alpha vci.45 system€¦ · 7.vertical l-profile 8.insulation 9.terracotta panel 10.a/v barrier...

13
Page: Revision: 09/2016 01 Alpha Vci.45 System www.ecocladding.com

Upload: others

Post on 19-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

Page:Revision: 09/2016 01

Alpha Vci.45 System

www.ecocladding.com

Page 2: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

Option 2

Option 1

Option 1

Page:Revision: 09/2016 02

Elevation and floor plan

www.ecocladding.com

Outer corner

pg.06

Inner corner

pg.07

Window jamb

option 1

pg.08

Window jamb

option 2

pg.09

Vertical joint

pg.04

Ba

se

d

eta

il

pg

.1

3

Cop

in

g de

tail

pg.1

2

Ho

rizo

nta

l jo

int

pg

.0

5

Win

do

w sill

pg

.1

1

Wind

ow

h

ea

d

pg.1

0

Page 3: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

tD

1

R

23/4 7 6 5 20 21/22 23 910 11 8

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

System depth

Bracket

min. D system depth max. D system depth

R

t panel thickness

Alpha V 035 / Alpha V+ 035

2

7

8

" (73mm)

4" (101mm)

1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 050 / Alpha V+ 050

3

1

8

" (79mm) 4

9

16

" (116mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 080 / Alpha V+ 080

4

5

16

" (109mm) 5

3

4

" (146mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 100 / Alpha V+ 100

5

1

16

" (129mm) 6

9

16

" (166mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 115 / Alpha V+ 115

5

11

16

" (144mm) 7

1

8

" (181mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 135 / Alpha V+ 135

6

7

16

" (164mm) 7

15

16

" (201mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 150 / Alpha V+ 150

7

1

16

" (179mm) 8

1

2

" (216mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 170 / Alpha V+ 170

7

13

16

" (199mm) 9

5

16

" (236mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 185 / Alpha V+ 185

8

7

16

" (214mm) 9

7

8

" (251mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 200 / Alpha V+ 200 9" (229mm)

10

1

2

" (266mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 220 / Alpha V+ 220

9

13

16

" (249mm) 11

1

4

" (286mm) 1

1

32

" (26mm)

11

16

" (18mm)

Alpha V 255 / Alpha V+ 255

11

3

16

" (284mm) 1'-0

5

8

" (321mm) 1

1

32

" (26mm)

11

16

" (18mm)

Page:Revision: 09/2016 03

System depth

www.ecocladding.com

Page 4: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

5

16

"

tD

R

1 23/4 7 6 5 2021/22 2391011 8 24

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Page:Revision: 09/2016 04

Vertical joint

www.ecocladding.com

Page 5: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

t D

5

16

"

R

23

21

20

6

22

5

2

4

7

9

8

10

11

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Page:Revision: 09/2016 05

Horizontal joint

www.ecocladding.com

Page 6: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

D t

5

16

"t

Option 1

R

1 23/4 7 6 5 20 21/2223 910118

12

Option 2

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Option 3

13

Page:Revision: 09/2016 06

Outer corner

www.ecocladding.com

Page 7: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

5

16

"

D t

Option 1

R

21/22232620 7 8 9

5

3/4

10

11

Option 2

24

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Page:Revision: 09/2016 07

Inner corner

www.ecocladding.com

Page 8: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

tD

R

21/22 23 2 6 20 7 58

1

11

10

14

3/4

9

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Page:Revision: 09/2016 08

Window jamb (option 1)

www.ecocladding.com

Page 9: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

tD

5

16

"

5

16

"

R

20 2 3/4 5 789

11

10

1

7

23

21/22

6

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Page:Revision: 09/2016 09

Window jamb (option 2)

www.ecocladding.com

Page 10: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Dt

1" min

of perforation

R

9

3

5

2

7

8

10

11

23

21

20

6

17

Page:Revision: 09/2016 10

Window head (option 1)

www.ecocladding.com

Page 11: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Dt

1

2

"

R

23

21

20

6

9

3

5

2

7

8

10

11

18

Page:Revision: 09/2016 11

Window sill

www.ecocladding.com

Page 12: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

Dt

23

R

21

20

6

9

3

5

2

7

8

10

11

16

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Page:Revision: 09/2016 12

Coping detail

www.ecocladding.com

Page 13: Alpha Vci.45 System€¦ · 7.Vertical L-profile 8.Insulation 9.Terracotta panel 10.A/V barrier 11.Exterior wall 12.Outer corner closure 1 13.Outer corner closure 2 14.Jamb closure

1" min

of perforation

Dt

R

9

3

5

2

7

8

10

11

23

21

20

6

19

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. #12x1 TEKSELECT screw

7. Vertical L-profile

8. Insulation

9. Terracotta panel

10. A/V barrier

11. Exterior wall

12. Outer corner closure 1

13. Outer corner closure 2

14. Jamb closure

15. Horizontal L-profile

16. Coping

17. Perforated window head

closure

18. Window sill

19. Perforated base closure

20. Carrier rail

21. Hanger, adjustable

22. Hanger, non-adjustable

23. S/S adjustment screw

24. Vertical joint closure

D - System depth

t - Panel thickness

R - Carrier rail and Hanger

* Ventilation will vary based on

insulation depth.

** Minimum ventilation

requirement should be

qualified by panelmanufacturer.

*** One of adjustable hangers per

panel to be fixed with structural

silicone

Page:Revision: 09/2016 13

Base detail

www.ecocladding.com