Обзорный каталог brinkmann pumps -2017
Post on 10-Jan-2017
54 Views
Preview:
TRANSCRIPT
-
2017
www.brinkmannpumps.com
COOLING, LUBRICATING, CHIP HANDLING,PRESSURE BOOSTING, FLUSHING, MAINTAINING TEMPERATURES ...
COOLANT PUMPSMAIN CATALOG
-
Content
1Subject to alteration Edition 08/16
Recommendations to choose Coolant Pumps Technical Information: Electrical, Mechanical and Hydraulic Features Control / Regulation
Immersion Pumps Semi-open impellers TB | TA | TE | STE | STA Standard coolant pumps 6 ... 1300 GPM 6 ... 300 Feet
Quick Suctioning Immersion Pumps Axial/semi-open impellers with BRINKMANNs Suction De-aeration System Inflated fluids / slurping TL | TAL | STL | SAL 10 ... 660 GPM 6 ... 300 Feet
Quick Suctioning Immersion Pumps Axial/semi-open impellers with BRINKMANNs Suction De-aeration System Aerated grinding oils and coolants / slurping TGL | SGL 12 ... 640 GPM 15 ... 300 Feet
Suction Immersion Pumps Axial/semi-open impellers TAS | STS Vacuum filter 12 ... 550 GPM 6 ... 200 Feet
Horizontal End-Suction Pumps Axial/semi-open impellers SBA | SBA-V | SBG | SBG-V | SBM Coolant Lubricants / cutting oils, increased chip load 6 ... 600 GPM 15 ... 200 Feet
Quick Suctioning Immersion Pumps Axial/semi-open impellers with BRINKMANNs Suction De-aeration System Aerated coolants / slurping, heavy chip loads SFL | SBF 12 ... 650 GPM 6 ... 150 Feet
Cutter Pumps Axial/semi-open impellers with cutting units Large chips SFC | SXC | SPC | SBC 12 ... 375 GPM 12 ... 160 Feet
Free-Flow Immersion Pumps Semi-open impellers SFT | BFT Large chips 25 ... 750 GPM 6 ... 100 Feet
Immersion Pumps Peripheral impellers TS High pressure in compact units 2.5 ... 20 GPM 15 ... 290 Feet
Immersion Pumps Closed impellers Pressure Boosting Pumps High pressure / no long chips (S)TC | (S)TH | FH 2.5 ... 170 GPM 30 ... 810 Feet
Immersion Pumps in Plastics Semi-open impellers KTF Industrial water circuits 2.5 ... 110 GPM 6 ... 145 Feet
Miniature Centrifugal Pumps Open/peripheral impellers Suction Pumps Suctioning / circulating KC | SB 2.5 ... 16 GPM 6 ... 175 Feet
Miniature Centrifugal Pumps Peripheral/semi-open impellers Immersion Pumps Maintaining temperatures BMK | TB-M 2 ... 27 GPM 6 ... 240 Feet
High Pressure Immersion Pumps Screw spindles BFS | TFS | FFS High pressure 1 ... 232 GPM 145 ... 2175 PSI
Terms and Conditions Questionnaire
60 Hz
-
2 Subject to alterationEdition 08/16
Recommendations to choose Coolant Pumps
l usable m please ask before making a selection
60 Hz
Series
Application Medium Pollution Amountof
air inthe
fluid
Perfor-mance
bo
rin
g
saw
ing
mill
ing
turn
ing
gri
nd
ing
ero
din
g
circ
ula
tin
g
tem
per
ing
coo
ling
was
hin
g
emu
lsio
ns
coo
lan
ts/l
ub
rica
nts
gri
nd
ing
oils
ther
mal
oils
die
lect
ric
ind
ust
rial
wat
er
de-
ion
ized
wat
er
lees
/ s
olv
ents
