abbreviations mechanical sheet index
Post on 28-Jan-2022
5 Views
Preview:
TRANSCRIPT
ASSOCIATES
RAIN CONDUCTORRETURN AIR GRILLE
RETURN AIR REGISTER
PHYSICAL HANDICAPPEDPRESSURE RELIEF VALVE
OPPOSED BLADE DAMPEROPEN END DUCT
PUMP #1
SUPPLY AIRROOF SUMP
RETURN AIR
OUTSIDE AIR
STORM
VENTURINAL
SAFE WASTE SINK
VENT THRU ROOF
TRANSFER AIR DUCTTEMPERED WATERUNDERGROUNDUNIT HEATER
SERVICE SINK
SUPPLY DIFFUSERSUPPLY REGISTERSANITARY
WASTE
WATER CLOSETWATER HEATER
REDUCED PRESSURE BACKFLOW PREVENTER
VARIABLE VOLUME AIR TERMINAL BOX
T.A.D.
U/GRD.U.H.
T.W.
V.V.B.V.T.R.
W.H.W.C.
W.
UR.V.
O.A.O.B.D.
P.REL.V.P.H.O.E.D.
R.C.R.A.
RG -#
S.A.R.S.RR-#R.P.B.P.
SR-#SD-#
SAN.
S.W.S.
S.S.ST.
P-1
SUPPLY AIR DIFFUSER
SPIN-IN FITTING W/DAMPER
FLEXIBLE DUCT
RETURN AIR GRILLE
H.V.A.C. SYMBOLS
VOLUME DAMPER
VERTICAL FIRE DAMPER
HORIZONTAL FIRE DAMPER
ABBREVIATIONS
CEILING DIFFUSERCUBIC FEET PER MINUTE
ACOUSTICAL LININGBALANCING VALVE
DAMPER
CAST IRONCLEAN OUT
RECTANGULAR TO ROUND TRANSITION
DRINKING FOUNTAINDRINKING WATER SUPPLY
LINEAR SUPPLY AIR DIFFUSER
EXHAUST REGISTER
INDIRECT WASTEINVERT ELEVATION
ELECTRIC WATER COOLER
HUB OUTLET
FLOOR DRAINFIRE DAMPER
DRINKING WATER RETURNEXHAUST FAN
LAVATORY
HOSE BIBB
LINEAR RETURN AIR DIFUSER
C.F.M.
C.O.DPR.
D.W.S.D.W.R.
EWCER-#
H.B.F.DPR.
H.O.
LAV.LD-#LR-#
I.E.I.W.
F.D.
E.F.
D.F.
C.I.
C.D.B.V.A.L.
.
.
.
DAMPER
T THERMOSTAT
FLEXIBLE CONNECTOR
UNION
STRAINER
THERMOMETER
BALANCING VALVE
CHECK VALVE
GATE VALVE
VENT
GAS OR NG
ST
SAN
DOMESTIC HOT WATER RETURN (H.W.R.)
STORM SEWER
SANITARY SEWER-UNDER GROUND
NATURAL GAS
DOMESTIC HOT WATER (H.W.)
DOMESTIC COLD WATER (C.W.)
PLUMBING & PIPING SYMBOLS
NEW CONNECTION
BALL VALVE
SAN SANITARY SEWER-ABOVE GROUND
MOTOR ACTUATORBALL VALVE
SOLENOID VALVE (NORM. CLOSED)
SOLENOID VALVE (NORM. OPEN)
DIFFERENTIAL REGULATOR
BACK PRESSURE REGULATOR
PRESSURE REGULATOR
PNEUMATIC CONTROL VALVE
DAMPER
MODULATING VALVE
VALVE WITH HANDWHEEL
STOP CHECK STRAIGHT VALVE
GLOBE VALVE
VALVE
CHECK VALVE
GAS COCK VALVE
NEEDLE VALVE
PRESSURE GAUGE TO MATCHEXISTING
TURBINE FLOW METER
CURRENT / PNEUMATIC POSITIONER
INSTRUMENT - NON-ACCESSIBLE
ELECTRIC MOTOR / ACTUATOR
SPARK PLUG
FLEX COUPLING (2 FT MIN)
STEAM TRAP
GENERAL MECHANICAL NOTES:1. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH THE EXISTING
CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS, AND OTHER DRAWINGSFOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THECONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT, ENGINEER, AND/OR OWNER OF CONFLICTS ORDISCREPANCIES PRIOR TO SUBMISSION OF BID.
2. COORDINATE THE INSTALLATION OF THE MECHANICAL SYSTEMS WITH OTHER TRADES TO ENSURE A NEATAND ORDERLY INSULATION. INSTALL PIPING AS TIGHT TO STRUCTURE AS POSSIBLE. COORDINATE WITHOTHER TRADES TO AVOID CONFLICTS. COORDINATE INSTALLATION OF PIPING TO AVOID CONFLICTS WITHELECTRICAL PANELS, LIGHTING FIXTURES, ETC. ANY MODIFICATIONS REQUIRED DUE TO LACK OFCOORDINATION WILL BE THE RESPONSIBILITY OF THE CONTRACTOR AT NO EXTRA COST TO THE OWNER.
3. NEW MECHANICAL PIPING ARE SHOWN AT APPROXIMATE LOCATIONS. FIELD MEASURE FINAL PIPINGLOCATIONS PRIOR TO FABRICATION AND MAKE ADJUSTMENTS AS REQUIRED TO FIT THE PIPING WITHIN THEAVAILABLE SPACE. VERIFY THAT FINAL EQUIPMENT LOCATIONS MEET MANUFACTURER'SRECOMMENDATIONS REGARDING SERVICE CLEARANCE AND PROPER AIRFLOW CLEARANCE AROUNDEQUIPMENT.
4. REFER TO ARCHITECTURAL DRAWINGS FOR RELATED CONSTRUCTION DETAILS AS APPLICABLE TO THEMECHANICAL SYSTEM. VERIFY CHASES AND PENETRATIONS SHOWN ON ARCHITECTURAL DRAWINGS THATARE INTENDED FOR DUCTWORK AND PIPING MEET REQUIREMENTS.
5. INSTALL PIPING PARALLEL TO BUILDING COLUMN LINES UNLESS OTHERWISE SHOWN OR NOTED.
6. OVERHEAD HANGERS AND SUPPORTERS FOR PIPING SHALL BE FASTENED TO BUILDING JOISTS OR BEAMS.DO NOT ATTACH HANGERS AND SUPPORTS TO THE ABOVE FLOOR SLAB OR ROOF EXCEPT WHERECONCRETE INSERTS IN CONCRETE SLABS ARE ALLOWED BY THE SPECIFICATIONS.
7. COORDINATE LOCATION OF SUPPORTERS WITH LOCATION OF EQUIPMENT ACCESS PANELS/DOORS TOENABLE SERVICE OF EQUIPMENT AND/OR FILTER REPLACEMENT.
8. SEAL PENETRATIONS THROUGH THE BUILDING COMPONENTS IN ACCORDANCE WITH THE CONTRACTSPECIFICATIONS. FIREPROOF PENETRATIONS THROUGH FIRE RATED COMPONENTS IN ACCORDANCE WITHU.L. REQUIREMENTS.
