ammonium removal using anammox process

2
Funded by: www.uni-due.de/zwu/iwatec Ammonium Removal using Anaerobic Ammonium Oxidation (Anammox Process) M.El-Qelish 1,2  , F. El-Gohary 1 , B. Teichgräber 3 , P. Volmerg 2 , T. Gehrke 2 , M. Denecke 2 1: National Research Center, Water Pollution Research Department, Cairo, Egypt 2: University of Duisburg-Essen, Municipal Wat er and Waste Management, Essen Germany 3. Head of Technical Service Division, Emschergenossenschaft & Lippeverband, Essen, Germany. Introduction Nitrogen removal from ammonium-rich wastewater has attracted increased attentio n due to the serious water pollution consequences such as eutrophication of water bodies (Burkholder et al., 2007; Istvanovics, 2009; Withers et al., 2011). The most widely used ammonium removal technology around the world was the conventional nitrification-denitrification process. However, the application of the conventional process was limited by high operational cost and the external addition of organic matter for the denitrification step (Jetten et al., 1999). Anaerobic ammonium oxidation (anammox) accomplishes direct conversion of ammonium to nitrogen gas. Anaerobic ammonium oxidation (ANAMMO X) is a biological reaction in which the anaerobic ammonium oxidation bacteria (AnAOB) combine nitrite and ammonium to form nitrogen gas using nitrite as electron acceptor under anoxic condition (Strous et al., 1998; Jetten et al., 1999). The ANAMMOX process has the following advantages as compared to conventional nitrification  denitrification processes: it does not require the addition of external carbon, less sludge production and low energy consumption (Tang et al., 2011; van der Star et al., 2007 ). Methods 1. Exper imen tal set -up: A lab-scale experimental set-up was designed and manufactured. A schematic diagram is shown in Figure-1. The system was fed continuously with synthetic waste water prepared accordi ng to (Ni et al., 2010). For the start up of the Fixed Bed Reactor (FBR), granular sludge from Kamen wastewater treatment plant (Figure-2) was used. The characteristics of the sludge are presented in Table-1. To avoid wash out of the sludge, a layer of activated carbon was used. To confirm the presence of the anammox bacteria in the inoculum sludge, fluorescence In-Situ Hybridization (FISH) test was used (Fig.3). 2. The performance of the s ystem was moni tored by implemen ting an intensive chemical analysis program of the influent and effluent of the FBR. The analyses covered ammonia, nitrite, nitrate and chemical oxygen demand. 3. Qualitati ve and quantita tive analysis of the g as produced was carried out (Table 2). 4. T raining on full sca le Anammox pilot pla nt in Kamen (Fig . 3) Conclusions and outlook The FBR anammox reactor can successfully treat low strength ammonia rich wastewater through the completely autotrophic nitrogen removal process. Using low activity anammox inoculum from full scale pilot plant treating sludge liquor (58.6 % removal efficiency), the inoculated sludge in FBR gave removal efficiency of 90.2%, which was higher than that of the inoculum sludge. FISH analysis confirmed the stable presence of anammox bacteria Results Anammox process The FBR was operated for 60 days at ammonia loading rate 0.13 kg/m 3 /day and hydraulic retention time of 1.36 days. Results of the feed and the treated effluent are summarized in Tab les 3 &4. Available data indicat es that the efficiency of the anammox process for ammonia removal reached up to 90.2±7.8% as shown in figure (4). Nitrite, nitrate and COD removal values were 89.0±5.6%, 52.0±11.5 and 68.6±10.9, respectively as shown in (figures 5, 6, and 7 and table 4).  Contact: Mohamed El-Qelish, National Research Center, Water Pollution Research Department, [email protected] References Burkhold er, J.M., Tomasko, D .A., Touchette, B.W ., 2007. Seagrasses and eutrop hication. J. Exp. Marine Biol. Ecol. 350, 46e72. Istvanovics, V., 2009. Eutrophicatio n of lakes and reservoirs. Encyclopedia of Inland Waters, 157-165. Jetten, M.S.M., Strous, M., Katinka, T., van de Pas-Schoonen, K., Schalk, J., van Dongen, U.G.J.M., van de Graaf , A.A., Logemann, S., Muyzer, G., van Loosdrecht, M.C.M., Kuenen, J.G., 1999. The anaerobic oxidation of ammonium. FEMS Microbiol. Rev . 22, 421-437. van der Star, W.R.L., Abma, W.R., Bolmmers, D., Mulder, J., Tokutomi, T., Strous, M., Picioreanu, C., van Loosdrecht, M.C.M., 2007. Startup of reactors for anoxic ammonium oxidation: experiences from the first full-scale anammox reactor in Rotter dam. Water Res. 41, 4149-4163. Table (1): Sludge analysis Table (2): Gas analysis of FBR Figure (2): FISH of the sludge from Kamen Figure (1): Experimental set up of the anammox process Figure (3): Wastewater treatment plant in Kamen 0,00 20,00 40,00 60,00 80,00 100,00 120,00 10 15 20 25 30 35 40 45 50    A    m    m    o    n    i    a    c    o    n    c    e    n    t    r    a    t    i    o    n     (    m    g     /     l     ) Time (days) Influent Ammonia concentration (mg/l) Effluent Ammonia concentration (mg/l) Figure (4): Ammonia removal efficiency 0,00 20,00 40,00 60,00 80,00 100,00 120,00 140,00 160,00 10 15 20 25 30 35 40 45 50    N    i    t    r    i    t    e    c    o    n    c    e    n    t    r    a    t    i    o    n     (    m    g     /     l     ) Time (days) Infl uent Nitr ite conce ntrat ion (mg/ l) Effl uent Nit rite con centr ation (mg/l) Figure (6): Nitrite removal efficiency 0 50 100 150 200 250 300 350 400 10 15 20 25 30 35 40 45 50    C    O    D    c    o    n    c    e    n    t    r    a    t    i    o    n     (    m    g     /     l     ) Time (days) COD influent (mg/l) COD effluent (mg/l) Figure (5): COD removal efficiency 0 5 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 50    N    i    t    r    a    t    e    c    o    n    c    e    n    t    r    a    t    i    o    n     (    m    g     /     l     ) Time (days) Infle nt Nitra te conc entra tion (mg /l) Efflu ent Nitr ate conc entra tion (mg /l) Figure (7): Nitrate removal efficiency Parameter Unit Average Maximum Minimum pH - 7.8±0.5 8.2 7. 6 Ammonia mgN/l 96.5±9.4 11 2 74.6 Nitrite mgN/l 111.35±19.1 148 88.8 Nitrate mgN/l 32.66±4.5 39.1 24 COD mgO2/l 183.3±58.1 362 102 Parameter Unit Sludge from Kamen SV ml/l 300 MLSS (105° C) g/l 21.9 MLSS (550° C) g/l 18.46 VSS/TSS % 84.3 SVI - 13.6 Parameter Unit Fixed Bed Reactor CH 4  % 3.6 CO 2  % 1.0 O2 % 7.2 H 2 S % 0 Bal % 88.2 Table (3): Chemical analysis of the i nfluent synthetic wastewater Parameter Average % Maximum % Minimum % Ammonia 90.2±7.8 99.7 72.2 Nitrite 89.0±5.6 94.5 71.6 Nitrate 52.0±11.5 71.9 33.1 COD 68.6±10.9 84.3 47.3 Table (4): Average, maximum and minimum removal efficiency of ammonia

