american safe room

Upload: the-seeker-of-all

Post on 30-May-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/14/2019 American Safe Room

    1/23

    American Safe Room

    2009 Product Catalogof

    CBRNE Protection Equipment

    everything you needto build a military grade

    protected space in yourunderground shelter

  • 8/14/2019 American Safe Room

    2/23

    Items in this catalog are either stock items orspecial order items.

    Stock items usually ship within 2 business da

    Special order items require a 50% deposit atime of ordering and the balance due beforeshipping. A picture of the item, ready forshipment, will be provided before the balance due and the item will ship the same day or thenext business day after the payment is made.

    All items are required to be prepaid prior toshipping.

    American Safe Room usually ships by UPS. Otshippers used are Federal Express, DHL, and tPost Service - available upon request.

    Blast doors, blast valves, and ventilation pipesship by USF Reddaway.

    Shipping charges are added to every order. Thquotation from the shipper will be providedattached to the invoice. American Safe Roomnever charges any handling fees.

    Export orders requiring an export licence arecharged an additional $175 and usually takeabout six weeks to get each license.

    Availability and Shipping

    Address American Safe RoomOakland, OR 97462

    Tel. 541-459-1806FAX 503-212-6695

    E-mail [email protected]@mailasr.com

    Websites www.AmericanBombShelter.comwww.AmericanSafeRoom.comwww.AmericanIsolationRoom.com

    DUNS 135227549GSA GS 07F-5638PCAGE 3G8X7

    American Safe Room is the manufacturer of allthe items in this catalog.

    The Safe Cell has been given a commodityjurisdiction by the US State Department anddeemed a Class XIV Munition.

    American Safe Room is registered with the USState Department as a significant defence itemmanufacturer and exporter.Registration number: M16478

    Contact information

    Copyright noticeCopyright 2009 Leonard HenriksonAll right reserved.All text, drawings, photographs, and any othecontent shall not be reproduced by any meanswithout specific written consent.

  • 8/14/2019 American Safe Room

    3/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    4

    Table of Contents

    Critical Components of an Underground Shelter --------------------------------------- 5

    Fundamentals of a Protected Space ---------------------------------------------------- 6

    Safe Cell System Components ---------------------------------------------------------- 7

    Air Filtration Systems----------------------------------------------------------------- 8, 9

    Safe Cell 120 to 240 volt AC with battery backup--------------------------- 8Safe Cell 120 or 240 volt AC ------------------------------------------------- 9Safe Cell 12 or 24 volt DC ---------------------------------------------------- 9Safe Cell 120 or 240 volt AC and 12 volt DC - external blower ------------ 9Complete Blast Protected NBC Filter System ----------------------------------- 9

    Air Filtration Accessories -------------------------------------------------- 10 through 21

    Replacement Filters ------------------------------------------------------------- 10Emergency Backup Hand Pump ------------------------------------------------ 11Automatic Ventilation System -------------------------------------------------- 12External Blowers ---------------------------------------------------------------- 13Automotive Bulkhead Vent Kit ------------------------------------------------- 14Through the Wall Kit ------------------------------------------------------------ 15

    Overpressure Valve --------------------------------------------------------- 16, 17Adjustable Overpressure Valve -------------------------------------------- 18, 19Differential Pressure Gauge ---------------------------------------------------- 20Steel Ventilation Pipes ---------------------------------------------------------- 21

    Blast Protection Equipment ----------------------------------------------- 22 through 24

    Blast Valve ---------------------------------------------------------------------- 22Blast Hatch ---------------------------------------------------------------------- 23Blast Door ----------------------------------------------------------------------- 24

  • 8/14/2019 American Safe Room

    4/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    5

    Blast Doorpage 21

    Emergency Backup Hand Pumppage 11

    12 volt DCautomotive ormarine battery

    (user supplied)110 or 220 volt AC

    50/60 hertzSafe Cellpage 8, 9

    Blast Valvepage 19

    Overpressure Valve

    pages 14, 15

    Blast Valvepage 19

    Blast Hatchpage 20

    Ventilation Pipes

    page 18

    Air intake hose

    Critical Components of an Underground Shelter

    The portals to the outside are the criticalcomponents that protect the occupants ofan underground shelter.