9. CONTRACTOR SHALL CEASE WORK AND IMMEDIATELY NOTIFY THE OWNER SHOULD ANY HAZARDOUSMATERIALS BE ENCOUNTERED DURING THE PERFORMANCE OF THE WORK.
10. REFER TO SPECIFICATIONS FOR PIPING INSTALLATION REQUIREMENTS.
DRAIN TRAP
MECHANICAL SHEET INDEX
MECHANICAL LEGEND, SYMBOLS AND SHEET INDEXM.000
SHEET No. DESCRIPTION
M.100
NOT ALL SYMBOLS ARE USED ON THIS PROJECT
M.102 FIRST FLOOR PLAN - DOMESTIC WATER PLUMBING
M.200 FIRST FLOOR PLAN - HVAC
M.201 SECOND FLOOR PLAN - HVAC
M.300 ROOF PLAN - MECHANICAL
SECOND FLOOR PLAN - SANITARY/ VENT PLUMBINGM.101
M.103 SECOND FLOOR PLAN - DOMESTIC WATER PLUMBING
FIRST FLOOR PLAN - SANITARY/ VENT PLUMBING
M.400 MECHANICAL SCHEDULES
M.401 MECHANICAL DETAILS
M.500 MECHANICAL SPECIFICATIONS
ASSOCIATES
PLUMBING NOTES:1. THIS DRAWING IS DIAGRAMMATIC AND SHOULD BE USED TO
DETERMINE THE DESIGN INTENT. THE CONTRACTOR IS RESPONSIBLEFOR THE COMPLETE SET OF WORK AS INDICATED AND SHALL FIELDVERIFY ALL WORK, COORDINATE ALL DRAWINGS / NEW WORK ANDSHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES INTHE DOCUMENTS BEFORE PROCEEDING. FAILURE TO DO SO WILLRESULT IN THE CONTRACTOR TAKING FULL RESPONSIBILITY ANDLIABILITY FOR SAID DISCREPANCIES.
2. COORDINATE PROPER SHUTDOWN OF EXISTING CW SYSTEM WITH THEEND USER PRIOR TO CONNECTION OF NEW SYSTEM.
3. ALL LABOR, VALVES, TRAPS, TAILPIECES, PRESSURE-REDUCINGVALVES, AND FITTINGS REQUIRED FOR FINAL CONNECTION OFEQUIPMENT TO COMPLY WITH ALL CODES, INCLUDING INTERWIRINGCONNECTIONS TO BE FURNISHED BY MECHANICAL CONTRACTORUNLESS OTHERWISE INDICATED.
4. PLUMBING CONTRACTOR TO DO ALL ROUGH-INS AND MAKE ALL FINALCONNECTIONS TO EQUIPMENT.
5. PLUMBING CONTRACTOR TO FURNISH ALL TRIM, ACCESSORIES,VALVES, PRESSURE REGULATORS, P-TRAPS, GREASE TRAPS,BACKFLOW PREVENTION SYSTEM DEVICES ETC.
6. PLUMBING CONTRACTOR TO EXTEND ALL INDIRECT WASTE LINESFROM EQUIPMENT TO NEAREST FLOOR DRAIN / FLOOR SINK ASREQUIRED.
7. COORDINATE FIXTURE, DRAIN, FLOOR SINK & GAS LAYOUT W/ FOODSERVICE CONTRACTOR.
ASSOCIATES
PLUMBING NOTES:1. THIS DRAWING IS DIAGRAMMATIC AND SHOULD BE USED TO
DETERMINE THE DESIGN INTENT. THE CONTRACTOR IS RESPONSIBLEFOR THE COMPLETE SET OF WORK AS INDICATED AND SHALL FIELDVERIFY ALL WORK, COORDINATE ALL DRAWINGS / NEW WORK ANDSHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES INTHE DOCUMENTS BEFORE PROCEEDING. FAILURE TO DO SO WILLRESULT IN THE CONTRACTOR TAKING FULL RESPONSIBILITY ANDLIABILITY FOR SAID DISCREPANCIES.
2. COORDINATE PROPER SHUTDOWN OF EXISTING CW SYSTEM WITH THEEND USER PRIOR TO CONNECTION OF NEW SYSTEM.
3. ALL LABOR, VALVES, TRAPS, TAILPIECES, PRESSURE-REDUCINGVALVES, AND FITTINGS REQUIRED FOR FINAL CONNECTION OFEQUIPMENT TO COMPLY WITH ALL CODES, INCLUDING INTERWIRINGCONNECTIONS TO BE FURNISHED BY MECHANICAL CONTRACTORUNLESS OTHERWISE INDICATED.
4. PLUMBING CONTRACTOR TO DO ALL ROUGH-INS AND MAKE ALL FINALCONNECTIONS TO EQUIPMENT.
5. PLUMBING CONTRACTOR TO FURNISH ALL TRIM, ACCESSORIES,VALVES, PRESSURE REGULATORS, P-TRAPS, GREASE TRAPS,BACKFLOW PREVENTION SYSTEM DEVICES ETC.
6. PLUMBING CONTRACTOR TO EXTEND ALL INDIRECT WASTE LINESFROM EQUIPMENT TO NEAREST FLOOR DRAIN / FLOOR SINK ASREQUIRED.
7. COORDINATE FIXTURE, DRAIN, FLOOR SINK & GAS LAYOUT W/ FOODSERVICE CONTRACTOR.
ASSOCIATES
PLUMBING NOTES:1. THIS DRAWING IS DIAGRAMMATIC AND SHOULD BE USED TO
DETERMINE THE DESIGN INTENT. THE CONTRACTOR IS RESPONSIBLEFOR THE COMPLETE SET OF WORK AS INDICATED AND SHALL FIELDVERIFY ALL WORK, COORDINATE ALL DRAWINGS / NEW WORK ANDSHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES INTHE DOCUMENTS BEFORE PROCEEDING. FAILURE TO DO SO WILLRESULT IN THE CONTRACTOR TAKING FULL RESPONSIBILITY ANDLIABILITY FOR SAID DISCREPANCIES.
2. COORDINATE PROPER SHUTDOWN OF EXISTING CW SYSTEM WITH THEEND USER PRIOR TO CONNECTION OF NEW SYSTEM.
3. ALL LABOR, VALVES, TRAPS, TAILPIECES, PRESSURE-REDUCINGVALVES, AND FITTINGS REQUIRED FOR FINAL CONNECTION OFEQUIPMENT TO COMPLY WITH ALL CODES, INCLUDING INTERWIRINGCONNECTIONS TO BE FURNISHED BY MECHANICAL CONTRACTORUNLESS OTHERWISE INDICATED.
4. PLUMBING CONTRACTOR TO DO ALL ROUGH-INS AND MAKE ALL FINALCONNECTIONS TO EQUIPMENT.
5. PLUMBING CONTRACTOR TO FURNISH ALL TRIM, ACCESSORIES,VALVES, PRESSURE REGULATORS, P-TRAPS, GREASE TRAPS,BACKFLOW PREVENTION SYSTEM DEVICES ETC.
