3900 series base station cables(v100r009c00_draft c)(pdf)-en
Post on 12-Sep-2015
198 Views
Preview:
DESCRIPTION
TRANSCRIPT
-
3900 Series Base StationV100R009C00
Cables
Issue Draft CDate 2014-03-26
HUAWEI TECHNOLOGIES CO., LTD.
-
Copyright Huawei Technologies Co., Ltd. 2014. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior writtenconsent of Huawei Technologies Co., Ltd. Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respective holders. NoticeThe purchased products, services and features are stipulated by the contract made between Huawei and thecustomer. All or part of the products, services and features described in this document may not be within thepurchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,and recommendations in this document are provided "AS IS" without warranties, guarantees or representationsof any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in thepreparation of this document to ensure accuracy of the contents, but all statements, information, andrecommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd.Address: Huawei Industrial Base
Bantian, LonggangShenzhen 518129People's Republic of China
Website: http://www.huawei.comEmail: support@huawei.com
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
i
-
About This Document
OverviewThis document describes information about the cables for the cabinets used in 3900 series basestations. It provides cable lists and illustrates the cable connections and all related cables. Forthe details about the RRU or AAU cables, see the related manual of RRU or AAU hardwaredescription.The exteriors of components or cables in this document are for reference only. The actualexteriors may be different.
NOTE
If LTE is used rather than LTE FDD or LTE TDD in this document, the LTE mode can be the LTE FDD modeor LTE TDD mode. If eNodeB is used rather than eNodeB FDD or eNodeB TDD in this document, the eNodeBcan be an eNodeB FDD or a eNodeB TDD.For details about the LampSite solution, see LampSite Hardware Description.
Product VersionThe following table lists the product versions related to this document.
Product Name Product VersionBTS3900 V100R009C00
The mapping single-mode base station versions are:GBTS: V100R016C00eGBTS: V100R016C00NodeB: V200R016C00eNodeB: V100R007C00
BTS3900ABTS3900LBTS3900ALDBS3900BTS3900C V100R009C00
The mapping single-mode base station version is:NodeB: V200R016C00
3900 Series Base StationCables About This Document
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
ii
-
Intended AudienceThis document is intended for:l System engineersl Base station installation engineersl Site maintenance personnel
Organization1 Changes in 3900 Series Base Station CablesThis chapter describes changes in 3900 Series Base Station Cable Description of each version.2 Cable ListThis chapter describes cable lists for BTS3900, BTS3900L, BTS3900A, BTS3900AL, andBTS3900C base stations.3 Cable ConnectionsThis chapter describes cable connections for 3900 series base station, including power cableconnections, transmission cable connections, monitoring signal cable connections, BBUinterconnection signal cable connections, CPRI cable connections, and RF cable connections.4 PGND CablesPGND cables are classified into PGND cables for cabinets and PGND cables for modules. PGNDcables ensure that cabinets and internal modules are properly grounded and that base stationsrun properly.5 Equipotential CablesEquipotential cables connect the PGND terminals of two cabinets. Equipotential cables ensurethat cabinets are equipotential and that base stations run properly.6 Power CablesThis section describes the exteriors, functions, and pin assignment of power cables in BTS3900Acabinets.7 Transmission CablesThis section describes the exteriors, functions, pin assignment of the transmission cables in acabinet.8 Signal CablesThis section describes the exteriors, functions, pin assignment of all signal cables in BTS3900Acabinets.9 CPRI CablesThis section describes CPRI cables, including CPRI electrical cables and CPRI fiber optic cables.10 RF Cables
3900 Series Base StationCables About This Document
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
iii
-
This chapter describes the RF cables, including RF jumpers and inter-RFU RF signal cables.
ConventionsSymbol ConventionsThe symbols that may be found in this document are defined as follows.
Symbol DescriptionIndicates an imminently hazardous situation which, if notavoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if notavoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if notavoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if notavoided, could result in equipment damage, data loss,performance deterioration, or unanticipated results.NOTICE is used to address practices not related to personalinjury.Calls attention to important information, best practices andtips.NOTE is used to address information not related to personalinjury, equipment damage, and environment deterioration.
General ConventionsThe general conventions that may be found in this document are defined as follows.
Convention DescriptionTimes New Roman Normal paragraphs are in Times New Roman.Boldface Names of files, directories, folders, and users are in
boldface. For example, log in as user root.Italic Book titles are in italics.Courier New Examples of information displayed on the screen are in
Courier New.
Command ConventionsThe command conventions that may be found in this document are defined as follows.
3900 Series Base StationCables About This Document
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
iv
-
Convention DescriptionBoldface The keywords of a command line are in boldface.Italic Command arguments are in italics.[ ] Items (keywords or arguments) in brackets [ ] are optional.{ x | y | ... } Optional items are grouped in braces and separated by
vertical bars. One item is selected.[ x | y | ... ] Optional items are grouped in brackets and separated by
vertical bars. One item is selected or no item is selected.{ x | y | ... }* Optional items are grouped in braces and separated by
vertical bars. A minimum of one item or a maximum of allitems can be selected.
[ x | y | ... ]* Optional items are grouped in brackets and separated byvertical bars. Several items or no item can be selected.
GUI ConventionsThe GUI conventions that may be found in this document are defined as follows.
Convention DescriptionBoldface Buttons, menus, parameters, tabs, window, and dialog titles
are in boldface. For example, click OK.> Multi-level menus are in boldface and separated by the ">"
signs. For example, choose File > Create > Folder.
Keyboard OperationsThe keyboard operations that may be found in this document are defined as follows.
Format DescriptionKey Press the key. For example, press Enter and press Tab.Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl+Alt
+A means the three keys should be pressed concurrently.Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A means
the two keys should be pressed in turn.
Mouse OperationsThe mouse operations that may be found in this document are defined as follows.
3900 Series Base StationCables About This Document
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
v
-
Action DescriptionClick Select and release the primary mouse button without moving
the pointer.Double-click Press the primary mouse button twice continuously and
quickly without moving the pointer.Drag Press and hold the primary mouse button and move the
pointer to a certain position.
