2010 catalogue
Post on 19-Mar-2016
227 Views
Preview:
DESCRIPTION
TRANSCRIPT
09/10
general catalogue
Openers & Closers was founded in Barcelona in 1989, with the aim of manufacturing quality door locks and ensuring an efficient customer service.
After 20 years of experience, O&C is one of the leading European manufactu-rers of electric strikes and electromagnetic locks, exporting approximately 90% of production in over 40 different countries.
Such achievement is probably the result of the company’s policy of constantly improving product quality while maintaining an affordable price, in combi-nation with the staff engagement to educate, update and advise clients on a regular basis.
O&C currently owns over 30 patents for technical and production innovations, entirely designed and manufactured in Spain. All our products have been tes-ted by APPLUS+ Norcontrol and LGAI Technological Center.
Nevertheless, higher quality means lower energy consumption and less waste generation thanks to longer product life. As a matter of fact, our products are guaranteed from 3 to 5 years. Our commitment to the environment is also wit-nessed by our respect of the RoHS.
OPENERS & CLOSERS: INNOVATION, QUALITY & SERVICE.
electric strikes
asymmetrical electric strikessymmetrical electric strikes
security electric strikes
security electric strikes with electronic coil
electric strikes for panic devices
16,5 mm symmetrical mini electric strikes
IP54 waterproof electric strikes
security electric strikes for armoured doors
steel electric strikes for RF-120 doors
symmetrical steel electric strikes
new
new
22
asymmetrical electric strikes
Dimensions
Operation
Coil features
Technical features
Adjustable latch
symmetrical reversibility with DIN Right and Left
Fail-secure Hold-open Internal Hold-openwith mechanicalunlatching
with mechanicalunlatching
with mechanicalunlatching
asymmetrical reversibilitywith DIN Left
Hold-open
opened closed opened closed
Internal Hold-open
References and features
Fixed latch
Fixed latch
Fail-secure
Fail-secure with mechanical unlatching
Hold-open
Hold-open with mechanical unlatching
Internal Hold-open
Internal Hold-open with mechanical unlatching
The electric strike is locked when unenergized.
It works just like the Fail-secure model but with mechanical release function.
The electric strike has a device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.
It works just like the Hold-open model but with mechanical release function.
The electric strike has an internal device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.
It works just like the Internal Hold-open but with mechanical release function.
Adjustablelatch Preload Voltage References
DIN rightadd faceplate
ReferencesDIN leftadd faceplate
8-14 V ac/dc
8-14 V ac/dc
8-14 V ac/dc
8-14 V ac/dc
8-14 V ac/dc
8-14 V ac/dc
8-14 V ac/dc
8-14 V ac/dc
9-14 V ac/dc
9-14 V ac/dc
9-14 V ac/dc
9-14 V ac/dc
5-12 V ac/dc
5-12 V ac/dc
5-12 V ac/dc
5-12 V ac/dc
5-12 V ac/dc
5-12 V ac/dc
6-12 V ac/dc
6-12 V ac/dc
5-12 V ac/dc
5-12 V ac/dc
6-12 V ac/dc
6-12 V ac/dc
12 V dc
12 V dc
12 V dc
12 V dc
24 V dc
24 V dc
24 V dc
24 V dc
10.0.00.B
11.0.00.B
20.0.00.B
21.0.00.B
10.0.00.J
11.0.00.J
20.0.00.J
21.0.00.J
10.0.00.E
11.0.00.E
20.0.00.E
21.0.00.E
10.0.00.F
11.0.00.F
20.0.00.F
21.0.00.F
10.1.00.B
11.1.00.B
12.0.00.B
13.0.00.B
20.1.00.B
21.1.00.B
22.0.00.B
23.0.00.B
10.1.00.J
11.1.00.J
12.0.00.J
13.0.00.J
12A.0.00.J
13A.0.00.J
12A.0.00.B
13A.0.00.B
20.1.00.J
21.1.00.J
22.0.00.J
23.0.00.J
22A.0.00.B
23A.0.00.B
22A.0.00.J
23A.0.00.J
10.1.00.E
11.1.00.E
12.1.00.B
13.1.00.B
12A.1.00.B
13A.1.00.B
20.1.00.E
21.1.00.E
22.1.00.B
23.1.00.B
22A.1.00.B
23A.1.00.B
10.1.00.F
11.1.00.F
12.1.00.J
13.1.00.J
12A.1.00.J
13A.1.00.J
20.1.00.F
21.1.00.F
22.1.00.J
23.1.00.J
22A.1.00.J
23A.1.00.J
105
°C
Minutes 5(a 12 Vac)
(12 Ω 0,7 A a 12 Vac) 8/14 V ac/dcB
65
°C
Minutes 5(a 9 Vac)
(8 Ω 0,6 A a 9 Vac) 5/12 V ac/dcJ
53
°C
Hours 5
(60 Ω 0,20 A) 12 Vdc 100%E
77
°C
Hours 5
(220 Ω 0,12 A) 24 Vdc 100%F
Warning:
When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.
Incorrect installation could cause door-release failure.
Temperature test:
Measured on coil surface, tolerance ±10%
Other coils and voltages on demand
Electric strikes with «ac» coils work properly even with a pressure up to 16Kg
300.000 guaranteed openings
Withstands impacts up to 300 Kg
Steel screws
Low power consumption
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).
90
28
33,5
46,821
9,7
11
52,3
3
25
159
3
52
44
48,5
47,2
563,2
5
GREY
INOX 3mm GREY GREY
01
61 80 81
32,7
548,5
22,7
5 104
3
52
44
48,5
36
104,5
23
47,5
52
25,5
Reversible
Right
Right
Left
Left
DIN
DIN
Reversible Reversible
GREY/BROWN
INOX 3mm
03 05 04
63 65 64
D5 D4
D65 D64
C5 C4
C65 C64
D3
D63
C3
C63
Reversible Reversible
25
61,7
548,5
139,7
5
12
79
35
44
250
3
52
25
61,7
548,5
139,7
5
102
12,544
250
12
3
52
25
61,7
548,5
139,7
5 17
44
12,5
102
250
3
52
Adjustable latch (3mm)
3,2
5
Deep latch installation example Ref. 3
Fixed latch Ref. 012,7
8,2543,6
46,5
16
Standard adjustable latch Ref. 146,2
43,2
16,5
7,75
12,7
Shallow adjustable latch Ref. 2Supplied on demand
46,2
43,2
16,5
6,15
12,7
Deep adjustable latch Ref. 3Supplied on demand
46,2
43,2
16,5
13,3
12,7
90,4
21,3
52
9,4
33,47 ESP2
34
64
48
128
14
90
124
4
240
2
52
INOX 3mm
INOX 3mm
73
20
74
21
2
250
48
80
122
25
44
36
80
14
52
faceplates for asymmetrical electric strikes
4
faceplates for asymmetrical electric strikes
Door Handedness
DIN definition:The door is viewed from the side on which the hinges are visible.
DIN Left DIN Right DIN Left DIN Right
14552
36,5
25
106,9
GREY
CHROME
BRASS
84
84
84
Reversible
Reversible Reversible
BROWN BROWN
16 17
52
12
R10 R
10
R10
R10
44
52
R10 R
10
R10
R10
Right LeftDIN
79
250
250
2
32
25
35
250
2
25 32
44
35
79
12
Right LeftDIN
BROWN10 11 BROWN14 15
R10
R10
R 10 R 10
52
12
R10 R
10
R 10R 10
52
12
Right LeftDIN
BROWN12 13
12
102
44
250
32 25
2
250
44
12
102
48,5
2
32
25
Right LeftDIN
BROWN08 09
R10
R 10R 10
R10
52
48,5
25
32
44
172
5
symmetrical electric strikesReferences and features
Reversible
Fail-secure
Fail-Secure with mechanical unlatching
Hold-open
Hold-open with mechanical unlatching
Internal Hold-open
Internal Hold-open with mechanical unlatching
The electric strike is locked when unenergized.