6. PLUMBING CONTRACTOR TO EXTEND ALL INDIRECT WASTE LINESFROM EQUIPMENT TO NEAREST FLOOR DRAIN / FLOOR SINK ASREQUIRED.
7. COORDINATE FIXTURE, DRAIN, FLOOR SINK & GAS LAYOUT W/ FOODSERVICE CONTRACTOR.
ASSOCIATES
PLUMBING NOTES:1. THIS DRAWING IS DIAGRAMMATIC AND SHOULD BE USED TO
DETERMINE THE DESIGN INTENT. THE CONTRACTOR IS RESPONSIBLEFOR THE COMPLETE SET OF WORK AS INDICATED AND SHALL FIELDVERIFY ALL WORK, COORDINATE ALL DRAWINGS / NEW WORK ANDSHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES INTHE DOCUMENTS BEFORE PROCEEDING. FAILURE TO DO SO WILLRESULT IN THE CONTRACTOR TAKING FULL RESPONSIBILITY ANDLIABILITY FOR SAID DISCREPANCIES.
2. COORDINATE PROPER SHUTDOWN OF EXISTING CW SYSTEM WITH THEEND USER PRIOR TO CONNECTION OF NEW SYSTEM.
3. ALL LABOR, VALVES, TRAPS, TAILPIECES, PRESSURE-REDUCINGVALVES, AND FITTINGS REQUIRED FOR FINAL CONNECTION OFEQUIPMENT TO COMPLY WITH ALL CODES, INCLUDING INTERWIRINGCONNECTIONS TO BE FURNISHED BY MECHANICAL CONTRACTORUNLESS OTHERWISE INDICATED.
4. PLUMBING CONTRACTOR TO DO ALL ROUGH-INS AND MAKE ALL FINALCONNECTIONS TO EQUIPMENT.
5. PLUMBING CONTRACTOR TO FURNISH ALL TRIM, ACCESSORIES,VALVES, PRESSURE REGULATORS, P-TRAPS, GREASE TRAPS,BACKFLOW PREVENTION SYSTEM DEVICES ETC.
6. PLUMBING CONTRACTOR TO EXTEND ALL INDIRECT WASTE LINESFROM EQUIPMENT TO NEAREST FLOOR DRAIN / FLOOR SINK ASREQUIRED.
7. COORDINATE FIXTURE, DRAIN, FLOOR SINK & GAS LAYOUT W/ FOODSERVICE CONTRACTOR.
S-3300 CFM
S-3300 CFM
S-3300 CFM
S-3300 CFM
S-3250 CFM
S-3250 CFM
S-3300 CFM
S-3300 CFM
S-3175 CFM
R-1
R-1
S-3200 CFM
S-3200 CFM
S-3200 CFM
S-3200 CFM
S-3200 CFM R-1
R-1
E-1125 CFM
E-1100 CFM
E-175 CFM
S-4125 CFM
S-450 CFM
S-3250 CFM
30x14 OPEN ENDRETURN AIR DUCT
30x16 S.A. DUCTUP TO HVAC30x18 R.A. DUCTUP TO HVAC
T
TO HVAC
S-3300 CFM
S-3300 CFM
S-3300 CFM
S-3300 CFM
S-3250 CFM
S-3250 CFM
S-3300 CFM
S-3300 CFM
S-3175 CFM
R-1
R-1
S-3200 CFM
S-3200 CFM
S-3200 CFM
S-3200 CFM
S-3200 CFM
R-1
R-1
E-1125 CFM
E-1100 CFM
E-175 CFM
S-4125 CFM
S-450 CFM
S-3250 CFM
30x16 OPEN ENDRETURN AIR DUCT
20x14 S.A. DUCTUP TO HVAC
30x18 R.A. DUCTUP TO HVAC
T
TO HVAC
30x16
20x1024x16
14x10
24x16
12x8
30x16 24x16
24x16
14x10
20x10
12x8
S-3200 CFM
S-4125 CFM
S-3200 CFM
S-3200 CFM
S-3200 CFM
S-2100 CFM
S-2100 CFM
10x8
10x6
E-1125 CFM
E-1100 CFM
8x6 EXHAUST DUCTUP TO EF ON ROOF
10x8 S.A.DUCT UP
ECUH-25 KW
ECUH-15 KW
T
T
TR-1TR-1
TR-1
EWUH-13 KW
EWUH-23 KW
TO HVAC
TO HVAC
GAS METER & SERVICE BYLOCAL COMPANY ( CFH),VERIFY IN FIELD EXACTSIZES & LOCATION
2" GAS LINE (1520CFH) UP TO ROOF
18x8 S.A.DUCT UP
14x8
ASSOCIATES
HVAC NOTES:1. ALL NEW MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL
BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED.
2. COORDINATE THE EXACT MOUNTING SIZE AND FRAME TYPE OF DIFFUSERS,REGISTERS, AND GRILLES WITH THE SUPPLIER TO MEET THE CEILING, WALL,AND DUCT INSTALLATION REQUIREMENTS.
3. ADJUST LOCATION OF CEILING DIFFUSERS, REGISTERS, AND GRILLES ASREQUIRED TO ACCOMMODATE FINAL CEILING GRID AND LIGHTING LOCATIONS.
4. PROVIDE A PREFABRICATED RECTANGULAR/ROUND BRANCH DUCT TAKEOFFFITTING WITH MANUAL BALANCING DAMPER AND LOCKING QUADRANT FORBRANCH DUCT CONNECTIONS AND TAKE-OFFS TO INDIVIDUAL DIFFUSERS,REGISTERS AND GRILLES.
5. BRANCH DUCTWORK TO AIR OUTLETS SHALL BE SAME SIZE AS OUTLET NECKSIZE UNLESS OTHERWISE NOTED.
6. REFER TO SPECIFICATIONS FOR DUCTWORK AND PIPING INSULATIONREQUIREMENTS. DUCT SIZES ON MECHANICAL PLANS INDICATE CLEAR INSIDEAIRFLOW DIMENSIONS.
7. FLEXIBLE DUCTWORK SHALL NOT EXCEED 5'-0" IN LENGTH AND SHALL BEINSTALLED AND SUPPORTED TO AVOID SHARP BENDS AND SAGGING. REFER TOSPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
8. IN EXPOSED AREA (NO CEILING). PROVIDE PREFABRICATED SPIRAL ROUND DUCTOF SIZES AS SHOWN ON DWG UNLESS OTHERWISE NOTED.
E-175 CFM
S-450 CFM
E-175 CFM
S-450 CFM
S-2100 CFM10"Ø NKS-2100 CFM10"Ø NK
30x16 S.A. DUCTUP TO HVAC
30x18 R.A. DUCTUP TO HVAC
30x16 S.A. DUCTUP TO HVAC
30x18 R.A. DUCTUP TO HVAC
12x8 EXHAUST DUCTUP TO EF ON ROOF
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-350 CFM
S-2200 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
S-1715 CFM
HVAC-125 TON10000 CFMON ROOF
HVAC-225 TON10000 CFMON ROOF
E-175 CFM
6x4
8x6 EXHAUST DUCTUP TO EF ON ROOF
24"Ø
30"Ø
30"Ø
54x20 OPEN ENDRETURN AIR DUCT
24"Ø
30"Ø
24"Ø
54x20 R.A. DUCTUP TO HVAC54x20 R.A. DUCT
UP TO HVAC
54x20 OPEN ENDRETURN AIR DUCT
OPEN ENDRETURN AIR DUCT50x20 S.A. DUCT
UP TO HVAC50x20 S.A. DUCTUP TO HVAC
8"Ø
8"Ø
TR-1
EWUH-33 KW
EWUH-43 KW
HVAC-310 TON4000 CFMON ROOF
HVAC-410 TON4000 CFMON ROOF
18x8 S.A.DUCT DN
10x8 S.A.DUCT DN
ASSOCIATES
HVAC NOTES:1. ALL NEW MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL
BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED.
