1 taiex ped workshop - im 23782 taiex workshop on the implementation of the pressure equipment...

Post on 27-Dec-2015

228 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

1

TAIEX PED workshop - IM 23782

TAIEX Workshop on the implementation of the

Pressure Equipment Directive (PED)

Bucharest, 27 February - 1 March 2007

Non-Destructive Testing:

New Methods and Qualification of Personnel

2

TAIEX PED workshop - IM 23782

contractor:

Who has qualified your NDT personnel?

3

TAIEX PED workshop - IM 23782

Annex I chapter 3.1.3

3.1.3. Non-destructive tests

For pressure equipment, non-destructive tests of permanent joints must be carried out by suitable qualified personnel.

For pressure equipment in categories III and IV, the personnel must be approved by a third-party organization recognized by a Member State pursuant to Article 13.

qualified personnel.

4

TAIEX PED workshop - IM 23782

Certification by

third-party organisationemployer

SNT-TC-1A EN 473ISO 9712

EN 473:2006-01 Non destructive testing -

Qualification and certification of NDT personnel -

General principles

ISO 9712:2005-02 Non destructive testing -

Qualification and certification of NDT personnel

and

Technical Corrigendum 1:2006-11

Recommended Practice No.

SNT-TC-1A

1984, 1988, 1992, 1996 or

2001 Edition

5

TAIEX PED workshop - IM 23782

Certification by

third-party organisationemployer

SNT-TC-1A EN 473ISO 9712

employer maintainssystem for qualification,certification and surveillance of NDT personnel

employer uses external system for qualification, certification and surveillance of NDT personnel of a certification body

employer authorises NDT personnel

6

TAIEX PED workshop - IM 23782

Certification by

third-party organisationemployer

SNT-TC-1A EN 473ISO 9712

Adopted to companyneeds

Direct surveillance

Quite flexible

Proved independence from company interests

EU / worldwide recognised

Handsome system for SMEs

7

TAIEX PED workshop - IM 23782

EN 473 / ISO 9712

NDT methods: AT Acoustic emission

ET Eddy current

LT Leak testing

MT Magnetic testing

PT Penetrant testing

RT Radiographic testing

UT Ultrasonic testing

VT Visual testing

EN 473 Applicable for

other NDT methods

infrared thermographic testing and strain testing

8

TAIEX PED workshop - IM 23782

EN 473 / ISO 9712

Requirements:

Certification body

Comply with ISO / IEC 17024 Conformity assessment General requirements for bodies operating certification of persons

Authorised qualifying bodies

Examination centre

Employer

9

TAIEX PED workshop - IM 23782

EN 473 / ISO 9712

Requirements (cont.):

Qualification levels

Competence of level 1, 2 and 3 personnel

Responsibilities of level 1, 2 and 3 personnel

level 1: perform test acc. written practice, documentation

level 2: level 1 + select technique, design written practice

level 3: level1+2 + select method, define procedures and criteria, manage qualification examination, …

10

TAIEX PED workshop - IM 23782

EN 473 / ISO 9712

Requirements (cont.):

Certification

Training

Industrial experience

Qualification examinations

Certificates

11

TAIEX PED workshop - IM 23782

EN 473 / ISO 9712

Problems:Content of training not defined

Syllabus - IAEA-TECDOC-628 revision 1 Training guidelines in non-destructive testing techniques; 2002 edition

- ISO/TR 25107:2006-07 Non-destructive testing - Guidelines for NDT training syllabuses

No regulations for other methods e.g. such as:UT wall thickness measurement RT film evaluation

EN 473 not fully harmonised with ISO 9712

EN 473 not applied by all industrial sectors

12

TAIEX PED workshop - IM 23782

EN 473 / ISO 9712

Benefits:

Widely distributed in Europe

over 120 000 certificates

Broad acceptance

Reference in product standards

EN 13445Unfired pressure vesselsPart 5 - Inspection and Testing

13

TAIEX PED workshop - IM 23782

Annex I chapter 3.1.3

3.1.3. Non-destructive tests

For pressure equipment, non-destructive tests of permanent joints must be carried out by suitable qualified personnel.

For pressure equipment in categories III and IV, the personnel must be approved by a third-party organization recognized by a Member State pursuant to Article 13.

In Germany:

Notified by ZLS

Central Office of Safety of the German Länder

ISO / IEC 17024 + “delta”

14

TAIEX PED workshop - IM 23782

EFNDT Multilateral Recognition of NDT Personnel Certification Schemes

Certification Body seeking recognition of its system

Compliance with EFNDT Code of Practice

National NDT society being member of EFNDT or ICNDT

or Audit by EFNDT Certification Executive Committee (CEC)

EN 473

ISO 9712

ISO / IEC 17024

Accreditation by EA signatory member

or Recognition by governmental department/agency

www.efndt.org

15

TAIEX PED workshop - IM 23782

Digital Techniques Radiologywith Computer Radiography

Radiologywith Computer Radiography

Radiology with Real Time Detectors

Radiology with Real Time Detectors

16

TAIEX PED workshop - IM 23782

Image plates versus radiographic film

Much larger dynamic range

Large wall thickness differences with one “shoot”

Multiple use

Reduced exposure time

Reduced dose rate

No chemistry, no dark room

Scan time 10 sec to 120 sec

17

TAIEX PED workshop - IM 23782

Image plates versus radiographic film

EN 14784-1:2005-11 Non-destructive testingIndustrial computed radiography with storage phosphor imaging plates

Part 1: Classification of systems

EN 14784-2:2005-11 Non-destructive testingIndustrial computed radiography with storage phosphor imaging plates

Part 2: General principles for testing of metallic materials using X-rays and gamma rays

18

TAIEX PED workshop - IM 23782

Image plates

19

TAIEX PED workshop - IM 23782

Realt time detectors

Varian flat panel Detector

radiation produceslight flashes which are stored in photo diodes

output via transistors

20

TAIEX PED workshop - IM 23782

Qualification

Digital Radiology

film-less radiographic testing

multi-sectorial

Level 1

Level 2 }Qualification and certification acc.

EN 473

21

TAIEX PED workshop - IM 23782

contractor:

Who has qualified your NDT personnel?

top related