abbreviations equipment lighting signal - … · ttc telephone terminal cabinet ttb telephone...
Post on 27-Jul-2018
212 Views
Preview:
TRANSCRIPT
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
S S
SS
S S
SS
SS
ABBREVIATIONS
NOTE
NL NIGHT LIGHT CIRCUIT
PUBLIC ADDRESS
TRANSFER SWITCHXFSW
TRANSFORMERXFMR
WEATHER PROOFWP
WATTSW
VAPOR PROOFVP
VOLT AMPERESVA
VOLTAGEV
UNINTERRUPTABLE POWER SUPPLYUPS
UNDERGROUNDUG
TYPICALTYP
TELEVISIONTV
TELEPHONE TERMINAL CABINETTTC
TELEPHONE TERMINAL BOARDTTB
TAMPERPROOFTP
TIME DELAYTD
SWITCHSW
SOLENOID VALVESV
STARTERSTR
SUB-DISTRIBUTION PANELSDP
POWERPWR
POLYVINYL CHLORIDE CONDUITPVC
PANELBOARDPNL
POWER FACTORPF
PHOTO ELECTRIC CELLPE
PA
NOT IN CONTRACTNIC
MANUAL TRANSFER SWITCHMTS
MERCURY VAPORMV
MAIN LUGS ONLYMLO
METAL HALIDEMH
MECHANICALMECH
MAIN DISTRIBUTION PANELMDP
MOTOR CONTROL CENTERMCC
MAIN CIRCUIT BREAKERMCB
MINIMUM CIRCUIT AMPSMCA
MASTER ANTENNA TELEVISIONMATV
LOW VOLTAGELV
LIGHTINGLTG
LIGHTNING ARRESTORLA
KILOVOLT AMPS REACTIVEKVAR
KILOVOLT AMPKVA
KILOVOLTKV
KILOWATT HOURKWH
KILOWATTKW
JUNCTION BOXJB
INCANDESCENTINC
ISOLATED GROUNDIG
HERTZHZ
HIGH VOLTAGEHV
HIGH PRESSURE SODIUMHPS
HORSEPOWERHP
GROUNDGRD
GALVANIZED RIGID CONDUITGRC
GROUND FAULT CIRCUIT INTERRUPTERGFCI
GROUND FAULT INTERRUPTERGFI
GROUND FAULT PROTECTIONGFP
INSTALLED BY OWNER
FURNISHED BY OWNERFOIO
INSTALLED BY CONTRACTOR
FURNISHED BY OWNERFOIC
INSTALLED BY CONTRACTOR
FURNISHED BY CONTRACTORFCIC
FLUORESCENTFLUOR
FULL LOAD AMPSFLA
FIRE ALARMFA
ELECTRIC WATER COOLEREWC
EMERGENCY POWER OFFEPO
EXPLOSION PROOFEP
ELECTRIC METALLIC TUBINGEMT
EMERGENCYEMERG
DOWNDN
COPPERCU
CURRENT TRANSFORMERCT
CEILINGCLG
CIRCUITCKT
CLOSED CIRCUIT TELEVISIONCCTV
CONDUITC
CIRCUIT BREAKERCB
AUTOMATIC TRANSFER SWITCHATS
ARCHITECT / ARCHITECTURALARCH
ALUMINUMAL
AMPERE (AMP)A
ABOVE FINISHED FLOORAFF
THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY
APPEAR ON THIS SHEET THAT DO NOT APPEAR ON THE DRAWINGS.
DESIGNATION SYMBOLS
123
1
XE
NEW, CONNECT TO
EQUIPMENT DESIGNATOR SEE SCHEDULE.
NOTE
EXISTING TO BE RELOCATED, FUTURE
EXISTING TO REMAIN, EXISTING TO BE REMOVED
CN
---
FR
EQUIPMENT LIGHTING
NOTES:
GENERAL NOTES:
FINISHED FLOOR
CEILING
MOUNTING HEIGHTS
FIRE
6"
MIN 12"MIN 6"
18"
36"
40"
48"
90"
96"
1 OCCUPANCY SENSOR
FIRE ALARM STROBES
FIRE ALARM PULL STATION
LIGHT SWITCH
CARD READER
WALL PHONE
ABOVE COUNTER RECEPTACLE
RECEPTACLE
DATA OUTLET
2
3
4
5
6
7
8
9
1
2
34
5
6 7
8 9
1. LOCATE ALL FIRE ALARM DEVICES PER CODE.
LOCATE ALL ACCESSIBLE SWITCHES PER ADA GUIDELINES.
FIELD COORDINATE ALL ABOVE COUNTER DEVICES WITH
MILLWORK CONTRACTOR.
IF APPLICABLE, TELCOM CONSULTANTS DRAWINGS TAKE
PRECEDENCE OVER THIS DETAIL FOR TELCOM DEVICES.
2.
3.
4.
XXXXX
X
XXX
ONE-LINE
CIRCUIT BREAKER
SWITCH, FUSED SWITCH
AUTOMATIC SWITCH
METER
PANEL
FEEDER CALLOUT
FAULT CURRENT CALLOUT
BUSS
G GENERATOR
M
POWER
FF
FF
K
E
T
AIM
E
C
PH
PP
FF
SS
F
TV
V
F
F
FS TS
SIGNAL
FIRE ALARM
TELECOMMUNICATIONS
SECURITY
SECURITY ELECTRONIC SENSOR
CARD KEY READER STATION
MANUAL EMERGENCY SECURITY STATION
FIRE ALARM: VISUAL
WALL OUTLET: MICROPHONE, INTERCOM, AUDIO JACK
THERMOSTAT
FIRE ALARM SPEAKER: WALL, CEILING
FIRE ALARM: HORN; HORN W/VISUAL; CEILING MOUNTED
FIRE ALARM: BELL; BELL W/VISUAL
WALL OUTLET: VOLUME CONTROL
WALL OUTLET: TELEPHONE, EMERGENCY TELEPHONE, DATA
MASTER ANTENNA TV OUTLET
SYSTEM CLOCK: WALL, CEILING
ELECTRIC DOOR LOCK, CONTACT
MAGNETIC DOOR HOLDER, CLOSER
SPEAKER: WALL, CEILING
DUCT DETECTOR, TYPE AS NOTED
DETECTOR: IONIZATION, HEAT, PHOTOELECTRIC
SPRINKLER SYSTEM SWITCH: FLOW, TAMPER
MANUAL FIRE ALARM STATION
CCTV CAMERA
FIREMANS PHONE JACK
WALL OUTLET: COMBINATION TELEPHONE/DATAD,U,R
CABLE/JACK QUANTITY
DETECTOR: BEAM
ELECTRICAL EQUIPMENT (GENERIC)
TRANSFORMER
CABINET: SURFACE, RECESSED
PANELBOARD: SURFACE, RECESSED
GROUND PAD
GROUND ROD, IN TEST WELL
DISCONNECT SWITCH
PLYWOOD BACKBOARD
ATS SWITCH
CONDUIT ROUTING WITH PULL BOX
OS
PE
OS
PE
J
LV P
MK
3 4
S
A
WALL SWITCH: KEY LOCK, MOMENTARY
WALL SWITCH: 3 WAY, 4 WAY
DESIGNATES LUMINAIRE TYPE (SEE LUMINAIRE SCHEDULE)
BOLLARD
FLUORESCENT LUMINAIRE: BARE LAMP
WALL LUMINAIRE: SURFACE, RECESSED
POLE LIGHT: LUMINAIRES AS SHOWN
TRACK WITH HEADS LOCATED
WALL WASHER: SURFACE, RECESSED
PHOTOELECTRIC CELL: WALL MOUNTED, CEILING MOUNTED
WALL SWITCH: TIMER, MANUAL DIMMER
WALL SWITCH: LOW VOLTAGE, PILOT
WALL SWITCH: 1 POLE, SENTRY SWITCH
EMERGENCY BATTERY LIGHT: HEADS AS SHOWN
EXIT LIGHT: CEILING, WALL (ARROWS AS SHOWN)
DESIGNATES LIGHT ON EMERGENCY CIRCUIT
FLUORESCENT LUMINAIRE: SURFACE, RECESSED
FLUORESCENT LUMINAIRE: WALL MOUNTED
CEILING LUMINAIRE: SURFACE, RECESSED
DT
CEILING LUMINAIRE: PENDANT MOUNTED
PENDANT LUMINAIRE: SMALL PROFILE, WIDE PROFILE
NL DESIGNATES NIGHT LIGHT CIRCUIT
OCCUPANCY SENSOR: CEILING OR WALL MOUNTED
REFERENCE FLOOR PLANS FOR TYPE OF SENSOR
UNI-STRUT LIGHTING ASSEMBLY
SC
J
OL MOTOR STARTER: MANUAL, MAGNETIC, COMBINATION
WIRING CONCEALED IN CEILING OR WALL
WIRING CONCEALED IN FLOOR OR UNDERGROUND
SURFACE OUTLET STRIP: DIMENSION AS SHOWN
WALL RECEPTACLE: EMERGENCY, QUADPLEX
WALL RECEPTACLE: SINGLE, DUPLEX
PUSH BUTTON STATION
JUNCTION BOX
DENOTES RECEPTACLE ABOVE COUNTER
SPECIAL PURPOSE OUTLET AS NOTED, EMERGENCY
CEILING RECEPTACLE: DUPLEX, QUADPLEX
FLUSH IN-FLOOR OUTLET: DUPLEX, QUAD
MOTOR CONNECTION
CONTACTOR, SOLENOID
INDICATES INSULATED GREEN GROUND WIRE
HOME RUN DESTINATION SHOWN
CONDUIT ELL: UP, DN.