Upload: sudarno-utomo

Post on 06-Jul-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ammonium Removal Using ANAMMOX Process

8/17/2019 Ammonium Removal Using ANAMMOX Process

http://slidepdf.com/reader/full/ammonium-removal-using-anammox-process 1/1

Funded by:

www.uni-due.de/zwu/iwatec

Ammonium Removal using Anaerobic Ammonium Oxidation

(Anammox Process)M.El-Qelish1,2 , F. El-Gohary1, B. Teichgräber3, P. Volmerg2, T. Gehrke2, M. Denecke2 

1: National Research Center, Water Pollution Research Department, Cairo, Egypt

2: University of Duisburg-Essen, Municipal Water and Waste Management, Essen Germany

3. Head of Technical Service Division, Emschergenossenschaft & Lippeverband, Essen, Germany.

Introduction 

Nitrogen removal from ammonium-rich wastewater has attracted increased

attention due to the serious water pollution consequences such as eutrophication of

water bodies (Burkholder et al., 2007; Istvanovics, 2009; Withers et al., 2011). The

most widely used ammonium removal technology around the world was the

conventional nitrification-denitrification process. However, the application of theconventional process was limited by high operational cost and the external addition

of organic matter for the denitrification step (Jetten et al., 1999). Anaerobic

ammonium oxidation (anammox) accomplishes direct conversion of ammonium to

nitrogen gas. Anaerobic ammonium oxidation (ANAMMOX) is a biological reaction in

which the anaerobic ammonium oxidation bacteria (AnAOB) combine nitrite and

ammonium to form nitrogen gas using nitrite as electron acceptor under anoxic

condition (Strous et al., 1998; Jetten et al., 1999). The ANAMMOX process has the

following advantages as compared to conventional nitrification –denitrification

processes: it does not require the addition of external carbon, less sludge

production and low energy consumption (Tang et al., 2011; van der Star et al.,

2007 ). 

Methods

1. Experimental set-up: A lab-scale experimental set-up was

designed and manufactured. A schematic diagram is shown in

Figure-1. The system was fed continuously with synthetic waste

water prepared according to (Ni et al., 2010). For the start up of

the Fixed Bed Reactor (FBR), granular sludge from Kamen

wastewater treatment plant (Figure-2) was used. The

characteristics of the sludge are presented in Table-1. To avoid

wash out of the sludge, a layer of activated carbon was used. To

confirm the presence of the anammox bacteria in the inoculum

sludge, fluorescence In-Situ Hybridization (FISH) test was used

(Fig.3).

2. The performance of the system was monitored by implementing

an intensive chemical analysis program of the influent and

effluent of the FBR. The analyses covered ammonia, nitrite,

nitrate and chemical oxygen demand.

