V!net Line up
Remote
Controller
Central
Controller
Wireless RemoteController
Simple Central Controller
Wired RemoteController
AC Smart
Deluxe Central Controller
PC Central Controller
ACP&AC Manager
Accessory
Simple
Standard
Deluxe
PQWRHDF0
PQRCUCA0 (Simple)PQRCFCS0 (Simple for Hotel)
PQRCUSA0
PQRCUDS0 (White)PQRCUDS0B (Blue)PQRCUDS0S (Silver)
PQCSB101S0PQCSB101S0+PQCSC101S0PQCSB101S0+PQCSD130A0
PQCSW502A2
PQCSS513A0
PQCSW320A0E
PQCPA11A0E(Without IO)PQCPB11A0E(With IO)PQCSS520A0E(AC Manager)
& Accessory
&
Acce
ssory
BNU
PQNFB17B0(BACnet)
PQNFB16A1( )
Remote Controller
Central Controller
Accessory
70
72
80
V- n e t & Ac ce s s o r y
PDI, CNU, Remote temperature sensor, Dry contact, Cool/Heat selector
Air guide, Suction grille and canvas, Heat recovery unit, Header, Y branch
(Function controller) (Scheduler)
* Wireless Remote Controller
Simple
Operating mode
Mode change
Room temp
Plasma
Auto swing
Child lock
On_O9 / Fan speed / Mode / Temp.
Cooling / Heating / Fan
√
√
√
√
PQRCUCA0
Simple for Hotel
PQRCFCS0
PQWRHDF0
Features PQRCUCA0
Operating mode
Mode change
Room temp
Plasma
Auto swing
Child lock
On_O9 / Fan speed / Temp.
Impossible
√
√
√
√
Features PQRCFCS0
Features PQWRHDF0
On_O9 / Fan speed / Mode / Temp.
√
√
√
√
Operating mode
Room temperature checking
Chaos swing / Jet cool
On_O9 timer
Sleep mode auto
Main / Sub setting of indoor units
ΔT setting (for Auto Changeover)
* Wired Remote Controller for Air!conditioner
Standard
PQRCUSA0
Features PQRCUSA0
&
Acce
ssory
Remote ControllerOur air conditioning system can be controlled by various types of
remote controllers providing general control to unique function.
Remote Controller Remote Controller
Remote Controller
Remote Controller
* Wired Remote Controller for Heat Recovery Ventilator
Standard
Features PZRCUSB0
On / O9 LEDVentilation mode settingRapid ventilationPower saving ventilationReservationElectric failure compensationChild lock
√√√√
Weekly / Simple Max. 2 hours
√
* Simple Wired Remote Controller
Deluxe
PQRCUDS0 (White)
PQRCUDS0B (Blue)
PQRCUDS0S (Silver)
Features PQRCUDS0, PQRCUDS0B, PQRCUDS0S
On_O9 / Fan speed / Mode / Temp.√√√√√
Weekly / Simple√√
Operating modeTouch screen / LCD bak_lightRoom temp.Fan / Plasma / Swirl / HeaterVane control / Auto swing E.S.P functionReservationTimer functionChild lock
Operating modeOn / O9 LEDRoom temp.Fan / Plasma / Swirl / HeaterVane control / Auto swing / Fan autoE.S.P functionReservationTimer functionChild lockElectric failure compensationWireless remocon receiverMain / Sub setting of indoor unitsΔT setting (For Auto Changeover)2 Controllers to 1 indoor units
On_O9 / Fan speed / Mode / Temp.√√√√√
Weekly / Simple√√
Max. 2 hours√
Optional functionPlasma / Heater / Humidifier
Operating air volumePZRCUSB0
AC SmartFor the mid sized buildings up to 64 or 128 indoor units
can be controlled and monitored by touch screen central
controller. It’s possible to control and monitor the air
conditioning system through web access, anywhere with
computer.
