2x2 Bed Units & 7x1 Bed UnitsWilliams Corporation
22 Denver AvenueAuckland
- All work shall comply with the New Zealand Building Code and all relevant and associated standards, codes and territorial authority by-laws including terms and conditions of the building consent and any resource consents issued for project- Architectural drawings are to be read in conjunction with the structural engineers drawings and vice versa.- All proprietary items and materials shall be fixed, installed or applied in strict accordance with the manufacturers recommendations and specifications.- All documentation must be read in full and completely understood before any works begin and any discrepancies or ambuguity shall be clarified with design LBP before any work commences- The builder is responsible for the setting out of the works, the checking of all dimensions and levels on site, and the reporting of any discrepancies prior to commencement of work. Do not scale from these drawings.
Page Title
Project
Address
SheetRevision
Scale A1 page size (Half scale @ A3)
Issue Date
Time Stamp29/11/2019 1:45:13 pm
Denver Units
22 Denver Ave, Sunnyvale,Auckland
A1.0Cover Sheet
09/02/19
Sheet List
SheetNumber Sheet Name
CurrentRevision
A1.0 Cover Sheet
A1.1 Site Plan
A2.0 Unit 1 and 5 Floor Plans
A2.1 Unit 6 to Unit 9 Floor Plans
A3.0 Elevations Unit 1 to 5
A3.1 Elevations Unit 1 to 5
A3.2 Elevations Unit 6 to 9
A3.3 Elevations Unit 6 to 9
North Road View1
FD
WM
F
FDWM
F
FD
FD W
M
F
WM
F
Post
PostClo
the
s line
Wooden Retaining Wall
Wooden Fence
Wooden Fence
Wooden Fence
Wo
od
en
Fe
nce
Wooden Fence
Wooden Retaining Wall
Wo
od
en
Re
tain
ing
Wa
ll
DE
NV
ER
AV
EN
UE
14DP 9150122 Denver Avenue
15DP 9150120 Denver Avenue
17
47
810
Pt Lot 39DP 91501Road Reserve
Down Pipe
SWCPLL=60.46
SWCPLL=62.36ILout=61.44ILin=61.45
225mm
∅ Sto
rmw
ater
225mm∅ Stormwater
(Approximate location from Council Records)
Fire Hydrant
Power Plinth
Telecom Plinth
Water Meter
Valve
Street Light
Street Light
10
0m
m∅
Wate
r Main
(Ap
pro
ximate
loca
tion
from
Co
un
cil Re
cord
s)
13
.68
16
1°1
7'
15
.32
16
1°1
7'
11.75
53°49'
28.03
53°49'
26.58
71°18'
9.68
107°33'30"
7.6
01
43
°49
'
4.2
6
59.0
60.0
61
.0
61.061.0
61.0
62.062.0
62
.0
63.0
63.063.0
63
.0
64.0
58.2
58.4
58.6
58.8
59.259.4
59.6
59.8
60.2
60.460.4
60.4
60.660.6
60.6
60.860.8
60.8
60
.8
61.261.2
61
.2
61.461.4
61
.46
1.6
61
.6
61.6
61
.86
1.8
61.8
62
.26
2.2
62.2
62
.46
2.4
62.4
62.6
62
.66
2.6
62.6
62
.8
62.8
62.8
63
.26
3.2
63.2
63
.46
3.4
63.4
63
.66
3.6
63.6
63
.8
64.2
WM
F
WM
F
WM
F
WM
F
WM
F
NORTH
Unit 1
ExistingCrossing
Outdoor living space
27 m²Outdoor living space
21 m²
Outdoor living space
21 m²
Outdoor living space
21 m²Outdoor living space
30 m²
Outdoor living space
48 m²Outdoor living space
22 m² Outdoor living space
32 m²
Outdoor living space
42 m²
Unit 2
bedroom view 3x3m
livin
g v
iew
6x4m
bedroom view 3x3m
livin
g v
iew
6x4m
bedroom view 3x3m
livin
g v
iew
6x4m
bedroom view 3x3m
livin
g v
iew
6x4m
bedroom view 3x3m
livin
g v
iew
6x4m
bedroom view 3x3m
livin
g v
iew
6x4m
bedroom view 3x3m
livin
g v
iew
6x4m
bedroom view 3x3m
livin
g v
iew
6x4m
bedro
om
vie
w 3
x3m
living view 6x4m
Unit 3Unit 4Unit 5
Unit 9
Unit 8
Unit 7
Unit 6
Unit 1 Carpark
Unit 5 Carpark
16509
1200
346
7478
3462
20.3
6 m
FFL 62900
FFL 62900
FFL 63200
FFL 63200
Existing timber retainingwall to be replaced
Max 0.4m firth garden retaining wall (Ezi wall orsimilar)
Max 1.4m retaining walltop of wall 62650
479
1200
909
Top of retaining62.3
