am282 manual audiometer tm286 auto tymp training

68
Advancing Frontline Care TM AM282 Manual Audiometer & TM286 Auto Tymp Training .

Upload: others

Post on 16-Jan-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

AM282 Manual Audiometer &  TM286 Auto Tymp

Training

.

Page 2: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Target Markets & Selling Geography 

Front line primary care providers:•

Internal Medicine

Family Practice•

Pediatrics

North American Distribution•

Available in the United States and Canada

Selling through General Med/Surg

Distribution–

No longer offering through Specialty or School Dealers

.

Page 3: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

AM232 versus AM282

Page 4: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

AM232 versus AM282

AM232 (Old) AM282 (New)

Versions 23200 and 23210One version 28200 (audiometry w/battery compartment) batteries (5 ea. AA alkaline or re-chargeable) not included

Large profile Smaller profile, less counter space required

No Case Case includedDated outer housings New outer housings/componentsDated buttonology symbols New buttonology symbolsNA Ear Tone Insert Phone (optional)Headset External Headset ExternalList Price: $1237; $1428 List Price: $1499

Page 5: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

“New”

AM282 Manual Audiometer •

Replaces current AM232 manual screening audiometer

Continues to provide multiple frequencies (125Hz to 8000Hz)•

Wide intensity range

Compact, light-weight•

Dealer Discount 30%

Dealer Best Price: $1049.58•

CPT Codes: 92551, 92552

Estimate Date: 9/27/10.

$1499.40

Page 6: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM262 versus TM286

Page 7: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM262 versus TM286TM262 (Old) TM286 (New)

Versions 26200 and 26230 One version 28600 (tymp, tymp refl, aud)

RS232 connectivityUSB connectivity to external printer and CPU (PCL3 or PCL3GUI driver for ext. printer)

Dated outer housings New outer housings/componentsMemory Storage-8 tests Memory Storage-12 tests

Program Mode-customization Program Mode-customization expansion at power up

Dated buttonology symbols New buttonology symbolsNA Ear Tone Insert Phone (optional)Headset External Headset ExternalTymp Eartips (6 sizes) Tymp Eartips (6 sizes)4” Thermal Paper (1 pkg 5 rolls) 4” Thermal Paper (1 pkg 5 rolls)List Price: $3906; $4533 List Price: $4760

Page 8: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

“New”

TM286 Auto Tymp•

Replaces current TM262 Auto Tymp•

Three-in-one screening product for tympanometry, acoustic reflex

and audiometry

testing•

Continues to provide multiple frequencies (125Hz to 8000Hz)•

Wide intensity range•

USB for connectivity•

Portable design•

Dealer Discount: 30%•

Dealer Best Price: $3331.76•

CPT Codes: 92551, 92552, 92567, 92568

Estimate Date: 9/27/10

. $4760

Page 9: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

“New”

AM282 & TM286

Launch Plan•

Dealer and Ambulatory Care Sales Force Notifications-sent on 7/19 & 8/18

Ambulatory Care Demo Units-shipping

week of 9/20•

Training (Sales Force, Customer Service, Tech Support, Services)-week of 9/20

Pulse Updated

(Part #s, Price List, Sales Brochure, Reimbursement Sheets, FAQs, Owner’s Manuals (English & French)-in process of being updated

MARCOM

(Sales Brochure, Physician Newsletter, PR- Repertoire, Trade Show Graphics, Web In-service, Google

Search Campaign, Catalog Updates, Pulse Update, Eblast- dealer/end-users)

Note: NO promotions or EOL modules

.

Page 10: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

US Part # & Pricing “New”

.

NEWAM282 Manual Audiometer Part Numbers

WA Part Number WA Description 2011 List Price

Dealer Discount

2011 Dealer Best Price

28200 AM282 Manual Audiometer (w case) $1,499.40 30% $1,049.58

28201 AM282 Power Supply (to 282) $ 160.00 30% $ 112.00

28202 AM282 Carry Case $ 90.00 30% $ 63.00

28204 AM282 User Manual $ 75.00 30% $ 52.50

28207 AM282, Power Plug (to wall) $ 75.00 30% $ 52.50

28208 AM282 Audiogram Forms, 1 Pad of 50 $ 15.00 30% $ 10.50

NEWTM286 Auto Tymp Part Numbers

WA Part Number WA Description 2011 List Price

Dealer Discoun

t2011 Dealer Best Price

28600 TM286 Auto Tymp $ 4,760 30% $3,331.76

28601 TM286 Power Brick $ 210 30% $ 147.00

28602 TM286 Cord, Power, Hosp Grade $ 75 30% $ 52.50

28603 TM286 User Manual $ 35 30% $ 24.50

28604 TM286 Quick Reference Guide $ 25 30% $ 17.50

Page 11: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

US Part # & Pricing “Shared”

.