PQCSW320A0E
Combination
RS4850.75mm 2 X 2C
(shield) AC20V
PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)
PMNFP14A0
PHNFP14A0 (Ceiling & Floor, Duct)PSNFP14A0 (CST, RAC)
PHNFP14A0
DC Comm, LineAC Smart
PQCSW320A0E
PQCSB101S0
PQCSC101S0
Function Controller & SchedulerIt is possible to control, monitor and schedule the
operation of indoor units by using these controller
in company with a simple central controller
PQCSB101S0
Simple Central Controller
A central controller for managing small sites Control up to 16 indoor units
Max. no of indoor units
Individual control
Lock function
Mode change
Malfunction indicator
Dimension(mm)
Power(V)
16 indoor units
On_O9 Control
Total / Individual
Cooling / Heating
LED lamp
120 x 120 x 20
DC 10V
Features PQCSB101S0
&
Acce
ssory
* 1 Function controller combined with max. 8 simple central contollers.
Features PQCSB101S0+PQCSC101S0
16 indoor units
On_O9 / Fan speed / Mode / Temp.
Total / Individual
Cooling / Heating / Fan
Error display on LCD
Weekly
(120x120x20)+(120x133x20)
DC 10V
16 indoor units
On_O9 / Fan speed / Mode / Temp.
Total / Individual
Cooling / Heating / Fan
Error display on LCD
-
(120x120x20)+(70x120x14)
DC 10V
Max. no of indoor units
Individual control
Lock function
Mode change
Malfunction indicator
Schedule
Dimension(mm)
Power(V)
PQCSB101S0+PQCSD130A0
Single constant
Single A, MULTI
PQCSB101S0
PQCSD130A0
*128 Indoor unit Expansion Kit: PQCSE440U0*DO Kit : PQNFP00T0
Features
- Accum ulated total po wer consumption indicated
- Accumulated / Current power consumption of each indoor units indicated
- Accumulated power consumption by month indicated
- Max connectable no. of indoor units : 48 indoor units
- 1 PDI per 1 outdoor unit
- Power failure-proof function : Data back up on EEPROM even if power turns o9
- Connectable to PC based central controller
- Simple connection with the re mote mete ring system (RS485 approach)
Combination
PQNUD1S00
Pulse output (1 ,2 , 4 ,6 ,8 ,10W/pulse)AC 200V~240V 50/60Hz
Digital WHM(Local purchase)
AC220V
RS485
Application
Multi Area ManagementThe product specially designed for multi area management.-Central control & monitor Max. 4,096 indoor units & Max.16 ACP
Max. 4,096 Indoor
ACP AC ManagerKorean reference site.
&
Acce
ssory
(Power Distribution Indicator)
This device is an indicator for power consumption
of the multi type air-conditioner used for common
power line.
ACP&AC Manager Through embedded web control function in ACP
one can control and monitor various functions of
air-conditioner such as temperature setting,
schedule, peak power control, etc.
AC Manager is suitable for large site because AC Manager
is the S/W that can control Max. 16 ACP (Max.4,096 indoor units) .
PQCPA11A0E (Without IO)PQCPB11A0E (With IO)
PQCSS520A0E (AC Manager)PQNUD1S00
Features
- Through embedded web control function in BACnet
one can access the airconditioner and external
devices through internet.
- It can control 256 indoor units. ( A/C or Ventilator )
- External devices such as fire alarm, motion
detector can be connected to gateway and their
function can be interlinked with airconditioner
operation.
