Acetabulum Roof Reinforcement Plate

© 41medical 2018, All rights reserved, 0000025333 A

The Acetabulum Roof Reinforcement Plate is intended to bridge an acetabular loss of stability and supports cemented acetabular cups in geriatric patients, depending on bone quality. The angle-stable system facilitates good anchorage at the skeleton and an early-functional therapy. The Acetabulum Roof Reinforcement Plate can be combined with an acetabular cup size up to 48 mm.

Indications

• Fractures of the acetabulum due to trauma

• Revision surgery with substantial bone loss in the area of the acetabulum

Contraindications

• Active and / or latent infection

• Allergy to the implanted material (Ti6Al4V)

• Local bone tumours and / or cysts

• Pregnancy

Compatibility

The Acetabulum RRP is only compatible with the following DePuy Synthes articles:

• 03.113.022 Centering Sleeve, percutaneous, for Kirschner Wire Ø 1.6 mm

• 323.027 LCP-Drill Guide 3.5 mm

• 03.113.020 Locking Drill Sleeve 2.8 percutaneous

• 310.284 LCP Drill Bit 2.8 mm

• 319.010 Depth Gauge for Screws

• 311.431 Handle with Quick Coupling

• 511.773 Torque Limiter 1.5 Nm for AO-ASIF-Quick Coupling

• 314.036 Screw Driver Bit Hex 2.5 mm

• 314.116 Screw Driver Bit Stardrive T15

• 314.070 Screw Driver Hex 2.5 mm

• 314.041 Screw Driver Stardrive T15

• 413.010 – 413.095 Locking Screws 3.5 mm, Hex 2.5 mm, TAN / SS (self cutting) L = 10 mm – 95 mm

• 412.101 – 412.131 Locking Screws 3.5 mm, Stardrive T15, TAN / SS (self cutting) L = 10mm – 95 mm

SWISS MADE ENGINEERING

41medical AG • Föhrenweg 7 • CH-2544 BettlachT +41 32 645 41 41 • F +41 32 645 09 59 • info@41medical.com • www.41medical.com

Binding Order: 100.001: Acetabulum RRP Right

100.002: Acetabulum RRP Left

Order per Fax or E-Mail e-mail:+41 32 645 09 59, info@41medical.com

Products are not available for sales in the USA.

Literature

H. Resch et al. Treatment of periprosthetic acetabular frac tures after previous hemi- or total hip arthroplasty, In-troduction of a new implant Oper Orthop Traumatol 2016

H. Resch et al. Treatment of acetabular fractures in older patients introduction of a new implant for primary total hip arthroplasty Arch Orthop Trauma Surg (2017)

41medical AG • Föhrenweg 7 • CH-2544 BettlachT +41 32 645 41 41 • F +41 32 645 09 59 • info@41medical.com • www.41medical.com

SWISS MADE ENGINEERING

© 41medical 2018, All rights reserved, 0000025333 A

top related