WALL RECEPTACLE: ISOLATED GROUND
FIRE RATED FLOOR POKE-THRU
J
I
UL UL 924 DEVICE
R LIGHTING RELAY
PP POWER PACK
B BALLAST (DIMMING)
EMERGENCYEM
KEYBOARD/DISPLAY UNITKDU
FIRE ALARM CONTROL PANELFACP
BOTTOM OF CABLE TRAYBOCT
FC
CABLE TRAY
45"
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:25:4
4 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SY
MB
OLS
, LE
GE
ND
S A
ND
AB
BR
EV
IAT
ION
S -
ELE
CT
RIC
AL
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E001
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
Tag Description Size Watts Lamp(s) Ballast Voltage Product Mounting Finish Notes
L1-4SUSPENDED LED LINEARDIRECT/INDIRECT
NOMINAL 8INCH WIDE X2 INCH DEEPX FOUR FEET
LONG
41
LED, 4000K4500
DELIVEREDLUMENS PERFOUR FOOT
SECTION
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
CORELITE JAULUM SERIES,PEERLESS STAPLE SERIES, LEDALITE
SYNC SERIES, AXISSURROUNDLIGHT SERIES
SUSPENDEDAIRCRAFT CABLE
STANDARD ASSELECTED BYARCHITECT
NOMINAL DISTRIBUTION IS TO BE70% INDIRECT 30 % DIRECT.
L1-8SUSPENDED LED LINEARDIRECT/INDIRECT
NOMINAL 8INCH WIDE X2 INCH DEEPX EIGHT FEET
LONG
82
LED, 4000K4500
DELIVEREDLUMENS PERFOUR FOOT
SECTION
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
CORELITE JAULUM SERIES,PEERLESS STAPLE SERIES, LEDALITE
SYNC SERIES, AXISSURROUNDLIGHT SERIES
SUSPENDEDAIRCRAFT CABLE
STANDARD ASSELECTED BYARCHITECT
NOMINAL DISTRIBUTION IS TO BE70% INDIRECT 30 % DIRECT.
L2 RECESSED LENSED LED4 INCH X 4
INCH X 4 FEETLONG
32
LED 4000 K3000 LUMENS
PER FOURFOOT
SECTION
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
AXIS BEAM SERIES, NULITE RT4SERIES , NEO RAY STRAIGHT AND
NARROW SERIESCEILING RECESSED
STANDARD ASSELECTED BYARCHITECT
FLANGELESS INSTALLATION
L2ASAME AS TYPE L2 EXCEPT VERTICALWALL MOUNT - FLANGELESS
4 INCH X 4INCH X 4 FEET
LONG32
LED 4000 K3000 LUMENS
PER FOURFOOT
SECTION
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
AXIS BEAM SERIES, NULITE RT4SERIES , NEORAY STRAIGHT AND
NARROW SERIESCEILING RECESSED
STANDARD ASSELECTED BYARCHITECT
FLANGELESS VERTICAL WALLMOUNT INSTALLATION
L3A RECESSED LED CIRCULAR CLOUD2 FOOT
DIAMETER29 1400 LUMENS
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
PRUDENTIAL P9000 SERIES, MARKLIGHTING MAGELLAN SERIES
CEILING RECESSEDSTANDARD ASSELECTED BYARCHITECT
L3B RECESSED LED CIRCULAR CLOUD4 FOOT
DIAMETER89 5500 LUMENS
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
PRUDENTIAL P9000 SERIES, MARKLIGHTING MAGELLAN SERIES
CEILING RECESSEDSTANDARD ASSELECTED BYARCHITECT
L4 RECESSED LED 2X22X2 FEETSQUARE
37LED, 3700LUMENS
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
LITHONIA 2ALL SERIES, CORELITEENCOUNTER SERIES LEDALITE
PURE FX SERIES, AXIS DAYCEILING RECESSED
STANDARD ASSELECTED BYARCHITECT
L4ARECESSED LED 2X2 FOOD SERVICERATED
2X2 FEETSQUARE
45LED, 4400LUMENS
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
KURTZON FP SERIES CEILING RECESSEDSTANDARD ASSELECTED BYARCHITECT
FOOD SERVICE RATED
L5 RECESSED LED DOWNLIGHT6 INCHROUND
APERTURE28 1800 LUMENS
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
GOTHAM EVO SERIES PORTFOLIOLD6A SERIES, INDY
CEILING RECESSEDCLEAR ALZAKREFLECTOR
L6 SURFACE MOUNTED LINEAR LED
NOMINAL 8INCH WIDE X
FOUR FEETLONG
40 4000 LUMENS 0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
LITHONIA STL SERIES, OR PRE-BIDAPPROVED
SURFACE CEILINGSTANDARD ASSELECTED BYARCHITECT
L7SURFACE OR SUSPENDED LEDLENSED STRIP
NOMINAL 3INCH WIDE X4 FEET LONG
32 1800 LUMENS 0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
LITHONIA ZL2N SERIES, METALUXSNLED SERIES
SURFACE CEILING,OR CHAIN HUNG
STANDARD ASSELECTED BYARCHITECT
L8 LINEAR LED HIGHBAY
NOMINAL 4INCH WIDE X
16 FOOTROW AND 4FOOT LONGINDIVIDUAL
47 PERFOURFEET
3500 LUMENSPER FOUR FEET
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
LITHONIA PTSNL SERIESSURFACE TO
BOTTOM CHORDOF TRUSS
STANDARD ASSELECTED BYARCHITECT
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:25:4
6 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
LU
MIN
AIR
E S
CH
ED
ULE
1 O
F 2
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E002
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
Tag Description Size Watts Lamp(s) Ballast Voltage Product Mounting Finish Notes
L10 LED CYLINDER
16 HIGH X 8INCH
DIAMETERWITH 6 INCH
APERTURE
996000 LUMEN60 DEGREE
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
GOTHAM INCITO, PORTFOLIOLCR8A,.
SURFACESTANDARD ASSELECTED BYARCHITECT
L10A LED CYLINDER
16 HIGH X 8INCH
DIAMETERWITH 6 INCH
APERTURE
996000 LUMEN45 DEGREE
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
GOTHAM INCITO, PORTFOLIOLCR8A,.
SURFACESTANDARD ASSELECTED BYARCHITECT
L10B LED CYLINDER
16 HIGH X 8INCH
DIAMETERWITH 6 INCH
APERTURE
994000 LUMEN30 DEGREE
0-10 DIMMINGELECTRONIC
UNIVERSALVOLTAGE
GOTHAM INCITO, PORTFOLIOLCR8A,.
