42
HUMIDITY ALARMS & INDICATION RAD-1 | p. 66 51XBR Series | p. 69 AIS | p. 65 MNST/MST1 | p. 92 Series 869/869STR | p. 67 ST120 Series | p. 90 ALARMS & INDICATION P il l a Electrical Products, Inc. P il l a Electrical Products, Inc. Kele Offers Custom Assemblies and FREE Display Calibrations.

Upload: ta-mere

Post on 05-Sep-2015

236 views

Category:

Documents


8 download

DESCRIPTION

Kele Alarm & Indication Stations

TRANSCRIPT

  • HU

    MID

    ITY

    ALARMS & INDICATION

    RAD-1 | p. 66

    51XBR Series | p. 69

    AIS | p. 65

    MNST/MST1 | p. 92 Series

    869/869STR | p. 67

    ST120 Series | p. 90

    AL

    AR

    MS

    &

    IND

    ICA

    TIO

    N

    PillaElectricalProducts, Inc.PillaElectricalProducts, Inc.

    Kele Offers Custom Assemblies and FREE Display Calibrations.

  • MODEL/SERIES PAGEProducts manufactured in the United States

    Products that are new to the catalog

    ke le .com

    200 Class | p. 80 ClearView

    ESM Series | p. 86

    ESP Series | p. 88

    ALARMS & INDICATIONA

    LA

    RM

    S &

    IN

    DIC

    AT

    ION

    Alarm and Indication StationsAIS Kele Alarm Indication Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65RAD-1 Kele Remote Alarm Indication Station . . . . . . . . . . . . . . . . . . . . . . . 66

    Emergency Operator StationsE-Stop ESB Series Operator Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84E-Stop ESM Series Emergency Operator Stations . . . . . . . . . . . . . . . . . . . 86E-Stop ESP Series Emergency Operator Stations . . . . . . . . . . . . . . . . . . . 88ST120 Series Operator Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90WPS Series Plate Mounted Operator Stations . . . . . . . . . . . . . . . . . . . . . . . 91MNST and MST1 Series Power Control Stations . . . . . . . . . . . . . . . . . . . . 92

    Loop Powered IndicatorsVPI Series 3-1/2 Digit LCD Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . 93SGD-24, -28 PanelPilot Smart Graphical Display . . . . . . . . . . . . . . . . . . . . . 94BDR Series Kele Big Display Readout, 3-1/2 Digit LED, Red / Blue /

    Green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96LPI-1C 3-1/2 Digit LCD Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97LPI-1C-A, LPI-1C-G, LPI-1C-R 3-1/2 Digit LCD Amber / Green / Red

    Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98LPI-3C, LPI-3C-A, LPI-3C-G or LPI-3C-R 4-1/2 Digit Black / Amber /

    Green / Red Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99LPI-4 Kele 3-1/2 Digit Large Black / Red / Green / Amber Panel Display . . 100LPI-5 Kele 3-1/2 Digit Small Black / Red Panel Display . . . . . . . . . . . . . . . 101

    Multi-Status Indicators105XBRi Series XTRA-BRITE LED Multi-Status Indicator . . . . . . . . . . . . . 76125XBRi Series XTRA-BRITE LED Multi-Status Indicator . . . . . . . . . . . . . 78

    Run Time AccumulatorALD-1 Pulse or Run-time Accumulator Display . . . . . . . . . . . . . . . . . . . . . 102

    Strobes and Horns125STR, 89STR, 869STR, 869, 868STR, 868 Strobes & Horns . . . . . . . . . 67SC-Series Alarm Horn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68STB, STB-H Wall-Mounted Strobe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6851XBR Series XTRA-BRITE LED Beacon with Horn . . . . . . . . . . . . . . . . . . 6957 Series Polaris Class LED Beacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7094 Series Polaris Class LED Beacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71107XBR Series XTRA-BRITE LED Hazardous Location Beacon . . . . . . . . 72105XBRM Series XTRA-BRITE LED Adverse Location Visual Signals . . . . 74125XBR Series XTRA-BRITE LED Beacons . . . . . . . . . . . . . . . . . . . . . . . . 75

    Tower Lights200 Class ClearView LED Stacklight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80TWS Series 75 mm Tower Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

  • NEW!

    65

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

    Supply Voltage 24 VAC/ VDC, 120 VAC, 100 mA max

    Contact Rating AIS-24D 24 VDC, 50 mA min AIS-24A 24 VAC, 90 mA min AIS-120A 120 VAC, 70 mA minAlarm Horn 80 dbDimensions 7 .09"H x 4 .33"W x 3 .54"D

    (18 .0 x 11 .0 x 9 .0 cm)Mounting Four screws through back Enclosure Polystyrene, impact resistant,

    knock-outsApprovals RoHSWeight 1 .1 lb (0 .5 kg)Warranty 1 year

    KELE ALARM INDICATION STATION

    DESCRIPTIONThe Model AIS Alarm Indication Station features an indication light, alarm horn and an alarm horn silence switch .

    FEATURES Long lasting, red LED indication Distinct continuous audible tone Horn silence switch Compact and rugged design Available in 24 VDC, 24 VAC, or 120 VAC Bright yellow panel face

    Power Supply*

    Controlling Device 4 3 2 1(+)(+) ()()

    L

    H

    S

    (Alarm initiated bycontact closure)

    Red LED Light

    Alarm horn, 80 db

    Alarm HornSilence Switch

    * Power must be supplied to the AIS

    AIS

    1

    2

    3

    4

    5 N.C.

    Four-wire connection

    Two-wire connection

    Power supply24 VAC/VDC or 120 VAC

    Remote alarm deviceAlarm initiated bycontact closure

    A power interrupt or open alarm contactwill reset the AIS to normal.

    A power interrupt or open alarmcontact will reset the AIS to normal.

    AIS internalterminal strip

    1

    2

    3

    4

    5 N.C.

    Power supply24 VAC/VDC or 120 VAC

    Remote alarm deviceAlarm initiated bycontact closure

    AIS internalterminal strip

    N.C.

    N.C.

    N.C.=no connection

    N.C.=no connection

    WIRING

    APPLICATION Refrigerant leak alarm indication Water level alarm indication Pressure alarm indication High/Low temperature limits Gas leak indication Humidity limit alarm indication Vibration limit Voltage/Current level limit Any contact closure alarm application

    SEQUENCE OF OPERATIONUpon an alarm contact closure, the LED indicator will light, and the horn will sound . The horn can be silenced through the alarm silence switch, while the visual indication will continue to be lighted until the alarm condition has been corrected . A power interruption or open alarm contact will reset the AIS .

    SPECIFICATIONS

    ORDERING INFORMATION

    MODEL DESCRIPTIONAIS Alarm indication station 12VD 12 VDC powered 24D 24 VDC powered 24A 24 VAC powered 120A 120 VAC powered

    Example: AIS-24A 24 VAC powered alarm indication stationAIS 24A

    March 2014

  • ALARMS & INDICATION

    66

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

    NEW!

    Supply Voltage 24 VAC @ 100 mA or 24 VDC @ 34 mA

    Alarm Delay Time None, or 1 to 31 seconds in one-second increments, or 10 to 310 seconds in 10-second increments

    Alarm Horn Continuous or pulsed tone, 70 db min

    Alarm Repeat Time None, or 1 to 7 in one-minute increments, or 10 to 70 minutes in 10-minute increments

    Alarm Status Relay SPDT, 0 .5A @ 24 VAC, 1 .0A @ 30 VDC

    Connections Screw terminals, 22 - 14 AWG wires Dimensions 4 .5"H x 2 .75"W x 1 .0"D

    (11 .4 x 7 .0 x 2 .5 cm)Mounting Brushed stainless steel plate mounts

    to standard single junction box, two screws provided

    Approvals RoHSWeight 0 .19 lb (0 .07 Kg)Warranty 18 months

    DESCRIPTIONThe RAD-1 is a wall mounted remote alarm indication station mounted on a stainless steel plate . Any contact closure alarm initiating device that can switch 24 VAC or DC can be used with the RAD-1 .

    FEATURES Red alarm LED Alarm horn, continuous tone or pulsed Alarm horn silence switch Adjustable alarm delay time Adjustable alarm repeat time Alarm status SPDT relay Relay operates with the alarm horn option

    8

    7

    6

    5

    4

    3

    2

    1

    ON OFF

    16

    1

    Repeattime inminutes

    (add)

    Repeattime in

    seconds(add)

    HORN PULSED

    REPEAT TIME x10

    DLY TIME x10

    Relayfollowshorn

    Alarm Repeat after Silence Time*SW6SW8 OFF = No delaySW6 ON = 1 minuteSW7 ON = 2 minutesSW8 ON = 4 minutesInitial Alarm Delay Time*SW1SW5 OFF = No delaySW1 ON = 1 secondSW2 ON = 2 secondsSW3 ON = 4 secondsSW4 ON = 8 secondsSW5 ON = 16 seconds

    RAD-1

    24VAC/VDC

    Relay Alarmrelay

    +

    NO

    COM

    NC

    NO

    COM

    NC

    +

    Alarm initiatingdevice

    No jumper Jumper installed

    * Times are additive; for example, with SW3 and SW5 both ON, 4 sec + 16 sec = 20 sec delay (or 200 sec if DLY TIME x10 jumper is installed)

    Initial alarmdelay time x1

    Continuous horn Pulsed horn

    1

    2

    4

    2

    4

    8

    Alarm repeatafter silencetime x1

    Alarm repeatafter silencetime x10

    Inital alarmdelay time x10

    WIRING

    SEQUENCE OF OPERATIONWhen 24 VAC or VDC is applied to the RAD-1 through an alarm-initiating device, the red alarm LED will light, the horn will sound, and the alarm status relay will energize . If an initial alarm delay has been set, when 24 VAC or VDC is applied, the red alarm LED will blink until the delay period has expired . Then it will light continuously, the horn will sound continuously, and the relay will energize . If power is interrupted, the RAD-1 will reset to normal state .

    During an alarm (24V applied to the RAD-1), the horn may be silenced by momentarily pressing the silence switch . The alarm LED will remain lighted, and the alarm status relay will remain energized when the horn is silenced until the alarm condition is cleared (24V removed) . If an alarm repeat after silence time has been set, the horn will re-sound at the end of the repeat time . If the relay-follows-horn jumper is installed, the alarm status relay will de-energize when the horn is silenced and re-energize when the horn sounds at the end of the repeat-after-silence time .

    If a pulsed (instead of continuous tone) horn is desired, the horn-pulsed jumper may be installed . If both the horn pulsed jumper and the relay-follow-horn jumper are installed, the alarm status relay will energize and de-energize with the pulsed horn .

    KELE REMOTE ALARM INDICATION STATIONRAD-1

    SPECIFICATIONS

    ORDERING INFORMATION

    MODEL DESCRIPTIONRAD-1 Remote alarm indication station

  • NEW!

    67

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

    NEW!Supply Voltage N5 (89, 869, 868) 120 VAC AQ (89, 869, 868) 24 VDC, 24 VAC 120A (125STRH) 120 VAC -20% to +10% of nominal

    voltageCurrent Rating 125STRH 120 mA Horn/Strobe 24 VDC, 22 mA/390 mA 24 VAC, 72 mA/390 mA 120 VAC, 24 mA/87 mAAverage Candela Amber 90 cd Blue 20 cd Clear 150 cd Green 70 cd Red 21 cdColor Amber, blue, clear, green, redHorn Loudness 90 dba @ 10'Peak Candela 300,000 cdStrobe Tube Life 3,000 hrs, 1,000 hrs

    Operating Humidity 868, 868 STR 95% RH @ 86F (30C) 869, 89 STR, 869 STR 85% RH @ 86F (30C)Operating Temperature 868, 868 STR -31 to 150F (-35 to 66C) 869, 89 STR, 869 STR 32 to 120F (0 to 49C)Dimensions 89 STR 5"H x 3-3/8"W (12 .7 x 8 .6 cm) 869 STR, 868 STR, 869, 868 5-1/2"H x 5-1/2"W (14 x 14 cm), Enclosure Rating 125 STRH NEMA 4XMounting 868 Weatherproof surface box supplied

    no NEMA rating 869 3" sq x 1-1/2" electrical box with 1-1/2"

    extension ring (need 3" depth)Approvals UL 1638 listed, cULWarranty 2 years

    DESCRIPTIONSignal strobes and horns available in wall-mount and panel-mount configurations with a variety of colors and voltages . Model 125STR is a 120 VAC panel-mount strobe in NEMA 4X enclosure . Model 89STR mounts on a single-gang box and is a single, indoor, flush-mount strobe . Model 869STR is an indoor, flush-mount horn and strobe combination . Model 869 is an indoor, flush-mount horn only . Model 868 STR is an outdoor, surface-mount horn and strobe combination . Model 868 is an outdoor, surface-mount horn .