62730
6279762769
63050
63050
63000
62730
62792
1°
4°
4021
523
3000
3000
626
1200400
4632
5000
CC
62720
1782
frame
1842
fram
e
3496
fram
e
2074
frame1800
Existing timber retainingwall to be replaced
1000 ltrtanksalotround tankfor unit 61150 D x 1020 H
SCOPE OF WORKS:
COUNCIL:ZONE : Residential - Mixed Housing Urban ZoneHEIGHT (max. 8m) : COMPLIANTSETBACKS : Road BoundaryRECESSION PLANES : 3m + 45 degrees
ZONES NZS 3604:2011: (Taken from Branz Maps)Legal Description: Lot 14 DP 91501Address: 22 Denver Avenue SunnyvaleEarthquake Zone: Zone 1Corrosion Zone: Zone CClimate Zone: 1Wind Region: ALee Zone: Rainfall Intensity (range): 90-100Wind Zone (Experimental): Extra High
AREAS:ROOF AREA : 333m²PERGOLA AREA : (0.25x22) + (0.14x33) = 10.12m²GARDEN SHEDS : (11x(1.53x.79))= 13.29m²TOTAL BUILDING : 311m²TOTAL SITE FOR BLOCK : 809m²SITE COVERAGE : 38.4%
SET OUT NOTES:Contractor must independently verify all boundaries and dimensions prior to set out. All set out dimensions are in horizontal plane and do not take into account varying ground levels.
HAZARD:New construction area to be fully fenced before commencing construction. All work to comply with NZBC clause F5/AS1 part 1.
EROSION AND SEDIMENT CONTROL:All erosion and sediment control measures to be installed prior to commencement of earthworks to comply with Erosion and Sediment Control Guidelines for Small Sites. The contractor is responsible for checking that the sediment controls are properly maintained and correctly positioned. To be inspected each working day and maintained in good working order. Top soil stockpile should be close to works, limit amount of material supplied to only what is needed. Cover stock piles with waterproof covers. All stockpiles and site waste are to be stored so that the silt fence/ straw bales will control any run off from the site.Physically remove any sedimentation from the driveway and/or street. Do not wash into catchpits. If necessary use Filtrex Sock or similar around catch pits.Stabilise disturbed ground as soon as practical.The silt fence/ straw bales is to remain in place until site surface is grassed or stabilised.
All weather site access to consist of 150x200mm of crushed aggregate on geotextile filter cloth with 2m bund run off diversion @ site entry. All with cross scope to drain to sediment trap (where applicable).
Footpaths to comply with antislip requirements of NZBC D1/AS1 table 2
155.64 m²Lot 162.61 m²
Lot 262.63 m²
Lot 362.65 m²
Lot 491.22 m²
Lot 5
103.84 m²Lot 6 61.32 m²
Lot 7 76.81 m²Lot 8
108.99 m²Lot 9
24.66 m²Carpark Unit 5
- All work shall comply with the New Zealand Building Code and all relevant and associated standards, codes and territorial authority by-laws including terms and conditions of the building consent and any resource consents issued for project- Architectural drawings are to be read in conjunction with the structural engineers drawings and vice versa.- All proprietary items and materials shall be fixed, installed or applied in strict accordance with the manufacturers recommendations and specifications.- All documentation must be read in full and completely understood before any works begin and any discrepancies or ambuguity shall be clarified with design LBP before any work commences- The builder is responsible for the setting out of the works, the checking of all dimensions and levels on site, and the reporting of any discrepancies prior to commencement of work. Do not scale from these drawings.