SURFACESTANDARD ASSELECTED BYARCHITECT
L11 LED STEP LIGHT5 1/4 X 2 7/8 X
42.1
36 LUMEN3000K
ELELCTRONICNON DIM
120 VBEGA 1325 LED OR PRE BID
APPROVEDRECESSED WALL
STANDARD ASSELECTED BYARCHITECT
L12 RECESSSED SMALL DIAMETER2 1/2 INCH
DIAMETER X 4INCH DEEP
3 WATT120 LUMEN
3000K ELECTRONIC 120/277V
BRUCK LEDRA 12 WITH J-BOXAND DRIVER
RECESSED CEILINGIN DISPLAY CASE
MATTE CHROME
L13 LINEAR WET LOCATION LEDNOMINAL 8
INCH WIDE X4 FEET LONG
39 WATT2975 LUMEN
4100 K ELECTRONIC 120/277V
LITHONIA VAP SERIES, OR PRE BIDAPPROVED
CEILING MOUNTOR SUSPENDED
STANDARD ASSELECTED BYARCHITECT
L14SUSPENDED LED CIRCULARDIRECT/INDIRECT
NOMINAL 5INCH HIGH X
2 FOOTDIAMETER
36 WATT270 LUMENSPER FOOT
REMOTE DRIVERELECTRONIC
120/277V DELRAY CYLINDRO IIISUSPENDED
AIRCRAFT CABLE
STANDARD ASSELECTED BYARCHITECT
L14 ASUSPENDED LED CIRCULARDIRECT/INDIRECT
NOMINAL 5INCH HIGH X
4 FOOTDIAMETER
54 WATTREMOTE DRIVER
ELECTRONIC120/277V DELRAY CYLINDRO III
SUSPENDEDAIRCRAFT CABLE
STANDARD ASSELECTED BYARCHITECT
X UNIVERSAL LED EXIT SIGN 13-7/8 X 8.5 3 WATT GREEN LED ELECTRONIC 120/277VLITHONIA EXTREME SERIES,UNIVERSAL MOUNT WITH
BATTERY
STANDARD ASSELECTED BYARCHITECT
WHITE WITH GREEN LETTERS
X1 WEATHERPROOF EXIT SIGN 13-7/8 X 8.5 3 WATT GREEN LED ELECTRONIC 120/277VLITHONIA EXTREME SERIES,UNIVERSAL MOUNT WITH
BATTERY
STANDARD ASSELECTED BYARCHITECT
WEATHERPROOF ENCLOSURE
S1 SITE AREA LED POLE LIGHT20 INCH
DIAMETER135 14000 LUMEN
DUAL DRIVERFOR LIGHT
REDUCTION
UNIVERSALVOLTAGE
LITHONIA OMERO SERIES TYPE VDISTRIBUTION, OR PRE BID
APPROVED
STANDARD ASSELECTED BYARCHITECT
18 FOOT POLE ON FLUSH BASE SEEDETAIL
S2 SITE AREA LED POLE LIGHT20 INCH
DIAMETER135 14000 LUMEN
DUAL DRIVERFOR LIGHT
REDUCTION
UNIVERSALVOLTAGE
LITHONIA OMERO SERIES TYPE IVDISTRIBUTION, OR PRE BID
APPROVED
STANDARD ASSELECTED BYARCHITECT
18 FOOT POLE ON FLUSH BASE SEEDETAIL
S3 SITE LED LIGHT COLUMN8 INCH WIDEX 8 FEET TALL
401100 LUMEN
4000K ELECTRONIC 120/277V
BEGA 7844 SERIES, OR PRE BIDAPPROVED
STANDARD ASSELECTED BYARCHITECT
FLUSH BASE
S3ASAME AS TYPE S3 EXCEPT 5 FOOTINSTALLED HEIGHT
8 INCH WIDEX 8 FEET TALL
401100 LUMEN
4000K ELECTRONIC 120/277V
BEGA 7844 SERIES, OR PRE BIDAPPROVED
STANDARD ASSELECTED BYARCHITECT
FLUSH BASE
S4 SITE LED BOLLARD8 INCH
DIAMETER X36 INCH HIGH
12435 LUMEN
3500K ELECTRONIC 120/277V
SELUX NOTCH, OR PRE BIDAPPROVED
STANDARD ASSELECTED BYARCHITECT
SEE BASE DETAIL
S5WALL MOUNTED LED BUILDINGMOUNTED
16 INCH WIDEX 8 INCH
HIGH24
2000 LUMENTYPE III 4000 K
ELECTRONIC 120/277VLITHONIA WST, OR PRE BID
APPROVED
STANDARD ASSELECTED BYARCHITECT
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:25:4
7 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
LU
MIN
AIR
E S
CH
ED
ULE
2 O
F 2
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E003
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
MATCHLINE
S3AS3AS3A
S3A
S3A
S3A
S3A
S12S12
S22 S22
S3A
S3A
S3A
S4
S4
S4
S4
S4
S4
3
S3A
S3A
S3A
54
6
7
11
1-1/2"C 1-1/2"C
21D1:38
21D1:40,42
rsa04
rsa05
rsa05
rsa05
rsa05
rsa05
rsa05
rsa01rsa02
rsa03
rsa03
rsa03
rsa03
rsa03
rsa03
rsa01rsa02
rsa01rsa02
rsa01rsa02
rsa03
rsa03 rsa03 rsa03
rsa06
rsa06
rsa06
8
9
10
S4rsa05
S4 rsa05
S4rsa05
S4rsa05
S4
rsa05
S4
rsa05
1 1
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:25:5
4 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SIT
E P
LA
N -
ELE
CT
RIC
AL
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E010
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1" = 20'-0"1 SITE PLAN - ELECTRICAL
NOTES:
1. PROVIDE 1-1/2" CONDUIT TO MDF FOR SECURITY CAMERAWIRING BY OTHERS.
2. PROVIDE (2) RELAYS PER POLE FOR LIGHT REDUCTION BASEDON TIME CLOCK INPUT.
3. TRANSFORMER VAULT. UTILITY VAULT CO MODEL 712-LAREFERENCE EWEB DRAWINGS FOR ADDITIONAL INFORMATION.
4. PROVIDE ELECTRICAL CONNECTION TO 1/2 HP PUMP IN DCDBFP VAULT.
5. PROVIDE ELECTRICAL CONNECTION (2-#4AWG CU AND 1-#6AWG CU GRD) TO EACH OF THE TWO (2) 1500 WATT HEATERS INRP BFP VAULT.
6. MONUMENT SIGN. PROVIDE 1 INCH CONDUIT FROM SIGN TOMDF. CONDUIT TO BE USED FOR DATA CABLING TO SIGN.CABLING BY OTHERS.
7. EXISTING IRRIGATION WELL CONTROLLER TO BE RELOCATED.DISCONNECT TEMPORARY ELECTRICAL CONNECTION FROMEXISTING HOWARD ELEMENTARY SCHOOL AND FROMCONTROLLER TO WELL PUMP.
8. IRRIGATION WELL PUMP.
9. NEW LOCATION FOR IRRIGATION WELL CONTROLLER.PROVIDE NEW ELECTRICAL CONNECTION.
10. PROVIDE 1 INCH CONDUIT FOR CONTROL WIRING AND (2) 10AWG CONDUCTORS WITH (1) 10 AWG GROUND IN A 1" CONDUITFOR POWER.
NO
RT
H
GENERAL NOTES:
A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANTTO REPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS.NOT EVERY BEND, OFFSET, PULLBOX, ETC, IS SHOWN.CONTRACTOR SHALL PROVIDE ALL WORK REQUIRED FOR ACOMPLETE INSTALLATION.
B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTINGAND NEW UTILITIES.
C. ALL BRANCH CIRCUITING AT BUILDING EXTERIOR AND SITESHALL BE #10AWG MINIMUM, UNLESS OTHERWISE NOTED.
D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCHCIRCUIT.
E. REFER TO LIGHTING RELAY SCHEDULE ON SHEET E703 FORADDITIONAL INFORMATION.
F. PROVIDE NO MORE THAN (6) CURRENT CARRYINGCONDUCTORS (INCLUDING NEUTRAL) PER HOMERUN.
G. COORDINATE INSTALLATION OF NEW ELECTRICAL SERVICEWITH EWEB.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
3
2
6
1
4
X1
X1
7
7
rsa07
rsa07 rsa07 rsa07rsa07
rsa07S3A
S3A S3A S3AS3A
S3A
X1
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:26:0
6 P
MC
:\R
evi
t Loca
l File
s\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.
hansen.r
vt
SIT
E P
LA
N -
ELE
CT
RIC
AL
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E011
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1" = 20'-0"1 SITE PLAN - ELECTRICAL
NOTES:
1. EXISTING 5 INCH CONDUIT WEST OF THIS AREA INSTALLEDUNDER KELLY MIDDLE SCHOOL TRACK PROJECT. CONDUIT TO BEUTILIZED FOR NEW SERVICE TO HOWARD ELEMENTARY SCHOOL.EXTEND CONDUIT AS INDICATED.
2. SECTIONALIZING VAULT. PROVIDE UTILITY VAULT CO MODEL575-FUSE-PCORP. REFERENCE EWEB DRAWINGS FOR ADDITIONALINFORMATION.
3. PROVIDE ONE (1) 3 INCH CONDUIT.
4. TRANSFORMER VAULT. PROVIDE UTILITY VAULT CO MODEL 712-LA. REFERENCE EWEB DRAWINGS FOR ADDITIONALINFORMATION.
5. NOT USED.
6. LIGHTING ALLOWANCE OF $1000.00 FOR PLAY STRUCTURE.PROVIDE RELAY BASED CONTROL WITH MANUAL OVERRIDESWITCH IN P/E OFFICE. VERIFY EXACT LOCATION. CONFIGUREFOR PE CELL ON/TIME CLOCK OFF OPERATION.
7. PROVIDE 1 INCH CONDUIT FROM CENTER GATE POST TO MDFFOR ACCESS CONTROL CABLING.
NO
RT
H
GENERAL NOTES:
A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANT TOREPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS. NOTEVERY BEND, OFFSET, PULLBOX, ETC, IS SHOWN. CONTRACTORSHALL PROVIDE ALL WORK REQUIRED FOR A COMPLETEINSTALLATION.
B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTINGAND NEW UTILITIES.
C. COORDINATE INSTALLATION OF NEW ELECTRICAL SERVICEWITH EWEB.
D. ALL BRANCH CIRCUITING AT BUILDING EXTERIOR AND SITE SHALLBE #10AWG MINIMUM, UNLESS OTHERWISE NOTED.
E. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCHCIRCUIT.
F. REFER TO LIGHTING RELAY SCHEDULE ON SHEET E703 FORADDITIONAL INFORMATION.
G. PROVIDE NO MORE THAN (6) CURRENT CARRYINGCONDUCTORS (INCLUDING NEUTRAL) PER HOMERUN.
H. PROVIDE CONNECTION TO EXIT SIGNS FROM THE NEARESTEMERGENCY CIRCUIT WITH AN UNSWITCHED LEG.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
21
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:26:1
1 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SIT
E P
LA
N -
ELE
CT
RIC
AL
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E012
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1" = 20'-0"1 SITE PLAN - ELECTRICAL
NOTES:
1. APPROXIMATE LOCATION OF EXISTING EWB VAULT NO. V4052.
2. EXISTING 5 INCH CONDUIT INSTALLED UNDER KELLY MIDDLESCHOOL TRACK PROJECT. CONDUIT TO BE UTILIZED FOR NEWSERVICE TO HOWARD ELEMENTARY SCHOOL.
NO
RT
H
GENERAL NOTES:
A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANTTO REPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS.NOT EVERY BEND, OFFSET, PULLBOX, ETC, IS SHOWN.CONTRACTOR SHALL PROVIDE ALL WORK REQUIRED FOR ACOMPLETE INSTALLATION.