    FEATURES Indoor and outdoor applications Amber, blue, clear, green, and red colors 24 VAC, 24 VDC, and 120 VAC Surface and panel mount

    868 STR/869 STR Horn/Strobe

    Strobe Horn

    +

    +

    WIRING

    STROBES & HORNS125STR, 89STR, 869STR, 869, 868STR, 868

    SPECIFICATIONS

    ORDERING INFORMATION

    868STR B AQ Example: 868STR-B-AQ Outdoor surface- mount electronic horn with blue strobe and 24 VAC/VDC

    MODEL DESCRIPTION125STRH Panel-mount strobe89STR Indoor flush-mount strobe869STR Indoor flush-mount electronic horn/strobe868STR Outdoor surface-mount electronic horn/strobe869 Indoor flush- or panel-mount electronic horn868 Outdoor surface-mount electronic horn COLOR A Amber B Blue C Clear G Green R Red SUPPLY VOLTAGE AQ 24 VAC/VDC (89, 869, 868) N5 120 VAC (89, 869, 868) 120A 120 VAC (125STRH only)

    869 869STR

    868STR 125STRH

  • ALARMS & INDICATION

    68

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

    NEW!

    Supply Voltage 20-31 VDC (24 VDC nominal)Current Rating STB 80 mA at 24 VDC STB-H 136 mA at 24 VACStrobe Frequency 1 HzHorn Loudness 104 dB maxStrobe Intensity 15 (off-center) candela 75

    (on-center) candelaOperating Temperature 32 to 120F (0 to 49C)Dimensions 4 .5"H x 4 .56"W x 2 .25"D (11 .43 x 11 .58 x 5 .72 cm)WeightSTB 1 .0 lb (0 .45 Kg)STBH 1 .1 lb (0 .5 Kg)Approvals UL Listed File S3406Warranty 3 years

    Supply Voltage SC110 30-120 VAC/VDC SC628 6-28 VDC SC628A, AN 6-28 VAC/VDCCurrent Rating SC100 6-21 mA SC628 3-18 mA SC628AN 4-30 mA SC628A 6-23 mAHorn Loudness Medium, 68-80 dB

    (AN model Loud, 80-95 dB)Tone ContinuousPanel Cutout Panel, cutout 1 .13" (2 .87 cm)Weight 0 .1 lb (0 .05 Kg)Approvals UL recognized component File# S1290Warranty 1 year

    ALARM HORNSC-SERIES

    DESCRIPTIONThe SC Series Alarm Horns provide an audible tone when an electric signal is applied . They can be used in applications when an audible alarm is needed to indicate that immediate attention is required .SPECIFICATIONS

    ORDERING INFORMATIONMODEL DESCRIPTIONSC110 Alarm horn, 120 VACSC628 Alarm horn, 24 VDCSC628A Alarm horn, 24 VAC/VDCSC628AN Alarm horn, 24 VAC/VDC

    WALL-MOUNTED STROBESTB, STB-H

    DESCRIPTIONThe Model STB and STB-H wall-mounted strobes provide a bright, eye-catching warning light for any alarm application . The STB-H features a distinct audible signal .FEATURES Wall mounted with 4" square or double-gang box Integral alarm horn (91 db) 24 VDC powered 15/75 candela strobe intensity Meets requirements of ADA4.28.3 UL listed Xenon strobe for constant flash rate Strobe and horn powered separately if desired Jumper-selectable, continuous or temporal tone

    SPECIFICATIONS

    ORDERING INFORMATIONMODEL DESCRIPTIONSTB Wall-mounted strobeSTB-H Wall-mounted strobe with horn

    WIRING

    WIRING

    SC Horn

    Horn+

    Note: Switch 1, 2 off

    Signal

    ++

    S+ S+ S- H- H+

    March 2014

  • NEW!

    69

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

    NEW!

    DIMENSIONS

    1/2"(12.7mm)

    conduit hole

    3 1/2"(89mm)

    3/4" (19.05mm)

    6"(152mm)

    7 3/8"(187mm)H

    in(cm)

    W

    DESCRIPTIONThe 51XBR Series XTRA-BRITE LED beacons are combination visual and audible signaling devices, designed for indoor or outdoor applications . The integrated horn is synchronized with the flashing LED . The unit features a cast metal base that can be used as a junction box . The double fresnel lens is made of shatter-resistant polycarbonate, and is designed to magnify the superbright LED .FEATURES LED light source with integrated horn Shatter-resistant double fresnel polycarbonate lens Five lens color options Immune to shock and vibration Cast metal base Suitable for indoor and outdoor applications

    XTRA-BRITE LED BEACON WITH HORN51XBR SERIES

    Supply Voltage 51XBRFx120A 120 VAC, 50/60 Hz, 51XBRFx24D 24 VDCCurrent 51XBRFx120A 175 mA 51XBRFx24D 275 mAMax. Off State Leakeage Current 10 mASurge (inrush / duration) 51XBRFx120A 50 A / 260 s 51XBRFx24D 10 A / 120 sColors Amber, blue, green,red, white Flash Rate 65 FPMProjected LED Life 148,000 hoursHorn Loudness 85 dB @10'Strobe Tube Life 148,000 hoursOperating Temperature -31F to 150F (-35C to 66C)Dimensions 7 .38"H x 6"W (18 .7cm x 15 .2cm)Mounting Direct surface mount Mounted on 1/2 in. NPT conduit Mounted on a 4 in. octagon boxApprovals cULus Listed, uLWeight 2 .14lbs (0 .97 kg)Warranty 18 months

    SPECIFICATIONS

    ORDERING INFORMATION

    MODEL DESCRIPTION51XBRF Combination flashing LEDs with horns COLOR A Amber B Blue G Green R Red W White SUPPLY VOLTAGE 24D 24 VDC 120A 120 VAC @ 50/60 Hz

    57PLEDM G 24D Example: 51XBRFG24D Combination flashing LEDs with horns and 24V DC

    51XBR

    WIRING

    24 VDCWIRING

    RE

    D

    BLA

    CK

    + B

    LAC

    K

    WH

    ITE

    120 VACWIRING

    24 VDCPOWER

    120 VACPOWER

    +

    GR

    EE

    N

    GND NEUTRAL

    Wire nuts not included.

  • ALARMS & INDICATION

    70

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

    POLARIS CLASS LED BEACON57 SERIES

    DESCRIPTIONEdwards Polaris Class 57PLEDM LED beacons are NEMA Type 4X and IP66 rated visual signals designed for indoor and outdoor applications .The Polaris Class is designed for industrial or commercial applications that require the longevity of an LED combined with the brightness of a xenon strobe . These units are very effective in high noise areas where ear protection is worn or audible signals may not be heard .

    FEATURES Six lens colors Seven flash patterns (includes steady-on) Hidden in Plain Sight (HIPS) switch High level of immunity to shock and vibration Black or gray base option

    Supply Voltage 57PLEDMx24ADx 12 VDC, 0 .7A, 24 VAC/VDC, 0 .55A 57PLEDMx120Ax 120 VAC, 50/60Hz, 0 .25ALeakage Current Off State Leakage 5 mASurge Current 57PLEDMx24ADx 8 .5A/2ms 57PLEDMx120Ax 4 .5A/1msColor Amber, blue, green, magenta, red, clearProjected LED Life 148,000 hoursFlash Mode 7 selectable patterns with HIPS switchOperating Temperature -31 to 150 .8F (-35 to 66C)Dimensions 8" x 6 .5" (203 x 165 mm) Enclosure Rating NEMA 4XMounting: On 3/4" (19mm) NPT threaded conduitApprovals UL 1638 and cUL Listed (E11459)Weight 3 .4 lbs (1 .54 kg)Warranty 18 months

    SPECIFICATIONS DIMENSIONS

    8"(203mm)

    6.5"(165mm)

    WIRING

    ACCESSORIES

    BLA

    CK

    RE

    D

    24 VACWIRING

    24 VACPOWER

    +

    GR

    EE

    N

    GND NEUTRAL

    24 VDCWIRING

    RE

    D

    BLA

    CK

    +

    24 VDCPOWER

    BLA

    CK

    WH

    ITE

    120 VACWIRING

    120 VACPOWER

    +

    GR

    EE

    N

    GND NEUTRAL

    Wire nuts not included.

    57PLEDMR

    57PLEDMB

    57PLEDMA

    ORDERING INFORMATION

    MODEL DESCRIPTION57PLEDM LED beacon COLOR A Amber B Blue G Green M Magenta R Red W White SUPPLY VOLTAGE 24AD 12-24 VDC, 24 VAC @ 50/60 Hz 120A 120 VAC @ 50/60 Hz BASE COLOR (Blank) Gray B Black

    57PLEDM G 24AD Example: 57PLEDG24AD LED beaconwith green lens, gray base, and 12-24 VDC, 24 VAC @ 50/60 Hz

    CBRCorner Mount Bracket

    WBRWall Mount Bracket

    ACCESSORIES PAGECBR Corner Mount Bracket 70-71WBR Wall Mount Bracket 70-71

  • NEW!

    71

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

    POLARIS CLASS LED BEACON94 SERIES

    DESCRIPTIONEdwards Polaris Class 94PLEDM LED beacons are NEMA Type 4X and IP66 rated visual signals designed for indoor and outdoor applications . The units are available in Edwards 94 Series housing in 12-24 VDC, 24 VAC, 120 VAC and are field configurable with up to seven flashing patterns, including steady-on, utilizing a Hidden In Plain Sight (HIPS) switch . The inner, double fresnel lens is made of a high grade polycarbonate and is designed to magnify the ultra-bright LEDs inside . A clear, outer, impact-resistant polycarbonate dome offers additional protection against accidental impacts with machinery or falling objects . It also acts as a protective and simple to clean dust and residue cover . The Polaris Class beacons are designed to be mounted on 3/4 inch NPT conduit (indoor or outdoor) . For outdoor installation and to maintain the NEMA and IP ratings, the beacon must be mounted with the dome facing directly up . When installing the beacon indoors in dry environments, it can be mounted in any position . The 94 Series housing has a cast base that can function as a junction box . The Polaris Class is designed for any industrial or commercial applications that require the longevity of an LED and the brightness of a xenon strobe . These units are very effective in high noise areas where ear protection is worn or audible signals may not be heard .

    FEATURES 12-24 VDC, 24 VAC, 120 VAC Six lens colors Seven flash patterns (includes steady-on) Hidden in Plain Sight (HIPS) switch 3/4" (19mm) NPT threaded conduit High level of immunity to shock and vibration Black or gray base option

    Supply Voltage 94PLEDMx24ADx 12 VDC, 0 .7A; 24 VAC/DC, 0 .55A 94PLEDMx120Ax 120 VAC, 50/60Hz, 0 .25ALeakage Current Off State Leakage 5mASurge Current 94PLEDMx24ADx 8 .5 A / 2 ms 94PLEDMx120Ax 4 .5 A / 1 msColor Amber, blue, green, magenta, red,

    white/clearProjected LED Life 148,000 hoursFlash Mode 7 Selectable Patterns with HIPS

    SwitchOperating Temperature -31 to 150 .8F (-35 to 66C)Dimensions 94PLEDMx Models 8 .25" x 7 .75" (210 x 200 mm)Enclosure Rating NEMA 4X and IP66 RatedMounting On 3/4 inch NPT conduit

    (indoor or outdoor)Approvals UL 1638 and cUL Listed (E11459)Weight 6 .10 lbs (2 .77 kg)Warranty 18 months

    94PLEDMA 94PLEDMR 94PLEDMG

    BLA

    CK

    RE

    D

    24 VACWIRING

    24 VACPOWER

    +

    GR

    EE

    N

    GND NEUTRAL

    24 VDCWIRING

    RE

    D

    BLA

    CK

    +

    24 VDCPOWER

    BLA

    CK

    WH

    ITE

    120 VACWIRING

    120 VACPOWER

    +

    GR

    EE

    N

    GND NEUTRAL

    Wire nuts not included.