    American Safe Room is the manufacture

    all of the items in this catalog.

    For more information, please see thespecification page for these items inthis catalog and download theinstallation and operation manualsavailable on our websites:

    www.AmericanSafeRoom.comwww.AmericanBombShelter.com

    Ventilation Pipes

    page 18

  • 8/14/2019 American Safe Room

    5/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    6

    A nuclear, biological, and chemical (NBC) safeoom or bomb shelter protects its occupants fromnhaling harmful or deadly airborne toxins suchs very fine particles of radioactive fallout,

    biological toxins, and chemical agents. In the

    past, the United States Government has pouredextensive resources into providing the bestnformation (at theime) for the protection

    of its citizens from NBCwarfare agents. This isnot the case today.

    For protection of theU.S. population we havehe government

    website:www.ready.gov. Ituggests duct tape and

    plastic, then wait forurther officialnstruction. Although theape and plastic method

    would offer somemmediate short termprotection from low leveloxins at lowoncentrations, it would

    be, at best, a short termolution. Most

    overnments tend toonly recommendemergency procedureshat can be afforded byll their citizens.

    As a contrast to mostovernments, both

    Switzerland and Israelequire, and subsidizehe cost of, NBC safeooms in apartment

    buildings. They have

    trict standards in place governing both theonstruction of the room and the ventilation

    equipment protecting the room.

    For protection of some of our military personaland government officials, the U.S. Department ofthe Army - Corps of Engineers has standards bywhich NBC airborne toxic free areas must comply.These standards dictate the differential pressure

    in the safe room (protected space) as well as thedesign of the NBC filter/ventilation system.

    The main reasons whyan un-pressurized roomwill not protect theoccupants for very longis that the room"breaths" - in otherwords, it leaks air bothin and out through thecracks as the externalatmospheric pressurefluctuates - due wind orother atmosphericvariables liketemperature, andbarometric pressureswings due toapproaching weatherfronts. Air constantlytries to normalize itspressure andtemperature betweendifferent variants - as it

    does this, it brings withit whatever that aircontains. Also, in asealed room, there is noaccommodation toreplenish oxygen andexpel the exhaledcarbon dioxide of theoccupants.

    In order to create andmaintain overpressureas well as give the

    required air exchanges to support the air supplyneeds of the sheltered occupants, a safe roommust be equipped with true positive pressureNBC filter/ventilation unit and a means of ametering the exhaust air out of the protectedspace.

    American Safe Room filter/ventilation equipmentand related components are designed andmanufactured specifically for this purpose.

    Fundamentals of a Protected Space

    1. Through the wall kit2. Wall mount flange for hose -

    included with the Safe Cell3. Intake hose: 5-inch diameter/60-

    inches length - included with theSafe Cell

    4. Safe Cell NBC filtration/ventilationunit

    5. Emergency hand pump - shownmounted on the Safe Cell

    6. Digital pressure monitor (externallink - scroll down)

    7. Overpressure valve - ceiling mountalso available

    8. 110/220 Volt AC outlet (standardwall plug) for the Safe Cell

    9. User supplied 12-volt deep cycle(marine) battery - standardautomotive batteries also work

  • 8/14/2019 American Safe Room

    6/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    7

    110/220-volt ACpower cord

    Mounting bolt

    Wall mountingflangefor hose

    Port seal (for storage)

    Air outflow port

    Air intake port

    Portseal

    Emergency Backup Hand Pump

    Air intake hose

    12-volt DCpower cordwith clip leads

    12-volt DCautomotive ormarine battery

    110 or 220-voltAC power source(wall outlet)

