-1
232-ATSC+1
USB
Air
CONTEMPORARY RESEARCH
ATSC-232 4
HDTV TUNER
HDMI HDMI 1
8G
EXTRON
60-1271-13
DTP HDMI 4K 230 RX
DTP 1B
DTP 7
C
HDMI
EXTRON
60-1583-01
DTP CROSSPOINT 82 4K
SCALING MATRIX SWITCHER
a
1
2
3
4 6
5
8GDTP 8
HDMI
RS232
NEC X981 UHD
98" LCD 4K MONITOR
POWER
12V
0.7A MAX
HDMI2A HDMI
A
TO NETWORK
SWITCH
8G
LEON VAULT ULTIMA #1
FRONT LEFT
LEON HZ ULTIMA SOUNDBAR
CENTER
TANNOY VX5.2
SPEAKER #3
SIDE LEFT
TANNOY VX5.2
SPEAKER #4
SIDE RIGHT
TANNOY VX5.2
SPEAKER #5
REAR LEFT
TANNOY VX5.2
SPEAKER #6
REAR RIGHT
SP
J-3
J-4
J-6
J-5
J-8
J-7
SP
AV RACK
SP
SP
SP
SP
J-2
SP
SP
FRONTLHDMI 1
FRONTR
SURRR
SURRL
BACKL
BACKR
CENTER
SUB
DOWNMIX
AUDIO L
AUDIO R
A
A
A
A
A
A
A
A
A
A
LEON ACS10UT
IN WALL SUBWOOFER
AUDIO L
AUDIO R
CRESTRON
HD-XSP SURROUND
SOUND PROCESSOR
J-1
J-9
AMPLIFIER1CHANNEL A
AMPLIFIER2
CHANNEL B
AMPLIFIER3
CHANNEL C
AMPLIFIER4
CHANNEL D
AMPLIFIER5
CHANNEL E
AMPLIFIER6CHANNEL F
BOSE PM8250N AMPLIFIER
AMPLIFIER7CHANNEL G
AMPLIFIERCHANNEL 1
8G
PROGRAM1
AUDIO L
AUDIO R
RACK PANEL
DOWNMIX
AUDIO L
AUDIO R
AUDIO L
AUDIO R
AUDIO L
AUDIO R
A
A
AUDIO L
AUDIO R
6
C
FROM SURROUND
PROCESSOR
C
TO DTP CROSSPOINT 42
INPUT 6
DM IN
AV NET
CUSTOM
MAAP
MODULES
A
A
A
J-1 J-2
A
8G
NOTES
1. OUTPUTS OF DTP CROSSPOINT ARE INDEPENDENTLY
SCALABLE.
2. HD-XSP SUPPORTS HD CONTENT ONLY. THE
CORRESPONDING HD OUTPUT WILL NEED TO BE SCALED
TO HD.
3. INPUT SOURCES ARE NATIVELY SET TO MULTICHANNEL.
THE TWO-CHANNEL DOWNMIX FROM HD-XSP WILL BE
USED IN MODES REQUIRING TWO CHANNEL OPERATION
AND TO FEED THE ASSISTIVE LISTENING OUTPUT PLATE.
4. 4K VIDEO PATH WILL FOLLOW FROM INSTRUCTOR
STATION TO THE DISPLAY.