It works just like the Fail-secure model but with mechanical release function.
The electric strike has a device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.
It works just like the Hold-open model but with mechanical release function.
The electric strike has an internal device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.
It works just like the Internal Hold-open but with mechanical release function.
Adjustablelatch Preload Electronic
protection Voltage Referenceslatch (1)add faceplate
8-14 V ac/dc
8-14 V ac/dc
8-14 V ac/dc
8-14 V ac/dc
9-14 V ac/dc
9-14 V ac/dc
5-12 V ac/dc
5-12 V ac/dc
5-12 V ac/dc
5-12 V ac/dc
6-12 V ac/dc
6-12 V ac/dc
12 V dc
12 V dc
24 V dc
24 V dc
30.1.00.B
31.1.00.B
32.1.00.B
30.1.00.J
31.1.00.J
32.1.00.J
30.1.00.E
31.1.00.E
30.1.00.F
31.1.00.F
33.1.00.B
33.1.00.J
32A.1.00.B
33A.1.00.B
32A.1.00.J
33A.1.00.J
Coil features
Operation Dimensions
Fail-secure Fail-secure Hold-open
Opened Closed
Hold-open Internal Hold-open Internal Hold-open Fail-safe
Technical features
105
°C
Minutes 5(a 12 Vac)
(14 Ω 0,7 A a 12 Vac) 8/14 V ac/dcB
65
°C
Minutes 5(a 9 Vac)
(8 Ω 0,6 A a 9 Vac) 5/12 V ac/dcJ
Electric strikes with «ac» coils work properly even with a pressure up to 16Kg.
300.000 guaranteed openings
Withstands impacts up to 280 Kg.
Steel screws
Low power consumption
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).
21
69
12
12
29
52
10
11
Warning:
When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.
Incorrect installation could cause door-release failure.
Temperature test:
Measured on coil surface, tolerance ±10%
Internal hold-open
53
°C
Hours 5
(50 Ω 0,25 A) 12 Vdc 100%E
77
°C
Hours 5
(185 Ω 0,12 A) 24 Vdc 100%F
Other coils and voltages on demand
Fail-safeThe electric strike is locked when energized.
12 V dc
24 V dc
34.1.00.E
34.1.00.F
with mechanicalunlatching
with mechanicalunlatching
with mechanicalunlatching
6
25
30,7
548,5
30,7
5
44
110
3
52
GREY
INOX 3mm
02
62
Reversible
52
25
61,7
548,5
139,7
5 17
44
12,5
102
250
3
52
25
61,7
548,5
139,7
5
102
12,544
250
12
3
INOX 3mm
D5
D65
C5
C65
04
64
D4
D64 C64
GREY/BROWNC405
65
Reversible
Right LeftDIN
INOX 3mm73 74
52
34
64
48
128
14
90
124
4
240
2
INOX 3mm20 21
2
250
48
80
122
25
44
36
80
14
Right LeftDIN
52
Adjustable latch (3mm)
Deep latch installation example Ref. 3
Standard adjustable latch Ref. 1
Deep adjustable latch Ref. 3Supplied on demand
ESP3
21,369,3
52
12
12
5,5
3
44,7
11,6
14,7
47,1
44,7
11,6
14,7
47,1
5,4
13,5
faceplatesfor symmetrical electric strikes
7
faceplatesfor symmetrical electric strikes
14552
36,5
25
106,9
GREY
CHROME
BRASS
84
84
84
Reversible12
102
44
250
32 25
2
250
44
12
102
48,5
2
32
25
R10
R10
R 10 R 10
52
12
R10 R
10
R 10R 10
52
12
Right RightLeft LeftDIN DIN
BROWN BROWN08 1209 13
Door Handedness
DIN definition:The door is viewed from the side on which the hinges are visible.
DIN Left DIN Right DIN Left DIN Right
Reversible ReversibleBROWN BROWN16 17
R10
R 10R 10
R10
52
48,5
25
32
44
172
8
security electric strikes
Coil features
Technical featuresReinforced mechanism box
Stainless steel lock cover
Steel latch and screws
Electric strikes with 12V ac coils are released by applying a pressure up to 16 kgWithstands impacts and pressures up to 500 Kg, getting destroyed at 700kg.
300.000 guaranteed openings Low power consumption
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).Latch adjustment regulator (is supplied on demand)
°C
Minutes 5(a 12 Vac)
(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL
6266
°C
Hours 5
(70 Ω 0,17A) 12 Vdc 100%M
°C
Hours 5
(240 Ω 0,10A) 24 Vdc 100%N
57
°C
Hours 5
(54 Ω 0,22 A) 2 microswitch 12 Vdc 100%P
Warning:
When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.
Incorrect installation could cause door-release failure.
Temperature test:
Measured on coil surface, tolerance ±10%
62
5156
FAIL-SAFE
FAIL-SECURE
References and featuresFixed latch
Fail-secure
Fail-secure with 1 microswitch
Fail-secure with 2 microswitch
Internal Hold-open
Fail-safe
Fail-safe with 1 microswitch
Fail-safe with 2 microswitch
The electric strike is locked when unenergized.
It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.
It works just like the Fail-secure model plus 2 electrical switching device that detects the status of the electric strike and the door.
The electric strike has an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.
The electric strike is locked when energized.
It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.
It works just like the Fail-safe model plus 2 electrical switching device that detects the status of the electric strike and the door.
Electronic protectionPreload Voltage
ReferencesDIN leftadd faceplate
ReferencesDIN rightadd faceplate
8-14 V ac/dc
8-14 V ac/dc
9-14 V ac/dc
12 V dc
12 V dc
12 V dc
12 V dc
24 V dc
24 V dc
12 V dc
12 V dc
24 V dc
24 V dc
24 V dc
24 V dc
4L0.4.00.L
4L6.4.00.L
4L6.4.00.M
4L4.4.00.M
4L6.4.00.N
4L4.4.00.N
4R0.4.00.L
4R6.4.00.L
4R6.4.00.M
4R4.4.00.M
4R6.4.00.N
4R4.4.00.N
47.4.00.P
47.4.00.N
4L0.4.00.M4R0.4.00.M
4L0.4.00.N4R0.4.00.N
4L8.4.00.M4R8.4.00.M
4L8.4.00.N4R8.4.00.N
49.4.00.P
49.4.00.N
4L2A.4.00.L4R2A.4.00.L
Fail-secure Internal Hold-open OperationFail-safe 1 microswitch 2 microswitch
D D D D DI I I I I opened closedasymmetrical reversibility
Interconnection between principal and secondary microswitch
Schematic electric diagram
Push button Push button
Light Light
Secondarymicroswitch
S2
Principal microswitch S1
Principal microswitch S1
Power supply Power supply
Door openedDoor opened
Unlocked lever(electric strike open)
Door closedDoor closed
Common
Connection
Door released and lever unlocked
Door closed and lever lockedDoor released
Electric connection
Unlocked lever connection
Locked lever connectionCommon
Electric connection
Door closed connection
Door released connectionPrincipal microswitch S1
Secondary microswitch S2
Common
Principal microswitch S1 Secondary microswitch S2
Intensity 1A/125 Vac0,5A/30 Vdc
0,5A/30 Vdc
Operating speed 1 at 500 mm/second (at pin plunger) 1 at 500 mm/second (at pin plunger)
Operating frecuency Mechanical: 200 operations per minute Electrical: 30 operations per minute
Mecánica: 200 operations per minute Eléctrica: 30 operations per minute
Contact resistance Standard type: 30 mΩ max. Standard type: 30 mΩ max.