    Safe Cell System Components

    The American Safe Room Safe Cell NBC airfiltration systems are positive pressure NBCfilters designed to meet the critical requirementsof the US Army Corp of Engineers documentnumber ETL 1110-3-498 - Design of CollectiveProtection Shelter to Resist Chemical, Biological,and Radiological (CBR) Agents. This provendesign has been deployed worldwide togovernments, militaries, and civilians in blast andfallout shelters, command bunkers, and militaryvehicles. It has been submitted to the US StateDepartment who issued a Commodity Jurisdictionruling it to be a Class XIV munition by the

    because of its effectiveness in filtering warfaregases and particulates.

    This series of filters all have a system airflowrating of 100 cubic meters per hour of filtered air.You can get them a variety of voltages fordifferent applications. See pages 7 and 8 formore information.

    The Safe Cell and its related components havbeen especially designed with the end user aninstaller in mind. All components are turn keysystems - including all components, hardwareand step by step technical documentation foreasy installation.

    Also available are the Iso-Shield 120 and theIso-Shield 800 particulate air filtration system

    The Iso-Shield 120 is designed to creathospital grade isolation room in anysuitably sized and sealed room.

    The Iso-Shield 800 is designed to creatCDC grade isolation room in any hospitroom.

    Please note: not all systems haveevery feature shown above

  • 8/14/2019 American Safe Room

    7/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    8

    DescriptionThe Safe Cell is an NBC air filtration systemdesigned to overpressure a protected space. Itmounts on a wall, connects to an air intake pipeand contains a bank of filters and a blower (fan).

    This model features a built in power supply thattrickle charges a user-supplied 12 volt battery,automatically reverts to the battery when the ACpower drops out, then automatically reverts tothe AC when it comes back online, and thenautomatically recharges the battery.

    Parts supplied with this item Safe Cell air filter Wall mount kit Air intake hose Wall mount flange for air intake hose

    Electrical cords - AC and DC Installation and operation manual

    Price and Availability

    Part number ASR-100-AV-NBC

    Price $2,395.00/each

    Availability Stock item

    Specifications

    Air flow - filtration mode 100 CMH (60 CFM)

    Air flow - ventilation mode 200 CMH (120 CFM)

    Noise level 60 dB(A)

    Weight 49 pounds (22 kilograms)

    Electrical - primary 110 240 volt AC

    Electrical - backup 12 volt DC

    Electrical - draw AC 2.5 amps at 110 VAC

    Electrical - draw DC 4.3 amps at 12 VDC

    Fuse AC 4 amps

    Fuse DC 6 amps

    Blower MTBF rating 2,000 hours

    Safe Cell NBC Air Filter

    Inches (millimeters)

    For more information, please see the installationnd operation manual for this item available

    online at: www.AmericanSafeRoom.com

  • 8/14/2019 American Safe Room

    8/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    9

    Description

    This kit combines several of our productsdesigned to give you blast protected filtered ainside your underground shelter.

    Parts supplied with this item Safe Cell air filter - one each 50 PSI Blast Valves - two each Overpressure Valve - one each Emergency Backup Hand Pump - one eac Installation and operation manuals

    Price and Availability

    Part number ASR-100-AV-NBC-CO

    Price $3,800.00/e

    Availability Stock i

    Safe Cell Options

    Specialized VoltagesThe Safe Cell can also be purchased configured toonly operate off of a DC single voltage.The automatic switching power supply is notinstalled in these models:

    DC only Safe Cells

    Part number ASR-100-12V-NBC (12 volt DC)

    Part number ASR-100-24V-NBC (24 volt DC)

    Price $2,195.00/each

    Availability Stock item

    Blast Protected Filtration SystemThis kit has everything you need to outfit yourshelter. Shipping is included in the price on thitem only.