CAT6
CAT6
FB-1
B
TO NETWORK
SWITCH
J-1
FB-2
D TO SOUNDBAR
DFROM AMPLIFIER SP
DM IN
AV NET
CUSTOM
MAAP
MODULES
LEON VAULT ULTIMA #2
FRONT RIGHT
LEON 1000W
AMPLIFIER
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SCREENING ROOM 103AV SIGNAL FLOW #2
AV103.1
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
PORT 1
PORT5
PORT4
4
1
POWER
RESET
AMBER : 10/100Mbps green : 1000Mpbs
3DIAG 1 2
PoE
65 87
2 3 4 5
PoE SWITCH76 8
10
99 10
PORT 2
CRESTRON
HD-XSP SURROUND
SOUND PROCESSOR
EXTRON 60-1583-01
DTP CROSSPOINT 82 4K
SCALING MATRIX SWITCHER #2
a
1
2
3
4 6
5
BOSE PM8250N AMPLIFIER
PORT6
CRESTRON CP3N CONTROLLER
COMA
SUBNET
LAN
AFROM FLOOR BOX CAT6
CAT6
CAT6
CRESTRON
TSW-1052-B-S
W/ TSW-1050-TTK-B-S
PORT 3BFROM FLOOR BOX CAT6
4
1
POWER
RESET
AMBER : 10/100Mbps green : 1000Mpbs
3DIAG 1 2
PoE
65 87
2 3 4 5
PoE SWITCH76 8
10
99 10
CISCO SF302-08P
NETWORK SWITCH W/ POE #1
PORT5 CAT6
EXTRON
60-1583-01
DTP CROSSPOINT 82 4K
SCALING MATRIX SWITCHER #1
a
1
2
3
4 6
5
PORT1 CAT6
OPPO BDP103
BLU-RAY PLAYER
RS232/DTP6 C
PORT7 CAT6
INSTRUCTOR STATION
RACK IN
INSTRUCTOR STATION
YPbPr
Channel:
1080i
52-1
232-ATSC+1
USB
Air
CONTEMPORARY RESEARCH
ATSC-232 4
HDTV TUNER
LAN 2
RS232/DTP 2
COMB
AV RACK
TO FLOOR BOX
CISCO SF302-08P
NETWORK SWITCH W/ POE #2
FB-1 J-1
FB-2
CAT6
C
C
CAT6
RS232/DTP 6
COMC C
MIDDLE ATLANTIC HHCM-1 CABLE MANAGER
CATV TUNER
CISCO NETWORK SWITCH - CONTROL
CRESTRON CP3N CONTROL PROCESSOR
1 RU BLANK
1 RU BLANK
ADA OUTPUT PLATE
1 RU BLANK
CONSULTANT ID PANEL
MIDDLE ATLANTIC MRK-24-26
RACK
EXTRON DTP CROSSPOINT 84 4K
SWITCHER
CRESTRON HD-XSP PROCESSOR
BOSE PM8500N
8 CHANNEL AMPLIFIER
1 RU BLANK
1 RU BLANK
BLANKS
SURGEX SX-1120-RT
1 RU BLANK
PORT7 CAT6
LIGHTING/SHADES CONTROLLER
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SCREENING ROOM 103CONTROL FLOW
AV103.2
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
THREE PERSON TABLE
NOTES:
1. SYSTEM FLOW DIAGRAM IS BASED UPON THE EXTRON TEAM WORK 400
SYSTEM.
2. AV CONTRACTOR TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM.
COORDINATE AS REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION
OF THE EXTRON CABLE CUBBY.
3. EQUIPMENT SHOULD BE SECURED TO THE UNDERSIDE OF THE TABLE SO THAT
IT DOES NOT FALL OFF.
4. CABLING BETWEEN THE HEADPHONE AMPLIFIER LOOP THROUGH AND THE
MACKIE REFERENCE MONITORS IS THROUGH A GROMMET IN THE TABLE.