    DIMENSIONS

    WIRING

    7.75"(200mm)

    8.25"(210mm)

    HIPSProgramming Switch

    ORDERING INFORMATIONMODEL DESCRIPTION94PLEDM LED beacon COLOR A Amber B Blue G Green M Magenta R Red W White SUPPLY VOLTAGE 24AD 12-24 VDC, 24 VAC @ 50/60 Hz 120A 120 VAC @ 50/60 Hz BASE COLOR (Blank) Gray B Black

    94PLEDM G 24AD B Example: 94PLEDG24AD LED beaconwith green lens, black base, and 12-24 VDC, 24 VAC @ 50/60 Hz

    ACCESSORIES PAGECBR Corner Mount Bracket 70-71WBR Wall Mount Bracket 70-71

    SPECIFICATIONS

  • ALARMS & INDICATION

    72

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

    XTRA-BRITE LED HAZARDOUS LOCATION BEACON107XBR SERIES

    DESCRIPTIONThe 107XBR hazardous location XTRA-BRITE LED visual signals are NEMA Type 3R and Type 4 heavy-duty visual signals designed for indoor or outdoor applications . The units are available in 24 VDC or 120 VAC and are field configurable for steady-on or flashing (65 fpm) . The inner, double fresnel lens is made of a high grade polycarbonate and is designed to magnify the super-bright LEDs inside . A clear, outer, impact-resistant glass globe also covers the lens and an optional dome guard fits over the glass dome to protect it against accidental impacts with machinery or falling objects . The 107XBR has three different mounting configurations including the pendant mount, bracket mount and ceiling mount and can be mounted on 3/4" NPT threaded conduit . The 107XBR is designed for applications such as petroleum refineries, utility gas plants, dry cleaning plants, fuel servicing areas and other similar applications .

    FEATURES Available in 24VDC or 120VAC Five lens colors Steady-on or flashing in every unit 3/4" NPT threaded conduit High level of immunity to shock and vibration Three mounting options: pendant, bracket or ceiling UL Listed for Class I, Division 2, Groups A, B, C, D; Class II,

    Division 1, Groups E, F, G; Class II, Division 2, Groups F & G and Class III, Division 1 locations

    UL and cUL Listed for Marine environments (120VAC only)

    107XBRBMA

    Flash Rate65 fpm

    107XBRCMG

    107XBRPMR

    Supply Voltage 107XBRxMx24D 24 VDC 107XBRxMx120A 120 VAC, 60HzCurrent 107XBRxMx24D 220 mA 107XBRxMx120A 115 mAColor Amber,blue,green,red,clearFlash Mode Steady on or flashing

    (65 FPM, field configurable)Project LED Life 148,000 hoursOperating Temperature See Table on next page Dimensions 7" X 10 .13" (178 x 260 mm)Enclosure Rating NEMA 3R and NEMA 4Mounting Bracket mount, pendant mount, ceiling mount Approvals UL & cUL Listed, UL Listed for Marine Use Weight 107XBRBMx 10 .87 lb (4 .93 kg) 107XBRCMx 9 .87 lb (4 .47 kg) 107XBRPMx 8 .97 lb (4 .06 kg)Warranty 18 months

    SPECIFICATIONS

    * Class II and Class III only apply to the pendant mount versions with clear globes .** Marine Rating applies to UL listing only .

    Wire nuts (not supplied)Yellow,Not Connected(wire nut supplied)

    Connect leads toPower Source

    DC units; Red positive (+)AC units; Black HotDC units; Black negative (-)AC units; White neutral

    Wire nuts (not supplied)

    Connect leads toPower Source

    DC units; Red positive (+)AC units; Black HotDC units; Black negative (-)AC units; White neutral

    Yellow

    DC units: Connectto Positive (+)AC units: Connect to Hot

    (Yellow wire connectedfor Optional flash pattern)

    WIRING

  • NEW!

    73

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

    XTRA-BRITE LED HAZARDOUS LOCATION BEACON107XBR SERIES

    OPERATING TEMPERATURE CODES

    11 3/8"(289mm)

    10 1/2"(267mm)

    10 7/8"(276mm)10 1/4"(260mm)

    7"(172mm)

    9 7/8"(251mm)

    10 1/8"(260mm)

    7"(178mm)

    9 3/4"(248mm)

    4"(102mm)

    DIMENSIONS

    Pendant Mounting Bracket Mounting Ceiling Mounting

    ORDERING INFORMATION

    MODEL DESCRIPTION107XBR Hazardous Location LED Beacon MOUNTING PM Pendant BM Bracket CM Ceiling COLOR A Amber B Blue G Green R Red W White SUPPLY VOLTAGE 24D 24V DC 120A 120V AC @ 60 Hz

    107XBR BM W 120A Example: 107XBRBMW120A Hazardous LocationLED Beacon with bracket mounting, white LED, and 120V AC @ 60 Hz

    Ambient temperature

    Class I, Div. 2 Groups A, B, C, D

    Class II, Div. 2, Groups F, G; Class III, Div. 2 Class II, Div. 1, Groups E, F, G; Class III, Div. 1

    40C 135C (T4) 85C (T6) 55C 135C (T4) 85C (T6) 65C 135C (T4) 85C (T6)

    Note: Class II and Class III only apply to the pendant mount versions with clear globes.

    ACCESSORIESEDVPGU1 Optional Dome Gaurd

  • ALARMS & INDICATION

    74

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

    ORDERING INFORMATION

    WIRING

    105-L SeriesLens

    105XBR Base

    Wire nuts(not supplied)

    DC units; Red Positive (+), AC units; Black Hot

    18 Wire Leads

    DC units; Black Negative (-), AC units; White Neutral

    Power Source Wires

    OFF

    OFF

    ON

    ON

    1

    2

    OFF

    OFF

    ON

    ON

    1

    2

    STEADY

    65 FPM

    XTRA-BRITE LED ADVERSE LOCATION VISUAL SIGNALS105XBRM SERIES

    DESCRIPTIONThe 105XBRM Series LED visual signals are heavy duty, reliable, UL, cUL beacons . The 105XBRM Series features a UL listed Type 4X enclosure and is UL Listed for Marine Use . The 105XBRM Series has three different configurations for mounting that include the 105BX junction box, the 105BM mounting bracket, and the 105PM pipe mount attachment . The unit can be mounted on 3/4 NPT using the 105PM pipe attachment . It can also be surface mounted using the 105BX junction box, or wall mounted using the 105BX junction box with the 105BM mounting bracket . They can only be used with metallic wiring systems when installed at the end of the run .FEATURES Available in 24V DC or 120V AC Three mounting bases: 3/4" pipe mount attachment,

    outlet box attachment, or wall mounting bracket 65 fpm mode field-selectable via dipswitch Immune to shock and vibration

    105XBRMB

    (Dipswitches located inside the unit)

    MODEL105XBRM

    105XBRM Example: 105SLEDBN5 Steady-OnLED with blue lens and light sourceand 120V 60 Hz supply voltage

    B N5

    DESCRIPTIONXTRA-BRITE LED Adverse Locations Visual SignalsCOLORABGRW

    AmberBlueGreenRedWhiteSUPPLY VOLTAGE24D120A

    24V DC120V AC

    5"(127 mm)

    4.5"(114 mm)

    4.5"(114 mm)

    5.25"(133 mm)

    6"(152 mm)

    2"(51 mm)

    4.5"(114 mm)

    2.25"(57 mm)

    105PM Pipe Mount Attachment 105BM Mounting Bracket(use with 105BX)

    105BX Outlet Box Attachment

    MODEL Class Division Group Operating Temperature105XBRMx24D I 2 A, B, C, D T4A (120C, 248F)105XBRMx120A I I 2 F, G T4A (120C, 248F)

    I I I T4A (120C, 248F)

    HAZARDOUS LOCATION RATINGS

    Supply Voltage 105XBRMx24D 24 VDC 105XBRMx120A 120 VAC 50/60HzCurrent Rating 105XBRMx24D 0 .215 105XBRMx120A 0 .108AColor Amber, blue, green, red, whiteFlash Mode Steady on or 65 FPM (dipswitch

    settings)Projected LED Life 148,000 hoursOperating Temperature -31 to 212F (-35 to 100C)Dimensions 4 .75" X 3 .75" (121 x 95mm)Enclosure Rating NEMA 4XMounting " pipe mount attachment, outlet

    box attachment, or wall mounting bracket

    Approvals UL & cUL Listed, UL Listed for Marine Use

    Weight: 1 .4 lbs (0 .63 kg)Warranty: 18 months

    ACCESSORIES PAGE105BM Wall-mount bracket (requires 105BX) 74,77,479-480105BX Surface-mount box 74,77,479-480105PM Pipe-mount base 74,77,479-480

    SPECIFICATIONS

  • NEW!

    75

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

    XTRA-BRITE LED BEACONS125XBR SERIES

    DESCRIPTIONThe Edwards 125XBR Class XBR XTRA-BRITE LED beacons are UL and cUL listed dual mode signaling devices, available in two versions, Steady-On/Flashing (125XBRM) and Steady-On/Lightburst (125XBRZ) . Both versions feature a corrosion resistant Type 4X enclosure and can be panel or conduit mounted . The lens is made of shatter resistant polycarbonate . Both the 125XBRM and 125XBRZ beacons are dual mode devices, maximizing application flexibility while reducing inventory costs . It can also be panel-mounted using the mounting gasket provided with the unit .

    FEATURES Available in 24 VDC or 120 VAC Available with amber, blue, green, red or white lens Available with gray or black base Option for panel or conduit mounting Available in dual mode Steady-On/Flashing LED or

    Steady-On/Lightburst LED versions

    Gasket (provided for use when direct panel mounting)

    Locknut - 1.3625" O.D. (provided for use when direct panel mounting)

    3.25"(82.6mm)

    3.875"(98.4mm)

    Double threaded forpanel mounting or1/2" internal or 3/4" externalconduit mounting

    DIMENSIONS

    Supply Voltage 125XBRxx24Dx 24 VDC 125BRxx120Ax 120 VAC,50/60HzCurrent 125XBRxx24Dx 0 .215A 125BRx120Ax 0 .108AColor Amber, blue, clear, green, redFlash Rate 125XBRM STEADY-ON/FLASHING (65 FPM) 125XBRZ STEADY-ON/LIGHTBURST (420FPM)Projected LED Life 148,000 hoursOperating Temperature -31 to 150F (-35 to 66C)Dimensions 3 .875"H3 .875"H(98 .4mm) X 3 .25"W

    (82 .6mm)(98 .4mm) X 3 .25"W (82 .6mm)Enclosure Rating NEMA 4xMounting On 1/2" or 3/4" NPT conduit using a 1/2"

    internal or 3/4" external conduit hubApprovals cULus ListedWeight 0 .5lbsWarranty 18 months

    SPECIFICATIONS

    ORDERING INFORMATION

    125XBRZR120A Dual Mode XBR LED Beacons in NEMA 4X Enclosure, with Steady-On Lightburst, red LED, 120V AC @ 60 Hz, and gray base

    MODEL DESCRIPTION125XBR Dual Mode XBR LED Beacons in NEMA 4X Enclosure OPERATION M Steady-On/ Flashing LED Z Steady-On/ Lightburst COLOR A Amber B Blue G Green R Red W White SUPPLY VOLTAGE 24D 24V DC 120A 120V AC @ 60 Hz BASE COLOR (BLANK) Gray B Black

    125XBR Z R 120A Example:

    125XBR

    WIRING

    125XBR SeriesLED Visual IndicatorGasket(supplied)Locking Nut -

    1.3625" OD(supplied)

    Control panel(Enclosure)

    Wire Nuts(Not Supplied)

    18 Wire Leads

    Power SourceWires

    DC units; Red Positive (+)AC units; Black HotDC units; Black negative (-)AC units; White neutral

    Yellow, Not connected (wire nut supplied) ACCESSORIES

    125GRD Optional Gaurd for use with 125 Class BeaconsCBR Corner Mount BracketWBR Wall Mount Bracket

  • ALARMS & INDICATION

    76

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

    Supply Voltage 105XBRiRxA24D 24 VDC 105XBRiRxA120A 120 VAC, 50/60HzCurrent 105XBRiRxA24D 0 .15A 105XBRiRxA120A 0 .1AMax. Off State Leakage Current 5mASurge (inrush/duration) 105XBRiRxA24D 28A/65uSeconds 105XBRiRxA120A 28 .5A/212uSecondsLED Colors Red/Green/Amber or Red/Blue/AmberFlash Mode Dipswitch settings for use with or without

    external controlFlash Rate XTRA-SAFE Mode; Red 240 FPM,

    Amber120 FPM, Green or Blue 65 FPMProjected LED Life 148,000 hoursOperating Temperature 31 to 150F (-35 to 66C)Dimensions 4 .5"W x 4 .625"H (114 x 117 mm)Enclosure Rating NEMA 4XMounting " pipe mount attachment, outlet box

    attachment, or wall mounting bracketApprovals UL & cUL ListedWeight 1 .4 lb(0 .63 kg)Warranty 18 months

    105XBRi-RGA

    DESCRIPTIONThe Edwards 105XBRi Series XTRA-BRITE LED Multi-Status Indicator is a heavy duty, reliable UL and cUL listed, multi-color visual signaling device . It features a corrosion resistant Type 4X enclosure that is UL listed for Marine use, and can be panel or conduit mounted . The base is manufactured from glass-reinforced thermoplastic polyester resin and the double fresnel lens is made of shatter resistant polycarbonate . The lights are available in 24 VDC and 120 VAC 50/60 Hz, in either Red/Blue/Amber or Red/Green/Amber .

