8-BAY RAID STATION
Manual
8-bay raid station 2
Content
1. Features 3 1.1 Overview 3 1.2 SATA features 3 1.3 USB features 32. Specifications 43. System requirements 44. The device at a glance 4 4.1 Overview 4 4.2 The LED indications 55. Package contents 66. Getting started 6 6.1 HDD installation 6 6.2 Power on/off 8 6.3 eSATA slot bracket installation 87. Configuration 9 7.1 Preparation 9 7.2 Changing the host connection 9 7.3 Disconnecting an USB device 10 7.4 HDD HotPlug 108. Setting the RAID mode 10 8.1 CLEAN mode 11 8.2 Other RAID modes 139. Rebuilding a redundant drive 1510. Troubleshooting 1711. Appendix 18 11.1. CLEAN mode 18 11.2 LARGE mode 19 11.3 R00 mode 20 11.4 R30 mode 22 11.5 R50 mode 24
Dear customer!
Congratulations for purchasing one premium quality SHARKOON product.For a long life time and to take full advantage of this product we recommend that you read this manual completely.
Have a good time with our product!SHARKOON Technologies
8-bay raid station 3
1. Features
1.1 Overview
• ExternalRAIDcasewitheightmountingbaysfor2.5"and3.5"SATAHDDs • Supportedmodes:Clean/Single,LargeandRAID00/30/50 • EasyRAIDmodeconfiguration • AutomaticrebuildfunctioninRAID30/50modes • Internalinterfaces:SATAIandII(compatiblewithSATAIII) • Externalinterfaces:eSATAandUSB3.0 • FastSwapmechanismforeasyHDDhandling • Premiumqualitycraftsmanship • On/offbutton • LEDindicationsforpower,HDDactivityandrebuildmode • Pre-installedfan
1.2 SATA features
• PortMultiplierFunctionality • Auto-negotiationbetweenSATAI(1.5Gbps)andSATAII(3Gbps) • HotPlugsupportinCLEANmode • SupportsNativeCommandQueue(NCQ) • SupportsPortMultiplierAwareandnon-PortMultiplierAwareHostinRAIDmode • SupportsAsynchronousSignalRecovery • SupportsSpreadSpectrumClocking • SupportsBISTandLoopbackMode • Supports48-bitLBAaddressing • SupportsAsynchronousNotification
1.3 USB features
• CompatiblewithUSBSuperSpeed,HighSpeedandFullSpeed • CompatiblewithOHCI/UHCI/EHCIhosts • SupportsMassStorageClass
8-bay raid station 4
2. Specifications
• Eightmountingbaysfor2.5"and3.5"SATAHDDs • Metalchassis(SECC)andplasticfrontpanel(ABS) • Dimensions:340x150x340mm(LxWxH) • Weight:6.5kg • 300Wfullrangepowersupply
3. System requirements
• IntelPentium-III500MHzequivalentorfaster • WindowsXP,WindowsVista,Windows7withthelatestServicePacks • 64MBofRAM(minimum) • SuperVGA(800x600)orhigherresolutiondisplaywithatleast256colors • Mouseorcompatiblepointingdevice • SATAconnection:IntelICHoroptionalHostBusAdaptercardandassociatedsoftware driverswithPortMultipliersupport • USBconnection:USB2.0or3.0directhostconnection
4. The device at a glance
4.1 Overview
8-bay raid station 5
4.2 The LED indications
1. POWER LED
DESCRIPTION ORANGELED
PowerOn On
PowerOff Off
2. SYS LEDs
DESCRIPTION GREENLED
SYS1orSYS2notready/NoPower Off
SYS1orSYS2ready(Idle) On
SYS1orSYS2ready(Active) On
3. HDD LEDs
DESCRIPTION GREENLED REDLED
HDDUnplugged/NoPower Off Off
HDDplugged(Idle) On Off
HDDplugged(Active) Blink(On) Off
ErrorState(OneorMoreBadPartialVolumes) Off On
HDDRebuild(APhysicalPartitionisbeingRebuild;i.e.MirroringMode)
Off Blink(On)
8-bay raid station 6
5. Package contents
• 8-BAYRAIDSTATION • 8xHDDmountingbays • 1xUSB3.0cable • 1xeSATAcable • 1xpowercord • 32xmountingscrewsfor2.5"HDDs/SSDs • 32xmountingscrewsfor3.5"HDDs • 1xSATAtoeSATAcablewithbracket
6. Getting started
6.1 HDD installation
1.Openthefrontdoor,thenunlocktheHDDmountingframelockandremovetheHDD mountingframefromthe8-BAYRAIDSTATION(fig.1).
