3
Precidium™ meets or exceeds the following test standards.
aStm teSt DeSCrIPtIon reSuLt
ASTM D4541 Pull-off strength - aluminum 1000 psi - adhesive; 1000 psi - adhesive; 1300 psi - adhesive
ASTM D4541 Pull-off strength - wood 750 psi - adhesive; 600 psi - substrate; 820 psi - substrate
ASTM D4541 Pull-off strength - fiberglass 1150 psi - substrate; 1150 psi - substrate; 1000 psi - adhesive
ASTM D4541 Pull-off strength - primer adhesion to body-fill 600 psi - substrate fails
ASTM D4541 Pull-off strength - primer adhesion to wood 500 psi - substrate fails
ASTM D4541 Pull-off strength - body-fill to wood 600 psi - substrate fails
ASTM D4541 Pull-off strength - wood cohesive 500 psi - substrate fails
ASTM D412 Tensile elongation 199%
ASTM C1028 Coefficient of friction 0.6-1.0
ASTM D4060 Taber abrasion resistance (1000 cycles, 1000 gr load)
60 mg CS-17 wheel; 180 mg H-18 wheel
ASTM D412 Tensile strength 1820 psi
ASTM D624 Tear strength 335
ASTM D2240 Durometer hardness 53
ASTM E662 Specific optical density of smoke generated by solid materials
Ds@1.5 minutes - maximum: 100
Ds@4.0 minutes - maximum: 200
Dm@15.0 minutes - maximum: 300
Dm@20.0 minutes - maximum: 300
ASTM E162 Flammability of materials using a radiant heat energy source
Flame spread of 22.60
ASTM E84-05 Surface burning characteristics of materials Flame spread of 20; smoke developed rating of 115
ASTM E648 Critical radiant flux using radiant heat energy source
Critical radiant flux of ≥0.50 W/cm2
ASTM E1354 Cone calorimeter Maximum heat release rate: <150 kW/m2
Average heat release rate at 3 minutes: <100 kW/m2
Average heat release ignition to flameout: <50 kW/m2