alc pdh radio technical training(siae microwave)
TRANSCRIPT
ALC1
ALC PDH RADIOTechnical Training
Instructor
Mr. Monthien Satantoranin
Senior Manager Technical Support
ALC2
Training TopicsTraining Topics
1. ALC Equipment Structure2. Installation , Configuration and Operating3. SCT Network Management4. Faults and Alarm Understanding5. Troubleshooting and Looback Test6. Path/Link Calculation
ALC3
ALC Equipment StructureALC Equipment Structure
1. ALC IDU ( Indoor Unit)2. ALC ODU ( Outdoor Unit)3. LIM ( Line Interface Module)4. RIM ( Radio Interface Module)5. Interconnection IDU to ODU cable
ALC4
Mains FeaturesMax capacity : 16 E1 + 3 Ethernet PortIDU size: 1U high only and single boardService channel: optional V11 codirectional. Loops: RF loop, IF loop and Baseband loopsATPC range : depending on frequency (20dB or 40 dB)Internal PRBSIDU-ODU cable: 370 meter of ¼” or RG8
IDU ( Indoor Unit)
ALC5
IDU (Indoor Unit)IDU (Indoor Unit)
21
RXTX
ALTEST
R
USER IN/OUTQ3 LCT
Trib. 13-14-15-16Trib. 5-6-7-8
Trib. 9-10-11-12Trib. 1-2-3-4
PS2
PS1
212
48V2
+ --+
48V1
Fuse: 3.15A (M)
IDU-ODU cable SMA connectors
120ohm E1 Sub-D type connectorsLCT USB
connector
SCT LAN port
PSU alarm LEDs
PSU connector
Tx Rx
1
2
TEST
ALR
Active branch (Tx / Rx)
Manual operation / Loop active
AlarmsReset
ALC6
ODU (Outdoor Unit)ODU (Outdoor Unit)
Volt/dBm in Rx
Reference Tooth
Weight = 4.5 Kg
ALC7
ODU Mounting ODU Mounting
Max.1 dB Loss
ALC8
ALC9
Unprotected ODU
1+1 ODU
1+0 ODU
ODUODU with with Integrated antennaIntegrated antenna
ALC10
Frequency signals:Tx IF 330 MHzRx IF 140 MHzTelemetry IDUODU 17.5 MHzTelemetry ODUIDU 5.2 MHzPower 48 VDC
Max length (1/4 inch or RG 8 cable)4/16QAM 370 m
Interconnection cableInterconnection cable
ALC11
Equipment CompositionEquipment Composition
ALC is made up by different sub-modules housed in two mechanical structures:
1) IDU LIM Controller RIM (one per branch)
2) ODU Radiotransceiver (RT, one per branch)
ALC12
Module functionalitiesModule functionalities
Service interfaces
Management software ports
Equipment controller
EOC
Alarm LEDs
User in / Alarm out facilities
Power supplyCable interfaceModulator (analog side) 330 MHzDemodulator (analog side) 140 MHz
Radio Power supply
Cable interface
IF unit
RF unit: Transmitter, Receiver
Line interfaces
Line Mux-Demux circuits, Service Mux-demux circuits
Bit insertion-extraction,
Modulator - Demodulator (digital side)
Switch management
BER counters
LIM
CONTROLLERRIM
RT
ALC13
Equipment Equipment structurestructure
ALC14
ControllerController
ALC15
LIM LIM Tx directionTx direction)
ALC16
LIM LIM Rx directionRx direction
FEC *
(block code)
errors
*FEC = Forward Error Corrector
Example: Without BER=10-6
With BER=10-13 (+2.5 dB)
ALC17
RIMRIM
ALC18
ODUODU
ALC19
ALALCC characteristics (1) characteristics (1) Tx power (4QAM/16QAM): 7 GHz +27 dBm / +22 dBm 15 GHz +25 dBm / +20 dBm 23 GHz +20 dBm / +15 dBm Tx/Rx spacing: 7 GHz 154/161/168/196/245 MHz 15 GHz 420/728 MHz 23 GHz 1008/1232 MHz Power consumption 1+0 < 30 W 1+1 < 55 W
ALC20
ALC characteristics (2) Rx HBER (10E-3) thresholds (4QAM/16QAM): - in 16x2 7 GHz -84 dBm / -80 dBm 15 GHz -83.5 dBm / -79.5 dBm 23 GHz -83 dBm / -79 dBm - in 4x2 7 GHz -90 dBm / -86 dBm 15 GHz -89.5 dBm / -85.5 dBm 23 GHz -89 dBm / -85 dBm Max Rx power - 20 dBm
ALC21
Installation ,Configuration andInstallation ,Configuration andOperatingOperating
