RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

1

An Introduction to Device SAR Compliance Testing

An introduction to the basic concepts and techniques in performing a commercial SAR test

Joe Lomako, Principal EngineerRFI-Global Services Ltd.

2

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Presentation Overview – What, Why and How!

• What is SAR Testing• Why do we Test• How do we Test• System Components• Commercial Aspects

3

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

What is SAR Testing?

• Specific Absorption Rate

• A measure of the energy absorption per unit mass

• Textbook definition: “The time derivative of the incremental electromagnetic

energy absorbed by an incremental mass contained in a volume element of

given mass density”

4

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

SAR Equation

ρσ 2ESAR =

•E=Electric Field in•σ=Conductivity of medium•ρ=Density of medium

5

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

The SAR Test

• Automated system

• Robot positioned antenna

• ‘Phantom’ that resembles a human head or body

• Fluid dielectrically equivalent to human tissue

• All details specifically given in Test Standard

6

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Why do we Test?

• In the first instance, Regulatory

• 3.1(a) of the RTTE Directive

• Many standards available

• Main ones of interest

– Europe: EN50360

– FCC: OET Bulletin 65 Supp C

• Other ‘international’ standards in development

7

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Why do we Test?

• Regulatory

• Safety, Public concern

• Stewart report

• Diligence

• Marketing!

8

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

How do we Test?

• Using a commercially available SAR testing system• Other methods

– Laborious– Inaccurate

9

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

SAR Testing Systems

• Several Systems Available• RFI employs the DASY4 system• Comprises of

– Operating System– Robot – Implantable Probes– Phantom– Device positioner– Fluids

Photo courtesy of SPEAG

10

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Data Processing

• “mathematical averaging”• 1g and 10g averaging mass• Different standards ask for different averaging masses• Graphical display of results

11

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

SAR SYSTEM – SOFTWARE

• Operating System

• Computer Automated

• Graphical Interface

• Mathematical Processing of Measured data

12

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Phantoms

• Other Phantoms• Body Mounted• Torso• Hands• Any design

• Photos courtesy of MCL

13

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

A Typical Test

• Placement of the device

14

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

A Typical Test

• Output and inspection of results

15

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Commercial Aspects

• High Cost • Maintenance• UKAS• Quality Systems• Trained and Competent Engineers• Requirement for good technical understanding• Manufacture and disposal or TEM’s

16

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Commercial Aspects - Overheads

• Fluids• Dipole Calibration• Dipole Purchase

– High Q dipole – single frequency• Probe Calibration• Climate Controlled room to maintain temperature and humidity• Support systems – to exercise device during test, GSM test set,

etc

17

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Commercial Aspects - Quality

• A very important factor!• Quality system

– Accredited to ISO 17025– Procedures– Calibration– Records– Inter lab comparison

18

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Commercial Aspects – Common Problems

• Keeping to schedules– Faulty Prototypes– Bespoke or new frequencies– Availability of dipoles or probe calibration

• Can always be provided but at a prohibitive cost– Test cases for devices without product standards

• Maintenance, storage and disposal of liquids• COSHH• Health and safety

19

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Other devices

• Non mobile devices• Not “felt” mandatory• Although in 3.1(a) of the RTTE Directive mention “safety”• New standards will address this

– Product standards– Generic Standards

20

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Other Devices - Examples

• FCC testing – Laptops (3 different host laptops)– PDA’s

• New Standards – namely IEC 62209-2– Devices that are handheld– Body Mounted devices– Wrist mounted devices– Ankle mounted – “tagging”

• Bespoke– Internal medical devices

21

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Device Compliance Testing

• Thank you for listening

• Questions?

22

RFI Global Services LtdEmail: marketing@rfi-global.com Web: www.rfi-global.com

Disclaimer

• The application of technical information varies depending on each user’s particular circumstances. Please ensure that competent technical advice is obtained before acting on the information in this document. No representation is made or warranty given as to the accuracy of the information contained here. RFI does not accept any liability arising from reliance on the information in this document.

• If you would like further information, please contact our Marketing Department:

– Tel: +44 (0) 1256 312000

– Fax: +44 (0) 1256 312001

– E-mail:marketing@rfi-global.com

– Web Site:www.rfi-global.com

top related