2. COORDINATE THE EXACT MOUNTING SIZE AND FRAME TYPE OF DIFFUSERS,REGISTERS, AND GRILLES WITH THE SUPPLIER TO MEET THE CEILING, WALL,AND DUCT INSTALLATION REQUIREMENTS.
3. ADJUST LOCATION OF CEILING DIFFUSERS, REGISTERS, AND GRILLES ASREQUIRED TO ACCOMMODATE FINAL CEILING GRID AND LIGHTING LOCATIONS.
4. PROVIDE A PREFABRICATED RECTANGULAR/ROUND BRANCH DUCT TAKEOFFFITTING WITH MANUAL BALANCING DAMPER AND LOCKING QUADRANT FORBRANCH DUCT CONNECTIONS AND TAKE-OFFS TO INDIVIDUAL DIFFUSERS,REGISTERS AND GRILLES.
5. BRANCH DUCTWORK TO AIR OUTLETS SHALL BE SAME SIZE AS OUTLET NECKSIZE UNLESS OTHERWISE NOTED.
6. REFER TO SPECIFICATIONS FOR DUCTWORK AND PIPING INSULATIONREQUIREMENTS. DUCT SIZES ON MECHANICAL PLANS INDICATE CLEAR INSIDEAIRFLOW DIMENSIONS.
7. FLEXIBLE DUCTWORK SHALL NOT EXCEED 5'-0" IN LENGTH AND SHALL BEINSTALLED AND SUPPORTED TO AVOID SHARP BENDS AND SAGGING. REFER TOSPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
8. IN EXPOSED AREA (NO CEILING). PROVIDE PREFABRICATED SPIRAL ROUND DUCTOF SIZES AS SHOWN ON DWG UNLESS OTHERWISE NOTED.
EF-1750 CFMON ROOF
EF-2300 CFMON ROOF
GA
SG
AS
GA
SG
AS
GA
S
3" GAS LINE (5,159 CFH) BASED ONINITIAL SUPPLY PRESSURE OF 11.0 "WCOR GREATER, VERIFY WITH UTILITYCOMPANY & COORDINATE AS REQUIRED
GA
SG
AS
GA
SG
AS
GAS METER & SERVICE BY LOCALCOMPANY (5,159 CFH), VERIFY INFIELD EXACT SIZES & LOCATION
GA
SG
AS
GA
SG
AS
GA
S
GAS
GASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
2" GAS LINE (1520CFH) UP TO ROOF
SHUT-OFFVALVE
SHUT-OFFVALVE
SHUT-OFFVALVE
SHUT-OFFVALVE
GAS GAS GAS GAS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
S
1" GAS ONROOF
1" GAS ONROOF
1" GAS ONROOF
1" GAS ONROOF
HVAC-125 TON10000 CFM400 CFH
HVAC-225 TON10000 CFM400 CFH
HVAC-310 TON4000 CFM250 CFH
HVAC-410 TON4000 CFM250 CFH
1 1/4" GAS ONROOF
3/4" GASON ROOF
1" GASON ROOF
2" GAS ON ROOF
3/4" GAS TO WATER HEATER,FOR CONTINUATION REFERTO SHEET M.101
6" SECONDARYSTORM LINE
STORM NOZZLE,COORDINATE EXACTLOCATION W/ARCHITECT
6" MAIN STORM LINE
6" ST DN TO UNDERGROUND.REFER TO SANITARY & VENTPLUMBING PLAN ON SHEET M.100
6"SRS
6" SECONDARYSTORM LINESTORM NOZZLE,COORDINATE EXACTLOCATION W/ARCHITECT
6"RS
4"SRS 4"RS
6" ST DN TO UNDERGROUND.REFER TO SANITARY & VENTPLUMBING PLAN ON SHEET M.100
4"SRS 4"RS 4"SRS 4"RS3"SRS 3"RS 3"SRS3"RS
6" MAIN STORM LINE
4" MAIN STORM LINE 4" ST DN TO UNDERGROUND.REFER TO SANITARY & VENTPLUMBING PLAN ON SHEET M.100
3" MAIN STORM LINE
4" MAIN STORM LINE
3" MAIN STORM LINE
4" ST DN TO UNDERGROUND.REFER TO SANITARY & VENTPLUMBING PLAN ON SHEET M.100
4" SECONDARYSTORM LINE
3" SECONDARYSTORM LINE
4" SECONDARYSTORM LINE
4" SECONDARYSTORM LINE
3" SECONDARYSTORM LINE
STORM NOZZLE,COORDINATE EXACTLOCATION W/ARCHITECT
STORM NOZZLE,COORDINATE EXACTLOCATION W/ARCHITECT STORM NOZZLE,
COORDINATE EXACTLOCATION W/ARCHITECT
STORM NOZZLE,COORDINATE EXACTLOCATION W/ARCHITECT
STORM NOZZLE,COORDINATE EXACTLOCATION W/ARCHITECT
4" MAIN STORM LINE
6"RS 6"SRS
2" GAS LINE UP
2 1/2" GAS LINE UNDERGROUND TOEMERGENCY GENERATOR (3,420 CFH),COORDINATE WITH LOCAL GAS COMPANY,CIVIL & ELECTRICAL DRAWINGS
ASSOCIATES
MECHANICAL ROOF NOTES:1. ALL NEW MECHANICAL EQUIPMENT SHOWN ON THE
MECHANICAL PLANS SHALL BE PROVIDED BY THEMECHANICAL CONTRACTOR UNLESS OTHERWISENOTED.
2. REFER TO SPECIFICATIONS FOR DUCTWORK ANDPIPING INSULATION REQUIREMENTS.
ASSOCIATES
ELECTRIC WALL UNIT HEATER SCHEDULETAG
BASIS OFDESIGN
MODEL LOCATION TYPECAPACITY(WATTS)
ELECTRICALVOLT/PH/HZ
NOTES /ACCESSORIES
EWUH-1 Q-MARK LFK 404F STAIRS WALL 3000 208 / 1 /60WALL MOUNTED ACCESSORIES,
TEHRMAL OVERHEAT PROTECTOR,BUILTIN POWER DISCONNECT SWITCH,
UNIT MOUNTED THERMOSTAT.