1. IDU, ODU Installation2. SCT :Network Management Software3. LCT :Local Craft Terminal4. Parameter and Configuration5. Alarm Monitoring 6. Backup ,Upload and Download firmware
ALC22
Installation
IDU InstallationPower Supply and GroundingE1 Cable and WiringAntenna and ODU Mounting
ALC23
Installation
IDU Installation (1)USB/LCT
E1
Power Supply
IDU to ODU
Cable
ALC24
Installation
IDU Installation (2)
IDU to ODU Cable
ALC25
InstallationPower Supply and Grounding
Power Supply
-48 to -57.6 Vdc
Nominal Consumption
44 watts (1+0)
24 watts ( IDU only)
ALC26
InstallationPower Supply and Grounding
1= IDU grounding point 5=IDU matching tail grounding
2=ODU grounding point 6=Battery grounding point
3= IDU-ODU interconnect cable 7=Grounding cord connect to Earth ground rod
4=Cable grounding/Station ground
ALC27
InstallationODU Grounding
ALC28
Installation
E1 Cable and Wiring
ALC29
Installation
Antenna and ODU Mounting
ALC30
Installation
Antenna and ODU Mounting
ALC31
InstallationAntenna and ODU Mounting
ALC32
Installation
Antenna and ODU Mounting
ODU final housing position for
Vertical Polarization
ODU final housing position for
Horizontal Polarization
ALC33
Antenna and ODU mounting1 2 3
4 5 6
ALC34
SCT/LCT : Main Features SCT/LCT connection SCT Main Window Menus Routing Stored Routing Table Station management Commang Logger Equipment features management Configuration backup/restore Alarm monitoring LCT Main Window Manus Radio Parameter Configurations
ALC35
SUBNETWORK and LOCAL SUBNETWORK and LOCAL CRAFT TERMINALCRAFT TERMINAL
SCT/LCTSCT/LCT
PERSONAL COMPUTER WITH GRAPHICAL DISPLAYPERSONAL COMPUTER WITH GRAPHICAL DISPLAY
WINDOWS 98, NT, 2000, XP SW PLATFORMWINDOWS 98, NT, 2000, XP SW PLATFORM
TCP/IP COMMUNICATION PROTOCOL USING:TCP/IP COMMUNICATION PROTOCOL USING: RS232 Serial port (COM1/2 + PPP)RS232 Serial port (COM1/2 + PPP) USB +PPPUSB +PPP Ethernet LAN Ethernet LAN
ALC36
““ALC” RADIO IP PROTOCOL STACKALC” RADIO IP PROTOCOL STACK
TCP / UDP
LLC 802.2MAC 802.3
802.3(ETH LAN)
IP / OSPF
ASYN-RS23257.6Kb/s
APPLICATION SOFTWARE
SNMP
EOC (Radio)64Kb/s
P P P
LCTUSB
ALC37
SCT : Connections
C
ALC38
Connection to the equipmentConnection to the equipment
ALC39
Login
User: SYSTEM (read & write) ; RLOM (read only)
Password: siaemicr
ALC40
History log
Equipments inside the stationStations
ALC41
Log as SYSTEM an equipment in monitor
Read again the status of the equipment
User management and time alignment Configuration
upload/download and station management
History log
management
Configuration of the equipment
list of commands
Configuration of the connection
ALC42
SCT Menu-EquipmentSCT Menu-Equipment
ALC43
SCT Menu-OptionSCT Menu-Option
ALC44
SCT Menu-NetworkSCT Menu-Network
ALC45
SCT Menu-ToolSCT Menu-Tool
ALC46
Equipment menuEquipment menu Equipment configuration
Agent, name, time
Alarms, group by group
Alarms’ configuration
Test, loops, manual operations
Firmware update
Performance monitoring
Units
Automatic troubleshooting
Alarms reading (refresh)
Routing and addressing
ALC47
ALC48
PropertiesPropertiesEquipment name
Agent, used in alarm history and in subnetwork wizard
Equipment time alignment and network time alignment
Software restart (doesn’t cut the traffic)
ALC49
View Current AlarmsView Current Alarms
ALC50
Alarm configurationAlarm configuration
ALC51
Manual operations listManual operations list
ALC52
Firmware UpdateFirmware UpdateFirmware Switch