B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTINGAND NEW UTILITIES.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
CAFETERIA
A103
A BEXIT
ENTRY
EXIT
TRAYRETURN
ENTRY
CAFETERIA
A103
A BEXIT
ENTRY
EXIT
TRAYRETURN
ENTRY
CLASSROOM
B127
CLASSROOM
B126
COMMONS
B130
CLASSROOM
B129
CLASSROOM
B131
LIFE SKILLS
B125RECEPTION
B100
VESTIBULE
A100
CLASSROOM
B146
COMMONS
B145
MULTIPURPOSE
B149
CLASSROOM
B148CLASSROOM
B150
CLASSROOM
B144
CLASSROOM
C113
MULTIPURPOSE
C112
CLASSROOM
C111
CLASSROOM
C109
COMMONS
C108
CLASSROOM
C107
BOILER
A119
BLDG STORAGE
A117
COMMUNITY ROOM
A102
GIRLS
B142
TOILET
B112
GIRLS
B123
MDF
B120
HALLWAY
B128
TOILET
B104
BOYS
B141
GIRLS
C104
PE OFC/STG
A114
CUSTODIAL
A116
ELEC
A118
BOYS
A109
GIRLS
A110
FAMILY TOILET
A107
TBL STORAGE
A105
GYM
A111
MUSIC ROOM / STAGE
A113
LOBBY
A101
LOST AND FOUND
A115
CUST
A104C
PRINCIPAL
B102
CONFERENCE
B110
SECRETARY
B101
QUIET
B105
CLOSET
B109
VOLUNTEER
B117
SENSORY ROOM
B115
LACTATION RM
B111
HEALTH
B106
OFFICE
B107
CUST
B138
IDF
C101
STAFF TOILET
C103
STAFF TOILET
B140
SMALL GROUP
B134
OFFICE
B136
BOYS
C105
SOR
C102
SMALL GROUP
B116
MOTOR SKILLS
B114
WORKROOM
B113
HEALTH TOILET
B108
BOYS
B122
SOR
B139
CAFETERIA
A103
KITCHEN
A104
PE CIRCULATION
A106 CUST
A112
STAFF ROOM
B103
HALLWAY
B119
ELEVATOR
B118
HALLWAY
B124
CHANGING TOILET
B125C
MEDIA CENTER
B132
MEDIA WORK RM
B133
STAIR
B132B
STAIR
B132A
HALLWAY
B143
HALLWAY
B147HALLWAY
C100
HALLWAY
C106
HALLWAY
C110
SOR
B121
KITCHEN
A104D
CHANGING
B125D
HALLWAY
B137
STAIR
C114
RAMP
A121
STAIR
B151
STAIR
B128A
HALL
A106B
HALLWAY
B137STORY COVE
B135
WF
A120
H
1 2
3
4
5 68
9 10 12 13 14 15
N
S
LL
C
R
Q
M
E
F
G
D
B
6.2 6.8 8.2 11
B.3
B.7 B.8
D.9
G.1
H.2
J
K
P
4.3
P.7
13.67.8
B.5
0.911.9
5
(1) 1 INCH C.
1
(3) 2 INCH C.
1
(2) 2 INCH C.
(4) 2 INCH C.
(4) 2 INCH C.
(2) 2 INCH C.
4
2
2
2
4
4
3
5.41.9
A
B
C
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:26:1
7 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
OV
ER
ALL E
LE
CT
RIC
AL P
LA
N -
TE
LE
CO
MM
UN
ICA
TIO
NS
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E013
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
NOTES:
1. COORDINATE EXACT LOCATION OF CONDUIT STUB UPS WITHTELECOMMUNICATIONS DRAWINGS.
2. (1) 1"C STUB UP IN CABINET VOID.
3. REFERENCE SHEET E113 FOR CONTINUATION.
4. STUB UP IN WALL BASE. REFER TO TECHNOLOGY DRAWINGS FORCONTINUATION.
5. REFERENCE SHEET E411 AND E412 FOR CONTINUATION.
1/16" = 1'-0"1 OVERALL ELECTRICAL PLAN - TELECOMMUNICATIONS
NO
RT
H
GENERAL NOTES:
A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANTTO REPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS.NOT EVERY BEND, OFFSET, PULLBOX, ETC, IS SHOWN.CONTRACTOR SHALL PROVIDE ALL WORK REQUIRED FOR ACOMPLETE INSTALLATION.
B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTINGAND NEW UTILITIES.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
CAFETERIA
A103
A BEXIT
ENTRY
EXIT
TRAYRETURN
ENTRY
CAFETERIA
A103
A BEXIT
ENTRY
EXIT
TRAYRETURN
ENTRY
Conduit ID From Equipment To Equipment
N1 MDP 41A1
N2 MDP 41C1
N3 MDP 42C1
N4 MDP 42A1
N5 MDP CHILLER
N6 MDP ELEVATOR
N7 MDP 4K1
N8 SDP 2K1
N9 SDP 21A1
N10 SDP 21A2
N11 SDP 21B1
N12 SDP 21C1
N14 SDP 22A1
N15 SDP 22B1
N16 SDP 22C1
N19 SDP GYMNASIUM
L1 41LSD1 42LSA1
L2 41LSD1 42LSC1
S1 STDP IDF-1
S2 STDP IDF-2
S3 STDP MDF
S4 STDP 21SBK1
S5 STDP 21SBA1
CLASSROOM
B127
CLASSROOM
B126
COMMONS
B130
CLASSROOM
B129
CLASSROOM
B131
LIFE SKILLS
B125RECEPTION
B100
VESTIBULE
A100
CLASSROOM
B146
COMMONS
B145
MULTIPURPOSE
B149
CLASSROOM
B148CLASSROOM
B150
CLASSROOM
B144
CLASSROOM
C113
MULTIPURPOSE
C112
CLASSROOM
C111
CLASSROOM
C109
COMMONS
C108
CLASSROOM
C107
BOILER
A119
BLDG STORAGE
A117
COMMUNITY ROOM
A102
GIRLS
B142
TOILET
B112
GIRLS
B123
MDF
B120
HALLWAY
B128
TOILET
B104
BOYS
B141
GIRLS
C104
PE OFC/STG
A114
CUSTODIAL
A116
ELEC
A118
BOYS
A109
GIRLS
A110
FAMILY TOILET
A107
TBL STORAGE
A105
GYM
A111
MUSIC ROOM / STAGE
A113
LOBBY
A101
LOST AND FOUND
A115
CUST
A104C
PRINCIPAL
B102
CONFERENCE
B110
SECRETARY
B101
QUIET
B105
CLOSET
B109
VOLUNTEER
B117
SENSORY ROOM
B115
LACTATION RM
B111
HEALTH
B106
OFFICE
B107
CUST
B138
IDF
C101
STAFF TOILET
C103
STAFF TOILET
B140
SMALL GROUP
B134
OFFICE
B136
BOYS
C105
SOR
C102
SMALL GROUP
B116
MOTOR SKILLS
B114
WORKROOM
B113
HEALTH TOILET
B108
BOYS
B122
SOR
B139
CAFETERIA
A103
KITCHEN
A104
PE CIRCULATION
A106 CUST
A112
STAFF ROOM
B103
HALLWAY
B119
ELEVATOR
B118
HALLWAY
B124
CHANGING TOILET
B125C
MEDIA CENTER
B132
MEDIA WORK RM
B133
STAIR
B132B
STAIR
B132A
HALLWAY
B143
HALLWAY
B147HALLWAY
C100
HALLWAY
C106
HALLWAY
C110
SOR
B121
KITCHEN
A104D
CHANGING
B125D
HALLWAY
B137
STAIR
C114
RAMP
A121
STAIR
B151
STAIR
B128A
HALL
A106B
HALLWAY
B137STORY COVE
B135
WF
A120
H
1 2
3
4
5 68
9 10 12 13 14 15
NN
SS
LL
C
R
QQ
M
E
FF
G
D
B
6.2 6.8 8.2 11
B.3
B.7 B.8
D.9
G.1
H.2
J
K
P
4.3
P.7
13.6
E.7
7.8
B.5
0.911.9
N7
N5
N2
N3
S4
N8
N16
L2
N12
S2N11
S1
N15
N6
N19
N4
N14
L1
1
N10
S5
N1
N9
S3
2
11
5.41.9
TO CHILLER
A
B
C
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:26:2
4 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
OV
ER
ALL E
LE
CT
RIC
AL P
LA
N -
PO
WE
RE
UG
EN
E S
CH
OO
L D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E014
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1/16" = 1'-0"1 OVERALL ELECTRICAL PLAN - POWER
NOTES:
1. CONDUITS TO BE ROUTED TO PANELS ON SECOND FLOOR.
2. STUB INTO ELEVATOR MACHINE ROOM.
GENERAL NOTES:
A. ALL UNDER SLAB CONDUITS TO BE COORDINATED WITH OTHER TRADES.
B. REFERENCE FLOOR PLANS FOR ADDITIONAL INFORMATION.
C. CONDUIT ROUTING SHOWN ON DRAWINGS IS DIAGRAMMATIC. CONDUITS TOBE ROUTED IN A DIRECT LINE. REFERENCE SPECIFICTION FOR ADDITIONALINFORMATION.
NONE2 CONDUIT SCHEDULE
NO
RT
H
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
3
4
1
2
(E) 3 INCH C.
(2) 4 INCH C.
(2) 2 INCH C.(2) 4 INCH C.
(2) 2 INCH C.(2) 4 INCH C.