EWUH-2
EWUH-3
EWUH-4
120V/1Ø, DISCONNECT SWITCH
NATURAL GAS
EXPANSION TANK
DOMESTIC WATER HEATER SCHEDULE
POWER VENTED
P & T RELIEF TO FD
FLOOR MOUNTED
C
A
B
F
E
D
& MODEL No.MANUFACTURER
WH-1
TAG LOCATION
CAPACITIES
RECOVERY
NOTES AND ACCESSORIES DESIGNATION
STORAGE TD °F ØFLUE NOTES/ACCESSORIESGAS
INPUT CFH
WH-2
CFH
GAS LOAD SCHEDULETOTAL INPUT
NATURAL
EQUIPMENT
250
TOTAL 5,159 CFH
HVAC-3
400HVAC-1
400HVAC-2
HVAC-4 250
WATER HEATER - 1 199
WATER HEATER - 2 120
WATER HEATER - 3 120
WH-3
BTH-120A.O. SMITH SEE 60 173 80 4" A B C D E F120DRAWINGS
BTH-120A.O. SMITH SEE 60 173 80 4" A B C D E F120DRAWINGS
BTH-199A.O. SMITH SEE 100 223 100 4" A B C D E F199
DRAWINGS
GREASE TRAP SCHEDULE
SIZE OUTLETSIZE (IN)
FLOW RATE(GPM)
CAPACITYWATER (GPM)
CAPACITYGREASE (LBS)
MANUFACTURERMODEL #TAG
GT ZURNZ1170
600 3 25 21 50
SUS - SUSPENDED
B
A INTEGRAL THERMOSTAT
BUILT-IN DISCONNECT
NOTES AND ACCESSORIES DESIGNATION
SW - SURFACE WALLRW - RECESSED WALL
ECUH-1
MOUNTING KEY
CABINET UNIT HEATER SCHEDULEELECTRICAL DATA
KW INPUTLOCATIONTAG
MANUFACTURER
& MODEL No.MOUNTING CFM
AMPSMBH NOTES/ACCESSORIES
VOLT
VESTIBULEMARKEL6300 SERIES
350 --17.05 5.0 208/1 A B
C REMOTE THERMOSTAT
D HANGING KIT
RC - RECESSED CEILING
RCECUH-2
EMERGENCY GAS GENERATOR 3,420
ASSOCIATES
DAMPER BACKDRAFT
PRIMER COAT AND PAINT EXTERIOR GAS PIPE.GRAVEL IF ANY. INSTALL GAS PIPE TO ALLOW FOR EXPANSION AND CONTRACTION.1-1/2"=9', 1-1/4"=8', 1"=7', 3/4"=6'. PLACE BASE SHEETS ON ROOFING BEFORESUPPORT SPACING FOR PIPE SIZE: 5"=16', 4"=14', 3"=12', 2-1/2"=11', 2"=10'
NYLON ROLLER
MIRO MODEL 3-R
HVAC UNIT
INSULATION OVERDUCTWORK
FLEX. CONN.
ROOFING MEMBRANE
RAIL ON UNIT CURB PROVIDE ISOLATION
COUNTER FLASHING
AIRSUPPLY
2" BLANKET WRAP
CONT. CANT STRIP
FILL CURB SPACE BETWEENHVAC AND ROOF WITHBATT INSULATION
CURB (BY UNIT MANUFACTURER)
OPENING IN TOP
RETURNAIR CEILING
OF MAIN
GASKET
OUTDOOR AIR INTAKE HOOD
VENT REGULATORTO ATMOSPHERE IF
UNION (SHOWN) ORFLANGED CONNECTIONPLUG
COCKS
REQUIRED
MAXIMUM
6'-0"
GAS-FIREDEQUIPMENT
OR HAND SINKTO LAVH. & C.W.
PIPINGSUPPLY
SINK)(LOCATE VALVE UNDERSET @ 110°F MAXIMUMAPOLLO ASSE 1070, 34D SERIESMIXING VALVE
(2) 90 DEG. ELBOWS. ELBOWSTO BE MADE WITH MINIMUMRADIUS OF 1 1/2 R/D.
MAXIMUM OF 5ft. LONGFLEXIBLE DUCTWORK WITH
WITH DAMPERSPIN IN FITTING
S.A. DUCT
AIR TERMINAL UNIT
BELOW FLOOR SLAB WITHOUT JOINTS.SLOPE TOWARD FLOOR DRAIN TRAP.PROVIDE ELASTOMERIC INSULATIONFROM TRAP TO ABOVE FLOOR SLAB.
PROVIDE COUPLING
TYPE "K" SOFT COPPER TUBE
CONCRETE FLOOR
FLOOR DRAIN
PRIMER CONNECTIONP-TRAP WITH TRAP
PRIMER.
WATER DAILY) IN CEILING MAKE BRANCH TO
MORE THAN ONE TRAP IS SERVED BY A
DOMESTIC COLD WATER LINE (THAT FLOWS
TRAP PRIMER OFF TOP OF THIS PIPE.
PROVIDE DISTRIBUTION UNITS WHERE
CEILING
VENT
IF 3"V NOT USED
3"x2" BUSHINGS OR3"x2-1/2" BUSHINGS
ROOF BOOT/FLASHING
AIRCOMBUSTION
MAINTAIN 36"MIN.CLEARENCE ABOVEHIGHEST ANTICIPATEDSNOW LEVEL. MAXOF 24" ABOVE ROOF
ROOF
VENT
UNION
HOT WATER
FLOOR
THERMOSTAT & PILOT
HEATER
(TYP.)
DIRT LEG-FULL SIZE(CAPPED)
GAS COCK
PIPE TO FLOORRELIEF VALVE
DRAIN
FLOOR DRAIN
6" MIN.
G
EXPANSION TANK
PVC INTAKE &EXHAUST
GAS MAIN
(BY SITE UTILITESWATER SERVICE
6"
CONTRACTORS)CONC. SUPPORT
BYPASS
BE INSTALLED PER LOCAL CITYREQUIREMENTS
METER AND BACKFLOW PREVENTER TO
M
F.D.
NOTE
METERWATER
PREVENTERBACKFLOW
BFP CW
CW
HW
CP-1HWR
SPKR SYSTEM (ZONE-2)
SPKR SYSTEM (ZONE-1)
CHECK VA.
WATER ALARM GONGALARM CHECK VA.
BALL CHECK & DRIP
(TYPICAL EACH ZONE)
ARCH. TRADESSPLASH BLOCK BY
2" ANGLE
2" DRAIN
OS & Y VA.
VALVE
WALL
CONNECTIONSIAMESE
OUTSIDE
ALARM BELL(TYP.)
PRESSURE GAUGE
DRAIN VALVE
FINISHED FLOOR
RETARD CHAMBER
FLOW SWITCH
TO FIRST FLOOR
TO FIRST FLOOR
(BY SITE UTILITIESCONTRACTOR)
PROVIDE REDUCED PRESSURE BACKFLOWPREVENTER IF REQUIRED BY APPLICABLE
DETECTOR CHECK
WATER SERVICE
PIPE SUPPORTS
DRAIN VALVES
6"
NOTES:1.
CODES.