Download of the firmware
Upload of the actualfirmware
ALC53
Download of the new firmwareDownload of the new firmware
Position of the file firmware.dwl
Overwriting of old firmware (total dowload – slow)
Download of different sections only (fast) or towards peripheral (radio)
Bench switch after the download
ALC54
Performance MonitoringPerformance Monitoring
Quality results
Output power
Input power
Start/Stop of selected item
Show of the resultsof the selected item
ALC55
UNITS
Status
Part number Part number
Kind of troubleTrouble severity
ALC56
DiagnosisDiagnosis
Reading the actual alarms the Diagnosis prepares an explanation of every trouble and the procedures to follow to solve the problem
ALC57
Port addressesPort addressesAll SIAE equipments, regarding SCT software and supervision, are routers: all interfaces need an address and relevant subnet mask
Addresses can be set clicking:
1. Set values
2. Store
3. Restart
Client (always)
ALC58
RoutingRouting
ALC59
RoutingRoutingALC Port and Address
ALC60
RoutingRoutingALC Port and Address in daisy chain
ALC61
Routing tableRouting table
Type and address
of crossed port
Type and address of crossed port towards
Destination
Netmask and IP address of Destination
Default destination
ALC62
Stored Routing TableStored Routing TableThe “Stored Routing Table” adds routing lines, after a
Restart, to the running Routing Table of the NE.In this way we can change Ports addresses (operation that
needs a restart) without loosing a remote NE:1. In “Stored Routing Table” add the routing lines
relevant to new port addresses you are going to set2. Set the new port addresses (…the equipment restarts)3. After the restart the equipment has new addresses and
the routing table configured already: the NE management is still running
ALC63
Station managementStation managementNEs connected to SCT can be assigned in
various stations using the tool :“Subnetwork Configuration Wizard”
ALC64
Alarm correlation Alarm correlation Every alarm is reported withAlarm beginning Alarm end (gravity info is maintained)
ALC65
Alarm acknowledgementAlarm acknowledgement
Alarm acknowledge is available inalarm history list: every acknowledgement can be managed completely in station list: new alarm info is highlighted by an asterisk
ALC66
Command loggerCommand loggerCmd Logger reads the list of operations, executed by the users,
stored on the controller of the equipment.The “log”, uploaded from equipment, is stored on the PC for
further consultations. Following filters are available: Operations date User address User type Operation name
ALC67
Configuration upload/downloadConfiguration upload/downloadUpload (from equipment)From Tool menu, open the proper TemplateSelect Upload operation and the equipment you want to upload information fromSave them in a file (*.cfg)
Download (to equipment)From Tool menu, open the proper file (*.cfg)Select Download operation and the equipment you want to download information to
Uploaded parameters and *.cfg file are editable using
Equipment Configuration Wizard.
ALC68
Configuration TemplateConfiguration TemplateConfiguration template: it is relevant to equipment radio parameters as frequency, attenuation, capacity, thresholds,…
Address configuration template: it is relevant to management parameters as port IP addresses, routing tables, remote elements tables, OSPF.