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:26:3
9 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
OV
ER
ALL S
ITE
PLA
NT
ELE
CO
MM
UN
ICA
TIO
NS
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E015
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1" = 30'-0"1 OVERALL SITE PLAN - TELECOMMUNICATIONS
NOTES:
1. UTILITY VAULT CO. MODEL TA25 VAULT. INTERCEPT CONDUIT FROM KELLYMIDDLE SCHOOL.
2. COORDINATE CONDUIT STUB UP LOCATIONS WITH TELECOMMUNICATIONSDRAWINGS.
3. UTILITY VAULT CO. MODEL TA25 VAULT.
4. STUB CONDUITS UP AT BASE OF POLE.
NO
RT
H
GENERAL NOTES:
A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANT TOREPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS. NOT EVERYBEND, OFFSET, PULLBOX, ETC, IS SHOWN. CONTRACTOR SHALL PROVIDEALL WORK REQUIRED FOR A COMPLETE INSTALLATION.
B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTING AND NEWUTILITIES.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
CAFETERIA
A103
A BEXIT
ENTRY
EXIT
TRAYRETURN
ENTRY
CAFETERIA
A103
A BEXIT
ENTRY
EXIT
TRAYRETURN
ENTRY
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
VESTIBULE
A100
BOILER
A119
BLDG STORAGE
A117
COMMUNITY ROOM
A102
PE OFC/STG
A114
CUSTODIAL
A116
ELEC
A118
BOYS
A109
GIRLS
A110
FAMILY TOILET
A107
TBL STORAGE
A105
GYM
A111
MUSIC ROOM / STAGE
A113
LOBBY
A101
LOST AND FOUND
A115
CUST
A104C
CAFETERIA
A103
KITCHEN
A104
PE CIRCULATION
A106
CUST
A112
KITCHEN
A104D
RAMP
A121
HALL
A106B
WF
A120
GFCI
GENERATORREMOTE
ANNUNCIATOR
PANEL 2K1
PANEL 21SBK1
GFCI
PANEL 4K1
/1 E115
E411
1
/1
E113
GFCI
GFCI
GFCI
100 AMPENCLOSED
CIRCUITBREAKER
H
1 2 4
G
D
B
6.2 6.8
B.3
B.7B.8
D.9
F.2
G.1
H.2
B.5
GFCI
E181
1
A
10
6
5
5
7
8
7
6
8
9
15.
13.
11. 11.
11.17.
17.
7. 7. 7. 7.
5.
5.5.
5.
1.
1.
1.
1.
1.
3.
3.
3.
3.
9.
39.
35.
41.
9.
27.
27.
27.
9.
37.9.
14.
33.
21.
21.
21.
31.
21.
21.
23.23.
2.
4.
6.
2.
8. 10.12.
8.
14.
43.
5
5
5
5
5
2
2
2
45.
12.
43.
52.
50.
48.44.
46.
41.
TP-01
33.
1
33.
1
55,57.
1
EF-CUST
35.
+96" AFF
13.4
13.+72" AFF
3
8.
3 +72" AFF
27.
GFCI
A
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:26:4
9 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SE
CT
OR
A P
OW
ER
PLA
N -
FIR
ST
FLO
OR
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E111
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1/8" = 1'-0"1 SECTOR A POWER PLAN - FIRST FLOOR
NO
RT
H
NOTES:
1. PROVIDE CONNECTION TO SECTIONAL DOORS.
2. PROVIDE CONNECTION TO HAND DRYER.
3. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING.COORDINATE EXACT LOCATION WITH A/V DRAWINGS.
4. RECEPTACLE FOR SHORT THROW PROJECTOR.
5. MOTORIZED SHADE AT SKYLIGHT. COORDINATE EXACT LOCATION WITHARCHITECT.
6. MOTORIZED PROJECTION SCREEN. COORDINATE MOUNTING HEIGHT WITHARCHITECT.
7. MOTORIZED RETRACTABLE BASKETBALL HOOP.
8. CEILING MOUNTED RECEPTACLE FOR PROJECTOR. COORDINATE EXACTLOCATION WITH A/V DRAWINGS.
9. RECEPTACLES TO SERVE AUDIO EQUIPMENT. RECEPTACLES TO BE INSTALLED INCABINETRY. COORDINATE EXACT LOCATION WITH ARCHITECT.
10. RECEPTACLES TO SERVE AUDIO EQUIPMENT. AUDIO EQUIPMENT TO BEINSTALLED IN A FREESTANDING RACK.
GENERAL NOTES:
A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FORFEEDERS AND DATA CABLING.
B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTING AND NEWUTILITIES.
C. ALL BRANCH CIRCUITING AT BUILDING EXTERIOR AND SITE SHALL BE #10AWGMINIMUM, UNLESS OTHERWISE NOTED.
D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT.
E. REFER TO LIGHTING RELAY SCHEDULE ON SHEET E703 FOR ADDITIONALINFORMATION.
F. ALL RECEPTACLES SHOWN ON THIS SHEET SHALL BE PROVIDED WITH BRANCHCIRCUITS FROM PANEL '21D1,' UNLESS OTHERWISE NOTED.
G. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISE NOTED.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
JJ
J
J
J
J
J J
J
J JJ
J J
CLASSROOM
B127
CLASSROOM
B126
COMMONS
B130
CLASSROOM
B129
CLASSROOM
B131
LIFE SKILLS
B125
RECEPTION
B100
CLASSROOM
B146
COMMONS
B145
MULTIPURPOSE
B149
CLASSROOM
B148
CLASSROOM
B150
CLASSROOM
B144
GIRLS
B142
TOILET
B112
GIRLS
B123
MDF
B120
HALLWAY
B128
TOILET
B104
BOYS
B141
PRINCIPAL
B102
CONFERENCE
B110
SECRETARY
B101
QUIET
B105
CLOSET
B109
VOLUNTEER
B117
SENSORY ROOM
B115
LACTATION RM
B111
HEALTH
B106
OFFICE
B107
CUST
B138
STAFF TOILET
B140
SMALL GROUP
B134
OFFICE
B136
BOYS
C105
SMALL GROUP
B116
MOTOR SKILLS
B114
WORKROOM
B113
HEALTH TOILET
B108
BOYS
B122
SOR
B139
STAFF ROOM
B103
HALLWAY
B119
ELEVATOR
B118
HALLWAY
B124
CHANGING TOILET
B125C
MEDIA CENTER
B132
MEDIA WORK RM
B133
STAIR
B132B
STAIR
B132A
HALLWAY
B143
HALLWAY
B147
SOR
B121
CHANGING
B125D
HALLWAY
B137
STAIR
B151
STAIR
B128A
HALLWAY
B137
STORY COVE
B135
GFCI
GFCI
GFCI
PANEL 21SBA1
PANEL MDF
PANEL 21B1
GFCI GFCI
GFCI
GFCI
GFCI
PANEL 21A1
GFCI GFCIGFCI
GFCI GFCIGFCI
/1 E115
PANEL 21A2
PANEL 41A1
12"x4" BOCT: 9' - 6"
12"x4" BOCT: 9' - 6"
/1
E111
/1 E111
GFCI GFCI
8
(2) 4 INCH AND (4) 1 INCH C. 10
7
29
GFCI
2
3
GFCI
GFCI
6
11
H
8 9 10 12 13 14 15
N
S
L
C
R
Q
M
E
F
G
D
6.8 8.2 11
B.8
F.2
J
K
P
P.7
13.6
E.7
7.8
+96" AFF
13
12
5
15
15
GFCIGFCI
14
1
GFCI
GFCI
GFCI
2
4
13
+96" AFF 12
13
+96" AFF 12
13
+96" AFF12
13
+96" AFF 12
13
+96" AFF12
13
+96" AFF 12
13 +96" AFF1213+96" AFF 12
1
17
16
7
6.6.
12.
49.
2.
6.2.
12.
10.
8.
39.
2.
18
1.1.
11.
1.
5.1.
11.
9.
7.
3.
5.
17.
23.
45.
13.
17.13.
23.
21.
19.
17.
37.
13.25. 29.
29.
35.
43.
25.
29.25.
35.
33.
31.
18.18.
24.
51.
14.
18.14.
24.
22.
20.
39.
14.
17.
13.
17.
23.
41.
17.13.
35.
17.
23.
21.
19.
13.
21
5. 1.
1.
5.
11.
43.
5.1.
11.
9.
7.
25.
2.6.
6.
12.
45.
6.2.
12.
10.
8.
2.
13
24.
22.
20.
18.
14.
27.
+96" AFF 12
47.
18.
24.
14.
18.
14.30.
34.
32.
36.
30.
26.
36.
30.
49.
26.
26.
GFCI27.
29.
29. 29.
25.
31.
31.21C1: 41.
21C1: 41.
20
19
2.
2.3.
1.
1.
4,6.
41.
37.
10.
12.
10.
14.
18.
16.
10.
8.
8.
8.
6.
6.
4.
4.
27. 27.
2.
2.
2.
25. 25. 23.
23.
27. 27.
27.
25.
21. 21.
21.21.
21.
19. 17.
19.
19.
19.
37.
3.
5.
3.
3.
5.
5.
1.
1.
1.
7.
9.
7.
9.
7.
15. 7.15.
11.
11.
13. 13.
13.
11.
21D1:14.
3.
5.
5. 5.
3.
3.
19.
21.
7.
7.9.
11.
13. 15.17.
17.17.
23 23
23
23
23
23
2323
24 24
24
3.
29.
31.
33.
40.
10.
