PCXCW14
Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.
@2014-06
Chilled Water SystemSolution Product Catalogue
PRODUCT SYSTEMAir-Cooled
Air Cooled Mini Chiller
Fan Coil Unit
Application
Solution
Cooling & Heating Capacity
R22UAE
R407CUAP
FWE-E
FWC-C
FUD-B
4.0 6.0 8.0 10.0
kW
20.0 25.0 30.0 40.0
Products OverviewContents
01
Application
04
Air Cooled Mini Chiller
13
Solution
Fan Coil Units
Wall Mounted
19
Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly. All specifications are subjected to change by the manufacturer without prior notice.
15.0 50.0
025/030/040/050/060/080/100/120/150
060/080/100/120/150
020/025/030/040/050/055
020/025/030/040/050/055
R410AUAQ
Ceiling Cassette Compact Type (600 x 600)
Ceiling Cassette Type (900 x 900)
Ceiling Cassette Type (900 x 900) With Brushless DC Motor
Ceiling Convertible Type
Ceiling Concealed Type Ducted Blower Type
20 21 22 24
25 27
020/025/030/040/050/060/080/100/120/150
020/025/030/040/050/060/080/100/120/150
Application
AIR COOLED MINI CHILLER APPLICATION EXAMPLES :
CHILLED WATER SYSTEM SOLUTION ADVANTAGES :
Chilled Water System Solution
Advantages
Long Piping Application
Quiet Operation
Less RefrigerantHandling
No Necessity To Use Cooling Towers
Versatility InSystem Coupling
Simple On SiteInstallation
LONG PIPING APPLICATION
Daikin chilled water system has no limitation in piping lengths unlike direct expansion refrigerant system. As long as the water pump head pressure is sufficient to pump the water through the water pipe network, the chiller can be installed far away from the fan coil units. Daikin Mini Chiller is designed to support water operating pressure up to 1000kPa. With such high design pressure, Daikin mini chiller is capable of fulfiling In the case where the Mini Chiller's built in pump head is insufficient to support the overall friction loss, additional pump can be installed to cater for higher pump head requirement.
Private Houses
Hotels
Gym Centres
@Office Rooms Coffee Houses
Restaurant
Universities & Halls
Availablility of cooling only & heatpump
models
Centralized ControlNetwork supports up
to 50 chillers and 120 FCU
Multiple tempratureZone Control
Operation can be managedaccording to zones for different comfort need
Serviceability & ErrorCode Troubleshooting
Easy access for servicing all components. Error codedisplayed on control panel
for troubleshooting purpose
Energy Saving Programmable Timer
Customizable operationschedule of chiller and FCU
based on requirement topromote energy saving
Master/Slave OptionControl based on
network grouping orapplication
Dry Contact BMSCompatibility
Abiblity to be integratedwith BMS
1 2
QUIET OPERATION
Quiet operation due to fan coil unitsand chiller can be placed far away from room
Daikin mini chiller is designed for air cooled application where is no necessity to use the cooling tower especially for small and medium size of chilled water application
NO NECESSITY TO USE COOLING TOWERS
› Less Refrigerant Handling› No Refrigerant Used In Occupied Space› Water As Cooling Medium
Refrigerant is only circulating within the mini chillerunit. Meanwhile, water acts as the cooling medium for FCU. When there is less refrigerant used, the scope of care on refrigerant handling is smaller. In case when there is a leak water is definitely easier to handle in term of process and cost.
LESS REFRIGERANT HANDLING
VERSATILITY IN SYSTEM COUPLING
Chilled water system is designed with versatility in system coupling where there is no limitation in the number of fan coil unit coupling with mini chiller as long as they meetthe designed capacity requirament & water flow rate. System coupling of one to one and one to many configurations
ONE TO ONE
ONE TO MANY
SIMPLE ON SITE INSTALLATION
Refrigarent
The Daikin mini chiller is fully assembled, completewith all necessary components in one unit like waterpump, internal wiring, fully charged with refrigerantand undergo strict testing and quality check before delivery. Only connection to water piping and power supply is required at site.