RS232
CRESTRON MPC-M10
BUTTON CONTROLLER
COM A
PWR
J4
WALL BELOW MONITOR
C
P
MACKIE HRMK2
REFERENCE MONITOR #1
(TURNED SIDEWAYS BELOW
DISPLAY)
MACKIE HRMK2
REFERENCE MONITOR #2
(TURNED SIDEWAYS
BELOW DISPLAY)
A
A
FROM OUTPUT OF
OFE MIXER
A
A
FROM OUTPUT OF
OFE MIXER
SAMSUNG DM48E
48" LCD MONITOR
ROOM
101
ROOM
108
ROOM
110
COMPUTER
AUDIO
HDMI
EDIT SUITE 104
XLR 1
XLR 2
XLR 3
XLR 4
XLR 5
XLR 6
HDMI
AUDIO
A
A
A
A
A
A
VGA
J-5
TO SUITE 101
TO SUITE 101
TO SUITE 108
TO SUITE 108
TO SUITE 110
TO SUITE 110
HDMI
VGA
AUDIO
J-2
HDMI
VGA
A
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
EDIT ROOM 104 AVSIGNAL FLOW
AV104
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
HDMI 1
CONTACT 1
TALLY OUT 1
HDMI 2
CONTACT 2
TALLY OUT 2
HDMI 3
CONTACT 3
TALLY OUT 3
HDMI 4
CONTACT 4
TALLY OUT 4
R
EXTRON CABLE
CUBBY 700
OFE LAPTOP
EXTRON SW4
HDMI SWITCHER
OFE LAPTOP
OFE LAPTOP
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
HDMI / CONTROL
HDMI / CONTROL
J-1x J-2x
SAMSUNG DM48E
48" LCD MONITOR
HDMI 1
HDMI / CONTROL
HDMI / CONTROL
RS232
UNDERSIDE OF TABLE IN
ACCESSIBLE TABLE PEDESTAL
OR ATTACHED TO UNDERSIDE
OF TABLE TOP
TOP OF TABLE
HDMI / CONTROL
A
FROM H/PHONE
AMP 1
ROLLS HA43 PRO
HEADPHONE AMP #1
AUDIOA
E
FROM MONITOR
AUDIO OUT
H/PHONE1
H/PHONE2
H/PHONE3
A
TO CABLE
CUBBY
B
TO CABLE
CUBBY
C
TO CABLE
CUBBY
A
A
A
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
B
FROM H/PHONE
AMP 2
C
FROM H/PHONE
AMP 3
AUDIO L/R
HDMI1
RS232
HDMI
C
NOTES:
1. THE ABOVE SYSTEM IS TYPICAL FOR TWO (2) STATIONS IN ROOM 106
2. SYSTEM FLOW DIAGRAM IS BASED UPON THE EXTRON TEAM WORK 400
SYSTEM.
3. AV CONTRACTOR TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM.
COORDINATE AS REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION
OF THE EXTRON CABLE CUBBY.
OFE LAPTOP
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
HDMI / CONTROL
D
FROM H/PHONE
AMP 4
H/PHONE4 D
TO CABLE
CUBBY
A
E
TO HEADPHONE
AMP
A
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
SPEAKING-WRITINGLAB 106 AV SIGNAL
FLOW
AV105
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
NOTES:
1. AVC TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM. COORDINATE AS
REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION OF THE EXTRON
CABLE CUBBY.
2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.
Scale:6" = 1'-0"
CABLE CUBBY DETAIL (TYP. 2)
1
EXTRON POWER MODULE
(INCL. W/ CABLE CUBBY)
EXTRON CABLE CUBBY 700
CABLE GROMMET
(INCL. W/ CABLE CUBBY)
EXTRON 70-098-11
TWO STEREO 3.5 MINI JACKS
HDMI 1
CONTACT 1
TALLY OUT 1
HDMI 2
CONTACT 2
TALLY OUT 2
HDMI 3
CONTACT 3
TALLY OUT 3
HDMI 4
CONTACT 4
TALLY OUT 4
R
EXTRON CABLE
CUBBY 1400
OFE LAPTOP
EXTRON SW4
HDMI SWITCHER
OFE LAPTOP
OFE LAPTOP
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
HDMI / CONTROL
HDMI / CONTROL
J-1A J-2A
SAMSUNG DM48E
48" LCD MONITOR
HDMI 1
HDMI / CONTROL
HDMI / CONTROL
MAINS
UNDERSIDE OF TABLE IN
ACCESSIBLE TABLE PEDESTAL
OR ATTACHED TO UNDERSIDE
OF TABLE TOP
TOP OF TABLE
HDMI / CONTROL
1
FROM H/PHONE
AMP 1
ROLLS HA43 PRO
HEADPHONE AMP #1
AUDIOA
A
FROM MONITOR
AUDIO OUT
H/PHONE1
H/PHONE2
H/PHONE3
1
TO CABLE
CUBBY
2
TO CABLE
CUBBY
3
TO CABLE
CUBBY
A
A
A
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
2
FROM H/PHONE
AMP 2
3
FROM H/PHONE
AMP 3
AUDIO L/R
HDMI1
RS232
HDMI
C
NOTES:
1. THE ABOVE SYSTEM IS TYPICAL FOR TWO (2) STATIONS IN ROOM 106
2. SYSTEM FLOW DIAGRAM IS BASED UPON THE EXTRON TEAM WORK 400
SYSTEM.