Ambient temperature From -25°C a 65°C (without ice) From -25°C a 70°C (without ice)
Humidity 85% RH max. (5° a 35°C) 85% RH max. (5° a 35°C)
Life expectancy Mechanical: 300.000 operations min.Electrical: 30.000 operations min.
Mechanical: 30.000 operations min.Electrical: 30.000 operations min.
Fail-secure Fail-safe Fail-secure Fail-safe
Fail-secure Fail-safe
openedclosed
Other coils and voltages on demand
FAIL-SAFE
FAIL-SECURE
9
security electric strikeswith vibrating ac/dc electronic coil
References and features
Door access control with two ac/dc power supplies
Applications
Dimensions
Digital installations of telephone and video intercoms are generally equipped with batteries to supply the system in cases of power cuts.
When an access control system is working on:
«ac» current: the electric strike opens with a pressure of up to 16 kg on the latch and the coil emits the standard «ac» buzzing sound.«dc» current (from the batteries): the electric strike does not open under pressure and emits no sound. important notice: «dc» current does not admit pressure during electromagnetic release.
Security electric strikes with vibrating ac/dc electronic coil are suitable for all digital telephone and video intercom installations.
The electronic coil is activated whether it is working in «ac/dc» current, the standard buzzing signal is always emitted and the door release will open at any time under a pressure up to 14 kg.
Important notice: It should be noted that the electrical connections of the electronic coil are not polarized, so it should be connected in the same way as a fail secure electric strike.
It is recommended to install this kind of electric strike for all digital access control installations.
These top quality electric strikes, specially designed for security professionals, withstand pressures of up to 700 kg.
Technical featuresReinforced mechanism box
Stainless steel lock cover
Steel latch and screws
Electric strikes with electronic coils are released by applying a pressure up to 14kgWithstands impacts and pressures up to 500 Kg, getting destroyed at 700 Kg
300.000 guaranteed openings. Low power consumption
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014)
Fail-secure
Internal Hold-open
The electric strike is locked when unenergized.
The electric strike has an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.
Fixed latch Preload
Voltageac/dcintermittent
12 V ac/dc
12 V ac/dc
24 V ac/dc
24 V ac/dc
4R0.4.00.X 4L0.4.00.X
4R2A.4.00.X 4L2A.4.00.X
4R2A.4.00.Z 4L2A.4.00.Z
4R0.4.00.Z 4L0.4.00.Z
ReferencesDIN leftadd faceplate
ReferencesDIN rightadd faceplate
52
9,2
11
106,4
29,5
20,5
3,5
45 107
Door Handedness
DIN definition:The door is viewed from the side on which the hinges are visible.
DIN Left DIN Right DIN Left DIN Right
10
faceplates for security electric strikes
Reversible
Reversible Reversible
Reversible
159
253
52
44
65,5
49,5
Reversible Reversible
BROWN BROWN
16 17
172
48,5
2532
52
2 R10
R10
R 10R
10
44
Right RightLeft LeftDIN DIN
BROWN BROWN44 4547 48
225
32
250
48,5
44
12
70
61,7
5139,7
5
250
48,5
25
322
70
12
44
61,7
5139,7
5
52
R10
R10
R 10R 10
52
R10 R
10
R 10R 10
INOX 3mm
61
250
253
52
64
44
142
70
44
12
INOX 3mm
43
INOX 3mm
66
INOX 3mm
67
280
253
96
44
52
42
140
70
13
200
52
253
44
65,5
90,5
11
electric strikes for panic devicesReferences and features
Symmetrical reversibility
Fail-secure
Fail-secure with 1 microswitch
Fail-secure with 2 microswitch
Internal Hold-open
Fail-safe
Fail-safe with 1 microswitch
Fail-safe with 2 microswitch
The electric strike is locked when unenergized.
It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.
It works just like the Fail-secure model plus 2 electrical switching device that detects the status of the electric strike and the door.
The electric strike has an internal device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.
The electric strike is locked when energized.
It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.
It works just like the Fail-safe model plus 2 electrical switching device that detects the status of the electric strike and the door.
Preload Electronic protection
Fixed latch Voltage References
add box
8-14 V ac/dc
8-14 V ac/dc
9-14 V ac/dc
12 V dc
12 V dc
12 V dc
12 V dc
24 V dc
24 V dc
12 V dc
12 V dc
24 V dc
24 V dc
24 V dc
24 V dc
40.6.00.L
46.6.00.L
46.6.00.M
44.6.00.M
46.6.00.N
44.6.00.N
47.6.00.P
47.6.00.N
40.6.00.M
40.6.00.N
48.6.00.M
48.6.00.N
49.6.00.P
49.6.00.N
42A.6.00.L
Coil features
Technical features
°C
Minutes 5(a 12 Vac)
(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL
6266
°C
Hours 5
(70 Ω 0,17A) 12 Vdc 100%M
°C
Hours 5
(240 Ω 0,10A) 24 Vdc 100%N
57
°C
Hours 5
(54 Ω 0,22 A) 2 microswitch 12 Vdc 100%P
Warning:
When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.
Incorrect installation could cause door-release failure.
Temperature test:
Measured on coil surface, tolerance ±10%
Reinforced mechanism box
Stainless steel lock cover
Steel latch and screws
Electric strikes with 12V ac coils are released by applying a pressure up to 16 kgWithstands impacts and pressures up to 500 Kg, getting destroyed at 700kg.
300.000 guaranteed openings. Low power consumption
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).Latch adjustment regulator (is supplied on demand)
62
5156
BLACK BLACK BLACK
RED RED RED
82 83 85
82 83 85
Operation
Fail-secure Fail-safe
opened openedclosed closed
Internal Hold-openFail-secure Fail-safe Fail-secure Fail-secureFail-safe Fail-safe
1 microswitch 2 microswitch
Schematic electric diagram
Push button Push button
Light
Secondary microswitch
S2
Principal microswitch S1
Power supply
Door opened
Unlocked lever (electric strike open)
Door closed
Light
Principal microswitchS1
Power supply
Door openedDoor closed
Interconnection between principal and secondary microswitch
Common
Connection
Door released and lever unlocked
Door closed and lever lockedDoor released
Electric connection
Unlocked lever connection
Locked lever connectionCommon
Electric connection
Door closed connection
Door released connectionPrincipal microswitch S1
Secondary microswitch S2
Common
Principal microswitch S1 Secondary microswitch S2
Intensity 1A/125 Vac0,5A/30 Vdc
0,5A/30 Vdc
Operating speed 1 at 500 mm/second (at pin plunger) 1 at 500 mm/second (at pin plunger)
Operating frecuency Mechanical: 200 operations per minute Electrical: 30 operations per minute
Mechanical: 200 operations per minute Electrical: 30 operations per minute
Contact resistance Standard type: 30 mΩ max. Standard type: 30 mΩ max.
Ambient temperature From -25°C a 65°C (without ice) From -25°C a 70°C (without ice)
Humidity 85% RH max. (5° a 35°C) 85% RH max. (5° a 35°C)
Life expectancy Mechanical: 300.000 operations min.Electrical: 30.000 operations min.
Mechanical: 30.000 operations min.Electrical: 30.000 operations min.
Other coils and voltages on demand
FAIL-SAFEFAIL-SAFE
FAIL-SECUREFAIL-SECURE
12
surface boxes electric strikes for panic devices
Deep surface box
Installation instructions:
Standard surface box
Installation instructions:
Shielded surface box
1- Unscrew the 2 screws that attach the electric strike mechanism to the box 82 and remove the electric strike.
