advantages - packo cooling · milk cooling tank and connected to well or ice water. the milk enters...
Post on 27-Jul-2018
217 Views
Preview:
TRANSCRIPT
Save energy with the
PaCKO eCO-tUBe
s m a r t m i l k c o o l i n g
Advantages concerning energy• Free(!)heatingofwater
• Considerableenergysavingswhenusingwellormainswater!Upto50%lessenergyconsumptionwhencoolingthemilk.
Quality advantages milk • Immediatecoolingofthemilkslowsbacterialgrowth.
• Lowerblendtemperatureinthetankat2ndandsubsequentmilkingsreducesthechanceofbacterialgrowth.
• Noseals,themilkisonlyincontactwithstainlesssteel.Thisavoidspollutionorcontamination.Veryreliableincompari-sonwithplatecoolerorbundletubularcooler.
ThePacko Eco-tube tubular cooler isinstalledinthemilkdeliverylinebetweenmilkingparlourorrobotandthemilkcoolingtankandconnectedtowelloricewater.Themilkentersthetankpre-cooledinthemilkcoolingtank.
Advantages
Technical advantages• Nomaintenance.ThePackoEco-tubeneedsnevertobedismant-
ledforcleaningpurposes,contrarytoaplatecoolerorbundletubularcooler!
• Easycleaning,togetherwiththemilkingmachine.
Financial advantages• Theheatedwellwatercanbeusedasdrinkingwaterforthecattle.
Thisensuresahighermilkyield.Theanimalsliketodrinklukewarmwaterwherebythemilkproductionremainsstable,alsoduringwintertime.Testsonthefarmhaveproventhis.
• Possibilityofinvestmentsubsidy
• Shortreturnoninvestment
• Verylonglifeexpectancy
• Nomaintenancecosts
Packo Inox nvTorhoutsesteenweg154-8210Zedelgem-Belgium
T+3250250610-F+3250200752
Ecooling@packo.com-www.packocooling.com
s m a r t m i l k c o o l i n g •Eco-tube_datasheet_2016_en
ThePackoEco-tubeiste-stedbyNizoFoodResearch(reportno.E2001/21).
Themilkispre-cooledveryrapidlywithwellwatertoatemperatureofabout20°C.Thismeansaconsiderablelowerenergyconsumptionwhencoolingfurtherdownto4°C.Withicewater(instantcooling)themilkiscooledimmediatelybelowthecriticallimitof10°C.Thebacterialgrowthishaltedatonce.
Hint:Alwaysaskforthepossibilityofgettingsubventionsforenvironmentalfriendlysolutions.
ThePackoEco-tubeisthebestsolutionforthepre-coolingofthemilk!
40°C
35°C
30°C
25°C
20°C
15°C
10°C
5°C
0°C
• ••
0,5h 1h 1,5h 2h 2,5h
Three milk cooling systems in a race against time
Direct expansionDirect expansion with heat-exchangerInstant cooling system with heat-exchanger
Subjecttomodifications.Notcontractuallybindingdocument.
100
75
50
25
0
EnergyconsumptionsavingswithEco-tube.
50%
Withoutpre-cooling Eco-tube
DirectexpansionDirectexpansion+pre-coolingIcewatersystem+instantcooling
top related