90%%d corner rebar, - home plans, floor plans, house designs | design … · 2017-08-30 · design...

Post on 22-Jun-2018

217 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

1

SHEET

of

ALLPLANS

11

11

2 J

oh

n G

alt

Blv

d.

Om

ah

a,

NE

68

13

7

To

ll f

ree:

(80

0)

94

7-7

52

6

Fax:

(402)

331-5

507

REVERSEAVAILABLE

customizable

ww

w.d

esig

nb

asics.c

om

TH

E P

UR

CH

ASE

R O

F T

HE

SE P

LA

NS

IS G

IVEN

A L

IMIT

ED L

ICEN

SE

TO

RE

PRO

DU

CE

TH

ESE

PL

AN

S

FOR

CO

NST

RU

CT

ION

PU

RPO

SES

ON

LY

AN

D F

UR

TH

ER

DIS

TR

IBU

TIO

N

IS S

TR

ICT

LY

PR

OH

IBIT

ED

....W

HE

RE

G

RE

AT

D

ES

IG

N M

AT

TE

RS

DE

SIG

N B

ASI

CS,

LL

C. I

S A

PR

OFE

SSIO

NA

L R

ESI

DE

NT

IAL

DE

SIG

N F

IRM

LO

CA

TE

D IN

OM

AH

A, N

E. B

EC

AU

SE S

ITE

CO

ND

ITIO

NS

MA

Y V

AR

Y D

ESI

GN

BA

SIC

S, L

LC

. CA

NN

OT

WA

RR

AN

T T

HE

SU

ITA

BIL

ITY

OF

TH

ESE

PL

AN

S FO

R U

SE

ON

YO

UR

SPE

CIF

IC S

ITE

. C

ON

STR

UC

TIO

N F

RO

M T

HE

SE

PLA

NS

SHO

UL

D N

OT

BE

UN

DE

RT

AK

EN

WIT

HO

UT

TH

E

ASS

IST

AN

CE

OF

A C

ON

STR

UC

TIO

N P

RO

FESS

ION

AL

.

TOP VIEW

4" [101.60mm]

758

" [193.68mm]

1’-034

" [323.85mm]

758

" [193.68mm]

8" [203.20mm]

4" [101.60mm]

3’-8" [1117.60mm]

6" [

152.4

0m

m]

1’-038

" [314.33mm]

1114

" [285.75mm]

1’-838

" [517.53mm]

4" [

101.6

0m

m]

111 4

" [

28

5.7

5m

m]

1’-

03 8" [

31

4.3

3m

m]

75 8

" [

19

3.6

8m

m]

NOTE:

SEE PRODUCT DETAILS FOR REBAR PLACEMENT DIMENSIONS.

OFF-CENTERCENTER

INTERIOREXTERIOR

CLEAR COVER DIMENSION WILL DEPEND ON SIZE OF HORIZONTAL AND VERTICAL REBAR.

6" [152mm]

258

" [67mm]258

" [67mm]

1114

" [286mm]

1" [25 mm] MIN

2" [51 mm] MAX

6" [152mm]

258

" [67mm]258

" [67mm]

1114

" [286mm]

3" [76mm]3" [76mm]

FOX "A" "B"

14" [356mm]8" [152mm]4"

16" [406mm]8" [203mm]6"

18" [457mm]10" [254 mm]8"

FOX CORNER BAR SPACING

10" 12" [305mm] 16" [508mm]

90%%d CORNER REBAR,

LAP REBAR 40 BARDIAMETERS, MINIMUM

VERTICAL BARS,

AS REQUIRED

AS REQUIRED

HORIZONTAL BARS,

"A"

"B"

"A"

"B"

12" 14" [356mm] 22" [559mm]

90%%d FOX BLOCK

FOX BLOCK FORMS

PROVIDE DOWELS BETWEEN POURS

AS SPECIFIED

VERTICAL REBAR AS SPECIFIED

VERTICAL CONSTRUCTION JOINT

HORIZONTAL REBAR AS SPECIFIED

ELEVATION VIEW

REINFORCING AS SPECIFIED.