3900 Series Base StationCables About This Document
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
vi
-
Contents
About This Document.....................................................................................................................ii1 Changes in 3900 Series Base Station Cables............................................................................12 Cable List.........................................................................................................................................42.1 BTS3900 Cable List.......................................................................................................................................................52.1.1 BTS3900 (Ver.B) Cable List.......................................................................................................................................52.1.2 BTS3900 (Ver.C) Cable List.....................................................................................................................................122.1.3 BTS3900 (Ver.D) Cable List.....................................................................................................................................192.2 BTS3900L Cable List...................................................................................................................................................292.2.1 BTS3900L (Ver.B) Cable List...................................................................................................................................292.2.2 BTS3900L (Ver.C) Cable List...................................................................................................................................362.2.3 BTS3900L (Ver.D) Cable List..................................................................................................................................442.3 BTS3900A Cable List..................................................................................................................................................522.3.1 BTS3900A (Ver.B) Cable List..................................................................................................................................522.3.2 BTS3900A (Ver.C) Cable List..................................................................................................................................632.3.3 BTS3900A (Ver.D) Cable List..................................................................................................................................752.3.4 BTS3900A(Ver.D_A2) Cable List............................................................................................................................872.3.5 BTS3900A(Ver.D_A1) Cable List............................................................................................................................922.4 BTS3900AL Cable List................................................................................................................................................982.4.1 BTS3900AL (Ver.A) Cable List...............................................................................................................................982.5 DBS3900 Cable Lists.................................................................................................................................................1102.6 BTS3900C Cable List.................................................................................................................................................1152.6.1 BTS3900C WCDMA Cable List.............................................................................................................................1152.6.2 BTS3900C (Ver.C) Cable List................................................................................................................................1213 Cable Connections.....................................................................................................................1293.1 Power Cable Connections...........................................................................................................................................1303.1.1 BTS3900 Power Cable Connections.......................................................................................................................1303.1.2 BTS3900L Power Cable Connections.....................................................................................................................1413.1.3 BTS3900A Power Cable Connections....................................................................................................................1463.1.4 BTS3900AL Power Cable Connections..................................................................................................................1713.1.5 Power Cable Connections in a DBS3900................................................................................................................1763.1.6 BTS3900C Power Cable Connections.....................................................................................................................214
3900 Series Base StationCables Contents
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
vii
-
3.2 Transmission Cable Connections...............................................................................................................................2183.2.1 Transmission Cable Connections for a Single-Mode Base Station.........................................................................2183.2.2 Transmission Cable Connections for a Dual-Mode Base Station Using the Co-Transmission Function...............2293.2.3 Transmission Cable Connections for a Dual-Mode Base Station Using the Separate-Transmission Function..........................................................................................................................................................................................2433.2.4 Transmission Cable Connections for a Triple-Mode Base Station.........................................................................2523.2.5 Transmission Cable Connections for a Quadruple-Mode Base Station..................................................................2573.3 Monitoring Signal Cable Connections.......................................................................................................................2583.3.1 BTS3900 Monitoring Signal Cable Connections....................................................................................................2593.3.2 BTS3900L Monitoring Signal Cable Connections..................................................................................................2713.3.3 BTS3900A Monitoring Signal Cable Connections.................................................................................................2773.3.4 BTS3900AL Monitoring Signal Cable Connections...............................................................................................3033.3.5 Monitoring Signal Cable Connections in a DBS3900.............................................................................................3103.3.6 BTS3900C Monitoring Signal Cable Connections.................................................................................................3413.4 Inter-BBU Signal Cable Connections.........................................................................................................................3453.5 CPRI Cable Connections............................................................................................................................................3483.5.1 CPRI Cable Connections for a GSM Base Station..................................................................................................3483.5.2 CPRI Cable Connections for a UMTS Base Station...............................................................................................3523.5.3 CPRI Cable Connections for an LTE FDD and an LTE TDD Base Stations.........................................................3553.5.4 CPRI Cable Connections for a GU and a G*U Base Stations.................................................................................3583.5.5 CPRI Cable Connections for a GL and a G*L Base Stations..................................................................................3643.5.6 CPRI Cable Connections for a UL and a U*L Base Stations..................................................................................3703.5.7 CPRI Cable Connections for a Triple-Mode Base Station......................................................................................3763.5.8 CPRI Cable Connections for a Quadruple-Mode Base Station...............................................................................3873.6 RF Cable Connections................................................................................................................................................3903.6.1 RF Cable Connection Description...........................................................................................................................3913.6.2 RF Cable Connections for the DRFU......................................................................................................................3933.6.3 RF Cable Connections for the GRFU......................................................................................................................3943.6.4 RF Cable Connections for the WRFU.....................................................................................................................3953.6.5 RF Cable Connections for the WRFUa...................................................................................................................3963.6.6 RF Cable Connections for the WRFUd...................................................................................................................3973.6.7 RF Cable Connections for the WRFUe...................................................................................................................3983.6.8 RF Cable Connections for the LRFU......................................................................................................................3993.6.9 RF Cable Connections for the LRFUe....................................................................................................................4003.6.10 RF Cable Connections for the MRFU...................................................................................................................4013.6.11 RF Cable Connections for the MRFUd.................................................................................................................4023.6.12 RF Cable Connections for the MRFUe.................................................................................................................4033.6.13 RF Cable Connections for the CRFUd..................................................................................................................4043.6.14 RF Cable Connections for the CRFUe..................................................................................................................4053.6.15 RF Cable Connections for Mixed RFU Configuration..........................................................................................4064 PGND Cables.............................................................................................................................409
3900 Series Base StationCables Contents
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
viii
-
5 Equipotential Cables.................................................................................................................4126 Power Cables..............................................................................................................................4146.1 Power Cables for Power Supply Devices...................................................................................................................4156.1.1 DCDU Power Cables...............................................................................................................................................4156.1.2 EPU/EPS/ETP Power Cables..................................................................................................................................4346.1.3 PDU Power Cables..................................................................................................................................................4526.1.4 Power Cables for Other Power Supply Devices......................................................................................................4576.2 Power Cables for Monitoring Devices.......................................................................................................................4666.2.1 CMUEA Power Cable.............................................................................................................................................4666.2.2 CMUF Power Cable................................................................................................................................................4676.2.3 CCU Power Cable...................................................................................................................................................4686.2.4 HEUA Power Cable.................................................................................................................................................4696.2.5 HEUB Power Cable.................................................................................................................................................4706.3 Power Cables for Temperature Control Devices........................................................................................................4716.3.1 Power Cables for Fan Assemblies...........................................................................................................................4716.3.2 FAU03D-01 Power Cable.......................................................................................................................................4796.3.3 FAU03D-02 Power Cable.......................................................................................................................................4806.3.4 Power Cables for an AC Heater..............................................................................................................................4816.3.5 Power Cable for a Heating Film..............................................................................................................................4836.3.6 Transfer Cable for the Fan in the Front Door..........................................................................................................4846.3.7 Power Cables for the Temperature Control System................................................................................................4856.3.8 HAU01A-01 Power Cable.......................................................................................................................................4866.3.9 Fan Power Cables in an IBBS200D........................................................................................................................4866.3.10 TEC Power Cables in an IBBS200T.....................................................................................................................4896.3.11 Power Cable for a Heat Exchanger in the Front Door...........................................................................................4926.4 Power Cables for Other Devices................................................................................................................................4936.4.1 EMUA/EMUB Power Cable...................................................................................................................................4936.4.2 BBU Power Cable...................................................................................................................................................4956.4.3 RFU Power Cables..................................................................................................................................................4976.4.4 RRU Power Cables..................................................................................................................................................4996.4.5 SOU Power Cable....................................................................................................................................................5016.4.6 SPD Power Cable....................................................................................................................................................5026.4.7 Power Cable for an AC Surge Protection Box........................................................................................................5036.4.8 GATM Power Cable................................................................................................................................................5046.4.9 ODM06D Power Cable...........................................................................................................................................5077 Transmission Cables.................................................................................................................5087.1 E1/T1 Cable................................................................................................................................................................5107.2 E1/T1 Surge Protection Transfer Cable......................................................................................................................5137.3 FE/GE Fiber Optic Cable...........................................................................................................................................5147.4 Interconnection Cable Between FE/GE Electrical Ports............................................................................................515