    FEATURES Available in 24V DC or 120V AC Available in Red/Blue/Amber or Red/Green/Amber Three mounting bases: 3/4" pipe mount attachment, outlet

    box attachment, or wall mounting bracket PLC compatible XTRA-SAFE Technology enables status indication for

    those who are color blind Dip switch settings for use with or without external control Immune to shock and vibration

    XTRA-BRITE LED MULTI-STATUS INDICATOR105XBRI SERIES

    SPECIFICATIONS

    4.625"(92mm)

    4.375"(111mm)

    4.5"(114mm)

    4.625"(117mm)

    Cat. No Class Division Group Operating Temperature 105XBRIRGA24D l 2 A,B,C,D T5 (100C, 212F)105XBRIRGA120A ll 2 F,G T5 (100C, 212F)

    lll T5 (100C, 212F)105XBRIRBA24D l 2 A,B,C,D T6 (85C, 185F)105XBRIRBA120A ll 2 F,G T6 (85C, 185F)

    lll T6 (85C, 185F)

    HAZARDOUS LOCATION RATINGS

    DIMENSIONS

  • NEW!

    77

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

    XTRA-BRITE LED MULTI-STATUS INDICATOR105XBRI SERIES

    ORDERING INFORMATION

    MODEL DESCRIPTION105XBRi LED Multi-Status Indicator in NEMA 4X Enclosure COLORS RGA Red, Green, Amber RBA Red, Blue, Amber SUPPLY VOLTAGE 24D 24 VDC 120A 120 VAC @ 50/60 Hz

    105XBRi RGA 24D Example: 105XBRiRGA24D LED Multi-Status Indicator in NEMA 4X Enclosure with Red, Green, and Amber lens, and 24 VDC

    5"(127mm)

    4.5"(114mm) 2"(51mm) 2.25"(57mm)

    5.25"(133mm)

    0.34"(9mm) Diameter

    (4) 3/4"Knockouts

    6"(152mm)

    4.5"(114mm)

    4.5"(114mm)

    105BM Mounting Bracket(use with 105BX)

    105BXOutlet Box Attachment

    105PMPipe Mount Attachment

    WIRING

    105-LC Lens

    (2) Screws to mount105BX to themounting surface

    MountingSurface

    Power source wires

    Wire Nuts(not supplied)

    Amber (DC + or AC hot for Amber LEDactivation)

    Red (DC + or AC hot forRed LED activation)

    Black (DC -) or White (AC neutral)

    Blue with Green tracer(DC + or AC hot for Blue or Green

    LED activation (depending on model))

    Applications WITHa PLC or Controller*

    Applications WITHOUTa PLC or Controller* - XTRA-SAFE TechnologyDisabled

    Applications WITHOUTa PLC or Controller* - XTRA-SAFE TechnologyEnabled(Factory Default)

    *It is generally recommended that both dipswitches, SW1 and SW2, be set to OFF for applications using an external Programmable Logic Controller (PLC) or other external controller. A PLC or controller, how-ever, can be used with any of the shown configurations.

    Dipswtich Settings:

    (Dipswitch located inside the unit)

    ACCESSORIES PAGE105BM Wall-mount bracket (requires 105BX) 74,77,479-480105BX Surface-mount box 74,77,479-480105PM Pipe-mount base 74,77,479-480

  • ALARMS & INDICATION

    78

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

    125XBRi

    DESCRIPTIONThe Edwards 125XBRi Series XTRA-BRITE LED Multi-Status Indicator is a UL and cUL listed, multi-color visual signaling device . It features a corrosion resistant Type 4X enclosure and can be panel or conduit mounted . The base is manufactured from a 33% glass filled nylon, providing high resistance to heat and high chemical resistivity . The lens is made of shatter resistant polycarbonate . The lights are available in 24 VDC and 120 VAC 50/60 Hz, in either Red/Blue/Amber or Red/Green/Amber .FEATURES Available in 24 VDC or 120 VAC Available with gray or black base Available in Red/Blue/Amber or Red/Green/Amber Option for panel or conduit mounting PLC Compatible XTRA-SAFE Technology enables status indication for

    those who are color-blind Dip switch settings for use with or without external control Immune to shock and vibration Protective wire guard available, Cat. No. 125GRD

    Gasket (provided for use when direct panel mounting)

    Locknut - 1.3625" O.D. (provided for use when direct panel mounting)

    3.25"(82.6mm)

    3.875"(98.4mm)

    Double threaded forpanel mounting or1/2" internal or 3/4" externalconduit mounting

    DIMENSIONS

    XTRA-BRITE LED MULTI-STATUS INDICATOR125XBRI SERIES

    Supply Voltage 125XBRiRxA24Dx 24 VDC 125XBRiRxA120Ax 120 VAC, 50/60HzCurrent 125XBRiRxA24Dx 0 .15A 125XBRiRxA120Ax 0 .1AMax. Off State Leakage Current

    5 mASurge (inrush/duration) 125XBRiRxA24Dx 28 .5A/65uSeconds 125XBRiRxA120Ax 28 .5A/212uSecondsLED Colors Red/Green/Amber or Red/Blue/

    AmberFlash Mode Dipswitch enabledFlash Rate XTRA-SAFE Mode, Red 240

    FPM, Amber120 FPM, Green or Blue 65 FPM

    Projected LED Life 148,000 hoursOperating Temperature -31 to 150F (-35 to 66C)Dimensions 3 .25"W x 3 .875"H (82 .6 x 98 .4mm)Enclosure Rating NEMA 4XMounting Conduit or panel mountApprovals UL & cUL ListedWeight 0 .5 lbs (0 .22 kg)Warranty 18 months

    SPECIFICATIONS

  • NEW!

    79

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

    WIRING

    Applications WITHa PLC or Controller*

    Applications WITHOUTa PLC or Controller* - XTRA-SAFE TechnologyDisabled

    Applications WITHOUTa PLC or Controller* - XTRA-SAFE TechnologyEnabled(Factory Default)

    *It is generally recommended that both dipswitches, SW1 and SW2, be set to OFF for applications using an external Programmable Logic Controller (PLC) or other external controller. A PLC or controller, how-ever, can be used with any of the shown configurations.

    Dipswtich Settings:

    (Dipswitch located inside the unit)

    XTRA-BRITE LED MULTI-STATUS INDICATOR125XBRI SERIES

    125XBRI Series ChameleonLED Visual Indicator

    Gasket(supplied)

    Wire nuts(not supplied)

    Locking Nut -1.3625" OD

    (supplied)Control panel

    (Amber LED activation)DC Units; Amber Positive (+)AC Units; Amber Hot

    (Red LED activation)(DC Units; Red positive (+)AC Units Red HotDC Units; Black DC common (-)

    AC Units; White AC neutral

    (Blue or Green LED activation)DC Units; Blue with green stripe, Positive (+)AC Units; Blue with green stripe, Hot

    Wire color corresponds with each indicated color .Red wire = Red LED's

    Yellow wire = Amber LED'sBlue with Green tracer wire = Green or Blue LED's

    ORDERING INFORMATION

    125XBRi-RGA-120A LED Multi-Status Indicator in NEMA 4X Enclosure, with red, green, and amber LEDs, with 120 VAC @ 60 Hz, and gray base

    MODEL DESCRIPTION125XBRi LED Multi-Status Indicator in NEMA 4X Enclosure COLOR RGA Red, Green, Amber RBA Red, Blue, Amber SUPPLY VOLTAGE 24D 24 VDC 120A 120 VAC @ 60 Hz BASE COLOR (BLANK) Gray B Black

    125XBRi RGA 120A Example:

    ACCESSORIES PAGE125GRD Optional Guard for Use with 125 Class Beacons CBR Corner Mount Bracket 70-71WBR Wall Mount Bracket 70-71

  • ALARMS & INDICATION

    80

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

    Supply Voltage Light Modules 24 VDC, 0 .065A; 24 VAC, 0 .075A to 0 .085A 120 VAC/DC, 0 .035A Piezoelectric Sound Modules 12 VAC/DC, 0 .003A; 24 VAC/DC, 0 .006mA;

    48 VAC/DC, 0 .013A; 120 VAC, 0 .004A; 240 VAC, 0 .01A Magnetodynamic Sound Modules 12 VAC, 0 .12-0 .95A; 12 VDC, 0 .03-0 .335A;

    24 VAC 0 .17-1 .06A; 24VDC, 0 .045-0 .45A; 120VAC, 0 .04-0 .105A; 240 VAC, 0 .025-0 .06A Color White, red,green,blue, amberFlash Mode Steady on, Single (75FPM), Double

    (85FPM), Triple (85FPM)Horn Loudness Piezoelectric Sound Modules 12 VAC/DC, 72-79dB; 24 VAC/DC, 77-85dB 48 VAC/DC, 79-89dB; 120 VAC, 75-81dB 240 VAC, 78-87dB Magnetodynamic Sound Modules 12 VAC/DC, 86 .5-103 .5dB; 24 VAC/DC,

    91-107dB; 120 VAC, 93-103dB; 240 VAC, 93-103 .5dB

    Operating Temperature Light Modules -22 to 122F (-30 to 50C) Piezoelectric Sound Modules -22 to 140F (-30 to 60C) at 12V to 48V; -22 to 132 .8F (-30 to 56C) at 120V to

    240V Magnetodynamic Sound Modules -22 to 140F (-30 to 60C) at 12V to 24V;

    -22to 122F (-30 to 50C) at 120V to 240VDimensions Base 1 .89"H x 2 .678" dia (48 x 68 mm) Light Module 2 .323"H x 2 .953"dia (59 x 75 mm) Sound Module 4 .095"H x 2 .953"dia (104 x 75 mm)Enclosure Rating NEMA 3R, 4X,IP66 rated base and light

    modules, IP54 rated sound modulesMounting Wall mount or Surface mountWeight Base 0 .83 lb (0 .38 Kg) Light Modules 0 .81 lb (0 .37 Kg) Piezoelectric Sound Modules 1 .04 lb (0 .47 Kg) Magnetodynamic Sound Modules 1 .28 lb (0 .58 Kg)Approvals cULus Listed, CE approvedWarranty 18 months

    LED STACKLIGHT200 CLASS CLEARVIEW

    DESCRIPTIONThe 200 Class 70mm ClearView LED Stacklight is a versatile, multi-mode signaling device that may contain up to five light modules, or four light modules and one sounder module in a single, integrated stack . The lens modules are clear, and are available with red, amber, blue, green, yellow and white LEDs in 24 VAC, 24 VDC and 120 VAC . The lenses are made from a self-extinguishing polycarbonate material and are scratch and impact resistant . Optional piezoelectric and magnetodynamic sounder modules complement the visual signals of the Stacklight, offering several audible tones depending on the model chosen . The sound module has been designed so that it is always in the top position of the Stacklight . The 200 Class 70mm ClearView LED Stacklight features an interlocking system for quick assembly without any tools . It is available in gray or black and offers multiple voltage ranges to provide solutions for industrial applications, while also meeting machine builder and OEM requirements .