Fig.1
2.PlacetheHDDintotheHDDmountingframe(fig.2).
Fig.2
8-bay raid station 7
3.UsethemountingscrewstosecurelyattachtheHDDtothemountingframe(fig.3).
Fig.3
4.SlidetheHDDmountingframebackintothe8-BAYRAIDSTATION(fig.4).
Fig.4
5.ClosethefrontdoortocompletetheHDDinstallation(fig.5).
Fig.5
8-bay raid station 8
6.2 Power on/off
Pressthepowerbuttontoswitchonthedevice.Pressagaintopoweritoff.
6.3 eSATA slot bracket installation
1.RemovetheanchorscrewoftheslotbezelandtakeitfromtherearsideofyourPC case(fig.6).
Fig.6
8-bay raid station 9
2.InserttheincludedeSATAbracketintotheslotbracketandattachittothecaseusing theanchorscrew(fig.7).
Fig.7
3.ConnecttheSATAcableoftheeSATAbrackettoafreeSATAportofyour PCmainboard.
7. Configuration
7.1 Preparation
1.SATAhostconnection Thisinstallationguideassumesthatyouhavealreadyconnectedthe8-BAYRAID STATIONtoaSATAoreSATAhostcontrollerwithPortMultiplier(PM)support.
Note: If you use a host controller that does not provide Port Multiplier support (Such as Intel ICH), the CLEAN mode is not available when configuring the 8-BAY RAID STATION. Only one disk is available on the host computer.
2.USBhostconnection Ifyouareconnectingyour8-BAYRAIDSTATIONusinganUSBconnectiontoyourhost, theUSBportshouldbecompliantwithUSB2.0or3.0.
7.2 Changing the host connection
The8-BAYRAIDSTATIONsupportsbothUSBandeSATAhostconnections,althoughonly oneconnectioncanbeattachedatthesametime. IfitbecomesnecessarytoswitchthehostconnectionbetweeneSATAandUSB,thehost computersystemandthe8-BAYRAIDSTATIONshouldbothbepowereddownpriorto changingthehostconnection,inordertoavoiddataloss.Afterchangingthehost connection,bothdevicescanbepowered-onagaintocontinueoperationwiththenew host connection.
8-bay raid station 10
7.3 Disconnecting an USB device
USB3.0externaldevicesprovidesupportforPlug&Playconnection,sothatyourUSB storagedevicecanbeconnectedanddisconnectedwhilethecomputerisrunning. Topreventdatalossorotherfailures,werecommendthefollowingprocedurewhen disconnectingyourUSB3.0storagedevicefromyourhostcomputersystem:
BeforeyoushutdownyourPCremovethe8-BAYRAIDSTATIONfromyoursystem’s hardwareconfigurationbydouble-clickingthesymbolinthetaskbar.Amenuwill openup.Selectthe8-BAYRAIDSTATIONtosecurelyremoveit.Switchoffthedeviceand shutdownyourPC.
7.4 HDD HotPlug
Theharddiskdrivesshouldnotbehot-plugged,butcanbeunpluggedwhilethe systemisrunning.However,toavoiddatacorruptionorloss,makesurethatthehost systemisnotcurrentlyusinganydrivethatisabouttobeunplugged.
8. Setting the RAID mode
Todefineastoragemodeforthefirsttime,makesurethattheharddiskdrivesare mounted,thenturnoffthepowerbeforesettingtheRAIDmodeswitchesontherear sideofthe8-BAYRAIDSTATIONtothedesiredmode. Tochangethestoragemodeafterwards,settheRAIDmodeswitchestothedesired position.Pressandholdthesetupbutton,thenswitchonthedevicetocreatethenew virtualvolume(s).
Notes: Creating new virtual volumes will destroy any existing data saved on the volumes! Back up your data before reconfiguring the storage mode!
8-bay raid station 11
8.1 CLEAN mode
1.Switchoffthedevice(fig.8).
Fig.8
2.ToggletheRAIDmodeswitchtotheCleanmodeaccordingtothefollowingchart(fig.9):
Fig.9
8-bay raid station 12
3.Removetheleftsidepanelfromthecasebylooseningthethumbscrewsontherear side(fig.10aandb).
Fig.10a Fig.10b
4.ToggletheCleanmodejumperinsidethedevicetothe“On”position(fig.11).
Fig.11
Warning: Except for the Clean mode the Clean mode jumper must be toggled to the “Off” position!