NEWAM282/TM286 Shared Part Numbers

28203 Audiometry Ear Tone Insert Phone $1,300.00 30%

$ 910.00

28206 Threshold Audiometry Card $ 40.00 30% $ 28.00

28209 Audiometry Headset External $ 750.00 30%

$ 525.00

28210 Audiometry Y-Cord, Headset, 2 Plug Shielded $ 125.00 30% $ 87.50

EXISTING AM282/TM286 (AM232/TM262) Shared Part No.

(For Reference Only)

23220 Audiometry Patient Response Switch $ 275.00 30% $ 192.50

23221 Audiometry Single Patch Cord, 2-Conductor $ 40.00 30% $ 28.00

23222 Audiometry AudioCups $ 750.00 30% $ 525.00

(Note: There were some part # they were obsoleted/discontinued)

Page 12: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Sales Collateral•

AM282 Sales Brochure (SM2000)

TM286 Sales Brochure (SM2001)•

Reimbursement Sheet-Audiometry

(MC4593SS)

Reimbursement Sheet-Tympanometry

(MC4595)•

Powerpoint

Training Presentation

2-slide Dealer Presentation/Comparative Matrix•

Technical Specifications Document

Frequently Asked Questions Document•

WA Website/WA Pulse

Online In-service Video (coming soon)

Page 13: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Service, Calibration, WarrantyNew Products:•

Service at GSI with RMA, Loaners

Calibration at WA or approved Dealer•

One year warranty on product/accessories

Old Products:•

Provide support for up to 5 years (or until parts are no longer available),

Including making Daily Use

Accessories

(tips, paper, etc.) and Replacement Accessories

(cord,

batteries, etc.)..

Page 14: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Frequently Asked Questions •

Q. What are the comparable GSI products to the old AM 232 and TM 262…and when were they launched?A. GSI 17 is the WA AM232…GSI launched in 1990; GSI 38 is the WA TM262…GSI launched in 1993

Q. What are the comparable GSI products to the new AM 282 and TM 286…and when were they launched?A. GSI 18 is the WA AM282…GSI launched in 10/08; GSI 39 is the WA TM286…GSI launched in 3/09

Q. What is decibel (dB)?A. A logarithmic unit of sound intensity (loudness)

Q. What is Hertz (Hz)?A. The unit of frequency, cycles per second (pitch)

Page 15: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Who is Demant

Holdings?•

GSI, Viaysis, Cardinal Health, William Demant

Holding Group

(WDHG)

WDHG is a leading International Hearing Healthcare company within Hearing Aids, Audiometric Equipment, and Personal Communication

WDHG acquired our partner, Cardinal Health (GSI products)

Other businesses within WDHG include Maico, Interacoutics and Amplivox.

Page 16: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

AM282 Manual Screening Audiometer

.

Page 17: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Overview •

Operation/Use

Unpacking/Inspection/Standard Accessories•

Routine Maintenance

Standards/Specs/Replacement Parts/Optional Accessories

.

Page 18: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

AM282 Use

Pure Tone Audiometry–

Air Conduction Thresholds

Air Conduction Screening–

Fast Accurate Testing

Screening–

Physician Office Screening•

Patients Report Difficulty Hearing/Understanding

Parents voice concern about children’s hearing

Page 19: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

AM282 Use

Age Range –

pre-kindergarten –

adult•

Ideal for physician offices–

Portable

Minimal training required to perform evaluations

DOT Physicals•

OSHA Physicals

FAA Physicals•

School Physicals

Page 20: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Buttonology

Page 21: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Buttonology

Page 22: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

AM282 Use

Solution for every screening situation–

Calibration data for TDH39 (standard)