    For more information, please see the installatiand operation manual for this item availableonline at: www.AmericanSafeRoom.com

  • 8/14/2019 American Safe Room

    9/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    10

    Replacement Filters

    HEPA Filter Warfare Gas Carbon Adsorber

    DescriptionThe nuclear grade HEPA filter is a special filter wehave made just for our application. Each HEPAilter is individually tested to MIL-STD-282

    before it leaves the factory. The penetration andctual airflow rate are indicated on the label.

    Every HEPA filter is individually DOP tested.These filters are also UL rated.

    Specifications

    Media Glass micro fiber

    Material Fire retardant particle board

    Separators Aluminum

    Bond Polyurethane foam

    Gasket Neoprene - both sides

    Factory test Certified 99.97% efficiency

    Price and Availability

    Part number ASR-50-HEPA

    Price $335.00/each

    Availability Stock item

    Pre-Filter Set

    Price and Availability

    Part number ASR-50-PF

    Price $55.00/set

    Availability Stock item

    DescriptionThe nuclear grade war gas adsorber is a blocksieve adsorption filter cell consisting of twocontainment medias and a center block of

    blended granule nuclear grade war gas carbonand ASZM-TEDA.

    This special blend of two kinds of activatedcarbon adsorbs warfare gases and radioactiveiodine in order to meet the requirements of USArmy Corps of Engineers ETL 1110-3-498standard for war gas removal.

    Price and Availability

    Part number ASR-50-HEPA

    Price $395.00/each

    Availability Stock item

    For more information, please see the detail orderpage for these items at:www.AmericanSafeRoom.com

    Price and Availability

    Part number ASR-50-FILTERS

    Price $700.00/set

    Availability Stock item

    Complete replecement setncluded one each of the filters on this page.

  • 8/14/2019 American Safe Room

    10/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    11

    DescriptionThe ASR-50-BB Emergency Hand Pump willintroduce safe, breathable air into your protecspace when all other electrical supplies have

    failed. It slip-fits onto the top port of all modeof the Safe Cell.

    Parts supplied with this item Emergency Backup Hand Pump Installation and operation manual

    Price and Availability

    Part number ASR-50

    Price $315.00/e

    Availability Stock i

    Specifications

    Material - housing ABS Plastic

    Material - bellows Synthetic rubber

    Weight 8 pounds (3.6 kilograms)

    Internal volume 1216 cubic inches (19,927 cc)

    Stroke length 10.75 inches (27 centimeters)

    Emergency Backup Hand Pump

    Inches (millimeters)

    For more information, please see the installationand operation manual for this item availableonline at: www.AmericanSafeRoom.com

  • 8/14/2019 American Safe Room

    11/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    12

    Automatic Ventilation System

    DescriptionThe Automatic Ventilation System will providedaily unfiltered ventilation to an underground

    shelter in order to evacuate moisture and odors.

    It mounts on a wall adjacent to the Safe Cell.

    The quick connect hose allows easy operationusing the air intake hose from the Safe Cell andthe existing ventilation pipes.

    The blower is a marine grade, long life airhandler that is controlled by the timer.

    Parts supplied with this item

    250 CFM blower Wall mount bracket and fasteners Analog automatic timer

    Price and Availability

    Part number ASR-50-AB

    Price $645.00/each

    Availability Stock itemSpecifications

    Air flow - blower rating 250 CFM

    Power consumption - 120 volt AC 1.4 amp

    Fuse 4 amps

    Blower MTBF rating 10,000 hours

    For more information, please see the installationnd operation manual for this item available

    online at: www.AmericanBombShelter.com

    The air intake hose attached to the Safe Cellair intake hose

    The air intake hose attached to theventilation blower

  • 8/14/2019 American Safe Room

    12/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    13

    External Blowers

    DescriptionThese external blowers will slip into the top(outflow) port of any Safe Cell and draw airthrough the internal blower. They are rated focontinuous duty in a marine environment.