coar
se
med
ium
few
no
rmal
incr
ease
d
lifti
ng
was
hin
g
pre
ssu
rin
g
TA40 ... 80 / TB16 ... 100 l l l l l m l l l l m m m l l l l lTA160 ... 600 l l l l l m l m m m l l l l l m m l l l l l l lTE/STE141 ... 146 l l l l l m l m m m l l l m l m m l l l l l lTA/STA301 ... 306 l l l l l m l m m m l l l l l m m l l l l l l lTA200 ... STA430 l l l l l m l m m m l l l l l m m l l l l l l lSTA401 ... 407 l l l l l m l m m m l l l l l m m l l l l l l lSTA601 ... 607 l l l l l m l m m m l l l l l m m l l l l l l lSTA630 ... 1130 l l l l l m l m m m l l l l l m m l l l l l l lSTA901 ... 904 l l l l l m l m m m l l l l l m m l l l l l l lSTA1001 ... 4500 l l l l l m l m m m l l l l l m m l l l l l l l
TL50 ... SAL430 l l l l l m l m m m l l l m l m m l l l l l l l lTL/STL141 ... 146 l l l l l m l m m m l l l m l m m l l l l l l lTAL/SAL301 ... 607 l l l l l m l m m m l l l m l m m l l l l l l l lSAL630 ... 2500 l l l l l m l m m m l l l m l m m l l l l l l l lTGL/SGL331 ... 2200 l l l l l m l m m m l l l m l m m l l l l l l l l
TAS301 ... 601 l l l l l m l l l l l l m m l l l l l l lSTS1001... 2000 l l l l l m l l l l l l m m l l l l l l l
SBA141S ... 2000S (V) l l l l l m l m m m l l l m l m l l l l l lSBG501S ... 1700S (V) l l l l l m l m m m l l l m l m l l l l l l lSBM140S ... 450S l l l l l m l m m m l l l m m m l l l l
SFL650 ... 2350 l l l l l m l m m l l m m m m l l l l l l lSBF550S ... 1850S l l l l l m l m m l l m m m l l l l l lSFC820 ... 2320 l l l l l m l m m l l m m m l l l l l lSXC2824S l l l l l l m m l l l l l lSPC820S l l l l l l m m l l l lSBC820S ... 1820S l l l l l m l m m m m m m m m l l l l l l l l
SFT450 ... 1400 l l l l l m l m l l l l l m m l l l l lSFT1100-4 l l l l l m l m l l l l l m m l l l l lSFT1554-C ... 3554 l l l l l m l m l l l l l m m l l l l lBFT750S ... 1250S l l l l l m l m l l l l l m m l l l l l
TS12 ... 24 l l l l l m l m m m l l l l l m m m l l l l
(S)TC25 ... 160 l l l l m m l m m l l l l l m m m l l l l(S)TH2 ... 17 l l l l m m l m m m l l l l l m m m l l l l lFH2 ... 17 l l l l m m m m m l l l l l m m m l l l l l(S)TC260 ... 460 l l l l m m l m m m l l l l l m m m l l l l l
KTF61 ... 303 m l m l l m m m m m l l l l l
KC60S m m m m m l m m m m l m m m m m l l l lSB20S ... 60S l l l l m m l m m m l l l m m m m m m l l l
BMK3 ... BMK4 m l l m m l m l m l m m m l l l lTB40-M ... 100M l l m l l m m m m l l l l
BFS1 ... TFS6 l l l l m l l l m l l l l
-
3Subject to alteration
Technical Information
Edition 08/16
Electrical Features
CE Motors acc. to EN 60034-1
Grade of protection IP55 Type of insulation F Number of poles 2 Efficiencies EN60034-30,IE31HP(0.75kW)
InaccordancewithDINEN60034-1,Zone A,andpermanentoperation,thevoltagetoleranceis5%andthefrequencytoleranceis2%.
available notavailable
Othervoltagesuponrequest.