4"
3/4" HW & CWDRAINBOARD
FLOW CONTROL (TYP)TAIL PIECE INSTALL.
GREASE TRAP
3"
2" WASTE& V DN
2"
2" VENT UP
2" VENT UP& DOWN
2"AIR GAP
(TYP)
FLOOR SINK W/SEDIMENT BUCKET
3" TO SAN.
FINISHED FLOOR
(TYP)
LEVER DRAIN.
DEPTH AS REQUIRED
1" AIR GAP FLOOR
INDIRECT WASTE FROMEQUIPMENT
ASSOCIATES
PROVIDE CLEANOUTS AS REQUIRED BY LOCAL CODES. THE FINISH OF COVER PLATES, TOPAND TOP FRAME ACCESS COVERS SHALL BE NICKEL BRONZE, UNLESS OTHERWISE SCHEDULED.
PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR CLEAN OUTS AND PROPER VENTING OF PLUMBING
PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL EQUIPMENT, BACK FLOW PREVENTERS, VALVES,UNIONS, BY-PASS PIPING AND ALL REQUIRED ACCESSORIES, BY LOCAL AUTHORITIES HAVING JURISDICTION,TO MAKE A COMPLETE AND OPERATING SYSTEM. COMPLY WITH APPLICABLE PLUMBING CODES FOR ALL INSTALLATION.
PROVIDE FOR EXPANSION, PROPER HANGERS AND SUPPORTS FOR ALL PIPING. PROVIDE NECESSARY VALVES,
WATER SERVICE LINES TO PLUMBING FIXTURES SHALL BE TYPE "L" COPPER FOR UNDERGROUND AND TYPE
CONTRACTOR SHALL PROVIDE PIPES PENETRATE EXTERIOR WALL AND WEATHER PROOF AS REQUIRES.
PLUMBING WORK SHALL COMPLY WITH STATE PLUMBING CODE AND ALL OTHER AUTHORITY HAVING
MECHANICAL CONTRACTOR SHALL PAY FOR REQUIRED PERMITS, INSPECTIONS AND TAP-IN FEES.
UNIONS, DIRTY TRAPS AS REQUIRED FOR EACH PIECE OF EQUIPMENT AND FIXTURES.
SANITARY PIPING SHALL SLOPE 1/8"PER FOOT IN DIRECTION OF FLOW.
CONTRACTOR SHALL FLUSH SANITIZE ALL PIPING PER CODE REQUIREMENT.
DRAIN PIPING: TYPE "L" COPPER WITH FPC OR PF INSULATION.
INDICATED, CONFORMING TO ASTM B88 WITH EITHER WROUGHT COPPER OR CAST BRASSDOMESTIC WATER PIPING: PROVIDE COPPER TUBING, TYPE L HARD DRAWN OF SIZES AS
CONFORMING TO CISPI 501 WITH CISPI 310 COUPLING JOINTS AND OF SIZES AS INDICATED.SANITARY WASTE AND VENT PIPING: PROVIDE CAST IRON HUBLESS PIPE AND FITTINGS
PROVIDE ECCENTRIC REDUCERS FOR CHANGES IN WASTE PIPE LINES.
ADAPTERS FOR CONNECTION TO THREADED VALVES AND FITTINGS SHALL BE
SOLDER SHALL CONFORM WITH ASTM B88 TIN LEAD-FREE SOLDER.
GAS PIPING WITH DRIPLEG AND SHUT OFF GAS VALVE, COMPLY WITH MANUFACTURERSMALLEABLE IRON FITTING IN ACCORDANCE WITH ANSI B165 CLASS 150. CONNECTACCORDANCE WITH "NFPA 54" AND "ASTM A55" PROVIDE SCREWED GALVANIZEDNATURAL GAS PIPING: STD WEIGHT BLACK STEEL, FABRICATED AND INSTALLED IN
CLOSE WHEN FAN STOPS.
ACCEPTABLE MANUFACTURERS: COOK, GREENHECK AND ACME.
PROVIDE PIPING SYSTEMS LAID OUT AND INSTALLED IN ACCORDANCE WITH LATEST
GAS PIPING WHERE INDICATED, INCLUDE ALL HANGERS, SUPPORTS ETC... REQUIREDGENERAL: FURNISH AND INSTALL WATER, SANITARY, DRAIN, VENT, AND NATURAL
1. ACCEPTABLE MANUFACTURERS: LOCKINVAR AND O.A. SMITH.
LATEST "PRESSURE VESSEL CODES". UNITS SHALL BE PLUMBED AND WIRED PERASSEMBLED. UNIT SHALL BE "UL" LISTED AND LABELED AND COMPLY WITH THE FURNISH AND INSTALL GAS WATER HEATER THAT IS FACTORY TESTED AND
NATIONAL PLUMBING CODE OR INTERNATIONAL PLUMBING CODE.
STANDARDS AND "NFPA 70" NATIONAL ELECTRICAL CODE.AND LABLED. MOTOR AND ELECTRICAL ACCESSORIES SHALL COMPLY WITH NEMAFANS SHALL COMPLY WITH "UL" 705 "POWER VENTILATORS" AND SHALL BE LISTED
PIPING / PLUMBING
FOR A COMPLETE INSTALLATION.
A.
B.
MANUFACTURERS WRITTEN INSTRUCTIONS.
WATER HEATER
A.
4.
3.
THE WORK INCLUDED IN THE CONTRACT SHALL CONSIST OF FURNISHING,INSTALLING, LASTING AND GUARANTEEING OF THE FOLLOWING WORK:
AND BACK DRAFT DAMPER MOUNTED IN CURB BASE, FACTORY SET TO PROVIDE THE FOLLOWING ACCESSORIES: DISCONNECT SWITCH, BIRD SCREEN
COORDINATE LOCATION AND DIMENSIONS. PROVIDE WALL LOUVER WHEREPROVIDE HANGING VIBRATION ISOLATORS AND NESSESSARY ACCESSORIES.
FABRICATED AND ASSEMBLED WITH CAPACITY AS SCHEDULED.FURNISH AND INSTALL CENTRIFUGAL AND CABINET EXAUST FAN THAT IS FACTORY
ACCEPTABLE MANUFACTURERS: TRANE, LENNOX, CARRIER OR EQUAL.
PLUMB AND LEVEL FIRMLY ANCHORED IN INDICATED LOCATION.INSTALL UNIT IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS
AGA SAFTY STD, AND ASHRAE 15 "SAFETY CODE FOR MECHANICALHVAC UNITS SHALL BEAR "UL" LABEL. UNIT SHALL COMPLY WITH
AND TEMPERATURE CONTROL, FILTERS AND DAMPERS.CONSISTING OF: BLOWER, EVAPORATOR COIL, ECONOMIZER, REFRIGERANTHVAC UNITS SHALL BE FACTORY ASSEMBLED AND TESTED.
TESTS, ADJUSTMENTS AND BALANCING OF ALL SYSTEMS.
HOT AND COLD WATER PIPING AND INSULATION.LOW PRESSURE DUCT WORK AND INSULATION.