Page Title
Project
Address
SheetRevision
Scale A1 page size (Half scale @ A3)
Issue Date
Time Stamp4/12/2019 10:26:42 am
Denver Units
22 Denver Ave, Sunnyvale,Auckland
A1.1Site Plan
08/28/19
1 : 100
Site plan1
Unit Area Schedules (Gross)
Level Name Area
Ground Floor Rear Unit 1 39 m²
Ground Floor Rear Unit 2 29 m²
Ground Floor Rear Unit 3 29 m²
Ground Floor Rear Unit 4 29 m²
Ground Floor Rear Unit 5 40 m²
Ground Floor Rear Unit 6 29 m²
Ground Floor Rear Unit 7 29 m²
Ground Floor Rear Unit 8 29 m²
Ground Floor Rear Unit 9 29 m²
Ground Floor Rear 282 m²
1st Floor Rear Unit 1 39 m²
1st Floor Rear Unit 2 29 m²
1st Floor Rear Unit 3 29 m²
1st Floor Rear Unit 4 29 m²
1st Floor Rear Unit 5 40 m²
1st Floor Rear Unit 6 29 m²
1st Floor Rear Unit 7 29 m²
1st Floor Rear Unit 8 29 m²
1st Floor Rear Unit 9 29 m²
1st Floor Rear 282 m²
Grand total 563 m²
Lot Schedule
Name Area
Lot 1 156 m²
Lot 2 63 m²
Lot 3 63 m²
Lot 4 63 m²
Lot 5 91 m²
Lot 6 104 m²
Lot 7 61 m²
Lot 8 77 m²
Lot 9 109 m²
Grand total 786 m²
Site Area key
Type Area
Concrete foot paths 99 m²
Drive way 37 m²
Landscape areas 105 m²
Outdoor living space 263 m²
Service space 36 m²
Grand total: 36 541 m²
Total (Roof Areas)
Name Area
Roof Area Units 1 to 5 194 m²
Roof Area Units 6 to 9 140 m²
Grand total 333 m²
1 : 200
Site areas2
Carpark Unit 1
S/A
FD
S/A
S/A F
D
S/A F
D S/A
FD
WM
F
S/A
FD
WM
F
S/A
S/A
FD
S/A
FD
S/A
FD
WM
F
WM
F
WM
F
FD
A3.0
2
A3.0
1
A3.11
A C D E
1
2
B
1
A4.0
2
A4.0
3
A4.0
F
Unit 1
Unit 2Unit 3Unit 4
Unit 5
Bedroom 2
Bedroom 1
Landing
Store
Bathroom
Bedroom1
w.r
Store
Landing
Bathroom
Bedroom1
w.r
Store
Landing
Bathroom
Landing
Bedroom1
w.r
Store
Bathroom Landing
Bedroom 1 Bedroom 2
w.r
w.r
Bathroom
Store
5465 5020 5020 5020 6945
90 90 90 3010 90 2140 90 90 90 1000 90 3660 90 90 90 1000 90 3660 90 90 90 1000 90 3660 90 90 90 1710 90 90 90 1020 70 580 70 3000 90
90 1470 70 1470 90 1040 90 1010 270 1000 0900 1200 90 2370 270 1000 0900 1200 90 2370 270 1000 0900 1200 90 2370 270 3000 70 580 70 1055 90 1855 90
1158 1830 1212 830 210 270 1970 1830 950 270 1970 1830 950 270 1970 1830 950 270 786 830 94 270 94 830 1353 1830 633
7000
270
6820
270
90
3050
70
580
70
3050
90
90
1955
90
1605
90
3080
90
694
1830
1774
1830
693
0164 1830 1206 830 1210 270 1346 830 1353 960 262 270 1345 830 1316 960 299 270 1345 830 1316 960 299
270
440 830 440
860
1830
1771
830
489
90
3010
90
2140
90
90
1470
70
1470
90
1040
090
01010
90
500
90
2140
90
3010
90
1080
90 3010 90 2140 90 90 90 2290 90 2370 90 90 90 2290 90 2370 90 90 90 2290 90 2370 90 90 90 1710 270 1050 90 1655 90 1855 90
-
---
580
1080
700
760
A3.0
2
A3.0
1
A3.11
A C D E
1
2
B
1
A4.0
2
A4.0
3
A4.0
F
270 5240 90 90 90 4750 90 90 90 4750 90 90 90 4750 90 90 90 1710 270 4740
5465 5020 5020 5020 6945
7000
270
6820
270
90
300
90
4220
90
2120
90
90
390
4310
1470
650
90
4297
1830
693
90 4140 90 1010
0900 1245 90 3905 90 0900 90 4501 70
179
90
90
90 4530 70 150
9090
90 4530 70 150
9090
90 1710 90 90 90 4530 306030