    The AC models have a switch and a fuse. The models are supplied with battery terminal clip

    Parts supplied with this item One each blower

    Price and Availability

    Part number ASR-50-HD110 (110 volt

    Part number ASR-50-HD220 (220 volt

    Part number ASR-50-HD12 (12 volt

    Part number ASR-50-HD24 (24 volt

    Price $365.00/e

    Availability Stock i

    Specifications

    Airflow - all models 250 CFM

    Weight - 120/220 volt AC 8 pounds (3.6 kg)

    Weight - 12/24 volt DC 6 pounds (2.7 kg)

    Power consumption - 120 volt AC 1.4 amp

    Power consumption - 220 volt AC .75 amp

    Power consumption - 12 volt DC 11.5 amps

    Power consumption - 24 volt DC 5.3 amps

    MTBF rating 10,000 hours

  • 8/14/2019 American Safe Room

    13/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    14

    Automotive Bulkhead Vent Kit

    DescriptionThe Automotive Bulkhead Vent Kit is designed tobe mounted through a wall of a vehicle. Itprovided a heavy duty splash resistant shroudoutside the vehicle and a quick connection fittingfor the Safe Cell inside the vehicle.

    FunctionThis kit is used to supply an outside air source forthe 12 or 24 volt Safe Cell (ASR-100-12V/24V-NBC) in order to overpressure the crewcompartment. The cut off valve can be used toshut down the port when the filter is not inoperation.

    Parts supplied with this item External steel shroud Gaskets - 2 Quick connect fitting (port) Cut off valve 90 degree fitting with connector Mounting screws Installation manual

    Price and Availability

    Part number ASR-50-AD

    Price $495.00/each

    Availability Stock item

    Specifications

    Material - outside shroud steel

    Finish - outside shroud primer

    Material - fittings ABS plastic

    Material - cut off valve ABS plastic

    Material - gaskets BUNA rubber

    Inches

    For more information, please see the installationnd operation manual for this item available

    online at: www.AmericanSafeRoom.com

  • 8/14/2019 American Safe Room

    14/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    15

    Through the Wall Kit

    DescriptionThis kit allows you to run a duct through aresidential style wall - with a quick connect fitfor the Safe Cell on the inside and either aregister grill or a rain hood on the outside.

    It also allows you to shut off the duct when yofilter is not in use.

    Specifications

    Material ABS plastic and aluminum

    Duct size 4 inches internal diameter

    For more information, please see the installationand operation manual for this item availableonline at: www.AmericanSafeRoom.com

    Parts supplied with this item Rain hood with insect screen Ducting Register grill Fasteners Installation manual

    Price and Availability

    Part number ASR-50-WD

    Price $195.00/each

    Availability Stock item

  • 8/14/2019 American Safe Room

    15/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    16

    Overpressure Valve

    DescriptionThe Overpressure Valve is a one-way check valvethat will only open after the shelter hasoverpressure (positive pressure in relation to theoutside pressure). If the pressure in the shelterdrops, this valve closes keeping toxins out ofyour shelter. It also meters the air flowing out ofyour shelter working with the filter to maintainoverpressure.

    These valves can either be mounted on a wall orceiling or directly onto a Blast Valve. Please seethe following page for the differentconfigurations.

    Parts supplied with this itemNote: all parts are supplied with every valve forevery type of installation shown on the followingpage:

    Overpressure valve Wall mounting plate Straight adapter 90 degree adapter

    Price and Availability

    Part number ASR-50-OP

    Price $165.00/each

    Availability Stock item

    Specifications

    Material ABS Plastic

    Opening pressure 0.3 inches of water gauge

    Maximum pressure 2.5 PSIWeight 3 pounds (1.4 kilograms)

    For more information, please see the installationnd operation manual for this item available

    online at: www.AmericanSafeRoom.com

  • 8/14/2019 American Safe Room

    16/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    17

    Wall mount with Blast ValveWall mount

    Ceiling mount Ceiling mount with Blast Valve

    Inches (millimeters) Inches (millimeters)

    Inches (millimeters) Inches (millimeters)

    Overpressure Valve Dimensions

  • 8/14/2019 American Safe Room

    17/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    18

    Adjustable Overpressure Valve

    DescriptionThe Adjustable Overpressure Valve is a one-way

    check valve that will only open after the shelterhas overpressure (positive pressure in relation tothe outside pressure). If the pressure in theshelter drops, this valve closes keeping toxinsout of your shelter. It also meters the air flowingout of your shelter working with the filter tomaintain overpressure.