CONTINUOUS FOOTING - SIZE AND

SLOPED FINISHED GRADE

DRAIN TILE

THERMAL BARRIER

15-MINUTE

GRANULAR FILL

REBAR DESIGN AND PLACEMENT

CONCRETE FLOOR

UNDISTURBED SOIL

AGGREGATE

AS SPECIFIED

STRAIGHT VERTICAL DOWELOR HOOK AS SPECIFIED.

PARGING

DAMP PROOFING OR

WATERPROOF MEMBRANE

AS PER CODE

PARGING

SILL PLATE

ANCHOR AS

REQUIRED BY CODE

REINFORCING AS SPECIFIED.

CONTINUOUS FOOTING - SIZE AND

THERMAL BARRIER

15-MINUTE

FOX BLOCK FORMS

HORIZONTAL REBAR AS SPECIFIED

VERTICAL REBAR AS SPECIFIED

DOWELS AS SPECIFIED

(IF REQUIRED)

HEIGHT AS

SPECIFIED

UNDISTURBED SOIL

OR BEDROCK

DRAIN TILE

AGGREGATE

FILTER CLOTH,

IF NEEDED

EPS INSULATION

(IF REQUIRED)

BASE AS SPECIFIED

EXTERIOR FINISH

ROOF SYSTEM

FOX BLOCK

SLOPED FINISHED GRADE

INSULATION

FIRST FLOOR

BASEMENT

PARGING

EXTERIOR FINISH

CONCRETE FLOOR

GRANULAR FILL

VAPOR RETARDER

FLOOR FRAMING

RIM JOIST WITH ANCHOR BOLTS

ROOF DETAIL

THERMAL BARRIER

15-MINUTE

THERMAL BARRIER

15-MINUTE

DRAIN TILE

AGGREGATE

DAMP PROOFING OR

WATERPROOF MEMBRANE

AS PER CODE

C

1

2014

FO

X B

LO

CK

SS

EC

TIO

NS

SECOND FLOOR

FIRST FLOOR

BASEMENT

THERMAL BARRIER

15-MINUTE

THERMAL BARRIER

15-MINUTE

ROOF SYSTEM

INSULATIONROOF DETAIL

RIM JOIST WITH ANCHOR BOLTS

CONCRETE FLOOR

GRANULAR FILL

VAPOR RETARDER

SLOPED FINISHED GRADE

PARGING

DRAIN TILE

AGGREGATE

FOX BLOCK

EXTERIOR FINISHFLOOR FRAMING

DAMP PROOFING OR

WATERPROOF MEMBRANE

AS PER CODE

FLOOR JOIST

EXTERIOR FINISH

JOIST HANGER

RIM JOIST

ANCHOR BOLTS PER TABLE

FLOOR DECKING

FOX BLOCK

WALL OUT-OF-PLANE ANCHOR

IN SEISMIC DESIGN, BY ENGINEER

OF RECORD

DOUBLE OR STAGGERED

ANCHOR BOLT AS REQUIRED

BY ENGINEER OF RECORD

LAP SPLICE AS REQUIRED

HORIZONTAL REBAR AS REQUIRED

BY ENGINEER OF RECORD

VERTICAL REBAR AS REQUIRED

BY ENGINEER OF RECORD

FLOOR JOIST

15 MINUTE THERMAL BARRIER

(i.e. 1/2" GYPSUM BOARD)

JOIST HANGER

RIM JOIST

ANCHOR BOLTS PER TABLE

FLOOR DECKING

FOX BLOCK

DECK JOIST

WOOD DECK

LEDGER BOARD

HORIZONTAL REBAR AS

REQUIRED BY CODE

VERTICAL REBAR AS

REQUIRED BY CODE

EXTERIOR FINISH

RIM JOIST

SIMPSON ICFLC-W

SIMPSON ICFVL AS REQUIRED

BY ENGINEER OF RECORD

STEEL LEDGER

CONNECT WITH SCREWS

CONNECT WITH SIMPSON SCREWS

SIMPSON ICFVL AS REQUIRED

BY ENGINEER OF RECORDNOTE: SIMSPON STRONG TIE

ICF LEDGER CONNECTION

NOT FOR EXTERIOR USE.