1000 90 3660 270 1000 90 3660 270 1000 90 3660 270 1710 90 3065 1645 90 120 90
0 1169 1816 2255 270 1983 1816 952 270 1982 1816 952 270 1982 1816 952 270 706 830 174 270 2289 1816 635
0167 970 2063 830 1210 90 90 90 1345 830 1311 970 294901800 1345 830 1311 970 564 1345 830 1311 970 294270 390 830 490 270 3470 970 120
270 5240 270 4750 270 4750 270 4750 270 1710 270 4560
Unit 1
Unit 2Unit 3Unit 4Unit 5
59
149
1830
90
3685
90
1645
90
1095
1020
1570
90
815
70
760
90
4140
90
1010
90
90
1190
90
4320
90
760
580
700
1080
-
---
- All work shall comply with the New Zealand Building Code and all relevant and associated standards, codes and territorial authority by-laws including terms and conditions of the building consent and any resource consents issued for project- Architectural drawings are to be read in conjunction with the structural engineers drawings and vice versa.- All proprietary items and materials shall be fixed, installed or applied in strict accordance with the manufacturers recommendations and specifications.- All documentation must be read in full and completely understood before any works begin and any discrepancies or ambuguity shall be clarified with design LBP before any work commences- The builder is responsible for the setting out of the works, the checking of all dimensions and levels on site, and the reporting of any discrepancies prior to commencement of work. Do not scale from these drawings.
Page Title
Project
Address
SheetRevision
Scale A1 page size (Half scale @ A3)
Issue Date
Time Stamp29/11/2019 1:45:16 pm
Denver Units
22 Denver Ave, Sunnyvale,Auckland
A2.0Unit 1 and 5 Floor Plans
11/07/19
Lower Area Schedule (Gross Building) Units ...
Area Name
39 m² Unit 1
29 m² Unit 2
29 m² Unit 3
29 m² Unit 4
40 m² Unit 5
166 m²
Upper Area Schedule (Gross Building)...
Area Name
39 m² Unit 1
29 m² Unit 2
29 m² Unit 3
29 m² Unit 4
40 m² Unit 5
166 m²
1 : 50
1st Floor Front1
1 : 50
Ground floor Front2
S/A
FD
WM
F
S/A
FD
WM
F
S/A
FD
S/A
FD
WM
F
WM
F
S/A
FD
S/A
FD
S/A
FD
S/A
FD
Living & Dining
Kitchen Kitchen
Kit
ch
en
Living & Dining
Kit
ch
en
Living & Dining
Entry Entry
Living & Dining
Store Store
Store Store
A3.2
1
A3.3 1
A3.2
2
A3.32
G H I J K
3
5
6525
1415
830
1597
1830
673
270 4020 270 4020 270 2240 270 3835 270 2240 270 3835 270
90 3010 90 920 90 90 90 920 90 3010 90 90 90570 90 1080 90 2295 1064 1156 90 90 90 570 90 1080 90 2295 1064 1156 90
1
A4.1
2
A4.1
3
A4.1
4245 4290 6615 6570
17201720
590 1816 1614 90180 1614 1816 590 90180 1336 830 74270 1339 1816 680 270 1336 830 74270 1332 1830 673
270
6345
270
90
5695
90
560
090
077970278827057083084027069
9702796270570830840270305
970570830134501801435830570970305
90 140 90 2780 90 920 90 90 90 920 90 2780 90 140
90 90
90 1740 90 2295 1064 1156 90 90 90 1741 90 2295 1064 1156
590
1816
1614
90
90
140
90
2780
90
920
90
90
90
90
4020
90
90
90
2325
270
4020
270
2505
4
Unit 9Unit 8
Unit 7Unit 6
Bedroom 1 Bedroom 1
Landing Landing
Storage Storage
Bathroom
w.r.