3. AV CONTRACTOR TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM.
COORDINATE AS REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION
OF THE EXTRON CABLE CUBBY.
OFE LAPTOP
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
HDMI / CONTROL
3
FROM H/PHONE
AMP 4
H/PHONE4 4
TO CABLE
CUBBY
A
ROOM
101
ROOM
104
ROOM
110
EDIT SUITE 106
XLR 1
XLR 2
XLR 3
XLR 4
XLR 5
XLR 6
A
A
A
A
A
A
J-3A
TO SUITE 101
TO SUITE 101
TO SUITE 104
TO SUITE 104
TO SUITE 110
TO SUITE 110
WALL BELOW TV
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
COLLABORTE & EDITSUITE 108
AV106
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
NOTES:
1. AVC TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM. COORDINATE AS
REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION OF THE EXTRON
CABLE CUBBY.
2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.
Scale:6" = 1'-0"
CABLE CUBBY DETAIL
1
EXTRON POWER MODULE
(INCL. W/ CABLE CUBBY)
EXTRON CABLE CUBBY
1400
CABLE GROMMET
(INCL. W/ CABLE CUBBY)
EXTRON AAP TWO STEREO
3.5 MINI JACKS
TYP 2
EXTRON AAP 1 SPACE
BLANK
HDMI 1
CONTACT 1
TALLY OUT 1
HDMI 2
CONTACT 2
TALLY OUT 2
HDMI 3
CONTACT 3
TALLY OUT 3
HDMI 4
CONTACT 4
TALLY OUT 4
R
EXTRON CABLE
CUBBY 600S
60-525-01
OFE LAPTOP
EXTRON SW4
HDMI SWITCHER
OFE LAPTOP
OFE LAPTOP
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
HDMI / CONTROL
HDMI / CONTROL
J-1B J-2B
SAMSUNG DM48E
48" LCD MONITOR
HDMI 1
HDMI / CONTROL
HDMI / CONTROL
MAINS
UNDERSIDE OF TABLE IN
ACCESSIBLE TABLE PEDESTAL
OR ATTACHED TO UNDERSIDE
OF TABLE TOP
THREE PERSON TABLE
HDMI / CONTROL
1
FROM H/PHONE
AMP 1
ROLLS HA43 PRO
HEADPHONE AMP #1
AUDIOA
A
FROM MONITOR
AUDIO OUT
H/PHONE1
H/PHONE2
H/PHONE3
1
TO CABLE
CUBBY
2
TO CABLE
CUBBY
3
TO CABLE
CUBBY
A
A
A
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
2
FROM H/PHONE
AMP 2
3
FROM H/PHONE
AMP 3
HDMI1
RS232
HDMI
C
NOTES:
1. THE ABOVE SYSTEM IS TYPICAL FOR TWO (2) STATIONS IN ROOM 106
2. SYSTEM FLOW DIAGRAM IS BASED UPON THE EXTRON TEAM WORK 400
SYSTEM.
3. AV CONTRACTOR TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM.
COORDINATE AS REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION
OF THE EXTRON CABLE CUBBY.
OFE LAPTOP
PULL UP HDMI
CABLE WITH SHOW
ME BUTTON
HDMI / CONTROL
3
FROM H/PHONE
AMP 4
H/PHONE4 4
TO CABLE
CUBBY
A
ROOM
101
ROOM
104
ROOM
108
EDIT SUITE 110
XLR 1
XLR 2
XLR 3
XLR 4
XLR 5
XLR 6
A
A
A
A
A
A
J-3B
TO SUITE 101
TO SUITE 101
TO SUITE 104
TO SUITE 104
TO SUITE 108
TO SUITE 108
WALL BELOW TV
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
COLLABORTE & EDITSUITE 110
AV107
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
NOTES:
1. AVC TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM. COORDINATE AS
REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION OF THE EXTRON
CABLE CUBBY.