EASY INSTALLATION AND MAINTENANCE :
FACTORY PRECHARGED REFRIGERANT
Each heat exchanger in the chiller is brazed and tested against leakages through dried air at 30 bars. After that, another process of system vacuuming is done before it is accurately charged with refrigerant to ensure optimum performance. Thus, it saves the hustles of field charging by installers.
Brazed Plate Heat ExchangerPlate type heat exchanger has acompact structure and a high levelof heat exchange efficiency
FILTER DRIER Remove dirt and moisture in the refrigerant circuit.
MULTISTAGE END SUCTION WATER PUMPImpeller and all movable parts in contact with the water are made of stainless steels.
Diaphragm Expansion TankPrevent damage of hydraulic components and cracking of piping due to expansion of hot water in the pipes.
WATER STORAGE TANK Prevent the compressor from switching ON/OFF too frequently during low load conditions such as night time.NOTE: Model UA(E/P)080~150C/CR water tank is offered as an optional device.
SERVICEABILITY & ERROR CODE FOR EASE OF TROUBLESHOOTING
By opening the front panel, one can access and service all the components in the chiller. The chiller is equipped with self diagnosis function which allow the chiller panel to display total of 19 type of faulty occurred in the system by showing different error code on the LCD screen of the panel.
Air Cooled Mini Chiller
Mini chiller can be installed far away from fan coil units
INTEGRATED HYDRONIC COMPONENTSDaikin Mini Chiller is fully integrated and equipped with key hydronic components such as expansion tank, water tank, brazed plate heat exchanger and water circulating pump. As all hydronic components are assembled and tested in the factory, installation of additional component on site can be eliminated.
3 4
Mini ChillerAir Cooled
PARALLEL INSTALLATIONDaikin Mini Chiller provides flexibility in adding capacity for building extension. This can be done by installing the mini chiller in parallel connection.A network of up to 50 chillers is possible to be connected in a system. For ease of controlling and setting, Daikin Mini Chiller panel implement Master and Slave function. This function allows user to monitor all the settings on the slave units at the master unit.
Supported Up To 50 Units Of Chiller
Chiller 0 Chiller 2Chiller 1
Chiller Panel 0(Master)
Chiller Panel 1(Slave)
5 way wire (CM8)ChillerCommunication Bus
SUPERIOR RELIABILITY :
SCROLL COMPRESSORScroll Compressors are used for the units to offer a quieter and more reliable performance over a wide operating temperature range. (Except UAE020C/CR which uses rotary compressor).
For UA(E/P) 030, 040, 050, 060, 080, 100, 120, 150 CR, phase protector is provided to prevent the compressor from rotating in the wrong directions.
State-Of-The-Art Components
CopelandCompliant ®
Scrolls
High EfficiencyMotor
Quiet ShutdownDevice
ANTI-FREEZE PROTECTIONThe chiller unit has several anti-freeze protection features:
1. Built-in heater in BPHEThe BPHE has a strip heater around it to prevent water freezing inside.
2. Anti-Freeze sensorBPHE can avoid the frosting as the anti-freeze sensor will send the signal to cut out the compressor if the water temperature becomes too cold.
3. Water pressure differential switchThis protection feature will ensure there is water flow in pipings when the chiller is in operation. Otherwise, the compressor will cut out immediately.
MICROPROCESSOR CONTROLDaikin chillers are equipped with microprocessor controller that will control and regulate the operation of the unit.
Besides that, the controller that contains the well developed algorithm will provide protection to the chiller by accurately sensing the key temperatures in both the water and refrigerant circuit. Should there be any abnormal reading received by controller, an alarm signal will be sent to chiller panel, followed by protection action plans such as to stop the operation of compressor, condenser fan motor or circulating water pump.
BRAZED PLATE HEAT EXCHANGER (BPHE)The heat exchanger is made of AISI 316 stainless steel plates closely arranged and brazed together to maximize possible heat exchange efficiency.