Storage Storage
Wardrobe Wardrobe
Landing Storage w.r.
w.r
. Bathroom
w.r
.
LandingSto
rag
e
Storage w.r.
Bathroom
w.r.
Bathroom
Bedroom 1
A3.0
1
A3.2
1
A3.3 1
A3.2
2
A3.32
G H I J K
3
5
6525
90
2365
90
600
90
3200
90
90
520
90
1755
90
600
90
381
90
1330
90
1309
90
1564
830
1597
1830
822
90 3010 90 920 270 920 90 3010 270 2365 90 600 90 3200 270 2365 90 600 90 3200 90
90 1920 90 4290 90 5716 90 1330 90 2219 90 2796 90 1330 90 1309 90
732 1830 1607 270 1607 1830 583 270 1336 830 1676 1830 673 270 1336 830 1676 1830 822
4245 4290 6615 6570
Stl
ora
ge
1
A4.1
2
A4.1
3
A4.1
90900900 1920 90 2010 0900900900 2010 90 1920 0900900900 640 90 1510 909090 1016 90 1330 90 1309 0900900900 640 90 1510 909090 1016 90 1330 90 1309 09009090
2505
583
1830
1607
090
03010
90
920
090
0
90
1920
90
2010
70
21
4
Unit 9Unit 8
Unit 7Unit 6
- All work shall comply with the New Zealand Building Code and all relevant and associated standards, codes and territorial authority by-laws including terms and conditions of the building consent and any resource consents issued for project- Architectural drawings are to be read in conjunction with the structural engineers drawings and vice versa.- All proprietary items and materials shall be fixed, installed or applied in strict accordance with the manufacturers recommendations and specifications.- All documentation must be read in full and completely understood before any works begin and any discrepancies or ambuguity shall be clarified with design LBP before any work commences- The builder is responsible for the setting out of the works, the checking of all dimensions and levels on site, and the reporting of any discrepancies prior to commencement of work. Do not scale from these drawings.
Page Title
Project
Address
SheetRevision
Scale A1 page size (Half scale @ A3)
Issue Date
Time Stamp29/11/2019 1:45:17 pm
Denver Units
22 Denver Ave, Sunnyvale,Auckland
A2.1Unit 6 to Unit 9 Floor Plans
08/29/19
1 : 50
Ground Floor Units 6 to 91
1 : 50
1st Floor Units 6 to 92
Lower Area Schedule (Gross Building) Units ...
Area Name
29 m² Unit 6
29 m² Unit 7
29 m² Unit 8
29 m² Unit 9
116 m²
Upper Area Schedule (Gross Building) Units ...
Area Name
29 m² Unit 6
29 m² Unit 7
29 m² Unit 8
29 m² Unit 9
116 m²
A C D EB30° 30°
20°
20°
30°30°
4.3.9.3.1
4.3.1.1.1
Ground floor Front62900
1st Floor Front65615
Roof Level Front68070
F
Ground Floor62900
95
AlternativeRecession PlaneNorth face(just cuts gutter)
45 deg @ 3mRecession PlaneSouth face
45 deg @ 3mRecession PlaneNorth face
AlternativeRecession PlaneSouth face
2588 1035
ACDE B
20°
30°30°
52°
30° 30°
4.3.1.1.1
Ground floor Front62900
1st Floor Front65615
Roof Level Front68070
F
AlternativeRecession PlaneNorth Face(Gutter cut)
45 deg @ 3mRecession PlaneNorth face
AlternativeRecession PlaneSouth Face
45 deg @ 3mRecession PlaneSouth face
1000 R
O*
1060
800 RO*860
W4W1
Viewed from outsideRO sizes take precedence over other sizesWet area glazing to be safety glass
W3
Match Front Door
990
1800 RO*
1860
S1 D1
1800 rough opening*
.
2100 r
ough o
penin
g*
.
970 rough opening*
.
2100 r
ough o
penin
g*
.