Calibration data for EAR3A insert phones (option)•

Calibration required if purchased separately

Power -

AC power •

Battery compartment exists

Requires 5AA alkaline or rechargeable batteries – not included

Instrument Part Number: 28200

Page 23: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

AM282 Front Panel

Page 24: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Serial Number

Page 25: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Page 26: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Standard accessories

28209/8000-0177•

Headphones

28202•

Carrying case

28201 AND 28207•

Power module, power plug

Page 27: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Standard Accessories

28208 -

Audiogram pad

Part #

Page 28: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Standard Accessories - 28202

Page 29: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Routine Maintenance 

• Biologic Check• Calibration• Cleaning.

Page 30: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Biologic Check

Operator listens to headphones•

Changes loudness and pitch

Listen for distortion or other odd sounds•

Make sure it’s working as expected

Page 31: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Calibration

How frequently should the instrument be calibrated?–

One time per year

Any time new headphones are purchased (even if they’re identical replacements)

Page 32: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Cleaning

Wipe with soft (optional –

damp) dust-free cloth•

Okay to use mild cleaning agent

Do NOT get any moisture into the speakers of the headphones

Page 33: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

AM282 Specs

Screening Audiometer•

Pure-Tone Air conduction

Frequency range 125 Hz to 8000 Hz–

Stimulus choices•

Steady, pulsed or FM

Intensity Range -10 dB to 90 dB HL•

Extended Range adds 10 dB HL to each frequency (+10dB button)

Page 34: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Optional Accessories

28203•

Insert phones (requires Calibration at factory)

23222•

Audiocups

23220•

Handswitch

23221•

Patch Cords

Note: 1 cord needed per connection (2 for headset, 1 for handswitch)

Page 35: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Replacement Parts

8000-0177•

Headset assembly

28208•

Audiogram pads 50 sheets

28210•

Audiometry

y-

cord 2

plug shielded

Page 36: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM286 Auto Tymp

.

Page 37: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Overview •

Operation/Use

Unpacking/Inspection/Standard Accessories•

Routine Maintenance

Standards/Specs/Replacement Parts/Optional Accessories

.

Page 38: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM286 Use

Multi-function Screening Unit–

Tympanometry– Test mobility of Middle Ear System

Reflex screening – Verify Tympanometry

results

– Verify need for further testing–

Pure-tone Audiometry– Frequency Range 125 Hz –

8000 Hz

– Stimulus Choice –

Steady, Pulsed, FM

– Intensity Range = -10dB to 90dB HL– Extended Range –

adds 10 dB HL to each frequency (+10)

Page 39: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Buttonology

Page 40: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Buttonology

Page 41: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Probe LED Indicators

Page 42: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Program Mode•

Sub-Menu (Program mode) –

allows preferences to

be stored•

Sub-menu that allows you to configure test

parameters –

Allows you to select parameters of screening

Customize print settings

Can change settings for an individual test –

Over-ride test parameters for patient specific evaluation

Page 43: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM286 Test Results

Stores Data –

save up to 12 test pages•

View test “pages”

by pressing (page)

Scroll through saved tests with the < and > (Hz buttons)

Different than the TM262

Page 44: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM286 Test Results•

The Tymp

and Tymp

Reflex test results are automatically

stored in memory when the test sequence ends.•

Audiometric test results are stored in memory when the M+ button is pressed.

Each Tympanometric/Reflex test and full audiogram result is assigned a memory page number in order of sequence obtained

A total of 12 memory pages are available

Page 45: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM286 Use

Tympanometry–

226 Hz probe tone

Acoustic Reflex testing–

Ipsi-lateral reflex screening

Up to 4 stimuli per screen

Audiometry–

Manual or Automated

THD 39 or EAR-3A insert (option) headphones

Data Collection–

Use on-board printer

Optional External Printer

Page 46: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Page 47: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Serial Number

Page 48: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Back Panel

Page 49: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Standard accessories

28209/8000-0177•

Headphones

28601 AND 28602•

Power Module

26100•

variety TM eartips

(6 sizes, 2 each)

Page 50: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Standard Accessories

26241•

Test Cavity

28604•

Auto Tymp

QRG

52600* •

Supplied 3 Rolls

Page 51: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Standard Accessories

28607•

Wall Chart

Page 52: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Standard Accessories - 28202

Page 53: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Installation •

Stand Alone–

Plug power source into unit and into wall

Turn Unit on–

Ensure Paper is loaded correctly and prints a test

Enter Program Mode to set preferences

Computer or Printer Interface–

Use USB cable to connect to a PC or Printer

Establish connection with PC (Page 2 of Program Sub Menu) Greenway Medical, NOAH, etc

Establish connection with Printer (Page 2 of Program Sub Menu) HP OfficeJet

6000 is best

.

