ac airwell product range 2010-11
Post on 30-Mar-2016
305 Views
Preview:
DESCRIPTION
TRANSCRIPT
Product Range
www.airwell.com
2010/2011
AirwellA Strong EuropeanBrand
2
As an internationally oriented company, Airwell Group has pro-
duction facilities, development centres and sales branches
throughout the world. Our plants each specialise in the produc-
tion of individual product groups that to a large extent meet
regional market requirements, and ensure that transport
distances are kept as short as possible. In addition to our own
sales subsidiaries, over 200 distributors in over 80 countries
now trust the quality and service of the Airwell Group.
Worldwide Production Facilities
Six production facilities throughout the world with over 2.500
employees produce between 1.500.000 and 2.000.000 air con-
ditioning units annually. In Europe, AIRWELL is one of the 5
top-ranking brands.
Tillières (France)
Production of: Commercial Condensing Units, Rooftops, Chilled
Water Terminals and Residential Hydronic Systems.
Milan (Italy)
Production of: Air & Water Cooled Chillers, Close Control Units
and Air Cooled Condensing Units.
Shenzhen (China)
Production of: Ductfree Split Units and Water Cooled Conden-
sing Units.
Pons ( France)
Production of: Air Handling Units, Unit Heaters and Modular
Ducted Air Handling Units.
Airwell is the ideal partner for perfect climate solutions,
providing air conditioning and air treatment systems for
all applications. Founded in 1947, Airwell Group is today
one of the global leaders for the manufacture and distri-
bution of high class, environmentally-balanced and reliable
air conditioning systems. Striving for long-term customer
relationships, the Airwell Group provides individual con-
sultancy and professional servicing. Airwell Group is the
ideal partner for perfect climate solutions in residential,
light commercial and industrial applications. Airwell
Group’s products provide comfort, wellbeing and quality
of life, helping to increase people’s productivity. Airwell
Group today has one of the widest product ranges and
distribution networks on the market.
3
Top left: Airwell Group Head
Office near Paris
Top right: Barlassina
Middle left: Shenzhen
Middle right: Tillieres
Bottom: Pons
Pons France
Manufacturing
Airwell Group (Head office: Paris)
Sales & Marketing & Service
France
Italy
Spain
Germany
USA
China
Export
OEM
Tillières France
Milan Italy
Shenzhen China
Shanghai China
Shenzhen China
Tillières France
Milan Italy
Research & Development
AirwellTop Class Air Conditioning Technology
4
Central Air Conditioning Units
With direct expansion and high performance levels, these
appliances are suitable for air conditioning several rooms
centrally.
• Central air conditioning units from 5.2 to 152.8 kW
Close Control and Air Handling Units
Airwell offers a comprehensive range: centralised air-handling
units for indoor and outdoor installation or compact rooftops with
integrated cooling or heat pump on request.
• Ventilation and air conditioning technology up to 100.000 m3/h
• Rooftops from 20 to 220 kW
Chilled Water
Airwell chiller are completely set up on refrigerant and water
side and are ready for immediate use after installation. A com-
plete range of cold water terminals is available.
• Chiller from 4.5 to 1.300 kW
Comfort Room Air Conditioners
The AIRWELL Comfort range aims at smaller and medium-sized
rooms. Perfect for household and commercial use.
• DC Inverters from 1.4 to 9.0 kW
• Fix Speed from 2.1 to 16.9 kW
Multi-Split Air Conditioners
Multi-split air-conditioners are used when you want to cool seve-
ral rooms with only one external unit. There are three basic ver-
sions of multi-split air-conditioners.
• Duo, up to 2 indoor units
• Trio, up to 3 indoor units
• Quattro, up to 4 indoor units
• Cinco, up to 5 indoor units
VRF-FlowLogic
The VRF FlowLogic system is available for applications of up
to 40 indoor units. Whether for residential, light commercial or
industrial use, the compact units provide a cooling capacity of
up to 135 kW. All of the standard units are designed as heat
pumps, and for applications requiring simultaneous cooling
and heating. The outdoor units that are 22 kW and larger are
also available as 3-pipe units.
• Mini-FlowLogic - the compact category
Cooling 11.2 – 15.5 kW or Heating 12.5-17.6 kW
• MFL / EFL – capacity according to size
2-pipe units (cooling and heating) and
3-pipe units MFL/EFL (cooling and heating)
Cooling 22.4 - 135 kW
Heating 25.0 - 150 kW
5
Content
Comfort Room
Air Conditioner 6 - 14
Multisplit Room
Air Conditioner 15 - 17
VRF FlowLogic 18 - 23
Centralized Airconditioning
Systems 25 - 30
Central Air Conditioning 31 - 32
Chiller and Heat Pumps 33 - 45
6
Mobile Range
Portable air-conditioners are the entry-level solution for room air cooling and dehumidification.
Thanks to their castors they can be moved from room to room. There are no installation costs;
all you need is a power socket.
