alma band 9 technology for ccat andrey baryshev. ccat 2011 cologne2 alma band 9 group sron a....
TRANSCRIPT
![Page 1: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/1.jpg)
ALMA Band 9 technology for CCAT
Andrey Baryshev
![Page 2: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/2.jpg)
CCAT 2011 Cologne 2
ALMA band 9 groupSRONA. BaryshevB. JacksonR. HesperJ. AdemaF.P. MenaJ. BarkhoffM. BekemaK. KeizerG. GerlofsmaA. KoopsJ. PanmanW. WildTUDelftC. LodewijkT. ZijlstraE. Van ZeijlT.M. KlapwijkNUIMN. TrappeM. WhaleM. CandottiA. Murphy
![Page 3: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/3.jpg)
CCAT 2011 Cologne 3
Outline
• ALMA band 9 technology• Results of >64 ALMA cartridges• Use of ALMA mixers in FPA (CHAMP+)• 2SB mixer technology
![Page 4: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/4.jpg)
CCAT 2011 Cologne 4
Main band 9 specification
• RF band 602-720 GHz• DSB mixing scheme• IF band 4-12 GHz (8 GHz bandwidth)• 4 dB IF pass band ripple• 10-8 relative total power stability @ 1s• Sensitivity integrated over IF: 175 K (80% band)
240 K (20% band)• Dual polarization• -20 dB cross - polarization response• Gain compression within 3% @ 400 K load• Phase stbility • No moving parts• Large amount of receivers
![Page 5: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/5.jpg)
CCAT 2011 Cologne 5
Band 9 cartridge layout
2004 2006
![Page 6: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/6.jpg)
CCAT 2011 Cologne 6
Cartridge Optics Layout
![Page 7: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/7.jpg)
CCAT 2011 Cologne 7
SIS mixer
Simple constructionEasy to assemble
![Page 8: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/8.jpg)
CCAT 2011 Cologne 8
SIS Technology
SIS Junctions (TU Delft)• THz SIS mixers
• quantum-limited sensitivities• 600-720 GHz bandwidth
• LO tuning range• 4-12 GHz IF bandwidth
• 4-8 GHz in HIFI• SIS junctions (TU Delft)
• Nb SIS technology• optimized fabrication
• larger quantities• improved pattern accuracy• 1 µm structures are 1 µm
• waveguide device mounts• optimized for series production
• corrugated horn antennas (RPG)• commercial product• 100 µm structures +/- 5 µm
![Page 9: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/9.jpg)
CCAT 2011 Cologne 9
4-12 Cryogenic isolator
![Page 10: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/10.jpg)
CCAT 2011 Cologne 10
8 cartridges
![Page 11: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/11.jpg)
CCAT 2011 Cologne 11
ALMA 2012
2012!!
![Page 12: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/12.jpg)
CCAT 2011 Cologne 12
Noise temperature #1..#8
610 620 630 640 650 660 670 680 690 700 7100
50
100
150
200
250
300
Average Tnoise
FLO
(GHz)
Tn
ois
e (K
)
pol. 0 (C1)pol. 1 (C1)pol. 0 (C2)pol. 1 (C2)pol. 0 (C3)pol. 1 (C3)pol. 0 (C4)pol. 1 (C4)pol. 0 (C5)pol. 1 (C5)pol. 0 (C6)pol. 1 (C6)pol. 0 (C7)pol. 1 (C7)pol. 0 (C8)pol. 1 (C8)
4 К
![Page 13: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/13.jpg)
CCAT 2011 Cologne 13
Noise temperature for 64+ cartridges
![Page 14: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/14.jpg)
CCAT 2011 Cologne 14
Noise temperature for 64+ cartridges
![Page 15: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/15.jpg)
CCAT 2011 Cologne 15
Tnoise vs LO per junction technology
![Page 16: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/16.jpg)
CCAT 2011 Cologne 16
Tnoise vs IF
![Page 17: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/17.jpg)
CHAMP+: A powerfull sub-millimeter heterodyne array
The GREAT team: MPIfR (PI-Institute)
– C. Kasemann– R. Güsten– S. Heyminck– B. Klein– T. Klein– G. Wieching– H. Hafok– A. Korn– G. Schneider– A. Hänseler– C. Castenholz– H-J Wunsch– F. Schäfer– F. Pacek
Mixer development (SRON)– A. Baryshev (SRON)– T.M. Klapwijk (TU Delft)