3900 Series Base StationCables Contents
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
ix
-
7.5 Interconnection Cable Between FE/GE Optical Ports................................................................................................5157.6 FE/GE Ethernet Cable................................................................................................................................................5167.7 FE/GE Surge Protection Transfer Cable....................................................................................................................5178 Signal Cables..............................................................................................................................5198.1 Signal Cables for Power Devices...............................................................................................................................5208.1.1 PMU-CCU Monitoring Signal Cable......................................................................................................................5208.1.2 PMU 11A-CMUEA Monitoring Signal Cable........................................................................................................5218.1.3 PMU 01B-BBU Monitoring Signal Cable...............................................................................................................5218.1.4 PMU 11A-BBU Monitoring Signal Cable..............................................................................................................5228.1.5 PMU 11A-HEUB Monitoring Signal Cable............................................................................................................5238.1.6 Surge Protection Alarm Cable for the DCDU-13A.................................................................................................5248.1.7 Monitoring Signal Cable for the DCDU-03B..........................................................................................................5258.1.8 PSU (EPW25-24S48D) Monitoring Signal Cable...................................................................................................5258.1.9 PSU (EPW25-24S48D) In-Position Signal Cable...................................................................................................5268.2 Signal Cables for Monitoring Devices.......................................................................................................................5278.2.1 PMU-HEUA Monitoring Signal Cable...................................................................................................................5278.2.2 APMI-BBU Monitoring Signal Cable.....................................................................................................................5288.2.3 Signal Cables for connecting Cascaded CCUs........................................................................................................5298.2.4 CCU-BBU Monitoring Signal Cable.......................................................................................................................5308.2.5 Monitoring Signal Cable between Cascaded CMUAs............................................................................................5318.2.6 Monitoring Signal Cable Between Cascaded CMUEs............................................................................................5328.2.7 Monitoring Signal Cable Between Cascaded CMUEAs.........................................................................................5338.2.8 Signal Cables for connecting Cascaded HAU01A-01s...........................................................................................5348.2.9 HEUB-BBU Monitoring Signal Cable....................................................................................................................5358.2.10 HEUA-BBU Monitoring Signal Cable..................................................................................................................5368.2.11 CMUEA-CCU Monitoring Signal Cable..............................................................................................................5368.2.12 CMUF-CCU Monitoring Signal Cable..................................................................................................................5378.2.13 CMUEA-BBU Monitoring Signal Cable..............................................................................................................5388.2.14 HAU01A-01 Monitoring Signal Cable..................................................................................................................5398.2.15 FMUC-BBU Monitoring Signal Cable..................................................................................................................5408.2.16 FMUE-BBU Monitoring Signal Cable..................................................................................................................5418.2.17 FMUEA-BBU Monitoring Signal Cable...............................................................................................................5428.2.18 Monitoring Signal Cable for the Battery Cabinet..................................................................................................5438.2.19 BBU Alarm Cable.................................................................................................................................................5448.3 Signal Cables for Temperature Control Devices........................................................................................................5468.3.1 Monitoring Signal Cable Between Cascaded Fan Assemblies................................................................................5468.3.2 FAU03D-01 Monitoring Signal Cable....................................................................................................................5478.3.3 FAU03D-02 Monitoring Signal Cable....................................................................................................................5488.3.4 Monitoring Signal Cable Between Cascaded FANs................................................................................................5498.3.5 HEUB-FAU01D-01 Monitoring Signal Cable........................................................................................................5508.3.6 Monitoring Signal Cable Between Cascaded FAN 03B Units................................................................................551
3900 Series Base StationCables Contents
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
x
-
8.3.7 Monitoring Signal Cable Between Cascaded FAN 03C Units................................................................................5528.3.8 Monitoring Signal Cable for the OMB Fan Assembly............................................................................................5538.3.9 Monitoring Signal Cables for the Temperature Sensor...........................................................................................5538.3.10 HAU01A-01 Monitoring Signal Cable..................................................................................................................5558.3.11 Monitoring Signal Transfer Cable for the Fan in the Front Door.........................................................................5578.3.12 Monitoring Signal Cable for the Heat Exchanger.................................................................................................5588.3.13 TEC Alarm Transfer Cable for the IBBS2.2.........................................................................................................5598.4 Signal Cables for Other Devices................................................................................................................................5608.4.1 Monitoring Signal Cable for the Door Status Sensor..............................................................................................5608.4.2 ELU Signal Cable....................................................................................................................................................5638.4.3 Monitoring Signal Cables for the IBBS Door Control and Temperature Sensor....................................................5658.4.4 EMUA/EMUB Monitoring Signal Cable................................................................................................................5668.4.5 EMU Monitoring Signal Cable................................................................................................................................5678.4.6 Monitoring Signal Cable for the AC Surge Protection Module..............................................................................5688.4.7 Alarm Signal Cable for the AC Surge Protection Box............................................................................................5698.4.8 Monitoring Signal Cable for the Surge Protection Box..........................................................................................5698.4.9 RRU AISG Multi-Wire Cable.................................................................................................................................5708.4.10 RRU AISG Extension Cable.................................................................................................................................5718.4.11 GPS Clock Signal Cable........................................................................................................................................5728.4.12 GPS Jumper...........................................................................................................................................................5728.4.13 Inter-BBU Signal Cables.......................................................................................................................................5738.4.14 Cable Between Two Combined Base Stations......................................................................................................5758.4.15 Adapter Used for Local Maintenance....................................................................................................................5768.4.16 GATM Monitoring Signal Cable...........................................................................................................................5778.4.17 CMUA-GATM Monitoring Signal Cable.............................................................................................................5788.4.18 CMUE-GATM Monitoring Signal Cable..............................................................................................................5798.4.19 CMUEA-GATM Monitoring Signal Cable...........................................................................................................5808.4.20 FMUC-GATM Monitoring Signal Cable..............................................................................................................5818.4.21 FMUE-GATM Monitoring Signal Cable..............................................................................................................5828.4.22 RET Control Signal Cable.....................................................................................................................................5838.4.23 ODM06D Surge Protection Alarm Cable..............................................................................................................5849 CPRI Cables................................................................................................................................5859.1 CPRI Electrical Cable.................................................................................................................................................5869.2 CPRI Fiber Optic Cable..............................................................................................................................................58610 RF Cables...................................................................................................................................59110.1 RF Jumpers...............................................................................................................................................................59210.2 Inter-RFU RF Signal Cable......................................................................................................................................593
3900 Series Base StationCables Contents
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
xi
-
1 Changes in 3900 Series Base Station CablesThis chapter describes changes in 3900 Series Base Station Cable Description of each version.
Draft C (2014-03-26)This is a draft.Compared with the issues Draft B (2014-02-28), this issue is added with the following topics:l Power Cable Connections in an IBC10 Used by a DBS3900l Monitoring Signal Cable Connections in an IBC10 Used by a DBS3900l 6.3.3 FAU03D-02 Power Cablel 8.3.3 FAU03D-02 Monitoring Signal CableCompared with the issues Draft B (2014-02-28), this issue includes the following changes.
Topic Change DescriptionDCDU-12C Power Cables Added the descriptions of the IBC10.4 PGND Cables8.3.9 Monitoring Signal Cables for theTemperature Sensor
Compared with the issues Draft B (2014-02-28), no topic is deleted from this issue.
Draft B (2014-02-28)This is a draft.Compared with the issues Draft A (2014-01-20), this issue does not include any new informationand does not exclude any information.Compared with the issues Draft A (2014-01-20), this issue includes the following changes.
3900 Series Base StationCables 1 Changes in 3900 Series Base Station Cables
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
1
-
Topic Change DescriptionAbout This Document Added the description of the LampSite
solution.
Darft A (2014-01-20)This is a draft.Compared with multimode base station version V100R008C00, WCDMA-NodeBV200R015C00, GSM-BTS V100R015C00, eNodeB V100R006C00, this issue is added with thefollowing topics:l 2.5 DBS3900 Cable Listsl Power Cable for the DC Junction Box in a BTS3900ALl 6.4.9 ODM06D Power Cablel 8.4.23 ODM06D Surge Protection Alarm CableCompared with multimode base station version V100R008C00, WCDMA-NodeBV200R015C00, GSM-BTS V100R015C00, eNodeB V100R006C00, this issue incorporates thefollowing changes:
Topic Change Descriptionl 3.2 Transmission Cable Connections
and its child topics.l 3.5 CPRI Cable Connections and its
child topics.
Added the cable connections when BBU3910is configured.
l 2.3.1 BTS3900A (Ver.B) Cable Listl 2.3.2 BTS3900A (Ver.C) Cable Listl 2.3.3 BTS3900A (Ver.D) Cable Listl 2.4.1 BTS3900AL (Ver.A) Cable Listl 6.4.1 EMUA/EMUB Power Cablel 8.4.4 EMUA/EMUB Monitoring Signal
Cable
Added the EMUB power cable and EMUBmonitoring signal cable.
The whole document Renamed all EPC6 connectors in thisdocument EPC4 connectors.
l 2.1.3 BTS3900 (Ver.D) Cable Listl 2.2.3 BTS3900L (Ver.D) Cable List
Added the cables when the BTS3900 (Ver.D)and BTS3900L (Ver.D) use the IMS06.
