schumacher...po w e r unt i so l u ot i n s s u b m e r s b l i e & d ry one schumacher way,...

Post on 23-Jan-2021

0 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Power Unit SolUtionS SUbmerSible & dry

One Schumacher Way, Denver, IA 50622 (800) 779–LIFT (5438)

fax (319) 406–1270

Elevators@SchumacherElevator.comwww.SchumacherElevator.com

SchumAchEr

Advantages Ride not affected by changes in

load or temperature

Reduces motor run time

Eliminates overheating issues

Up to 30% energy savings

No seasonal adjustments

Wide range of application from residential to passenger to freight elevators

Options Electronic emergency lowering device

Hand pump

Pressure switch

Shut– off valve

Power Unit SolUtionS SUbmerSible & dry

SchumAchEr ELEvATOr cOmpAny IS ThE nOrTh AmErIcAn dISTrIbuTOr OF buchEr hydrAuLIcS ELEvATOr prOducTS.

valve Size Flow range

viscosity range

max Oil Temp

[oF]

max Operating pressure

Static pressure range

connectionsZ, T, p

Test–connections

Z1, Z2, Z3

Weight [lb] L x W x h [in]

LrV

–1hi

gher

Pre

ssur

e

175–1 4–66 20–500 158o 870 150*–653 1”NPT G 1/4 17.6 7.72 x 8.19 x 12.8

350–1 40–130 20–500 158o 870 150*–653 1.5”NPT G 1/4 24.3 8.5 x 19 x 14

700–1 105–260 20–500 158o 870 180*–6532”NPT

2.5”NPT 2”NPT

G 1/4

G 1/4 G 3/8

49.6 11.7 x 8.86 x 16.9

LrV

–1 P

mLo

wer

Pre

ssur

e 350–1 PM 40–130 20–300 158o 580 70*–419 1.5”NPT G 1/4 24.3 8.5 x 8.19 x 14

700–1 PM 105–260 20–300 158o 580 80*–4192”NPT

2.5”NPT2”NPT

G 1/4

G 1/4

G 3/8

49.6 11.7 x 8.86 x 16.9

* depending on flow and viscosity

Due to its closed loop operation, the Schumacher hydraulic power unit (with Bucher hydraulics valve) supplies consistent operation regardless of load and temperature. A stepless, linear travel profile is accomplished by utilizing a proportional solenoid. The solenoid voltage is adjusted with the aid of a flow sensor to guarantee a consistent ride with minimal leveling. Consequently, motor run times are reduced by as much as 30%, saving power and creating an environmentally friendly product. Bucher valves also reduce the need for heating and cooling systems, which are required by most other hydraulic systems. Schumacher power units utilizing a Bucher hydraulics electronic valve offer optimum assurance that elevators are

capable of handling high-traffic applications.

SEC–0913

LEED Compliant

hydrAuLIc pOWEr unIT FEATurES:Power units tested and pre–programmed prior to shipment

constant speed in up & down directions, comes standard

Inspection speed adjustable from 20%–80% of contract speed

Combination power unit/controller packages available

Easily interfaced with all brands of controllers

top related