2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.
Scale:##########
CABLE CUBBY DETAIL
1
EXTRON POWER MODULE
(INCL. W/ CABLE CUBBY)
EXTRON CABLE CUBBY
1400
CABLE GROMMET
(INCL. W/ CABLE CUBBY)
EXTRON AAP
TWO STEREO 3.5 MINI JACKS
TYP 2
EXTRON AAP
1 SPACE BLANK
EPSON GW5650
4500 LUMENS PROJECTOR
CRESTRON
DM-RMC-SCALER -C
DM OUT 1
70V
HDMI 1
DM 6
8G
C
HDMI
CB-1
TANNOY CVS6
CEILING SPEAKERS W/
TAP @ 15W
TYP. 8
AV-2
SAMSUNG DM48
48" LCD MONITOR #1
ROLLS HA43 PRO
HEADPHONE AMP #1
AUDIO L/R
H/PHONE1
H/PHONE2
H/PHONE3
A
A
A
CRESTRON DM-TX-201-C-2G
DM TRANSMITTER #1
C
HDMI
A
AV INPUT PLATE
(1) CRESTRON MP-WP152
(1) CRESTRON MP-WP130
8G
RS232
HDMI 1
CATVRF
LANCAT6
H/PHONE4A
J-3xJ-2x
PORT 1 PORT5
4
1
POWER
RESET
AMBER : 10/100Mbps green : 1000Mpbs
3DIAG 1 2
PoE
65 87
2 3 4 5
PoE SWITCH76 8
10
99 10
PORT 2
PORT 3
CISCO SF302-08P
NETWORK SWITCH W/ POE
PORT 4
MIC 1M
CRESTRON DMPS3-200-C
DIGITAL PRESENTATION PROCESSOR
ANTENNA A
MIC
ANTENNA B
SENNHEISER 300 RECEIVER W/ CARDIOID
HANDHELD AND CARDIOD LAVALIER
HEADPHONE PLATE
VGAVGA 1
AUDIO
A
CRESTRON MPC-M10
BUTTON CONTROLLER #1
COM A
PWR
AUIDIO L/R
A LINE
LOOP OUT
PERIMETER
LOOP
(UNDER
FINISHED FLOOR)
LISTEN
TECHNOLOGIES
ILD500 AMPLIFIER
PROGRAM
AUDIO L
AUDIO R A
SP
RELAY1/2
DA-LITE LOW
VOLTAGE
PROJECTION
SCREEN WALL
SWITCH
J-4
DA-LITE 76.25" X 122" CEILING RECESSED
PROJECTION SCREEN
YPbPr
Channel:
1080i
52-1
232-ATSC+1
USB
Air
CONTEMPORARY RESEARCH
ATSC-232 4
HDTV TUNER
HDMI
C
SP
J-1
COMA
A
TO CONTEMPORARY
RESEARCH TUNER
A
FROM DMPS3-200-C
COM A
C
C
AV RACK
(IN STORAGE CLOSET)
MONITOR LOCATION
(TYPICAL OF 3)
LAN
J-2xJ-1x
P
CAT6
AV-1x
B TO NETWORK SWITCH
AT MONITOR LOCATION
TO CLIENT NETWORK
TO CATV (FUTURE)
CRESTRON MPC-B10
BUTTON CONTROLLER
CAT6 LAN
B
FROM CRESTRON MPC-M10
BUTTON CONTROLLER #1
CAT6
CAT6
CAT6
CAT6
J-1
AV-1A
B
FROM CRESTRON MPC-M10
BUTTON CONTROLLER #2
B
FROM CRESTRON MPC-M10
BUTTON CONTROLLER #3
AV-1B
AV-1C
SKM300 G3 HANDHELD W/ E835
SK300 G3 BODYPACK W/ ME4
MIDDLE ATLANTIC HHCM-1 CABLE MANAGER
CATV TUNER
CISCO NETWORK SWITCH - CONTROL
1 RU BLANK
LISTEN TECHNOLOGIES ILD5000
1 RU BLANK
CONSULTANT ID PANEL
MIDDLE ATLANTIC MRK-24-26
CRESTRON DMPS3-200-C
WIRELESS MICROPHONE
1 RU BLANK
BLANK
3RU DRAWER
1 RU BLANK
2 RU BLANK
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
LIVING ROOM AVSIGNAL FLOWS
AV108
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
CRESTRON
DM-RMC-SCALER -C
C
HDMI
PRIMEVIEW PRV49SNG
49" LCD MONITOR #1
HDMI 1
RS232
CRESTRON MPC-B10
BUTTON CONTROLLER
IN TECH DIRECTORS
OFFICE
AUDIO L
AUDIO R
HOLOSONICS AS-26I-W
SPOTLIGHT SPEAKER
P
A
A
DVI
AV-4
CB-1
RS232