3900 Series Base StationCables 1 Changes in 3900 Series Base Station Cables
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
2
-
Topic Change Descriptionl BTS3900 (Ver.D) Power Cable
Connectionsl BTS3900 (Ver.D) Monitoring Signal
Cable Connectionsl BTS3900L (Ver.D) Power Cable
Connectionsl BTS3900L (Ver.D) Monitoring Signal
Cable Connections
Added the cable connections when theBTS3900 (Ver.D) and BTS3900L (Ver.D)use the IMS06.
l 2.1.2 BTS3900 (Ver.C) Cable Listl 2.2.2 BTS3900L (Ver.C) Cable List
Deleted the DCDU-12B power cable.
DCDU-11B Power Cable Deleted scenarios where a DCDU-11B isinstalled in a cabinet.
DCDU-12B Power Cable Deleted scenarios where a DCDU-12B isinstalled on a wall.
Compared with multimode base station version V100R008C00, WCDMA-NodeBV200R015C00, GSM-BTS V100R015C00, eNodeB V100R006C00, this issue excludes thefollowing information:l BusBar Power Cablesl EPU03A-20 Power Cables
3900 Series Base StationCables 1 Changes in 3900 Series Base Station Cables
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
3
-
2 Cable ListAbout This Chapter
This chapter describes cable lists for BTS3900, BTS3900L, BTS3900A, BTS3900AL, andBTS3900C base stations.
2.1 BTS3900 Cable ListThis section describes cable lists when the BTS3900 is configured with BTS3900 (Ver.B),BTS3900 (Ver.C), and BTS3900 (Ver.D) cabinets.2.2 BTS3900L Cable ListThis section describes cable lists when the BTS3900L is configured with BTS3900L (Ver.B),BTS3900L (Ver.C), and BTS3900L (Ver.D) cabinets.2.3 BTS3900A Cable ListThis section describes cable lists when the BTS3900A is configured with BTS3900A (Ver.B),BTS3900A (Ver.C), BTS3900A(Ver.D), and enhanced cabinets.2.4 BTS3900AL Cable ListThis section describes the list of BTS3900AL cables.2.5 DBS3900 Cable ListsThe DBS3900 cable lists include the lists of cables for the cabinets used by the DBS3900, BBUcable list, and RRU cable list.2.6 BTS3900C Cable ListThis section describes cable lists when the BTS3900C is configured with different types ofcabinets.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
4
-
2.1 BTS3900 Cable ListThis section describes cable lists when the BTS3900 is configured with BTS3900 (Ver.B),BTS3900 (Ver.C), and BTS3900 (Ver.D) cabinets.
2.1.1 BTS3900 (Ver.B) Cable ListThe BTS3900 cables include PGND cables, equipotential cable, power cables, transmissioncables, signal cables, CPRI electrical cables, and RF cables.
PGND Cables and Equipotential CableThe following table describes the PGND cables and equipotential cable.
Table 2-1 PGND cables and equipotential cableCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
PGND cablefor thecabinet
OT terminal Groundterminal onthe cabinet
OT terminal Externalground bar
5Equipotential Cables
OT terminal Wiringterminal fortheequipotential cable
OT terminal Wiringterminal fortheequipotentialcable
Cablesinstalledbeforedelivery
PGND cablefor a module
OT terminal Groundterminal on amodule
OT terminal Groundterminal forthe PGNDcable in thecabinet
Power CablesThe following table describes the power cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
5
-
Table 2-2 Power cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
DCDU-01PowerCable
OT terminal l Blackwire:RTN(+)terminalon theDCDU-01
l Bluewire:NEG(-)terminalon theDCDU-01
Dependingon theexternalpowerequipment
Externalpowerequipment
EPS24S48100DC PowerCable
OT terminal Power inputterminal fortheEPS24S48100DCsubrack
Dependingon theexternalpowerequipment
Externalpowerequipment
EPS4890PowerCable
OT terminal Power inputterminal forthe EPS4890subrack
Dependingon theexternalpowerequipment
Externalpowerequipment
6.4.4 RRUPowerCables
OT terminal One of theLOAD0 toLOAD5ports on theDCDU-03B
Dependingon the RRUmodel
Power porton an RRU
GATMPowerCable
3V3connector
-48V port onthe GATM
Parallelterminal
SPARE1 orSPARE2port on theDCDU-01
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
6
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n PositionDCDU-03BPowerCable
OT terminal l Blackwire:RTN(+)terminalon theDCDU-03B
l Bluewire:NEG(-)terminalon theDCDU-03B
Dependingon theexternalpowerequipment
Externalpowerequipment
Cablesinstalledbeforedelivery
6.4.3 RFUPowerCables
3V3connector
PWR port onan RFU
Parallelterminal
One of theRFU0 toRFU5 portson theDCDU-01
FAN PowerCables
3V3connector
-48V port onthe FAN
Parallelterminal
FAN port ontheDCDU-01
6.4.2 BBUPowerCable
3V3connector
-48V port onthe UPEU
Parallelterminal
BBU port ontheDCDU-01
DCDU-01PowerCableFor theBTS3900+24V DCcabinet
OT terminal RTN(+) andNEG(-)terminals ontheDCDU-01
OT terminal RTN(+) andLOAD(-)terminals ontheEPS24S48100DCsubrack
DCDU-01PowerCableFor theBTS3900AC cabinet
OT terminal RTN(+) andNEG(-)terminals ontheDCDU-01
OT terminal LOAD1(-) orLOAD2(-)and RTN(+)terminals onthe EPS4890subrack
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
7
-
Transmission CablesThe following table describes the transmission cables.
Table 2-3 Transmission cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
7.1 E1/T1Cable
DB26 maleconnector
E1/T1 porton theGTMU,WMPT, orUTRP
Dependingon theexternalequipment
Externaltransmissionequipment
7.6 FE/GEEthernetCable
RJ45connector
FE0 port onthe GTMU,WMPT,UMPT,LMPT, orUTRP
RJ45connector
Routingdevice
7.3 FE/GEFiber OpticCable
LCconnector
SFP0 orSFP1 port onthe GTMU,WMPT,UMPT, orUTRP
l FCconnector
l SCconnector
l LCconnector
Routingdevice
Cablesinstalledbeforedelivery
7.4Interconnection CableBetweenFE/GEElectricalPorts
RJ45connector
FE0 port onthe GTMU
RJ45connector
FE0 port onthe WMPT
7.5Interconnection CableBetweenFE/GEOpticalPorts
LCconnector
FE1 port onthe GTMU
LCconnector
FE1 port onthe WMPT
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
8
-
Signal CablesThe following table describes the signal cables.
Table 2-4 Signal cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
8.4.5 EMUMonitoringSignalCable
DB9 maleconnector
RS485 porton the EMU
RJ45connector
MON1 porton the UPEUor UEIU
8.2.19 BBUAlarmCable
RJ45connector
EXT-ALM0port on theUPEU orUEIU
RJ45connector
Externalalarm device
8.4.11 GPSClockSignalCable
SMA maleconnector
GPS port onthe USCU
Type Nfemaleconnector
GPS surgeprotector
RETControlSignalCable
SMA elbowmaleconnector
ANT0 toANT5 portson theGATM
SMA straightmaleconnector
DC/OOKport on theDIN Bias-Tee
GATMMonitoringSignalCable
RJ45connector
COM1 porton theGATM
RJ45connector
MON1 porton the UPEUor MON0port on theUEIU
FMUC-GATMMonitoringSignalCable
RJ45connector
COM2 porton theGATM
RJ45connector
COM_INport on thelower-levelFAN
8.4.15AdapterUsed forLocalMaintenance
USBconnector
USB(1) porton theUMPT in theBBU
Networkconnector
Networkcable
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
9
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n PositionCablesinstalledbeforedelivery
8.1.3 PMU01B-BBUMonitoringSignalCable
RJ45connector
COM_INport on thePMU 01B
RJ45connector
MON1 porton the UPEU
8.1.9 PSU(EPW25-24S48D) In-PositionSignalCable
Cord endterminal
ALMterminal ontheEPS24S48100DCsubrack
RJ45connector
EXT-ALM0port on theUPEU
8.1.8 PSU(EPW25-24S48D)MonitoringSignalCable
RJ45connector
PRESENTport on theEPS24S48100DCsubrack
RJ45connector
EXT-ALM1port on theUPEU
8.2.15FMUC-BBUMonitoringSignalCable
RJ45connector
COM_INport on theFAN
RJ45connector
MON0 porton the UPEUor UEIU
8.3.4MonitoringSignalCableBetweenCascadedFANs
RJ45connector
COM_OUTport on theupper-levelFANNOTE
The upper-level FANcommunicates with theBBUdirectly.