2- Make the electrical connection of the electric strike.3- Place the electric strike back in the box 82 with the 2 screws holding it.4- Place the electric strike between 12-14 mm. from the panic device, the latch must be
aligned. Set the box 82 on the frame with 4 screws.5- Press the black nylon trim on top of the box 82 in order to hide the 4 holding points.
1- Unscrew the 2 screws that attach the electric strike mechanism to the box 83 and remove the electric strike.
2- Locate the C-83 accessories under the box 83 until the lach gets aligned. 3- Pass the electric cable through the holes of the C-83 accessories4- Place the C-83 accessories on the door at 12-14 mm. from the panic device.Hold
them with the screws.5- Make the electrical connection of the electric strike.6- Place the electric strike back in the box 83 with the 2 screws holding it.7- Set the box 83 on the C-83 accessories with 4 screws.8- Press the black nylon trim on top of the box 83 in order to hide the 4 holding points.
Set made up of one metalic base on which to install the electric strike and a sturdy protective box. This protective box is designed so that the points of union of the electricstrike and the door frame are not visible, ensuring the shield of the electric strike.
Installation instructions:
1- Place the electric strike on the metalic base.2- Place the C-83 accessories under the metalic base until the latch gets aligned.3- Pass the electric cable through the holes of the C-83 accessories and the metalic
base.4- Place the set on the door frame at 12-14 mm. from the panic device.Hold them with
2 screws.5- Make the electrical connection of the electric strike.6- Protect the set with the shielded box 85. Hold the box on the door frame with 4
screws.7- Press the black nylon trim on top of the shielded box 85 in order to hide the 4
holding points.
BLACK
BLACK
RED
RED
82
83
82
83
Latch and electric strike aligment
Part of the door frame will be cut to facilitate the turning of the elec-tric strike latch.
installation example
4
BLACK
RED
85
85
C83
48
43
160
2
160
27,35
160
160
27,35
44,65
67
1
2
3
5
13
16,5 mm symmetrical mini electric strikes compact and high-strength
References and featuresReversible
Radial turning latch
Fail-secure
Fail-secure with mechanical unlatching
Fail-secure with microswitch
Fail-safe
Fail-safe with microswitch
The electric strike is locked when unenergized.
It works just like the Fail-secure model but with mechanical release function.
It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.
The electric strike remains in closed position, while the coil is selected. When the electric current is stopped, the electric strike stays in open position.
Like the Fail-safe model plus an electrical switching device that detects the status of the door.
Adjustable latch Preload Electronic
protection Voltage Referenceslatch (1)add faceplate
9-16 V ac/dc
9-16 V ac/dc
9-16 V ac/dc
12 V dc
12 V dc
6-12 V ac/dc
6-12 V ac/dc
12 V dc
24 V dc
24 V dc
12 V dc
12 V dc
24 V dc
24 V dc
24 V dc
50.1.00.B
51.1.00.B
56.1.00.B
50.1.00.J
51.1.00.J
56.1.00.E
50.1.00.E
51.1.00.E
56.1.00.F
50.1.00.F
51.1.00.F
54.1.00.E
58.1.00.E
54.1.00.F
58.1.00.F
Coil features
Dimensions
Technical features
7785
60
46
°C
Minutes 5
16 Vac
12 Vac
12 Vac
9 Vac9 Vac
6 Vac
(20 Ω 0,480 A a 12V ac) (8,5 Ω 0,820 A a 9V ac) (42 Ω 0,275 A) (192 Ω 0,120 A)9/16 V ac/dcB
58
39
°C
Minutes 5
6/12 V ac/dcJ
68
62
°C
Hours 5
12 Vdc 100%E
°C
Hours 5
24 Vdc 100%F
Electric strikes with «ac» coils work properly even with a pressure up to 16Kg.
300.000 guaranteed openingsReinforced anchor levers
Withstands impacts up to 400 Kg.
Steel screws
Low power consumption
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).
Fail-secure Fail-securewith mechanical unlatching
with mechanical unlatching
Fail-secure with microswitch
Fail-safewith microswitch
Hold-open Hold-open Fail-safe
Warning:
When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.
Incorrect installation could cause door-release failure.
Temperature test:
Measured on coil surface, tolerance ±10%
Other coils and voltages on demand
5,9
9,8
9,8 1
3
46,6
16
5,9
9,89,8 13
46,6
Hold-open
Hold-open with mechanical unlatching
The electric strike has a device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.
It works just like the Hold-open model but with mechanical release function.
9-16 V ac/dc
9-16 V ac/dc
6-12 V ac/dc
6-12 V ac/dc
52.1.00.B
52.1.00.J
53.1.00.B
53.1.00.J
new
65,5
16,5
72,55
28,1
14
6
65,3
48,3
130,2
44,5
33,2
227,5
44,5
48,3
18,8
32,5
66,5
24,3
33,2
12,1
2
R10
243,9
66,5
2,1
227,5
3
66,5
24,3
12,1
24
INOX 3mm
INOX 3mm
INOX 3mm
INOX 3mm
INOX 3mm22
24
26
25
23
DINRight Left
DINRight Left
Reversible
24
15
IP54 waterproof electric strikes
References and features
Fail-secure
Fail-secure with 1 microswitch
Fail-safe
Fail-safe with 1 microswitch
Internal Hold-open
The electric strike is locked when unenergized.
It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.
The electric strike remains in closed position, while the coil is selected. When the electrical current is stopped, the strike stays in open position.
It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.
The electric strike has an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.
PreloadElectronic protection
Fixed latch Voltage
8-14 V ac/dc
8-14 V ac/dc
9-14 V ac/dc
12 V dc
12 V dc
12 V dc
24 V dc
24 V dc
12 V dc
24 V dc
24 V dc
7L0.4.00.L7R0.4.00.L
7L6.4.00.L7R6.4.00.L
7L6.4.00.M7R6.4.00.M
7L4.4.00.M7R4.4.00.M
7L6.4.00.N7R6.4.00.N
7L4.4.00.N7R4.4.00.N
7L0.4.00.M7R0.4.00.M
7L0.4.00.N7R0.4.00.N
7L8.4.00.M7R8.4.00.M
7L8.4.00.N7R8.4.00.N
7R2A.4.00.L 7L2A.4.00.L
ReferencesDIN leftadd faceplate
ReferencesDIN rightadd faceplate
Coil features
21,2
93,2
98,9
36
4,3
Fail-secure Fail-safe Internal Hold-open
Schematic electric diagram with microswitch
Dimensions
D D D D DI I I I I
Security coil support
®
100% waterproof box
®
Magnet + 100% waterproof REED
®
Power supply
Push button
Push button
light light
NC
NC
CO
M
CO
M
NO
NO
CO
IL
CO
IL
Technical featuresElectric strikes with «ac» coils work properly even with a pressure up to 15Kg.
Waterproof mechanism box
Withstands impacts and pressures up to 300 Kg, getting destroyed at 500kg.
300.000 guaranteed openings.
Reinforced mechanism box
Low power consumption.
Stainless steel screws.
Protected against water projected in all directions (IP54).
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).
25
250
3
40,5
45,5
13
85
12
15
73,5
131
253
2504
0,5
13
15
85
131
45,5
73,5
INOX 3mm INOX 3mm INOX 3mm68 69 75Reversible Reversible Reversible
Door Handedness DIN definition:The door is viewed from the side on which the hinges are visible.
°C
Minutes 5(a 12 Vac)
(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL
6266
°C
Hours 5
(70 Ω 0,17A) 12 Vdc 100%M
°C
Hours 5
(240 Ω 0,10A) 24 Vdc 100%N
62
5156
Warning:
When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.