875panel
Viewed from outsideRO sizes take precedence over other sizesSlider to be safety glass
Pergola features Marcocarpa natural timberGalvanized steel bracketspainted black
Colour Schedule "The Coast"
BGC Weather board (Feature)"Resene Biscay"RGB 47 60 83, LRV 10
"Silver Pearl"Windows
"Gull Grey" RoofFasica & GutterDownpipes
"Resene Half Black White"SoffitsRGB 240 238 234 LVR 86
BGC Weather board"Resene Half Black White"RGB 237 237 229LRV 86
- All work shall comply with the New Zealand Building Code and all relevant and associated standards, codes and territorial authority by-laws including terms and conditions of the building consent and any resource consents issued for project- Architectural drawings are to be read in conjunction with the structural engineers drawings and vice versa.- All proprietary items and materials shall be fixed, installed or applied in strict accordance with the manufacturers recommendations and specifications.- All documentation must be read in full and completely understood before any works begin and any discrepancies or ambuguity shall be clarified with design LBP before any work commences- The builder is responsible for the setting out of the works, the checking of all dimensions and levels on site, and the reporting of any discrepancies prior to commencement of work. Do not scale from these drawings.
Page Title
Project
Address
SheetRevision
Scale A1 page size (Half scale @ A3)
Issue Date
Time Stamp29/11/2019 1:45:21 pm
Denver Units
22 Denver Ave, Sunnyvale,Auckland
A3.0Elevations Unit 1 to 5
08/29/19
1 : 50
Units 1 to 5 North Elevation1
1 : 50
Units 1 to 5 South Elevation2
Window Schedule Front Unit
Model Height WidthRough Opening
(Height)Rough Opening
(Width) Count
W1 1030 830 1000 800 27
W3 1030 1830 1000 1800 20
W4 1030 960 1000 930 3
Grand total: 50 50
Elevation Keynote Legend
Key Value Keynote Text
4.2.5.1.2 BGC fibre cement weather boards with paint finish on 20mmH3.1 timber cavity battens
4.3.1.1.1 .55mm Longrun corrugated roofing on Thermakraft selfsupporting roof underlay on 70 x 45 purlins @ 900 ctrs.
4.3.9.3.1 Coloursteel fascia and gutter. Refer to roof plan for Downpipepositions
4.5.2.1.1 Double glazed aluminium powdercoated window and doorjoinery
Door Schedule Front Units
Model Height WidthRoughHeight
RoughWidth Count
D1 2035 918 2100 970 9
S1 2100 1800 2113 1816 9
Grand total: 18 18
12
Ground floor Front62900
1st Floor Front65615
Roof Level Front68070
Ground Floor62900
30°
1 2
30°
4.3.1.1.1
2702
AlternativeRecession Plane Gutter breach only
Normal recession plane breach
7914
3663
30°30°
20°
20°
20°
20°
30°30°
20°
30°
30°
20°
1000 R
O*
1060
800 RO*860
W4W1
Viewed from outsideRO sizes take precedence over other sizesWet area glazing to be safety glass
W3
Match Front Door
990
1800 RO*
1860
S1 D1
1800 rough opening*
.
2100 r
ough o
penin
g*
.
970 rough opening*
.
2100 r
ough o
penin
g*
.
875panel
Viewed from outsideRO sizes take precedence over other sizesSlider to be safety glass
Pergola features Marcocarpa natural timberGalvanized steel bracketspainted black
Colour Schedule "The Coast"
BGC Weather board (Feature)"Resene Biscay"RGB 47 60 83, LRV 10
"Silver Pearl"Windows
"Gull Grey" RoofFasica & GutterDownpipes
"Resene Half Black White"SoffitsRGB 240 238 234 LVR 86
BGC Weather board"Resene Half Black White"RGB 237 237 229LRV 86
- All work shall comply with the New Zealand Building Code and all relevant and associated standards, codes and territorial authority by-laws including terms and conditions of the building consent and any resource consents issued for project- Architectural drawings are to be read in conjunction with the structural engineers drawings and vice versa.- All proprietary items and materials shall be fixed, installed or applied in strict accordance with the manufacturers recommendations and specifications.- All documentation must be read in full and completely understood before any works begin and any discrepancies or ambuguity shall be clarified with design LBP before any work commences- The builder is responsible for the setting out of the works, the checking of all dimensions and levels on site, and the reporting of any discrepancies prior to commencement of work. Do not scale from these drawings.