Window Room Air Conditioner
In contrast to split units, compact units combine the indoor part and the outdoor part in one unit.
This is simply installed through the wall or a window.
Single Split Range
An indoor unit is connected to an outdoor unit and a room is thus air conditioned. There are two
types of split-air conditioners: "ON/OFF" units (fix speed units) and inverter units (variable speed
units).This inverter technology sets new standards and fulfills the highest possible demands on
heating and cooling. The inverter system with its variable need-driven compressor guarantees
optimum control of the temperature and the air moisture. This need-driven method of operation
enables an energy saving of up to 40%.
AirwellDC Inverter Air ConditionerRange
AirwellRaumklima -geräteOn/Off
AirwellOn/Off AirConditionerRange
7
MOBILE /MONOBLOCRANGE
AELIAPORTABLE UNITS
2 Cooling models (Heat Pump)From 2,600 to 3,500 W
MAY WINDOW UNITS
5 Cooling models From 2,140 to 6,400 W
AELIA
MAY
2,600 3,500
9A 12A
2,140 2,540 3,280 5,000 6,400
70 90 110 180 220
All performances in watt
8
WALLMOUNTED ON/OFF Range
HAFWALL MOUNTED
5 Models Cooling / Heat PumpFrom 2,100 to 6,770 W
PRIME WALL MOUNTED
5 Models Cooling / Heat PumpFrom 2,050 to 6,770 W
FLO NWALL MOUNTED
2 ModelsCooling / Heat PumpFrom 8,500 to 10,150 W
MODELPRIME
HAFFLO N
2,050 2,760 3,600 55,500 6,770 - -
2,100 2,500 3,500 5,240 6,770 - -
- - - - - 8,200 -
7 9 12 18 24 30 36
All performances in watt
9
MODELPNXO DCIHCD DCIHFD DCIHAD DCIXLF DCI
WALLMOUNTED DCI Range
PNXO DCINVERTER WALL MOUNTED
6 Heat Pump modelsFrom 2,500 to 7,800 W
HCD DCINVERTER WALL MOUNTED
5 Heat Pump modelFrom 2,500 to 6,800 W
HFD DCINVERTERWALL MOUNTED
4 Heat Pump modelsFrom 2,200 to 5,000 W
XLF DCINVERTERWALL MOUNTED
2 Heat Pump modelsFrom 2,500 to 3,500 W
HAD DCINVERTERWALL MOUNTED
5 Heat Pump modelsFrom 2,200 to 6,800 W
- 2,500 3,500 5,000 6,000 6,800 7,800 -
- 2,500 3,500 5,000 6,000 6,800 - -
2,200 2,500 3,500 5,000 - 6,800 - -
- 2,500 3,500 - - - - -
2,200 2,500 3,500 5,000 - - - -
7 9 12 18 21 24 30 36
All performances in watt
10
FLOOR/CEILING ON/OFF Range
FBFFLOOR/CEILING
6 Heat Pump modelsFrom 8,350 W to 13,800 W
SX NFLOOR/CEILING
5 Models Cooling / Heat PumpFrom 2,660 to 8,150 W
CASSETTEON/OFF Range
CKFCASSETTES
7 Models Cooling / Heat PumpFrom 2,750 to 12,350 W
MODELSX N
CKF
MODELFBF
S
2,660 3,520 5,050 6,700 8,150 - -
9 12 18 24 30 36 45
8,350 10,800 12,800 13,800
- - - -
30 36 45 60
2,750 3,250 5,100 6,800 8,300 8,700 12,350
All performances in watt
11
FLOOR/CEILING DCI Range
SX DC INVERTER FLOOR/CEILING
6 Heat Pump modelsFrom 2,500 to 7,500 W
MODEL
SX DCI
FWD DCI
FBD DCI
CK DCI
2,500 3,500 5,000 6,000 6,800 7,500 - -
9 12 18 21 24 30 36 45
CASSETTEDCI Range
CK DCINVERTERCASSETTES
8 Heat Pump modelsFrom 2,500 to 12,100 W
FWB DC INVERTER FLOOR/CEILING
3 Cooling modelsFrom 3,200 to 6,800 W
FBD DC INVERTER FLOOR/CEILING
2 Heat Pump modelsFrom 9,500 to 12,500 W
- 3,200 5,000 - 6,800 - - -
- - - - - - 9,500 12,500
2,500 3,500 5,000 5,800 6,800 8,000 10,000 12,500
All performances in watt
12
DUCTED ON/OFF Range
DUCTEDUNITSDC Inverter
DLS / CDDUCTED
5 ModelsCooling / Heat PumpFrom 5,300 to 16,400 W
DLS / DC DCIINVERTERDUCTED
5 Heat Pump modelsFrom 5,000 to 14,500 W
DLF DCINVERTERDUCTED