    FEATURES 24 VAC, 24 VDC and 120 VAC Stackable up to five modules including sounder Quick and simple assembly with NO tools required Multi-Mode (Steady, Single, Double or Triple Flash) Two optional sounders available; Piezoelectric: Six user

    selectable tones, Magnetodynamic: 32 user selectable tones Clear lens LED light source Available in Gray or Black IP65 or IP54 available cULus Listed CE approved

    270CLED

    SPECIFICATIONS

    WIRING

    V DC () (+)V AC

    5

    4

    3

    2

    1

    C

    On the power supply line, use appropriate time-lag fuses according to the voltage.

    March 2014

  • NEW!

    81

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

    LED STACKLIGHT200 CLASS CLEARVIEW

    MODEL DESCRIPTION270CLED LED Stacklight Module MODULE TYPE S Steady M Multimode COLOR A Amber B Blue G Green R Red Y Yellow W White SUPPLY VOLTAGE 24AD 24V AC/DC 120A 120V AC

    270CLED M W 120A Example:

    BASE COLOR(BLANK) GrayB Black

    270CLEDMW120A LED Stacklight Module with multimode module, white LED, 120 VAC, and gray base

    SOUND MODULES

    DIMENSIONS/ORDERING INFORMATION

    LED LIGHT MODULES

    LIGHT MODULE

    2.953"(75mm)

    2.323"(59mm)

    3.11"(79mm)

    2.835"(72mm)

    2.717"(69mm)

    BASE AND COVER

    .788"(20mm)

    2.323"(59mm)

    2.678"(68mm)

    1/2" NPT

    2.953"(75mm)

    1.89"(48mm)

    ACOUSTIC MODULE

    4.095"(104mm)

    2.953"(75mm)

    4.567"(116mm)

    70MM PIEZOELECTRIC (PZO) ACOUSTIC MODULE DIP SWITCH SETTINGS12 VDC/VAC 24 VDC/VAC 48 VDC/VAC 120 VAC 240 VAC

    Sound Type Diagram F (Hz)1 AdB

    at 1m AdB

    at 1m AdB

    at 1m AdB

    at 1m AdB

    at 1m

    Continuous reduced output 50/60 0.003 75 0.006 81 0.013 83 0.004 75 0.010 81

    Continuous maximum output 50/60 0.003 79 0.006 85 0.013 89 0.004 81 0.010 87

    Slow intermittent reduced output 50/60 0.003 72 0.006 77 0.013 79 0.004 76 0.010 78

    Slow intermittent maximum output 50/60 0.003 77 0.006 84 0.013 86 0.004 81 0.010 85

    Fast intermittent reduced output 50/60 0.003 74 0.006 79 0.013 81 0.004 76 0.010 79

    Fast intermittent maximum output 50/60 0.003 78 0.006 85 0.013 87 0.004 81 0.010 85

    1For AC voltages only

    on

    21 3on

    21 3on

    21 3on

    21 3on

    21 3on

    21 3

    March 2014

    Piezoelectric Sounder270PZO1248AD 12-48 AC/DC, Gray270PZO1248ADB 12-48 AC/DC, Black270PZO120240A 120-240 VAC, Gray 270PZO120240AB 120-240 VAC, BlackMagnetodynamic Sounder270MDA1224AD 12-24 VAC/DV, Gray 270MDA1224ADB 12-24 VAC/DV, Black270MDA120A 120 VAC, Gray270MDA120AB 120 VAC, Black270MDA240A 240 VAC, Gray270MDA240AB 240 VAC, Black **NOTE: Add B to the end of the model number for black unit.

    ACCESSORIES270FLXT 270 Flexible Steel Extension Stem - 370mm270FMLADAPT 270 Female Adapter Base - Gray270JBX** Junction Box - Gray270KIT** Footing with Extension - Gray270SSXT100 270 Stainless Steel Extension Stem - 100mm270SSXT200 270 Stainless Steel Extension Stem - 200mm270SSXT400 270 Stainless Steel Extension Stem - 400mm270TEP** Threaded Extension Pole 100mm - Gray270THF** Threaded Footing - Gray270TWM** Threaded Wall Mount - Gray270TWM2** Double Threaded Wall Mount - Gray

  • ALARMS & INDICATION

    82

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

    Supply Voltage 12-24 VAC/VDC, 24-240 VACVoltage Range 24 VAC/ VDC, 110 VAC, 24 VAC , 24

    VDCPower Light module 5W 12-120 VAC/VDC (7W 240 VAC) Horn module 12V-2 .7 mA, 24V-6 mA, 110V-4

    mA,240V-8 .5 mAColor Blue, amber,red,green, yellow, clearFlash Rate Incandescent LED 110 FPM 20 FPM Strobe 65 FPM 10 FPM(24 VAC/DC) 90 FPM 20 FPM (110/240 VAC)Horn Loudness Medium, 76-86 dBOperating Temperature -22 to 140F (-30 to 60C)

    Strobe 14 to 122F (-10 to 50C)Dimensions Base 2 .68"H x 2 .95" dia (6 .8 x 7 .5 cm) Light 2 .72"H x 2 .95" dia (6 .9 x 7 .5 cm) Horn 3 .11"H x 2 .95" dia (7 .9 x 7 .5 cm)Mounting Wall, two holes; surface, four holes;

    2 .13" (5 .4 cm) centersEnclosure IP66 Horn IP20 upward mount Ip 24 downward mountApprovals CE UL Listed File E194312Warranty 18 months

    DESCRIPTIONThe TWS Series Tower Lights enable stacking of up to five signaling devices . Each device has its own set of contacts . Starting with a bottom module, up to five devices can be added in any combination of continuous and flashing incandescent lights, continuous and flashing LED lights, and Xenon strobes . Each stack can be capped with a horn . Each light comes in a variety of colors, and all lamps are replaceable . Several wall- and pedestal-mounting configurations are available .

    OPERATION Horns IP20 upward mount IP24 downward moun Ratings IP66

    SPECIFICATIONS

    WIRING

    75 MM TOWER LIGHTSTWS SERIES

    0 .5-1 .5 mm2(22-16 AWG)

    54 3 2 1

    COMMON

    0 .4 Nm Max .(3 .5 lb-in)

    012

    345

    4

    1

    2

    3

    5

    C

    VDC(VAC)

    +

    Stack withTWS-BS Stack with

    TWS-BP1

    Two stacks withTWS-BP2

    Stack withTWS-KIT

    March 2014

  • NEW!

    83

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

    75 MM TOWER LIGHTSTWS SERIES

    ORDERING INFORMATION

    Steps Direction Part Number Description

    1Select Module and Cap

    (1 required)TWS-BC Bottom module and cap

    2Select

    Mounting Base

    (1 required)

    TWS-BS Base with gasketTWS-BP1 Single wall-mount baseTWS-BP2 Double wall-mount baseTWS-KIT Base and stem extension

    3Select

    Lighting Modules

    (5 maximum)

    Module Voltage Range

    Color Continuous Incandescent

    Flashing Incandescent

    Continuous LED

    Flashing LED

    Strobe

    Part Number24 VAC BLUE TWS-F1G TWS-L1G TWS-FL1G TWS-LL1G TWS-X1G24 VDC BLUE TWS-F1N TWS-L1N TWS-FL1N TWS-LL1N TWS-X1N110 VAC BLUE TWS-F1A TWS-L1A TWS-FL1A TWS-LL1A TWS-X1A24 VAC AMBER TWS-F2G TWS-L2G TWS-FL2G TWS-LL2G TWS-X2G24 VDC AMBER TWS-F2N TWS-L2N TWS-FL2N TWS-LL2N TWS-X2N110 VAC AMBER TWS-F2A TWS-L2A TWS-FL2A TWS-LL2A TWS-X2A24 VAC RED TWS-F3G TWS-L3G TWS-FL3G TWS-LL3G TWS-X3G24 VDC RED TWS-F3N TWS-L3N TWS-FL3N TWS-LL3N TWS-X3N110 VAC RED TWS-F3A TWS-L3A TWS-FL3A TWS-LL3A TWS-X3A24 VAC GREEN TWS-F4G TWS-L4G TWS-FL4G TWS-LL4G TWS-X4G24 VDC GREEN TWS-F4N TWS-L4N TWS-FL4N TWS-LL4N TWS-X4N110 VAC GREEN TWS-F4A TWS-L4A TWS-FL4A TWS-LL4A TWS-X4A24 VAC YELLOW TWS-F5G TWS-L5G TWS-FL5G TWS-LL5G TWS-X5G24 VDC YELLOW TWS-F5N TWS-L5N TWS-FL5N TWS-LL5N TWS-X5N110 VAC YELLOW TWS-F5A TWS-L5A TWS-FL5A TWS-LL5A TWS-X5A24 VAC CLEAR TWS-F6G TWS-L6G TWS-X6G24 VDC CLEAR TWS-F6N TWS-L6N TWS-X6N110 VAC CLEAR TWS-F6A TWS-L6A - - TWS-X6A

    4 Select Horn (1 maximum)

    24 VAC TWS-AG24 VDC TWS-AN110 VAC TWS-AA

    -

    - -

    -

    March 2014

    ACCESSORIES691-K0A Control transformer, 120:24 VAC, 40 VA, Class 2DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUTDCPA-1.2 Power supply, 120 VAC In to 24 VAC/24 VDC OutTWS-BA15D-A 110VAC Replacement IC LampTWS-BA15D-G 24 VAC Replacement IC LampTWS-BA15D-N 24 VDC Replacement IC LampTWS-LED1-A 110 VAC Blue replacement LEDTWS-LED1-G 24 VAC Blue replacement LEDTWS-LED1-N 24 VDC Blue replacement LEDTWS-LED2-A 110 VAC Amber replacement LEDTWS-LED2-G 24 VAC Amber replacement LEDTWS-LED2-N 24 VDC Amber replacement LEDTWS-LED3-A 110 VAC Red replacement LEDTWS-LED3-G 24 VAC Red replacement LEDTWS-LED3-N 24 VDC Red replacement LEDTWS-LED4-A 110 VAC Green replacement LEDTWS-LED4-G 24 VAC Green replacement LEDTWS-LED4-N 24 VDC Green replacement LEDTWS-LED5-A 110 VAC Yellow replacement LEDTWS-LED5-G 24 VAC Yellow replacement LEDTWS-LED5-N 24 VDC Yellow replacement LEDTWS-LRX2J Universal Xenon replacement- requires solder connection

  • ALARMS & INDICATION

    84

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

    Supply Voltage 24 VAC, 120 VACContact Rating A600 10A, 600 VAC Q600 2 .5A, 600 VDCContact Configuration 4 Maintained or 6 Momentary

    maximumMechanical Life Contact 10 million operationsContact Type Self-cleaning silver contactsContact Resistance

  • NEW!

    85

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

    NEW!OPERATOR STATIONS

    ESB SERIES

    ORDERING INFORMATION

    Model DescriptionESB Break-Lens Operator Station (UL NKCR)

    Enclosure M1S NEMA 1 Metal enclosure, surface mountM3S NEMA 3R Metal enclosure, surface mountM2S NEMA 12,13 Metal enclosure, surface mountM4S NEMA 4,12 Metal Enclosure, surface mountM1F NEMA 1 Metal enclosure, flush mount

    Button StyleBLR Break Lens to Release Button model with red momentary push buttonBLP Break Lens - Push Button model maintained operator

    LegendBS Boiler Shut-downCS Chiller StopFN Exhaust FanHS HVAC Shut-downPO Power OffRP Refrigerant PurgeSD Shut DownSO Shut OffST StopVP Ventilation StopVT Ventilation StartXX* Custom Legend

    ESB M1S BLP CS Example: ESB-M1S-BLP-CS Break-Lens Operator Station, NEMA 1 metal enclosure, surface mount, maintained Break Lens Push Button operator, labeled as Chiller Stop

    -- -

    *18 character max, no color changes, no font changes, no company logos.