Incorrect installation could cause door-release failure.
Temperature test:
Measured on coil surface, tolerance ±10%
Fail-secure Fail-safe1 microswitch
Other coils and voltages on demand
FAIL-SAFEFAIL-SAFE
FAIL-SECUREFAIL-SECURE
27
27
27
250
313
40,5
73,5
45,5
131
20
16
References and features
Fail-secure
Internal Hold-open with mechanical unlatching
Fail-safe
The electric strike is locked when unenergized.
The electric strike has a an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door and has mechanical unlatching.
The electric strike is locked when energized.
Adjustablelatch Preload Electronic
protection Voltage
8-14 V ac/dc
9-14 V ac/dc
24 V dc
12 V dc
12 V dc
24 V dc
9L0.1.00.L9R0.1.00.L
9R0.1.00.M
9R0.1.00.N
9R4.1.00.M
9R4.1.00.N
9R3A.1.00.L
9L0.1.00.M
9L0.1.00.N
9L4.1.00.M
9L3A.1.00.L
9L4.1.00.N
ReferencesDIN leftadd faceplate
ReferencesDIN rightadd faceplate
Coil features
Fail-secure Fail-safeInternal
Hold-open
D D DI I I
Operation Dimensions
77
36,3
32
23
83
88,5
Technical features
Faceplates
Designed for bolts-locked armoured doors.
4mm. distance between the latch and the first bolt of the electric strike.
Withstands impacts and pressures up to 400 Kg, getting destroyed at 700kg.
300.000 guaranteed openings. Reinforced mechanism box
Low power consumption. Steel screws.
Electric strikes with 12V ac coils are released by applying a pressure up to 16 kg
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).
Latch adjustment regulator (is supplied on demand)
Stainless steel lock cover
Door Handedness
35 3
247
O 20
68,5
37
141,5
INOX 3mm 70
35 3
247
O 20
68,5
37
141,5
INOX 3mm 60Reversible Reversible
opened closed
°C
Minutes 5(a 12 Vac)
(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL
6266
°C
Hours 5
(70 Ω 0,17A) 12 Vdc 100%M
°C
Hours 5
(240 Ω 0,10A) 24 Vdc 100%N
62
5156
Warning:
When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.
Incorrect installation could cause door-release failure.
Temperature test:
Measured on coil surface, tolerance ±10%
internal hold-open
Adjustable latch (3mm)
34,8 9,3
10,814,2
34,8 6
10,814,2
Standard adjustable latch Ref. 1
Deep adjustable latch Ref. 3
Other coils and voltages on demand
DIN definition:The door is viewed from the side on which the hinges are visible.
FAIL-SAFEFAIL-SAFE
FAIL-SECUREFAIL-SECURE
security electric strikesfor armoured doors
17
52
9,2
11
106,4
29,5
20,5
3,5
45107
UNE EN 1634-1, RF120References and features
Fail-secure
Fail-secure with 1 microswitch
Fail-safe
Fail-safe with 1 microswitch
The electric strike is locked when unenergized.
It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.
The electric strike is locked when energized.
It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.
PreloadElectronic protection
Fixed latch Voltage
8-14 V ac/dc
8-14 V ac/dc
12 V dc
12 V dc
12 V dc
24 V dc
24 V dc
12 V dc
24 V dc
24 V dc
24L0.4.00.L24R0.4.00.L
24L6.4.00.L24R6.4.00.L
24L6.4.00.M24R6.4.00.M
24L4.4.00.M24R4.4.00.P
24L6.4.00.N24R6.4.00.N
24L4.4.00.N24R4.4.00.N
24L0.4.00.M24R0.4.00.M
24L0.4.00.N24R0.4.00.N
24L8.4.00.M24R8.4.00.P
24L8.4.00.N24R8.4.00.N
ReferencesDIN leftadd faceplate
ReferencesDIN rightadd faceplate
Faceplates
Door Handedness
Dimensions
Schematic electric diagram con microswitch
Fail-secure Fail-safe
D D D DI I I I
Push button
Door openedDoor closed
Power supply
Principal microswitch S1
light
NO
COM
NC
Technical featuresHeat resistance: 1150 ° C for 2 HoursApproval standard UNE EN 1634 - 1, RF 120
Stainless steel lock cover
Withstands impacts and pressures up to 1000 Kg
300.000 guaranteed openings
Reinforced mechanism box
Stainless steel screws
Low power consumption
Electric strikes with 12V ac coils are released by applying a pressure up to 16 kg
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).
159
253
52
44
65,5
49,5
ReversibleINOX3mm61 INOX
3mm66
200
52
253
44
65,5
90,5
Coil features
°C
Minutes 5(a 12 Vac)
(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL
6266
°C
Hours 5
(70 Ω 0,17A) 12 Vdc 100%M
°C
Hours 5
(240 Ω 0,10A) 24 Vdc 100%N
62
5156
Warning:
When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.
Incorrect installation could cause door-release failure.
Temperature test:
Measured on coil surface, tolerance ±10%
Operation
opened closed
Fail-secure Fail-safe
1 microswitchFail-secure Fail-safe
openedclosed
steel electric strikesfor RF-120 doors
Other coils and voltages on demand
DIN definition:The door is viewed from the side on which the hinges are visible.
FAIL-SAFEFAIL-SAFE
FAIL-SECUREFAIL-SECURE
18
symmetrical steel electric strikesHigh-security (1000 Kg)
References and featuresReversible
Radial turning latch
Fail-secure
Fail-secure with 1 microswitch
Hold-open
Fail-safe
Fail-safe with 1 microswitch
The electric strike is locked when unenergized.
It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.
The electric strike has a device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.
The electric strike is locked when energized.
It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.
Adjustablelatch Preload Electronic
protection Voltage Referenceslatch (1)add faceplate
8-14 V ac/dc
8-14 V ac/dc
5-12 V ac/dc
8-14 V ac/dc
12 V dc
12 V dc
5-12 V ac/dc
12 V dc
5-12 V ac/dc
24 V dc
24 V dc
12 V dc
24 V dc
24 V dc
250.1.00.B
256.1.00.B
256.1.00.J
250.1.00.J
256.1.00.E
250.1.00.E
256.1.00.F
250.1.00.F
252.1.00.B
252.1.00.J
254.1.00.E
258.1.00.E
254.1.00.F
258.1.00.F
Dimensions
Fail-secure Fail-secure with microswith
Fail-safewith microswith
Hold-openFail-safe
11,6
5
6
2
11,6
5
11,6
5
15,3
43,8
11,6
5
15,3
43,8
Technical featuresElectric strikes with «ac» coils work properly even with a pressure up to 16Kg.
300.000 guaranteed openingsSteel levers
Withstands impacts and pressures up to 1000 Kg
Steel screws
Low power consumption
Corrosion resistant according to UNI ISO 9227 Standards
Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).
Coil features
105
°C
Minutes 5(a 12 Vac)
(14 Ω 0,7 A a 12 Vac) 8/14 V ac/dcB
65
°C
Minutes 5(a 9 Vac)
(8 Ω 0,6 A a 9 Vac) 5/12 V ac/dcJ
Warning:
When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.
Incorrect installation could cause door-release failure.