    It is used to meter the air flowing out of yourshelter. The opening pressure of this valve hasbeen calibrated to work with the Safe Cell tocreate and maintain positive pressure in yourprotected space.

    These valves can either be mounted on a wall orceiling or directly onto a Blast Valve. Please seethe following page for the differentconfigurations.

    Parts supplied with this itemNote: all parts are supplied with every valve forevery type of installation shown on the followingpage:

    Adjustable overpressure valve Wall mounting plate 90 degree adapter

    Price and Availability

    Part number ASR-100-AOP

    Price $245.00/each

    Availability Stock item

    Specifications

    Material ABS Plastic

    Opening pressure 0.3 inches of water gauge

    Maximum pressure 2.5 PSIWeight 3 pounds (1.4 kilograms)

    For more information, please see the installationnd operation manual for this item available

    online at: www.AmericanSafeRoom.com

    Overpressure valve

    Mounting plate

    Wall mountadapter

    This valve was designed to be used with the

    Differential Pressure Gauge to adjust theoverpressure in a shelter.

    Please see page 18 for more information on thisauge.

  • 8/14/2019 American Safe Room

    18/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    19

    Adjustable Overpressure Valve Dimensions

    Wall mount with Blast ValveWall mount

    Ceiling mount Ceiling mount with Blast Valve

    Inches (millimeters) Inches (millimeters)

    Inches (millimeters) Inches (millimeters)

  • 8/14/2019 American Safe Room

    19/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    20

    Differential Pressure Gauge

    DescriptionThe American Safe Room Differential PressureGauge displays the difference in air pressurebetween the inside and outside of a shelter. Ithas a sampling tube that goes through the wallor ceiling in order to read the outside air

    pressure. Another sampling tube is on the back ofthe gauge inside the housing and the differencein air pressure is displayed by a needle on a dialgauge.

    When you do not have the Safe Cell NBCoverpressure air filter on, a properly installeddifferential pressure gauge will read zero becausethere is no difference in the air pressure inside,and outside of the shelter. When you start theSafe Cell, the gauge will read a higher pressure.

    There are three ranges of gauges available thatdisplays positive overpressures:

    1. zero to 0.5-inches of water columnpart number ASR-05-DPG

    2. zero to 1-inch of water columnpart number ASR-10-DPG(special order item)

    3. zero to 25-mm of water columnpart number ASR-25-DPG(special order item)

    Price and AvailabilityPart number see 1 through 3 above

    Price $295.00/each

    Availability see 1 through 3 above

    Specifications

    Material ABS

    Maximum outside pressure 30 PSI

    For more information, please see the installationnd operation manual for this item available

    online at: www.AmericanSafeRoom.com

    Note:This gauge must be mounted level or itwill not give accurate readings

  • 8/14/2019 American Safe Room

    20/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    21

    DescriptionThese welded steel ventilation ducts are built order in pairs - intake and outflow. They arerated for 50 PSI. There are drawings and aworksheet to fill out in the manual available owww.AmericanBombShelter.com. Once we havthe dimensions and orientation you require, w

    will send you a formal quotation for parts andshipping.