Both configurations are necessary during first installation or when Controller module is substituted with a spare one: you can use a file to download or set every parameter manually.
ALC69
Full backupFull backup
The whole amount of parameters (equipment parameters, address parameters and remote element table) can be uploaded from equipment, saved in a file (*.bku), downloaded to equipment.
These parameters cannot be editated.
ALC70
LCTLCTfor for ALALCC
ALC71
Configuration
BitrateModulation
Link ID (local only)
GeneralGeneral
ALC72
1) General preset:thresholds
HBer,LBer, EWL thresholds
Rx Power Low thresholds
ALC73
2) General preset:Rx switches
1+1
1+0
In case of Hber, Lber, EWL, first CRC correction
In case of no Rx
ALC74
Main parameters of the link are:
Configuration
Capacity
Modulation
Link ID
Frequency
Radio link parametersRadio link parameters
For local terminal
Setting has to be copied in remote terminal
Frequency
Capacity
Modulation
Link ID
Only “Configuration” has to be set locally (on local and after on remote)
For both local and remote terminal
ALC75
PRBS (Pseudo Random Bit Sequence)Alarm on “Checked signal” lineMeasure results and duration
Tributary selection if checked is Signal 2MBit
P.R.B.S replaces the traffic on selected channelP.R.B.S. test is pointed out as Manual Operation (subject to timeout)
Checked signal selection
Measure status
Pattern type
Sync Los events during test
ALC76
ATPC ATPC (Automatic Tx Power Control)(Automatic Tx Power Control)
ALC77
ATPC CharacteristicsATPC Characteristics
Maximum ATPC range: This range is limited by the amount of fixed attenuation with respect to the nominal TX power
Power Control Criteria: Remote terminal Received Signal Level (RSL) and BER
ATPC speed: 30 dB/s
Purpouse: To counteract the effect of flat fading, minimizing nodal interferences
ALC78
MaintenanceMaintenance
1. Reriodical Check2. Alarm Meaning3. Root Cause of Failure4. Troubleshooting 5. Loop Facilities
ALC79
Periodical Checks are used to check for radio equipment operation without the presence of any alarm conditions
Periodical Check
Check of the TX Power
Check of the Receive Signal Strength
( Reading Value must be match with link hop Cal.)
Check of BER and HOP performance
ALC80
Normal operating conditionNormal operating condition
Rx level on both ODU match values given by hop calculation.
Rx level accuracy: -40 dBm -75 dBm range ± 3dB -30 dBm -40 dBm range ± 4dB
ALC81
Faulty condition: alarm notificationFaulty condition: alarm notificationA faulty condition is pointed out byIDU front panel LEDs:
- AL: alarms, internal or external- TEST: manual operation active
SCT window:- Log history area (with alarm correlation)- Equipment view current alarms (with alarms grouping)
ALC82
ALARMSThere are two directions of alarms: Tx and Rx
Tx – This line starts in LIM and arrives to output flange: when a situation of more alarms is occurring, the most significative alarm of them is at the beginning of Tx chain, all the others after are due to this
Rx – This line starts in output flange and arrives to LIM: when a situation of more alarms is occurring, the most significative alarm of them is at the beginning of Rx chain, all the others after should be caused by this
Most Significant alarmRx
Tx
RIM
LIM
ODU
LIM
RIM
ODU
ALC83
COMMON group
Alarms not related to a specific part of the equipment but relevant to the link.
Example:.
– EOC radio alarm (relevant SCT management)– Link telemetry fail (relevant traffic, ATPC info, man op)
If both alarms are ON, the link is interrupted. Investigation must be made on a possible condition of bad
propagation, or equipment failure
ALC84
ALC85
No link between Local and Remote station. Traffic is cut.
Link telemetry is inserted in main radio frame in Bit Insertion circuit inside LIM, and contains commands for the remote station: switch off the radios on remote side in case of local RF loop, Link ID, ATPC info.
Telemetry link is a connection between local and remote IDUs.