ANCHOR BOLTS

1. ESTABLISH TOP OF JOIST ELEVATION AND MARK THE

FORM WITH A CHALK LINE.

2. ESTABLISH BOTTOM OF JOIST ELEVATION AND MARK THE

FORM WITH A CHALK LINE.

3. 6.5 INCH WIDE BEVELED CUT-OUTS ARE TO BE PROVIDED

IN THE FORM WALL. THE HEIGHT OF THE CUT-OUTS ARE

DETERMINED AS SHOWN IN THE DRAWING ABOVE. (ONE

INCH BELOW THE TOP CHALK LINE AND ONE INCH ABOVE

THE BOTTOM CHALK LINE.

4. SCREW THE RIM JOIST TO THE FORM WEB STRIPS AT THE

PROPER ELEVATION, LABELED "FOX BLOCKS".

5. LAYOUT AND INSTALL THE RIM JOIST ANCHOR BOLTS AS

REQUIRED.

6. FILL THE FORMS WITH CONCRETE AND ALLOW THE

CONCRETE TO CURE BEFORE INSTALLING JOIST HANGERS

OR LOADING THE RIM JOIST.

ANCHOR BOLTS PER TABLE

RIM JOIST

RIM JOIST

SCREWS

VERTICAL REBAR AS

REQUIRED BY CODE

HORIZONTAL REBAR AS

REQUIRED BY CODE

AS REQUIRED

15 MINUTE THERMAL BARRIER

1/2" GYPSUM BOARD

INSULATION

ROOFING

ROOF TRUSS

EXTERIOR FINISH

6 MIL. POLY VAPOUR BARRIER

2x6 PLATE ON SILL GASKET ACHORED

TO CONCRETE AS REQUIRED BY

ENGINEER OF RECORD.

VERTICAL REBAR AS REQUIRED

BY ENGINEER OF RECORD

HORIZONTAL REBAR AS REQUIRED

BY ENGINEER OF RECORD

CLIP ANGLE AT EACH ROOF

FRAMING MEMBER IN SEISMIC

DESIGN, BY ENGINEER OF RECORD

FLOOR JOIST

THERMAL BARRIER

15-MINUTE

FLASHING & WEEP HOLES

xLERATOR AS SPECIFIED

FOX BLOCK FORMS

ACRYLIC PARGING

(OVERLAPS DAMP

PROOFING MEMBRANE)

FOX CORBEL BLOCK FORM

ANCHOR BOLTS PER

CODE REQUIREMENTS

VERTICAL REBAR AS SPECIFIED

HORIZONTAL REBAR AS REQUIRED

THERMAL BARRIER

15-MINUTE

EXTERIOR FINISH

HORIZONTAL BARS

AS REQUIRED

WOOD JOIST

15-MINUTE

THERMAL BARRIER

SUBFLOOR

2 X 4 SILL PLATE ON SILL

SEAL WITH ANCHOR

BOLTS AS REQUIRED

VERTICAL BARS

AS REQUIRED

FOX BLOCK xLerator

REINFORCEMENT

FIRST POUR

SECOND POUR

EXTERIOR FINISH

HORIZONTAL BARS

AS REQUIRED

WOOD JOIST

15-MINUTE

THERMAL BARRIER

SUBFLOOR

2 X 4 SILL PLATE ON SILL

SEAL WITH ANCHOR

BOLTS AS REQUIRED

VERTICAL BARS

AS REQUIRED

FOX xLerator REINFORCEMENT

FIRST POUR

SECOND POUR

TOP CHORD BEARING

FOX BLOCK FORMS

VERTICAL REBAR AS SPECIFIED

HORIZONTAL REBAR AS SPECIFIED

PARTITION WALL

MASONARY SCREW OR ALTERNATE

AS SPECIFIED

REMOVE PORTION OF FORM TO

FACE OF CONCRETE AFTER

CONCRETE POUR

PLYWOOD BACKING TO CONCRETE

INSTALL WOOD BLOCKING OR

WITH CONCRETE FASTNERS

top related