IN A PROFESSIONAL MANNER AND SHALL MEET ALL THE
SAFETY AND HEALTH CODES, NFPA, STATE CODES AND ALL OTHER APPLICABLEREQUIREMENTS OF THE STATE BUILDING CODE, CITY BUILDING CODE,
COMPLETE AND OPERATING SYSTEM. ALL WORK SHALL BE INSTALLEDNOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE AAND AIR CONDITIONING SYSTEM. INCLUDE ANY LABOR AND MATERIALDETAILS NECESSARY TO PROVIDE A COMPLETE HEATING, VENTILATINGFURNISH ALL LABOR, MATERIAL, TOOLS INCIDENTALS AND
CODES AND REGULATIONS.
1.
POWER VENTILATORS
APPLICABLE.
REFIGERATION".
2.
A.
1.
3.
2.
CAPACITY AS INDICATED ON SCHEDULE.
HVAC UNITS.
AIR DEVICES / ACCESSORIES.POWER VENTILATORS.
WATER HEATERS.SANITARY PIPING.
7.
A.
HVAC UNIT
8.
1.
4.
6. 5.
2. 3.
B.
SPECIFICATIONS
GENERAL
A.
PLUMBING FIXTURE SCHEDULE:
"M" COPPER FOR ABOVE FLOOR OR PEX IF APPROVED BY LOCAL AHJ.
CLEANOUTS:
O.
M.
N.
L.
IN ACCORDANCE WITH THE LATEST PLUMBING CODE.
RECESSED SOLDER JOINT FITTINGS.
G.JURISDICTION.
K.
J.
H.
I.
CAST BRASS. 1.
2.
F.
PIPING / PLUMBING CONT'D
INSTRUCTIONS.
E.
D.
C.
ALL AUTOMATIC TEMPERATURE CONTROLS SHALL BE ADJUSTED AND SET FOR PROPER
SHEAVES, BELTS AND DAMPERS AND ALSO THE ADDITION OF DAMPERS AS REQUIRED FOR THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING ALL REQUIRED CHANGES IN THE
SHALL COMPLY WITH THE LATEST STANDARDS OF THE ASSOCIATED AIR BALANCE COUNCILBALANCE AIR QUALITIES TO WITHIN 5% AND LOCK VOLUME REGULATORS. AIR BALANCING
BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO RELEASE OF FINAL PAYMENT.
CORRECT BALANCE.
OPERATION.
OR THE NATIONAL ENVIROMENTAL BALANCING BUREAU.
D.
C.
B. -+
INCLUDING THE PAYMENT OF ALL COSTS OF SUCH TESTS. AIR BALANCE REPORT SHALLTEST AND ADJUSTMENTS OF ALL SPECIFIED SHALL BE MADE BY THIS CONTRACTOR,
BLANKET "UL" LABELED REINFORCED VAPOR BARRIER JACKET, 0.3 K FACTOR AT 75 F.SUPPLY DUCTS: FDB-FIBERGLASS DUCT BLANKET, FOIL FACED FIBERGLASS DUCT WRAP
WATER PIPING: GLASS FIBER COVERING 0.26K FACTOR @ 75 F, SINGLE CYLINDRICAL
ADHESIVE, SEALERS, JACKETS ETC... FOR A COMPLETE INSTALLATION. EXPOSED ROUNDGENERAL: PROVIDE PIPE AND DUCT INSULATION AS DESCRIBED BELOW. INCLUDE ALL
FURNISH AND INSTALL ALL AIR DEVICES ( DIFFUSERS, GRILLES) AS SCHEDULED. ACCEPTABLE
FLEXIBLE DUCT CONNECTIONS WITH PANDUIT ADJUSTABLE DIAMETER RYLON CLAMPS.GENFLEX MODEL #SM-2DE CONICAL FITTING AT NEW RUN OUTS FROM MAIN. SECURE ALLFURNISH AND INSTALL FLEXIBLE ROUND DUCTS TO AIR DEVICES GENFLEX TYPE SLR FAN
NOT EXCEEDING FOUR (4') FEET SPACING. GAGES FOR ROUND AND RECTANGULAR LOW SUPPORTED AND ANCHORED TO THE BUILDING CONSTRUCTION WITH DOUBLE-STRAP HANGERSAND AIR CONDITIONING SYSTEM" PUBLISHED BY "SMACNA". DUCTS SHALL BE SECURELY
ALL SHEET METAL WORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH
FURNISH AND INSTALL GALVANIZED DUCTWORK AND ACCESSORIES AS INDICATED ON
THE LATEST EDITION OF THE " DUCT MANUAL AND SHEET METAL CONSTRUCTION FOR VENTILATING
PRESSURE SHALL BE PER SMACNA 0-2 INCHES STATIC PRESSURE CLASS
TEST AND ADJUSTMENTS:
INSULATION
1. LOW PRESSURE DUCT WORK: 1 1/2 INCH
DUCTWORK IS NOT TO BE INSULATED.
CONSTRUCTION.
MANUFACTURERS: TITUS, CRANE AND KRUGER.
DRAWING.
SHEET METAL AND ACCESSORIES
A.
C.
B.
A.
D.
C.
B.
A.
FD
o
3"
FIXTURE CONNECTIONS SHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE:
WATER CLOSETS (FLUSH TANK)
LAVATORY
FIXTURE
1-1/2"
4"
WASTESOIL OR
1-1/2"
VENT TRAP
1/2"
WATER HOT
o
3/4"
1/2"
WATER COLD
LOCATION: TOILETS AND WHERE INDICATED. MODEL NO. Z-415 ADJUSTABLE.STRAINER, FINISHES AND REMARKS: 5" DIAMETER TYPE "B" STRAINER NICKEL BRONZE WITH INTEGRAL
FD-1 GENERAL FLOOR DRAIN:
SEEPAGE PAN, CLAMPING COLLARS, EXTENSION SLEEVES OR FRAMES.
FLOOR DRAIN SCHEDULE:
1-1/2"
MOP SINK 3" 1-1/2" 3/4" 3/4"3"
FAUCETS SHALL BE SYMMONS, CHICAGO OR SPEAKMAN.TOILET SEATS SHALL BE OPEN FRONT OLSONITE, CHURCH, CENTOCO OR BENEKE.FLUSH VALVE SHALL BE SLOAN OR ZURN.FIXTURE SUPPORTS SHALL BE ZURN. J.R. SMITH, JOSAM OR WADE.
FIXTURES SHALL BE AMERICAN STANDARD, KOHLER OR CRANE. AMERICAN STANDARD MODEL NUMBERS ARE USED TO ESTABLISH A STANDARD.
KITCHEN SINK 1-1/2" 1-1/2" 1/2" 1/2"1-1/2"
ELECTRIC WATER COOLER 1-1/2" 1-1/2" 1/2"1-1/2"
PLUMBING SPECIALTIES:PLUMBING SPECIALTIES SHALL BE JOSAM, J.R. SMITH, WADE, MIFAB, SIOUX CHIEF OR ZURN.
CLEANOUTS: THREADED BRASS PLUGS WITH ZURN Z-1460-9 STAINLESS STEEL COVER IN WALLS AND Z-1400-2NICKEL BRONZE SCORIATED COVER IN FLOORS.