3. Qualitative and quantitative analysis of the gas produced was

carried out (Table 2).

4. Training on full scale Anammox pilot plant in Kamen (Fig. 3)

Conclusions and outlookThe FBR anammox reactor can successfully treat low strength ammonia rich wastewater through the completely autotrophic nitrogen removal process.

Using low activity anammox inoculum from full scale pilot plant treating sludge liquor (58.6 % removal efficiency), the inoculated sludge in FBR gave

removal efficiency of 90.2%, which was higher than that of the inoculum sludge. FISH analysis confirmed the stable presence of anammox bacteria

Results

Anammox process

The FBR was operated for 60 days at ammonia loading rate 0.13

kg/m3/day and hydraulic retention time of 1.36 days. Results of the

feed and the treated effluent are summarized in Tables 3 &4.

Available data indicates that the efficiency of the anammox process for

ammonia removal reached up to 90.2±7.8% as shown in figure (4).

Nitrite, nitrate and COD removal values were 89.0±5.6%, 52.0±11.5 and

68.6±10.9, respectively as shown in (figures 5, 6, and 7 and table 4). 

Contact: Mohamed El-Qelish, National Research Center, Water Pollution Research Department, [email protected]

References

Burkholder, J.M., Tomasko, D.A., Touchette, B.W., 2007. Seagrasses and eutrophication. J. Exp. Marine Biol. Ecol. 350, 46e72.

Istvanovics, V., 2009. Eutrophication of lakes and reservoirs. Encyclopedia of Inland Waters, 157-165.

Jetten, M.S.M., Strous, M., Katinka, T., van de Pas-Schoonen, K., Schalk, J., van Dongen, U.G.J.M., van de Graaf, A.A., Logemann, S., Muyzer, G., van

Loosdrecht, M.C.M., Kuenen, J.G., 1999. The anaerobic oxidation of ammonium. FEMS Microbiol. Rev. 22, 421-437.

van der Star, W.R.L., Abma, W.R., Bolmmers, D., Mulder, J., Tokutomi, T., Strous, M., Picioreanu, C., van Loosdrecht, M.C.M., 2007. Startup of reactors for

anoxic ammonium oxidation: experiences from the first full-scale anammox reactor in Rotterdam. Water Res. 41, 4149-4163.

Table (1): Sludge analysis Table (2): Gas analysis of FBR

Figure (2): FISH of the sludge from KamenFigure (1): Experimental set up of the anammox process

Figure (3): Wastewater treatment plant in Kamen

0,00

20,00

40,00

60,00

80,00

100,00

120,00

10 15 20 25 30 35 40 45 50

   A   m   m   o   n   i   a   c   o   n   c   e   n   t   r   a   t   i   o   n    (   m   g    /    l    )

Time (days)

Influent Ammonia concentration (mg/l) Effluent Ammonia concentration (mg/l)

Figure (4): Ammonia removal efficiency

0,00

20,00

40,00

60,00

80,00

100,00

120,00

140,00

160,00

10 15 20 25 30 35 40 45 50

   N   i   t   r   i   t   e   c   o   n   c   e   n   t   r   a   t   i   o   n    (   m   g    /    l    )

Time (days)

Influent Nitrite concentration (mg/l) Effluent Nitrite concentration (mg/l)

Figure (6): Nitrite removal efficiency

0

50

100

150

200

250

300

350

400

10 15 20 25 30 35 40 45 50

   C   O   D   c   o   n   c   e   n   t   r   a   t   i   o   n    (   m   g    /    l    )

Time (days)

COD influent (mg/l) COD effluent (mg/l)

Figure (5): COD removal efficiency

0

5

10

15

20

25

30

35

40

45

10 15 20 25 30 35 40 45 50

   N   i   t   r   a   t   e   c   o   n   c   e   n   t   r   a   t   i   o   n    (   m   g    /    l    )

Time (days)

Inflent Nitrate concentration (mg/l) Effluent Nitrate concentration (mg/l)

Figure (7): Nitrate removal efficiency

Parameter Unit Average Maximum Minimum

pH - 7.8±0.5 8.2 7. 6

Ammonia mgN/l 96.5±9.4 11 2 74.6

Nitrite mgN/l 111.35±19.1 148 88.8

Nitrate mgN/l 32.66±4.5 39.1 24

COD mgO2/l 183.3±58.1 362 102

Parameter Unit

Sludge

from

Kamen

SV ml/l 300

MLSS (105° C) g/l 21.9

MLSS (550° C) g/l 18.46

VSS/TSS % 84.3

SVI - 13.6

Parameter UnitFixed Bed

Reactor

CH4  % 3.6

CO2  % 1.0

O2  % 7.2

H2S % 0

Bal % 88.2

Table (3): Chemical analysis of the i nfluent synthetic wastewater

Parameter   Average %  Maximum %  Minimum % 

Ammonia  90.2±7.8  99.7  72.2 

Nitrite  89.0±5.6  94.5  71.6 

Nitrate  52.0±11.5  71.9  33.1 

COD  68.6±10.9  84.3  47.3 

Table (4): Average, maximum and minimum removal efficiency of ammonia