ACCT Series – Automatic Cyclic Corrosion Test
Specifications-Details / Models ACCT 1300 HD ACCT 1300 SHD ACCT 1300 OSC
Basic Mode – CCT Honda
Structural Mode – CCT Honda
ASTM B 117
JIS Z 2374
ISO 9227
PV 1210 – VW
CCT I NES M0007 – Nissan
CCT II NES M0007 – Nissan
CCT IV NES M0007 – Nissan
VDA 621-415
ASTM B117
JIS Z 2374
ISO 9227
ISO 11997-2
ASTM D 5894
GMW 14872
Volvo STD 423-0014
Ford CETP: 00-00-L-467
Scania STD 4319
SAE J 2334
Salt Spray (Fog) MODE: Included Included -
Spray Mode: - - Included
Condensation Humidity MODE: Included Included Included
Air Forced (Drying) MODE: Included Included Included
Climatization MODE: Included Included Included
Immersion MODE: Included - -
Low Temperature MODE: Included - -
Purge System Included Included Included
User Interface Platform
Touch Screen Color
2
Trend Plot of Test Parameters on touch screen Included
Lid Safety System Included
UL 508a Compliant Included
Alarm message, recommended maintenance
displayed on touch screen Included
Critical test parameters displayed on one screen Included
20 Programmed Tests Included
Error messages displayed Included
Visual Safety/Alarm System (Touch Screen) Included
Data Acquisition Software
3
Data Acquisition Software: 2 types: PC or SD Card.
2 Types: SD Card (On touch screen) PC (RS 232 or USB)
Pneumatic Lid with Safety Systems
Exterior Dimensions W x D x H 2,480 x 1,250 x 1,645 mm - 97.6” x 49.2” x 64.8”
Interior Dimensions W x D x H 1,300 x 780 x 900 mm - 51.2” x 30.7” x 35.4”
Exterior Dimensions - Lid Open: W x D x H 2,480 x 1,250 x 1,700 mm - 97.6” x 49.2” x 66.9”
Crated Dimensions Approximate W x D x H 2,600 x 1,300 x 1,850 mm - 102.4” x 51.2” x 72.8”
Move-in Dimensions: W x D x H 2,700 x 1,400 x 1,950 mm - 106.3” x 55.1” x 76.8”
Net Weight approximate (Empty) 639 lbs (290 kg)
Gross Weight approximate (crated) 772 lbs (350 kg)
Chamber Volume approximate (w/ lid) 343 gal (1300 l)
4
Ambient Temperature Requirements +63°F - +82°F (+17°C - +28°C)
Ambient Humidity Requirements max. 85% without condensation
Power 208-230V - 50-60Hz - 1 phase
FLA (230V) 32A
Water Quality ASTM D 1193 Type IV
Water Supply 7 to 28 psi (0.5 to 2.0 kgf/cm²)
Water Connection ½ NPT"
Gravity Drain ½ NPT" hose barb fitting
Exhaust Tube 4"
Salt Spray (Fog) MODE:
5
Spray Mode:
Condensation Humidity MODE:
6
Air Forced (Drying) MODE:
Climatization MODE:
7
Immersion MODE:
Low Temperature MODE:
8
Fog Humidity MODE (optional):
Custom chambers upon request
Sheet: Description:No.www.equilamna.com
Date:
Rev.09/06/2015 00ACCTProject:
Specification Sheet
A3