Page Title
Project
Address
SheetRevision
Scale A1 page size (Half scale @ A3)
Issue Date
Time Stamp29/11/2019 1:45:23 pm
Denver Units
22 Denver Ave, Sunnyvale,Auckland
A3.1Elevations Unit 1 to 5
11/14/19
1 : 50
Units 1 to 5 East Elevation1
1 : 50
Units 1 to 5 West Elevation2
1 : 50
Roof Level Units 1 to 53
Window Schedule Front Unit
Model Height WidthRough Opening
(Height)Rough Opening
(Width) Count
W1 1030 830 1000 800 27
W3 1030 1830 1000 1800 20
W4 1030 960 1000 930 3
Grand total: 50 50
Elevation Keynote Legend
Key Value Keynote Text
4.2.5.1.2 BGC fibre cement weather boards with paint finish on 20mmH3.1 timber cavity battens
4.3.1.1.1 .55mm Longrun corrugated roofing on Thermakraft selfsupporting roof underlay on 70 x 45 purlins @ 900 ctrs.
4.3.9.3.1 Coloursteel fascia and gutter. Refer to roof plan for Downpipepositions
4.5.2.1.1 Double glazed aluminium powdercoated window and doorjoinery
Door Schedule Front Units
Model Height WidthRoughHeight
RoughWidth Count
D1 2035 918 2100 970 9
S1 2100 1800 2113 1816 9
Grand total: 18 18
1000 R
O*
1060
800 RO*860
W4W1
Viewed from outsideRO sizes take precedence over other sizesWet area glazing to be safety glass
W3
Match Front Door
990
1800 RO*
1860
S1 D1
1800 rough opening*
.
2100 r
ough o
penin
g*
.
970 rough opening*
.
2100 r
ough o
penin
g*
.
875panel
Viewed from outsideRO sizes take precedence over other sizesSlider to be safety glass
Ground Floor Rear63200
1st Floor Rear65915
Roof Level Rear68370
GHIJK
4.2.5.1.2
4.5.2.1.1
AlternativeRecession PlanePart building only
45 deg @ 3mRecession PlaneNorth face
839
583
Ground Floor Rear63200
1st Floor Rear65915
Roof Level Rear68370
G H I J K
4.2.5.1.2
4.2.5.1.2
AlternativeRecession Plane
45 deg @ 3mRecession PlaneSouth face
45 deg @ 3mRecession PlaneNorth face
2700
20m limitline for Alturnativerecession
3076 3337
980
This breach is within AlternativeRecession Plane area
799
858
Pergola features Marcocarpa natural timberGalvanized steel bracketspainted black
Colour Schedule "The Coast"
BGC Weather board (Feature)"Resene Biscay"RGB 47 60 83, LRV 10
"Silver Pearl"Windows
"Gull Grey" RoofFasica & GutterDownpipes
"Resene Half Black White"SoffitsRGB 240 238 234 LVR 86
BGC Weather board"Resene Half Black White"RGB 237 237 229LRV 86
- All work shall comply with the New Zealand Building Code and all relevant and associated standards, codes and territorial authority by-laws including terms and conditions of the building consent and any resource consents issued for project- Architectural drawings are to be read in conjunction with the structural engineers drawings and vice versa.- All proprietary items and materials shall be fixed, installed or applied in strict accordance with the manufacturers recommendations and specifications.- All documentation must be read in full and completely understood before any works begin and any discrepancies or ambuguity shall be clarified with design LBP before any work commences- The builder is responsible for the setting out of the works, the checking of all dimensions and levels on site, and the reporting of any discrepancies prior to commencement of work. Do not scale from these drawings.
Page Title
Project
Address
SheetRevision
Scale A1 page size (Half scale @ A3)
Issue Date
Time Stamp29/11/2019 1:45:26 pm
Denver Units
22 Denver Ave, Sunnyvale,Auckland
A3.2Elevations Unit 6 to 9
11/14/19
Window Schedule Front Unit
Model Height WidthRough Opening
(Height)Rough Opening
(Width) Count
W1 1030 830 1000 800 27
W3 1030 1830 1000 1800 20
W4 1030 960 1000 930 3
Grand total: 50 50
Elevation Keynote Legend
Key Value Keynote Text
4.2.5.1.2 BGC fibre cement weather boards with paint finish on 20mmH3.1 timber cavity battens
4.3.1.1.1 .55mm Longrun corrugated roofing on Thermakraft selfsupporting roof underlay on 70 x 45 purlins @ 900 ctrs.