Page 54: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Routine Maintenance •

Test Cavity

Biologic Check•

Calibration

Cleaning.

Page 55: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Biologic Check – Tymp/Reflex

Operator performs Tympanogram

on self or known normal ear

Operator performs Reflex Screening on self or known normal ear

Review results –

ensure they are as expected

Page 56: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Biologic Check - Audiometry

Operator listens to headphones•

Changes loudness and pitch

Listen for distortion or other odd sounds•

Make sure it’s working as expected

Page 57: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Calibration

How frequently should the instrument be calibrated?–

One time per year

Any time new headphones are purchased (even if they’re identical replacements)

Headset must accompany device for routine calibration

Page 58: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Cleaning•

Instrument/Headphones–

Wipe with soft damp cloth

Okay to use mild cleaning agent–

Do NOT get any moisture into the speakers of the headphones

Probe –

as needed–

Unscrew probe nose cone

Remove small wire –

use to clear any debris–

Use dust-free cloth –

like KimWipe

to wipe

MUST REPLACE WIRE–

Re-attach probe nose cone

Page 59: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM286 Tympanometry•

Pressure Range and Sweep optimized for accurate and fast measurements

Pressure Range: +200 to -400 daPa–

ECV/cavity limits for initiating pressurization is 0.2 to 6.0 cm3.

Normative Data displayed on screen•

226 Hz probe tone

Pressure sweeps to at least -100 daPa. To save test time, pressure sweep stops when tympanogram

returns to baseline after -100 daPa–

600 daPa/sec except near tympanogram

peak where sweep rate slows to 200 dapa/sec to provide better definition of peak compliance

Page 60: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM286 Acoustic Reflex Testing

Ipsilateral

Reflex Screening•

Total of 4 frequencies for screening

Method–

Stimuli are presented at lowest level first

If there is no response, intensity is increased by 10 dB until a response is detected or the maximum dB HL is reached

Reflex Criteria–

226 Hz: Compliance change of 0.05 cm3 or greater.

Page 61: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

TM286 Audiometry

Manual or Automated testing available–

Can set test parameters in the “program”

menu

Transducers–

TDH39 (standard headphones)

EAR-3A and EAR-5A phones available

Stimulus Choices–

125Hz-8000Hz with an extended range of +10dB

Steady, Pulsed or FM

Page 62: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Optional Accessories

05260-U•

Carrying case

28203•

Insert phones (requires Calibration at factory)

23222•

Audiocups

23220•

handswitch

Page 63: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Optional Accessories

26240•

Dust cover

23221•

Patch Cords Note: 1 cord needed per connection (2 for headset, 1 for handswitch)

52600•

Thermal Paper –

5

rolls

Page 64: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Optional Accessories

Eartips: 25 each•

26008

– 8mm

26011

11mm•

26013

13mm

26015

15mm•

26017

17mm

26019

19mm

26100 –

6 sizes, 2 each

Page 65: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Replacement Parts

8000-0177•

Headset assembly

28210•

Audiometry

y-cord 2

plug shielded

Page 66: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Replacement Parts

Eartips

25 per box•

26008

– 8mm

26011

11mm•

26013

13mm

26015

15mm•

26017

17mm

26019

19mm

26100 –

6 sizes, 2 each

Page 67: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Replacement Parts

26240•

Dust cover

23221•

Patch Cords Note: 1 cord needed per connection (2 for headset, 1 for handswitch)

52600•

Thermal Paper –

5

rolls

Page 68: AM282 Manual Audiometer TM286 Auto Tymp Training

Advancing Frontline Care TM

Welch Allyn Contacts

.

Kim Forbes, US/C Mktg – X2674Melissa Dart, US/C Mktg – X5438