PRIMEVIEW PRV49SNG
49" LCD MONITOR #2
HDMI 1
RS232
DVI
RS232
PRIMEVIEW PRV49SNG
49" LCD MONITOR #3
HDMI 1
RS232
DVI
RS232
PRIMEVIEW PRV49SNG
49" LCD MONITOR #4
HDMI 1
RS232
DVI
RS232
C
HDMI
C
HDMI
C
HDMI
P
CAT6
DM-9G
J-6
POWER SUPPLY AT VIDEO
WALL
J-5
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
DIGITAL SIGNAGE AVSIGNAL FLOWS
AV109
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
SIDE
9"
B
C
6 1/4"
12"
A
FRONT
D-5
AVA
D-1
AVA
D-2
AVA
D-3
AVA
D-4
AVA
D-6
AVA
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
MIDDLE ATLANTIC MRK-2127
1" = 1'-0" AVCAVC
3 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
PROJECTOR MOUNTING
2" = 1'0" AVCAVC
2 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
DALITE TENSIONED ADVANTAGE ELECTROL
3/4" = 1'-0" AVCAVC
2
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
TANNOY CVS6 CEILING SPEAKERS
1-1/2" = 1'-0" AVCAVC
20 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
RECESSED 48" LED MONITOR
1" = 1'-0" AVCAVC
1 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
48" LED MONITOR
1" = 1'-0" AVCAVC
1
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
AV DETAILS
AVA
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
2'-3 1/2"
2'-0
1
/4
"
2'-0 1/4"
4'-0
1
/2
"
4'-0
1
/2
"
2'-3 5/8"
RE
FE
R T
O A
V C
ON
DU
IT
R
IS
ER
S F
OR
M
OU
NT
IN
G H
EIG
HT
S
2'-3
5
/8
"
3'-7 3/8"
7 1/2"
2"
2"
2'-3
3
/8
"
RE
FE
R T
O A
V C
ON
DU
IT
R
IS
ER
S F
OR
M
OU
NT
IN
G H
EIG
HT
S
3'-7 3/8"
CHIEF CMS012W 12" WHITE
EXTENSION COLUMN BY AVC
CHIEF WHITE PROJECTOR MOUNT
BY AVC
PROJECTOR BY AVC
CEILING TILE
BUILDING STRUCTURE BY
GC
SIGNAL CABLES
UNISTRUT TO ATTACH TO
STRUCTURE ABOVE BY
THREADED ROD BY GC
CHIEF CMA110 8" CEILING
PLATE BY AVC
THREADED ROD TO ATTACH
TO UNISTRUT BY GC
10"
TO
B
E D
ET
ER
MIN
ED
IN
F
IE
LD
CEILING POWER
*TO BE LOCATED AS CLOSE TO
PIPE LOCATION AS POSSIBLE
POWER CABLE
TO SCREEN
IMAGE HEIGHT [A] IMAGE WIDTH [B] CASE LENGTH [C] QUANTITY BLACK DROP
60"
96" 114" 2 12
STRUCTURE ABOVE BY GC
SECURE SPEAKER TO STRUCTURE
ABOVE
CEILING TILE BY GC
11"
10
1
/4
"
6 5
/8
"
8"
3"
9 1/8"
3/4" THREADED ROD TO
STRUCTURE ABOVE BY GC
COMPUTER
12
12
12
AUDIO
HDMI
12
12
12
12 5/8"
9 1/8"
18
5
/8
"
15
1
/8
"
7 1/8"
13
1
/8
"
D-11
AVB
D-7
AVB
D-8
AVB
D-9
AVB
D-10
AVB
D-12
AVB
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
5 GANG AV PLATE
6" = 1'-0" AVCAVC
4 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
LOWELL LDTR
1" = 1'-0" AVCAVC
1 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
DALITE COSMOPOLITAN ELECTROL
3/4" = 1'-0" AVCAVC
1
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