5 Heat Pump modelsFrom 2,500 to 7,000 W
MODELDLS
CD
MODELDLF DCI
DLS / CD DCI
9 12 18 21 24 30 37 44 60
9 12 18 21 24 30 36 43 60
- - 5,370 - 6,200 8,600 10,600 12,600 -
- - - - - - - - 16,400
2,500 3,500 5,000 6,100 7,000 - - - -
- - 5,000 6,600 7,100 7,500 10,000 12,500 14,500
All performances in watt
13
COLUMNSPLIT SYSTEMON/OFF Range
SAF COLUMN SPLIT SYSTEM
1 Heat Pump model12,300 W
SAF12,300
45
All performances in watt
WATER CONSOLEUNITSON/OFF Range
CAOWATER CONSOLE
3 Cooling modelsFrom 2,300 to 4,700 W
CAO
2,300 3,000 4,700
230 370 580
14
WATERCOOLEDUNITSON/OFF Range
GCAO NWATER COOLED UNITS
8 Cooling modelsFrom 2,450 to 13,300 W
MODELS
PRIME, HAF
PRIME, HAF, SX, CKF
PRIME, SX, CKF, DLS
PRIME, HAF, SX, CKF, DLS
FLO, SX, CKF, DLS
CKF, DLS
2,450 - - - - - - -
- 2,950 3,850 - - - - -
- - - - - - 10,300 13,300
- - - 5,850 - - - -
- - - - 7,150 - - -
- - - - - 8,600 - -
7 9 12 18 24 30 36 45
Wall mounted PRIME Wall mounted FLO Wall mounted HAF
Floor/Ceiling SXCassette CKFDucted DLS
All performances in watt
15
Unimagined possible combinations
Airwell offers a unique range of multi-split DC inverters. Whether the indoor units are wall-
mounted, ducted, cassette or floor-ceiling, the multi-split outdoor units allow the use of 2, 3, 4
or 5 different indoor units.
In this way the inverter technology sets new standards and fulfills the highest possible demands
on heating and cooling.
The inverter system, with its variable, need-driven compressor guarantees optimum control of
the temperature and the air moisture.
AirwellMultisplit DC On/Off Range
AirwellMultisplit DC InverterRange
16
MULTISPLITSDC Inverter Range 2DUO
DC INVERTERMULTISPLITSFOR 2 INDOOR UNITS
1 Heat Pump modelof 5,000 W
3TRIO DC INVERTERMULTISPLITSFOR 3 INDOOR UNITS
1 Heat Pump modelof 7,200 W
4QUATTRODC INVERTERMULTISPLITSFOR 4 INDOOR UNITS
1 Heat Pump modelof 8,000 W
Ducted DLS DCI
Ducted DLF DCI
Floor/Ceiling SX DCI Wall mounted XLF DCI Cassette CK DCI
Wall mounted PNXO DCIWall mounted HCD DCI
17
MULTISPLITSDC Inverter Range
MULTISPLITSDC Inverter Range
3TRIO DAKOTA DC INVERTERMULTISPLITSFOR 3 INDOOR UNITS
1 Heat Pump modelof 5,200 W
2DUO DAKOTA DC INVERTERMULTISPLITSFOR 2 INDOOR UNITS
1 Heat Pump modelof 3,900 W
5CINCODC INVERTERMULTISPLITSFOR 5 INDOOR UNITS
1 Heat Pump modelof 11,000 W
DUO, TRIO, QUATTRO, CINCO
DCI
DUO DAKOTATRIO DAKOTA
DCI
5,000 7,200 8,000 11,000
DUO DCI TRIO DCI QUATTRO DCI CINCO DCI
3,900 5,200 - -
DUO DAKOTA DCI TRIO DAKOTA DCI
All performances in watt
Ducted DLS DCI Ducted DLF DCIFloor/Ceiling SX DCI Wall mounted XLF DCI
Wall mounted HFD DCI
Cassette CK DCI
Wall mounted PNXO DCIWall mounted HCD DCI Wall mounted HAD DCI
18
AirwellVRF FlowLogic
VRF FlowLogic
With Airwell FlowLogic you are always making the right choice. Whether for residential, light
commercial or industrial use, the compact units provide a cooling capacity of up to 135 kW, with
up to 40 indoor units. All of the standard units are designed as heat pumps. For applica tions
requiring simultaneous cooling and heating, the outdoor units that are 22 kW and larger are also
available as 3-pipe units. The possible applications for Airwell FlowLogic are diverse: offices,
administration areas and conference rooms, sales and commercial areas, living spaces and
hotels.
