aerator mounting riser system mounting simplex … · 28.08.2015 · s ugn al r bk 2000 system 2...

Post on 29-Oct-2019

10 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

RS UGN AL

2

REMOVABLE COVERS ON RISERSWEIGH IN EXCESS OF SEVENTY-FIVEPOUNDS EACH TO PREVENTUNAUTHORIZED ACCESS.

CONTACT THE LOCAL, LICENSEDSINGULAIR DISTRIBUTOR FORELECTRICAL REQUIREMENTS.

3

4

1

CHECK LOCAL REGULATIONS GOVERNINGDETAILS OF EFFLUENT REUSE FOR SPRAYIRRIGATION SUCH AS EFFLUENT QUALITY,SURFACE AREA, PIPING ARRANGEMENT,SPRAY HEAD ANGLE, OPERATING TIMES,ETC.

5

ON DEEPER INSTALLATIONS, PRECASTRISERS MUST BE USED TO EXTENDAERATOR MOUNTING CASTING ANDBIO-KINETIC SYSTEM MOUNTING CASTINGTO GRADE. INSPECTION COVER ONPRETREATMENT CHAMBER MUST BEDEVELOPED TO WITHIN TWELVE INCHES OFGRADE.

GENERAL NOTES:

®

®

U.S.AND

FOREIGNPATENTSPENDING

©MMXV

THIS DRAWING IS THE PROPERTY OF NORWALKWASTEWATER EQUIPMENT COMPANY AND MAY NOTBE COPIED OR REPRODUCED IN WHOLE OR IN PARTWITHOUT WRITTEN PERMISSION FROM NORWECO.

SINGULAIR GREEN TNT - 500WASTEWATER TREATMENT

SYSTEM WITHUV DISINFECTION SYSTEM,

PUMP TANK AND SEPTIC TANK

DRAWN BY

APPROVED BY

REVISION DATE

DATE

SCALE

DRAWING NO.

REVISION

CONTRACTOR'S CERTIFICATION:I (WE) HEREBY CERTIFY THAT THISDRAWING HAS BEEN CHECKED AND ISAPPROVED FOR USE IN CONFORMITYWITH THE CONTRACT DOCUMENTS.

DATE:

NAME:

PROJECT ENGINEER'S APPROVAL:I (WE) HEREBY CERTIFY THAT THISDRAWING HAS BEEN CHECKED AND ISAPPROVED FOR USE IN CONFORMITYWITH THE CONTRACT DOCUMENTS.

DATE:

NAME:

PC-5-7150

NTS

08-28-2015

JMM

MT®

ELECTRICAL CONDUITTO CONTROL PANEL

ACCESS RISER

NOTE: CRITICAL DIMENSIONS ARE INTENTIONALLY LEFT BLANK TO BE FILLED IN PER INDIVIDUAL JOB SITE SPECIFICATIONS.

PUMP TANK

SIMPLEX SUBMERSIBLE HIGHHEAD EFFLUENT PUMP

NOTE: TYPICAL PUMP TANK SHOWN. ACTUAL CONFIGURATION MAY VARY.

UV DISINFECTION UNIT

FORCE MAIN TO RECEIVING ENVIRONMENT

(OPTIONAL)THROTTLING VALVE

ACCESS COVER

EXTENDED AERATIONCHAMBER

4" DIAMETERINLET LINE

PRETREATMENT CHAMBER

ALTERNATEINLET LOCATION

VENTED COVER

SINGULAIR® AERATOR(SEE NOTE 1)