RJ45connector
COM_INport on thelower-levelFANNOTE
The lower-level FANcommunicates with theBBUthrough theupper-levelFAN.
8.4.2 ELUSignalCable
RJ45connector
ELU RJ45connector
SENSORport on theFAN
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
10
-
NOTE
a: The security of the USB port is ensured by encryption, and the USB port can be shut down usingcommands. The USB commission port is used for commissioning the base station rather than configuringand exporting information of the base station.
CPRI Electrical CablesThe following table describes the CPRI electrical cables.
Table 2-5 CPRI electrical cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
9.1 CPRIElectricalCable
SFP20 maleconnector
CPRI port onthe GTMU,UBRI,WBBP, orLBBP
SFP20 maleconnector
CPRI port onan RFU
Cablesinstalledbeforedelivery
If boards and modules have been installed in a BTS3900 cabinet beforedelivery, CPRI electrical cables are also installed in the cabinet beforedelivery. In this case, only the CPRI electrical cables between BTS3900cabinets must be installed onsite.
RF CablesThe following table describes the RF cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
11
-
Table 2-6 RF cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
10.1 RFJumpers
DIN elbowmaleconnector
ANT_TX/RXA orANT_RXBport on anRFU
DIN straightmaleconnector
l Feeder oftheantennasystem(noGATMconfigured)
l ANT porton theBias-Tee(GATMconfigured)
Cablesinstalledbeforedelivery
10.2 Inter-RFU RFSignalCable
QMA elbowmaleconnector
RX OUTAport on anRFU
QMA elbowmaleconnector
RX INB porton anotherRFU
2.1.2 BTS3900 (Ver.C) Cable ListThe BTS3900 cables include PGND cables, equipotential cable, power cables, transmissioncables, signal cables, CPRI electrical cables, and RF cables.
PGND Cables and Equipotential CableThe following table describes the PGND cables and equipotential cable.
Table 2-7 PGND cables and equipotential cableCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
PGND cablefor thecabinet
OT terminal Groundterminal onthe cabinet
OT terminal Externalground bar
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
12
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n Position5Equipotential Cables
OT terminal Wiringterminal fortheequipotential cable
OT terminal Wiringterminal fortheequipotentialcable
Cablesinstalledbeforedelivery
PGND cablefor a module
OT terminal Groundterminal on amodule
OT terminal Groundterminal forthe PGNDcable in thecabinet
Power CablesThe following table describes the power cables.
Table 2-8 Power cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
DCDU-11APowerCable
OT terminal l Blackwire:RTN(+)terminalon theDCDU
l Bluewire:NEG(-)terminalon theDCDU
Dependingon theexternalpowerequipment
Externalpowerequipment
ETP48150-A3 PowerCable
OT terminal Power inputterminal fortheETP48150-A3 subrack
Dependingon theexternalpowerequipment
Externalpowerequipment
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
13
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n Position6.4.4 RRUPowerCables
Tool-lessfemaleconnector(pressfittype)
One of theLOAD0 toLOAD5ports on theDCDU-11B
Dependingon the RRUmodel
Power porton an RRU
GATMPowerCable
3V3connector
-48V port onthe GATM
Tool-lessfemaleconnector(pressfittype)
LOAD8 orLOAD9 porton theDCDU-11A
DCDU-11BPowerCable
OT terminal l Blackwire:RTN(+)terminalon theDCDU-11B
l Bluewire:NEG(-)terminalon theDCDU-11B
Dependingon theexternalpowerequipment
Externalpowerequipment
Cablesinstalledbeforedelivery
6.4.3 RFUPowerCables
3V3connector
PWR port onthe RFU
Tool-lessfemaleconnector(pressfittype)
One of theLOAD0 toLOAD5ports on theDCDU-11A
FAN 03BPowerCable
3V3connector
-48V port onthe FAN 03B
Tool-lessfemaleconnector(pressfittype)
LOAD6 porton theDCDU-11A
6.4.2 BBUPowerCable
3V3connector
-48V port onthe UPEU
Tool-lessfemaleconnector(pressfittype)
LOAD7 orLOAD8 porton theDCDU-11A
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
14
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n PositionETP48150-A3 PowerCable(Black)
OT terminal RTN(+)terminal ontheDCDU-11A
OT terminal RTN(+)power outputterminal fortheETP48150-A3 subrack
ETP48150-A3 PowerCable(Blue)
OT terminal NEG(-)terminal ontheDCDU-11A
OT terminal NEG(-)power outputterminal fortheETP48150-A3 subrack
Transmission CablesThe following table describes the transmission cables.
Table 2-9 Transmission cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
7.1 E1/T1Cable
DB26 maleconnector
E1/T1 porton theGTMU,WMPT, orUTRP
Dependingon theexternalequipment
Externaltransmissionequipment
7.6 FE/GEEthernetCable
RJ45connector
FE0 port onthe GTMU,WMPT,LMPT, orUTRP
RJ45connector
Externaltransmissionequipment
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
15
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n Position7.3 FE/GEFiber OpticCable
LCconnector
SFP0 orSFP1 port onthe GTMU,WMPT,LMPT, orUTRP
l FCconnector
l SCconnector
l LCconnector
Externaltransmissionequipment
Cablesinstalledbeforedelivery
7.4Interconnection CableBetweenFE/GEElectricalPorts
RJ45connector
FE0 port onthe GTMU
RJ45connector
FE0 port onthe WMPT
7.5Interconnection CableBetweenFE/GEOpticalPorts
LCconnector
FE1 port onthe GTMU
LCconnector
FE1 port onthe WMPT
Signal CablesThe following table describes the signal cables.
Table 2-10 Signal cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
8.4.5 EMUMonitoringSignalCable
DB9 maleconnector
RS485 porton the EMU
RJ45connector
MON1 porton the UPEUor UEIU
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
16
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n Position8.2.19 BBUAlarmCable
RJ45connector
EXT-ALM0port on theUPEU orUEIU
RJ45connector
Externalalarm device
8.4.11 GPSClockSignalCable
SMA maleconnector
GPS port onthe USCU
Type Nfemaleconnector
GPS surgeprotector
RETControlSignalCable
SMA elbowmaleconnector
ANT0 toANT5 portson theGATM
SMA straightmaleconnector
DC/OOKport on theDIN Bias-Tee
GATMMonitoringSignalCable
RJ45connector
COM1 porton theGATM
RJ45connector
MON0 orMON1 porton the UPEU
FMUE-GATMMonitoringSignalCable
RJ45connector
COM2 porton theGATM
RJ45connector
COM IN porton the lower-level FAN03B
8.3.6MonitoringSignalCableBetweenCascadedFAN 03BUnits
RJ45connector
COM OUTport on theupper-levelFAN 03BNOTE
The upper-level FAN03Bcommunicates with theBBUdirectly.
RJ45connector
COM IN porton the lower-level FAN03BNOTE
The lower-level FAN03Bcommunicates with theBBUthrough theupper-levelFAN 03B.
