    TheEC9800

    ambient

    air

    analyzers

    are

    intelligent

    analyzers

    with

    state

    of

    the

    art

    features,

    outstanding

    gas

    measurement

    sensitivityand reliability,anda lowcostofownership.Theanalyzers in this familyprovidemeasurementsofozone,

    carbonmonoxide,sulfurdioxide,andnitrogenoxidesandareallUSEPAEquivalentMethodcertified.

    TheEC9800BSeriesanalyzersrequireexternalpumpsgivingthesystem integratorthepossibilityofusingmorethan

    onepumpperanalyzer.Byunbundlingmanyofthesupportinghardware itemsandsimplifyingtheoperationofthese

    analyzerstheEC9800BseriesprovidesoutstandingperformanceinlowcostbuthighperformanceOEMtypeanalyzers.

    Similarly, the choice of calibration techniques (e.g. external zero/span valves, internal zero/span check) can be

    optimized for thesystemallowingmore flexibility for the sys

    temintegrator.

    FEATURESINCLUDED

    ON

    ALL

    B

    SERIES

    ANALYZERS

    :

    Selectable ppm, ppb, mg/m3 or ug/m3 corrected for

    temperatureandpressurevariations.

    Gaspressure, temperaturemeasurement and compensa

    tion for accurate concentrationmeasurements under all

    conditions.

    Sampleflowratesareestablishedbybuiltincriticalorifice

    andcontrolledbyanexternalsamplepump.

    Softwarealgorithmshandleall internaladjustments,performdiagnostics, indicateerrors,displaystatus, linearize

    andmakecalculationsofconcentration.Theonlyoperatorfunctionsareroutinemaintenanceofpneumaticsand

    periodiccalibrationoftheunit.

    Kalmanadaptive

    filter

    for

    continuously

    optimized

    noise

    and

    response

    time.

    Menu driven large alphanumeric display provides a complete display of gasmeasurements, instrument status,

    setupparametersanddatatrendingdisplay.

    Eventlogforautomaticrecordingofsignificantmaintenance,calibration,anddiagnosticevents.

    Allanalyzertemperaturesdisplayedonasinglemenuscreen.

    EC9800analyzersfeatureinternalFlashROMdatastorageforinexcessof135daysof5minuteaverages.Datacan

    bedownloadedusingtheanalyzersRS232portorremotelyusingamodem.Fullremotecontrolofeachanalyzer

    overmultidropRS232serialportwithaPC.FirmwareeasilyupdatedutilizingUSBorRS232port.

    Internal lithiumbatterybackupofconfigurationparametersensuresthatnormaloperation isrestoredevenafter

    apowerinterruption.

    Folddownfrontpanelprovideseasyaccesstoexpendableitemssuchasparticulatefiltersandcharcoalscrubbers,

    andpower

    control

    switches.

    Commonchassis,electronics,andsoftware.Slideoffchassiscoverprovideseasyaccesstoallinternalconstruction.

    Optionalmanualoperatorcontrolledorautomaticinternalzero/spancheck.

    Optionalexternalzerospanvalves.

    Lowcarbonfootprintandutilizes12VDCinternalelectronics.

    USEPAEquivalentreferencemethodcertification.

    Special versionsof theseanalyzersareavailable formeasuring carbondioxide,background traceprecursor levelsof

    carbonmonoxide,nitrogenoxides and sulfurdioxide,NOy andammonia,high concentrationnitrogenoxides, sulfur

    dioxidesandcarbonmonoxide.

    EECOTECHCOTECHEC9800BSEC9800BSERIESERIESGGASASAANALYZERSNALYZERS

  • 7/31/2019 American Ecotech Series B Analyzers.sflb

    2/3

    OZONEANALYZEREC9810BTheEC9810BOzoneAnalyzercombinesmicroprocessorcontrolwith

    ultraviolet(UV)

    photometry

    to

    measure

    O3

    in

    the

    range

    of

    050

    ppb

    or020ppmwithadetectionlimitof0.5ppb.

    TheEC9810BusestheprinciplethatcertainwavelengthsofUV light

    areabsorbedbyozone(BeerLambertRelationship).Amercuryvapor

    lampisusedtoprojectabeamof215nmlightthroughaglasssam

    plecellthatalternatelycontainsthemeasurementsampleandthena

    reference sample that is selectively scrubbed of ozone. The differ

    ence inUV lightattenuationbetweenthesampleand thereference

    gas streamsprovidesanaccurateand reliablemeasurementof the

    ozoneconcentration.

    FEATURES: Ozone measurement with photometric dualchannel technique

    providesreliable,nearlydriftfreemeasurement.