AISI 316 stainless steel BPHE
SAFETY PROTECTIONThe safety protections provided for the Daikin chiller are:• High & Low Pressure Switches • Anti-Freeze Protection Sensor• Discharge Temperature Sensor• Over Pressure Relief Valve• Water Pressure Differential Switch• Anti-Freeze Heater on BPHE• Compressor Water Pump & Fan Motor Overload Protector
EFFICIENCY AND PERFORMANCE :
CHILLER CONTROL PANELThe chiller panel controller is designed to control the chiller operation. This device allows the user to have customized control for each connected unit.
Each chiller will have a chiller control panel that comes as a standard accessory. At the same time, the chiller control panel is able to be installed remotely through the cable up to a distance of 100 meters. Example, the chiller panel can be installed in a centralized plant control room for the building.
The chiller control panel has been designed taking into consideration of the user friendly and yet versatile control features.
Features:• Whole system configuration.• Unique parameter settings.• Operation status display.• Tracing fault record (offer quick troubleshooting solutions).
• The display is shown in an 8-lines graphical LCD display. There are 8 dedicated keys available in the panel.• Menu selection.• Navigation on the screen.• Modification of the selected value.
5 6
LOAD BALANCING CONTROLFor UA(E/P)080 ~ 150 C/CR both compressors will cut in and cut out depending on their accumulative operating time. This sequencing control feature will ensure no single compressor is overload in operation as well as to ensure longer reliability of compressors.
CAPACITY STEP CONTROLUA(E/P)080 ~ 150 C/CR has been designed with two separate refrigerant circuits, i.e. it has two compressors. By doing so, the unit has part loading capabilities, i.e. 0-50-100% of rated capacity. This will improve the reliability and energy efficiency of the unit, especially during low loading operations.
ANTI CORROSION GOLD ALUMINUM FINGold Aluminum fin is offered as the standard material of the condenser heat exchanger of this series of chiller.
EFFICIENCY AND PERFORMANCE :
Air-Cooled Mini Chiller
This innovative air cooled chiller by Daikin was designed with one purpose in mind, which is to offer cost and energy saving for users.
Model: UAQ 030/040/055 CR
BETTER PERFORMANCE
• Usage of higher efficient R-410A rotary compressors in tandem configuration• Tight tolerances between moving parts resulting in high compressor volumetric efficiency• Minimize mechanical losses• Minimize gas flow losses and turbulence• Optimize compressor oil return
CAPACITY STEP CONTROL
3 steps compressor loading (0%-40%-60%-100%) for UAQ 040 CR & UAQ 050 CR 2 steps compressor loading (0%-50%-100%) for UAQ 030 CR & UAQ 055 CR
ELIMINATION OF WATER TANKCombining the Tandem Compressors technology with the algorithm of the microprocessor control, water tank can be eliminated in most instances.
CHOICES OF SINGLE PHASE AND 3 PHASE POWER SUPPLY CONNECTION• Usage of single phase power supply compressors and circulating water pump.• Offers flexibility to field installation.
water
Ref.1 Ref.2 Ref.1 Ref.1Ref.2
waterwater water
Chiller Panel Comes AsThe Standard Controller
Compatible With Smart Manager
PARALLEL INSTALLATIONA network up to 50 chillers in a system is possible. Control on the operation of the chillers will be done through the microprocessor controller. The external water piping connection can be made either from the left or right side of the unit.
TRUE DUAL CIRCUITS BPHEApply sophisticated technology of true dual circuit
BPHE.
The true dual BPHE puts the secondary circuit (water) in contact with 2 primary circuits (refrigerant). So even if one primary circuit is shut off, each secondary channel is still in contact with a primary channel. These advantages have made the product the natural choice for flexible chillers, climate control applications and high-precision systems food cooling cabinets in supermarkets.