Temperature test:
Measured on coil surface, tolerance ±10%
new
70
28
78,5
20,5
20,5
0,5
28,5
53
°C
Hours 5
(50 Ω 0,25 A) 12 Vdc 100%E
77
°C
Hours 5
(185 Ω 0,12 A) 24 Vdc 100%F
Other coils and voltages on demand
19
new
faceplatesfor symmetrical steel electric strikes
Reversible
159
253
52
44
65,5
49,5
INOX 3mm61Reversible
INOX 3mm66
200
52
253
44
65,5
90,5
25
30,7
548,5
30,7
5
44
110
3
52
INOX 3mm62
Reversible
Reversible
63 D63 C63
25
61,7
548,5
139,7
5
12
79
35
44
250
3
52
INOX 3mm 65 D65 C65
Reversible
25
61,7
548,5
139,7
5
102
12,544
250
12
3
52
64 D64 C64
25
61,7
548,5
139,7
5 17
44
12,5
102
250
3
52
Right LeftDIN
INOX 3mm73 74
52
34
64
48
128
14
90
124
4
240
2
BROWN17
Reversible
R10
R 10R 10
R10
52
Reversible
BROWN16
48,5
25
32
44
172
R10
R10
R 10 R 10
52
12
R10 R
10
R 10R 10
52
12
Right LeftDIN
BROWN12 13
12
102
44
250
32 25
2
250
44
12
102
48,5
2
32
25
Right LeftDIN
BROWN08 09
20
electromagnetic locks
micro electromagnetic locks
magnetic door holders
mini electromagnetic locks
universal electromagnetic locks
IP65 waterproof mini electromagnetic locks
shearlocks
new
new
21
electromagnetic locks
micro electromagnetic locks
magnetic door holders
mini electromagnetic locks
universal electromagnetic locks
IP65 waterproof mini electromagnetic locks
shearlocks
new
new
micro electromagnetic locksfor lockers, drawers, cabins, etc
32,5
39,5
24
90
Dimensions
Electrical connection
Holding force: 700 N
MEX70
MBAX70
Power supply 12Vdc - 340mA
Power supply 24Vdc - 165mA
ZBracket
38
75
38
38
4,5
For doors that open inwards
UBracket
41
70
16
28
MHAX70
For glass doors
new
69,2
32,9
7
22
magnetic door holders
References
DHI Industrial door holder
DHS Basic door holder
DHB Dual tension door holder
DHT Timed door holder
DHD Door holder with power-regulation
DFS Door holder support
Dimensions Technical features
Diameter: 50mm.Holding force: 600 NPower supply: 24 VdcElectric connexion: 2 wires
side or rear exit24Vdc consumption: 0,085 APower: 2 W
Diameter: 50mm.Holding force: 600 NPower supply: 12/24 Vdc12Vdc consumption: 0,170 A24Vdc consumption: 0,085 AVoltage change: with jumperPower: 2 WPush button to unlock the door
Diameter: 50mm.Holding force: 600 NPower supply: 24 VdcTimer: 3 seg.24Vdc consumption: 0,085 APower: 2 WPush button to unlock the door
Diameter: 50mm.Max. Holding force: 600 NMin. Holding force: 300 NPower supply: 24 Vdc600N consumption: 0,085 APower: 2 WPush button to unlock the door
new
24,7
O50
7O55
28
60
60
O50
15
60
60
O55
65
65
55
51
46,2
83
90
,42 5
O50
39
8080
83
39
90
83
192
65
65
65
65
5555
51
51
46,2
46,2
83
83
90
90
,42 5
,42 5
O50
O50
All models are equippedwith ejector pins to overcome residual magnetism
23
mini electromagnetic locks
References and featuresElectronic protection
Holding force
Installation Mortise Rim
References
ME-200/210
ME-201/211
ME-400/410/420
ME-600/610/620
Packaging dimensions Total weight
1,8 Kg
1,8 Kg
1,8 Kg
4 Kg
500 mA
500 mA
500 mA
500 mA
250 mA
250 mA
250 mA
250 mA
6 W
6 W
6 W
6 W
Electric consumption12 Vdc 24 Vdc Power
Fitting system round squared Led Reed Voltage
12/24 VdcReferences
2800 N
2800 N
2800 N
2800 N
2800 N
2800 N x 2
2800 N
2800 N
2800 N x 2
2800 N x 2
ME-200
ME-201
ME-210
ME-211
ME-400
ME-410
ME-420
ME-600
ME-610
ME-620
40
305105
40
305105
40
305105
40
550105
249
202 26
26202239
26535
40
202
525
30
30
35
31
24
brackets for mini electromagnetic locks
50185
35
12
265
References and features
Wiring and voltage switching
Brackets for mini electromagnetic locks
for outwardopening doors
Brackets L Z UBrackets Brackets
for inwardopening doors
for glass doors
Brackets for double mini electromagnetic locks Base for RF door Finish selection chart
Installation and features of the electric strike faceplate
50
50265
50
50525
5050
50270
26
39
190MBE-806
MBE-807 MRF-810 FSC-821
MBA-801 MHA-804
MBA-802
REED SWITCH FEATURES REED SWITCH CONTACTS REED SWITCH CONTACTS
VOLTAGE CHANGE
JUM
PER
JUM
PERS
JUMP CONNECTOR SET VOLTAGE
MAXIMUM SWITCHING VOLTAGE 100 VDC (VOLTS DC)MAXIMUM SWITCHING CURRENT 0.3 A (AMPS DC)MAXIMUM CONTACT RATING 3 W (WATTS DC)
JUMP CONNECTOR SET VOLTAGE JUMP CONNECTOR SET VOLTAGE DC POWER INPUT DC POWER INPUT
LED
DC POWER INPUTCorrect position of voltage selection jumpers
Voltage selection pins
Door properly lockedDoor improperly locked(electric strike plate incorrectly positioned)Electromagnetic lock out of order(failure on the electric power supply)
L B H L1 D1 D2HOLDING FORCE
MEASURES
2800 N 185 35 12 165 17 9
D2
D1
H
Ø 5,5Ø 5,5
3
L1
L
B
Warning: Do not fasten the center screw too tightly. The plate must be loose.
HEX BOLT
Hex bolt
Joint
Washers
Armature
Screw
Hex bolt2 JointsScrew
Stringer2 Washers
Door
Stringer
Armature fastening holes
HEX BOLT
WASHER
ARMATURE
SCREW
JOINT JOINT JOINT
SCREW SCREW
ARMATURE ARMATURE
WASHER WASHER
DOORDOORDOOR
The armature must be fastened exactly as shown above.
Fixing the armature to a steel, PVC or aluminium profile.
The parts shown above are delivered with each magnet.
Fixing the armature on a wooden door.Fixing the armature on armoured steel doors.The steel needs to be thick enough to fastenthe screw on the steel door.
If the steel is not thick enough, the plate mustbe fastened with the hex bolt.
25
universal electromagnetic locksReferences and features
Electronic protection
Timer from2 to 8 sec.