    ACCESSORIES PAGEES-LENS Replacment Lens for ESB series Operator Stations ES-NC Normally Closed Contact Block for Non-illuminated ESM, ESB, and ESP

    Emergency Operator Stations 98ES-NO Normally Open Contact Block for Non-illuminated ESM, ESB, and ESP Operator Stations 98

    March 2014

  • ALARMS & INDICATION

    86

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

    Supply Voltage 24 VAC, 120 VACContact Rating A600 10A, 600 VAC Q600 2 .5A, 600 VDCContact Configuration 4 Maintained or 6 Momentary

    maximumMechanical Life Contact 10 million operationsContact Type Self-cleaning silver contactsContact Resistance

  • NEW!

    87

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

    EMERGENCY OPERATOR STATIONSESM SERIES

    ORDERING INFORMATION

    Model DescriptionESM Maintained Emergency Operator Station (UL NISD)

    Enclosure

    M1S NEMA 1 Metal enclosure, surface mount

    NXS NEMA 4X,12 Non-metal enclosure, surface mount

    M2S NEMA 12,13 Metal enclosure, surface mount

    SXS NEMA 4X Stainless steel enclosure, surface mount

    M3S NEMA 3R Metal enclosure, surface mount

    M1F NEMA 1 Metal enclosure, flush mount

    Button Style

    PP0 Red maintained 40mm mushroom (push-pull)PT0 Red maintained 40mm mushroom (push-twist)PTL24* Illuminated 24V red maintained 40mm mushroom (push-twist, lamp included)PK0 Red maintained 40mm mushroom (push- key release)

    Legend

    BS Emergency - Boiler Shut-down

    CS Emergency - Chiller Stop

    FN Emergency - Exhaust Fan

    HS Emergency- HVAC Shut-down

    PO Emergency - Power Off

    RP Emergency - Refrigerant Purge

    SD Emergency - Shut Down

    SO Emergency - Shut Off

    ST Emergency - Stop

    VP Emergency - Ventilation Stop

    VT Emergency - Ventilation Start

    XX** Custom Legend

    ESM M1S PP0 CS Example: ESM-M1S-PP0-CS Maintained Emergency Operator Station, NEMA1 metal enclosure, surface mount, Red maintained 40mm push-pull mushroom, labeled as Chiller Stop

    - - -

    *Can only be used with M1S or M1F enclosure**18 character max, no color changes, no font changes, no company logos.

    March 2014

    ACCESSORIES PAGEES-KEY Replacement Key for PK0 option, ESM and ESP series 87,89ES-NC Normally Closed Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations 85,87,89ES-NO Normally Open Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations 85,87,89

  • ALARMS & INDICATION

    88

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

    Supply Voltage 24 VAC, 120 VACContact Rating A600 10A, 600 VAC Q600 2 .5A, 600 VDCContact Configuration 4 Maintained or 6 Momentary

    maximumMechanical Life Contact 10 million operationsContact Type Self-cleaning silver contactsContact Resistance

  • NEW!

    89

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

    ORDERING INFORMATION

    EMERGENCY OPERATOR STATIONSESP SERIES

    Model DescriptionESP Plate-mounted Emergency Operator Station (UL NISD)

    Button Style

    PP0 Red maintained 40mm mushroom (push-pull)PT0 Red maintained 40mm mushroom (push-twist)PTL24 Illuminated 24V Red maintained 40mm mushroom (push-twist, lamp included)PK0 Red maintained 40mm mushroom (push- key release)

    Legend

    BS Emergency - Boiler Shut-down

    CS Emergency - Chiller Stop

    FN Emergency - Exhaust Fan

    HS Emergency- HVAC Shut-down

    PO Emergency - Power Off

    RP Emergency - Refrigerant Purge

    SD Emergency - Shut Down

    SO Emergency - Shut Off

    ST Emergency - Stop

    VP Emergency - Ventilation Stop

    VT Emergency - Ventilation Start

    XX* Custom Legend

    ESP PP0 CS Example: ESP-PP0-CS Plate mounted Emergency Operator Station. Red Maintained Push-Pull button labeled as Chiller Stop.

    - -

    *18 character max, no color changes, no font changes, no company logos.

    ACCESSORIES PAGEES-KEY Replacement Key for PK0 option, ESM and ESP series 98ES-NC Normally Closed Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations 98ES-NO Normally Open Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations 98

    March 2014

  • ALARMS & INDICATION

    90

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

    OPERATOR STATIONSST120 SERIES

    ORDERING INFORMATION

    ACCESSORIES PAGEPILCLHCOV1 Clear hinged cover for push-pull model and ST120SN4XNM 90,92PILCLHCOV5 Clear hinged cover for break-lens model except ST120SN4XNM PILENS Replacement lens for break-lens model PILNCCB N.C. stackable contact block for MST1 stations 90-92PILNOCB N.O. stackable contact block for MST1 Stations 90-92

    - Red maintained 40 mm mushroom (push-pull) labeled Pull to Reset NEMA 4X and 12 nonmetallic surface-mount boxF Red maintained 40 mm mushroom (push-pull) labeled Pull to Reset NEMA 4 and 12 all-metal flush-mount boxFN1 Red maintained 40 mm mushroom (push-pull) labeled Pull to Reset NEMA 1 all-metal flush-mount boxN1 Red maintained 40 mm mushroom (push-pull) labeled Pull to Reset NEMA 1 all-metal surface-mount boxRP1 Red Raised Lid - Push Button padlockable solid lid over momentary flush round push buttonRP2 Red Raised Lid - Push Button padlockable solid lid over maintained flush round push button

    LEGENDSBS EMERGENCY - BOILER SHUT-DOWNCS EMERGENCY - CHILLER STOPFAN EMERGENCY - EXHAUST FANHS EMERGENCY - HVAC SHUT-DOWNPO EMERGENCY - POWER OFFRPG EMERGENCY - REFRIGERANT PURGESD EMERGENCY - SHUT DOWNSO EMERGENCY - SHUT OFFST EMERGENCY - STOPVS EMERGENCY - VENTILATION STOPVSTART EMERGENCY - VENTILATION START

    PUSH-BUTTON OPERATION

    MODEL DESCRIPTIONST120 Complete break-lens emergency operator station (spare lens included, contacts not included)

    FN1 NEMA 1 all-metal flush-mount boxFN4 NEMA 4 and 12 all-metal flush-mount boxSN1 NEMA 1 all-metal surface-mount boxSN3R NEMA 3R rainproof all-metal surface-mount boxSN4 NEMA 4 and 12 all-metal surface-mount boxSN4XNM NEMA 4X non-metalic surface-mount box

    - Red Break Lens to Release Button model (use normally closed contact to close circuit when button releases)BP1 Red Break Lens - Push Button model, momentary operatorBP2 Red Break Lens - Push Button model, maintained operatorP1 Break Lens - Operate Switch two-position selector switch, maintained both positions, short leverP3 Break Lens - Operate Switch three-position selector switch, maintained all positions, short lever

    BREAK-LENS OPERATION

    LEGENDS - See above

    MODEL DESCRIPTIONST120SL Complete push-pull emergency operator station (contacts not included)

    Notes: Six contact blocks max (2 rows of 3) may be used on each break glass operator station and the -FN1 and -N1 modesl of push-button operation stations . The - model and F model push-button stations can only take three contact blocks (1 row of 3) . All units use normally open contacts to close circuit or normally closed to open circuit (except "Break Glass of Release Button" model) .

    ST120-SN3R-BP2-CS ST120SL-N1-BSST120-FN1-BP2-RPG ST120SL-RP2-VSST120-SN4XNM-PO

    March 2014

    PillaElectricalProducts, Inc.DESCRIPTIONST120 Series Operator Stations offers a means of disconnect to shut down equipment and/or initiate alarms during emergency conditions . Contacts are rated 600V @ 10A AC and 2 .5A DC . All models carry a one-year warranty . UL file is E158147 .

  • NEW!

    91

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

    NEW!DESCRIPTIONThe WPS Series Plate-mounted Operator Stations mount on a single-gang wall box or a standard handy box and come with brushed stainless steel plate . They are rated NEMA 1 for indoor applications . Many options are available for the WPS Series in addition to the models shown on our catalog page .FEATURES Mounted on brushed stainless steel wall plate Order contacts separately for wiring flexibility Hinged lockout lids options Special configurations and labeling are available Single-gang wall or handy box mounting Contacts rated 600V at 10A AC and 2.5A DC One-year warranty UL File E158147

    PLATE MOUNTED OPERATOR STATIONSWPS SERIES

    ORDERING INFORMATIONMODEL DESCRIPTION WPS Wall plate, box mounted emergency operator station (order contacts separately)

    BUTTON STYLE MO Red momentary 40 mm mushroomMP Red maintained 40 mm mushroom (push-pull) labeled Pull to ResetTW Red maintained 40 mm mushroom (push-turn to reset) labeled Turn to ResetKR Red maintained key release 40 mm mushroom with two keys, key required to reset onlyRP1 Red Raise Lid - Push Button padlockable solid lid over momentary flush round push buttonRP2 Red Raise Lid - Push Button padlockable solid lid over maintained flush round push buttonCP1 Red Raise Lid - Push Button padlockable clear lid over momentary flush round push buttonCP2 Red Raise Lid - Push Button padlockable clear lid over maintained flush round push buttonBR Break Lens model with hammer (NC/NO contacts included)

    LEGENDS CS EMERGENCY - CHILLER STOP PO EMERGENCY - POWER OFF BS EMERGENCY - BOILER SHUT-DOWN HS EMERGENCY - HVAC SHUT-DOWN VS EMERGENCY - VENTILATION STOP ST EMERGENCY - STOP SD EMERGENCY - SHUT-DOWNVSTART EMERGENCY - VENTILATION START SO EMERGENCY - SHUT-OFF CLM Clearhinged lockout lid for use with MO, MP, TW, KR 40mm mushroom button DLM Hinged lockout lid for use with MO 40mm mushroom button. Requires lid to be lifted in order to automatically release/extend mushroom device.

    WPS MP VSTART

    Example: WPS-MP-VSTART Wall plate operator station red maintained push-pull button labeled Ventilation Start

    WPS-KR-VS WPS-BR-POWPS-MP-BS-CLM

    WPS-RP2-HSWPS-MO-PO-DLM

    RELATED PRODUCTS PAGEPILCLM Clear cover for MO, MP, TW, KR stations PILNCCB N.C. stackable contact block 103PILNOCB N.O. stackable contact block 103PILRPKEY Replacement key for WPS-KR series, specify model and key number when ordering PILBRLENS Replacement lenses for WPSBR models only (3/pkg)

    Note: Three contact blocks can be used for a depth of 1-5/8" (42 mm) .Three more can be added for a depth of 2-5/8" (67 mm) .

    March 2014

    PillaElectricalProducts, Inc.

  • ALARMS & INDICATION

    92

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

    ORDERING INFORMATION

    POWER CONTROL STATIONSMNST AND MST1 SERIES

    DESCRIPTIONThe MNST and MST1 Series Power Control Stations offer two push-button control for a variety of HVAC and other equipment . It comes with two round push-buttons (one green and one red) and one set of normally open and normally closed contacts .

    FEATURES Models with non-metallic NEMA 4X & 12 enclosures for

    outdoor and wet locations Models with metal NEMA 1 enclosures for indoor and dry

    locations Bold, reflective legends on white enamel aluminum face

    plate Two maintained/interlocked push buttons on MNST models Two momentary/non-interlocked ormomentary/

    noninterloced, push buttons on MST1 models UL listed, File E158147

    Contact Rating 600V, 10A continuous @120 VAC, 0 .5A continuous @24 VDC

    Contact Configuration 1NC, 1 NOOperating Temperature -13 to 158F (-25 to 70C)Storage Temperature -40 to 158F (-40 to 70C)Conduit Connection MNSTxxN1x/MST1xxN1x Knockouts in top, bottom & back for 1/2"

    (1 .27 cm) and 3/4" conduitMounting MNSTx/MST1x Surface mount, external mounting tabs

    top and bottom MNSTxxN1x/MST1xxN1x Surface mount, two mounting holes in the

    back

    Approvals UL Listed file #E158147, cUL ListedEnclosure Rating MNSTx/MST1x NEMA 4X/4/12/3/1, Nonmetallic backbox MNSTxxN1x/MST1xxN1x NEMA 1, Metal backboxDimensions MNSTx/MST1x 4"W x 4"H x 2 .4"D

    (10 .16 x 10 .16 x 6 .09 cm) MNSTxxN1x/MST1xxN1x 4"W x 4"H x 3"D

    (10 .16 x 10 .16 x 7 .62 cm)Weight MNSTx/MST1x 1 lb (0 .45 kg) MNSTxxN1x/MST1xxN1x 2 .5 lbs (1 .13 kg)Warranty 1 year

    SPECIFICATIONS

    MNSTN1SS withPILCLHCOV1 COVER

    MNSTLGSS

    PillaElectricalProducts, Inc.

