101-de exit check delayed egress controller · the integral verbal message, digital countdown...
Post on 04-Nov-2019
4 Views
Preview:
TRANSCRIPT
WWW.SDCSECURITY.COM ■ SECURITY DOOR CONTROLS
Security Door ControlsACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 1
The integral verbal message, digital countdown display and sign pro-vide comprehensive and clear instructions of the door operation for persons without prior knowledge of the exit delay, including the sight and hearing impaired. The digital keypad eliminates the need to carry and locate keys for reset and bypass functions.
101-DE Exit Check® Delayed Egress Controller
• STOP EMPLOYEE THEFT• STOP RETAIL SHOPLIFTING• RESTRICT AIRPORT PATRONS• RESTRICT WANDERING PATIENTS
VERBAL EXIT INSTRUCTIONS OR ALARM TONE ONLY& DIGITAL COUNTDOWN DISPLAY
EGRESS DELAY• 15or30secondexitdelay• 1or2secondnuisancedelayBUILT-IN 3 FUNCTION KEYPAD • Alarmandlockreset• 1to30secondbypass• Sustainedbypass•AdditionalkeyswitchoptionalCONTROL INPUTS• 1to30secondrequest-to-exit
and access bypass with anti-tail-gate
• Alarmreset • Infantandwanderingpatientpro-
tection system compatibility• ExternalDPSinputforanti-tail-
gate and door prop operationBUILT-IN ANNUNCIATION • Armedmode• Nuisancemode• Irreversibleegressmode• Releasemode• Digitalcountdowndisplay• Fieldselectablevoicenotification
or tone• Fieldselectablemalevoicewith
security message or female voice with safety message
MONITORING OUTPUTS• Armedstatus• Egressinitiationstatus• ReleasedstatusOPTIONAL EMLOCK OUTPUTS • Doorpositionsensor-indicates
door open and door closed, com-monly used to verify egress after release
• Magneticbondsensor-indicateslocked with full holing force, low holding force, unlocked and tam-pering
CHOICE OF MOUNTING• Recessedmounted (3gangplasterringincluded)
• Surfacemountedwithoptional 3gangbox(DEC-J)
TRIGGER MODES• EgressalarmtriggeredbydoormovementwhenusedwithSDC1500DEseriesEmLocks.
•Triggerinputfromexternaldevicefieldselectable(n/oorn/c)
POWER-UP MODES• Fieldselectableautomaticor
manual power up after emergen-cy release or power loss. Use of manual power up complies with CaliforniaBuildingCode(OSHPD)requirements
MODELSFEATURESDELAYED EGRESS CONTROLLER101-DE Wall mount controller with keypadcontrolandreset,180mA@12/24VDC
101-KDE Wall mount controller with both keypad and keyswitch controlandreset(lesscylinder)
Magnetic Lock with Activation Sensor Specify 2 for pair of doors
INDOOR LOCKS1511DEVSingle,1650lbsholdingforce,670/350mA@12/24VDC, 628finishstandard
1571DEVSingle,1200lbsholdingforceEnergySaver,250/125mA@12/24VDC, 628std
1581DEVSingle,650lbsholdingforce,440/220mA@12/24VDC, 628finishstandardINDOOR/OUTDOOR LOCKS WITH ACTIVA-TION SENSOR AND CONDUIT FITTING
1575DEUSinglemagneticlockwithmagneticbondsensor,630finishstandard
1576DEUSinglefacedrilledmag-netic lock with magnetic bond sen-sor,630std
3774-0324:103CaliforniaStateFireMarshallListedCFSM
Meets NFPA 80 & 101for Life Safety WARRANTY
YEAR
5POWER
DATASELECTABLE
FIELD
12 24
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Security Door ControlsACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM2
DISPLAY MODES
Doorarmedandlocked.15
Alarmcountdownperiodhasended, door is unlocked and alarm sounding until reset.