Combination
BACnetNetwork
BMS system
PHNFP14A0
RS485
Outdoor unit
Lighting control
Other BACnet devicesIndoor unit : Max. 256 units (Air-conditioner & ventilation)Indoor address : 00 ~ FF
Remote checking Utility control
BNU-BAC
PQNFB17B0
BACnet comm. line
Indoor unit
Combination
NetworkBMS system
PHNFP14A0
Lighting control
Other LON devicesIndoor unit : Max. 64 units (Air-conditioner & ventilation)Indoor address : 00 ~ 3F
Remote checking Utility control
RS485
Outdoor unit Indoor unit
BNU-LWPQNFB16A1
LON comm. line
Features
- Connection to using LONTALK protocol and VRS Air-conditioner protocol
- Process ability 64 units( including indoors and ventilators)
Valid address for each unit : 0x00 ~ 0x3F
- Self installation verification function using internet (Web server included) Setting gateway
Diagnosis of communication status on
VRS Air-conditioner network
- Connection to remote total managem ent system (VRS system)
(LON MARK CERTIFICATION VERSION 3.3 FOR VRS)
&
Acce
ssory
PQNFB16A1 PQNFB17B0
BNU-LW Gateway (Building Network Unit- )
Easy interface between BMS and VRS air conditioner
- Independence of BMS under the standard BMS
: Operation system based on LNS ( network service)
- No net work installation needed
- Ver y widely applicable protocol( )
BNU-BAC Gateway (Building Network Unit- BACnet)
Easy interface between BMS and VRS air conditioner
- Independence of BMS under the standard BMS
: Operation system based on BACnet Service.
Simple centralcontroller
or
AC Smart Simple centralcontroller
or
AC Smart
PI485
PI485
PI485
PI485
Controlling Monitoring items
On/O9 command
Operation mode setting
Fan speed setting
Lock setting
Air Tow setting
Set temp. setting
User mode setting (for only ventilator)
On/O9 status report
Operation mode status report
Fan speed status report
Lock status report
Air Tow status report
Set temp. status report
Current space temp. status report
Error status report
Controlling Monitoring items
On/O9 command
Operation mode setting
Fan speed setting
Lock setting
Air Tow setting
Set temp. setting
User mode setting (for only ventilator)
On/O9 status report
Operation mode status report
Fan speed status report
Lock status report
Air Tow status report
Set temp. status report
Current space temp. status report
Error status report
User mode status report(for only ventilator)
User mode status report(for only ventilator)
Mode Change
Heating
Fan Mode
Cooling
Features
- Indoor unit control without central controller
- Select operation mode : Cooling, Heating, Fan mode
- Mode lock for cooling & heating mixing error-proof during the change of season.
Combination
Part description
Without hub
Cross cable
Direct cable
Direct cable
Wiring diagram
Adaptor connection DC 9V (supplied)
RJ45 connectorConnected with the HUBDeluxe central controller
PI485 connectionBUS_A : PI485 A terminal[+]BUS_B : PI485 B terminal[-]
AC/DC adaptor
Wiring diagram
Wire to the c ontrol box in the indoor unit by removing the existing thermistor and connect the extension cable its place.
Cut the extension cable to the appropriate length and connect the screw terminal of the remote sensor.
In the case of wired remote controller installed, set the temperature sensin g slide s/w at MAIN mode.
Connector
Remottemperature sensor
Extension cable
Screw terminal connection
Indoor unit
&
Acce
ssory
PQDSB(A) / PQDSB1 /
Dry Contact module
It is connected between indoor units and external
device, so it can be used for various purpose.
PQNFG14B0
CNU(I-gateway)
CNU converts the ethernet protocol into RS 485
protocol and vice versa.
Used with deluxe and PC based central controllers.
Remote Temperature Sensor
It can help to detect the exact room temperature
at the optimal position.
Model applied to Cassette, Duct type.
Part supplied - Remote temperature sensor
- Cable (15m) - ManualPQRSTA0
Cool/Heat Selector
This switch enables selection of heating, cooling
or fan mode. So it can prevent that cooling & heating
mixing error occurs during the change of season.
