ats-186k series - aqua t maximum design flow rate. contact ats for application design and uv sizing...
Post on 15-Mar-2018
257 Views
Preview:
TRANSCRIPT
All ATS Units areProudly Made:
in the
U.S.A.
4 Log (99.99%) Bacteria, Cryptosporidium and Virus Reduction at >186,000uws/cm2 (186mJ/cm2) UV Dose • Amalgam High Output UV Lamps • 12,000 Hour Lamp Life • UV Chamber Overheat Control • UV Sight Port • Flange or Threaded Inlet / • Internal Water Flow Diverter Outlet Connections • Internal Multi-Level Quartz Sleeve Stabilizer • Internal Multi-Level Flow Balance System • Nema 4 Type Electrical Box Enclosure • Removable UV Lamp / • Fused Circuits Quartz Sleeve Service Rack • Power ON/OFF Switch • UV Intensity Monitor with • Drain NIST Traceable Calibrated UV Sensor • Remote PLC Monitoring Connection • Multi-Level UV Monitoring and Alarms
Amalgam Short Vertical UV Systems
ATS-186K SERIES U V S Y S T E M S
ATS-186K SERIES U V S Y S T E M S
Control System Stand (optional)
Wall mounted Control System (standard)
4 Log (99.99%) Reduction of Bacteria, Cryptosporidium and Virus
WQA Gold Seal / ANSI NSF 61 Approved
ATS MODEL UV DOSE FLOW GPM KW @ 120V AMPS @ 120VSTANDARD
INLET/OUTLET PIPE SIZE MNPT
UV CHAMBER DIMENSIONS
HxWxD”
ESTIMATED SHIPPING WEIGHT
Aqua Treatment Service, Inc194 Hempt Rd,
Mechanicsburg, PA 17050800 . 224 . 7476 fax: 800 . 787 . 0197
www.aquat.com
ATS-186K-10
ATS-186K-20
ATS-186K-40
ATS-186K-60
ATS-186K-80
ATS-186K-120
ATS-186K-240
ATS-186K-480
ATS -THERM Adjustable Setting Thermistor Overheat Safety Control
ATS -STAND Control Box Mounting Stand (powder coated)
ATS - SP 1/4” Sample Port on Inlet/Outlet Riser
ATS - 304NCB 304 SS #4 Brushed Finish on Nema 4 Type Control Box
ATS - LT UV Light Traps on Inlet/Outlet
ATS - STC Sanitary-Tri-Clamp Fittings
ATS - MW Manual Quartz Slaave Wiper
ATS - 316 SS 316 Stainless Steel Wetted Parts
220V Specs are available upon request. ATS-186K UV Models provide a minimum of 186mJ/cm2 UV Dose within the UVT range and maximum design flow rate. Contact ATS for application design and UV sizing criteria.
The ATS-186K UV System has been Tested and Validated per UVDGM by an Independent 3rd Party Organization
Flow & UV System Dose for 4Log Reduction of Bacteria, Virus, Cysts and Adenovirus per USEPA UV Disinfection Guideline Manual (EPA 815-R-06-007) TheATS-186KUVSystemhasbeenevaluated,performancetested,andverifiedbyandIndependent 3rd Party Organization at the USEPA Test and Evaluation Facility i Cincinnati, Ohio.
>186,000uws/cm2 (186mJ/cm2) 10 0.36 3.0 1” 47.5” X 8.5” X 8.5” 65 lbs >186,000uws/cm2 (186mJ/cm2) 20 0.72 6.0 1” 47.5” X 11.5” X 11.5” 85 lbs >186,000uws/cm2 (186mJ/cm2) 40 0.84 7.0 1 1/2” 47.5” X 12.5” X 12.5” 75 lbs >186,000uws/cm2 (186mJ/cm2) 60 0.96 8.0 2” 47.5” X 14.5” X 14.5” 95 lbs. >186,000uws/cm2 (186mJ/cm2) 80 1.2 10.0 2” 47.5” X 14.5” X 14.5” 165 lbs. >186,000uws/cm2 (186mJ/cm2) 120 1.44 12.0 3” 47.5” X 16.5” X 16.5” 185 lbs >186,000uws/cm2 (186mJ/cm2) 240 2.16 18.0 4” 47.5” X 22.5” X 22.5” 195 lbs. >186,000uws/cm2 (186mJ/cm2) 480 2.64 22.0 4” 47.5” X 30.5” X 30.5” 225 lbs.
top related