19
FLOWLOGICINDOOR UNITS:Cassettes
ST-NKFL 4-WAY-CASSETTE
9 ModelsCooling: 2.2 – 16.0 kWHeating: 2.5 – 18.0 kW
ST-NK2FL 2-WAY-CASSETTE
6 ModelsCooling: 2.2 – 7.3 kWHeating: 2.5 – 8.0 kW
ST-NK1FL 1-WAY-CASSETTE
5 ModelsCooling: 2.8 – 7.3 kWHeating: 3.2 – 8.0 kW
MODEL
ST-NKFL
ST-NK2FL
ST-NK1FL
2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) 7.3 (8.0) 10.6 (11.4) 14.0 (16.0) 16.0 (18.0)
2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) 7.3 (8.0) - - -
- 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) 7.3 (8.0) - - -
7 9 12 16 18 24 36 48 60
Values in brackets = rated heating capacity All performances in kilowatt
20
FLOWLOGICINDOOR UNITS:Wall Mouted
ST-NWFLWALL MOUNTED
6 ModelsCooling: 2.2 – 7.3 kWHeating: 2.5 – 8.0 kW
XAVWALL MOUNTED
3 ModelsCooling: 2.2 – 3.6 kWHeating: 2.5 – 4.2 kW
FLOWLOGICINDOOR UNITS:Ducted
ST-NDSLPDUCTED
6 ModelsCooling: 2.2 – 6.4 kWHeating: 2.5 – 7.0 kW
ST-NDLPDUCTED
8 ModelsCooling: 2.2 – 14.0 kWHeating: 2.5 – 16.0 kW
ST-NDHPDUCTED
5 ModelsCooling: 7.3 – 28.0 kWHeating: 8.0 – 31.5 kW
Flat Panel
Standard pressure
High pressure
21
FLOWLOGICINDOOR UNITS:Ceiling Units
ST-NPFL CEILING UNIT
6 ModelsCooling: 3.6 – 14.0 kWHeating: 4.2 – 16.0 kW
MODEL
ST-NWFL
XAV
ST-NDSLP
ST-NDLP
ST-NDHP
ST-NPFL
ST-NFFL
2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) - 7.3 (8.0) - - - -
2.2 (2.5) 2.8 (3.2) 3.6 (4.2) - - - - - - - -
2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 7.1 (6.3) - 7.3 (8.0) - - - -
2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) 6.4 (7.0) - - - - -
2.2 (2.5) 2.8 (3.2) 3.6 (4.0) 4.5 (5.0) 5.6 (6.3) - 7.3 (8.0) 10.6 (11.4) 14.0 (16.0) - -
- - 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) - 7.3 (8.0) 10.6 (11.4) 14.0 (16.0) - -
- - - - - - 7.3 (8.0) 10.6 (11.4) 14.0 (16.0) 22.4 (25.0) 28.0 (31.5)
7 9 12 16 18 22 24 36 48 76 96
FLOWLOGICINDOOR UNITS:Fan Coil Units
ST-NFFLFAN COIL UNIT
6 ModelsCooling: 2.2 – 7.1 kWHeating: 2.5 – 8.0 kW
Values in brackets = rated heating capacity All performances in kilowatt
22
MVIINDOOR UNITS
CKV/KXV CASSETTE
8 ModelsCooling: 2.2 – 11.0 kWHeating: 2.5 – 12.5 kW
SXV FLOOR/CEILING UNIT
7 ModelsCooling: 2.8 – 7.1 kWHeating: 2.5 – 8.0 kW
DLV/DSV DUCTED
7 ModelsCooling: 2.2 – 11.0 kWHeating: 2.5 – 12.5 kW
PNV WALL MOUNTED
6 ModelsCooling: 2.2 – 6.3 kWHeating: 2.5 – 7.0 kW
MODEL
CKV
SXV
DLV/DSV
PNV
2.2 2.8 3.6 4.5 5.6 6.3 7.1 9.0 11.0
2.2 2.8 3.6 4.5 5.6 6.3 7.1 - -
2.2 2.8 3.6 4.5 5.6 6.3 7.1 9.0 11.0
2.2 2.8 3.6 4.5 5.6 6.3 - - -
007 009 012 015 018 021 024 030 036
All performances in kilowatt
23
MFL40/50/60 HMINI-FOWLOGIC
3 ModelsCooling: 11.2 – 15.5 kWHeating: 12.5 – 17.6 kW
MFL 80-480OUTDOOR UNIT (2 PIPE)
21 ModelsCooling: 22.4 – 135.0 kWHeating: 25.0 – 150.0 kW
EFL 80-480OUTDOOR UNIT (2 PIPE)
21 ModelsCooling: 22.4 – 135.0 kWHeating: 25.0 – 150.0 kW
FLOWLOGICOUTDOORUNITS
24
MVIOUTDOORUNITS
YAVVRF OUTDOOR UNIT
3 ModelsCooling: 11.2 – 15.5 kWHeating: 12.5 – 18.0 kW
MFL/EFL 40/50/60
MFL/EFL 80-160
MFL/EFL 180-320
MFL/EFL 340-480
11.2 (12.5) 14.0 (16.0) 15.5 (17.6)
40 H 50 H 60 H
YAV11.2 (12.5) 14.0 (16.0) 15.5 (18.0)
112 140 160
22.4 (25.0) 28.0 (31.5) 33.5 (37.5) 40.0 (45.0) 45.0 (50.0)
80 100 120 140 160
50.4 (56.0) 56.0 (63.0) 61.5 (69.0) 68.0 (76.5) 73.0 (81.5) 78.5 (87.5) 85.0 (95.0) 90.0 (100.0)
180 200 220 240 260 280 300 320
96 (108) 101 (113) 107 (119) 113 (127) 118 (132) 124 (138) 130 (145) 135 (150)
340 360 380 400 420 440 460 480
Values in brackets = rated heating capacity All performances in kilowatt
25
AirwellCentralised Air Conditioning Systems
Close Controls data processing units are well suited for precision air conditioning of rooms
and buildings when it is absolutely necessary to dissipate only sensible heat.