Pole changing motors are nonstandard motors. Foroperationon60Hz,aswellasthechoiceofthecorrespondingmotorwinding,themanufacturerwillalsoadaptthehydraulics, e. g. with smaller impellers or dummy stages. Forspecialdemands,versionsforusewithastandardizedvoltage50Hzand60Hz(Transformerusage)arepossibleafterconsulting withthecompany,Forexample:3x400V,5%,5060Hz.
60 Hz 208230 V 460 V
460 V 460 V
up to 8.4 HP (6.3 kW) Standard 9.2 20.1 HP (6.9 15 kW) Standard 25 HP and higher (22 kW) Standard
Availableasaspecialdesign,e.g.:
200 V 200 V 220 V
380 V 400 V 415 V 440 V 480 V 500 V 575 V
50 Hz 60 Hz
Comparison of motor efficiency classes worldwide
Efficiency Class Europe North America,Australia,
New Zealand
China
Super premium efficiency IE4 Grade 1
Premium efficiency IE3 NEMA Premium* Grade 2
High efficiency IE2 EPAct Grade 3
IE=InternationalEfficiency* Standard for all pump motors ( 1 HP) delivered from our US facility.
Motors of 10 HP (7.5 kW) and larger
Motordesignavailablefor / -starting.
/ -startingisnotrequiredforcentrifugalpumps. Screw-spindle pumps for / -starting must be started without pressure.Soft-startingdevicesareanalternativeto / -starting.
Motor cycle time
Motorsless4HP(3kW) up to 200 times per hour.
Motorsfrom4HP(3kW)to5.4HP(4kW) up to 40 times per hour.
Motorsfrom6.7HP(5kW)to12.1HP(9kW) up to 20 times per hour.
Motors14.7HP(11kW)andlarger up to 15 times per hour.
Higheron/offcyclingfrequenciesareavailableuponrequest.
-
4 Subject to alteration
Technical Information
Edition 08/16
Electrical Features
CC311B
International Regulations, Brinkmann motors
ApprovedbyULwithULRecognizedComponent
MarkforUSAacc.toUL1004-1andforCanadaacc.
toCSAC22.2No.100-14(UL-FileE233349)
BrinkmannMotorsupto20.1HP(15kW),60Hz,anduptomax.600VareavailablewithULRecognizedComponentMark approvalasspecialdesigns.
Brinkmannmotorsrangingfrom2.3kW(3.1HP)to13kW(17.4HP),50Hz,are availablewiththeChinaEnergyLabelGB18613-2012,Grade2uponrequest.
ComplianceCertificationnumberCC311B
accordingto10C.F.R.431
(NEMA PREMIUM EFFICIENCY)
Brinkmannmotorsrangingfrom1HP (0.86kW)to20.1HP(15kW,60Hz),areavailablewithNEMAPREMIUMMG1uponrequest.
Brinkmann MotorsOptions
50 Hz 60 Hz
200 V 380 V 400 V 415 V 500 V 200 V 220 V
380 V 400V 440 V 460 V 230 V 460 V
480 V 230 V 480 V
575 V
available notavailablem uponrequestAdditionalcountry-specific approvalsuponrequest.
UL/CSA
CEL (Grade 2) 2.3 kW
NEMA PREMIUM MG 1
1 HP( 0.86 kW)
1 8.4 HP
(0.86 6.3 kW) Stan-dard m
4.6 20.1 HP
(3.45 15 kW)
/ 1 20.1 HP
(0.86 15 kW) m
Stan-dard
m
International Regulations, Standard motors
Uponrequest.Dependingonactualmotorratingandsizing(Power/Motorefficiencyclass)deviationsinpumpandmotor configurationsarepossible.Anoverviewofpumpsbuiltwithstandardmotorscanbefoundonourwebsite.
Current / Rated current
Thecurrent(Icatalog)statedatthenameplatesisusedforthesizingofelectroniccomponents.
Motor