8.4.15AdapterUsed forLocalMaintenance
USBconnector
USB(1) porton theUMPT in theBBU
Networkconnector
Networkcable
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
17
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n PositionCablesinstalledbeforedelivery
8.1.3 PMU01B-BBUMonitoringSignalCable
RJ45connector
COM_INport on theleft side ofthe PMU01B
RJ45connector
MON1 porton the UPEU
8.2.16FMUE-BBUMonitoringSignalCable
RJ45connector
COM IN porton the FAN03B
RJ45connector
MON0 porton the UPEUor UEIUNOTE
If no BBU isinstalled inthe cabinet,bind thecable on theright side ofthe cabinet.
8.4.2 ELUSignalCable
RJ45connector
ELU RJ45connector
SENSORport on theFAN 03B
NOTE
a: The security of the USB port is ensured by encryption, and the USB port can be shut down usingcommands. The USB commission port is used for commissioning the base station rather than configuringand exporting information of the base station.
CPRI Electrical CablesThe following table describes the CPRI electrical cables.
Table 2-11 CPRI electrical cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cablesinstalledbeforedelivery
9.1 CPRIElectricalCable
SFP20 maleconnector
CPRI port onthe GTMU,WBBP, orLBBP
SFP20 maleconnector
CPRI port onan RFU
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
18
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n PositionCables to beinstalledonsite
If boards and modules have been installed in a BTS3900 cabinet beforedelivery, CPRI electrical cables are also installed in the cabinet beforedelivery. In this case, only the CPRI electrical cables between BTS3900cabinets must be installed onsite.
RF CablesThe following table describes the RF cables.
Table 2-12 RF cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
10.1 RFJumpers
DIN elbowmaleconnector
ANT_TX/RXA orANT_RXBport on anRFU
DIN straightmaleconnector
l Feeder oftheantennasystem(noGATMconfigured)
l ANT porton theBias-Tee(GATMconfigured)
Cablesinstalledbeforedelivery
10.2 Inter-RFU RFSignalCable
QMA elbowmaleconnector
RX OUTAport on anRFU
QMA elbowmaleconnector
RX INB porton anotherRFU
2.1.3 BTS3900 (Ver.D) Cable ListThe BTS3900 cables include PGND cables, equipotential cable, power cables, transmissioncables, signal cables, CPRI electrical cables, and RF cables.
PGND Cables and Equipotential CableThe following table describes the PGND cables and equipotential cable.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
19
-
Table 2-13 PGND cables and equipotential cableCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
4 PGNDCablesFor thecabinet
OT terminal Groundterminal onthe cabinet
OT terminal Externalground bar
5Equipotential CablesBetween thecabinets
OT terminal Wiringterminal fortheequipotential cable
OT terminal Wiringterminal fortheequipotentialcable
Cablesinstalledbeforedelivery
4 PGNDCablesFor a module
OT terminal Groundterminal on amodule
OT terminal Groundterminal forthe PGNDcable in thecabinet
Power CablesThe following table describes the power cables for an AC-powered BTS3900.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
20
-
Table 2-14 Power cables for an AC-powered BTS3900Category Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
DCDU-12APowerCable
OT terminal l Blackwire:RTN(+)terminalon theDCDU-12A
l Bluewire:NEG(-)terminalon theDCDU-12A
OT terminal l Blackwire:RTN(+)terminalon theRFC2terminalfor theEPU05A-02subrack
l Bluewire:NEG(-)terminalon theRFC2terminalfor theEPU05A-02subrack
EPU05A-02PowerCable
OT terminal AC inputterminal fortheEPU05A-02subrack
Dependingon theexternalpowerequipment
Externalpowerequipment
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
21
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n PositionDCDU-12BPowerCable
OT terminal l Blackwire:RTN(+)terminalon theDCDU-12B
l Bluewire:NEG(-)terminalon theDCDU-12B
OT terminal l Blackwire:RTN(+)terminalon theRFC1 fortheEPU05A-02subrack
l Bluewire:NEG(-)terminalon theRFC1 fortheEPU05A-02subrack
GATMPowerCable
3V3connector
-48V port onthe GATM
Parallelterminal
LOAD8 orLOAD9 porton theDCDU-12A
6.4.4 RRUPowerCables
EPC5connector
One of theLOAD0 toLOAD5ports on theDCDU-12B
Dependingon the RRUmodel
Power porton an RRU
EPC4connector
One of theLOAD6 toLOAD8ports on theDCDU-12B
Dependingon the RRUmodel
Power porton an RRU
Cablesinstalledbeforedelivery
6.4.3 RFUPowerCables
3V3connector
PWR port onan RFU
EPC4connector
One of theLOAD0 toLOAD5ports on theDCDU-12A
FAN 03CPowerCable
3V3connector
-48V port onthe FAN 03C
EPC4connector
LOAD6 porton theDCDU-12A
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
22
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n Position6.4.2 BBUPowerCable
3V3connector
-48V port onthe UPEU
EPC4connector
LOAD7 orLOAD8 porton theDCDU-12A
The following table describes the power cables for a DC-powered BTS3900.
Table 2-15 Power cables for a DC-powered BTS3900Category Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
DCDU-12APowerCable
OT terminal l Blackwire:RTN(+)terminalon theDCDU-12A
l Bluewire:NEG(-)terminalon theDCDU-12A
Dependingon theexternalpowerequipment
Externalpowerequipment
6.4.4 RRUPowerCables
EPC5connector
One of theLOAD0 toLOAD5ports on theDCDU-12B
Dependingon the RRUmodel
Power porton an RRU
EPC4connector
One of theLOAD6 toLOAD8ports on theDCDU-12B
Dependingon the RRUmodel
Power porton an RRU
GATMPowerCable
3V3connector
-48V port onthe GATM
Parallelterminal
LOAD8 orLOAD9 porton theDCDU-12A
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
23
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n PositionDCDU-12BPowerCable
OT terminal l Blackwire:RTN(+)terminalon theDCDU-12B
l Bluewire:NEG(-)terminalon theDCDU-12B
Dependingon theexternalpowerequipment
Externalpowerequipment
Cablesinstalledbeforedelivery
4 PGNDCablesFor a module
OT terminal Groundterminal on amodule
OT terminal Groundterminal forthe PGNDcable in thecabinet
6.4.3 RFUPowerCables
3V3connector
PWR port onan RFU
EPC4connector
One of theLOAD0 toLOAD5ports on theDCDU-12A
FAN 03CPowerCable
3V3connector
-48V port onthe FAN 03C
EPC4connector
LOAD6 porton theDCDU-12A
6.4.2 BBUPowerCable
3V3connector
-48V port onthe UPEU
EPC4connector
LOAD7 orLOAD8 porton theDCDU-12A
Transmission CablesThe following table describes the transmission cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
24
-
Table 2-16 Transmission cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
7.1 E1/T1Cable
DB26 maleconnector
E1/T1 porton theGTMU,WMPT, orUTRP
Dependingon theexternalequipment
Externaltransmissionequipment
7.6 FE/GEEthernetCable
RJ45connector
FE0 port onthe GTMU,WMPT,LMPT, orUTRP
RJ45connector
Externaltransmissionequipment
7.3 FE/GEFiber OpticCable
LCconnector
SFP0 orSFP1 port onthe GTMU,WMPT,LMPT, orUTRP
l FCconnector
l SCconnector
l LCconnector
Externaltransmissionequipment
Cablesinstalledbeforedelivery
7.4Interconnection CableBetweenFE/GEElectricalPorts
RJ45connector
FE0 port onthe GTMU
RJ45connector
FE0 port onthe WMPT
7.5Interconnection CableBetweenFE/GEOpticalPorts
LCconnector
FE1 port onthe GTMU
LCconnector
FE1 port onthe WMPT
Signal CablesThe following table describes the signal cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
25
-
Table 2-17 Signal cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
8.4.5 EMUMonitoringSignalCable
DB9 maleconnector
RS485 porton the EMU
RJ45connector
MON1 porton the UPEUor UEIU
8.2.19 BBUAlarmCable
RJ45connector
EXT-ALM0port on theUPEU orUEIU
RJ45connector
Externalalarm device
8.4.11 GPSClockSignalCable
SMA maleconnector
GPS port onthe USCU
Type Nfemaleconnector
GPS surgeprotector
RETControlSignalCable
SMA elbowmaleconnector
ANT0 toANT5 portson theGATM
SMA straightmaleconnector
DC/OOKport on theDIN Bias-Tee
GATMMonitoringSignalCable
RJ45connector
COM1 porton theGATM
RJ45connector
MON0 orMON1 porton the UPEU
CMUEA-GATMMonitoringSignalCable
RJ45connector
COM2 porton theGATM
RJ45connector
COM IN porton the lower-level FAN03C
8.3.7MonitoringSignalCableBetweenCascadedFAN 03CUnits
RJ45connector
COM OUTport on theupper-levelFAN 03CNOTE
The upper-level FAN03Ccommunicates with theBBUdirectly.