    Theuseofasmallglassmeasurementcellboostsdataqualityand

    performance.

    Withonlyonecell,lowflowandnomirrors,cleaningfrequencyis

    lessthan thatneeded forothersystems,whileexpendables life

    timeisextended.

    Photometer allows for manual operator controlled calibration

    zero/span sequence or a timed 24hour cycle at an operator

    specifiedtimeorremotelycontrolledcalibrationbyexternalcon

    tactclosure. Fullfivepointcalibration.

    CARBONMONOXIDEANALYZEREC9830BTheEC9830BCarbonMonoxideAnalyzerutilizesNDIRGasFilterCorrelationphotometryandmicroprocessorcontrol tomeasureCO in the

    rangeof0200ppmwithadetectionlimitof50ppb.

    The EC9830 rotating gas filter correlation wheel has two gas filled

    cells.OnecontainsCOwhichremovesallIRenergyintheCOabsorp

    tionwavelengths thereby creating a reference beam. The other cell

    containsnitrogenwhichallowstheCOabsorptionspectralbandstobe

    measuredwiththesamplegas.ThedifferenceinIRenergysensedby

    the solid state detector duringmeasurement and reference cycle is

    proportionaltotheCOpresentinthemeasurementcell.Thisratiomet

    ric techniqueeliminatesmost sourcesofdrift (i.e. interference from

    CO2andH2O)typicalofotherlesssophisticatedinfraredanalyzers.

    TheEC9830B

    is

    typically

    used

    with

    external

    calibration

    gases

    for

    auto

    maticzero/spanchecks.Highpressurespanvalvesareavailablewhen

    usingmoderatelypressurizedgassources.

    FEATURES: Long life infrared(IR)sourceandadvancedgasfilterwheelallows

    fortroublefreeoperationandminimummaintenance.

    Builtinzeroairscrubberensureszerostabilitywithnoneedforan

    externalscrubber.

    Temperaturestabilizedfilterandgasfilterwheelensureminimum

    spandrift.

    Customdesignednafiondryervirtuallyeliminatesinferenceof

    watervapororcarbondioxideduringmeasurement.

    NITROGENOXIDESANALYZEREC9841BTheEC9841BNitrogenOxidesAnalyzerutilizesmicroprocessor c

    troland

    chemiluminescence

    detection

    to

    measure

    NO,

    NO2

    and

    N

    intherangesof050ppband020ppmwithadetectionlimitof

    ppb.

    TheEC9841Bprincipleofmeasurementisbaseduponthereaction

    theNOmoleculewithan internal sourceofozone inanevacua

    reaction cell that results in theemissionof light.The EC9841B

    singlechannelinstrumentthatmeasurestheNOinasamplegast

    isalternatelypassedthroughoraroundacatalyticconvertertoc

    verttheNO2toNO.Themeasurementoftheuntreatedsamplep

    vides a NO value and themeasurement of the converted sam

    provides theNOxmeasurementwithNO2 calculated as the dif

    encebetweenthetwomeasurements.

    FEATURES:

    Fastresponseandlownoiseachievedthroughauniquelowp

    surereactioncelldesign.

    Autozero routine allows the analyzer to periodically check

    correct for background illumination, virtually eliminating z

    drift.

    Low sample flow rate extends molybdenum converter

    320ml/min.

    Theuseofelectropolishedstainlesssteelreactioncellresult

    decreasedmaintenanceandgreatlyimprovedlongevity.

    SULPHURDIOXIDESANALYZEREC9850BThe EC9850B Sulphur Dioxide Analyzer combines microproces

    controlwithfluorescencedetectiontomeasureSO2intherange

    050ppband020ppmwithadetectionlimitof0.5ppb.

    TheEC9850dependson the fluorescent radiationproducedbyS

    moleculeswhenexcitedbyUV radiation.TheexcitationU.V. ra

    tionismeasuredbyareferencedetectorandthefluorescencera

    tion (SO2) ismeasured by a photomultiplier tube (PMT). The t

    measurements are ratioed in a classical dualchannel technique

    minimizetheeffectsofvariationinlampintensity,opticalcontam

    tionandcommonPMTdriftcharacteristics.Ahydrocarbonscrubb

    system,containingnoconsumablematerials,also removes inter

    inghydrocarbonspriortotheambientsamplebeingmeasured.

    FEATURES: AcustomdesignedzincUVsourceproducesasinglespectral

    at214nmallowingtheanalyzertobefreefromwatervapor

    terference,eveninveryhighhumidityconditions.

    Optionalinternalzero/spancheckdevicewhichutilizesaconst

    temperaturepermeationtubetogenerateaknownSO2span

    concentration.