FLEXIBILITY :
7 8
R22 COOLING MODEL
MODEL
NOMINAL COOLING CAPACITY
NORMAL TOTAL INPUT POWER (COOLING)NORMAL RUNNING CURRENT (COOLING) EERREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hWWA
W/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHTNOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSORTYPESTAGE OF CAPACITY CONTROL
PIPINGTYPECONNECTIONHEAD COOLING
mmkPa
TANKCAPACITY / VOLUME MATERIAL
L
UAE020C UAE025C UAE030C UAE040C UAE050C UAE060C
INDO
OR
UN
IT
20,000 24,200 30,000 39,500 48,500 54,0005,860 7,090 8,790 11,580 14,210 15,8302,650 2,680 3,580 4,490 5,080 5,77012.25 12.17 16.41 9.67 9.75 12.012.21 2.65 2.48 2.58 2.80 2.74
1.25 1.80 1.88 2.80 3.15 3.30220-240/1/50 380-415/3/50
CAPILLARY TUBE
R2257 57 58 59 59 59
790 x 1,160 x 460920 x 1,270 x 570
1,140 x 1,160 x 4601,551 x 1,270 x 570
116 123 126 182 189 1960.29 / 1.03 0.33 / 1.20 0.42 / 1.51 0.53 / 1.90 0.67 / 2.40 0.76 / 2.73
ROTARY SCROLL0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%
THREAED25.4
79 92 86 114 90 9222 40
MILD STEEL WITH ZINC
R22 AIR COOLED MINI CHILLER SPECIFICATIONR22 HEATPUMP MODEL
MODEL
NOMINAL COOLING CAPACITY
EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hW
W
W/WW/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT
NOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSOR TYPESTAGE OF CAPACITY CONTROL
PIPING
TYPECONNECTION
HEAD COOLINGmmkPa
TANK CAPACITY / VOLUME MATERIAL
L
UAE020CR UAE025CR UAE030CR UAE040CR UAE050CR UAE060CR
INDO
OR
UN
IT
19,000 23,000 27,500 38,000 44,000 50,0005,570 6,740 8,060 11,140 12,900 14,650
22,000 27,000 35,000 43,000 50,000 55,000
2,600 2,790 3,440 4,390 5,100 5,320
2.20 2.52 3.44 2.63 2.48 2.63
1.43 1.75 1.83 3.50 4.10 4.00220-240/1/50 380-415/3/50
CAPILLARY TUBE
R2257 57 58 59 59 60
790 x 1,160 x 460920 x 1,270 x 570
1,140 x 1,160 x 4601,551 x 1,270 x 570
116 123 128 189 197 2030.26 / 0.93 0.31 / 1.12 0.39 / 1.39 0.56 / 2.00 0.62 / 2.20 0.64 / 2.50
ROTARY SCROLL0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%
THREAED25.4
79 94 92 118 104 110
22 40MILD STEEL WITH ZINC
AA
W
NOMINAL HEATPUMP CAPACITY Btu/hW 6,450 7,910 10,260 12,600 14,650 16,120
2,530 2,670 3,440 4,230 5,190 5,580
11.7811.62
12.1712.70
17.2717.25
9.059.14
9.779.72
12.6011.50
2.48 2.84 3.43 2.87 2.87 3.03
I/s/m3/hrHEATPUMP 0.31 / 1.12 0.38 / 1.38 0.49 / 1.75 0.56 / 2.00 0.62 / 2.20 0.76 / 0.72
HEATPUMP 79 86 73 103 85 87kPa
MODEL
NOMINAL COOLING CAPACITY
EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hW
W
W/WW/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT
NOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSORSTAGE OF CAPACITY CONTROL
PIPING
TYPECONNECTION
HEAD COOLINGmmkPa
INDO
OR
UN
IT
NORMAL RUNNING CURRENT AA
W
NOMINAL HEATPUMP CAPACITY Btu/hW
I/s/m3/hrHEATPUMP
HEATPUMP kPa
UAE080CR80,000
23,45095,000
8,750
2.76
5.00 x 2
63
1,245 x 1,500 x 900