TEST - if this alarm occurs, a double IDU loop (both branches) can be done: if this alarm disappears, local IDU is OK and the problem is after (propagation, local radios, remote equipment).
Link telemetry fail
ALC86
Communication Radio EOC Data link
No link between Local and Remote station or wrong port address configuration.
EOC is the channel involved in management communication.
If EOC radio link is active:
- Traffic is OK
- Management is cut (no remote)
ALC87
PRBS FailWhen PRBS is working and no signal is received on checked signal, in PRBS window the field Sync Los Alarm is active together with PRBS Fail in Current alarms window
Every ON-OFF transitionincreases the field
PRBS Fail Alarm Counter
ALC88
Communication 2Mb EOC Data link
No EOC channel is present on selected tributary in selected timeslot : wrong port address configuration or no tributary input (LOS). EOC is the channel involved in management communication.
If EOC 2Mb link is active:-Management is cut (no remote)- If relative LOS is active, traffic on that tributary is cut
ALC89
Revertive
When a branch is declared preferential, the switch on opposite branch gives Revertive alarm.
The return to preferential branch, when available again, happens after “Wait Time” period.
ALC90
2Mb/s G.704 (Trib.x) Radio Fail/AIS and/or Line Fail/AISWhen management messages come via tributary timeslot, further checks are performed on both directions of this tributary
ALC91
Tx FailTx Fail
When on remote side both radios don’t receive, on local side a Tx switch command is performed and Tx fail alarm is enabled.
When this alarm is on,check local ODU in stand by
This functionality is enabledin LCT – General PresetThe alarm remains activeuntil Reset is given
ALC92
Link IDLink IDAlarm is on if Link ID check is enabled (Link ID 0) and remote Link ID is different from the local one.
Traffic is cut but signal is received and measured. Output = AIS
This alarm causes:
ALC93
LIM groupLIM group
These alarms come fromExternal fault: tributary LOSLIM failure: -Multiplexer/demultiplexer failure -Modulator/demodulator failure Warning: modulator/demodulator
circuitry is spread into LIM and RIM modules.
RIM or ODU alarms propagation (seen in LIM as Baseband RX alarm)
ALC94
ALC95
Tributary-1 Signal loss
Loss Of Signal alarm is active when a situation opposite to that foreseen by configuration is performed on tributary interface:
No input oror
cable disconnected
Tributary connected
TRIB. STATUS
Tx
ALC96
Multiplexer fail
The alarm is given during multiplexing of input tributaries by
Overflow stuffing memories
Overflow is due to bad clock of one tributary (too fast: >+50ppm) or hardware failure
In case of Multiplexer Fail the signal forwarded to the radio is N x AIS (from all the N tributaries)
Tx
ALC97
Branch-x Modulator Fail
This alarm is active when at cable interface Tx IF modulated signal (330 MHz) is missing or is under a certain value; this is due to: Modulator faulty
Cable IDU-ODU open (that produces high VSWR value)
Traffic is cut
Tx
ALC98
Branch-x ODU-IDU Communication fail
This alarm occurs when on carrier used to receive information from ODU, or remote commands from other side, are detected:
CRC errors
Loss of frame
This carrier is separated from carrier used for opposite direction (IDUODU) and from TX or RX carriers
ALC99
Branch-x Demodulator Fail
Traffic is cut
This alarm is active when average deviation of symbol recognition is higher of a certain level.