RJ45connector
COM IN porton the lower-level FAN03CNOTE
The lower-level FAN03Ccommunicates with theBBUthrough theupper-levelFAN 03C.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
26
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n Position8.4.13 Inter-BBU SignalCables
DLCconnector
One of theM0 to M4ports on theUCIU in theBBU
DLCconnector
l CI port ontheUMPT inthe BBU
l S0 porton theUCIU inthe BBU
8.4.14 CableBetweenTwoCombinedBaseStations
DB15 maleconnector
GCK port onthe UCIU inthe BBU
MD36 maleconnector
CKB1 orCKB2 porton the DCTB
8.4.15AdapterUsed forLocalMaintenance
USBconnector
USB(1) porton theUMPT in theBBU
Networkconnector
Networkcable
Cablesinstalledbeforedelivery
8.1.4 PMU11A-BBUMonitoringSignalCable
RJ45connector
COM_INport on theleft side ofthe PMU11A
RJ45connector
MON1 porton the UPEU
8.2.17FMUEA-BBUMonitoringSignalCable
RJ45connector
COM IN porton the FAN03C
RJ45connector
MON0 porton the UPEUor UEIUNOTE
If no BBU isinstalled inthe cabinet,bind thecable on theright side ofthe cabinet.
8.4.2 ELUSignalCable
RJ45connector
ELU RJ45connector
SENSORport on theFAN 03C
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
27
-
NOTE
a: The security of the USB port is ensured by encryption, and the USB port can be shut down usingcommands. The USB commission port is used for commissioning the base station rather than configuringand exporting information of the base station.
CPRI Electrical CablesThe following table describes the CPRI electrical cables.
Table 2-18 CPRI electrical cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cablesinstalledbeforedelivery
9.1 CPRIElectricalCable
SFP20 maleconnector
CPRI port onthe GTMU,WBBP, orLBBP
SFP20 maleconnector
CPRI port onan RFU
Cables to beinstalledonsite
If boards and modules have been installed in a BTS3900 cabinet beforedelivery, CPRI electrical cables are also installed in the cabinet beforedelivery. In this case, only the CPRI electrical cables between BTS3900cabinets must be installed onsite.
RF CablesThe following table describes the RF cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
28
-
Table 2-19 RF cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
10.1 RFJumpers
DIN elbowmaleconnector
ANT_TX/RXA orANT_RXBport on anRFU
DIN straightmaleconnector
l Feeder oftheantennasystem(noGATMconfigured)
l ANT porton theBias-Tee(GATMconfigured)
Cablesinstalledbeforedelivery
10.2 Inter-RFU RFSignalCable
QMA elbowmaleconnector
RX OUTAport on anRFU
QMA elbowmaleconnector
RX INB porton anotherRFU
2.2 BTS3900L Cable ListThis section describes cable lists when the BTS3900L is configured with BTS3900L (Ver.B),BTS3900L (Ver.C), and BTS3900L (Ver.D) cabinets.
2.2.1 BTS3900L (Ver.B) Cable ListThe BTS3900L cables are the PGND cables, power cables, transmission cables, CPRI cables,signal cables, and RF cables.
PGND CablesThe following table describes the PGND cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
29
-
Table 2-20 PGND cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
PGND cablefor thecabinet
OT terminal(M8)
Groundterminal onthe cabinet
OT terminal(M8)
Externalground bar
Cablesinstalledbeforedelivery
PGND cablefor a module
OT terminal(M4)
Groundterminal on amodule
OT terminal(M4)
Groundterminal onthe cabinet
Power CablesThe following table describes the power cables.
Table 2-21 Power cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
DCDU-01PowerCable
OT terminal(M6)
l Blackwire:RTN(+)terminalon theDCDU-01
l Bluewire:NEG(-)terminalon theDCDU-01
Dependingon theexternalpowerequipment
Externalpowerequipment
6.4.4 RRUPowerCables(optional)
OT terminal(M4)
One of theLOAD0 toLOAD5ports on theDCDU-03B
Dependingon the RRUmodel
Power porton an RRU
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
30
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n Position6.4.8 GATMPowerCable
3V3connector
-48V port onthe GATM
Parallelterminal
SPARE1 orSPARE2port on theDCDU-01
DCDU-03BPowerCable(optional)
OT terminal(M6)
l Blackwire:RTN(+)terminalon theDCDU-03B
l Bluewire:NEG(-)terminalon theDCDU-03B
Dependingon theexternalpowerequipment
Externalpowerequipment
Cablesinstalledbeforedelivery
6.4.3 RFUPowerCables
3V3connector
PWR port onthe RFU
Parallelterminal
One of theRFU0 toRFU5 portson theDCDU-01
FAN PowerCables
3V3connector
-48V port onthe fanassembly
Parallelterminal
FAN port ontheDCDU-01
6.4.2 BBUPowerCable
3V3connector
PWR port onthe UPEU
Parallelterminal
BBU port ontheDCDU-01
Transmission CablesThe following table shows the transmission cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
31
-
Table 2-22 Transmission cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
7.1 E1/T1Cable
DB26 maleconnector
E1/T1 porton theGTMU,WMPT,UMPT, orUTRP
Dependingon theexternaltransmissionequipment
Externaltransmissionequipment
7.6 FE/GEEthernetCable
RJ45connector
FE or FE/GEelectricalport on theGTMU,WMPT,UMPT,LMPT, orUTRP
RJ45connector
Externaltransmissionequipment
7.3 FE/GEFiber OpticCable
LCconnector
l FE or FE/GEopticalport ontheGTMU,WMPT,UMPT,or UTRP
l SFP0 orSFP1port ontheLMPT
l FCconnector
l SCconnector
l LCconnector
Externaltransmissionequipment
Cablesinstalledbeforedelivery
7.4Interconnection CableBetweenFE/GEElectricalPorts
RJ45connector
FE electricalport on theGTMU,WMPT,UMPT, orLMPT
RJ45connector
FE0 port onthe WMPT
7.5Interconnection CableBetweenFE/GEOpticalPorts
LCconnector
FE opticalport on theGTMU,WMPT,UMPT, orLMPT
LCconnector
FE1 port onthe WMPT
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
32
-
Signal CablesThe following table describes signal cables.