1,452 x 1,732 x 1,032328
27,8408,490
18.4018.90
3.18CAPILLARY TUBE
380-415/3/50R22
95,000
27,840105,000
10,310
2.51
30,77011,100
18.9017.10
2.98
UAE100CR
5.40 + 5.30
63
340
UAE120CR113,000
33,120120,000
12,370
2.74
35,17012,070
26.6026.80
2.86
7.60 x 2
67
480
UAE150CR138,000
40,450132,000
15,020
2.82
38,69014,320
31.4032.20
2.58
6.50 x 2
67
560
1,245 x 1,800 x 1,1501,452 x 2,032 x 1,282
1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20
1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20SCROLL
0 - 100% 0 - 100% 0 - 100% 0 - 100%THREAED
31.75
254 173 188 157229 144 188 157
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
MODEL
NOMINAL COOLING CAPACITY
NORMAL TOTAL INPUT POWER (COOLING)NORMAL RUNNING CURRENT (COOLING) EERREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hWWA
W/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHTNOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSORTYPESTAGE OF CAPACITY CONTROL
PIPINGTYPECONNECTIONHEAD COOLING
mmkPa
INDO
OR
UN
IT
UAE080C65,00024,9108,87017.00 8.87
3.90 x 2380-415/3/50
TXV
R22631,245 x 1,500 x 900
1,452 x 1,732 x 1,032328
0.29 / 1.03SCROLL
0 - 100%THREAED31.75
229
UAE100C95,00027,84010,59018.502.63
4.60 x 2
63
3400.33 / 1.20
0 - 100%
229
UAE120C116,00034,00011,37025.832.99
6.00 x 2380-415/3/50
67
4800.42 / 1.51
0 - 100%
188
1,245 x 1,800 x 1,1501,452 x 2,032 x 1,282
UAE150C138,00040,45014,22031.802.84
7.10 x 2
67
5600.53 / 1.90
0 - 100%
157
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
9 10
HEATPUMPCOOLINGNORMAL TOTAL INPUT POWER
HEATPUMPCOOLING
NORMAL RUNNING CURRENT
HEATPUMPCOOLING
NORMAL TOTAL INPUT POWER
HEATPUMPCOOLING
R407C COOLING MODEL
MODEL
SOUND PRESSURE LEVELUNIT DIMENSIONPACKING
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmmmm
COMPRESSOR
PIPINGTYPE
TANKCAPACITY / VOLUME MATERIAL
L
UAP025C UAP030C UAP040C UAP050C UAP060C
INDO
OR
UN
IT
Btu/h 23,000 26,900 38,500 47,000 50,000NOMINAL COOLING CAPACITYW 6,740 7,880 11,280 13,920 14,650
NORMAL TOTAL INPUT POWER (COOLING) W 2,950 3,770 4,680 5,430 6,040NORMAL RUNNING CURRENT (COOLING) A 13.30 17.41 9.62 10.20 11.28EER W/W 2.29 2.09 2.41 2.56 2.43
REFRIGERANT CHARGE kg 1.72 1.63 3.00 3.30 3.20POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50
REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
REFRIGERANT TYPE R407C57 58 59 59 60
790 x 1,160 x 460920 x 1,270 x 570
1,140 x 1,160 x 4601,551 x 1,270 x 570
UNIT WEIGHT kg 123 126 188 189 196NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 0.31 / 1.11 0.38 / 1.36 0.53 / 1.90 0.64 / 2.30 0.69 / 2.50
TYPE SCROLLSTAGE OF CAPACITY CONTROL 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%
THREAEDCONNECTION mm 25.4HEAD COOLING kPa 94 93 117 93 110
22 40MULTISTAGE END SUCTION
R407C AIR COOLED MINI CHILLER SPECIFICATION
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
MODEL