00
Doorunlockedandalarmisshunted(REXorBypass)
- -
DoorhasbeenopenedafterREX,BypassorAlarm.- - - -
- -
•IFCInternationalFireCode• IBCInternationalBuildingCode• NFPA101LifeSafetyCode• NFPA1UniformFireCode•CaliforniaBuildingCode
CODE COMPLIANCESPECIFICATIONS
DOOR WITH LATCH ASSEMBLYACTIVATION BY DOOR MOVEMENT
standard exit deviceno switch,no power transfer
PUSH UNTIL ALARM SOUNDS. DOOR CAN BEOPENED IN 15 SECONDS
EMLock
power supplyto �re command center
115 VAC
DOOR WITHOUT LATCH ASSEMBLYACTIVATION BY SURE EXIT® PUSH BAR
MSB550/PSB580REX bar
PUSH UNTIL ALARM SOUNDS. DOOR CAN BEOPENED IN 15 SECONDS
EMLock
power supplyto �re command center
115 VAC
power transfer hingeor loop
Electrical Specifications
Inputs
Voltage Input Autosensing12/24VDC+/-10%
Reset Input N.O.,Dry
REX Input N.O.,Dry
Trigger N.C.orN.O.,Dry
IBO/DPS IBO:N.O.,Dry DPS:N.C.
Monitoring Outputs
Alarm Output 1Amp@30VDCSPDTDry
Lock Secure Output
1Amp@30VDCSPDTDry
Mechanical Specifications
Controller 6-1/2”x4-1/2”x1-1/2”
1581DE 8-3/4”x2-1/8”x1-1/4”
1571DE / 1511DE
11”x2-3/4”x1-9/16”
1575DE / 1576DE
8-45/64”x2-1/2”x1-39/64”
APPLICATION
WWW.SDCSECURITY.COM ■ SECURITY DOOR CONTROLS
Security Door ControlsACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 3
101-DE 101-KDE
1581DEV1571DEV1511DEV
1575DEU1576DEU
HOW TO ORDER
3| SPECIFY MAGNETIC LOCK WITH INTEGRATED ACTIVATION SENSOR (SPECIFY TWO FOR PAIR OF DOORS)
1| SPECIFY MODDEL (ONE PER OPENING)
NA NFPA101,IBCandIFCCompliantFieldselectable:15or30secondexitdelay,1or2secondnuisancedelayFieldselectableautomaticormanualpower-upafteremergency release
ND UBC,CaliforniaBuildingCode,OSHPD,NFPA101,IBC&IFCCompliant 15secondfixedexitdelay,2secondnuisancedelay.FieldselectablemanualpowerupafteremergencyreleaseforCaliforniaandOSHPDcompliance
NH IBC,IFC,NFPA101Compliant30secondfixedexitdelay,2secondnuisancedelay
NC CBCCompliant15secondfixedexitdelay,2secondnuisancedelay,power up unlocked fixed
BD BOCANationalBuildingCodeCompliant15secondfixedexitdelay,1secondnuisancedelay,autoreset30secondsafterdoorclosure
BH BOCANationalBuildingCodeCompliant30secondfixedexitdelay,1secondnuisancedelay,autoreset30secondafterdoorclosure
2| SPECIFY OPERATION MODE
1511DEV Single,1650lbsholdingforce, 670/350mA@12/24VDC
1571DEV Single,1200lbsholdingforce,EnergySaver, 250/125mA@12/24VDC
1581DEV Single,650lbsholdingforce, 440/220mA@12/24VDC
Outdoor Locks1575DEU Singleoutdoormagneticlockwith
magnetic bond sensor1576DEU Singlefacedrilledoutdoormagneticlock
with magnetic bond sensor
4| SPECIFY MAGNETIC LOCK FINISH
AnodizedFinishes V Aluminum(standard) Y BlackanodizedPaintedFinishesX Darkbronzepowdercoat
5| SPECIFY MONITORING (OPTIONAL)
D Door Position Sensor: Indicatesdooropenanddoorclosed.Specifytwofordoubledoors (not available with 1581, 1575 and 1576) SPDTDry,250mA@30VDC.