![Page 18: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/18.jpg)
APEX
Telescope:Location: Llano de Chajnantor,
northern Chile Coordinates: Latitude : 23º00"20.8' South
Longitude :67º45'33.0" WestElevation : 5105 m
Diameter: 12 mf/D: 8
Beam width:(FWHM) 7.8" * (800 / f [GHz])Main reflector: 264 aluminum panels, average
panel surface rms 5 micronSurface accuracy: 17 micron rms
Pointing accuracy: 2" rms over skyMounting: Alt-AzReceiver cabins: 2 Nasmyth + 1 Cassegrain
Mass: 125 000 kgManufacturer: Vertex Antennentechnik
![Page 19: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/19.jpg)
SIS-Mixers
THz SIS mixers– quantum-limited sensitivities– 600-720 & 780-950 GHz RF-bandwidth– 4-8 GHz IF bandwidth
SIS junctions (TU Delft)– Nb SIS technology (660GHz)
– Nb-NbTiN SIS technology (850GHz)
– optimized fabrication• larger quantities• improved pattern accuracy• high reproducibility
waveguide device mounts– optimized for series production
corrugated horn antennas (RPG)
Mixers assembled to the mixer-mount Mixer electronics with connector-block Magnet block
![Page 20: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/20.jpg)
Control electronics
LO-synthesizer
HEMT-BIAS
Magnet-current
Mixer-BIAS
Temperature monitor
Online UPS
LO-Power
Misc. devices
motor controller
810GHz 660GHz
![Page 21: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/21.jpg)
IF-Processor
• 14 input channels• IF bandwidth 4.625 – 7.475
GHz• 28 output channels
• output 0.05 – 1.55 GHz• individual output attenuator• total power detector
• Allan minimum times > 500s(@ 1MHz resolution)
• temperature stabilized• fully remote controlled
![Page 22: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/22.jpg)
“New” backend: FFTS
Array FFTS (Fast Fourier Transform Spectrometer)
32 backend-channels, each providing•1.5GHz instantaneous bandwidth •8192 spectral channels•to be installed at APEX in the next two weeks
more details: talk 6-7 of B. Klein:“The Next Generation of Fast
Fourier Transform Spectrometer”
“Old” backend:MACS auto-correlator system32 backend channels, each providing•1GHz instantaneous bandwidth•1024 spectral channel•operational at APEX since January 2007
![Page 23: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/23.jpg)
The mixer block - assembly
RF input horn
Magnet coil
LO horn
Standard band 9Mixer backpieceIF
connector
RF structure
Impedance-matchedloads
Deflux heater
SIS junction
Spring-loaded
cap
Centering ring
![Page 24: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/24.jpg)
Block size: 45 x 21 x 53 mm3
RF mixer Block
![Page 25: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/25.jpg)
2SB ALMA Cartridge!!!
25
![Page 26: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/26.jpg)
2SB Cartridge. First tests.
600 620 640 660 680 700 7200
5
10
15
20
25
30
35
Fsignal
(GHz)
Sid
e B
an
d R
ati
o(d
B)
Side band Ratio
620 630 640 650 660 670 680 690 700 7100
100
200
300
400
500
FLO
(GHz)
Tn
ois
e (K
)
Average Tnoise
pol. 1 (+s1+s2)pol. 1 (-s1+s2)pol. 1 (+s1-s2)pol. 1 (-s1-s2)
1) Cartridge prototype – fabricated, works!
2) LO optics designed and approved3) New 4-12 GHz Hybrid successfully
tested
![Page 27: ALMA Band 9 technology for CCAT Andrey Baryshev. CCAT 2011 Cologne2 ALMA band 9 group SRON A. Baryshev B. Jackson R. Hesper J. Adema F.P. Mena J. Barkhoff](https://reader035.vdocuments.us/reader035/viewer/2022062620/5519ed8f550346d67b8b4c15/html5/thumbnails/27.jpg)
CCAT 2011 Cologne 27
Conclusions
• Good performance large series DSB mixers have been demonstrated, base line for CCAT
• These can be used in large focal plane arrays• 2SB mixer for ALMA band 9 has been demonstrated • Ready for CCAT FPA (classical technology) • Many challenges for real CCAT FPA >64 pixels