SOUND PRESSURE LEVELUNIT DIMENSIONPACKING
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmmmm
COMPRESSOR
PIPINGTYPEIN
DOO
R U
NIT
Btu/hNOMINAL COOLING CAPACITY
WNORMAL TOTAL INPUT POWER (COOLING) WNORMAL RUNNING CURRENT (COOLING) AEER W/W
REFRIGERANT CHARGE kgPOWER SOURCE (OUTDOOR) V/Ph/Hz
REFRIGERANT CONTROL (EXPENSION DEVICE)
REFRIGERANT TYPE
UNIT WEIGHT kgNOMINAL WATER FLOW RATE COOLING I/s/m3/hr
TYPESTAGE OF CAPACITY CONTROL
CONNECTION mmHEAD COOLING kPa
UAP080C
80,00023,4509,43018.002.49
3.90 x 2380-415/3/50
TXV
R407C63
1,245 x 1,500 x 9001,452 x 1,732 x 1,032
3401.14 / 4.10
SCROLL0 - 50 - 100%
THREAED31.75
229
UAP100C
90,00026,38011,21019.222.35
3.80 x 2
63
3401.25 / 4.50
229
0 - 50 - 100%
UAP120C
115,00033,73012,17026.502.77
5.60 x 2
67
4801.67 / 6.00
188
0 - 50 - 100%
1,245 x 1,800 x 1,1501,452 x 2,032 x 1,282
UAP150C
137,00040,15014,97033.002.68
6.00 x 2
67
5602.00 / 7.20
157
0 - 50 - 100%
R407C HEATPUMP MODEL
MODEL
NOMINAL COOLING CAPACITY
(COOLING)
(HEATPUMP) EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hW
W
W/WW/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT
NOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSOR TYPESTAGE OF CAPACITY CONTROL
PIPING
TYPECONNECTION
HEADCOOLING
mmkPa
UAP060CR UAP080CR UAP100CR UAP120CR UAP150CR
INDO
OR
UN
IT
50,000 74,000 87,500 110,000 130,00014,650 21,690 32,240 38,10055,000 90,000 96,000 118,000 144,000
5,570 9,350 12,750 16,100
2.33 2.41 2.55 2.40
4.00 3.70 X 2 4.80 + 4.70 5.80 x 2 6.40 x 2380-415/3/50 380-415/3/50
CAPILLARY TUBE
R407C60 63 63 67 67
1,140 x 1,160 x 4601,551 x 1,270 x 570
1,245 x 1,500 x 900 1,245 x 1,800 x 1,150
203 340 340 480 5600.64 / 2.30 1.03 / 3.70 1.25 / 4.50 1.67 / 6.00 1.89 / 6.80
0 - 100% 0 - 50 -100%THREAED
25.4110 263 193 188 172
(COOLING) (HEATPUMP)
AA
W
NOMINAL HEATPUMP CAPACITY Btu/hW 16,120 26,380 28,140 34,500 42,200
6,280 8,990 12,630 15,900
11.6011.50
18.9019.00
27.1026.10
34.4034.80
2.89 2.83 2.71 2.62
I/s/m3/hrHEATPUMP 0.78 / 2.80 1.03 / 3.70 1.25 / 4.50 1.67 / 6.00 1.89 / 6.80
HEATPUMP 87 170 170 188 172
SCROLL
kPa
25,640
11,11011,100
19.0019.102.312.53
1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282
0 - 50 -100% 0 - 50 -100% 0 - 50 -100%
31.75
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
R410A HEATPUMP MODEL
MODEL
NOMINAL COOLING CAPACITY
(COOLING)
(HEATPUMP) EERCOPREFRIGERANT CONTROL (EXPENSION DEVICE)REFRIGERANT CHARGE POWER SOURCE (OUTDOOR)REFRIGERANT TYPE
Btu/hW
W
W/WW/W
kgV/Ph/Hz
SOUND PRESSURE LEVELUNIT DIMENSIONPACKINGUNIT WEIGHT
NOMINAL WATER FLOW RATE
HEIGHT X WIDTH X DEPTHHEIGHT X WIDTH X DEPTH
dBAmm
COOLING
mmkg
I/s/m3/hr
COMPRESSORTYPESTAGE OF CAPACITY CONTROL
PIPING
TYPECONNECTION
HEAD COOLINGmmkPa
TANK CAPACITY / VOLUME MATERIAL
L
UAQ020CR UAQ025CR UAQ030CR UAQ040CR UAQ050CR UAQ055CR
INDO
OR
UN
IT
15,700 21,000 24,800 34,000 41,600 45,0004,600 6,150 7,270 10,000 12,200 13,200