8-bay raid station 13
5.SwitchonthedevicetocompletetheRAIDmodesetting(fig.12).
Fig.12
8.2 Other RAID modes
1.Switchoffthedevice(fig.13).
Fig.13
8-bay raid station 14
2.ToggletheRAIDmodeswitchestothedesiredRAIDmodeaccordingtothefollowing chart(fig.14):
Fig.14
3.Pressandholdthesetupbutton(fig.15).
Fig.15
8-bay raid station 15
5.SwitchonthedeviceandthenreleasethesetupbuttontocompletetheRAIDmode configuration(fig.16).
Fig.16
9. Rebuilding a redundant drive
The8-BAYRAIDSTATIONduplicatesalldatatoseparatedrivesinordertoprotectagainst datalossduetodrivefailureinR30andR50mode.Thefollowingexampleillustrates theprocedureofrebuildingaredundantdrive.
1.Ifdrive2fails,pleaseremoveitfromthedevice(fig.17).
Fig.17
8-bay raid station 16
2.Switchoffthedevice(fig.18).
Fig.18
3.ReplacethedefectiveHDDwithaharddiskdriveofthesamecapacityorbigger (fig.19).
Fig.19
8-bay raid station 17
4.Switchonthedevice(fig.20).
Fig.20
5.The8-BAYRAIDSTATIONwillstartrebuildingthevirtualvolumeautomatically (rebuildspeed:approximately200GB/hour).
10. Troubleshooting
1. Device is not recognized Makesureallcableshavebeenproperlyconnected. FortheUSB3.0controllerthelatestdriversandthenewestfirmwaremustbeinstalled.
2. Cannot operate in O/S Makesurethedeviceissupportedbyyouroperatingsystem.
3. Transfer speed is slow IfthedeviceisconnectedviatheUSB2.0interface,thespeedwillbearound30MB/sec only.
4. When formatting under Windows XP/ Vista/ 7, the dialog box “Unfinished formatting” is displayed WindowsXP/Vista/7cannotformatHDDswithcapacitiesabove32GBintoFAT32, pleasechooseNTFSasdataformat.
8-bay raid station 18
5. When the system is damaged in LARGE mode, is it still possible to read the data? No.ThesystemisdifferentfromaRAID;theentirediskcannotberead.
11. Appendix
11.1. CLEAN mode
Function:InCLEANmodeeachharddriveisdisplayedseparatelyasonedrive.
Notes: When using a SATA host controller, CLEAN mode should only be used if the SATA host controller provides Port Multiplier (PM) support. If a host is not PM-aware, only a single drive is displayed (drive 1). The CLEAN mode will not delete the drives partition if the drives were used as single drive before.
8-bay raid station 19
11.2 LARGE mode
Function: TheLARGEmodeconcatenatesaseriesofphysicalharddrivesintoasinglelarge volume,creatingaseamlessexpansionofvirtualvolumesbeyondthephysicallimitations of singularly connected hard drives.
Notes: The hard drives 1 to 8 are concatenated into a single virtual volume in the Figure above with a storage capacity that is equal to the sum of each of the physical hard drives 1 to 8. It is also possible to create a LARGE volume using only a single hard disk drive connected to Port 1. However, it is not possible to expand an existing LARGE volume by adding another hard disk drive and still preserve any existing data on that volume.
8-bay raid station 20
11.3 R00 mode
Function: InR00modethedataisspreadacrossallharddisks.
Example1
Advantage/disadvantage: R00moderepresentsthebestdataspeedbutnodataredundancy.R00modeaccelerates harddiskdriveoperatingspeedbyusingmanydiskssimultaneously. ToimplementtheR00mode,the8-BAYRAIDSTATIONStoragecreatestwosinglevirtual volumes(SYS1andSYS2)thatarestripedacrossallharddrivesofSYS1andSYS2,with astoragecapacitythatisfourtimesofthesmallestdrive.SYS1andSYS2arethen stripedagainacrossbothvirtualvolumes.Thestoragecapacityistwicethecapacity of the smallest virtual volume.
8-bay raid station 21
TheR00modecanalsobeimplementedusingasingledisk: Example2
8-bay raid station 22
11.4 R30 mode
Function: TheR30modeaddsfaulttolerancetodrivestripingbyaddingparityinformationtothe data.R30modededicatestheequivalentoftwodrives(SYS1andSYS2)forstoring parityinformationandtostripetheseagain.Thedataandparityinformationisarranged onthedrivearraysothatparityiswrittentotwodrives.Thefollowingexampleillustrates how the parity is rotated from drive to drive.