23
34.
32.
38.
36.
20.
22,29.30.
10.
42.
26
25
26.
28.
+72" AFF
2743.
43.
28
+72" AFF51.
51.
27
28
+72" AFF
2745.
45.
28
+72" AFF27
47. 47.
28
47.
+72" AFF 49.49.
27
28
21C1: 35.
21C1: 37.
37.
39.
35.
33. +72" AFF49.
49.
27
28
+72" AFF 45.45.
27
28
+72" AFF47.
47.
27
28
+72" AFF
27
41.41.
28
+72" AFF
27
43. 43.
28
23
TP-05
21.
35.
30
23.
30 30 11.
30
30
30
30
30
30
30
12.24.
23.
36.
24.
12.
11.
23
13.
+96" AFF
FCU-MDF
EF-MDF
AH-OFCS
B
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:26:5
6 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SE
CT
OR
B P
OW
ER
PLA
N -
FIR
ST
FLO
OR
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E113
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1/8" = 1'-0"1 SECTOR B POWER PLAN - FIRST FLOOR
NO
RT
H9
NOTES:
1. REFRIGERATOR.
2. MICROWAVE.
3. WASHER/DRYER. PROVIDE A NEMA 14-30R RECEPTACLE.
4. DISHWASHER.
5. COPIER.
6. PROVIDE (3) 4 INCH AND (2) 1 INCH CONDUITS FROM CABLE TRAY TO MDF B120. CONDUITSTO BE STUBBED OUT ABOVE CABLE TRAY. REFERENCE TELECOMMUNICATIONS DRAWINGSFOR MDF LAYOUT.
7. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TO CUST B138.CONDUITS TO BE STUBBED OUT NEAR CEILING.
8. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUIT SLEEVES UP TO IDF B238 ABOVE.
9. REFERENCE SHEET E013 FOR UNDERSLAB DATA CONDUIT ROUTING.
10. CONDUITS TO BE ROUTED FROM CEILING SPACE OF CUST B138 TO IDF C101.
11. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUIT SLEEVES UP TO WORKROOM B218 ABOVE.
12. RECEPTACLE FOR SHORT THROW PROJECTOR.
13. RECEPTACLE FOR TABLET CHARGING. RECEPTACLE TO BE INSTALLED IN CABINETRY.COORDINATE EXACT LOCATION WITH ARCHITECT.
14. RECEPTACLE TO BE MOUNTED IN CASEWORK.
15. RECEPTACLE TO BE MOUNTED IN KNEE SPACE.
16. MOTORIZED PROJECTION SCREEN. COORDINATE MOUNTING HEIGHT/LOCATION WITHARCHITECT.
17. CEILING MOUNTED RECEPTACLE FOR PROJECTOR. COORDINATE EXACT LOCATION WITHA/V DRAWINGS.
18. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL '21A1', UNLESS OTHERWISE NOTED.
19. ALL RECEPTACLES DESIGNATED AS EMERGENCY IN THIS AREA SHALL BE PROVIDED WITHBRANCH CIRCUITS FROM PANEL '21SBA1', UNLESS OTHERWISE NOTED.
20. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL '21A2', UNLESS OTHERWISE NOTED.
21. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL '21B1', UNLESS OTHERWISE NOTED.
22. ALL RECEPTACLES IN THIS ROOM TO BE INSTALLED AT +48" AFF.
23. PROVIDE CONNECTION TO HAND DRYER.
24. PROVIDE CONNECTION TO ADA DOOR MOTOR AND OPERATORS. COORDINATE EXACTLOCATIONS OF DOOR OPERATORS WITH ARCHITECT.
25. ALL RECEPTACLES IN MDF B120 SHALL BE PROVIDED WITH BRANCH CIRCUITS FROMPANEL ' MDF', UNLESS OTHERWISE NOTED.
26. PROVIDE A NEMA L6-30 CENTER ABOVE THE IT RACK. COORDINATE EXACT LOCATIONWITH IT CONSULTANT.
27. RECEPTACLE TO SERVE VIDEO MONITOR.
28. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING. COORDINATEEXACT LOCATION WITH A/V DRAWINGS.
29. ROUTE HOMERUN CONDUIT UNDER SLAB TO NEAREST WALL.
30. RECEPTACLE FOR MONITOR SHALL BE MOUNTED AT 60" AFF, BELOW PROJECTORRECEPTACLE.
GENERAL NOTES:
A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITSFOR FEEDERS AND DATA CABLING.
B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALLBE KEPT CLEAR OF ALL EQUIPMENT FOREIGN TO THE ELECTRICALINSTALLATION INCLUDING PIPING, DUCTWORK, SUPPORTS, ETC.COORDINATE INSTALLATION WITH ALL OTHER TRADES.
C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUITSHALL BE COORDINATED AND REVIEWED BY ARCHITECT AND ENGINEERPRIOR TO INSTALLATION.
D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCHCIRCUIT, SHARED NEUTRALS ARE NOT PERMITTED.
E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PERHOMERUN.
F. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISENOTED.
G. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ONSHEET E702 FOR ADDITIONAL INFORMATION.
22
22
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
J
J
JJ
J JJ
J J
CLASSROOM
C113
MULTIPURPOSE
C112
CLASSROOM
C111
CLASSROOM
C109
COMMONS
C108
CLASSROOM
C107
GIRLS
C104
IDF
C101
STAFF TOILET
C103
SMALL GROUP
B134
BOYS
C105
SOR
C102
HALLWAY
C100
HALLWAY
C106
HALLWAY
C110
STAIR
C114
GFCI
GFCI
PANEL 21C1
PANEL 41C1
PANEL IDF-2
GFCI GFCIGFCI
/1
E113
GFCI
GFCI
3
(2) 4 INCH AND (4) 1 INCH C. 24
1
3 5 6
N
S
L
R
Q
M
K
P
4.3
P.7
GFCIWP
GFCIWP
0.9 6.1
5
1 +96" AFF
5
1+96" AFF
5
1+96" AFF
5
1 +96" AFF1 +96" AFF
5
1.
11.
47.
3.
1.
1.
1.5.
25.
3.
7.
9.
11.
1.
27.
6.2.
2.
4.
49.
2.
12.
4. 6. 4.
4.
12.
10.
8.
14.
24.
22.
20.
14.18.
27.
14.
26.
16.
51.
24.
14.16.14.
36.
34.
32.
28.26.
28.
53.
36.
26.
26.
30.26.
27.
27.
15.
13.
13.
23.
45.
15.
13.
17.13.
13.
25.
23.
21.
19.
29.
25.
GFCI
1.3.
5.
2.
2.
4,6.
7
5.41.9
6
66
33.
31.+72" AFF49.
49.
9
10
+72" AFF 53.53.
9
10
+72" AFF 51.51.
9
10
+72" AFF
9
47.47.
10
+72" AFF
9
45. 45.
10
87
43.
39.
29.
I42.
11
12.
24. 36.
23.12
1212 12
1211.
12"x4" BOCT: 9' - 6"
C
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:27:0
1 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SE
CT
OR
C P
OW
ER
PLA
N -
FIR
ST
FLO
OR
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E115
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1/8" = 1'-0"1 SECTOR C POWER PLAN - FIRST FLOOR
NO
RT
H
NOTES:
1. RECEPTACLE FOR SHORT THROW PROJECTOR.
2. CONDUITS TO BE ROUTED FROM CEILING SPACE OF IDF C101 TO CUST B138.
3. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUIT SLEEVES UP TO CUST C201 ABOVE.
4. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TO IDF C101.CONDUITS TO BE STUBBED OUT NEAR CEILING.
5. RECEPTACLE FOR TABLET CHARGING. RECEPTACLE TO BE INSTALLED INCABINETRY. COORDINATE EXACT LOCATION WITH ARCHITECT.
6. PROVIDE CONNECTION TO HAND DRYER.
7. ALL RECEPTACLES IN IDF C101 SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL 'IDF-2', UNLESS OTHERWISE NOTED.
8. PROVIDE A NEMA L6-30 CENTER ABOVE THE IT RACK. COORDINATE EXACTLOCATION WITH IT CONSULTANT.
9. RECEPTACLE TO SERVE VIDEO MONITOR.
10. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING.COORDINATE EXACT LOCATION WITH A/V DRAWINGS.
11. PROVIDE CONNECTION TO FSD. REFER TO MECHANICAL DRAWINGS FORADDITIONAL INFORMATION.
12. RECEPTACLE FOR MONITOR SHALL BE MOUNTED AT 60" AFF, BELOWPROJECTOR RECEPTACLE.
GENERAL NOTES:
A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FORFEEDERS AND DATA CABLING.
B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALL BEKEPT CLEAR OF ALL EQUIPMENT FOREIGN TO THE ELECTRICALINSTALLATION INCLUDING PIPING, DUCTWORK, SUPPORTS, ETC.COORDINATE INSTALLATION WITH ALL OTHER TRADES.
C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUIT SHALLBE COORDINATED AND REVIEWED BY ARCHITECT AND ENGINEER PRIORTO INSTALLATION.
D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT,SHARED NEUTRALS ARE NOT PERMITTED.
E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PERHOMERUN.
F. ALL RECEPTACLES SHOWN ON THIS SHEET SHALL BE PROVIDED WITHBRANCH CIRCUITS FROM PANEL '21C1', UNLESS OTHERWISE NOTED.
G. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISENOTED.
H. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON SHEETE702 FOR ADDITIONAL INFORMATION.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
MECHANICAL EQUIPMENTPLATFORM
A201
GYM
A111
CAFETERIA
A103
MECHANICAL EQUIPMENTPLATFORM
A200
1 2 4
B
6.2 6.8
B.3
B.7
D.9
G.1
H.2
A
3
5
2
1
4
6
A
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:27:0
5 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SE
CT
OR
A P
OW
ER
PLA
N -
SE
CO
ND
FLO
OR
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E121
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1/8" = 1'-0"1 SECTOR A POWER PLAN - SECOND FLOOR
NOTES:
1. 8 INCH BY 2 INCH BASKET CABLE TRAY. INSTALL ADJACENT TO DUCTWORK.
2. TWO (2) 2 INCH CONDUITS THROUGH DIVIDING WALL SOFFIT. COORDINATE ROUTINGWITH DUCTWORK.
3. TWO (2) 2 INCH CONDUITS DOWN TO AUDIO EQUIPMENT IN CABINETRY.
4. TWO (2) CONDUITS TO AUDIO EQUIPMENT RACK.
5. 8 INCH BY 2 INCH BASKET CABLE TRAY.
6. APPROXIMATE LOCATION OF AUDIO EQUIPMENT RACK BELOW.
GENERAL NOTES:
A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FORFEEDERS AND DATA CABLING.
B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALL BEKEPT CLEAR OF ALL EQUIPMENT FOREIGN TO THE ELECTRICALINSTALLATION INCLUDING PIPING, DUCTWORK, SUPPORTS, ETC.COORDINATE INSTALLATION WITH ALL OTHER TRADES.
C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUIT SHALLBE COORDINATED AND REVIEWED BY ARCHITECT AND ENGINEER PRIOR TOINSTALLATION.
D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT,SHARED NEUTRALS ARE NOT PERMITTED.
E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PERHOMERUN.
NO
RT
H
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
JJ
J
J
J
J
J
J
J
J
J
J
J
J
J
J
JJ
J
JJ
JJ J
MULTIPURPOSE
B226
CLASSROOM
B227
CLASSROOM
B229
CLASSROOM
B231
BOYS
B222
GIRLS
B223
SMALL GROUP
B216
COMMONS
B230
CLASSROOM
B244
CLASSROOM
B246
CLASSROOM
B248
MULTIPURPOSE
B249
CLASSROOM
B250
COMMONS
B245
BOYS
C205
BOYS
B241
GIRLS
B242
WORKROOM
B218
IDF
B238
OFFICE
B236
STAFF TOILET
B221
SOR
B220
HALLWAY
B219
HALLWAY
B217
HALLWAY
B224
HALLWAY
B228
HALLWAY
B232
HALLWAY
B235
HALLWAY
B237
HALLWAY
B247
STAFF TOILET
B240
SOR
B239
HALLWAY
C200
OFFICE
B234
STAIR
B151
STAIR
B128A
MEDIA CENTER
B132
CLASSROOM
B225
PANEL 22A1
PANEL 42A1
PANEL 42LSA1
PANEL 22B1
GFCI GFCI GFCI
GFCI GFCI
GFCI
GFCI
GFCIGFCI
GFCI
/1
E125
PANEL IDF-1
12"x4" BOCT: 9' - 6"
12"x4" BOCT: 9' - 6"
GFCIGFCI
1
GFCI
GFCI
GFCI
2
H
8 9 10 12 13 14 15
N
S
L
C
R
Q
M
E
F
G
D
6.8 8.2 11
F.2
J
K
P
P.7
13.6
E.7
7.8
11.9
4
+96" AFF3
4
+96" AFF 3
+96" AFF
4
3
4
+96" AFF 3
4
+96" AFF3
4
+96" AFF 3
4+96" AFF3
4
4
+96" AFF 3
4
38.
38.
38.
38.
31. 31.
27.
25.
29.
29.
29.
2.2. 4,6.
5.3.1.
15. 13.13.
45.
23.
15.
13.
17.13.
35.
17.
23.
21.
19.
3.1.1.
47.
11.
3.
1.
5.1.
25.
5.
11.
9.
7.
7
6.4.
4.
13.2.
49.
6.2.
2.
12.
10.
8.
4.
2.18.
24.
22.
20.
16. 14.
14.
14.18.
27.
+96" AFF 3
14.
51.
24.
16.
28. 26.
30.
34.
32.
36.
26.
26.30.
+96" AFF 3
26.
36.
53.
28.
6
5
4.2.2.
12.47.
4.
2.
6.2.6.
12.
10.
8.
39.
16. 14.14.
24.
49.
16.
14.
18.14.
18.
24.
22.
20.
39.
28.48.
28.28.
39.
26.
26. 26.
30.30.
37.
27. 25.25.
35.
41.
27.
25.
29.25.
29.
35.
33.
31.
13.
23.
43.
15.
13.
17.13.
17.
23.
21.
19.
15. 13.
37.
5.3. 3.
1.
45.
5.
1.
5.1.
11.
9.
7.
1.
3.
7
GFCI
26.
88
88
8
8
888
49.49.
+72" AFF
1112
11
12
47.+72" AFF 47.
51.51.+72" AFF
11
12
53.53.+72" AFF
11
12
11
12
45.+72" AFF45.
47.47.
+72" AFF
1112
49.49.+72" AFF
11
12
11
12
45.+72" AFF 45.
11
12
41.+72" AFF41.
11
12
43.+72" AFF43.
41.
43.
109
33.
35.
39.
37.
44.
46.
36.
38. 40.
42.
22C1:35.
22C1:37.
COPIER
TP-10
TP-06
FCU-B-IDF
13 11.
13 13.
1324.
13
23.13
1324.
1335. 1323. 45.13
13 12.
EF-TLT
B
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:27:1
1 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SE
CT
OR
B P
OW
ER
PLA
N -
SE
CO
ND
FLO
OR
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E123
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1/8" = 1'-0"1 SECTOR B POWER PLAN - SECOND FLOOR
NO
RT
H
NOTES:
1. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TOWORKROOM B218. CONDUITS TO BE STUBBED OUT ABOVE ACCESSIBLE CEILING.
2. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TO IDF B238.CONDUITS TO BE STUBBED OUT NEAR CEILING.
3. RECEPTACLE FOR SHORT THROW PROJECTOR.
4. RECEPTACLE FOR TABLET CHARGING. RECEPTACLE TO BE INSTALLED INCABINETRY. COORDINATE EXACT LOCATION WITH ARCHITECT.
5. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCHCIRCUITS FROM PANEL '22A1', UNLESS OTHERWISE NOTED.
6. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCHCIRCUITS FROM PANEL '22B1', UNLESS OTHERWISE NOTED.
7. (3) 4 INCH AND (2) 2 INCH SLEEVES FROM MDF BELOW.
8. PROVIDE CONNECTION TO HAND DRYER.
9. ALL RECEPTACLES IN IDF B238 SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL 'IDF-1', UNLESS OTHERWISE NOTED.
10. PROVIDE A NEMA L6-30 CENTER ABOVE THE IT RACK. COORDINATE EXACTLOCATION WITH IT CONSULTANT.
11. RECEPTACLE TO SERVE VIDEO MONITOR.
12. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING.COORDINATE EXACT LOCATION WITH A/V DRAWINGS.
13. RECEPTACLE FOR MONITOR SHALL BE MOUNTED AT 60" AFF, BELOWPROJECTOR RECEPTACLE.
GENERAL NOTES:
A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FORFEEDERS AND DATA CABLING.
B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALL BE KEPTCLEAR OF ALL EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATIONINCLUDING PIPING, DUCTWORK, SUPPORTS, ETC. COORDINATE INSTALLATIONWITH ALL OTHER TRADES.
C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUIT SHALL BECOORDINATED AND REVIEWED BY ARCHITECT AND ENGINEER PRIOR TOINSTALLATION.
D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT,SHARED NEUTRALS ARE NOT PERMITTED.
E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PERHOMERUN.
F. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISE NOTED.
G. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON SHEET E702FOR ADDITIONAL INFORMATION.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
J
JJ
J
J
JJ J
JJ
CUST
C201
CLASSROOM
C209
CLASSROOM
C207
CLASSROOM
C213
MULTIPURPOSE
C212
CLASSROOM
C211
COMMONS
C208
BOYS
C205
GIRLS
C204
HALLWAY
C200
HALLWAY
C206
HALLWAY
C210
STAFF TOILET
C203
SOR
C202
HALLWAY
C200
STAIR
C114
PANEL 42C1
PANEL 42LSC1
PANEL 22C1
GFCI
GFCI GFCI
GFCI
GFCI
GFCI
/1
E123
GFCI
GFCIGFCI
1
1
3 5 6
N
S
L
R
Q
M
K
P
4.3
P.7
0.9 6.1
3
2 +96" AFF
3
2+96" AFF
3
2+96" AFF
3
2 +96" AFF
1.
11.
45.
3.
1.
1.5.
25.
3.
7.
9.
11.
5.1.
15.
13.
13.
23.
43.
15.
13.
17.17.
13.
25.
23.
21.
19.
27.
29.
25.
29.
29.
6. 47.2.
4.
47.
2.
12.
4. 6. 4.
4.
12.
10.
8.
3
18.
24.
22.
20.
14.18.
27.
14.
16.
49.
24.
14.16.14.
2 +96" AFF
30.
36.
34.
32.
28.26.
28.
51.