Holding force
Electric consumption12 Vdc 24 Vdc
Installation Mortise Rim
Security device
Dual voltage 12/24 Vdc changing automatically
Voltage12 Vdc ReferencesLed Reed
1800 N
3000 N
6500 N
3000 N
3000 N x 2
6500 N
3000 N
3000 N x 2
6500 N
MEX-100
MEX-201
MEX-400
MEX-430
MEX-600
MEX-630
MEX-700
MEX-730
MEX-900
Dimensions Packaging dimensions Total weight
1,2 Kg 250 mA 3 W
2,15 Kg 270 mA 3,3 W
2,25 Kg 270 mA 180 mA 3,3 W
2,25 Kg 270 mA 180 mA 3,3 W
4,4 Kg 270 mA 180 mA 3,3 W
4,4 Kg 270 mA 180 mA 3,3 W
4,1 Kg 270 mA 180 mA 3,3 W
4,1 Kg 270 mA 180 mA 3,3 W
4,5 Kg 270 mA 180 mA 3,3 W
Power
MEX-100
37
295120
37
295120
37
295120
37
295120
37
520120
37
520120
50
308160
50
308160
50
308160
MEX-201
MEX-400
MEX-430
MEX-600
MEX-630
MEX-700
MEX-730
MEX-900
22
23
28
28
28
28
40
46
52
52
52
52
166
248
241
241
417
417
265
265
265
315
70
70
65
35
35
40
228
26
brackets and accessories
Brackets for 180 Kg electromagnetic locks
Brackets for 300 Kg electromagnetic locks
Brackets for 600 Kg electromagnetic locks
Installation and features of the electric strike faceplate
References and features
MBEX-180 MBAX-180(3 units)
MHAX-180
MHAX-300MBAX-300(3 units)
MBAX-600(3 units)
MBEX-300
MBEX-600
for outwardopening doors
Brackets L ZBrackets
for inwardopening doors
UBrackets
for glass doors
40
35166
45
35240
75
40265 75
43
70
40
65
180
265
HOLDING FORCE
MEASURES
1800 N 135,5
L B H L1 D1 D2
31,5 8,6 120 Ø10 Ø5,6
Ø16 Ø 9
Ø16 Ø 9
160 45,3 12,6 140
175 62 13,6 150
3000 N
6000 N
20
20
40
40
135
160
D2
D1
H
Ø 5,5Ø 5,5
3
L1
L
B
Warning: Do not fasten the center screw too tightly. The plate must be loose.
HEX BOLT
Hex bolt
Joint
Washers
Armature
Screw
Hex bolt2 JointsScrew
Stringer2 Washers
Door
Stringer
Armature fastening holes
HEX BOLT
WASHER
ARMATURE
SCREW
JOINT JOINT JOINT
SCREW SCREW
ARMATURE ARMATURE
WASHER WASHER
DOORDOORDOOR
The armature must be fastened exactly as shown above.
Fixing the armature to a steel, PVC or aluminium profile.
The parts shown above are delivered with each magnet.
Fixing the armature on a wooden door.Fixing the armature on armoured steel doors.The steel needs to be thick enough to fastenthe screw on the steel door.
If the steel is not thick enough, the plate mustbe fastened with the hex bolt.
26
40166
33
52240
45 45
40135
50 50
50160
27
Electronic protection
Holding force IP65
Installation: Rim
References
ME-500
ME-510
Packaging dimensions
Product especially designed for outdoor installations. IP65 approval and total protection against weathering.
Total weight
1,9 kg
1,9 kg
1100 mm.
1100 mm.
500 mA
500 mA
250 mA
250 mA
6 W
6 W
PowerCable length
Electric consumption 12 Vdc 24Vdc
Chrome finish
Fitting system squared Reed Voltage
12/24 VdcReferences
2500 N
2500 N
ME-500
ME-510
References and features
305
305
40
40
105
105
D2
D1
H
Ø 5,5Ø 5,5
3
L1
L
B
Dimensions
Connections
Brackets for mini electromagnetic locks
ME-500ME-500
ME-510ME-510
MBE-806
MBE-808
MBE-801
MBE-802
24 V dcwithout polarity
12 V dcwithout polarity
24 V dcwithout polarity
12 V dcwithout polarity
contactsrelay «REED»
contactsrelay «REED»
5050
50270
50
34
50
34
265
265
NO NO
C C
NC NC
grey grey
4 drills D=5,2 for plain faced screws(DIN 965 or similar)
white white
red redgreen greenyellow yellow
blue blue
black black
brown brown
red redblue blueyellow yellow
4 or 7 wires depending on the model
IP65 waterproofmini electromagnetic locks
L B H L1 D1 D2HOLDING FORCE
MEASURES
2500 N 185 35 12 165 17 9
28
What is a shearlock and how it works
Example of use
Dimensions
Rim
Mortise
Glass door
A shearlock is an electromagnetic lock that combines magnetic and mechanical force, generating a holding power of up to 15.000N.
It can be installed on all kinds of left and right handed doors (metal, wooden and glass), either horizontally or vertically. It is the ideal lock for swing doors and emergency doors equipped with panic devices.
A magnetic sensor detects when the door and doorframe are aligned and makes the shearlock lock the door in place. When a sherlock is deactivated via an access control system or a button, the door is released. If, however, the door is no physically open within the T1 progra-mmed time (closing delay), the shearlock will automatically lock the door again. Otherwise, the door can be kept unlocked for a specific time simply by interrupting the power supply.
Shearlocks operate on 10-36V dc, so the installer does not have to set the voltage. They have two power connections and an adjustable delay system, which means a delay between 1 and 25 seconds for realease and locking can be set.
Shearlocks are designed to be connected for instant-release buttons, traffic lights, access control systems, radio alarms and even heat and smoke detectors, in order to release the door immediately in case of fire.
There is an attempted robbery in a department store and the thief tries to escape through an emergency door with a panic device and a shearlock.
When the thief pushes the panic bar, the door will still be locked by the shearlock for the programmed time, and a warning signal can be sent to the store’s emergency control center. If the system is equipped with an acoustic alarm, it will be ringing for the time the shearlock is programmed to. When the thief discovers the door is locked, he will be forced to drop the goods.
Once the door is released, the store’s security personnel will have to reset the shearlock to stop the alarm and reset the system.
Different installation possibilities
A) Rim
Door only opens one way
Swing door
B) Mortise
Door only opens one way
Swing door
Shearlock for glass doorModel: SH300
A) Shearlock surface mountedB) Shearlock glass doorModel: SH400
A) Shearlock built-inB) Shearlock glass doorModel: SH500
C) Glass and swing doors
Mixed installation Mixed installation
Model: SH100Silver
Model: SH200Grey
shearlocksfor swing and sliding doors
A
B
A
B
29
Electrical features:
Power supply:10-36 V dc, there is no need to set the voltageConsumption for 12 V dc 2A startup and 0,5 A operating current.
Coil:Tropicalized.
Autoprotection:If the closing manoeuvre is not executed correctly because there is a defect in alignment or there is an object preventing closure, the system tries to close seve-ral times. If after five attempts the shearlock cannot be closed, it remains in the open position and triggers an alarm. This prevents the product from overheating, which causes the deterioration of the product.
Auxiliary relay: Inversion circuit. Maximum current: 1 A at 24 V dc.When activated, the door is locked.When deactivated, the door is released.
Time delays:When locking/ aligning: 4 sec. ( adjustable from 0 to 25 sec )When releasing/ in an emergency: 15 sec ( adjustable from 0 to 25 sec )The adjustments can be independent from each other. Values shown are factory default settings.
Additional features:Locking prevention: this connection keeps the door released, even though the power is connected.Opening delay: either through an instantaneous connection or a button with timed opening.
Alarms:Intermittent alarm:
The electromagnet and door plate are not aligned.Attempted forced entry.Coil malfunction.Position sensors not aligned.Alarm indications are cancelled after 15 sec. or disconnecting the power supply.
Continuous alarm:Indicates the countdown to door release.Deactivates through the locking-prevention system or by disconnecting the power supply.
3 color LED indicator:Green: door released.Red: door closed.Amber: malfunction or transitory state.