Monobloc units house all components together in a single unit, allowing installation and ope-
rating costs to be minimised.
Close Controls and ducted split terminal units together with the appropriate condenser units,
allow for optimal climate control even in difficult conditions.
The ventilation and air conditioning technology, with a comprehensive range of rooftops
and centralised air-handling units, provides the right solution for many applications such as shop-
ping centres, furniture stores, exhibition halls, cinemas and production facilities.
26
AIR COOLEDSPLIT SYSTEMS
DK/DNAIR COOLED SPLIT UNIT
12 ModelsCooling / Heat PumpFrom 12.0 to 83.0 kW
Condensing Units with Axial Fan
EHN/CHNAIR COOLED SPLIT UNIT
9 ModelsCooling / Heat PumpFrom 6.0 to 29.2 kW
Condensing unit with radial fan
EVN/CVNAIR COOLED SPLIT UNIT
11 ModelsCooling / Heat PumpFrom 19.4 to 85.4 kW
Condensing unit with radial fan
EHN/CHN
EVN/CVN
6 7.5 9.7 12.1 15.7 19.5 21.9 24.6 29.2
064 084 104 124 164 204 224 254 304
19.4 24.5 29.1 32.3 37.7 42.7 49.1 58.1 64.6 75.4 85.4
204 254 304 354 384 454 504 604 654 754 904
DK/DN12.0 14.5 17.5 19.1 21.0 28.5 36.0 37.5 44.0 56.0 69.1 83.0
125 155 185 205 255 305 405M 405 505 605 755 905
All performances in kilowatt
27
CONDENSINGUNITS
CDNCONDENSING UNITS
8 Cooling modelsFrom 18.6 to 83.0 kW
In combination withany evaporator
WATER COOLEDAND DX DUCTEDINDOOR UNITS
HEATING UNITS WESTHERMHEATING UNIT
7 Models
Cooling / Heat PumpFrom 7.5 to 179 kW
HRWWATER SOURCE HEAT PUMP
13 Models
Cooling / Heat PumpFrom 1.94 to 29.9 kW
CDN18.6 27.8 36.0 35.1 44.4 55.6 69.1 83.0
205 305 405M 405 505 605 705 905
WESTHERM7.5-22.1 17.3-47.4 23.7-66.0 31.0-87.1 41.6-116.0 57.0-155.0 62.7-179.0
35 45 50 55 65 70 110
HRW
1.94 2.34 2.97 5.28 5.92 8.69 10.14 11.37 12.97 14.34 17.2 21.8 29.9
7 9 12 19 24 30 36 42 48 60 72 96 120
All performances in kilowatt
28
MONOBLOC-UNITS
HANMONOBLOC
7 ModelsHeat PumpFrom 9.8 to 31.0 kW
Condensing Unit wit Axial Fan for outdoor installation
AHNMONOBLOC
9 ModelsCooling / Heat PumpFrom 6.0 to 29.2 kW
Condensing Unit with Radial Fan for indoor installation
AVNMONOBLOC
11 ModelsCooling / Heat PumpFrom 19.4 to 85.4 kW
Condensing Unit with Radial Fan for indoor installation
AVN
19.4 24.5 29.1 32.3 37.7 42.7 49.1 58.1 64.6 75.4 85.4
204 254 304 354 384 454 504 604 654 754 904
HAN
AHN
9.8 13.0 14.5 16.8 18.9 25.4 31.0
6.0 7.5 9.7 12.1 15.7 19.5 21.9 24.6 29.2
10 13 15 17 19 25 31
064 084 104 124 164 204 224 254 304
All performances in kilowatt
29
CLOSE CONTROL
CWCLOSE CONTROLSCOLD WATER
12 Cooling modelsFrom 15.1 to 152.8 kW
CDCLOSE CONTROLSAIR COOLED / WATER COOLED
10 Cooling modelsFrom 10.6 to 32.1 kW
MDCLOSE CONTROLSAIR COOLED / WATER COOLED
14 Cooling modelsFrom 20.5 to 102.9 kW
CW