B Magnetic Bond Sensor: Indicateslockedandunlocked, low holding power, tampering and obstruction between armature and magnetic core.Specify(2)fordoubledoors(1581DE SPSTonly)
1575DE-ZB Inswingmountingbracketfor1576DEU
101-1AK OutdoorresettwithLEDandaudibleannuncia-tor,2-gangoutdoorboxrequired
101-SPSN RemoteSingleGangAnnunciatorwithspeakerand80dbtone.DuplicatesExitCheckalternat-ing voice message and tone.
DEC-J 3-ganginteriorsurfacemountbox for 101-DE
SHD-J Shroudforsurfacemountbox DEC-J outdoor use
101-DE Wall mount controller with keypad con-trol and reset
101-KDE Wall mount controller with both key switch and keypad control and reset
ACCESSORIES
DEC-J101-DE,DEC-J,SHD-J101-1AK 101-SPSN
PRODUCT SKU SAMPLE: 101-DE NC 1571DEV V D
© 2016 SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
Security Door Controls
LIT-101-DE 10/16
[t] 800.413.8783 ■ 805.494.0622 ■ [f] 866.215.3138 ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
ACCESSORIES
MSB550V MechanicalREXExitbarforactivationoflocks on doors without latch assemblies
101-4AM Remotefourdoorannunciatorwithaudiblealarmmutebutton.FourtricolorLED's,2-Gang
Green-Secure Amber-EgressInitiated Red-DoorUnlocked
TCC Desktopconsoleforremotecontrolandannunciation of4-12doors
• 12Stationsmaximumwhenusing2contolpanels• Baseunit,lesspanel• Color:Blacksidesandbeigetop
Dimensions: 10-1/4" W x 4-3/4" H x 9-5/8" D
PSB560V SureExit®REXsensorbarforactivation of locks on doors without latch assemblies
MECHANICAL REX EXIT BAR
REMOTE FOUR DOOR ANNUNCIATOR MODULAR CONTROL CONSOLE
SURE EXIT® SENSE BARPUSH TO EXIT Field Applied Sign with Green Letters PUSH TO EXIT Field Applied Sign with Green Letters
SPECIFICATIONS
Actuation 1/8" total bar movement for mechanical switch actuation
Contact SPDT, 5 Amp @ 30VDC (2nd Switch Optional)
Accessories Included
PT-2U Armored Power Transfer Loop
SPECIFICATIONSActuation Pressure Sensing Technology, Tri-Failsafe
Voltage 12/24VDC Voltage Sense Input
Current 20 mA at Rest, 115 mA Active
Lock Ouput SPDT, 3 Amp @ 30VDC
Alarm Shunt/Status Output
SPDT, 3 Amp @ 30VDC
Accessories Include
10 ft. cable and connector. PT-2U Armored Power Transfer Loop
HOW TO ORDER
1| SPECIFY MODEL
2| FINISH
3| SPECIFY OPTIONS
4| SPECIFY LENGTH
MSB550V MechanicalREXBar
628AluminumAnodized(Standard)
2SPDTContactsAdd"2"for2ndmechanicalswitchfordual-fail-safe redundant operation, alarm shunt, or mon-itoingoutput.Ex:MSB550-2V
36 StandardBarLengthis36"42 Barfor42"Door.Maybefieldcut.48 Barfor48"Door.MaybefieldcutEx:MSB550V-42
HOW TO ORDER
1| SPECIFY MODEL
2| FINISH
3| SPECIFY LENGTH
PSB550V SureExit®SenseBar
628AluminumAnodized(Standard)
36 StandardBarLengthis36"42 Barfor42"Door.Maybefieldcut.48 Barfor48"Door.MaybefieldcutEx:PSB550V-42
TMTM
AccessControlSystemsUnit
BurglaryResistantElectronicLockingMechanism
4J82
CSFM3774-0324:103
AccessControlSystemsUnit
BurglaryResistantElectronicLockingMechanism
4J82
CSFM3774-0324:103
TMTM