Warning:Maximun space between parts = 3 mm
Magnetic alignment sensors
Power supply connectionLEDT2 Release-delay adjustmentFOR PANIC DEVICES
T1 Locking-delay adjustment
External alarm circuit:4 + Common with the shearlock8 - Auxiliary through the transistor in the shearlock circuitMaximum current: 350mA
Pulsador apertura instantánea y reset4 + Common with the shearlock3 Active
Power supply (10 to 36 VDC)
Emergency release delay
Auxiliary ( - )Alarm ( - )
Relay
1 A at 24 V
Immediate release and reset auxiliary ( + )
Transistor within the shearlock’s own electronic circuit
Model SH-200Model SH-100
30
shearlocksfor glass doors
Model: SH-300
Installation instructions
Installation example
Warning: Maximum space between parts = 3 mm
1) Ensure the separation between the two glass plates (fixed part and moving part) is 6,5 mm or more. 2) Install the two parts of the shearlock so they are perfectly aligned and parallel.3) For the sensor to detect when the door is closed, the separation between the two parts of the shearlock should not exceed 3 mm.
LOCKINGM6 allen key (2 units)3 mm spanner
INSTRUCTIONS
1. Remove the protective backing.2. Put the bracket in place.3. Remove the two locking screws. 4. Use the set screw to push the bearing strip forward until it exerts pressure on the glass.5. Insert and tighten the locking screws until they lock into the set screws.
Adhesive strip withprotective backing
BERING STRIPFOR THE GLASS
SET SCREW FOR BERING STRIPFOR THE GLASS (2 units)M6 allen key3 mm spanner
Power supply
Hydraulicspring
Traffic light
Coded access controlAC-100
Power supply from 10 to 36 VdcMaximum current: 2,5 A at 10 VOperating current: 0,5 A at 10 VStabilized direct currentObserve connection polarity
Traffic light
31
other products and accessories
traffic lights for access control systems
flex tube and joints
provisional latch
power supplies
motorized RIMTOPLOCK
new
new
new
32
traffic lights for access control systems11
0
40
80
2618,6
129,
5 80
4040
4,5
11
1422
Jumper operation
Traffic lights dimensions Box dimensions
10-24 V ac/dc(flashing or steady light mode)
10-24 V ac/dc(flashing or steady light mode plus audible warning device)
Electrical connection
TLX001 TLP002 TLB001 TLB002
2 LEDS(Red and green)
2 LEDS(Red and green) + push button
2 LEDS(Red and green) + audible warning device
2 LEDS(Red and green) + push button + audible warning device
The audible warning device and the LED light remains in flashing mode.
the audible warning device and the LED light remains in steady mode.
Non polarized power supply 10-24 Vac / dc COM
Green LED contact
Red LED contact
without jumper with Jumper
new
33
flex tubes and joints
39
47
22
39
47
22
Model
EFX150 14,5 mm
14,5 mm
14,5 mm
14,5 mm
14,5 mm
14,5 mm
14,5 mm
14,5 mm
Steel 150 mm
150 mm
320 mm
500 mm
200 mm
200 mm
400 mm
400 mm
250 mm
250 mm
420 mm
600 mm
300 mm
300 mm
500 mm
500 mm
SFX250 Steel
SFX420 Steel
SFX600 Steel
BFX500G
BFX500B
DDC002
BFX300G
BFX300B
Grey boxSteel Flex tube
Brass boxSteel Flex tube
Grey boxSteel Flex tube
Brass boxSteel Flex tube
Diameter Finish color Flex tube lenght Total lenght
References and features
Dual electrical joints Electrical features
Maximum voltage: 24 V ac/dcMaximum intensity: 1,5 A. ac/dc
6
11
13
70
58
11
6
new
References and features
34
provisional latches
For faceplates located on building sites
The CSR001 provisional latch can be installed in all OPENERS & CLOSERS faceplates
Provisional latch CSR001 (3mm adjustable)
faceplate 03 faceplate 03 + CSR001
During construction work, it is possible to install a provisional latch CSR 001 that will leave the faceplate ready for the installation at the corresponding electric strike.
The latch replacement CSR 001 allows to keep the doors closed during the construction process, and is supplied with the 3 mm adjustable latch.
52,3
44,75,4
12,6
12,6
Dimensions
new
35
power supplies
References and featuresPower supplies at DC current
Power supply at AC current
Input Output Output Stability Protection Degree Power Battery Battery Capacity References Voltage Voltage Current Charge
230 V 50/60Hz 12 V dc 6 A dc 3% IP20 80 W yes PS 901*
230 V 50/60Hz 24 V dc 3 A dc 3% IP20 80 W yes PS 902*
230 V 50/60Hz 12 V dc 6 A dc 3% IP20 80 W yes 12 V dc 7 Ah PS 905**
230 V 50/60Hz 24 V dc 3 A dc 3% IP20 80 W yes 24 V dc 4 Ah PS 906**
230 V 50/60Hz 12 V dc 3 A dc 3% IP20 30 W PS 907*
230 V 50/60Hz 24 V dc 1,5 A dc 3% IP20 30 W PS 908*
High efficiency (77-87%) switching power supplies.Temperature operation between 0° - 40°CSingle output, over voltage, over heating and short circuit protection.Double function: power supply and batteries charging “on line” system, with complete discharge protection
* Finish DIN rail 35 x 7.5 ( DIN 500 22 )** 4 terminals for 2 electromagnetic locks each, with switches and operation warning light controls.
230 V 50/60Hz 12 V ac 1,5 A ac IP20 18 VA PS 903*
PS 901
PS 902
PS 907 PS 905
PS 908
PS 906
PS 903
36
motorized RIMTOPLOCK
When the door is aligned with the frame, the magnetic detector located at the (front) lock box, blocks the door.
Once the lock is released, and during the scheduled opening time, the lock makes an intermittent warning sound. After a scheduled time, the lock blocks automatically.
An acoustic alarm warns when the door is not properly closed.
General operation:
CE-104
CE-105
CE-106
CE-109
VCX-100 Rain-protection steel visor
Dimensions and electric diagram
Warning: The distance between the electric strike and the front box should be 5 mm. Distance plastic controller included.
Features and functional description• Mechanical opening handle
• Push button for electrical opening
• External cylinder for key opening
• Reversible, 60 mm cylinder
• 12 V dc power supply
• 500mA energy consumption
• 350.000 guaranteed openings
ENTRY: 1) Access control opening 2) Key opening
EXIT: 1) Electrical opening using the red push button 2) Electrical opening using access control 3) Mechanical opening using lock handle
IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit using lock handle
Features and functional description• Mechanical opening handle
• External cylinder for key opening
• Reversible, 60 mm cylinder
• 12 V dc power supply
• 500mA energy consumption
• 350.000 guaranteed openings
ENTRY: 1) Access control opening 2) Key opening
EXIT: 1) Electrical opening using access control or pressing the button 2) Mechanical opening using lock handle
IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit using lock handle
Features and functional description• Internal and external cylinder for key opening
• Reversible, 60 mm cylinder
• 12 V dc power supply
• 500mA energy consumption
• 350.000 guaranteed openings
ENTRY: 1) Access control opening 2) Key opening
EXIT: 1) Electrical opening using access control or pressing the button 2) Mechanical opening using keys
IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit with keys
Features and functional description
• Mechanical opening handle
• Push button to lock / unlock permanently
• External cylinder for key opening
• Reversible, 60 mm cylinder
• 12 V dc power supply
• 500mA energy consumption
• 350.000 guaranteed openings
ENTRY: 1) Access control opening 2) Key opening
EXIT: 1) Electrical opening using access control or pressing the button 2) Mechanical opening using lock handle
IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit using lock handle
The lock remains in permanent unblock position pressing the green button. The lock becomes operative again with a second press, which cancels the permanent unblock.
Blue (-)Red (+)12V dc
9442
58
80
40
96100
129,5
126
4155
a
a
Lock Motor
Green
RedRed
Door sensor
Pushbutton
Exteriorpushbutton
Lock switchpush button
Door sensor
Green
Lock Motor
37
In the interest of improving the quality of our products, Openers & Closers reserves the right to modify or upda-te the information provided in this catalogue.