PRDSBM
Features
√
√
√
√
√
√
√
√
√
√
Contact point
PQDSA(B) PQDSB1 PQDSBC
Voltage / Non voltage input
On_O9 control
Lock / Unlock
Fan speed setting
Thermo o9
Energy saving
Expected temperature setting
Error Monitoring
Operation monitoring
Power input
1 contact point
AC 220V from outside power source
√
√
√
1 contact point
AC 24V from outside power source
2 contact points
DC 5V&12V from indoor unit PCB
√
√
Suction Grille and Canvas
High Texibility for a wide variety of applications
Indoor unit
Outdoor unit
2
26
26
19
801x218x617
9.52(3/8)
19.05(3/4)
19.05(3/4)
Max. connectable number of indoor units
Max. connectable capacity of indoor units (Per port/unit) kW
Nominal Input cooling kW
heating kW
Net weight kg
Dimensions (WxHxD) mm
Piping Indoor liquid mm(inch)
connections unit gas mm(inch)
Outdoor liquid mm(inch)
unit low pressure mm(inch)
high Pressure mm(inch)
Power supply Ø/V/Hz
3
40
40
20
801x218x617
12.7(1/2)
28.58(1 1/8)
22.2(7/8)
4
40
40
21
801x218x617
12.7(1/2)
28.58(1 1/8)
22.2(7/8)
9.52(3/8)
15.88(5/8)
1/220 ~ 240/50
PRHR020 PRHR030 PRHR040
14.1 / 47
Specifications
Application Dimension
PRHR020(2 Pipe-connection)
PRHR030(3 Pipe-connection)
Combination
Features
- High external static pressure facilitates unit use with Texible ducts of varying lengths. - When using suction panel, unit requires only 270mm of ceiling space. - Blends unobtrusively with any interior decoration.
Models applied to
- Ceiling concealed duct _ Built-in type
PBSGB30
PBSGB40
A B C
910
1188
359
359
56
56
PBSC30
PBSC40
A B C
821
1100
274
274
42~250
42~250
Type
√
√
Capacity (Btu/h)
7kModel
Grille
Canvas
PBSGB30
PBSGB40
PBSC30
PBSC40
√
√
√
√√
√
√
√
9k 12k 15k 18k 24k
√
√
C
A
B
AB
C
&
Acce
ssory
Heat recovery un it
Max. 4 indoor units can be connected by module design.
Due to the autom atic search algorithm for piping
detection, easy installation and e9ectiveness is im proved.
Subcooling cycle in HR unit makes the system
e9iciency maximum.PQAGA
Air Guide
Used to control the direction of air discharge
by outdoor unit.
Converts vertical discharge into horizontal discharge.
PRHR040(4 Pipe-connection)
PBSGB30 / PBSGB40
PBSC30 / PBSC40
Dimension
Auto Clean
4-Way
Air De&ection
Swirl Swing
Auto Restart
Sleep Mode
Auto Operation
Weekly
Program Wired remote
controller only
Two Thermistor
Control Wired remote
controller only
Changable
Panel
Second
Remote Control
NEO Plasma
Air Purifying
System
Jet Cool
Child Lock
Function Wired remote
controller only
Healthy
Dehumidification
Hot Start (Heat pump only)
Soft Dry
Operation Mode
Low Standby
Power
Group Control Wired remote
controller only
Auto Changeover MULTI V SYNC
model only
( )
( )
( )
( )
( )
ModelLow Pressure
Gas PipeLiquid Pipe
(unit:mm)
ARCNB20
High Pressure Gas Pipe
Model Low Pressure Gas Pipe
Liquid Pipe
(unit:mm)
ARCNB20
High Pressure Gas Pipe
ARCNB30
Header for connection of indoor units
Y Branch pipe for connection of outdoor units
Model
4 branchARBL054
7 branchARBL057
4 branchARBL104
Model
7 branchARBL107
10 branchARBL1010
10 branchARBL2010
Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe
(unit:mm) (unit:mm)
Model
ARCNN20
Model
ARCNN20
ARCNN30
Connection of Gas Pipe Connection of Liquid Pipe Connection of Gas Pipe Connection of Liquid Pipe
(unit:mm) (unit:mm)
Model ModelGas Pipe Liquid Pipe Gas Pipe Liquid Pipe
(unit:mm) (unit:mm)
ARBLN01620~under 16.0kW
ARBLN03320~under 33.0kW
ARBLN07120~under 71.0kW
ARBLN1452071.0kW or more~
Model Low Pressure Gas Pipe Liquid Pipe
(unit:mm)
ARBLB01620~under 16.0kW
High Pressure Gas Pipe
ARBLB03320~under 33.0kW
ARBLB07120~under 71.0kW
ARBLB1452071.0kW or more~
Y Branch pipe for connection of indoor units
&