    ACCESSORIESPILNCMN Additional specialty normally closed contact block for MNST stations onlyPILNOMN Additional specialty normally open contact block for MNST stations onlyPILCLHCOV1PILNCCBPILNOCB

    Clear hinged cover, tamperproofN.C. stackable contact block for MST1 stationsN.O. stackable contact block for MST1 stations

    ModelMNST

    MNST

    (BLANK)LB

    LB

    LCLELFLGLHLPLV

    (BLANK)N1

    N1

    SS

    SS

    OOCI

    Example: MNSTLBN1SS Boiler control station in NEMA 1 metal housing with start and stop pushbuttons

    DescriptionPower control stations, two maintained/interlocked pushbuttons, one set of NO/NC specialty contact blocks included

    MST1 Power control stations, two momentary/non-interlocked pushbuttons, one set of NO/NC contact blocks included

    Main legend "HVAC"Main legend "POWER"Main legend "VENTILATION"

    Default main legend "POWER CONTROL SWITCH"Main legend "BOILER"Main legend "CHILLER"Main legend "EXHAUST FAN"Main legend "FUEL"Main legend "GENERATOR"

    Custom inscriptions on pushbuttons (customer to provide inscription details)

    NEMA 4X/4/12/3 non-metallic grey surface-mount box for outdoor or indoor/wet locationsNEMA 1 metal grey surface-mount box for indoor/dry locations

    "START" and "STOP" pushbuttons"ON" and "OFF" pushbuttons

    March 2014

    ACCESSORIES PAGEPILCLHCOV1 Clear hinged cover for push-pull model and ST120SN4XNM 90,92PILNCCB N.C. stackable contact block for MST1 stations 90-92PILNCMN Additional specialty Normally Closed contact block for MNST stations only PILNOCB N.O. stackable contact block for MST1 Stations 90-92PILNOMN Additional specialty Normally Open contact block for MNST stations only

  • NEW!

    93

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

    Supply Voltage Black 24 VDC @ 10 mA Color 24 VDC @ 35 mAInput Signal 0-5 VDC or 0-10 VDCInput Impedance 400 kAccuracy 0 .1% of scale plus one digitDigit Count VPI-1, VPI-4 3-1/2 digits VPI-3 4-1/2 digitsDigit Size VPI-1, VPI-3C 0 .5" (1 .27 cm) VPI-4 1 .0" (2 .54 cm)Digit Span (VPI-3) 2000 digits (20000 digits)Decimal Point (VPI-3) Three positions or none, Four positions or noneDisplay Color Black, amber, green, redZero Range (VPI-3) -1999 to 1999, -19999 to 19999Operating Humidity 95% non-condensingOperating Temperature 32 to 122F (0 to 50C)Panel Clearance 1 .0" (5 .08 cm)Cutout Requirement VPI-1C 1 .00"H x 2 .40"W (2 .54 x 6 .10 cm) VPI-4 1 .77"H x 3 .62"W (4 .5 x 9 .2 cm)Dimensions VPI-1C, VPI-3C 1 .10"H x 2 .51"W (2 .82 x 6 .38 cm) VPI-4 1 .89"H x 3 .62"W (4 .8 x 9 .6 cm) E (NEMA4X) 6 .0"H x 6 .0"W x 3"D (15 .2 x 15 .2 x 7 .6 cm) WMB 2 .12"H x 3 .12"W x 1 .75"D (5 .4 x 7 .94 x 4 .45 cm)Enclosure Rating NEMA 1, NEMA 4XApprovals RoHSWeight 4 oz (113g)Warranty 1 year

    3-1/2 DIGIT LCD PANEL DISPLAYVPI SERIES

    DESCRIPTIONThe VPI Series is a voltage (0-5V, 0-10V) input 24 VDC powered, 3-1/2 digit display . The VPI Series uses a voltage signal of 0-5 or 0-10 VDC that can be scaled to a span of 2000 digits within a range of -1999 to 1999 . This display also features jumper selectable, built-in engineering units . The VPI-4 offers large, easy to read 1" (2 .54 cm) digits .FEATURES 0-5 or 0-10 VDC input signal 3-1/2 digit, easy to read LCD display (VPI-1, VPI-4) 4-1/2 digit, easy to read LCD display (VPI-3) Available in black amber, green and red digits Snap-in panel mounting NEMA 4 enclosure available Precalibrated before shipping Positive-to-negative indication Jumper selectable engineering unit display of F, C, PSI, %

    Power supply24 VDC

    + - + - + -

    Voltageinput

    * PWR- and SIG- must be externally connected together

    PWR SIG BL

    VPI

    Power connection onlyrequired for amber, green,or red display.

    5V10V

    OFFSET

    5V Span pot10V Span potOffset (ZERO) pot

    WIRING

    SPECIFICATIONS

    ORDERING INFORMATION

    VPI-1C A E-DBL Example: VPI-1C-A-E-DBL Two amber 3-1/2 digit displays mounted in a single enclosure

    MODEL DESCRIPTIONVPI-4 3-1/2 digit panel display*, 1'' (2.54 cm) digitsVPI-1C 3-1/2 digit panel display*, 0.5'' (1.27 cm) digitsVPI-3C 4-1/2 digit panel display*, 0.5'' (1.27 cm) digits 3-1/2 digit display with black digits A 3-1/2 digit display with amber digits G 3-1/2 digit display with green digits R 3-1/2 digit display with red digits No enclosure

    E LCD panel display with NEMA 4X enclosure (VPI-1C and VPI-3C only) WMB LCD panel display with small enclosure (VPI-1C and VPI-3C only) E-DBL Two LCD panel displays in one NEMA 4X enclosure (VPI-1C and VPI-3C only)

    VPI-1-C-WMB

    VPI-4VPI-1-C-G

    (typical panel mount)

    VPI-1-C-R-E VPI-1-C-R-E-DBLAPPLICATION Temperature Humidity Pressure

    Gallons per minute Voltage Kilowatt demand

    Displays are custom calibrated at no charge and require specification of input scale (VDC), range, engineering units, and decimal point placement .

    RELATED PRODUCTS PAGEDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995DCPA-1.2 Power supply, 120 VAC In to 24 VAC/24 VDC OutGP-3420 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm) 93,97-99GP-3430 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm) 93,97-99

  • ALARMS & INDICATION

    94

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

    Supply Voltage 4 to 30 VDC @ 35 mA Input Signal 0/2-10 VDC, 4-20mA (with resistor)

    0-40 VDC maxInput Impedance 110 mA @ 5 VDCWire Type Screw terminals, 16 to 26 AWGAccuracy 0 .05% typical, 0 .1% maximumDisplay Type SGD-24 2 .4 inch diagonal 320 x 240 pixels,

    16-bit color SGD-28 2 .8 inch diagonal 320 x 240 pixels,

    16-bit colorInterface Compatible with Windows XP, 2000,

    Vista, Windows 7, mini USB cable connection

    Sample Intervals 3 samples per secondOperating Temperature 32 to 104F (0 to 40C)Panel Cutout SGD-24 1 .81"H x 2 .91"W (4 .60 x 7 .40 cm) 0 .11"

    (3 mm) maximum panel thickness SGD-28 2 .15"H x 3 .43"W (5 .45 x 8 .70 cm)

    0 .11" (3 mm) maximum panel thicknessDimensions SGD-24 1 .9"H x 3 .0"W x 0 .7"D

    (4 .8 x 7 .6 x 1 .8 cm) SGD-28 2 .2"H x 3 .5"W x 0 .8"D

    (5 .7 x 8 .9 x 1 .9 cm) NEMA 4X enclosure 6 .0"H x 6 .0"W x 3 .0"D

    (15 .2 x 15 .2 x 7 .6 cm)Enclosure Options NEMA 1 standard NEMA 4X optional Additional Specifications Meter choices- Bar graph, analog

    needle, digital readout, combinationsApprovals CE, RoHSWeight SGD-24 0 .11 lb (0 .05 kg) SGD-28 0 .14 lb (0 .06 kg)Warranty 1 year

    PANELPILOT SMART GRAPHICAL DISPLAYSGD-24, -28

    DESCRIPTIONThe PanelPilot Smart Graphics Display is a configurable panel-mount volt meter with selectable graph colors, input signal scales, and meter display types . It can be used to display any proportional control or transmitter signal represented by a voltage span within 0 to 40 VDC . It is easily and quickly field-configured using simple software, via a USB cable, or is available preconfigured from Kele . It has a customizable splash screen and comes in a 2 .4" or 2 .8" screen size . A NEMA 4X enclosure is also available which can house one or two displays, preassembled at Kele or separately available for field installation .

    FEATURES 2.4" or 2.8" color TFT screen for high visibility Free PanelPilot software saves money Simple USB cable connection for quick setup 6 standard meter types, selectable colors, scales, and

    labels for display flexibility Splash screen accepts common picture files and

    allows customization Snap-in panel mount for fast installation NEMA 4X enclosure option with single or double

    display mounting

    APPLICATION Temperature Humidity Pressure Air quality Valve or damper position Air or water flow Water level Light level Motor speed Any 4-20 mA or 0-10 VDC transmitter signal

    SPECIFICATIONS

    SGD-28-M-C-E

    METER CHOICES

    SGD-28-M

    Digital Analog Analog & Digital Bar Graph Bar Graph Meter Digital & Bar Graph Meter

  • NEW!

    95

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014

    WIRING

    PANELPILOT SMART GRAPHICAL DISPLAYSGD-24, -28

    24 VDCPower Supply

    1-5 V

    BAS Input 4-20 mA +

    -

    +

    +

    -

    + -

    4-20 mALoop-powered

    Transmitter

    -

    +

    4-20 mA Wiring

    1

    1 = IN2 Input 2 (40 VDC max) (not used)2 = IN1 Input 1 (40 VDC max)3 = OV Common4 = v+ Power (4-30 VDC)

    +2 3 4

    - *24 VDC POWER SUPPLY MUST BE FLOATING (NOT GROUNDED TO

    BAS COMMON)*

    250*

    *Order Separately

    *Meter must be configured for 1-5 V input for 4-20 mA input signal, when

    using the 250 resistor. If using a 500 resistor, configure the meter for 2-10 V.