    FunctionThe Ventilation Ducts provide a conduit for airintake and outflow. They must be used in pairand Blast Valves are highly recommended for blast resistant shelters. The mounting plate hodiameter pattern is the same as the Blast Valv

    Parts supplied with this item Ventilation Ducts

    Concrete wedge anchor fasteners Installation manual

    Price and Availability

    Part number ASR-50

    Price quoted for each installa

    Availability Special Order i

    Specifications

    Material steel

    Finish primer

    Construction continuous weldment

    Internal diameter 4 inches (101.6 mm)

    External diameter 4.5 inches (114.3 mm)

    Steel Ventilation Pipes

    For more information, please see the installationand operation manual for this item availableonline at: www.AmericanBombShelter.com

  • 8/14/2019 American Safe Room

    21/23

    American Safe Room, Inc.www.AmericanSafeRoom.com

    009 Catalogevision A-07

    22

    DescriptionThe automatic double acting Blast Valves are

    used to protect the Safe Cell and the occupantsfrom the high pressure wave caused by a nearbydetonation.

    These valves are designed to mount onto aconcrete wall or ceiling over the air intake andoutflow pipes with the included wedge anchors.

    The internal valves are normally in the centralneutral position and then automatically slam shutwhen the initial blast wave from an nearbyexplosion hits and then automatically closes asecond time when the vacuum that follows thepressure wave hits.

    The Blast Valves need to be used on every portalin your shelter. The air intake pipe and the otheron the air outflow pipe need blast protection andany other portal - such as septic vents.

    Parts supplied with this item One each Blast Valve Concrete wedge anchors Installation and operation manual

    Price and Availability

    Part number ASR-101-BV

    Price $475.00/each

    Availability Stock item

    Specifications

    Material - case steel

    Material - valve assembly stainless steel

    Material - bushings bronze

    Material - seals BUNA rubber

    Construction weldment

    Closing pressure 0.5 PSI (3.5 kilopascal)

    Maximum pressure 102 PSI (7 bar)

    For more information, please see the installationnd operation manual for this item available

    online at: www.AmericanBombShelter.com

    Inches (millimeters)

    Blast Valve

  • 8/14/2019 American Safe Room

    22/23

    American Safe Roomwww.AmericanSafeRoom

    2009 CatalogRevision A-07

    23

    DescriptionThe Blast Hatch is designed to cap a vertical ron an underground shelter and give theoccupants protection from a 50 PSI (3.4 bar)pressure wave and a 14.5 PSI (1 bar) reboundload.

    It is designed to be installed after the concreteriser has been poured and cured.

    Parts supplied with this item Blast Hatch Concrete wedge anchors Pneumatic lift strut Lift strut anchor Installation and operation manual

    Price and Availability

    Part number ASR-50

    Price $3,195.00/e

    Availability Special Order i

    Blast Hatch

    1612

    Specifications

    Material - door 3/16 inch (7.9 mm) steel

    Material - frame 1/4 inch (9.5 mm) steel

    Material - bushings silicon bronze

    Material - gas seal closed cell foam rubber

    Construction Cut, formed and welded

    Inches

    For more information, please see the installationand operation manual for this item availableonline at: www.AmericanBombShelter.com

  • 8/14/2019 American Safe Room

    23/23

    24

    DescriptionThis Blast Door is designed to withstand a 50 PSI(3.4 bar) pressure wave and a 14.5 PSI (1 bar)rebound load. It must be installed with the doorseated toward the pressure threat (usuallyoutward).

    It is designed to be installed after the concretewall has been poured and cured. Once the door ispositioned and attached with the anchors, thedoor cavity is filled with concrete.

    Price and Availability

    Part number ASR-50-BD

    Price $3,995.00/each

    Availability Special Order item

    Specifications

    Material - door 3/16 inch (7.9 mm) steel

    Material - frame 1/4 inch (9.5 mm) steel

    Material - bushings silicon bronze

    Material - gas seal closed cell foam rubber

    Construction Cut, formed and welded

    Blast Door

    Standard opening size shown.Custom sizes available.

    32(813)

    72

    (1829)

    6(152)

    Inches (millimeters)