01_ eltek valere telecom products, jan 2010.pdf
Post on 03-Jun-2018
333 Views
Preview:
TRANSCRIPT
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
1/48
>
Eltek ValereTelecom Product Overview
January 2010
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
2/48
Slide 2
15/11/2010
A Full Line of DC Power Systems
Small Medium Large
> Broadest Industry Product Offering Everything from 5 amps to 10,000 amps
> Highest Performance High efficiency, high density
Minipack1U/1,6kW2U/4,8kW
Compact Systems2U/7,5kW
FP 22U/8kW
6U/8-24kW
FP 248-280kW
Scalable100-1000kW
Micropack2U/1kW
PP 5,854-550kW
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
3/48
Slide 3
15/11/2010
Leading edge Rectifier Modules
Minipack400 & 800W
FP 22000-3000W
V-Series1000-2500 W
Powerpack3ph/11000W
> Power from 250W to 11KW per module
> Designed for harsh environments
> Efficiency >96%!
Micropack250W
Powerpack3ph/5800W
Small Medium LargeC
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
4/48
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
5/48
Slide 5
15/11/2010
Smartpack More than just a controller
> Full remote control via: Ethernet using standard WEB Browser or
EltekValere Windows SW and email alertfunctionality
Modem using alarm call back and SMSalert/status report functionality
Ethernet based closed private networks usingNetwork Management Systems with SNMP
> Comprehensive Battery Management Thermal compensation Battery disconnection preventing deep discharge Multi level load shedding Charge control, current and voltage Battery life time prediction
> Hybrid solar features Generator control (cyclic charging) for reduced fuel
consumption Reduced charge current limitation when running
gen-sets Startup delay of rectifiers Logging of energy produced from PV panel,
genset and other sources
> Efficiency Management Manages system to target efficiency Rectifiers disabled based on system load Rectifiers are shuffled to maximize lifetime N+1 redundancy kept as default, but can be
removed
> Other features
Multi language menu choice Major and minor alarm trigger levels on all
monitors PLC functionality triggering of event trough
Boolean functions Battery & load fuse monitoring Mains supervision Event log (10.000 alarms and events) Interval data logging of selected monitors Average and peak values of all monitors
Detailed rectifier inventory with internal monitoring Adjustable rectifier walk-in
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
6/48
Slide 6
15/11/2010
Smartpack More than just a controller
> Additional functionality by optional CAN nodes
Smartnode RS-232/RS-485 Communication with equipmentwith proprietary protocols Modem call-back and SMS
feature with GSM modems
Battery Monitor Additional monitoring of
battery fuse, temperature,
block voltage & currentper string
Load Monitor Additional monitoring of
8 individual loadbreakers and currents
I/OMonitor Additional monitoring of 6
aux. inputs and 6 extra outputrelays
2 temperature probe inputs 2 Analogue outputs 2 tacho input readings
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
7/48
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
8/48
Slide 8
15/11/2010
CTO Configure To Order
Tailor-made systems combiningstandard building blocs
Integrated
Indoor cabinet
Outdoor cabinet
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
9/48
Slide 9
15/11/2010
CTO Configure To Order
ERPBOM
Configurator Order Office/Logistics Manufacturing site
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
10/48
Slide 10
15/11/2010
Micropack
Minipack
Flatpack2
Powerpack
Cabinets
Remote Power System
Telecom Product Families
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
11/48
Slide 11
15/11/2010
48V / 250W (241120.100)
24V / 240W (241120.200)
12V / 120W (241120.300)
Main Characteristics
> Convection-cooled (no internal fans)
> Integrated module alarm
> Wide AC range
> CAN Bus communication
150mm
88mm
2U
44mm
1U
Micropack Rectifier Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
12/48
Slide 12
15/11/2010
150 mm
44 mm
134 mm
Micropack Stand-alone
88 mm
Stand-alone Power Core Card
(241120.900)
Main Characteristics
> Single AC feed
> 1 x alarm output
> Bulk feed DC out
> DIN mounted solution
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
13/48
Slide 13
15/11/2010
Compack (241120.400)
Main Characteristics
> CAN Bus communication
> User connects via Ethernet port
> 2 x LVD operation support
> 3 x pot. free alarm contacts
> Supports CAN nodes
110 mm
70 mm
30 mm
Micropack Controller Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
14/48
Slide 14
15/11/2010
Micropack Integrated System
2 or 4 module positions
> Max 500W or 1000W
> Compack controller
> Load distribution modules, eachwith 4x plug in breaker positions
> Battery breaker module with2xBattery MCB, currentmeasurement and LVBD
> Optional Bulk-feed module
> Optional 19 bracket