15.1 25.8 35.5 49.8 57.8 39.4 49.2 60.8 83.0 94.8 110.8 152.8
021 031 041 051 061 042 052 062 082 102 112 152
CD
10.6 13.4 17.0 21.2 23.5 29.4 32.9 21.6 25.9 32.1
031 041 051 061 071 091 101 072 082 102
MD
20.5 26.4 31.4 36.1 45.1 55.1 29.0 35.2 47.2 52.6 63.9 69.7 88.8 102.9
061 071 091 101 131 151 082 102 132 152 182 202 262 302
All performances in kilowatt
30
VERTICAL CABINETS
X-ARVERTICAL AIR CABINETS
6 Cooling modelsFrom 9.7 to 55.0 kW
X-AOVERTICALWATER CABINETS
6 Cooling modelsFrom 8.0 to 45.7 kW
- 9.7 16.2 19.8 29.0 38.9 55.0
8.0 11.7 18.0 23.0 32.4 45.7 -
CX 25 1100 1900 2450 3250 4650 6450MODELX-AR
X-AOAll performances in kilowatt
31
ROOFTOPUNITS
RT ROOFT@IRROOFTOP WEATHER PROOF COMPACT UNIT
7 ModelsCooling: 41.5 – 108.4 kWHeating: 41.0 – 106.1 kW
Galvanised, coated construction, 25 mm insulation
RTC ROOFTECHROOFTOP WEATHER PROOF COMPACT UNIT
7 ModelsCooling: 101 – 221 kWHeating: 97.4 – 220 kW
Aluminium construction, double-layer, 50 mm insulationgas heating, heat recovery, 2-3 flap system
MODELRT ROOFT@IR
RTC ROOFTECH
41.5 50.9 59.8 67.7 84.9 96.6 108.4 - - - - - -
- - - - - 101.0 - 115.2 135.4 158.1 176.4 198.8 221.1
40 50 60 70 80 100 110 120 140 160 180 200 220
All performances in kilowatt
RT4DROOFTOP WEATHER PROOF COMPACT UNIT
10 ModelsCooling: 16.2 – 207.8 kWHeating: 14.4 – 183.2 kW
Aluminium construction, double-layer 50 mm, gas heating,thermo-dynamic heat recovery, 4 flap system
RT4D
16.2 29.2 33.4 50.4 58.4 83.9 103.9 150.7 167.5 207.8
20 40 60 80 100 140 180 240 280 380
32
TEMP@IRCENTRALIZED AIR HANDLING UNIT FOR INDOOR & OUTDOORINSTALLATION
10 ModelsFrom 500 to 30,000 m3/h
Panel thickness 50 mm with base frameCertified in accordance with DIN EN 1888
@IRSTEELCENTRALIZED AIR HANDLING UNIT FOR INDOOR & OUTDOORINSTALLATION
15 ModelsFrom 1,500 to 100,000 m3/h
Panel thickness 25-50 mm. Also available without base framedepending on size. Certified in accordance with DIN EN 1886
TEMP@IR
@IRSTEEL
1,500 – 30,000 m3/h
1,500 – 110,000 m3/h
20 40 60 90 120 160 200 240 300 360
20 40 60 90 120 160 200 240 300 360 400 500 700 900 1000
AIR HANDLINGUNITS
33
AirwellChilled Water Terminal Unit, Residential HeatPumps and Chiller
More and more customers are opt for water-cooled air conditioners, even in the residencial
sector. The AIRWELL water-cooled range is made to perfectly suit the various customer require -
ments. It offers you Airwell water chillers that are completely set up on refrigerant and water
side and can be delivered at short notice. The water-cooled room air conditioners are known for
their wide variety, whether it is a floor/ceiling, ducted, wall-mounted or cassette design.
Our technicians and engineers will be pleased to support you in planning and designing of
larger facilities.