Every problem in constellation gives Demodulator alarm: Problem of digital conversion of received signal from RIM I or Q signal missing High level of interference (bad quality but good Rx level) No Rx IF modulated signal (140 MHz) from ODU (no Rx, ODU faulty, IDU/ODU cable open)
Demodulator alarm causes:
Rx quality alarms (HBER, LBER, EWL) Rx signal alarms (BaseBand Rx)
Rx
Branch Rx quality alarm (software settable)
ALC100
Branch-x BaseBand RxThis alarm is active when
Bit Extraction does not work (in LIM)
Demodulator does not work (in LIM)
Demodulator does not receive from RIM or ODU
BaseBand Rx causes:
Demultiplexer Fail
Traffic is cut
Rx
ALC101
Demultiplexer Fail
The alarm is given during demultiplexing by:
Frame Alignment Word not recognised (LOF - loss of frame)
Overflow destuffing memories
Overflow memories of hitless Rx switch
BaseBand Rx alarm
In case of Demultiplexer Fail, output is AIS (from all the tributaries)
Rx
ALC102
RIM group
These alarms come from External fault: demodulator fail alarm and
ODU alarm are generated when ODU becomes faulty
RIM failure: PSU alarm with cable open/short alarm or modulator/demodulator alarms are active
Warning: modulator/demodulator circuitry is spread into LIM and RIM modules.
ALC103
ALC104
Branch-1 Power SupplyThis alarm is active when the PSU (Power Supply Unit) of one
RIM is switched off or is in failure condition
If the PSU is off, all the alarms of that RIM are activated:this alarm causes allRx Branch-1 alarms except those relevantRadio1 (is OFF)
Analysis order is:
PSUAll alarmedfrom now on
RT
IDU
ALC105
Branch-1 Cable open/shortThis alarm is active when the following situations occur:- Cable open alarm no current through cable interface: ODU is not supplied… so situation looks like PSU alarm (Rx alarms) with cable alarm instead PSU alarm- Cable short alarm overcurrent/low voltage through cable interface
Caused by high VSWRvalue of damaged cable
Cable opensituation
If both alarms are active, 48 V source has no enough current
ALC106
RT group
These alarms come fromExternal fault: Rx power low alarm is
generated because of bad propagation or by remote terminal faulty
ODU failure: PSU fail alarm or RF VCO alarm or RF IF alarm is activated
ALC107
ALC108
Branch-x IDU-ODU Communication fail
This alarm occurs in ODU when on carrier used to receive command from IDU, are detected:
CRC errors
Loss of frame
This carrier is separated from carrier used for opposite direction (ODUIDU) and from TX or RX carriers
ALC109
Branch-1 RT Radio Power Supply
This alarm is active when the Power Supply section of the radio doesn’t work properly or is in failure condition (voltage in input out of range).
Depending voltage value, radio can work.
When the under/over voltage is too high, radio is off and other alarms (cable open) cover this.
ALC110
Branch 1 RT VCO fail
This alarm occurs when VCO in RF unit is not able to lock any frequencies.
Every problem in VCO causes alarms in both directions: RF unit is not able to convert IF Tx in RF Tx (Tx Power Low alarm) and RF Rx in IF Rx .
In this situation the alarm is active together with Tx Power Low and all Rx alarms because RF channel is not locked.
Tx & Rx
ALC111
Branch 1 RT If fail
This alarm occurs when is not present IF signal inside ODU. There are two different IF signals but one alarm only.
No IF Tx : the alarm is on and causes Tx Power Low
No IF Rx: the alarm is on with all Rx alarms
Rt If fail can be caused by Modulator fail (no IF Tx)
When VCO is faulty, RF unit gives a IFRX signal made up of noise: this is enough to mantain IF fail alarm off (but Demodulator cannot work Rx alarms).
ALC112
Branch 1 RT Tx Power LowThis alarm occurs when Tx power is 3 dB under standard output of ODU-RF unit.
ATPC and manual attenuation do not affect this alarm that is due by internal failure of RF unit.
This alarm can be activated by a manual operation also: Tx Transmitter off in Radio Branch - Settings
If both Rx Power Low and Tx Power Low are active, RF unit inside ODU is faulty
Tx
ALC113
Branch 1 RT Rx Power LowThis alarm occurs when Rx power is under a defined threshold (about 10 dB under standard Rx level)
Threshold value can be set for both branches in range - 40 dBm- 99 dBm in LCT - General preset
The alarm Rx Power Low is a branch alarm and it is used to drive Rx switch
Rx
ALC114
UNIT group
This group generates alarms when one of the units, the equipment consists of, is faulty or does not respond to controller polling:
Unit failUnit is not respondingUnit is missingUnit hardware mismatchUnit software mismatch
ALC115
ALC116
OTHERALARMS
ALC117
Performance alarmsEvery performance measure can drive the relevant alarm if threshold is exceeded.