Batt. dist. module241120.910
Load. dist. module241120.920
Bulk feed module241120.911
-48V -48V
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
15/48
Slide 15
15/11/2010
Micropack
Minipack
Flatpack2
Powerpack
Cabinets
Remote Power System
Telecom Product Families
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
16/48
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
17/48
Slide 17
15/11/2010
Smartpack Extended(242100.110)
Smartpack RS-232 Front(242100.111)
Smartpack GB RS-232 Front (Chinese )(242100.114)
Smartpack WEB/SNMP 6+6(242100.118)
144 mm
43 mm
1U
109 mm
Smartpack Controller
Main Characteristics> CAN Bus communication
> LCD screen and keypad
> User connects via USB
> Supports CAN nodes
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
18/48
Slide 18
15/11/2010
Minipack Integrated System 2U
> 48V/3200W Up to 4 Rectifiers
SmartPack
Max 10 MCB, (2-30A plug-in breakers)
Max 2 x 60A BB
LVBD
Optional LVLD
Bulk-feed options
> 48V/4800W Up to 6 Rectifiers
SmartPack
Max 8 MCB, (2-30A plug-in breakers)
Max 2 x 100A BB
LVBD
Optional LVLD
Bulk-feed options
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
19/48
Slide 1915/11/2010
Compack (241120.400)
Main Characteristics
> CAN Bus communication
> User connects via Ethernet port
> 2 x LVD operation support
> 3 x pot. free alarm contacts
> Supports CAN nodes
110 mm
70 mm
30 mm
Minipack 1U Controller Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
20/48
Slide 2015/11/2010
Minipack Integrated System 1U
> Bulk feed Pure DC power supply AC in 48V DC out, no
DC distribution
Optional controller, Compack, for remotemonitoring
> DC Distribution Integrated DC distribution:
- 6 x load fuses, (max. 10A)- 2 x battery breakers, plug-in type, max 30A- Low volt disconnection- Fuse monitoring
Battery management included temp.compensated charging, automatic or manualbattery testing, low volt disconnection, etc.
Controller (Compack) for full remotemonitoring via WEB and traditional alarmcontacts
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
21/48
Slide 2115/11/2010
Micropack
Minipack
Flatpack2
Powerpack
Cabinets
Remote Power System
Telecom Product Families
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
22/48
Slide 2215/11/2010
Main Characteristics
>Fan cooled
> Rear edge-connect
> Wide AC range
3 2 7 m m
41,5 mm
1U
1 0 9 m m
Flatpack2 Rectifiers Standard range
48V / 2000W (241115.100)
48V / 2000W B-F (241115.120)
24V / 2000W WOR (241115.250)
48V / 3000W (241119.100)
MaxEfficiencyZone
88
90
92
94
0 400 800 1200 1600 2000Pout(W)
E f f . (
% )
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
23/48
Slide 2315/11/2010
Main Characteristics
> >96% efficiency !!> Only 1 FAN (less noise)
> 100% plug compatible with standard range
Flatpack2 Rectifiers HE range
48V / 2000W (241115.105)
48V / 3000W (241119.105)
24V / 1800W (241115.205)
96% 95%
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
24/48
Slide 2415/11/2010
Features
> Maximum Power Point Tracking
> Galvanic isolation
> Supported by current Smartpacks
48V / 1500W (241115.650)
Main Characteristics
> Uses same PR as FP2 rectifier
> Input voltage (tolerance) : 170 265 VDCTypical input feed is from one string of between 4 to 6 solar
panels
Flatpack2 HE Solar Solar Charger
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
25/48
Slide 2515/11/2010
Smartpack
Load
Gen set
Solar
Solar
Batteries
Same modular philosophy as for AC/DC
Common Smartpack control system
Galvanic isolation between panels andtelecom equipment improves immunity tolightning transients
HE technology, 96% efficiency
Maximum Power Point Tracking utilizesclose to 100% of available solar power
CAN bus
I/O* Unit
Fuel tank
~Mains
BatteryMonitoring*
*optional
RemoteMonitoring*
Flatpack2 Solar Hybrid concept
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
26/48
Slide 2615/11/2010
Flatpack2 Stand-alone box - DNV
Part number : M20101.000
Suit most Std and HE Flatpack2
rectifiers (see datasheet for details)
Main Characteristics
> DNV Approved
> In-Built alarm monitoring
> Can work in parallel
> CAN Bus communication
Rear view
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
27/48
Slide 2715/11/2010
Smartpack Extended(242100.110)
Smartpack RS-232 Front(242100.111)
Smartpack GB RS-232 Front (Chinese )(242100.114)
Smartpack WEB/SNMP 6+6(242100.118)
144 mm
43 mm
1U
109 mm
Smartpack Controller
Main Characteristics> CAN Bus communication
> LCD screen and keypad
> User connects via USB
> Supports CAN nodes
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
28/48
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
29/48
Slide 2915/11/2010
Includes (up to) :
1U Distribution + 1 PR
8000W (166A@48V) Smartpack
2 x 100A Battery breakers
6 x 260A Load breakers
2 x LVD (150A)
5 kg (excl. rectifiers)
Flatpack2 Small Integrated System
FP2 2kW only
Figure shown is an 8kW system with std 2kW rectifiers