21,500 25,000 32,500 43,000 48,000 55,000
2,590 2,790 3,630 4,650 5,150 5,440
1.76 2.23 1.90 2.00 2.30 2.40
1.20 1.725 2.20 4.30 4.20 4.30220-240/1/50 380-415/3/50
CAPILLARY TUBE
R410A58 59 57 59 59 61
790 x 1,160 x 460920 x 1,270 x 570
1,140 x 1,160 x 4601,551 x 1,270 x 570
128 128 128 195 195 1950.24 / 0.86 0.28 / 1.00 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70
ROTARY TANDEM ROTARY0-100%
THREADED25.4
90 98 93 90 74 70
22 40MILD STEEL WITH ZINC
(COOLING) (HEATPUMP)
AA
W
NOMINAL HEATPUMP CAPACITY Btu/hW 6,300 7,330 9,530 12,600 14,070 16,120
2,620 2,760 3,830 5,000 5,310 5,490
11.7611.93
12.7012.90
16.8816.32
7.447.20
7.907.83
8.188.38
2.43 2.63 2.62 2.71 2.73 2.96
I/s/m3/hrHEATPUMP 0.32 / 1.16 0.35 / 1.25 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70
HEATPUMP 73 90 80 71 64 53
0-100% 0-50-100% 0-40-60-100% 0-50-100%0-40-60-100%
kPa
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICEALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
EVAPORATOR
CONDENSOR
TEMPERATURE
ENTERING
LEAVING
AMBIENT
COOLING
12°C
HEATING
40°C
7°C 45°C
35°C 7°C / 6°C
R410A AIR COOLED MINI CHILLER SPECIFICATION
11 12
NORMAL TOTAL INPUT POWER
NORMAL RUNNING CURRENT
NORMAL TOTAL INPUT POWER
NORMAL RUNNING CURRENT
SMART MANAGER CONTROLLER
Chiller Network BUSFan Coil Network BUS
By adopting the Daikin chilled water system, the comfort in residential and light commercial buildings such as offices, hospital, restaurant, hotel and shopping complex can be controlled and managed from just one point, that is through the Smart Manager.
The Smart Manager is acting as a central command to manage the operation of both the chilled water fan coil units and the chillers.
Besides allowing the user to have customized control for each connected unit, the Smart Manager is also able to manage the overall system operating mode of all units based on the air conditioning system load demand of the building.
SUPPORTED UP TO 50 CHILLERS & 120 FAN COIL UNITSThrough the versatile Smart Manager controller, the operation of each equipments in the Daikin chilled water system connected through the chiller Bus and Daikin own proprietary NIM BUS can be managedand controlled.
NIM
CHILLER CHILLER CHILLER
Up to50 unitsof Chiller
Up to120 unitsof FCUs
AB
AB
CHILLER BUS
NIM BUS
Smart Manager Controller
NIM NIM
FCU FCU FCU WIREDCONTROLLER
CHILLERPANEL
CHILLERPANEL
CHILLERPANEL
Alarm 1(Ch 0)
Comp 1 overload
01/01/00 12.00am
DISPLAY UP TO 46 TYPES OF CHILLER FAULT /ALARM AND 6 TYPES OF FCU FAULT / ALARM
Whenever a fault occurred in either the chiller or fan coil unit, a signal will be sent to Smart Manager and an alarm message willappear on the LCD, showing type of alarm, alarm occured time,date and unit.
This will greatly ease the troubleshooting process and thus reduce the valuable time of service technicians.