AERATOR MOUNTING RISER

UNDERGROUND POWERSUPPLY ENTRANCE

PRETREATMENT CHAMBER

SUBMERGED TRANSFER PORT

EXTENDED AERATION CHAMBER

SINGULAIR BIO-KINETIC

BIO-KINETIC® SYSTEM

MOUNTING RISERBIO-KINETIC® SYSTEM

DECHLORINATION SYSTEMOPTIONAL BIO-NEUTRALIZER®

CHLORINATION SYSTEMOPTIONAL BLUE CRYSTAL®

APPROVED SEALING DEVICE

AND VENTED COVERAERATOR MOUNTING RISER

BIO-KINETIC® SYSTEM DISCHARGE DETAIL

CAPACITY: 500/600 GALLONS PER DAYNOTE: TOTAL SYSTEM CAPACITY: 2,300 GALLONS RATED

OUTLET END VIEW

SYSTEM DISCHARGE

LOCKING LUGS

ALTERNATE INLETLOCATION

APPROVEDSEALING DEVICE

RECEIVING FLANGE

BIO-KINETIC® SYSTEM LOCKINGLUGS

SECTION A-A

TRANSFER PORTAERATION CHAMBER

BIO-STATIC® SLUDGERETURN

FINAL CLARIFICATIONCHAMBER

RISER AND COVERBIO-KINETIC® SYSTEM MOUNTING

4" DIAMETER EFFLUENT LINE

GASKETED DISCHARGEFLANGE ASSEMBLY

APPROVED SEALING DEVICETO 4" DIAMETER EFFLUENT LINE

GASKETED RISER

CRITICAL DIMENSIONS

ABCDEF

HG

IJKLM

NOPQRS

UT

VWXYZ

3'- 3"3'- 5 1/4"4'- 1 3/4"2'- 5 3/4"10'- 3"0'- 10 1/2"4'- 7 1/2"

0'- 0 3/8"0'- 6"0'- 0 3/8"1'- 2 1/2"4'- 3 1/2"5'- 6"1'- 11"6'- 6"

0'- 3"0'- 1 1/2"1'- 0"0'- 0 3/4"4'- 4"

®

1 SINGULAIR AERATOR, AS TESTED AND ACCEPTED BY NSF, OPERATING 60MINUTES ON / 60 MINUTES OFF

®

(SEE DETAILS)

PLAN VIEW

1000 OR 1200 GALLON SEPTIC TANK

A

T

U

A

H 60°L

N

M

Q

R

P

K

I

C

F

D E

60°

J

S

XG

Y

Z

W

BIO-KINETIC® SYSTEM

A

B

O

rtrox
Approved

RS UGN AL

BK

2000SYSTEM

2

REMOVABLE COVERS ON RISERSWEIGH IN EXCESS OF SEVENTY-FIVEPOUNDS EACH TO PREVENTUNAUTHORIZED ACCESS.

CONTACT THE LOCAL, LICENSEDSINGULAIR DISTRIBUTOR FORELECTRICAL REQUIREMENTS.

3

4

1

CHECK LOCAL REGULATIONS GOVERNINGDETAILS OF EFFLUENT REUSE FOR SPRAYIRRIGATION SUCH AS EFFLUENT QUALITY,SURFACE AREA, PIPING ARRANGEMENT,SPRAY HEAD ANGLE, OPERATING TIMES,ETC.

5

ON DEEPER INSTALLATIONS, PRECASTRISERS MUST BE USED TO EXTENDAERATOR MOUNTING CASTING ANDBIO-KINETIC SYSTEM MOUNTING CASTINGTO GRADE. INSPECTION COVER ONPRETREATMENT CHAMBER MUST BEDEVELOPED TO WITHIN TWELVE INCHES OFGRADE.

GENERAL NOTES:

®

®

U.S.AND

FOREIGNPATENTSPENDING

©MMXV

THIS DRAWING IS THE PROPERTY OF NORWALKWASTEWATER EQUIPMENT COMPANY AND MAY NOTBE COPIED OR REPRODUCED IN WHOLE OR IN PARTWITHOUT WRITTEN PERMISSION FROM NORWECO.

SINGULAIR GREEN TNT - 500WASTEWATER TREATMENT

SYSTEM WITHUV DISINFECTION SYSTEM,PLASTIC PUMP TANK AND

SEPTIC TANK

DRAWN BY

APPROVED BY

REVISION DATE

DATE

SCALE

DRAWING NO.

REVISION

CONTRACTOR'S CERTIFICATION:I (WE) HEREBY CERTIFY THAT THISDRAWING HAS BEEN CHECKED AND ISAPPROVED FOR USE IN CONFORMITYWITH THE CONTRACT DOCUMENTS.