36.
26.
26.
30.26.
7
4
5.41.9
5 5
5
26.
51.51.
+72" AFF
67
47. +72" AFF
6
7
49.49.
+72" AFF
67
6
7
43.+72" AFF 43.
6
7
45.+72" AFF45.
41.
39.
31.
33.
TP-09
88
8 8 8
23.11.
12.
24. 36.
12"x4" BOCT: 9' - 6"
C
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:27:1
6 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SE
CT
OR
C P
OW
ER
PLA
N -
SE
CO
ND
FLO
OR
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E125
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1/8" = 1'-0"1 SECTOR C POWER PLAN - SECOND FLOOR
NO
RT
H
NOTES:
1. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TO CUST C201.CONDUITS TO BE STUBBED OUT NEAR CEILING.
2. RECEPTACLE FOR SHORT THROW PROJECTOR.
3. RECEPTACLE FOR TABLET CHARGING. RECEPTACLE TO BE INSTALLED INCABINETRY. COORDINATE EXACT LOCATION WITH ARCHITECT.
4. PROVIDE CONNECTION TO FIRE/SMOKE DAMPER.
5. PROVIDE CONNECTION TO HAND DRYER.
6. RECEPTACLE TO SERVE VIDEO MONITOR.
7. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING.COORDINATE EXACT LOCATION WITH A/V DRAWINGS.
8. RECEPTACLE FOR MONITOR SHALL BE MOUNTED AT 60" AFF, BELOW PROJECTORRECEPTACLE.
GENERAL NOTES:
A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FOR FEEDERSAND DATA CABLING.
B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALL BE KEPT CLEAROF ALL EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION INCLUDING PIPING,DUCTWORK, SUPPORTS, ETC. COORDINATE INSTALLATION WITH ALL OTHER TRADES.
C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUIT SHALL BECOORDINATED AND REVIEWED BY ARCHITECT AND ENGINEER PRIOR TO INSTALLATION.
D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT, SHAREDNEUTRALS ARE NOT PERMITTED.
E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PER HOMERUN.
F. ALL RECEPTACLES SHOWN ON THIS SHEET SHALL BE PROVIDED WITH BRANCHCIRCUITS FROM PANEL '22C1', UNLESS OTHERWISE NOTED.
G. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISE NOTED.
H. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON SHEET E702 FORADDITIONAL INFORMATION.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
CAFETERIA
A103
A BEXIT
ENTRY
EXIT
TRAYRETURN
ENTRY
CAFETERIA
A103
A BEXIT
ENTRY
EXIT
TRAYRETURN
ENTRYF
F
F
F
F
F
FF
FF
F
F
P
F
F
F
F F
F
F F
F
F
F
FS TS
F
VESTIBULE
A100
BOILER
A119
BLDG STORAGE
A117
COMMUNITY ROOM
A102
PE OFC/STG
A114
CUSTODIAL
A116
ELEC
A118
BOYS
A109
GIRLS
A110
FAMILY TOILET
A107
TBL STORAGE
A105
GYM
A111
MUSIC ROOM / STAGE
A113
LOBBY
A101
LOST AND FOUND
A115
CUST
A104C
CAFETERIA
A103
KITCHEN
A104
PE CIRCULATION
A106
CUST
A112
KITCHEN
A104D
RAMP
A121
HALL
A106B
WF
A120
KDU
FACP
/1
E133
/1 E135
H
1 2 4
G
D
B
6.2 6.8
B.3
B.7B.8
D.9
F.2
G.1
H.2
B.5
A
121LSD1: 4.
A
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:27:1
9 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SE
CT
OR
A F
IRE
ALA
RM
PLA
N -
FIR
ST
FLO
OR
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E131
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1/8" = 1'-0"1 SECTOR A FIRE ALARM PLAN - FIRST FLOOR
NO
RT
H
NOTES:
1. COORDINATE QUANTITY AND LOCATION OF FIRE SPRINKLER FLOW AND TAMPERSWITCHES WITH FIRE SPRINKLER CONTRACTOR.
GENERAL NOTES:
A. THE FIRE ALARM SYSTEM IS A CONTRACTOR DESIGN-BUILD SYSTEM. DEVICELOCATIONS AND QUANTITIES SHOWN ARE PREFERRED; HOWEVER, ADDITIONALDEVICES MAY BE REQUIRED TO COMPLY WITH CODE. CONTRACTOR SHALLPROVIDE ADDITIONAL FIRE ALARM DEVICES, ACCESSORIES AND ANY ADDITIONALITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL CODE COMPLIANTSYSTEM. REFERENCE SPECIFICATION DIVISION 28 30 00 FOR ADDITIONALINFORMATION.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
F
F
F F
F
FF
F
F FF
F
F
F
F
F
F
F
F
F
F
F
FF
F
F
F
F
F
F
F
F
F
P
F F
F
F F
F F F
P
P
F
P
P
F
F
F
F
F
CLASSROOM
B127
CLASSROOM
B126
COMMONS
B130
CLASSROOM
B129
CLASSROOM
B131
LIFE SKILLS
B125
RECEPTION
B100
CLASSROOM
B146
COMMONS
B145
MULTIPURPOSE
B149
CLASSROOM
B148
CLASSROOM
B150
CLASSROOM
B144
GIRLS
B142
TOILET
B112
GIRLS
B123
MDF
B120
HALLWAY
B128
TOILET
B104
BOYS
B141
PRINCIPAL
B102
CONFERENCE
B110
SECRETARY
B101
QUIET
B105
CLOSET
B109
VOLUNTEER
B117
SENSORY ROOM
B115
LACTATION RM
B111
HEALTH
B106
OFFICE
B107
CUST
B138
STAFF TOILET
B140
SMALL GROUP
B134
OFFICE
B136
BOYS
C105
SMALL GROUP
B116
MOTOR SKILLS
B114
WORKROOM
B113
HEALTH TOILET
B108
BOYS
B122
SOR
B139
STAFF ROOM
B103
HALLWAY
B119
ELEVATOR
B118
HALLWAY
B124
CHANGING TOILET
B125C
MEDIA CENTER
B132
MEDIA WORK RM
B133
STAIR
B132B
STAIR
B132A
HALLWAY
B143
HALLWAY
B147
SOR
B121
CHANGING
B125D
HALLWAY
B137
STAIR
B151
STAIR
B128A
HALLWAY
B137
STORY COVE
B135
3
E501
KDU
/1
E135
/1 E135
/1
E131
/1 E131
H
8 9 10 12 13 14 15
N
S
L
C
R
Q
M
E
F
G
D
6.8 8.2 11
B.8
F.2
J
K
P
P.7
13.6
E.7
7.8
11.9
c c c
cc
c c
c c c
B
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:27:2
4 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SE
CT
OR
B F
IRE
ALA
RM
PLA
N -
FIR
ST
FLO
OR
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E133
AM
T
SJT
700 H
OW
AR
D A
VE
, E
UG
EN
E, O
RE
GO
N 9
7404
1/8" = 1'-0"1 SECTOR B FIRE ALARM PLAN - FIRST FLOOR
NO
RT
H
GENERAL NOTES:
A. THE FIRE ALARM SYSTEM IS A CONTRACTOR DESIGN-BUILD SYSTEM. DEVICELOCATIONS AND QUANTITIES SHOWN ARE PREFERRED; HOWEVER, ADDITIONALDEVICES MAY BE REQUIRED TO COMPLY WITH CODE. CONTRACTOR SHALLPROVIDE ADDITIONAL FIRE ALARM DEVICES, ACCESSORIES AND ANY ADDITIONALITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL CODE COMPLIANTSYSTEM. REFERENCE SPECIFICATION DIVISION 28 30 00 FOR ADDITIONALINFORMATION.
-
12-31-14EXPIRES
REGIS
TERED P
ANISSE
FOR
LOIG
N
E
N EE
R
Ju ly9991,3
44775
OREGON
1
GRA
NT
R. ARTHE
MER
P
F
F
F
F
F
F
F
F
F
F
F
FF
P P
CLASSROOM
C113
MULTIPURPOSE
C112
CLASSROOM
C111
CLASSROOM
C109
COMMONS
C108
CLASSROOM
C107
GIRLS
C104
IDF
C101
STAFF TOILET
C103
BOYS
C105
SOR
C102
HALLWAY
C100
HALLWAY
C106
HALLWAY
C110
STAIR
C114
/1
E133
1
3 5 6
N
S
L
R
Q
M
K
P
4.3
P.7
0.9 6.15.41.9
c c
ccc
C
RE
VIS
ION
S:
CH
EC
KE
D:
PR
OJE
CT
#:
ISS
UE
DA
TE
:
DR
AW
N:
PR
INT
ED
O
N:
2014 P
IVO
T A
RC
HIT
EC
TU
RE
FR
OM
FIL
E:
C
9/1
2/2
014 3
:27:2
7 P
MC
:\R
evit L
ocal F
iles\1
3-1
532_H
ES
ME
P14\1
3-1
532_H
ES
ME
P14_sta
cy.h
ansen.r
vt
SE
CT
OR
C F
IRE
ALA
RM
PLA
N -
FIR
ST
FLO
OR
EU
GE
NE
SC
HO
OL D
IST
RIC
T
BU
ILD
ING
AN
D S
ITE
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
HO
WA
RD
ELE
ME
NT
AR
Y S
CH
OO
L
13
36
09
/23
/20
14
E135
AM
T
SJT
70
top related