As soon as the fault is solved, the alarm will automaticallydissolve from the LCD.
8.00am
9.00am
10.00am
11.00am
12.00am
1.00pm
2.00pm
3.00pm
4.00pm
5.00pm
6.00pm
7.00pm
8.00am
9.00am
10.00am
11.00am
12.00am
1.00pm
2.00pm
3.00pm
4.00pm
5.00pm
6.00pm
7.00pm
Time
FWC
FWK
FWE 2
FWE 1
FWW
Uni
t
The operation of the chiller and each fan coil unit can be preset to operate and tostop at different time schedule and at different day of a week. Taking considerationof the fact that certain rooms in a buildingwill be empty at certain period of the day,setting timer to On and to Off the operationof units in those areas will greatly reducethe energy cost of the building.
At the same time, Smart Manager allowssetting of up to five sets of 7 days programmable operation schedules (2 On/Off timer per day) for each fan coil unit
ENERGY SAVING PROGRAMMABLE TIMER
13 14
If the priority setting is being preset to fan coil unit, the
operating mode of the complete Daikin chilled water system can be synchronized to operate under one same mode. This is achievable through the unique feature called “Threshold Value Setting”
Smart Manager can command chiller operating mode to switch from current operating mode if the threshold value is meet.
Example,In a network of 10 fan coil units that is currently operating in COOL mode and a threshold of 60% was set for COOL mode and threshold of 50% was set for HEAT mode. Should 6 of the fan coil units are requesting for HEAT mode then the threshold for HEAT is crossed. Signal will be sent by Smart Manager to chiller BUS to switch the operating mode of all chillers to HEAT mode. Requirement of users will be met.
FWW
FWE 2FWK
FWC
FWE 1
THRESHOLD VALUE SETTING
• Heat Treshold •
Chiller to operate atHeat Mode
Chiller to operate atCool Mode
0 1 2 3 4 5 6 7 8 9 10
• Cool Treshold •
Depending on the application requirement, Smart Manager controller offers the flexibility to allow user to set the priority on the operation of fan coil unit and Chiller in a complete Daikin chilled water product system.
If priority is set to fan coil unit, the chiller will be forced to OFF if all fan coil units are OFF. If Chiller Priority is being set, all fan coil units will be OFF if chillers are OFF.
PRIORITY SETTING
When there is power failure occurs during operation, Smart Manager Controller will load the last state memory from EEPROM after power On reset.
Besides, extra memory space inside the Smart Manager controller will allow user to view the previous alarm records even though its have been dissolved. This useful information will benefit the service technician to view the history of maintenance record done to the unit.
MEMORY BACKUP (EEPROM),ALARM MEMORY FOR CHILLER AND FCU KEY PARAMETER DISPLAY
For easy serviceability and maintenance, Smart Manager Controller's is able to display the key parameter such as defrost and compressor discharge sensor temperature, water in/out temperature, status of compressor On/Off, Cool/Heat mode water in temperature, etc. Thus, it reduces the cumbersome of requiring the service technicians to physically go to site of chiller installation to do the troubleshooting process.
A Daikin chilled water product system with key parameters that were set by personnel to optimize operating conditions will need to be protected against any unauthorized disturbance or changes. The built in “Password Settings” feature will prevent the losing of key parameter settings in the Smart Manager controller as well as the chiller panel
PASSWORD PROTECTION FOR ADVANCED PARAMETER SETTINGS (CHILLER)
HOLIDAY SETTINGSHoliday 1Holiday 2Holiday 3Holiday 4Holiday 5
Set Holiday 1Month : 1Day : 1Duration : Disable
While designing the Smart Manager, the practical aspects of equipment application were always the key points to be considered. Thus resulting in the creation of “Holiday Setting” feature.
In this feature, users are allowed to set up to 10 holiday timers with each timer can last for duration of 99 days.
During the duration of Holiday Timer set earlier, all fan coil units and chiller will automatically be turned Off.
15 16
HOLIDAY SETTING