CHIEF NW2 WALL MOUNTED RACK
1-1/2" = 1'-0" AVCAVC
1 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
TANNOY VX 5.2
3" = 1'-0" AVCAVC
4 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
LEON ACS10UT SUBWOOFER
1-1/2" = 1'-0" AVCAVC
1
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
AV DETAILS
AVB
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
2'-1
7
/8
"
1'-6 1/8"
1'-6
1
/8
"
1'-6
3
/8
"
1'-5
7
/8
"
1'-6 1/8"
1'-3
7
/8
"
11 3/4"
5 1/4"
1'-10 1/8"
1'-6
3
/8
"
122"
76
.2
5"
143.5"
4 5
/8
"
5 3
/4
"
ROOMS: 101 & 104
ROOMS: 108 & 110
NEUTRIK COMBO
#NCJ9FI-S
(TYP)
WIRING DIAGRAM
PLATE TYPE:ALUMINUM
ENGRAVING COLOR: WHITE
PLATE COLOR: BLACK
BASE OF SUBWOOFER IS REMOVED FOR INSTALLATION
FRONT VIEW RIGHT SIDE VIEW
TOP VIEW
0.36 MINIMUM TABLE THICKNESS
2.86 MAXIMUM TABLE THICKNESS
6.13
6.13
4.09
9.63 4.83
DETAIL A
SIDE VIEW FRONT VIEW
TOP VIEW
SEE DETAIL A
7.17
10.32
13.82
8.49
0.44
6.41
5.73
6.67
9.82
BOTTOM VIEW
D-17
AVC
D-13
AVC
D-14
AVC
D-15
AVC
D-16
AVC
D-18
AVC
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
CRESTRON MPC-B/M CONTROLLERS (TYPICAL)
NTS AVCAVC
6 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
SHARP PN-R903 WITH LEON SOUNDBAR
3/4" = 1'-0" AVCAVC
1 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
LEON VAULT IN-WALL SPEAKERS
3" = 1'-0" AVCAVC
2
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
LEON SOUNDBAR
3" = 1'-0" AVCAVC
1 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
EXTRON CABLE CUBBY 500
3" = 1'-0" AVCAVC
5 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
EXTRON CABLE CUBBY 1400
3" = 1'-0" AVCAVC
10
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
AV DETAILS
AVC
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
PREMIER AM300
MOUNT
PLYWOOD
BLOCKING BY GC
WALL STUDS BY GC
CHIEF PAC521P
PROVIDED BY GC
INSTALLED BY GC
MONITOR BY AVC
4"
9 1/4"
4 3/4"
LENGTH OF SOUND BAR IS THE WIDTH OF NICHE. VERIFY LENGTH IN FIELD.
D-22
AVD
D-18
AVD
D19
AVD
D-20
AVD
D-21
AVD
D-23
AVD
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
MIDDLE ATLANTIC SRSR-2-X RACK
NTS AVCAVC
3 TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:AVC
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:AVC
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
TITLE:
SCALE:
QUANTITY:
INSTALLED BY:SUPPLIED BY:
DATE:
FILE:
DATENO BY DESCRIPTION
C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.
JOB NO.:
DRAWN BY:
AV BID SET
12.16.15
1129
Harrington School of Communication & Media
University of Rhode IslandKingston, RI
MBH
AV DETAILS
AVD
ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com
top related