8-bay raid station 23
Advantage/disadvantage: TheR30modeuseslesscapacityforprotectionandisthepreferredmethodtoreduce thecostpermegabyteforlargerinstallations. Inexchangeforlowoverheadnecessarytoimplementprotection,theR30mode degradesperformanceforallwriteoperations.TheparitycalculationsforR30modemay result in write performance that is somewhat slower than the write performance to a single drive. TheresultingstoragecapacityofthevirtualR30volumewillbe“nminus2”-times (n=numberofdisks)ofthesmallestdrive.
Ifonedrivefails,thevirtualR30volumeisstillusable.Whentheofflinedrivecomesback online,theappliancebeginsarebuildprocessimmediatelytorestoredataredundancy. DuringthisproceduretheLEDindicationswillnotifyyouthatarebuildisinprogress.
Notes: Although the volume remains available during the rebuild process, the volume is susceptible to data loss through damage to the remaining drive until redundancy is restored at the end of the rebuild and verification process. Host access takes precedence over the rebuild process. If you continue to use the virtual R3 volume during the rebuild, the rebuild process will take a longer time to complete, and the host data transfer performance will also be affected.
8-bay raid station 24
TheR30modecanalsobeimplementedusingasingledisk:
11.5 R50 mode
Function: TheR50modeaddsfaulttolerancetodrivestripingbyincludingparityinformationwith thedata.R50modededicatestheequivalentofonedriveforstoringparitystripes.The data and parity information is arranged on the drive array so that parity is written to all drives(SYS1and2).Thefollowingexampleillustrateshowtheparityisrotatedfrom drive to drive.
8-bay raid station 25
Advantage/disadvantage: TheR50modeuseslesscapacityforprotectionandisthepreferredmethodtoreduce thecostpermegabyteforlargerinstallations. Inexchangeforlowoverheadnecessarytoimplementprotection,theR50modedegrades performanceforallwriteoperations.TheparitycalculationsforR50modemayresultin write performance that is somewhat slower. TheresultingstoragecapacityofthevirtualR50volumewillbe“nminus2”-times (n=numberofdisks)ofthesmallestdrivecapacity.
Ifonedrivefails,thevirtualR50volumeisstillusable,butitisinavulnerablestate becauseitsmirroredharddriveisinaccessible.Whentheofflinedrivecomesbackonline, theappliancebeginsarebuildprocessimmediatelytorestoredataredundancy.During thisproceduretheLEDindicationswillnotifyyouthatarebuildisinprogress.
Notes: Although the volume remains available during the rebuild process, the volume is susceptible to data loss through damage to the remaining drive until redundancy is restored at the end of the rebuild and verification process. Host access takes precedence over the rebuild process. If you continue to use the virtual R5 volume during the rebuild, the rebuild process will take a longer time to complete, and the host data transfer performance will also be affected.
8-bay raid station 26
TheR50modecanalsobeimplementedusingasingledisk:
8-bay raid station 27
Legal disclaimer:
Forpotentiallossofdata,especiallyduetoinappropriatehandling,SHARKOONassumesnoliability.Allnamedproductsanddescriptionsaretrademarksand/orregisteredtrademarksoftherespective manufacturers and are accepted as protected.
AsacontinuingpolicyofproductimprovementatSHARKOON,thedesignandspecificationsaresubjecttochangewithoutpriornotice.Nationalproductspecificationsmayvary.
Allrightsreservedespecially(alsoinextracts)fortranslation,reprinting,reproductionbycopyingorothertechnicalmeans.Infringementswillleadtocompensation.
Allrightsreservedespeciallyincaseofassignationofpatentorutilitypatent.Meansof deliveryandtechnicalmodificationsreserved.
Disposal of your old product Yourproductisdesignedandmanufacturedwithhighqualitymaterialsandcomponents,whichcanberecycledandreused.
Whenthiscrossed-outwheeledbinsymbolisattachedtoaproduct,itmeanstheproductiscoveredbytheEuropeanDirective2002/96/EC.Pleasebeinformedaboutthelocalseparatecollectionsystemforelectricalandelectronicproducts.Pleaseactaccordingtoyourlocalrulesanddonotdisposeofyouroldproductswithyournormalhouseholdwaste.Thecorrectdisposalofyouroldproductwillhelppreventpotenti-al negative consequences to the environment and human health.
© SHARKOON Technologies 2012www.sharkoon.com
top related