Threshold in sec. relevant 15 minutes alarm
Threshold in sec. relevant 24 hours alarm
Threshold in dB of Rx alarm
alarm counter reset
15 minutes alarms severity
If 0, alarm is disabled
ALC118
Performance monitoring
15 min.
alarms
24 hours
alarms
P RX > -5
5 dBmPRX < -70 dBm
R = 15 minutes
ALC119
Recorder : Prx
date time dBm
LCT
ALC120
Measures“Performances” is a group of measures, 15 minutes by 15 minutes, day by day, recorded by the equipment itself and downloaded on the PC (the download needs bitrate).
These measures remain active also with SCT (and PC) disconnected.
“Recorder Prx “ is the recording of Rx power on a log file inside the PC: every time a new value is measured a new “record” is written inside the log file with info of when (day, hour, minutes and seconds) and how much (dBm measured).
This recording remains active until SCT is connected to the equipment.
ALC121
Current AlarmsCurrent Alarms
ALC122
Switch modesSwitch modes Auto Preferential: operator can select which branch must be
operative without alarms. Wait Time = time before coming back to the preferential
branch when alarms disappear. In this way the controller doesn’t switch continuously in case of fleeting alarms.
Reset = Wait Time is not respected Full auto: both branches have same priority
Manual forcing Operator can select which branch must be operative
despite alarms
ALC123
Tx switch criteriaTx switch criteria1. RIM PSU alarm2. Manual forcing3. Cable short/ Cable open alarm Modulator failure ODU unit failure alarm VCO failure alarm IF unit alarm
ODU PSU alarm Tx power low alarm4. Rx failure on both remote radios 5. Revertive Tx
Highest priority
lowest priority
ALC124
Rx switch criteriaRx switch criteria1. RIM PSU alarm2. Manual forcing3. Cable short/open alarm
Base band unit failure alarm Demodulator failure ODU unit failure alarm VCO failure alarm IF unit alarm
ODU PSU alarm High BER alarm (selectable: BER>10-3,-4,-5)4. Low BER alarm (selectable: BER >10-6,-7,-8) 5. Early warning alarm (selectable: BER >10-9,-10,-11,-12) 6. RF input low (selectable from -40dBm to -99dBm)7. CRC pulse8. Revertive Rx
Highest priority
lowest priority
ALC125
EQUIPMENT FEATURE MANAGEMENT
ALC126
LOOP FACILITIES
Local Tributary Loop : used to test the cable interfacing
for the equipment upstream
Remote Tributary Loop : used to test two direction link
performance making use of an unused 2 Mbit/s signal
Baseband Loop : it permit to test the LIM circuits
IDU Loop : it permit to test the complete IDU (optional)
RF Loop : it permit to test the complete radio terminal
ALC127
MU
X-D
EM
UX
RF
E1 LOOP
BASEBAND LOOP
IDU LOOP
RF LOOP
LIM
RIM 1 ODU 1
AL : available loops data direction: - towards the equipment that has enabled the loop (baseband, IDU, RF) - selectable for E1 loop - only local loops
MOD- DEMOD
LOOPSLOOPS
MUX-DEMUX
RF
E1 LOOP
BASEBAND LOOP
IDU LOOP RF LOOP
LIM
RIM 1 ODU 1
AL : available loops data direction: - towards the equipment that has enabled the loop (baseband, IDU, RF) - selectable for E1 loop - only local loops
MOD- DEMOD
Line side
Radio side
Branch 1
BASEBAND LOOP
ALC128
ALC loop:ALC loop:external PRBSexternal PRBS
E1 loop line side : loop works with line enabled or not
E1 loop radio side : loop works with line enabled on local side and on remote side
Base Band, IDU, RF loop : loop works if line used is enabled local side and on remote side
Line side Radio side
ALC129
looploopss::internal PRBSinternal PRBS
E1 loop line side: it is before PRBS checking pointE1 loop radio side: loop works with line enabled on
remote side, indifferent* on local side.Base Band, IDU, RF loop: loop works any status of
local* and remote line__________________________________________________________ * PRBS enables automatically the local side of used line
Alarm OFF: signal is back!