DATE:

NAME:

PROJECT ENGINEER'S APPROVAL:I (WE) HEREBY CERTIFY THAT THISDRAWING HAS BEEN CHECKED AND ISAPPROVED FOR USE IN CONFORMITYWITH THE CONTRACT DOCUMENTS.

DATE:

NAME:

PC-5-7152

NTS

08-28-2015

JMM

MT®

ELECTRICAL CONDUITTO CONTROL PANEL

NOTE: CRITICAL DIMENSIONS ARE INTENTIONALLY LEFT BLANK TO BE FILLED IN PER INDIVIDUAL JOB SITE SPECIFICATIONS.

PUMP TANK

SIMPLEX SUBMERSIBLE HIGHHEAD EFFLUENT PUMP

NOTE: TYPICAL PUMP TANK SHOWN. ACTUAL CONFIGURATION MAY VARY.

UV DISINFECTION UNIT

FORCE MAIN TO RECEIVING ENVIRONMENT

(OPTIONAL)THROTTLING VALVE

ACCESS COVER

EXTENDED AERATIONCHAMBER

4" DIAMETERINLET LINE

PRETREATMENT CHAMBER

ALTERNATEINLET LOCATION

VENTED COVER

SINGULAIR® AERATOR(SEE NOTE 1)

AERATOR MOUNTING RISER

UNDERGROUND POWERSUPPLY ENTRANCE

PRETREATMENT CHAMBER

SUBMERGED TRANSFER PORT

EXTENDED AERATION CHAMBER

SINGULAIR BIO-KINETIC

BIO-KINETIC® SYSTEM

MOUNTING RISERBIO-KINETIC® SYSTEM

DECHLORINATION SYSTEMOPTIONAL BIO-NEUTRALIZER®

CHLORINATION SYSTEMOPTIONAL BLUE CRYSTAL®

APPROVED SEALING DEVICE

AND VENTED COVERAERATOR MOUNTING RISER

BIO-KINETIC® SYSTEM DISCHARGE DETAIL

OUTLET END VIEW

SYSTEM DISCHARGE

LOCKING LUGS

ALTERNATE INLETLOCATION

APPROVEDSEALING DEVICE

RECEIVING FLANGE

BIO-KINETIC® SYSTEM LOCKINGLUGS

SECTION A-A

TRANSFER PORTAERATION CHAMBER

BIO-STATIC® SLUDGERETURN

FINAL CLARIFICATIONCHAMBER

RISER AND COVERBIO-KINETIC® SYSTEM MOUNTING

4" DIAMETER EFFLUENT LINE

GASKETED DISCHARGEFLANGE ASSEMBLY

APPROVED SEALING DEVICETO 4" DIAMETER EFFLUENT LINE

GASKETED RISER

CRITICAL DIMENSIONS

ABCDEF

HG

IJKLM

NOPQRS

UT

VWXYZ

3'- 3"3'- 5 1/4"4'- 1 3/4"2'- 5 3/4"10'- 3"0'- 10 1/2"4'- 7 1/2"

0'- 0 3/8"0'- 6"0'- 0 3/8"1'- 2 1/2"4'- 3 1/2"5'- 6"1'- 11"6'- 6"

0'- 3"0'- 1 1/2"1'- 0"0'- 0 3/4"4'- 4"

®

1 SINGULAIR AERATOR, AS TESTED AND ACCEPTED BY NSF, OPERATING 60MINUTES ON / 60 MINUTES OFF

®

(SEE DETAILS)

PLAN VIEW

1000 OR 1200 GALLON SEPTIC TANK

6'- 7 1/4"

OVERRIDE FLOAT

ALARM FLOAT

ON/OFF FLOAT

A

T

U

A

H 60°L

N

M

Q

R

K

I

C

F

D E

60°

J

S

G N Z

BIO-KINETIC® SYSTEM

A

B

O

CAPACITY: 500/600 GALLONS PER DAYNOTE: TOTAL SYSTEM CAPACITY: 2,300 GALLONS RATED