apikal view,subcostal view,dan supra sternal view

Post on 26-Jun-2015

341 Views

Category:

Health & Medicine

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

echocardiography

TRANSCRIPT

TUGAS ECHOCARDIOGRAPHYPENGAMBILAN GAMBARAPIKAL

VIEW, SUBCOSTAL VIEW DAN SUPRA STRENAL VIEW

1. AGUNG PRATAMA2. CAHYA SETIYA3. ESAR ARAS SANZABIL4. KHAIRUL HUDDA5. YUDI LESMANA

12/12/12

12/12/12

APICAL VIEWAPIKAL 4 CHAMBERS

* Fungsi diastolik LV

* TAPSEAPIKAL 5 CHAMBERS

*AoVmaxAPIKAL 2 CHAMBERSAPIKAL 3 CHAMBERS

POSISI TRANDUSER POTONGAN APIKAL

Cara pengambilan Cara pengambilan gambar 4 chambergambar 4 chamber

1. Pasien sedikit di terlentangkan 2. Marker di posisikan ke bawah searah jam 3 dari

tubuh pasien

12/12/12

APICAL 4 CHAMBER

12/12/12

Apical 4 Chamber (4 CH)

2 D Menilai gerakan (Motion ) Katup Trikuspid Katup Mitral (MV) Pericard

APIKAL 4 CHAMBER COLOUR DOPPLER

STRUKTUR JANTUNG PADA APIKAL VIEW

PERBEDAAN LV DAN RV

Mitral valve flow dopplerMitral valve flow doppler

MITRAL FLOW

12/12/12

Pengukuran Mitral Flow

Pengukuran doppler mitral flow dilakukan pada gambaran pemotongan 4 ch dimana pada pengukuran ini untuk mendapatkan fungsi diastolik, untuk nilai normal E/A adalah > 1

12/12/12

• Untuk mengetahui fungsi diastolik LV , Sample volume ( sv ) harus diletakan

pada katup mitral• Beri Doppler PW• E/A = harus > 1

• Kalau < 1 adanya gangguan Diastolik

RV FUNGSI(TAPSE)

Pengukuran Fungsi Ventrikel KananPengukuran Fungsi Ventrikel Kanan

- pengukuran Trikuspid annular plain sistolik ekskursion (TAPSE)-Langkah pengambilan yaitu dengan cara potongan 4 Ch kemudian letakkan cursor pada dinding ventrikel kanan – ukur tinggi dari undulasi diding tersebut ( dari gelombang R sampai gelombang T pada gambaran EKG ) nilai normal adalah 1,6

NILAI TAPSENILAI TAPSE

12/12/12

Normal Tapse1,6 cm = 16 mmTapi Kalau ada kebocoran Katup rikuspid Harus > 2 cm = 20 mm

Apikal view , 5 ChambersUntuk mendapat apikal 5 view, Tranduser tilting sedikit ke arah kaudal dari posisi apikal4 chambers

Apical 5 chamber viewApical 5 chamber view

Indicator 4-5 o’Clock

APIKAL 5 CHAMBER

STRUKTUR PADA APIKAL 5 CHAMBER

Apical 5 chamber view

Scan :Tricuspid ValveMitral ValveAortic valve

12/12/12

AoVmax berfungsi untuk melihat atau low output sirkulation

Nilai aoV max > dari 0,8 5 m/s

Prinsip DopplerPrinsip Doppler

Apikal view 2 ChamberRotasi Tranduser 60 derajat counterclockwise

2 D Menilai gerakan

( Motion ) Katup Mitral ( MV

Apikal view 2 Chambers

12/12/12

Untuk melihat Fungsi diastolik LV

E/A = > 1

STRUKTUR JANTUNG PADA 2 CHAMBERS

Apikal View 3 ChambersUntuk mendapat apikal 3 chamber, kembali rotasi 90 derajat counterclockwise

Apikal View 3 Chambers

STRUKTUR JANTUNG PADA 3 CHAMBERS

Sub Costal/ Sub XiphoidTranduser diatas Xiphoid, marker jam 12

Tilting tranduser ke bahu kiri: gambaran long axis

POSISI TRANDUSER POTONGAN SUB COSTAL

12/12/12

Kaki nya di tekuk

STRUKTUR JANTUNG POSISI SUBCOSTAL

Subcostal view Subcostal view long axis

Indicator 3 – 4 o’clock

ptvstv

Subcostal

Subcostal Menilai gerakan ( Motion ) IVC

Subcostal view Subcostal view short axis

Tilting up down

GAMBARAN VENA CAVA INFERIOR

M MODE PADA VENA CAVA INFERIOR

12/12/12

Nilai Mengukur IVCCara mengukur Tranduser diletakan subcostalM MODEDIUKUR 1,5-2 CM DARI PINTU RA

IVC NORMAL = < 1,3 cm

SUPRA STERNALPasien terlentang , kepala tengadah/ hiper ekstensi.Transduser pada angulus Lidovici.Long axis :Posisi Marker ke arah kepala Pasien.Short axis: Rotasi 90 derajat clockwise

gambar55

STRUKTUR JANTUNG SUPRASTERNAL

12/12/12

Untuk Melihat Cortasio Aorta

12/12/12

TERIMA KASIH