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
30/48
Slide 3015/11/2010
2kW rectifier : Up to 32kW
3kW rectifier : Up to 24kW
4U Distribution + 1-4 PR Smartpack
6 x 100A (3 x 200A) BB
21 x 2125A Load breakers*
2 x LVD (up to 600A)* Check datasheet for other available combinations
Up to 10 kg (excl. rectifiers)
Includes (up to) :
Flatpack2 Medium Integrated System
2kW and 3kW options
Figure shown is a 16kW system with std 2kW rectifiers
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
31/48
Slide 3115/11/2010
2kW rectifier : Up to 96 kW
3kW rectifier : Up to 108 kW
IFC Cabinet : 2000 x 600 x 600 mm
Input 230V/400V 3-phase
2 x Battery & 6 x Load Fuse options
Secondary 30 x MCB dist. option
Flatpack2 IFC Large Power
2kW and 3Kw options
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
32/48
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
33/48
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
34/48
Slide 3415/11/2010
Main Characteristics
> True 3 Phase rectifier
> Up to 11kW output
> Basic controller built-in
> Models for different AC inputs
> CAN Bus communication
> Not hot-swappable
500 mm
585 mm
Powerpack Rectifiers
Models
11kW 48V 480VAC (241246.000) *
* Derates to 9.6kW with 400VAC input
11kW 48V 208VAC (241246.100)
2U
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
35/48
Slide 3515/11/2010
Smartpack Extended(242100.110)
Smartpack RS-232 Front(242100.111)
Smartpack GB RS-232 Front (Chinese )(242100.114)
Smartpack WEB/SNMP 6+6(242100.118)
144 mm
43 mm
1U
109 mm
Smartpack Controller
Main Characteristics> CAN Bus communication
> LCD screen and keypad
> User connects via USB
> Supports CAN nodes
Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
36/48
Slide 3615/11/2010
Powerpack 5,8kW System Solution
Main Characteristics
> 2000 x 600 x 600 mm
> Up to 20 Rectifiers per cabinet
> Bulk-Feed or integrated distribution
> Top or Bottom Entry
> Maximum 116kW per cabinet
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
37/48
Slide 3715/11/2010
Powerpack 11kW System solution
Main Characteristics
> 2000 x 600 x 600 mm
> Up to 10 Stacked Rectifiers
> Bulk-Feed or integrated distribution
> Top or Bottom Entry
> Maximum 2300 Amps per bay
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
38/48
Slide 3815/11/2010
Micropack
Minipack
Flatpack2
Powerpack
Cabinets
Remote Power System
Telecom Product Families
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
39/48
Slide 3915/11/2010
Main Characteristics
> Cost-effective cabinet
> Steel construction
> 1.2 Tonn weight capacity
> Typically Top Entry
> Some sizes have Flatpacked
option (assemble locally)
Current Range
H x W x D (mm)
700 x 600 x 400
1000 x 600 x 400
1200 x 600 x 600
1500 x 600 x 600 *1800 x 600 x 400 *
1800 x 600 x 600 *
1800 x 600 x 400
2000 x 600 x 400
2000 x 600 x 600 *
* Available in Silver finish also
Integrated Frame Cabinet (IFC)
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
40/48
Slide 4015/11/2010
15U Type 2 Fan/filter (237143)
15U Type 2 T20 AC (250661)
Main Characteristics
> Common body with different doortype for Fan/filter or Air Conditioner
> 19 mounting only
> 15U of mounting space *Lower 3U typically for AC Distribution
> Wall, Floor or Pole mount kits
Type 2 Outdoor cabinet
888 mm
527 mm
586 mm
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
41/48
Slide 4115/11/2010
Main Characteristics
> Single skin, insulated
> Select door for cooling option
1 Fan/filter 2 Fan /Filter
Air Conditioner
HEX
> Height 1.5 or 1.8m
> Foot print 700 (W) x 760 (D) mm +Cooling option depth
Type 3 Outdoor cabinet
Figure shown is 2 Fan/Filter option
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
42/48
Slide 4215/11/2010
Micropack
Minipack
Flatpack2
Powerpack
Cabinets
Remote Power System
Telecom Product Families
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
43/48
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
44/48
Slide 4415/11/2010
DC / DC Converter
> Converts -48VDC to 190VDC
> To achieve 380VDC potential, apositive and negative output
from a pair are connected toEarth
(Refer to datasheet for specifications)
DC-DC Converter module Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
45/48
Slide 4515/11/2010
Output Channels
> Provides 380VDC output, limitedto 100W.
> Provides earth leakage, surge
and short circuit protection.
(Refer to datasheet for specifications)
VA Limiter module Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
46/48
Slide 4615/11/2010
Remote End Converter
> Converts DC input to -48VDC.
> Input voltage and output powerdepend on the characteristics of
the twist pair circuit.
Typicaldistance :up to 10 km
(Refer to datasheet for specifications)
Remote End module Acronyms
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
47/48
-
8/11/2019 01_ Eltek Valere Telecom Products, Jan 2010.pdf
48/48
Slide 4815/11/2010
Vision
THE GREATEST POWERIN THE INDUSTRY