arges™ intersection sweep - 井上スダレ こもれ ... · when the arges™sweep is activated...

Post on 23-Jan-2021

3 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Whelen Engineering Company, Inc.

Arges™ Intersection Sweep

3

The Arges™ Intersection Sweep scenario configures the Argesso that it will automatically sweep left and right increasing emergency responder visibility when approaching intersections.

Scenario Operation

4

• CenCom Core™

• Control Head

• Arges™ with Control Head or

• Arges™ ProFocus™ with Control head

• 2 Virtual Inputs

• 1 Event

• Priority Adjustments

Configuration Requirements

5

Add all required hardware

6

(A). Label the button on the control head Arges™

Sweep and abbreviate it (B). ARSW

7

(A). Add a New virtual Input Name it (B). Arges™ Sweep Virtual Change the Switch type toCycling and the (C). Time for each press to 400 ms.

8

(A). Name Press 1 Arges™ Left and Press 2 Arges Right

9

(A). Select Arges™ Left (B). Select the light sections of the Arges (C). And set the flash pattern to Double Flash 150

10

(A). Select Pan or Tilt (B). Set the Rotation Pan Angle to -65° and the Tilt Angle to 0°

11

(A). Select Arges™ Right (B). Select the light sections of the Arges (C). And set the flash pattern to Double Flash 150

12

(A). Select Pan or Tilt (B). Set the Rotation Pan Angle to 65° and the Tilt Angle to 0°

13

(A). Add a new virtual input name it (B). Arges™ Front Virtual. Set the Switch Type to Variable Timer and set the (C). Time to 600ms.

14

(A). Select the light sections of the Arges™

and set the Action to Turn OFF

15

(A). Select Pan or Tilt (B). Set the Rotation Pan Angle to 0° and the Tilt Angle to 0°

16

(A). Select the Arges™ Sweep Button and (B). Set the Action for the Arges Front Virtual to Set To On

17

(A). Select the Arges™ Sweep Button (B). Select the OFF state (C). On the Inputspage under the Arges Control Head tab set the action for the Home to Set To ON

18

(A). Select the Arges™ Sweep Button (B). Select the OFF state (C). On the Inputspage under the 21 and Slide WCX control head tab set the action for the Arges

Sweep Virtual to Set To OFF

19

(A). Add a new event name it Arges™ Sweep Activation (B). Add 2 conditions 21 and Slide WCX Arges Sweep is ON and, Virtual Inputs Arges Front Virtual is OFF

20

(A). On the Inputs Page under the Virtual Inputs tab set the action for the Arges™ Sweep Virtual to Set To Arges Left

21

(A). Select the Home button on the Arges™ control head (B). Set the Switch Type to Variable Timer and the Time for 2 sec.

22

(A).Select the Home button on the Arges™ control head (B). Select Press 1 (C). On the Inputs page under the 21 and Slide WCX tab set the Arges Sweep Button

to Set To OFF

23

(A). Select the Paddle on the Arges™ control head (B). Select Press 1 Paddle Moving (C). On the Inputs page under the Virtual Inputs tab set action for the Arges Sweep

Virtual to Set To OFF

24

(A). Arrange the Priorities in the following order highest to lowest Paddle Moving, Arges™Front Virtual, Arges Sweep Virtual, Arges Sweep

25

When the Arges™ Sweep is activated the Arges Front Virtual is activated for 600ms. This holds the Arges light off and sets it front facing, so it does not shine in the face of the operator.

Once the Arges Front Virtual counts down to 0 the conditions have been met to activate the Arges Sweep Virtual and the Arges will sweep left to right.

When the Arges Sweep is turned off the Home button on the Arges control head is turned on returning the Arges to the Home position.

Scenario Synopsis

26

27

This Document is Copyright Protected © Copyright

This document contains products that are trademarked by the Whelen Engineering Company, Inc.Reproduction is prohibited. Prices included are for reference only, refer to the Whelen Engineering Automotive Price List and its addenda for current pricing.

Whelen Engineering Company reserves the right to modify its products from those printed in this presentation. Refer to published product bulletins for specifications.

top related