as built - heathrow logistics park€¦ · all openings and junctions. u-values : pðn roof: 0.18...
Post on 31-Jul-2020
2 Views
Preview:
TRANSCRIPT
3580
583
3580
583
1 2 3
1a 2a
34
54
80
00
80
00
80
00
80
00
80
00
80
00
80
00
20
59
55
13
80
00
6688 8000
328
10552
1635 636016
75
2150
49
00
31
00
358058
33580
583
75
.0
26
b
etw
ee
n cla
dd
in
g ra
ils
102.360 between grid and cladding rail
line of plant deck over
2646
813
AA
BB
C
D
E
F
G
H
J
K
LL
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1a 2a
C1
D1
E1
F1
G1
H1
J1
K1
34
54
80
00
80
00
80
00
80
00
80
00
80
00
80
00
20
59
55
13
80
00
6688 8000 8000 80008000 80008000 8000 8000 80008000 80008000
55
13
80
00
80
00
80
00
80
00
80
00
80
00
80
00
80
00
55
13
328
10552
1635 636016
75
B1
2150
49
00
31
00
207
01
GROUND FLOOR PLAN
1:250
FWC
DIS.
WC
LIFT
STAIR 1
MWC
CL
SHW
RECEPTION
UNIT 3
STAIR 2
207
02
FIRST FLOOR PLAN
1:250
FWC
DIS.
WC
LIFT
STAIR 1
MWC
CL
SHW
VOID
OPEN PLAN OFFICE
STAIR 2
TP
TP
03
207
KEY PLAN
LOCATION OF UNITS
NTS
HEATHROW LOGISTICS PARK
UNIT 3 FLOOR PLANS
BLACKROCK & GRAFTONGATE
JAN 2016 1:250 @ A1 NSC
AS BUILT
MS
30639-RE-207G
1
2
3
4
DG 16
DG 17
DG 18 DG 19
DG 20
DG 21
DG 22
DG 23
DG 24
LD 01
LD 02 LD 03 LD 04 LD 05 LD 06LD 07 LD 08 LD 09
LD 10
ENSURE SEALING OF ALL JUNCTIONS TO COMPLY WITH PART L.
NOTES:
SUBJECT TO STATUTORY CONSENTS
SUBJECT TO SURVEY
BASED ON OS MAP REPRODUCED BY PERMISSION OF
CONTROLLER OF HM STATIONARY OFFICE (c) CROWN
COPYRIGHT
COPYRIGHT RESERVED
DO NOT SCALE THIS DRAWING
DO NOT USE ELECTRONIC VERSIONS OF THIS DRAWING TO
DETERMINE DIMENSIONS UNLESS SPECIFICALLY
AUTHORISED BY MICHAEL SPARKS ASSOCIATES
IF USING AN ELECTRONIC VERSION OF THIS DRAWING
FIGURED DIMENSIONS TAKE PRECEDENCE AND NOTIFY
MICHAEL SPARKS ASSOCIATES OF ANY DISCREPANCIES
PROVIDE ONE HOUR FIRE PROTECTION TO UPPER
FLOORS CONSTRUCTION AND ONE HOUR FIRE
PROTECTION
TO SUPPORTING STRUCTURE.
COMPLY WITH ALL PARTS OF APPROVED DOCUMENTS
IN PARTICULAR PART B, PART L2 AND PART M.
ALL DIMENSIONS TO BE CHECKED ON SITE.
STEEL COLUMN SIZES TO BE CONFIRMED AND TOLERANCES TO BE AGREED.
NOTE:
ROOF AND WALL CLADDING TO BE DESIGNED
BY SPECIALIST CONTRACTOR.
CLADDING DETAILS TO BE READ IN CONJUNCTION
WITH THE SPECIFICATION AND ALL RELEVANT
BRITISH STANDARDS.
INCLUDE VAPOUR BARRIER TAPE AROUND
ALL OPENINGS AND JUNCTIONS.
U-Values W/m²k
Roof: 0.18
Ground Floors: 0.22
Walls: 0.24
Glazing: 1.73 /0.43
Rooflights: 1.3 / 0.55
Entrance Door: 1.5
Loading Door: 1.49
TENDER
line of brise soleil over
THIS "AS-BUILT" DRAWING IS BASED ON INFORMATION
SUPPLIED TO MICHAEL SPARKS ASSOCIATES BY READIE
CONSTRUCTION AND INCORPORATES INSTRUCTIONS AND
OTHER DESIGN INFORMATION GIVEN TO READIE
CONSTRUCTION DIRECTLY BY OTHERS
AS BUILT