ALC130
Propagation LinkPropagation Link
fLLogdBAfs 2044.92Free space loss (L in Km, f in GHz)
Received power dBGdBGdBAdBmPdBmP RTfsTR
LPT PR
h
E.I.R.P = Pt + Gt+ Cable loss
ALC131
AntennaAntenna
2
22
10D
LogGAntenna gain
D
D = antenna diameter
= wave lenght = c/f
= Aeff / Ageo= antenna efficiency 0,6
c = speed of light = 18103 ms
ALC132
1) Refraction1) Refraction
k < 4/3 (sub-standard)
k = 4/3 (standard)k > 4/3 (super-standard)
Snell law: 2211 sennsenn 1
2
n1
n2
n1
n2
n3
n4
ALC133
2) h2) hgeogeo …earth is not flat…earth is not flat
hgeo
R0 = 6378 km
L
0
2
R
Lhgeo
0
2
Rk
Lhgeo
with k<4/3 , k=4/3 , k>4/3 considering the troposphere refraction (previous page)
considering geometrical visibility on a planet with no air
ALC134
3) First Fresnel zone3) First Fresnel zone
RM
2
LRM
L
A nth fresnel zone gives in phase contributes to radio waves propagation.
In order to avoid attenuation is important that first fresnel zone is without obstacle: to tower height calculation, must be add the ray of biggest Fresnel zone, the first zone
ALC135
Height of the towersHeight of the towersWe have to consider:
earth’s curvature
k effect (refraction)
first Fresnel zone free
From the first we obtain hgeo , with refraction hgeo becomes
and from the last we have to add also RM
geoh
20
2 L
Rk
LRhh Mgeotower
ALC136
exampleexampleL = 20 km
f = 23 GHz
k = 4/3
R0= 6378 km
mkmR
Lhgeo 47047.0
333.1 0
2
+
mL
RM 1.82
htower= 47m + 8.1m = 55.1m
ALC137
Fade MarginFade Margin…from previous page: 4QAM/16x2
L = 20 km PT= +20 dBm
f = 23 GHz HBER - 82 dBm
dBfLLogdBAfs 7.14526.5344.922044.92)(
x = gain of antennas
dBGdBGdBAdBmPdBmP RTfsTR
FM= PR-HBER PR= -82dBm + 40dB = -42dBm
FM = 40dB (purpouse)
GT+GR= 2G = PR-PT+Afs= -42dBm-20dBm+146dB=84dB
GT=GR=42dB D=60cm G=40dB D=80cm G= 42,6dB
ALC138
Rain attenuation (f > 8GHz )Rain attenuation (f > 8GHz )
freq \ rain 25 mm/h 100 mm/h
10 GHz 0.5 dB/km 2.5 dB/km
15 GHz 1.5 dB/km 7 dB/km
20 GHz 2.1 dB/km 10 dB/km
30 GHz 4 dB/km 15 dB/km
40 GHz 6 dB/km 20 dB/km
ALC139
Rain depolarizationRain depolarization
Wind
Drag (air resistence)
Drop weight
E
Hvertical polar. e.m. wave
E
H
horizontal polar. e.m. wave
I
GHz
hv
ALC140
MultipathMultipath
Indirect ray, depending on its phase, can increase or decrease the power of the main stream
Two rays model )(1 jebH
Direct ray: amplitude = Indirect ray: amplitude = b , phase delay = , time delay =
Direct ray
Indirect ray
A B
In B position, received signal has a notch every 1/ Hz with deepness depending on b
ALC141
THANK YOU