    24 VDCPower Supply

    BAS Input 0-10V

    -

    +

    -

    + -

    0-10 VDCTransmitter+

    -

    +

    0-10 VDC Wiring

    +1 2 3 4

    +

    +

    -SIGPWR

    -

    ORDERING INFORMATION

    ACCESSORIESSFP66-258E Panel for SGD-24, singleSFP66-258F Panel for SGD-24, doubleSFP66-258C Panel for SGD-28, singleSFP66-258D Panel for SGD-28, doubleUSB-A-MF USB Cable Type A TO Mini BP6063C-P258 6x6x3 NEMA4X Encl Clear Hinge Cover w/ SOPK Kit250R-3-1 250 OHM 3 WATT 1% Resistor Long Leads

    MODEL DESCRIPTIONSGD-24-M Smart Graphics Display, 2.4 inchSGD-24-M-C Smart Graphics Display, 2.4 inch, custom calibratedSGD-24-M-C-E Smart Graphics Display, 2.4 inch, calibrated, enclosureSGD-24-M-C-XK Smart Display, 2.4 inch, calibrated, custom graphicSGD-24-M-C-XK-E Smart Display, 2.4 inch, calibrated, custom graphic, enclosureSGD-24-M-CEDBL Smart Display, 2.4 inch, calibrated, enclosure, doubleSGD-24-MCXKEDBL Smart Display, 2.4 inch, calibrated, custom graphic, enclosure, doubleSGD-28-M Smart Graphics Display, 2.8 inchSGD-28-M-C Smart Graphics Display, 2.8 inch, custom calibratedSGD-28-M-C-E Smart Graphics Display, 2.8 inch, calibrated, enclosureSGD-28-M-C-XK Smart Display, 2.8 inch, calibrated, custom graphicSGD-28-M-C-XK-E Smart Display, 2.8 inch, calibrated, custom graphic, enclosureSGD-28-M-CEDBL Smart Display, 2.8 inch, calibrated, enclosure, doubleSGD-28-MCXKEDBL Smart Display, 2.8 inch, calibrated, custom graphic, enclosure, double

    Note: Custom Calibrated Panels, require completion of the panel configuration worksheet . Work-sheet available on Kele website www .kele .com

    RELATED PRODUCTSDCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUTDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT

    March 2014

  • ALARMS & INDICATION

    96

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014March 2014

    Supply Voltage 90-240 VAC, 12 VA / 10 .5 - 30 VAC/VDC 6VAInput Current 4-20 mA, 300Input Voltage DC 0-5 VDC, 0-10 VDC, 1 MInput Monitor DC power (no offset, 10 M 0-200 mVDC,

    0-2 VDC, 0-20 VDCAccuracy 1% full scale plus 1 count Digit Span 3-1/2 digitDecimal Point Off, DP1, DP2, DP3

    (1999, 199 .9, 19 .99, 1 .999)Display Color Red, green, blueDisplay Size 2 .3" (5 .8 cm)Display Type Seven-segment LEDRange -1999 to 1999Calibration Zero and span, non-interactiveOperating Humidity 5-95% RH non-condensingOperating Temperature 14 to 122F (-10 to 50C)Cutout Requirement 4 .0"H x 10 .4"W x 2 .0"D (10 .0 x 26 .4 x 5 .0 cm)Dimensions 4 .2"H x 10 .6"W x 2 .2"D (10 .6 x 27 .0 x 5 .5 cm)Enclosure Options NEMA 1, aluminum and plasticMounting Panel: Steel U-bracket Wall/ceiling: Steel swivel bracketApprovals RoHSWeight 2 .8 lb (1 .3 kg)Warranty 1 year

    KELE BIG DISPLAY READOUT, 3-1/2 DIGIT LED, RED/BLUE/GREENBDR SERIES

    DESCRIPTIONThe BDR Big Display Readout has large 2 .3" size LED digits . It provides 3-1/2 digits and comes in three bright LED colors: red, green or blue . The BDR has a selectable decimal point position and accommodates negative sign readouts . The readouts are in linear proportion to the 4-20 mA, 0-10 VDC, 0-5VDC signal inputs or a voltage monitor input from 0-20VDC . These displays are easy to field calibrate with non-interactive zero and span pots as well as free pre-calibration service from Kele at time of order .FEATURES Large 2.3" (5.8 cm) digital display LED colors in red, green or blue 3-1/2 digit with negative signal as needed Standard signal inputs: 4-20 mA, 0-10 VDC, 0-5 VDC Wall, ceiling or panel mount Non-interactive zero and span pots Pre-calibration

    Calibration pots(use varies withsource; seeinstallationmanual)

    SPAN

    IN IN+DCV

    Power supply monitor0-(0.2, 2, or 20) VDC

    Voltage signal in

    LPI = Current signalVPI = Voltage signalDCV = Voltage monitorDP = Decimal point placementLPI OFFSET = Negative () sign Choice for V or I signal

    *LPI function disables RANGES switch

    0-5 or 0-10 VDC

    Current signal in4-20 mA

    VPI

    VPI

    DCV

    RANGES

    200m

    V20

    0mV

    2V5V

    20V

    10V

    INPUT

    LPIAC POWER90V-250V

    SIG SIG+ SIG SIG+ AC GNDAC

    DCV 5V 10VLPIVPI LPI

    OFFSET

    FUNCTION DECIMAL

    LPI

    VPIDCV

    DP1

    DP2DP3

    +

    *

    *

    SPAN SPANSPAN

    SPAN OR ZERO ADJ.

    ZERO ZERO

    BDR-999-[R/G/B]-2410.5 to 30 VAC/VDC

    WIRING

    SPECIFICATIONS

    BDR-G

    BDR-B

    Mounting Brackets included

    ORDERING INFORMATION

    MODEL DESCRIPTIONBDR-999-R-24 Red LED 3-1/2 digit display, 2.3" (5.8 cm) high 24 VAC/VDCBDR-999-G-24 Green LED 3-1/2 digit display, 2.3" (5.8 cm) high 24 VAC/VDCBDR-999-B-24 Blue LED 3-1/2 digit display, 2.3" (5.8 cm) high 24 VAC/VDCBDR-999-R-120 Red LED 3-1/2 digit display, 2.3" (5.8 cm) high 120 VACBDR-999-G-120 Green LED 3-1/2 digit display, 2.3" (5.8 cm) high 120 VACBDR-999-B-120 Blue LED 3-1/2 digit display, 2.3" (5.8 cm) high 120 VAC

    Displays are custom calibrated at no charge and require specification of input scale (mA, VDC), range, engineering units, and decimal point placement .

    BDR-R

    RELATED PRODUCTSDCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUTDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT

  • NEW!

    97

    ALARMS & INDICATIONALARM

    S & INDICATION

    2

    WE MAKE IT EASY. kele.com 888-397-5353 USAMarch 2014March 2014

    DESCRIPTIONModel LPI-1C is a loop-powered indicator featuring a large 3-1/2 digit LCD display with black digits . The Model LPI-1C displays engineering units of F, C, PSI, %, or no engineering units if desired . It is directly powered by the 4-20 mA signal and scaled to specifications . FEATURES Indication of 4-20 mA signal in desired scale 3-1/2 digit LCD display Snap-in panel mounting Easy-to-read digits NEMA 4X enclosure available Precalibrated for desired range Negative-to-positive indication Jumper-selectable engineering unit display

    Powersupply

    Sensor/transmitter

    BAS inputor other

    4-20 mA load

    -

    + -

    +

    ZERO

    SPAN

    + - Factory calibrated(no field calibration

    needed)

    - +

    Back of display unit

    Board unitFCPSI%

    Connector pins Engineering unit jumpersUnit selected displays tothe right of display reading.

    4-20 mA

    SIGConnect the LPI-1C indicator in series with the 4-20 mA current loop to be measured.

    WIRING

    APPLICATION Temperature Humidity Pressure Differential or static pressure Kilowatt demand

    3-1/2 DIGIT LCD PANEL DISPLAYLPI-1C

    SPECIFICATIONS

    ORDERING INFORMATION

    LPI-1C E-DBL Example: LPI-1C-E-DBL Two LPI-1C displays mounted in a single enclosure

    MODEL DESCRIPTIONLPI-1C 3-1/2 digit LCD panel display with black digits* No enclosure E 3-1/2 digit LCD panel display with NEMA 4X enclosure WMB 3-1/2 digit LCD panel display with small enclosure E-DBL Two 3-1/2 digit LCD panel displays in one NEMA 4X enclosure

    Gallons per minute Voltage Current Many other 4-20 mA applications

    LPI-1C-WMB

    Input Signal 4-20 mA loop-poweredInput Impedance 300 nominal @ 24 VDCAccuracy 0 .1% of scaleDigit Size 0 .5" (1 .27 cm)Decimal Point Three positions or none (1 .0 .0 .0)Display Color BlackRange -1999 to 1999Operating Humidity 95% non-condensingOperating Temperature 32 to 122F (0 to 50C)Panel Clearance 1 .97" (5 .00 cm)Cutout Requirement 1 .00" H x 2 .40" W (2 .54 x 6 .10 cm)Dimensions Display 1 .11" H x 2 .51" W (2 .82 x 6 .38 cm) E (NEMA 4X) 6 .0"H x 6 .0"W x 3 .0"D

    (15 .2 x 15 .2 x 7 .62 cm) WMB 2 .12''H x 3 .12''W x 1 .75''D

    (5 .4 x 7 .94 x 4 .45 cm)Approvals RoHSWeight 0 .14 lb (0 .06 kg) (display only)Warranty 1 year

    LPI-1C (typical panel mount)

    LPI-1C-E LPI-1C-E-DBL

    Displays are custom calibrated at no charge and require specification of input scale (mA), range, engineering units, and decimal point placement .

    RELATED PRODUCTS PAGEDCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT DCPA-1.2 Power supply, 120 VAC In to 24 VAC/24 VDC Out GP-3420 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm) 93,97-99GP-3430 LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm) 93,97-99

  • ALARMS & INDICATION

    98

    ALAR

    MS &

    INDI

    CATI

    ON

    2

    WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.kele.com888-397-5353 USA March 2014

    NEW!

    March 2014

    Supply Voltage 24 VDC @ 35 mAInput Signal 4-20 mA loop poweredInput Impedance 300 nominal @ 24 VDCAccuracy 0 .1% of scaleDigit Size 0 .5" (1 .27 cm)Decimal Point Three positions or none (1 .0 .0 .0)Display Color AmberDisplay Size 0 .5" (1 .27 cm)Range -1999 to 1999Operating Humidity 95% non-condensingOperating Temperature 32 to 122F (0 to 50C)Panel Clearance 1 .97" (5 .00 cm)Cutout Requirement 1 .00"H x 2 .40"W (2 .54 x 6 .10 cm)Dimensions Display 1 .11"H x 2 .51"W (2 .82 x 6 .38 cm) E (NEMA 4x) 6 .0"H x 6 .0"W x 3 .0"D (15 .2 x 15 .2 x 7 .62 cm) WMB 2 .12''H x 3 .12''W x 1 .75''D (5 .4 x 7 .94 x 4 .45 cm) DBL 6 .0"H x 6 .0"W x 3 .0"D (15 .2 x 15 .2 x 7 .62 cm) Approvals RoHSWeight 0 .14 lb (0 .06 kg) (Display only)Warranty 1 year

    3-1/2 DIGIT LCD AMBER / GREEN / RED PANEL DISPLAYLPI-1C-A, LPI-1C-G, LPI-1C-R

    DESCRIPTIONModels LPI-1CA, G, and R are 4-20 mA, 24 VDC-powered, brightly lit 3-1/2 digit color LCD displays, available with amber, green, or red digits . Models LPI-1CA, G, and R also feature jumper-selectable built-in engineering units of F, C, PSI, %, or no units . The same 24 VDC power supply can be used to provide power to the 4-20 mA loop and the display .FEATURES Indication of 4-20 mA signal in desired scale Bright 3-1/2 digit LCD display Available in amber, green, and red Snap-in panel mounting Easy-to-read digits NEMA 4X enclosure available Precalibrated for desired range Negative-to-positive indication Jumper selectable engineering unit display

    Powersupply

    24 VDC

    Sensor/transmitter

    BAS input orother 4-20 mA

    load

    -

    + -

    +

    ZERO

    SPAN

    + - + -Factory calibrated

    (no field calibration needed)

    - +

    Back of display unit

    Board unit

    FCPSI%

    Connector pins Engineering unit jumpersUnit selected displaysto the right of displayreading.

    SIG B/L

    4-20 mA

    Connect the LPI-1C indicator in series with the 4-20 mA current loop to be measured.

    WIRING

    APPLICATION Temperature Humidity Pressure

    SPECIFICATIONS

    ORDERING INFORMATION

    LPI-1C-G-WMB LPI-1C-G(typical panel mount)

    Differential or static pressure Kilowatt demand Gallons per minute Voltage Current Many other 4-20 mA applications

    LPI-1C-R-E LPI-1C-R-E-DBL

    LPI-1C-A E-DBL Example: LPI-1C-A-E-DBL Two amber 3-1/2 digit LCD displays mounted in single enclosure

    MODEL DESCRIPTIONLPI-1C-A 3-1/2 digit LCD with amber digits*LPI-1C-G 3-1/2 digit LCD with green digits*LPI-1C-R 3-1/2 digit LCD with red digits* No enclosure E 3-1/2 digit LCD panel display with NEMA 4X enclosure WMB 3-1/2 digit LCD panel display with small enclosure E-DBL Two 3-1/2 digit LCD panel displays in one NEMA 4X enclosure

    Displays are custom calibrated at no charge and require specification of input scale (mA)