FLOOR DRAINS: CONTRACTOR HAS THE OPTION OF USING TRAP PRIMERS OR TRAP SEAL DEVICES AS FOLLOWS:
TRAP SEALS SHALL BE PROVIDED FOR ALL FLOOR DRAINS, FLOOR SINKS AND OTHERS TO PREVENT TRAPEVAPORATION. SEALS SHALL BE EQUAL TO SURESEAL, SIZED TO MATCH THE DRAIN TRAP.
TRAP PRIMERS SHALL BE MIFAB, SMITH OR ZURN Z-1022 "SANI-GARD", ALL BRONZE BODY WITH INTERNALVACUUM BREAKER, ANTI-BACK-SIPHON DESIGN, NON-LIMING OPERATING ASSEMBLY, REPLACEABLE VALVE SEAT,GASKETED BRONZE COVER, CHROME PLATED FINISH. LOCATE TRAP PRIMER VALVES ON THE NEARESTDOMESTIC COLD WATER MAIN SERVING THE SPACE AND PIPE TO FLOOR DRAIN TRAP PRIMER CONNECTION.PROVIDE HEAT TRAPS IN BOTH HOT AND COLD WATER PIPE RISERS AT WATER HEATERS UNLESS TRAPS AREINTEGRAL WITH THE HEATERS.
URINAL 2" 1-1/2" 3/4"2"
SYSTEM SHALL BE SIZED PER NFPA STANDARDS, BUILDING CONSTRUCTION AND OCCUPANCY
AND BE IN ACCORDANCE WITH THE OWNER'S (LANDLORD'S) CRITERIA AND INSURING AGENCY.
THE CONTRACTOR SHALL HYDRAULICALLY DESIGN THE PIPE SIZING.
CONTRACTOR SHALL BE LICENSED IN THE STATE OF MICHIGAN FOR THE DESIGN AND
INSTALLATION OF FIRE PROTECTION SYSTEMS.
CONTRACTOR SHALL PREPARE SHOP DRAWINGS OF THE COMPLETE INSTALLATION AND SUBMIT
FOR APPROVAL TO THE LOCAL FIRE MARSHAL AND TO THE OWNER'S INSURING AGENCY.
PIPING SHALL BE SCHEDULE 40, BLACK STEEL PIPE WITH SPRINKLER PATTERN CAST-IRON
SCREWED AND SCREWED FLANGE FITTINGS, 175 PSI S.W.P. UL APPROVED. CONTRACTOR SHALL
HAVE OPTION TO USE APPROVED LESSER WALL THICKNESS PIPE AND ROLL GROOVE TYPE
COUPLINGS EQUAL TO VICTAULIC OR TOTAL LOCK.
PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH WALLS.
PROVIDE AND INSTALL ALL HANGERS OF APPROVED TYPE. INSTALLATION SHALL CONFORM TO
NFPA STANDARD NO. 13.
PROVIDE AND INSTALL UL LISTED VALVES.
SPRINKLER HEADS SHALL BE "QUICK RESPONSE" TYPE AS MANUFACTURED BY GRINNELL,
CENTRAL, STAR, VIKING OR AUTOMATIC SPRINKLER CORP. OF AMERICA. SEMI-RECESSED
PENDANT STYLE WITH CHROME FINISH BODY AND ESCUTCHEON IN AREAS WITH LAY-IN
CEILINGS, WHITE FLUSH CONCEALED TYPE IN GYPSUM BOARD CEILINGS AND STANDARD BRASS
UPRIGHT STYLE IN EXPOSED AREAS. STANDARD 165 DEGREE RATING UNLESS SPECIFIED OR
REQUIRED FOR HIGHER TEMPERATURE AREAS.
PROVIDE WIRE CAGE GUARDS ON HEADS WHERE REQUIRED.
PROVIDE TWO (2) SPARE HEADS OF EACH TYPE USED, COMPLETE WITH NECESSARY TOOLS AND
STORAGE CABINET, PROPERLY MARKED, SECURED TO WALL IN SPRINKLER RISER ROOM OR
OTHER LOCATION AS SELECTED BY THE ARCHITECT.
WATER FLOW SWITCHES
PROVIDE WATER FLOW SWITCHES AS REQUIRED BY DESIGN WITH CONTACTS AND WITH AN
ADJUSTABLE TIME DELAY MECHANISM BETWEEN THE PADDLE OPERATED STEM AND THE ALARM
INITIATING CONTACT TO ABSORB BRIEF WATER MOVEMENTS DUE TO THE WIDE RANGE OF
WATER PRESSURE OR NUMEROUS SURGES.
WATER FLOW SWITCHES SHALL BE 24 VOLT, SINGLE PHASE, SHALL BE AN APPROVED TYPE,
CONFORMING TO THE RULES AND REGULATIONS OF ALL THE APPLICABLE LOCAL CODES OR
ANY OTHER CODES HAVING JURISDICTION.
CONTRACTOR SHALL WIRE THE WATER FLOW SWITCHES TO ALARM BELLS, OR HORNS AND
STROBES, INSIDE AND OUTSIDE, AND TO SUPERVISORY PANEL.
FLUSH OUT AND TEST SYSTEMS PER NFPA REGULATIONS.
DESIGN BASIS SHALL BE ORDINARY HAZARD. ALL WORK RELATED TO THE SPRINKLER SYSTEM
SHALL BE IN ACCORDANCE WITH THE FIRE INSURANCE UNDERWRITERS REQUIREMENTS AND
THE REQUIREMENTS OF N.F.P.A., AND LOCAL FIRE MARSHAL. BEFORE STARTING ANY WORK ON
THE SPRINKLER SYSTEM, THE CONTRACTOR SHALL SUBMIT A COMPLETE SET OF ENGINEERED
REPRODUCIBLE SPRINKLER PLANS BEARING THE APPROVAL OF THE FIRE INSURANCE
UNDERWRITER, THE ARCHITECT AND THE LOCAL FIRE MARSHAL.
SPRINKLER SYSTEM SHALL BE TESTED AT A WATER PRESSURE OF 200 PSIG FOR A PERIOD OF
TWO (2) HOURS AND SHALL HAVE ALL FACILITIES FOR PROPER DRAINAGE AND ANY NECESSARY
TEST VALVES, ORIFICES, OR EQUIPMENT REQUIRED BY AUTHORITIES HAVING JURISDICTION.
UPON COMPLETION OF THE SYSTEM AND ON POSSESSION OF PREMISES, THE CONTRACTOR
SHALL SUBMIT A WRITTEN CERTIFICATE TO THE OWNER FROM THE UNDERWRITER STATING
THAT THE SYSTEM WAS INSPECTED AND APPROVED.
COORDINATE AND ADVISE THE ELECTRICAL CONTRACTOR OF ELECTRICAL REQUIREMENTS FOR
ALARMS, FLOW SWITCHES, TAMPER SWITCHES, GONGS, ETC. ALL ELECTRICAL WORK REQUIRED
MUST BE INCLUDED IN THE BASE BID.
FIRE PROTECTION SPECIFICATIONS GENERAL