4.3.9.3.1 Coloursteel fascia and gutter. Refer to roof plan for Downpipepositions
4.5.2.1.1 Double glazed aluminium powdercoated window and doorjoinery
Door Schedule Front Units
Model Height WidthRoughHeight
RoughWidth Count
D1 2035 918 2100 970 9
S1 2100 1800 2113 1816 9
Grand total: 18 18
1 : 50
Units 6 to 9 North Elevation1
1 : 50
Units 6 to 9 South Elevation2
Ground Floor Rear63200
1st Floor Rear65915
Roof Level Rear68370
3 5
4.5.2.1.1
4.2.5.1.2
4.2.5.1.2
4
988
90120m limitline for Alturnativerecession
Alturnativerecession in back ground
Std recessionplane cut. Partexcluded by atlernativeHiRB
2313
563
3000
Length outside
1019
Ground Floor Rear63200
1st Floor Rear65915
Roof Level Rear68370
4.2.5.1.2
4.5.2.1.1
AlternativeRecession Plane
45 deg @ 3mRecession Plane
917
889
Gable shown is withinalternative recession planearea
20°
27°
27°
30°30°
27°
27°
30° 30°
30°30°
20°
20°
1000 R
O*
1060
800 RO*860
W4W1
Viewed from outsideRO sizes take precedence over other sizesWet area glazing to be safety glass
W3
Match Front Door
990
1800 RO*
1860
S1 D1
1800 rough opening*
.
2100 r
ough o
penin
g*
.
970 rough opening*
.
2100 r
ough o
penin
g*
.
875panel
Viewed from outsideRO sizes take precedence over other sizesSlider to be safety glass
Pergola features Marcocarpa natural timberGalvanized steel bracketspainted black
Colour Schedule "The Coast"
BGC Weather board (Feature)"Resene Biscay"RGB 47 60 83, LRV 10
"Silver Pearl"Windows
"Gull Grey" RoofFasica & GutterDownpipes
"Resene Half Black White"SoffitsRGB 240 238 234 LVR 86
BGC Weather board"Resene Half Black White"RGB 237 237 229LRV 86
- All work shall comply with the New Zealand Building Code and all relevant and associated standards, codes and territorial authority by-laws including terms and conditions of the building consent and any resource consents issued for project- Architectural drawings are to be read in conjunction with the structural engineers drawings and vice versa.- All proprietary items and materials shall be fixed, installed or applied in strict accordance with the manufacturers recommendations and specifications.- All documentation must be read in full and completely understood before any works begin and any discrepancies or ambuguity shall be clarified with design LBP before any work commences- The builder is responsible for the setting out of the works, the checking of all dimensions and levels on site, and the reporting of any discrepancies prior to commencement of work. Do not scale from these drawings.
Page Title
Project
Address
SheetRevision
Scale A1 page size (Half scale @ A3)
Issue Date
Time Stamp29/11/2019 1:45:29 pm
Denver Units
22 Denver Ave, Sunnyvale,Auckland
A3.3Elevations Unit 6 to 9
11/14/19
1 : 50
Units 6 to 9 East Elevation1
1 : 50
Roof Level Units 6 to 93
Window Schedule Front Unit
Model Height WidthRough Opening
(Height)Rough Opening
(Width) Count
W1 1030 830 1000 800 27
W3 1030 1830 1000 1800 20
W4 1030 960 1000 930 3
Grand total: 50 50
Elevation Keynote Legend
Key Value Keynote Text
4.2.5.1.2 BGC fibre cement weather boards with paint finish on 20mmH3.1 timber cavity battens
4.3.1.1.1 .55mm Longrun corrugated roofing on Thermakraft selfsupporting roof underlay on 70 x 45 purlins @ 900 ctrs.
4.3.9.3.1 Coloursteel fascia and gutter. Refer to roof plan for Downpipepositions
4.5.2.1.1 Double glazed aluminium powdercoated window and doorjoinery
Door Schedule Front Units
Model Height WidthRoughHeight
RoughWidth Count
D1 2035 918 2100 970 9
S1 2100 1800 2113 1816 9
Grand total: 18 18