34
CASSETTEUNITS
K-OGCASSETTE UNIT
5 ModelsCooling / HeatingFrom 2.2 to 10.4 kW
KCO COANDACASSETTE UNIT
3 Models Cooling / HeatingFrom 0.93 to 4.34 kW
WALL MOUNTEDUNITS
XLM-OGWALL MOUNTED UNIT
3 ModelsCooling / HeatingFrom 1.85 to 3.66 kW
INDUCTIONUNITS
AQU@BEAMDUCTED UNIT
20 Models Cooling / HeatingFrom 58 to 1167 W
MODELXLM OG
K-OG
1.85 kW 2.2 kW - 3.6 kW - -
- 2.2 kW (1) 3.5 kW (1) 5.0 kW (1) 6.44 kW (1) 10.2 kW (1)
7 9 12 18 30 45
58-334 W 70-362 W 77-401 W 85-468 W 97-533 W 105-601 W
1W-12 1W-15 1W-18 1W-21 1W-24 1W-27
52-356 W 62-391 W 77-444 W 92-481 W 102-533 W 113-623 W 129-711 W 139-800 W 169-889 W
2W-06 2W-09 2W-12 2W-15 2W-18 2W-21 2W-24 2W-27 2W-30
49-517 W 76-822 W 76-822 W 93-1167 W 93-1167 W
4W-06 4W1-12 4W2-12 4W1-18 4W2-18
KCO
AQU@BEAM
1.74 kW (2) 2.87 kW (2) 4.34 kW (2)
60 90 120
(1) 2-pipe heat exchanger (2) Highest fan speed
35
DUCTED UNITS
VH2NDUCTED UNIT
9 Models Cooling / HeatingFrom 0.36 to 27.72 kW
VHFDUCTED UNIT
4 ModelsCooling / HeatingFrom 3142 to 9498 W
VPXDUCTED UNIT
4 Models Cooling / HeatingFrom 6700 to 5737 W
VH2N2.85 kW (1) (2) 5.31 kW (1) (2) 7.48 kW (1) (2) 9.82 kW (1) (2) 15.05 kW(1) (2) 18.69 kW(1) (2) 21.32 kW(1) (2) 24.07 kW(1) (2) 27.72 kW(1) (2)
03 05 07 10 15 18 21 24 27
(1) 2-pipe heat exchanger (2) Highest fan speed
WESPAKDUCTED UNIT
6 ModelsCooling 3.0 – 45.0 kWHeating 9.0 – 57.0 kW
WESPAK3 kw 6 kW 12 kW 26 kW 36 kW 45 kW
1.39 2.69 3.99 4.05 5.05 6.05
VHF543-3142 W 1490-4336 W 3421-7361 W 5061-9498 W
01 05+ 10 12
VPX1400-6007 W 1400-6007 W 1400-6007 W 1260-5737 W
Config. I Config. J Config. L CONFIG. U
36
FAN COILUNITS
AQU@FAN IIAWC-A
8 ModelsCooling / HeatingFrom 1.1 to 10.74 kW
AQU@FAN IIAHC-A
8 Models Cooling / HeatingFrom 1.1 to 10.74 kW
AQU@FAN IIAWN-A
9 Models Cooling / HeatingFrom 1.1 to 10.74 kW
AQU@FAN IIAHN-A
9 ModelsCooling / HeatingFrom 1.1 to 10.74 kW
MODELAWC-A/AHC-A
AWN-A/AHN-A
- 2.01 2.44 3.46 5.01 5.73 - 9.04 10.74
1.14 2.01 2.44 3.46 5.01 5.73 - 9.04 10.74
1030 2030 3030 4030 5030 6030 7030 8030 9030
2-pipe heat exchanger (3 rows) - Low fan speed - All performances in kilowatt - Chilled water temp. 7/12°C, Room temp. 27°C/48% rh
37
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600
MQH
AQL/AQH
AQVL/AQVH
VLS/VLH
AQTL/AQTH
SLS R134a
5.4-17.8 kW
40 -75.8 kW
84-137 kW
136-308 kW
289-626 kW
293-1646 kW
CWP
RWC/RWR
SWS/SWR
7.6-131.7 kW
160.8-312.3 kW
271.8-1,118 kW
AQVC
VLC
AQTC
92-151 kW
154-347 kW
326-706 kW
AQCL/AQCH 24.9-125 kW
AIR COOLED CHILLER WITH RADIAL FAN
WATER COOLED CHILLER
AIR COOLER CONDENSING UNITS
kW
AIR COOLED CHILLER WITH AXIAL FAN
SPH/SPH-R
PAC+/PAC+R
PAC HT
8-14 kW
8-14 kW
6.5-8.9 kW
RESIDENTIAL HEAT PUMP
POWERFUL WATER-COOLED RANGE FROM 5.6 KW TO 1.6 MW!
ALL CHILLER ARE EUROVENT CERTIFIED!