Table 2-23 Signal cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
8.4.5 EMUMonitoringSignalCable
DB9 maleconnector
RS485 porton the EMU
RJ45connector
MON1 porton the UPEUor UEIU
8.2.19 BBUAlarmCable
RJ45connector
EXT-ALM0port on theUPEU orUEIU
RJ45connector
Externalalarm device
Inter-BBUSignalCables
DLCconnector
DLCconnector
CI port onthe UMPT
HEI port onthe WBBPf
HEI port onthe WBBPf
8.4.11 GPSClockSignalCable
SMA maleconnector
GPS port onthe USCU,LMPT, orUMPT
Type Nfemaleconnector
GPS surgeprotector
8.3.4MonitoringSignalCableBetweenCascadedFANs
RJ45connector
COM OUTport on theupper-levelfan assemblyNOTE
The upper-level fanassemblycommunicates with theBBUdirectly.
RJ45connector
COM IN porton the lower-level fanassemblyNOTE
The lower-level fanassemblycommunicates with theBBUthrough theupper-levelfanassembly.
RETControlSignalCable
SMA elbowmaleconnector
ANT0 toANT5 portson theGATM
SMA straightmaleconnector
DC/OOKport on theDIN Bias-Tee
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
33
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n Position8.4.16GATMMonitoringSignalCable
RJ45connector
COM1 porton theGATM
RJ45connector
MON1 porton the UPEUor MON0port on theUEIU
FMUC-GATMMonitoringSignalCable
RJ45connector
COM2 porton theGATM
RJ45connector
COM_INport on thelower-levelFAN
8.4.15AdapterUsed forLocalMaintenance
USBconnector
USB(1) porton theUMPT in theBBU
Networkconnector
Networkcable
8.4.14 CableBetweenTwoCombinedBaseStations
DB15 maleconnector
GCK port onthe UCIU inthe BBU
MD36 orDB15 maleconnector
DGLUb porton the DCTBin the 3012series basestation
Cablesinstalledbeforedelivery
8.2.15FMUC-BBUMonitoringSignalCable
RJ45connector
COM IN porton the FAN
RJ45connector
MON0 porton the UPEUor UEIU
8.4.2 ELUSignalCable
RJ45connector
ELU RJ45connector
SENSORport on theFAN
NOTE
a: The security of the USB port is ensured by encryption, and the USB port can be shut down usingcommands. The USB commission port is used for commissioning the base station rather than configuringand exporting information of the base station.
CPRI Electrical Cables and CPRI Fiber Optic CablesThe following table describes the CPRI electrical cables and CPRI fiber optic cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
34
-
Table 2-24 CPRI electrical cables and CPRI fiber optic cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cablesinstalledbeforedelivery
CPRIelectricalcables(1)
SFP20 maleconnector
CPRI portson theGTMU,WBBP,LBBP,UBRI, orUBBP
SFP20 maleconnector
CPRI0 orCPRI1 porton the RFU
Cables to beinstalled onsite
CPRI fiberoptic cable(optional)
DLCconnector
CPRI portson theGTMU,WBBP,LBBP,UBRI, orUBBP
DLCconnector
CPRI port onthe RRU
NOTE
(1) If boards and modules have been installed in a BTS3900L cabinet before delivery, CPRI electrical cablesare also installed in the cabinet before delivery. In this case, only the CPRI electrical cables between BTS3900cabinets must be installed onsite.
RF CablesThe following table describes the RF cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
35
-
Table 2-25 RF cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
10.1 RFJumpers
DIN elbowmaleconnector
ANT_TX/RXA orANT_RXBport on anRFU
DIN straightmaleconnector
l Feeder oftheantennasystem(noGATMconfigured)
l ANT porton theBias-Tee(GATMconfigured)
Cablesinstalledbeforedelivery
10.2 Inter-RFU RFSignalCable
QMA elbowmaleconnector
RX OUTport on theRFU
QMA elbowmaleconnector
RX IN porton anotherRFU
2.2.2 BTS3900L (Ver.C) Cable ListThe BTS3900L cables are the PGND cables, power cables, transmission cables, CPRI cables,signal cables, and RF cables.
PGND CablesThe following table describes the PGND cables.
Table 2-26 PGND cablesCategory Cable One End The Other End
Connector
InstallationPosition
Connector InstallationPosition
Cables to beinstalledonsite
PGND cablefor thecabinet
OTterminal(M8)
Groundterminal onthe cabinet
OT terminal(M8)
Externalground bar
Cablesinstalledbeforedelivery
PGND cablefor a module
OTterminal(M4)
Groundterminal on amodule
OT terminal(M4)
Groundterminal onthe cabinet
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
36
-
Power CablesThe following table describes the power cables.
Table 2-27 Power cablesCategory Cable One End The Other End
Connector
InstallationPosition
Connector InstallationPosition
Cables to beinstalledonsite
DCDU-11APowerCable
OTterminal
Global:l Black
wire:RTN(+)terminalon theDCDU-11A
l Bluewire:NEG(-)terminalon theDCDU-11A
UK:l Blue
wire:RTN(+)terminalon theDCDU-11A
l Graywire:NEG(-)terminalon theDCDU-11A
Dependingon theexternalpowerequipment
Externalpowerequipment
6.4.4 RRUPowerCables(optional)
Tool-lessfemaleconnector(pressfittype)
One of theLOAD0 toLOAD5ports on theDCDU-11B
Dependingon the RRUmodel
Power porton an RRU
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
37
-
Category Cable One End The Other EndConnector
InstallationPosition
Connector InstallationPosition
6.4.8 GATMPowerCable
3V3connector
-48V port onthe GATM
Parallelterminal
LOAD8 orLOAD9 porton theDCDU-11A
DCDU-11BPowerCable(optional)
OTterminal
Global:l Black
wire:RTN(+)terminalon theDCDU-11B
l Bluewire:NEG(-)terminalon theDCDU-11B
UK:l Blue
wire:RTN(+)terminalon theDCDU-11B
l Graywire:NEG(-)terminalon theDCDU-11B
Dependingon theexternalpowerequipment
Externalpowerequipment
Cablesinstalledbeforedelivery
6.4.3 RFUPowerCables
3V3connector
PWR port onthe RFU
Parallelterminal
One of theLOAD0 toLOAD5 portson theDCDU-11A
FAN 03BPowerCable
3V3connector
-48V port onthe FAN 03B
Parallelterminal
LOAD6 porton theDCDU-11A
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
38
-
Category Cable One End The Other EndConnector
InstallationPosition
Connector InstallationPosition
6.4.2 BBUPowerCable
3V3connector
-48V port onthe UPEU
Parallelterminal
LOAD7 orLOAD8 porton theDCDU-11A
Transmission CablesThe following table shows the transmission cables.
Table 2-28 Transmission cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
Cables to beinstalledonsite
7.1 E1/T1Cable
DB26 maleconnector
E1/T1 porton theGTMU,WMPT,UMPT, orUTRP
Dependingon theexternaltransmissionequipment
Externaltransmissionequipment
7.6 FE/GEEthernetCable
RJ45connector
FE or FE/GEelectricalport on theGTMU,WMPT,UMPT,LMPT, orUTRP
RJ45connector
Externaltransmissionequipment
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
39
-
Category Cable One End The Other EndConnector Installatio
n PositionConnector Installatio
n Position7.3 FE/GEFiber OpticCable
LCconnector
l FE or FE/GEopticalport ontheGTMU,WMPT,UMPT,or UTRP
l SFP0 orSFP1port ontheLMPT
l FCconnector
l SCconnector
l LCconnector
Externaltransmissionequipment
Cablesinstalledbeforedelivery
7.4Interconnection CableBetweenFE/GEElectricalPorts
RJ45connector
FE electricalport on theGTMU,WMPT,UMPT, orLMPT
RJ45connector
FE0 port onthe WMPT
7.5Interconnection CableBetweenFE/GEOpticalPorts
LCconnector
FE opticalport on theGTMU,WMPT,UMPT, orLMPT
LCconnector
FE1 port onthe WMPT
Signal CablesThe following table describes signal cables.
3900 Series Base StationCables 2 Cable List
Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.
40
-
Table 2-29 Signal cablesCategory Cable One End The Other End
Connector Installation Position
Connector Installation Position
top related