38
RESIDENTIALHEAT PUMP
SPH/SPH-RSPLIT AIR TO WATERHEAT PUMPSREVERSIBLE/RELIEF OFBOILER
3 Models Cooling / Heat PumpFrom 8.1 to 14.1 kW
PAC+/PAC+RAIR/WATER HEAT PUMPS
3 Models Cooling / Heat PumpFrom 8.1 to 14 kW
PAC HTHIGH TEMPERATURE (UPTO 65°C) HEAT PUMPSWITH PRODUCTION OFSANITARY HOT WATER
3 Heat Pump modelsFrom 12 to 17.9 kW
MODELSPH / SPH-R 8.1 11.2 14.1
8 10 12
MODELPAC+ / PAC +R 8.1 11.2 14.0
8 10 12
MODELPAC HT 12 14.3 17.9
12-6 14-7 18-9
All performances in kilowattHeating capacity for air temperature 7°C, water temperature 30/35°C
Dual compressor heating capacity / exterior ambient temperature of 7°C / water system 40/50°C
39
AQL/AQHAIR-COOLED WATERCHILLERSAXIAL FAN
10 Models Cooling / Heat PumpFrom 19 to 76 kW
AQVL/AQVCAIR-COOLED WATERCHILLERAXIAL FAN
6 Models Cooling / Heat PumpFrom 83.6 to 137.1 kW
AIR-COOLEDWATERCHILLER
MQHAIR-COOLED WATERCHILLERSAXIAL FAN
7 Models Cooling / Heat PumpFrom 5.4 to 17.8 kW
MODELMQH 5.4 7.6 9.7 12.1 13.1 15.1 17.8
6 8 10 12 14 16 18
MODELAQL/AQH 19.1 25 31 36 40 44 51 60 68 76
20 25 30 35 40 45 50 60 65 75
MODELAQVL/AQVH 83.6 93.7 103 111 122 137
85 95 105 115 125 140
All performances in kilowatt
40
VLS/VLHAIRCOOLED WATERCHILLER WITH SCROLL COMPRESSOR
8 Models Cooling / Heat PumpFrom 136 to 308 kW
AQTL/AQTHAIRCOOLED WATERCHILLER WITH SCROLL COMPRESSOR
7 Cooling modelsFrom 289 to 621 kW
AIR-COOLEDWATERCHILLER
SLSAIRCOOLED WATERCHILLER WITH SCREW COMPRESSOR
23 Cooling modelsFrom 293 to 1646 kW
R-134a
41
AQCL/AQCHAIRCOOLED WATER CHILLER WITHRADIAL FAN
11 Models Cooling / Heat PumpFrom 24.9 to 125 kW
MODELVLS/VLH 136 154 176 199 229 251 280 308
524 604 704 804 904 1004 1104 1204
MODELAQTL/AQTH 289 336 362 407 473 553 626
1206 1355 1506 1656 1806 2106 2406
MODELSLS 293.0 326.2 365.6 410.6 455.5 480.5 513.6 546.8 620.3 660.0 718.6 758.8
1402 1602 1802 1902 2002 2202 2502 2702 3002 3202 3402 3602
823.3 908.8 962.4 1027.2 1093.6 1167.1 1240.6 1320.0 1437.2 1517.2 1646.6
4202 4602 4802 5004 5404 5704 6004 6404 6804 7204 8404
MODELAQCL/AQCH 24.9 28.8 33.7 39.6 46.4 56.3 67.5 76.5 99 114 125
25 30 35 40 50 60 70 80 100 120 130
All performances in kilowatt
42
WATERCOOLED WATERCHILLER
CWPWATER COOLED WATER CHILLER WITH SCROLL COMPRESSOR
13 Models Cooling / Heat PumpFrom 7.6 to 136 kW
RWC/RWR*WATER COOLED WATER CHILLER WITH SCROLL COMPRESSOR
6 Cooling modelsFrom 160.8 to 312.3 kW
*RWR = for external condensers. Split design
43
*SWR = for external condensers
SWS/SWR*WATER COOLED WATER CHILLER WITH SCREW COMPRESSOR
15 Cooling modelsFrom 271.8 to 1,118.2 kW
R-134a
MODELRWC/RWR 160.8 186.5 210.6 263.6 283.7 312.3
170 200 240 280 320 360
MODELSWS/SWR R134a 271.8 362.4 440 529.3 564.7 600 639.2 678.4 716 784.4 841.7 898.9 962.1 1,040.2 1,118.2
1602 1902 2202 2212 2352 2502 2652 2802 3012 3202 3412 3602 4212 4602 4802
MODELCWP 7.6 9.2 13.3 16.3 19.7 28.0 33.7 40.7 55.8 67.6 87.7 111.9 136.2
02 03 04 05 06 07 09 12 18 21 25 30 35
All performances in kilowatt
44
CONDENSINGUNITS
AQVCAIR COOLED CONDENSING UNITS
6 Cooling modelsFrom 92.1 to 151.0 kW
AQTCAIR COOLED CONDENSING UNITS
7 Cooling modelsFrom 326.0 to 705.6 kW
45
VLCAIR COOLED CONDENSING UNITS
8 Cooling modelsFrom 154 to 347 kW
MODELAQTC 326.0 379.0 408 459 533 623.5 705.6
1206 1355 1506 1656 1806 2106 2406
MODELAQVC 92.1 103.2 113.2 121.8 134.7 151.0
85 95 105 115 125 140
MODELVLC 154 174 199 224 258 283 315 347
524 604 704 804 904 1004 1104 1204
All performances in kilowatt
46
47
Subject to technical modifications, typesetting and printing errors
The manufacturer makes every effort to continuously improve his products and make optimal adaptations to suit theconditions of the respective country of use. For this reason it shall retain the right to undertake technical modifications to theproducts without prior notification.
Range Program / 10-08/1000094 JKP PR
B - A
.2 G
B
Airwell GroupAirwell Group (Headquarter)address:1 bis avenue du 8 Mai 194578284 Guyancourt CedexFrancewww.airwell.com
top related